HomeMy WebLinkAboutChick-Fil-A - US 421 Full SetPLANNING & ZONING: CITY OF CARMEL (317) 571-2417 CONTACT - RACHEL KEESLING rkeesling@carmel.in.gov BUILDING:CITY OF CARMEL (317) 571-2489 CONTACT - NICK MISHLER nmishler@carmel.in.gov FIRE DEPARTMENT:CITY OF CARMEL FIRE DEPARTMENT (317) 571-2612 CONTACT - CHRIS ELLISON cellison@carmel.in.gov SANITARY SEWER:TRICO REGIONAL SEWER FACILITY (317) 844-9200 CONTACT - RYAN HARTMAN ryan.hartman@trico.eco STORM SEWER:CITY OF CARMEL (317) 571-2441 CONTACT - ALEX JORDAN ajordan@carmel.in.gov WATER SERVICE:CITY OF CARMEL (317) 571-2443 CONTACT - JOHN DUFFY jduffy@carmel.in.gov ELECTRIC SERVICE:AES INDIANA (317) 261-5047 CONTACT - RODNEY JOHNSON rodney.johnson@aes.com TELEPHONE SERVICE: AT&T (317) 403-6673 CONTACT - WENDY NOBLE w1807s@att.com GAS SERVICE:VECTREN (317) 776-5590 CONTACT - CHAD MILLER chad.r.miller@centerpointenergy.com ROADWAY:CITY OF CARMEL (317) 571-2677 CONTACT - AARON HOOVER ahoover@carmel.in.gov INDIANA DEPARTMENT OF TRANSPORTATION (765) 675-7402 EXT. 6 CONTACT - SANDY LANDRUM Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSION AL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDI AN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-000 COVER SHEET L O C A T I O N M A P WEST CARMEL 9965 N. MICHIGAN ROAD CARMEL, IN 46032 Z O N E D S H E E T I N D E XS H E E T I N D E X 1391 CORPORATE DRIVE, SUITE 203 | McHENRY, IL 60050 Phone: 815.385.1778 | Toll Free: 800.728.7805 | Fax: 713.965.0044 | HRGreen.com ALL "C" SHEETS AND ALL "PS" SHEETS 03/24/23 03/24/23 LANDS CAPE A R C H ITECTDAVIDL .REITZ R E G IS TERE DINDIA N A I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Landscape Architect under the laws of the State of Indiana. DATE DAVID LEE REITZ, L.A. License Number: LA20800121 My license renewal date is December 31, 2023. Pages or sheets covered by this seal: No. LA20800121 STATE OF I hereby certify that this engineering document was prepared by me or under my direct personal supervision and that I am a duly licensed Professional Engineer under the laws of the State of Indiana. DATEJOSEPH F. VAVRINA, P.E. License Number: PE11800597 My license renewal date is July 31, 2024. Pages or sheets covered by this seal: L-100 THRU L-103PROFESSION AL E N GINE ERJO SEPHF.VAVRINA ,IIIR EG ISTERE DINDIA N A No. PE11800597 STATE OF R Dial 811 or 1-800-892-0123 Know what'sbelow. Call before you dig. PROJECT LOCATION N. MICHIGAN ROADW . 99 T H S T R E E T ZONED: I-1 ZONED: B-3 FOR CONSTRUCTION WALNUT CREEK DRIVEZONED: B-3 ZONED: B-3 04/20/23 FOR CONSTRUCTION Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSION AL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-001 GENERAL NOTES, SPECIFICATIONS & LEGEND 04/20/23 FOR REFERENCE ONLY C-002 EXISTING CONDITIONS PLAN - 1 04/20/23 FOR REFERENCE ONLY C-003 EXISTING CONDITIONS PLAN - 2 04/20/23 REMOVALS / RELOCATES / ADJUSTMENTS NUMBER REMARKS A-1 STORM STRUCTURE ADJUST RIM TO FG R-1 BUILDING W/ FOUNDATION REMOVE R-2 TRASH ENCLOSURE W/ FOUNDATION REMOVE R-3 CONCRETE PAVEMENT REMOVE R-4 GAS METER REMOVE R-5 GAS LINE REMOVE SERVICE R-6 LIGHT POLE & BASE REMOVE R-7 TRAFFIC SIGN REMOVE R-8 TREE REMOVE R-9 SANITARY SEWER SERVICE REMOVE R-10 ASSUMED GREASE TRAP REMOVE R-11 BITUMINOUS PAVEMENT REMOVE (FULL DEPTH) R-12 STORM SEWER REMOVE R-13 STORM SEWER STRUCTURE REMOVE R-14 CONCRETE SIDEWALK REMOVE R-15 4" WATER SERVICE TO BLDG.REMOVE (TO POINT OF CONNECTION OR VALVE) R-16 LARGE SHRUBS REMOVE R-17 CONCRETE PARKING BUMPER REMOVE R-18 TELEPHONE SERVICE REMOVE R-19 ELECTRIC METER AND SERVICE REMOVE R-20 FENCE/GATE REMOVE R-21 CABLE TV SERVICE (ASSUMED)REMOVE R-22 UNDERGROUND ELECTRIC REMOVE R-23 CONCRETE CURB REMOVE R-24 CONCRETE WALL REMOVE R-25 SANITARY STRUCTURE REMOVE R-26 CONCRETE BOLLARD REMOVE R-27 MAILBOX REMOVE R-28 2" WATER SERVICE TO BLDG.REMOVE (LOCATION UNKNOWN) R-29 PAD MOUNTED TRANSFORMER REMOVE Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-100FOR CONSTRUCTION SITE DEMOLITION PLAN · · · · · · · · · · · · · · · · · · 04/20/23 DRI VE THRU DRI VETHRUDRIVE THRU DRI VETHRUInformation contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-200FOR CONSTRUCTION SITE PLAN 04/20/23 DRI VE THRUDRI VETHRUDRI VE THRUDRI VETHRUInformation contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-201FOR CONSTRUCTION OVERALL SITE PLAN 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-300FOR CONSTRUCTION GRADING PLAN R Dial 811 or 1-800-892-0123 Know what'sbelow. Call before you dig. 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-301FOR CONSTRUCTION GRADING DETAILS 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-302FOR CONSTRUCTION EROSION CONTROL PLAN · · · · · R Dial 811 or 1-800-892-0123 Know what'sbelow. Call before you dig. 