INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY
ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR
WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR
EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES
SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND
WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE
OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY
ALL CONSTRUCTION.
THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES,
SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND
CAUTION !!
Know what's below.
before you dig.Call
R
Call 811 or 1-800-382-5544 Before You Begin Any Digging Project.
Call 48 hours or 2 working days before you dig.
It's Fast, It's Easy and It's the Law in the state of Indiana! SU1.0
SITE UTILITY PLAN
CONSULTANT
CARMEL CLAY SCHOOLS
WWW.FHAI.COM
ARCHITECT
317-848-0966
350 E NEW YORK ST# 300, INDIANAPOLIS, IN 46204
COPYRIGHT 2021 BY FANNING/HOWEY ASSOCIATES, INC.
5201 EAST MAIN STREET
CARMEL, INDIANA
TAC SUBMITTAL
REV.
NO.DESCRIPTION DATE
ISSUE FOR BID/TAC REVIEW 03/15/20210
PROJECT NUMBER: 220144.00
PROJECT ISSUE DATE: MARCH 15, 2021
DRAWN BY: DBS
WWW.TLF-ENGINEERS.COM317-334-1500
3901 W 86TH ST #200, INDIANAPOLIS, IN 46268
EDUCATIONAL
SERVICES CENTER
ADDITION AND
REMODELING
ADDENDUM #1 04/19/20211
CITY COMMENTS 08/19/20212
1.SEE DRAWING GD0.01 FOR GENERAL NOTES AND ADDITIONAL LEGEND.
2.TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY
CIVIL ENVIRONMENTAL CONSULTANTS, INC. THE ENGINEER MAKES NO
GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH
UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED.
3.CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA
INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR
TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE
ENGINEER.
4.SEE SHEET G2.0 FOR GRADING PLAN.
5.THE PROPOSED STORM SEWER SYSTEM FOR THIS PROJECT WILL BE PRIVATE
OWNED.
6.NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED
STORM WATER MANAGEMENT PERMIT.
7.UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE
RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR
ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT
SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY.
EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF
PROPOSED RIGHT-OF-WAY LINE.
8.DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE
SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE
CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY
PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING
CONDITION OF THE RIGHT-OF-WAY.
GENERAL NOTES UTILITY KEYNOTES
1.6" PVC ROOF DRAIN PIPE @ 1.00% MIN. SLOPE - SEE DETAIL
B/SU2.0
2.PVC STORM STORM SEWER CLEANOUT - SEE DETAIL A/SU2.0
3.CONCRETE SLOPED HEADWALL - SEE DETAIL C/SU2.0
4.RELOCATE OR PROTECT IN PLACE EXISTING UNDERGROUND
TELEPHONE LINES (SEE SITE ELECTRICAL PLAN)
5.PROTECT EXISTING UNDERGROUND ELECTRIC TO REMAIN
6.CONTRACTOR TO COORDINATE RESET/ADJUST TO GRADE
OF FIBER OPTIC PULL BOXES WITH UTILITY COMPANY
7.6" PERFORATED PVC SUBSURFACE DRAIN THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND
AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION
PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL BE PERMITTED DUE TO
SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL
REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE
CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN
ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A
REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF
PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS
GENERATING VELOCITIES OF 2.5 FPS OR LESS, OR 10 FPS OR GREATER (AT FULL
FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF
CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED
AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE
COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL.
STORM SEWER NOTE
30 9003060
UTILITY LEGEND
APPROXIMATE LIMITS OF CONSTRUCTION
SUBSURFACE DRAIN