HomeMy WebLinkAboutC014.0 SWPP BMP DetailsCIVIL SEAL12345CBAJOB NO.ISSUED FOR:REVIEWRECORDCONSTRUCTIONPERMITREV.DATE DESCRIPTION
A 10/10/19 ISSUED FOR REVIEW 70% SET
520 South Main Street, Suite 2531Akron, OH 44311330.572.2100 Fax: 330.572.2102B 11/19/19 ISSUED FOR REVIEW 90% SET
---------10/10/19CARMEL, IN 46033
12120 BROOKSHIRE PKWY
BROOKSHIRE GOLF CLUB
2019706.07DESIGNERPROJECT MANAGERTTPLJBDrawing Name: O:\2019\2019706 INDY MISC\07 Brookshire Golf Club City Of Carmel\DWG\CD\Brookshire Golf Club CDs.dwgNovember 19, 2019 3:43 PM - lbarker
C-5BEST MANAGEMENT
PRACTICES, EROSION
CONTROL DETAILS & NOTES 3'-0" MIN.1 ROW OF STAPLES,12" O.C.DO NOT NEED TO TRENCH BLANKET IN IF IT CAN BE EXTENDEDA MINIMUM OF 3'-0" OVER THE CREST OF THE SLOPE.STAPLE 12" O.C. ALONGBOTTOM OF BLANKETAT THE END OF SLOPESTAPLE 12" O.C. ALONGBLANKET AT SLOPECHANGE3'-0" MIN.END SEAM OF BLANKETS OVERLAP 2"-4".PLACE STAPLES, ONE ON EACH CORNER OFBLANKET, 12" O.C. ALONG BLANKET ENDTHROUGH STITCHING ON BOTH BLANKETS.UPSLOPE BLANKET LAPS OVER DOWNSLOPEBLANKETS IN A SHINGLE AFFECT.EXTEND BLANKET A MINIMUM OF 3'-0"OVER CREST OF SLOPE, SEE DETAIL 2.TRENCHING NEEDED IF A MINIMUMOF 3'-0" IS NOT AVAILABLE AT THECREST OF SLOPE OR IF OVERLANDFLOW IS ANTICIPATED FROM UPLANDAREAS, SEE DETAILS 3 & 4FOR END ROLLOVERLAP, SEEDETAIL 5BLANKET TO EXTEND AMINIMUM OF 3'-0"BEYOND TOE OF SLOPE.FOR BOTTOM OF SLOPETERMINATION, SEEDETAIL 6SIDE SEAM OVERLAP,SEE DETAIL 7SOIL PILEFROM TRENCHTRENCH APPROX.10" WIDE x 8" DEEP18"2 ROWS OF STAPLES,STAGGERED, 6" O.C.,EA. DIR.1 ROW OF STAPLES,12" O.C.SLOPE TOPROTECTSOIL FILLEDFROM SOIL PILE2 ROWS OF STAPLES4" APART, STAGGERED,6" O.C., STAPLES TO BEPLACED CLOSE TO EDGEOF BLANKETSTEP 1STEP 2TOP OF BLANKET1 ROW OF STAPLES,12" O.C.2 ROWS OF STAPLES,STAGGERED, 6" O.C.,EA. DIR.SOIL PILEFROM TRENCHSLOPE TOPROTECTSOIL FILLEDFROM SOIL PILE2 ROWS OF STAPLES,STAGGERED, 6" O.C.,EA. DIR.STEP 1STEP 2TRENCH APPROX.10" WIDE x 8" DEEPSTAPLES ARE THROUGHOUTER MOST STITCHON BOTH BLANKETS.BLANKETOVERLAP2" - 4"2SCALE: N.T.S.C-5SLOPE CREST ANCHORMETHOD "A" (NO TRENCH)3SCALE: N.T.S.C-5SLOPE TRENCHINGMETHOD "B"7SCALE: N.T.S.C-5SIDE SEAM OVERLAPSTAPLE DETAIL4SCALE: N.T.S.C-5SLOPE TRENCHINGMETHOD "C"6SCALE: N.T.S.C-5BOTTOM OF SLOPETERMINATION5SCALE: N.T.S.C-5END ROLL OVERLAP1SCALE: N.T.S.C-5SLOPE DETAILNOTES:1. STAPLE PATTERNS ARE DEPENDENT ON SITE CONDITIONS. SEE CURLEX NETFREE STAPLE PATTERN GUIDE FOR DETAILS.2. E-STAPLE
MAY BE USED IN PLACE OF WIRE STAPLES.NOTES:1.STAPLE PATTERNS ARE DEPENDENT ONSITE CONDITIONS. SEE CURLEX NETFREESTAPLE PATTERN GUIDE FOR DETAILS.2.E-STAPLE MAY BE USED IN PLACE OF WIRESTAPLES.NOTES:1.STAPLE PATTERNS ARE DEPENDENT ONSITE CONDIT
IONS. SEE CURLEX NETFREESTAPLE PATTERN GUIDE FOR DETAILS
.2.E-STAPLE MAY BE USED IN PLACE OF WIRESTAPLES.