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 PRELIMINARY 07/21/2022WEST CARMEL (IN) FSUPRELIMINARY04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 46032C-302P R E L I M I N A R Y NOT FOR CONSTRUCTION SWPPP PLAN · · · · · 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-303FOR CONSTRUCTION STORM WATER POLLUTION PREVENTION PLAN 04/20/23 0+00 1 +00 2+00 3+00 870 875 880 885 890 895 900 -1+00 870 875 880 885 890 895 900 4+00 870 875 880 885 890 895 900 -1+00 0+00 1 +00 870 875 880 885 890 895 900 2+00 870 875 880 885 890 895 900 -1+00 0+00 1+00 870 875 880 885 890 895 900 2+00 870 875 880 885 890 895 900 -1+00 0+00 1+00 2+00 870 875 880 885 890 895 900 4+00 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION C-304FOR CONSTRUCTION STORM SEWER PROFILES 04/20/23 1'-8"3'-0"1'-4" 3'-0" 8"4" 1'-8" 4" 4"8"4" PAINTED LINE (TYP.) 8" DIAM.1'-4"10" 1'-10" 8"1'-2" 14"R 4" 3'RPAINT SOLID PAINT SOLID 1'-2"1'-8"1'-8" 1'-2" 3'-0" 1'-0" 1'-2" 1'-0" 1'-2"3'-0"3'-0" NOTES: 1. GENERAL CONTRACTOR SHALL REFER TO PARKING LOT STRIPING SPECIFICATIONS, SEE DETAIL 2. PAVEMENT MARKINGS SHALL BE APPLIED ACCORDING TO REQUIREMENTS AS OUTLINED IN SECTION 3B OF THE CURRENT MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES 3. CONTRACTOR SHALL USE WHITE REFLECTIVE PAINT ON ASPHALT & YELLOW REFLECTIVE PAINT ON CONCRETE, UNLESS UPON VERIFICATION BY THE GENERAL CONTRACTOR IT IS DETERMINED THAT LOCAL, STATE, OR ADA CODES DIFFER, IN WHICH CASE THESE CODES SHALL GOVERN. DRIVE-THRU NOT TO SCALE ACCESSIBILITY SYMBOL NOT TO SCALE STOP BAR NOT TO SCALE DIRECTIONAL ARROW NOT TO SCALE 6'-0" 6'-0"12" SEE PLAN EDGE OF PAVEMENT OR FACE OF CURB STOP BAR 4'-0"EDGE OF PAVEMENTOR FACE OF CURBSIDEWALK W/ CURB & GUTTER NOT TO SCALE BOLLARD MOUNTED SIGN NOT TO SCALE 5 C-400 ACCESIBLE PARKING SIGN NOT TO SCALE 6 C-400 DIRECTIONAL SIGNAGE NOT TO SCALE STOP SIGN NOT TO SCALE 60° ANGLED PARKING STRIPING NOT TO SCALE 4 C-400 90° PARKING STRIPING NOT TO SCALE 3 C-400 PAVEMENT MARKINGS - 2 NOT TO SCALE 2 C-400 PAVEMENT MARKINGS - 1 NOT TO SCALE 1 C-400 NOTES: 1. GENERAL CONTRACTOR SHALL REFER TO PARKING LOT STRIPING SPECIFICATIONS, SEE DETAIL 2. PAVEMENT MARKINGS SHALL BE APPLIED ACCORDING TO REQUIREMENTS AS OUTLINED IN SECTION 3B OF THE CURRENT MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES 3. CONTRACTOR SHALL USE WHITE REFLECTIVE PAINT ON ASPHALT & YELLOW REFLECTIVE PAINT ON CONCRETE, UNLESS UPON VERIFICATION BY THE GENERAL CONTRACTOR IT IS DETERMINED THAT LOCAL, STATE, OR ADA CODES DIFFER, IN WHICH CASE THESE CODES SHALL GOVERN. 4. IF STOP SIGNS ARE PROPOSED, "STOP" LETTERING ON STOP BAR DETAIL IS NOT REQUIRED.18'-0"TYP.4" TRAFFIC STRIPING VAN 4" TRAFFIC YELLOW STRIPING @ 45° 2'-0" O.C. ACCESSIBLE SIGN SEE SITE SIGN BASE DETAIL TRAFFIC YELLOW ACCESSIBLE SYMBOL AND LETTERING EDGE OF SIDEWALK FACE OF CURB 8'-0" 8'-0" 8'-0" 9'-0" TYP. STOP VAN ACCESSIBLE RESERVED PARKING NOTES: 1. SIGNS SHALL BE FABRICATED USING S/F 0.08 NON-ILLUMINATED ALUMINUM WITH VINYL COPY APPLIED TO THE FIRST SURFACE. 2. VERIFY COLORS WITH JURISDICTIONAL AUTHORITIES. RED 'REFLECTIVE' COLOR WHITE 'REFLECTIVE' COLOR3"x3" SQUARE ALUMINUM TUBING, DARK BRONZE COLOR OR AS REQUIRED BY LOCAL JURISDICTION OR LANDLORD REQUIREMENTS. 30"30"7'-0" 2'-0" (MIN.)1"8"Ø CONCRETE BASE GREEN 'REFLECTIVE' COLOR BLUE 'REFLECTIVE' COLOR WHITE 'REFLECTIVE' COLOR BLUE 'REFLECTIVE' COLOR WITH WHITE 'REFLECTIVE TEXT' 2"x2" SQ. TUBING 1"R 12"18"6"LETTERING STYLE TO BE HELVETICA MEDIUM ACCESSIBLE PARKING SIGN (MUTCD R 7-8 AND R 7-8P5) (CIVIL TO VERIFY SIGN PANELS AND COLORS WITH STATE/LOCAL REQUIREMENTS) STOP SIGN & STANDARD MOUNTING POST (MUTCD R 1-1) PENALTY SIGN WITH WORDING AS REQUIRED BY STATE OR LOCAL LAW 5' MIN. WHITE 'REFLECTIVE' COLOR BUILDING FACE NOTES 1. ACCESSIBLE PARKING AND ACCESSIBLE AISLES SHALL NOT EXCEED 2% IN SLOPE IN ANY DIRECTION. IF ONLY ONE ACCESS ISLE IS INSTALLED, IT IS TO BE A VAN SIZE. 2. PARKING STALL DIMENSIONING SHALL BE IN ACCORDANCE WITH APPLICABLE GOVERNING AUTHORITIES & ADA STANDARDS. SEE SITE PLAN FOR COMPLETE STRIPING LAYOUT. 3. GENERAL CONTRACTOR SHALL REFER TO PARKING LOT STRIPING SPECIFICATIONS. 4. CONTRACTOR SHALL USE 4" WIDE WHITE REFLECTIVE PAINT FOR STRIPING ON ASPHALT PARKING LOTS. 5. CONTRACTOR SHALL USE 4" WIDE YELLOW REFLECTIVE PAINT FOR STRIPING ON CONCRETE PARKING LOTS. 6. NO WHEEL STOPS TO BE INSTALLED WHEN PARKING IS ADJACENT TO SIDEWALK. 7. ADA SIGNS IN BOLLARDS AND BOLLARDS SHALL BE INSTALLED WHEN PARKING IS ADJACENT TO FLUSH CURB OR A RAMP. 8. ALL DIMENSIONS ARE TO CENTERLINE OF STRIPE UNLESS NOTED OTHERWISE. 9. STRIPING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR V A N 8'-0"5 '-0" 9 '-0"9'-0" T YP.9 '-0" 60° 30°20'-0"TYP.R2'-0" MIN. 4" TRAFFIC BLUE STRIPING @ 45° 2'-0" O.C. TRAFFIC BLUE ACCESSIBLE SYMBOL AND LETTERING ACCESSIBLE SIGN SEE SITE SIGN BASE DETAIL BUILDING FACE 4" TRAFFIC STRIPING EDGE OF SIDEWALK FACE OF CURB NOTES 1. ACCESSIBLE PARKING AND ACCESSIBLE AISLES SHALL NOT EXCEED 2% IN SLOPE IN ANY DIRECTION. IF ONLY ONE ACCESS ISLE IS INSTALLED, IT IS TO BE A VAN SIZE. 2. PARKING STALL DIMENSIONING SHALL BE IN ACCORDANCE WITH APPLICABLE GOVERNING AUTHORITIES & ADA STANDARDS. SEE SITE PLAN FOR COMPLETE STRIPING LAYOUT. 3. GENERAL CONTRACTOR SHALL REFER TO PARKING LOT STRIPING SPECIFICATIONS. 4. CONTRACTOR SHALL USE 4" WIDE WHITE REFLECTIVE PAINT FOR STRIPING ON ASPHALT PARKING LOTS. 5. CONTRACTOR SHALL USE 4" WIDE YELLOW REFLECTIVE PAINT FOR STRIPING ON CONCRETE PARKING LOTS. 6. NO WHEEL STOPS TO BE INSTALLED WHEN PARKING IS ADJACENT TO SIDEWALK. 7. ADA SIGNS IN BOLLARDS AND BOLLARDS SHALL BE INSTALLED WHEN PARKING IS ADJACENT TO FLUSH CURB OR A RAMP. 8. ALL DIMENSIONS ARE TO CENTERLINE OF STRIPE UNLESS NOTED OTHERWISE. 