Loading...
HomeMy WebLinkAbout07040110 Site Plan .... ~~ Schneider The Schneider Corporation 8901 0tiJ Avenue Historic ,fort Harrison lndiallapolls, IIldlana 46216-1037 317-B26-71oo 317-82B-7200 FAX KDglneeriD& SUneyiag Land.scape Archlteet.ure GIll.US Goolo.,. This Plot Plan Prepared For: R.H. of Indiana Lot # 155 , containing 7,800 S.F.:!:, in Stanford Park Section # 2A INSlR. # 200600014565 PC 4, Slide 42 Clay Twp, HamDton County Sec 29, TI8N, R3E 3387 Modesto Lone (50' R/W) Camnel, IN 46074 Prepared Date: 04/05/07: By: AMA Proposed Bu)'lll'(s): Dong Xie Plot PIon Legend [QQQ]] Proposed Grades ODO.O Existing Grades _000.0-- Contour Grode * Approx. Lateral Location - I - Sanitary Sewer lines - ,,- Storm Sewer lines - 'oJ ~ Water Service Lines - - - - - - - Sub..Surfoce Drain lines . Manhole (Sanllary or Storm) 41 Beehive Inlet (Storm) IIIlI Curb Inlet (Storm) D End Section (Storm) ... Fire Hydrant - 0 0 0 _ 0 0 0 - Flow Line of swole Building Line (Bl I BSl) - - - - - - - Easement line Community Restrictions: Side Yard =3' min. Reor Yard = N/A Aggregate = 6 (B.H.) Note: Sanitary Sewer Tap of Casting infarmatian Upstream Manhole, TC=917.30 per plan Downstream Manhole, TC=915.26 per record drawing R.H. of Indiana Finished Floor Elevation Information Pad Grade = 915.9 per plan Pad Grade + 0.7' = Garage FFt (916.6) Garage FFE + 1.5' = Residentlai FFE (918.1) Residenliai FFE - 9.0' = Basement FfE (909.1 ) Note: The contractor is to maintain a minimum distance of ten feet (10') between the sanitry sewer and water line laterals. Note: The garage finished floor elevation It is 1.4' above the curb at the drive, per plan. STR.# 729 TC-91~26 PERR!:CORO ORA\\1 1 _o.S.E. - bO.UU ~ Ground Cover Calculations: Orlve = 501 SH Public Walk =240 SFt Private Waik = 52 SF t Hydraseeding =3,061 SFt Sod = 313 SH, from Rear of residence. Optional Sod Package Hydraseeding =975 SFt Add!. Sod Pkg.= 232 SH, to Rear easement. Nate: This drawing is based on construction pIons or record drawings, and is not based upon a field survey. The Schneider Corporation does not warrant the accuracy or sufficiency of this information. Contractors should verify existing conditions prior to any construction. Any discrepancy found on this drawing should be reported to The Schneider Corporation immediately; foiling to do so results in the contractors assumption of all liability. Note: Per Carmel zoning ordinance 26.1.1 : The residential district limits height to twenty-five feet (25'), however a dwelling may be increased in height to thirty-five feet (35') provided the side and rear yords ore increased on additional one foot (1') for each one foot (f) the structure exceeds the first twenty-five feet (25') in height. Detail of Ground/ Storm Water flow pattern for individual lots. Lot # 155 Vb07.0071425 o ~ =~= I \ I I '01 1 I \ ' , , Note: Builder to ensure positive drainage away from structure(s). o Assumed North Scale: 1- = 30' - t STR.# 736 TC=917.30 PER PLAN . i: ~ MODE::O _lANE .. 5' WAlK Sidewalk to be placed l' from property line, 4' from bock of curb, per plan. 65.00 .. 1915.31 1915.6 I 25' G.B.L 22.5' B.L 36.0' 26.Q' * 20' D.&U.E. 22.5' Bol"\ ,.=.=-, .B.U--- I 16' ORI", -~ C> C> ci N 9.0' 2. 25 to T\\\) CAR 8 GARAGE . POR SUMP 19.63 OPUMP BSMNT/ i!; i<t CRAI\\. <D .0 ~O en C> ci N SOD ~ STERUNG A i<t FRM&lASY R!:SOENCl: 40.00' 7X5 OEC!< RE~SON #' RE~SED BASEMENT m OHo-07 AMA I 1 I~ (2ETI I;;; .2.6 1- .....2Pll0N~ ~ PACKAGE 15' O.E. .7.6' ~ TYPICAL SWALE SECllON Will 'i5,00' 65.00' 16.0' SOD . ~~9~':~0 PER PlAN -=--r. t I I 1 I Note: The basement e/evotion, depicted hereon, has been determined and based on the pod grades and/or contours token from t~e construction pIons for this subdivision,1 Unless stated, no information about f1uctuotillg water tables. soU conditions, or soil t)pes has been pro.,;ded or stated on :laid plans. Thisi lot ill located necr 0 body of water. lot or ~oQ conditiOns moy require thot the basement floor elevation be held 2 foot above normal pool elevation. Site investigation may be needed if water Is encountered during the excavotion process or if other known water elevotlon or soils conditions ore present. Investigation and any remedial procedures is at the discretion of the builder to determine and toke appropriate steps of action. If any ground water Is encountered during excavotion the bunderis et'lcouragedto contoctThe SchneIder Corporation to discuss possible courses of action. "' ci '" in Note: Sump pump(s) to be piaced by builder os needed. FLOOD HAZARD STATEMENT CERnFICA nON ,\1\\\1\\11111111/1/1/1/111. #\1'\ L C, Y/~ #" ~ ,.......:......:1'.0.:% ~~..~G\S T€'I?~.......A~ g~....~ No 0.....;..0% 2:i:' .'::::. I ( S0303 ) J ~ \ STATE OF .... fi ~ ("" ..... I '" ..... (\ ~ ~..j4fj"'::S.~U.'.fR...ti.;:\~~ ~;, 'i \. 'c-.\~~ WIIIIIJIJIIIIII\\\\\\\\\\\ ~ l.ffi 55.00' 15' O.E. 1914.5 I This drawing is not intended to be represented as a retracement or original boundary survey, 0 route survey, or a Surveyor Location Report. Flood Hazard Statement: The accuracy of any flood hazard data shown on this report is subject to map scale uncertainty and to any other uncertainty in location or elevation on the referenced flood insurance rate map. ALL of the within described land DOES NOT LIE within that special flood hazard zone A as said land plots by scale on flood insurance rate map # 18057 020SF for City of Carmel, Indiana (maps dated February 19. 2003). SGNA lURE : OAT[: ~GNA lURE REPRESENTS CONRRMA TION OF RECl:IPT Of PLOT PLAN BY CUSTOMER.