Loading...
HomeMy WebLinkAbout2017.02968.CE.C600.SD-C601.SITE DETAILS™ Phone (888) 344-9044 Fax (423) 826-2112 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 STORMWATER TREATMENT SOLUTIONS www.aquashieldinc.com Aqua-Swirl Concentrator Model AS-7 BYP PCS Standard Detail AS-7 PCS STD 01/06/15 Scale: Drawn By: Document: Date: JCW 1:30 U.S. Patent No. 6524473 and other Patent Pending 5 3/8" [137 mm] 5/8" [15 mm] 1 3/16" [30 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Soil 1 3/16" [30 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Soil Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Riser Frame Cover 57 5/8" [1463 mm] Min. 14 3/8" [366 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Concrete Concrete 9 5/8" [244 mm] Gravel Backfill Gravel Backfill 5 3/8"Cover Frame 1" [25 mm] Thick Expansion Joint Material30" [762 mm] Riser #4 [13 mm] Rebar @ 6" [152 mm] Each Way 16 13/16"5/8" 3,000 psi [20 MPa] (min) Concrete Manhole Frame & Cover Detail For Traffic Loading Areas NTS If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1-inch [25 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Backfill (90% Proctor Density) 57 5/8" Internal Baffles Slide riser over top ring and bolt in 4 places Riser 114" [2896 mm] to 122" [3099 mm] Swirl Inlet/Outlet Grade (Rim) 30" [762 mm] Rim elevations to match finished grade.Manhole Frame and Cover by Manufacturer. (See Details) VariesVaries 68" [1727 mm] STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Bedding Undisturbed Soil Backfill 6" [152 mm] 18" [457 mm] Section A-A Plan View 96" [2438 mm] 96" [2438 mm] Outlet A Internal Baffles Octagonal Base Plate Pipe coupling by Contractor. 12" [305 mm] long Stub-out by Manufacturer. Ø84" [Ø2134 mm] 5" [127 mm] MH Frame Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System A Inlet 42" [1067 mm] PCS Max * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. ** Orientation may vary from 90°, 180°, or custom angles to meet site conditions. Note: As an alternative, 42-inch OD, HS-20/25 rated precast concrete rings may be substituted. 14-inch thickness must be maintained. 180°**PLOT DATE: 6/25/2020 8:40 AMPLOT SCALE: 1:2.5849EDIT DATE: 6/25/2020EDITED BY: NHORGANDRAWING FILE: P:\2017\02968\D. Drawings\Civil\Construction Documents\2017.02968.CE.C600.SD.dwg7260 Shadeland Station | Indianapolis, Indiana 46256 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com Project Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: REVISION SCHEDULE NO.DESCRIPTION DATE 08/09/2019 PERMITTING 2017.02968 CARMEL MEDICAL ARTS PAVILION 12174 N. MERIDIAN ST. CARMEL, INDIANA 111 Congressional Blvd. , Suite 300 Carmel, Indiana 46032 C601 SITE DETAILS