9. STRIPING IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR C RIGHT TURN ONLY SIGN (REFER TO SIGN PACKAGE) A CIRCLE BUILDING FOR DRIVE-THRU SIGN (REFER TO SIGN PACKAGE) E ONE WAY SIGN (REFER TO SIGN PACKAGE)24"18"24" 18" WHITE 'REFLECTIVE' LETTERS FACE: 3M REFLECTIVE COPY (#3272 RED)COLOR D PEDESTRIAN CROSSWALK (REFER TO SIGN PACKAGE) B LEFT TURN ONLY SIGN (REFER TO SIGN PACKAGE)24"18"18.5" 12" BLACK 'REFLECTIVE' COLOR WHITE 'REFLECTIVE' COLOR 6" DIA. SCH. 80 STEEL PIPE BOLLARD PAINTED OSHA YELLOW FILLED WITH CONCRETE 4000 PSI CONCRETE 2'-6" 6"2'-0"7'-0" TO BOTTOM OF LOWEST REQUIRED SIGN2"X2" SQUARE TUBING PAINT CONCRETE BLACK AFTER CURING AT ASPHALT LOCATIONS 3'-0"30"30" ENTER DO NOT F DO NOT ENTER (REFER TO SIGN PACKAGE) 12"18.5"pedestrian crosswalk Circle ONE WAY Right Turn Only Left Turn Only WHITE 'REFLECTIVE' LETTERS FACE: 3M REFLECTIVE COPY (#3272 RED)COLOR Building For Drive -Thru Service NOTE: SIGNS SHALL BE FABRICATED USING S/F 0.08 NON-ILLUMINATED ALUMINUM WITH VINYL COPY APPLIED TO THE FIRST SURFACE. NOTE: VERIFY COLORS WITH LOCAL MUNICIPALITY. 7 C-400 8 C-400 10 C-400 BUILDING BUILDING FOOTING SIDEWALK ELEVATIONS VARY - HOLD FLUSH WITH FINISHED FLOOR AT ENTRANCE WAYS. PLANTING AREAS MAY EXIST BETWEEN THE BUILDING AND THE BACK-OF-SIDEWALK (SEE SITE PLAN). EXPANSION JOINTS DO NOT APPLY TO SIDEWALK SECTION ADJACENT TO PLANTING AREAS. NOTICE: ALWAYS ALIGN CURB AND SIDEWALK JOINTS. COMPACTED SUBGRADE AS SPECIFIED 6.5' MIN. (SEE SITE PLAN) CONCRETE CURB & GUTTER PAVEMENT, AS SPECIFIED IN GEOTECHNICAL REPORT STABILIZED AGGREGATE BASE COARSE, AS SPECIFIED FOR PAVEMENT SLOPE 1.5% MAX. 4" AGGREGATE BASE COURSE EXPANSION JOINT EXPANSION JOINT 11 C-400 24 C-401 24 C-401 12"6" 1A C-400 1B C-400 2A C-400 2B C-400 CONCRETE CURB & GUTTER NOT TO SCALE 11 C-400 CATCHING CURB AND GUTTER 112"R 1"6" 2'-0" PAVEMENT DIMENSION REFER TO FACE OF CURB UNLESS INDICATED OTHERWISE 12"R 6"13"6"SPILLING CURB AND GUTTER 112 "R 1"6" 2'-0" PAVEMENT DIMENSION REFER TO FACE OF CURB UNLESS INDICATED OTHERWISE 12"R 6"12"7"1-1/8"B A LIGHT BROOM FINISH 1-1/8"112"R 7" PAVEMENT DIMENSION REFER TO FACE OF CURB UNLESS INDICATED OTHERWISE 12"R C 6" 112"R 7" 2'-0" PAVEMENT DIMENSION REFER TO FACE OF CURB UNLESS INDICATED OTHERWISE 12"R 7 1/2" D LIGHT BROOM FINISH 6"3/4" 2'-0"6"LIGHT BROOM FINISH 5.0% MAX.3/4" 5.0% MAX. 34" PER FT. 34" PER FT. LIGHT BROOM FINISH 1:20 MAX.SLOPE 1:14 MAX. SLOPE ROADWAY GUTTER PAN DEPRESSED CURB CURB RAMP E 1:20 MAX. SLOPE 1:14 MAX. SLOPE ROADWAY GUTTER PAN CURB RAMP F DEPRESSED SPILLING CURB AND GUTTER DEPRESSED CATCHING CURB AND GUTTER CATCHING GUTTER SECTION AT ACCESSIBLE RAMP SPILLING GUTTER SECTION AT ACCESSIBLE RAMP NOTES: 1. CONC. FOR CURBING SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 3,500 PSI @ 28 DAYS 2. CONTRACTION JOINTS @ 1-'0" O.C. TOOLED 14" (± 116", -0) WIDE, 1" OR MAX. D/4 DEPTH WHICHEVER IS GREATER. EXPANSION JOINTS @ 40'-0" MAX. UNLESS NOTED OTHERWISE ON PLANS 3. IF NEEDED, DOWEL INTO ADJACENT CONC. SLAB PER THE EXPANSION JOINT DETAIL. 4. GUTTER SLOPE TO MATCH ADJACENT PAVEMENT, TRAVERSE & LONGITUDINAL. CONCRETE PAVEMENTS NOT TO SCALE 12 C-400 MEDIUM DUTY #4 BARS - 18" O.C.E.W. 4" PCC SURFACE COURSE BASE COURSE PER GEOTECH REPORT NOTES: 1. DESIGN PER GEOTECH REPORT BY , DATED . 2. PAVEMENTS & SUBGRADES INCLUDING MATERIALS & COMPACTION SHALL MEET STANDARDS & SPECIFICATIONS OF THE GOVERNING DEPARTMENT OF TRANSPORTATION. 3. JOINTING & SPACING SHALL BE PER CONCRETE JOINT DETAILS. 4. CONCRETE SHALL HAVE A MIN. COMPRESSIVE STRENGTH OF 3,500 PSI @ 28 DAYS. STABLE SUBGRADE OR COMPACTED SELECT FILL AS REQUIRED PER GEOTECH REPORT HEAVY DUTY #4 BARS - 18" O.C.E.W. 6" PCC SURFACE COURSE BASE COURSE PER GEOTECH REPORT STABLE SUBGRADE OR COMPACTED SELECT FILL AS REQUIRED PER GEOTECH REPORT X X X X X X XX X X X X 12" EXPANSION JOINT (SEE NOTE #1) SMOOTH TOOLED FINISH AROUND ALL EDGES AND JOINTS (TYP) LIGHT BROOM FINISH (PERPENDICULAR TO TRAVEL PATH) 6"x6"x6 GAUGE WELDED WIRE FABRIC SEATED AND SECURED ON STANDS 5'-0" (TYP)2"2"4" 12" CONTRACTION JOINT (SEE NOTE #1) CONTRACTION JOINT 3000 PSI COMPRESSIVE STRENGTH CONCRETE MIX PER SPECIFICATION.2"4"EXPANSION JOINT 12" CONTRACTION JOINT (SEE NOTE #1)SEE PLAN4" AGGREGATE BASE COURSE 12" DECK-O-FOAM EXPANSION JOINT FILLER W/ PRE-SCORED STRIP, "ZIP STRIP" OR OTHER CFA APPROVED MATERIAL URETHANE JOINT SEALING COMPOUND 14 TNOTES: 1. JOINTS AT 5'-0" O.C. TOOLED 1 2" WIDE, 1" DEEP OR MAX. D 4 DEEP WHICHEVER IS GREATER. EXPANSION JOINTS AT 20' MAX. & ALL P.C.s, UNLESS APPROVED OR INDICATED OTHERWISE ON PLAN VIEW JOINT PATTERN. CONCRETE SIDEWALK NOT TO SCALE 9 C-400 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSION AL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION CHICK-FIL-A STANDARD CONSTRUCTION DETAILS C-400 04/20/23 17 C-401 SIDEWALK ACCESSIBLE RAMP NOT TO SCALE 16 C-401 CURB RAMP w/ FLARED SIDES NOT TO SCALE 14 C-401 CURB RAMP w/ SHORT FLARED SIDES NOT TO SCALE 13 C-401 19 C-401 18 C-401 21 C-401 MATCH SIDEWALK WIDTH (3' MIN. RAMP) PAVEMENT 7' MIN. 1' MIN. TRANSITION 6"6"1V:14H MAX. 1' MIN. TRANSITION CURB CURB 24"FLARED SIDES GRASSGRASS 17 C-4013'x3'LANDINGGUTTER SLOPE SHALL NOT EXCEED 5% AT LANDING AREA MATCH SIDEWALK WIDTH (3' MIN. RAMP) PAVEMENT 7' MIN. 1V:10H MAX. 5' MIN. TRANSITION 6"6"1V:14H MAX. 1V:10H MAX. 5' MIN. TRANSITION CURB SIDEWALK CURB SIDEWALK 24"DETECTABLE WARNING DEVICE (WHERE REQUIRED) FLARED SIDES 1V:10H MAX.17 C-4013'x3'LANDING* SIDE FLARES TO BE 1:12 WHERE THERE IS NO LANDING AT TOP OF RAMP. GUTTER SLOPE SHALL NOT EXCEED 5% AT LANDING AREA 1/2" EXPANSION JOINTS (TYP.) DETECTABLE WARNING DEVICE (WHERE REQUIRED) BOTTOM OF THE RAMP SHALL HAVE A MAX. 1/4" LIP ELEVATION NOTE: PREFABRICATED PANELS PER A.D.A. ACCESSIBILITY GUIDELINES SECTION 4.29.2 & A4.29.2 SHALL BE USED. NOTES: 1. THE SURFACE OF THE RAMP SHALL HAVE DETECTABLE WARNINGS AS SHOWN. DETECTABLE WARNINGS SHALL CONSIST OF RAISED TRUNCATED DOMES. SEE DETECTABLE WARNINGS DETAIL. 2. CONSTRUCT PER A.D.A. STANDARDS. 3. REFER TO PLANS FOR ADJACENT SLOPES. 4. THE CROSS SLOPE OF THE RAMP SURFACE SHALL BE NO GREATER THAN 1:50. 5. CONSTRUCTION OF THE RAMP SHALL MATCH ADJOINING SIDEWALK DETAIL. 6. CONCRETE SHALL BE P.C.C. 3500 PSI. 5'-0" PLAN MAX.MAX. 1:141:14 1.5% MAX.SURFACES OF RAMP SHALL HAVE A TRANSVERSE BROOMED SURFACE TEXTURE (TYP.)VARIESSEE SITE PLANPLAN SECTION A 5'-0" MIN. LANDING 7'-0" TRANSITION FROM 0" TO 6" AA TRANSVERSE AND LONGITUDINAL CONTRACTION JOINT NOT TO SCALE TRANSVERSE AND LONGITUDINAL DOWELED CONSTRUCTION JOINT NOT TO SCALE CONTRACTION JOINT NOT TO SCALE PROPOSED PAVING EXISTING PAVING 34" GRADE A36 STEEL DOWEL 14" LENGTH, 12" O.C. SPACING, GREASE OR SLEEVE ONE END SUBBASE SEE NOTE #1 DOWELED CONSTRUCTION JOINTSEE PLAN FOR SLAB THICKNESS 4000 PSI COMPRESSIVE STRENGTH CONCRETE DNOTE: 1. GENERAL CONTRACTOR SHALL REFERENCE GEOTECHNICAL REPORT FOR PAVEMENT SECTION REQUIREMENTS. VERTICAL SAW CUT 3 8" WIDE (MIN.) URETHANE JOINT SEALING COMPOUND (TOP 14" NO SEALING COMPOUND) 5" TYPICAL (SEE GEOTECHREPORT FORRECOMMENDATIONS12 DEPTHT4#3 BARS ON 18" CTRS. BOTH WAYS SUBBASE SEE NOTE #1 NOTES: 1. JOINT SPACING TO BE 12' x 12' WITH EVERY OTHER JOINT BEING AN EXPANSION JOINT. 2. GENERAL CONTRACTOR SHALL REFERENCE GEOTECHNICAL REPORT FOR PAVEMENT SECTION REQUIREMENTS. SUBBASE SEE NOTE #1 SEE PLAN FOR SLAB THICKNESS 4000 PSI COMPRESSIVE STRENGTH CONCRETE 14" WIDE SAWED OR PREMOLDED JOINT, 12' MAX. SPACING, SEAL JOINTS WITH POLYURETHANE SEALANT TO WITHIN 14 " FROM TOP.D D4NOTE: 1. GENERAL CONTRACTOR SHALL REFERENCE GEOTECHNICAL REPORT FOR PAVEMENT SECTION REQUIREMENTS. NOTES: 1. THE DETECTABLE WARNING DEVICE SHALL BE LOCATED SO THAT THE NEAREST EDGE OF THE DEVICE IS 6 TO 8 INCHES FROM THE FACE OF CURB LINE. 2. DETECTABLE WARNING DEVICE SHALL BE 24 INCHES IN THE DIRECTION OF TRAVEL AND EXTEND THE FULL WIDTH OF THE RAMP OR FLUSH SRUFACE. 3. DETECTABLE WARNING SURFACES SHALL BE CONSTRUCTED BY TEXTURING PRODUCTS CONFORMING TO PROWAG R304. TRANSITION SLOPES ARE NOT TO HAVE DETECTABLE WARNINGS. CONTRACTOR SHALL CONFIRM LOCAL CODES ARE MET. 4. WHERE A CURB RAMP IS CONSTRUCTED WITHIN AN EXISTING CURB, CURB & GUTTER AND/OR SIDEWALK, THE EXISTING CURB & GUTTER SHALL BE REMOVED TO THE NEAREST JOINT BEYOND THE CURB TRANSITIONS OR TO THE EXTENT THAT NO REMAINING SECTION OF CURB OR CURB & GUTTER IS LESS THAN 5' LONG. THE EXISTING SIDEWALK SHALL BE REMOVED TO THE NEAREST JOINT BEYOND THE TRANSITION SLOPE WALK AROUND OR TO THE EXTENT THAT NO REMAINING SECTION OF SIDEWALK IS LESS THAN 5'. 5. THE PLAN MUST PROVIDE FOR DETECTABLE WARNING SURFACE COLORS OR MATERIALS THAT PROVIDE THE NECESSARY CONTRAST, EITHER DARK-ON-LIGHT, OR LIGHT-ON-DARK. STANDARD DOME COLOR IS BRICK RED. 6. TRUNCATED DOMES TO BE INSTALLED USING ARMOR TILE CAST IN PLACE DOME TACTILE TILE. PART NUMBER ADA-2424 OR OTHER EQUIVALENT APPROVED MATERIAL. PREFERRED MANUFACTURER ARMOR TILE TACTILE SYSTEMS LANCE MITCHELL(919)622-4615 UNLESS PAVERS ARE REQUIRED, CONTRACTOR TO VERIFY THAT CURB RAMPS MEET LOCAL CODES AND ADA REQUIREMENTS.0.2"0.9"Ø0.90"Ø0.45"0.0625 0.09" TYP. 0.09" TYP.2.350" T Y P .NOTE: FIELD LEVEL MICRO-TEXTURE 41 POINTS PER SQUARE INCH 1.2625" 1.2625"1.670" TYP. 1.670" TYP. DETECTABLE WARNING DEVICE NOT TO SCALE DETECTABLE WARNING DEVICE (WHERE REQUIRED) 17 C-401 LONGITUDINAL BUTT JOINT NOT TO SCALE 23 C-401 VERTICAL SAW CUT 38" (MIN.) URETHANE JOINT SEALING COMPOUND DOWEL SPACED ON TWO (2) FOOT CENTER TO CENTER, 6 INCHES OFF TIE BARS. EXISTING PAVINGPAVING PROPOSED 24" LUBRICATED SMOOTH NO. 8 DOWEL BAR 1'-3" MIN.14TTOP 14" NO SEALING COMPOUND SAWCUT FULL DEPTH & CURB & GUTTER 9"-15"5" TYPICAL (SEE GEOTECH REPORTFOR RECOMMENDATIONS)12 DEPTHNOTES: 1. NO. 5 SMOOTH DOWEL BAR MAY BE USED IN 5 INCH AND 6 INCH PAVEMENT THICKNESS. 2. LONGITUDINAL BUTT CONSTRUCTION MAY BE UTILIZED IN PLACE OF LONGITUDINAL HINGED (KEYWAY) JOINT AT CONTRACTORS OPTION. 3. DOWEL BARS SHALL BE DRILLED & EPOXIED INTO PAVEMENT HORIZONTALLY BY USE OF MECHANICAL EQUIP. 4. PUSHING DOWEL BARS INTO WET CONCRETE NOT ACCEPTABLE. #3 BARS ON 16" ON CENTER EACH WAY LUBRICATE EPOXY X X X LANDSCAPE AREA LANDSCAPE AREA W IDTH V A RI ES (4' MIN. WI DTH) 6" STANDUP CURB OR CURB & GUTTER AS APPLICABLE (SEE SITE PLAN)PROVIDE 5' SQUARE MINIMUM LANDING AT TOP OF RAMP FOR CHANGE IN DIRECTION EXPANSION JOINT S EE SI TE P L A N 1:14 M A X . S L O P E DO N O T E X C E E D TRUNCATED DOMES BOTH RAMP CURBS TO BE PAINTED YELLOW, SEE PARKING LOT STRIPING SPECIFICATION EXPANSION JOINT EXPANSION JOINT CONTRACTIONJOINT CONTRAC T I O N JOINT RETURNED CURB ACCESSIBLE RAMP NOT TO SCALE 15 C-401 4 C-400 17 C-401 24 C-401 24 C-401 24 C-4019 C-400 CONCRETE SIDEWALK (ONLY IF REQUIRED) 24 C-401 EXPANSION JOINT NOT TO SCALE 11 4" MIN. CLEARANCE DOWEL SLEEVE (CLOSED END) TO FIT DOWEL AND BE SECURED. TO BE INSTALLED 1'-0" C.C. 24" LUBRICATED NO. 8 SMOOTH DOWEL 2" (MIN.) 5" TYPICAL (SEE GEOTECH REPORTFOR RECOMMENDATIONS 12 DEPTHNOTES: 1. NO. 5 SMOOTH DOWEL BAR MAY BE USED IN 5 INCH AND 6 INCH PAVEMENT THICKNESS. 2. LONGITUDINAL BUTT CONSTRUCTION MAY BE UTILIZED IN PLACE OF LONGITUDINAL HINGED (KEYWAY) JOINT AT CONTRACTORS OPTION. 3. DOWEL BARS SHALL BE DRILLED INTO PAVEMENT HORIZONTALLY BY USE OF A MECHANICAL EQUIPMENT. 4. DRILLING BY HAND IS NOT ACCEPTABLE, PUSHING DOWEL BARS INTO WET CONCRETE NOT ACCEPTABLE. 5. JOINT SPACING TO BE 24'X24' (EVERY OTHER JOINT) #3 BARS ON 16" ON CENTER EACH WAY LUBRICATE THIS END XX X 12" DECK-O-FOAM EXPANSION JOINT FILLER W/ PRE-SCORED STRIP OR OTHER CFA APPROVED MATERIAL URETHANE JOINT SEALING COMPOUND 14T22 C-401 KEYED CONSTRUCTION JOINT NOT TO SCALE PROPOSED CONCRETE PAVING EXISTING ASPHALT PAVEMENT AND BASE COURSE CONTRACTOR TO SAW CUT, REMOVE AND REPLACE 2' OF EX. ASPHALT PAVEMENT TO CONSTRUCT KEY JOINT. 2' REMOVAL ZONE5" TYPICAL (SEE GEOTECHREPORT FORRECOMMENDATIONS SAWCUT LINE 4:1 SLOPE 0.1 20 C-401 PAVEMENT EDGE DETAIL NOT TO SCALE ASPHALT PAVEMENT AND BASE COURSEPAVEMENT THICKNESSSEE NOTE #112" 10" MINREQUIRED AT ALL JUNCTIONS WITH CONCRETE NOTE: 1. GENERAL CONTRACTOR SHALL REFERENCE GEOTECHNICAL REPORT FOR PAVEMENT SECTION REQUIREMENTS. THESE DETAILS APPLY TO CONCRETE PAVED LOTS Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSION AL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION CHICK-FIL-A STANDARD CONSTRUCTION DETAILS C-401 04/20/23 BUILDING DOWNSPOUT CONNECTION NOT TO SCALE 30 C-402 CROSSWALK MARKINGS NOT TO SCALE ALUMINUM HANDRAIL NOT TO SCALE BUTT JOINT NOT TO SCALE 28 C-402 TYPICAL HMA PAVEMENT SECTION NOT TO SCALE 27 C-402 CONCRETE PAVEMENT DRIVE-THRU LANE NOT TO SCALE 26 C-402 31 C-402 32 C-402 34 C-402 33 C-402 1'-0" 60" MIN LANDING HORIZONTAL PROJECTION (RUN) 60" MIN. LANDING 1'-0"34"-38"HANDRAIL 36" CLEAR (MIN) "A" "B" ELEVATION 30" MAX. RISE BEFORE A 5'-0" LONG INTERMEDIATE LANDING IS REQUIRED SET PIPE IN CONC. FOOTING DETAIL "A" DETAIL "B" 114"Ø TO 112"Ø HANDRAIL34"-38"A.F.F.8" SQUARE 3"MIN 1'-0"VERIFY HANDRAIL 12" SUBBASE SEE NOTE #1 6"x6"x6 GAUGE WELDED WIRE FABRIC SEATED AND SECURED ON STANDS 4000 PSI COMPRESSIVE STRENGTH CONCRETE MIX PER SPECIFICATION.6"2"XX X X EXTEND BASE 6" BEYOND FOR APPLICATIONS WITHOUT CURB & GUTTER, SIDEWALKS, BUILDINGS OR OTHER STRUCTURES. 2.5" THICK ASPHALTIC BINDER COURSE (INDOT 402 INTERMEDIATE, TYPE B) (19.0mm) 1.5" THICK ASPHALTIC SURFACE COURSE (INDOT 402 HMA SURFACE, TYPE B) (9.5mm) 8" THICK AGGREGATE BASE COURSE (INDOT NO. 53 STONE) IF PRESENT ON-SITE, UNSUITABLE SUBGRADE MATERIAL SHALL BE REPLACED WITH SUITABLE MATERIAL AS SPECIFIED IN THE GEOTECHNICAL REPORT.RISE 4" AGGREGATE BASE COURSE SEE NOTE #1. PAINT HANDRAIL DARK BRONZE NOTE: 1. GENERAL CONTRACTOR SHALL REFERENCE SITE SPECIFIC GEOTECHNICAL REPORT FOR PAVEMENT, AGGREGATE, AND SUBGRADE SECTION REQUIREMENTS. 2. MINIMUM PAVEMENT THICKNESS SHOULD BE 8" GRADED AGGREGATE BASE, 2.5"ASPHALT PAVEMENT BINDER & 1.5" ASPHALT PAVEMENT SURFACE COURSE TACK COAT. NOTE: 1. GENERAL CONTRACTOR SHALL REFERENCE GEOTECHNICAL REPORT FOR PAVEMENT SECTION REQUIREMENTS.34"-38"NOTES: 1. RAMPS & HANDRAILS TO BE IN COMPLIANCE WITH SECTIONS 405 & 505 OF THE 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN 2. VERIFY ALL STATE & LOCAL REQUIREMENTS FOR RAMPS & HANDRAILS 3. USE ONLY COMMERCIAL GRADE ALUMINUM FENCING WITH DARK BRONZE POWDER COAT FINISH SUBBASE SEE NOTE #1 42"0" 43" 618" 1" 6858" 34" x 34" x .050 PICKET GRADE TOP RAILS 114" x 114" CHANNEL .062" TOP WALL .078" SIDEWALL41116" SPACING NOTE: 1. USE ONLY COMMERCIAL GRADE ALUMINUM FENCING WITH DARK BRONZE POWDER COAT FINISH 2. ALL POSTS TO HAVE 14"Ø WEEP HOLES @ 12" ABOVE FG; WEEP HOLES TO BE DRILLED AFTER POSTS & RAILS ARE INSTALLED CONCRETE SIDEWALK BOTTOM RAILS 11 4" x 114" CHANNEL .062" TOP WALL .078" SIDEWALL PAINT SOLID MULTI-LANE SPLIT MULTI-LANE MERGE5' 1.5'2.5'5' 1.5'2.5'PAINT SOLID NOTES: 1. GENERAL CONTRACTOR SHALL REFER TO PARKING LOT STRIPING SPECIFICATIONS, SEE DETAIL 2. CONTRACTOR SHALL USE WHITE REFLECTIVE PAINT ON ASPHALT & YELLOW REFLECTIVE PAINT ON CONCRETE. 5 C-4.0 TACK COAT (INDOT 406.05) (APPLY AT 0.05 TO 0.10 GALLONS PER S.Y.) TO WITHIN 5' FROM BUILDING, REMAINDER TO BUILDING & HOOKUP IS TENANT RESPONSIBILITY OPTION "B" - SMALLER BUILDINGS 1% MINIMUM SLOPE STORM SEWER PIPE (SIZE VARIES) SEE GRADING PLAN FOR LOCATIONSEE NOTE #2 SEE NOTE #1 45° BEND (SCH 40 PVC) 2" MAXIMUM 6" SCHEDULE 40 PVC WITH PVC CAP 5"x 6" DOWNSPOUT 1" MIN. DEEP POLYURETHANE SEALANT BED 8"8"16" 9" 6"3"SET PIPE IN CONCRETE FOOTING USING SUPER POR-ROK GROUT (TYP.); EMBED 3" MIN.27" MAX.27" MAX.SAWCUT EXISTING ASPHALT FULL DEPTH FOR CLEAN CONSTRUCTION JOINT PROPOSED ASPHALT PAVEMENT EXISTING ASPHALT PAVEMENT JOINT SEALANT (AC-20, OR EQUIVALENT)< 4"CONCRETE BOLLARD NOT TO SCALE 29 C-402 6"° STEEL PIPE (SCHEDULE 80) FILLED WITH CONCRETE PAINT BOLLARD WITH DARK BRONZE TONE EXTERIOR ENAMEL PAINT AT DRIVE THRU. PAINT BOLLARD WITH BRONZE COLOR AT ALL OTHER LOCATIONS. ANCHOR STEEL PIPE IN CONCRETE FOOTING, 2'-0" DIAMETER x 2'-6" DEPTH ASPHALT PAVEMENT APPLICATIONS CONCRETE PAVEMENT/ SLAB APPLICATIONS 2'-6"6"2'-0" TROWELED, ROUNDED CONCRETE 24 C-401 EXPANSION JOINT 3'-0" UNLESS NOTED OTHERWISE5'-0" AT DRIVE-THRU WINDOWMULTI-LANE DIRECTIONAL GRAPHICS NOT TO SCALE 12" WIDE WHITE STRIPES @ 36" CENTERS 2. 1. NOTES: MARKINGS WITHIN PRIVATE PARKING LOT SHALL BE PER THIS DETAIL. SEE SITE PLAN AND GUTTER TYPICAL CURB 3. THESE MARKINGS ARE TO BE PAINTED REFLECTIVE WHITE. SIGN TO BE PLACED AT THE LEADING/ TRANSVERSE LINES OF THE CROSSWALK PER THE SITE PLANVARIES (6' MIN.)(SEE SITE PLAN)MARKINGS FOR STREET SHALL BE ACCORDING TO LOCAL CODE REQUIREMENTS AND AS OUTLINED IN SECTION 3B OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS. SIGN TO BE PLACED AT THE LEADING/ TRANSVERSE LINES OF THE CROSSWALK PER THE SITE PLAN 2-1/2" SQ. POST TYPICAL ADA RAMP & HANDRAIL NOT TO SCALE NOTES: 1. FOR ALL DEPTHS OF COVER LESS THAN TWO (2) FEET, PIPE MUST BE SCHEDULE 40 PVC. FOR DEPTHS OF COVER GREATER THAN TWO (2) FEET, FLEXIBLE PIPE MAY BE USED. REFER TO SPECIFICATIONS FOR ALLOWABLE PIPE TYPES. 2. A WATERTIGHT CONNECTION SHALL BE MAINTAINED WITH ANY TRANSITION FROM SCHEDULE 40 PVC PIPE TO ANY OTHER PIPE TYPE. 3. THE DOWNSPOUT COLLECTOR DRAIN SHALL BE INSTALLED BEFORE THE DOWNSPOUTS ARE INSTALLED ON THE BUILDING. SITEWORK CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK INCLUDING THE RODENT SCREEN. BUILDING CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONNECTION AT THE POINT OF THE RODENT SCREEN. ROLLOVER / MOUNTABLE CURB NOT TO SCALE DRIVE-THRU CLEARANCE BAR NOT TO SCALE 35 C-402 36 C-402 NOTES: 1. GENERAL CONTRACTOR SHALL REFERENCE GEOTECHNICAL REPORT FOR PAVEMENT SECTION REQUIREMENTS. 2. EXPANSION JOINT FILLER SHALL BE FLEXIBLE, LIGHTWEIGHT, NON-STAINING, POLYETHYLENE, CLOSED-CELL EXPANSION JOINT 3-12 MOUNTABLE DOME CURB NOTES #4's @ 12"O.C. EACH WAY (N.T.S.)8" 3"12" 1. PRE-CUT EXPANSION JOINT MATERIAL SHALL BE USED IN ALL EXPANSION JOINTS. 2. DUMMY JOINTS SHALL BE INSTALLED AT 10 ft. INTERVALS, MAXIMUM. 3. INSTALL EXPANSION JOINTS EVERY 40 ft., MAXIMUM, AT ENDS OF RADIUS, AND A MINIMUM OF 5 ft. FROM INLET STRUCTURES. 4. BREAK AS NEEDED TO ENSURE POSITIVE DRAINAGE 5. CONCRETE TO BE 5,000 P.S.I. 6. MOUNTABLE CURB TO BE PAINTED YELLOW. 13" x 13" x 3 4" STEEL BASE PLATE W/ (4) 34"Ø ANCHORS ON 9" CENTERS IN EA. DIRECTION8'-9"9'-0"8" FROM BACK OF CURB2'-0"ETCHED PLATE ON REAR OF CENTER SUPPORT; SEE SIGN STANDARDS PIVOT 9'-0" CLEARANCE FLAT CUT ALUMINUM COPY ON FACE OF ARM FACING ENTRY TO DRIVE-THRU TO MATCH SW #5403 GRAY DRIVE-THRU LANE 9'-0" 3" x 3" x 316" HSS w/ CAPPED ENDS 6" x 6" x 316" HSS w/ 38" STEEL CAP PLATE 34"Ø x 36" HEADED ANCHOR BOLTS w/ 3 12" PROJECTION ABOVE GRADE; #4 TIES @ 12" O.C. 2'-0"Ø x 4-0" DEEP CONC. PIER FOUNDATION; VERIFY PIER SIZE w/ GEOTECHNICAL REPORT PRIOR TO CONSTRUCTION NOTES: 1. ENTIRE CLEARANCE BAR & HARDWARE TO BE POWDER COATED QPC P-820 MATTE BLACK FINISH 2. CLEARANCE BAR ARM TO ROTATE WHEN STRUCK & RETURN TO ORIGINAL POSITION 3. COORDINATE w/ THE ARCHITECT & STRUCTURAL ENGINEER 25 C-402 CONCRETE APRON AT TRASH ENCLOSURE NOT TO SCALE ASPHALT PAVEMENT AND BASE COURSE #4 REBAR FOR CONTINUOUS REINFORCEMENT OF THICKENED EDGE 6" SUBBASE SEE NOTE #1 #3 @ 12" ON CENTER EACH WAY 4000 PSI COMPRESSIVE STRENGTH CONCRETE 12" 7"MIN.6" AGGREGATE BASE COURSE SEE NOTE #1.10" MIN9"PAVEMENT THICKNESSSEE NOTE #1NOTE: 1. GENERAL CONTRACTOR SHALL REFERENCE GEOTECHNICAL REPORT FOR PAVEMENT SECTION REQUIREMENTS. 2"3"Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSION AL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION CHICK-FIL-A STANDARD CONSTRUCTION DETAILS C-402 04/20/23 40 C-403 DRIVE-THRU ORDER POINT ISLAND NOT TO SCALE SCREENED REFUSE ENCLOSURE (DRAINAGE ALT.) NOT TO SCALE 38B C-403 SCREENED REFUSE ENCLOSURE (ALT.) NOT TO SCALE 38A C-403 41 C-403 6" PIPE BOLLARD FILLED w. CONCRETE PAINTED DARK BRONZE 6" 6" PIPE BOLLARD PAINT 2" TOP OF CURB YELLOW PAINT FACE OF CURB YELLOW12"CANOPY ABOVE MENU BOARD ISLAND CURB ELEVATION3'-0" 8'-0" ISLAND PLAN 29 C-402 12 - 18"3'3' 3' 7.5'LOOP 1.5 x 5 FEET 9' - 9.5' MENU BOARD MICROPHONE SPEAKER D RIVE THRU L A N E C ONC R E T E P A VI NG 1 2 2 5 3 4 6 7 1 2 3 4 5 6 7 PREFAB (FOLDED) LOOP (1.5' x 5') 1/2" PVC COUPLING 1/2" PVC SLEEVE COUPLING 1/2" PVC TUBING (3' LENGTH) 1/2" PVC CORNER FITTING 1/2" PVC 90° ELBOW 1/2" PVC TUBING (2' LENGTH) PARTS LIST NOTES: 1. LOOP DETECTOR IS MODEL NO. VDL100 VEHICLE DETECTION LOOP MANUFACTURED BY MH ELECTRONICS, INC. 2. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. CONDUIT FROM BUILDING MENU BOARD FOUNDATION MENU BOARD LOOP SUPPORT VEHICLE LOOP DETECTOR DRIVE THRU LANE CONCRETE PAVING 2" CLEAR BETWEEN LOOP AND SURFACE PLAN VIEW SECTION VIEW ISOMETRIC VIEW 3' CLEAR PERIMETER, FREE FROM REBAR, WIRE SCREEN, REINFORCING BARS, ELECTRIC CABLE OR METAL OBJECTS. 1 4 2 5 C JC JC J C J EJ EJEJ EJ 6'12' CONC. SLAB POURED W/ ISLAND RESUME TYP. CJ PATTERN RESUME TYP. CJ PATTERN EXTEND CJ THROUGH CURB (TYP.) EQ TYP 4'-0" TYP EQ TYP EDGE OF SPREAD FOOTING BLOCK LEDGE SAW JOINT 0'-6" TOP OF SLAB 0'-0" TOP OF SLAB 12'-1012"8"512" 34'-0"1'-0"2'-0"2'-0" TYP.EQUALEQUAL 35'-0"EQUAL 10'-0" 10'-0" 13' 6'-8" 8" 8" 13' 8" 8" 512" 12'-1012" IF INTERIOR DRAIN IS NOT REQUIRED, OMIT 8" BLOCK WIDTH AT FLOOR LEVEL BOTH SIDES, FOR DRAINAGE OUTSIDE OF DUMPSTER AREA.6'-3"RAMP1:120'-6" TOP OF SLAB 6" THICK 4000 PSI CONCRETE APPROACH PAD WITH #3's @ 12" ON CENTER EACH WAY +6" TOP OF SLAB NOTES: 1. ARCHITECT SHALL VERIFY SIZE & COORDINATE WITH STRUCTURAL ENGINEER. 2. RE: CIVIL FOR DRAINAGE. 8" GATE POSTS FOUNDATION RE: CIVIL EDGE OF FOOTING BELOW PIPE BOLLARDS EMBED BOLLARDS IN 18" DIA. x 3'-6" CONCRETE FILLED HOLE 34'-0" 8" 12' 3 1/2" 12' 3 1/2" 8'-0" 3'-9" 4'-0"9'-2"4'-0" 4'-5" 8" 2'-0" TYP. 8" 8" 25'-4" 6'-8"8" 8"8" 8'-8" 8"10'-0"6"2'-0" TYP. 8"8"2'-0" TYP. 8" 8"10'-0" SAW CUTRE: CIVIL13'-4"9"TYP.9" 3"3" SAW JOINT 2'-0" TYP.2'-0"TYP.SAW JOINT EQUAL EQUAL6" THICK 4000 PSI CONCRETE APPROACH PAD WITH #3's @ 12" ON CENTER EACH WAY 35'-0"IF INTERIOR DRAIN IS NOT REQUIRED, OMIT 8" BLOCK WIDTH AT FLOOR LEVEL, BOTH SIDES, FOR DRAINAGE OUTSIDE OF DUMPSTER AREA. CONNECT FLOOR DRAIN TO STORM DRAIN SYSTEM, PER LOCAL REQUIREMENTS CJ = CONTRACTION JOINT EJ = EXPANSION JOINT MENU BOARD LOOP DETECTION SYSTEM NOT TO SCALE 39 C-403 MENU BOARD LOOP DETECTION SYSTEM (ISO. VIEW) NOT TO SCALE 1 2 3 4 5 6 7 PREFAB (FOLDED) LOOP (1.5' x 5') 1/2" PVC COUPLING 1/2" PVC SLEEVE COUPLING 1/2" PVC TUBING (3' LENGTH) 1/2" PVC CORNER FITTING 1/2" PVC 90° ELBOW 1/2" PVC TUBING (2' LENGTH) PARTS LIST NOTES: 1. LOOP DETECTOR IS MODEL NO. VDL100 VEHICLE DETECTION LOOP MANUFACTURED BY MH ELECTRONICS, INC. 2. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR INSTALLATION. CLEAN-OUT OUTSIDE OF BUILDING NOT TO SCALE 46 C-403 PIPING IS FREE OF C.O. COVER SUCH THAT LOADING IS NOT TRANSMITTED TO PIPING. COMBINATION, TYP. SANITARY 4" THICK CONCRETE PAD CLEAN OUT AND COVER, P-15, PRIME AND PAINT FLAT BLACK. cl NOTE: SEE PLUMBING PLANS FOR GREASE TRAP DETAIL TYPICAL SECTION AT MANHOLE AROUND TRANSITION TYP. ALL 3'-0" AROUND AGGREGATE BASE COURSE ASPHALT PAVEMENT AGGREGATE BASE COURSE FLUSH ASPHALT PAVEMENT FLUSH WASHED STONE ALL AROUND NON-WOVEN FILTER FABRIC 1" DIA. WEEPHOLE (4 REQ'D.) TYPICAL SECTION AT INLET/CATCH BASIN ASPHALT PAVING SECTION. SEE 27 C-402 8"8" TYPICAL SECTION @ BASINS NOT TO SCALE 45 C-403 SCREENED REFUSE ENCLOSURE NOT TO SCALE 38 C-403 REFUSE ENCLOSURE PLAN NOTES: 1. SEE SITE PLAN FOR LAYOUT OF CONC. LOADING PAD. 2. SEE GRADING PLAN FOR ELEVATIONS ON DUMPSTER PAD & DRAINAGE OF INTERIOR TRASH ENCLOSURE. 3. PROVIDE POSITIVE DRAINAGE ON APPROACH PAD AWAY FROM DUMPSTER. 4. SEE ARCHITECTURAL PLANS FOR ADDITIONAL DETAILS ON ENCLOSURE; COORDINATE & VERIFY SIZE WITH ARCHITECT & STRUCTURAL ENGINEER. 5. GENERAL CONTRACTOR SHALL DRILL HOLES FOR GATE PINS IN BOTH THE OPEN & CLOSED POSITION.SAW JOINT2'-0"TYP.2'-0" TYP.SAW JOINTEQUAL 6" THICK 4000 PSI CONCRETEAPPROACH PAD WITH #3's @12" ON CENTER EACH WAY35'-0" 37 C-403 TOP/SLAB (SEE FDN. PLAN)4"U.N.O.BLDG. LINE SEE FDN. PLAN FOR REINF. 5'-0" MIN. MATCH SIDEWALK SECTION FOR CONCRETE (4" MIN.) 6"x6"x6 GAUGE WELDED WIRE FABRIC SEATED AND SECURED ON STANDS 2"PCC SIDEWALK IF REQUIRED MAX. 1.5% SLOPE 2" XPS RIGID FOAM INSULATION MATCH SIDEWALK SECTION FOR AGGREGATE BASE (4" MIN.) PREPARED AND COMPACTED SUBGRADE NOTE: 1. CONTRACTOR HAS THE OPTION TO DRILL, SET AND EPOXY GROUT DOWEL, IF NOT INSTALLED WHEN THE BUILDING SLAB WAS POURED. 2. REFER TO ARCHITECTURAL DRAWINGS FOR DOOR LOCATIONS DOOR STOOP SHALL EXTEND 12" PAST EACH SIDE OF DOOR MIN. STOOP TO BE SEPARATED ON ALL SIDES WITH 1/4" EXPANSION JOINT MATERIAL, TOPPED WITH SEALANT 3. USE A 10'X5' SLAB MINIMUM AT A DOUBLE DOOR ENTRY. 4. USE A 5'X5' SLAB MINIMUM AT A SINGLE DOOR ENTRY. 5. DOWELS TO BE INSTALLED INTO THE BUILDING FOUNDATION ONLY. THE REMAINING THREE SIDES OF THE SLAB DO NOT GET TIED TO THE SURROUNDING SIDEWALK. ENTRY DOOR FROST SLAB DETAIL NOT TO SCALE 1/2" DIA DOWEL @ 2'-0" ON CENTER DOWEL TO BE SET AT TIME OF BUILDING SLAB POUR OR DRILL, SET, EPOXY GROUT DOWEL INTO EXISTING SLAB X X X X 6" MIN. X X 6" MIN. ALIGN EDGE OF SLAB TO CLOSEST JOINT OR BACK OF CURB DRIVE-THRU PLAN - FLUSH WITH FFE NOT TO SCALE 42 C-403 0'-6" 1'-0" 45°C.J.C.J.C.J. 2.0%X-SLOPE19'-0" LANDING 15'-0" RAMP 12'-0"19'-0" LANDING 38'-0" 2'-0" CHAMFER C.J.6" HEADER CURB END 24" CURB & GUTTER 6"Ø BOLLARD CONCRETE DRIVE-THRU LANE VARIES PER BUILDING EL. = 0" EL. = 0" EL. = 0"EL. = -2" EL. = -8" EL. = -8" EL. = -2" FACE OF BUILDING 15'-0" RAMP FACE OF CURB NOTE: 1. ALL ELEVATIONS ON THIS DETAIL ARE RELATIVE TO FFE = 0'. 2. FOR LC FOOTPRINT DECREASE LANDING FROM 38' TO 30'. LANDING SHOULD REMAIN CENTERED ON DRIVE-THRU WINDOW. 6" HEADER CURB 24" CONCRETE CURB & GUTTER C.J.DRIVE THRU BUMP 19'-0" LANDING 9'-6" TYP ON LANDING 43 C-403 DRIVE-THRU ISOMETRIC NOT TO SCALE R AMP U P R AMP D N 1 2' 1 2' 6" CON CR E T E P A V E M E N T O F DRI V E T H R U C ENTE R LI N E 12' 1 '-0 "CR OSS SL O P E 2% CJ CJ CJ 1'-2" 24" CONCRETE CURB & GUTTER 6" AGGREGATE BASE COURSE SEE NOTE #1. NOTE: 1. GENERAL CONTRACTOR SHALL REFERENCE GEOTECHNICAL REPORT FOR PAVEMENT SECTION REQUIREMENTS. 2. FOR LC FOOTPRINT DECREASE LANDING FROM 38' TO 30'. LANDING SHOULD REMAIN CENTERED ON DRIVE-THRU WINDOW. 6" HE ADER CUR B BOLLAR D ASP H A L T PAV E M E N T C ONCR E T E A R E A V ARIAB L E H EI G H T HE ADER C U R B, D RIVE -THRU W IN DOW OR A UTOM A TI C D OOR 12' MI N . TO F A C E O F CUR B DOU B L E L A N E : 25' TO F A C E O F CU R B 2" CJ HE ADER CURB, V ARI ABLE HEIGH T C ONCR E T E AREA B UILDI N G F ACE 1 9' C ONCR E T E L ANDI N G 1 9' C ONCR E T E L ANDI N G CJ CJ SIN G LE LA N E : 10' MI N. WI T H NO CUR B (SE E C I VIL P L A N F O R D I M E N S I O N S ) DRIVE-THRU PLAN - 2" BELOW FFE NOT TO SCALE 44 C-403 0'-6" 1'-0"45°C.J.C.J.C.J.2.0%X-SLOPE10'-0" LANDING 12'-0" RAMP 12'-8"10'-0" LANDING 20'-0" 2'-0" CHAMFER C.J.6" HEADER CURB END CURB & GUTTER 6"Ø BOLLARD CONCRETE DRIVE-THRU LANE 1'-2" EL. = -2" EL. = -2" EL. = -2" EL. = -2" EL. = -8" EL. = -8" EL. = -2" NOTE: ALL ELEVATIONS ON THIS DETAIL ARE RELATIVE TO FFE = 0' FACE OF CURB FACE OF BUILDING 12'-0" RAMP EQUAL EQUAL Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSION AL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION CHICK-FIL-A STANDARD CONSTRUCTION DETAILS C-403 04/20/23 CLEANOUT DETAIL CLEAN-OUT PLUG SQUARE BY GENERAL 6" THICK x 2'-0" CONCRETE PAD 1/8 BEND SANITARY / STORM PIPE CONTRACTOR CLEANOUT COVER BT VALCO, INC OR APPROVED EQUAL 24" CONCRETE CURB & GUTTER CONCRETE FOR RADIUS PROTECTION SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 3000 P.S.I. AT 28 DAYS. SUBBASE PREPARED AND COMPACTED TO A MINIMUM DENSITY OF 95% MODIFIED PROCTOR OR AS SPECIFIED BY A GEOTECHNICAL ENGINEER SEE NOTE #1 RADIUS PROTECTION APRON SHALL MEET THE MINIMUM LENGTH AND WIDTH DIMENSIONS AS PROVIDED ON THE SITE PLAN. EXPANSION JOINTS AT 20' MAX. & ALL P.C.s, UNLESS APPROVED OR INDICATED OTHERWISE ON PLAN VIEW JOINT PATTERN. PAVEMENT DIMENSION REFER TO FACE OF CURB UNLESS INDICATED OTHERWISE CONTRACTION JOINTS AT 5' MAX. SPACING 90° 90°2'R(TYP.)3.0' MIN.CROSS SECTION PLAN VIEW 3.0'12"LIGHT BROOM FINISH NOTE: 1. GENERAL CONTRACTOR SHALL REFERENCE GEOTECHNICAL REPORT FOR PAVEMENT SECTION REQUIREMENTS. SEE GEOTECHNICAL REPORT FOR THICKNESS OF AGGREGATE UNDERNEATH PAVEMENT AND CURB AND GUTTER EXPANSION JOINT LANDSCAPE & IRRIGATION PROTECTOR NOT TO SCALE 49 C-404 11 C-400 24 C-401 50 C-404 SOLID PLASTIC WHEEL STOP NOT TO SCALE 6'-0 "4-12"7" (3) 8" LAGS FOR CONCRETE PAVEMENT OR 12" GALVANIZED PLATED SPIKES FOR ASPHALT PAVEMENT REQUIRED FOR EACH WHEEL STOP. SEE MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION. NOTES: 1. MATERIAL: SOLID POLYETHYLENE 2. WHEEL STOP COLOR: YELLOW 3. MANUFACTURER - PLASTICS-R-UNIQUE, INC. 352 MILL STREET WADSWORTH, OH 44281 CONTACT - BOBBIE PERTIE 330-334-4820 PHONE 330-334-4720 FAX 4. USE ONLY MANUFACTURER SUPPLIED LAGS AND SPIKES 5. PRE-DRILL HOLES THROUGH PARKING SURFACES (3 4" BIT FOR LAGS AND 38" BIT FOR SPACES) 6. FILL PRE-DRILLED HOLES WITH HEAVY DUTY CONSTRUCTION ADHESIVE SUCH AS PL400 2'-0"2'-0"NOTE: WHEEL STOPS ONLY TO BE USED WHEN NO OTHER PRACTICAL OPTION EXISTS MEAL DELIVERY AREA - DT LANE STRIPING NOT TO SCALE 48 C-404 DRIVE-THRU STRIPING NOT TO SCALE 47 C-404 STORM WEEP HOLE DETAIL (PROFILE VIEW) NOT TO SCALE 51 C-404 STORM WEEP HOLE DETAIL (PLAN VIEW) NOT TO SCALE 52 C-404 PRE-CAST CATCH BASIN PER D.O.T. HEAVY DUTY TRAFFIC RATING. CONFORMING TO ASTM C478 FABRIC OR EQUAL NON-WOVEN FILTER MIRAFI 140N PROFILE VIEW MIRAFI 140N NON-WOVEN FILTER FABRIC OR EQUAL 1" DIA. WEEPHOLE (4 REQ'D.) (3 REQ'D. AT CURB INLETS) PRE-CAST CATCH BASIN PER D.OT. HEAVY DUTY TRAFFIC RATING. CONFORMING TO ASTM C478 CATCH BASIN / MANHOLE FRAME & GRATE PLAN VIEW 1" DIA. WEEPHOLE (4 REQ'D) (3 REQ'D. AT CURB INLETS) NOTE: REQUIRED AT ALL STORM SEWER STRUCTURES LOCATED WITHIN PAVED AREAS NOTE: REQUIRED AT ALL STORM SEWER STRUCTURES LOCATED WITHIN PAVED AREAS BASE COURSE AGGREGATE (PER PAVEMENT TYPICAL SECTION) EXISTING SUBBASE PRECAST CONCRETE STRUCTURE WASHED STONE BASE COURSE AGGREGATE (PER PAVEMENT TYPICAL SECTION) BASE COURSE AGGREGATE (PER PAVEMENT TYPICAL SECTION) DISTANCE BETWEEN RIM ELEVATION AND TOP OF WEEP HOLE: - STRUCTURES ≥ 4' DIA.: 2.5' - STRUCTURES < 4' DIA.: 2.0' DISTANCE BETWEEN RIM ELEVATION AND TOP OF WEEP HOLE: - STRUCTURES ≥ 4' DIA.: 2.5' - STRUCTURES < 4' DIA.: 2.0' Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFES SIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION CHICK-FIL-A STANDARD CONSTRUCTION DETAILS C-404 04/20/23 SEASONAL HIGH GROUNDWATER TABLE 4. WASHOUT AREA(S) SHALL BE INSTALLED IN A LOCATION EASILY ACCESSIBLE BY CONCRETE TRUCKS. 5. ONE OR MORE AREAS MAY BE INSTALLED ON THE CONSTRUCTION SITE AND MAY BE RELOCATED AS CONSTRUCTION PROGRESSES. 6. AT LEAST WEEKLY REMOVE ACCUMULATION OF SAND AND AGGREGATE AND DISPOSE OF PROPERLY. NOTES: 1. CONTAINMENT MUST BE STRUCTURALLY SOUND AND LEAK FREE AND CONTAIN ALL LIQUID WASTES. 2. CONTAINMENT DEVICES MUST BE OF SUFFICIENT QUANTITY OR VOLUME TO COMPLETELY CONTAIN THE LIQUID WASTES GENERATED. 3. WASHOUT MUST BE CLEANED OR NEW FACILITIES CONSTRUCTED AND READY TO USE ONCE WASHOUT IS 75% FULL. 10 MIL SHEETINGPOLYETHYLENE 12" MIN ALL AROUND WASHOUT SIGNPLAN TYPICAL SECTION CHANNEL POST AT WASHOUT AREAIN A PROMINENT LOCATION SIGN SHALL BE PLACED FINISH GRADE 3'-0" MIN SOIL EMBEDMENT 7'-0" TO BOTTOM OF SIGN GALVANIZED "U" BACKGROUND ON WHITE BLACK LETTERS12"18" SHALLWASHOUT HERE ALL CONCRETETRUCKS AGGREGATE 12" MAX 18"± EXISTING GRADE (TYPICAL) 6" MIN EMBEDMENT AGGREGATE 6" MIN DEPTH 30"± 10 MIL WOOD STAKE (TYPICAL) SHEETING POLYETHYLENE VARIES10' MIN. ANCHOR SHEETING WITH 2"x2"x4' STAKES AS NEDDED CONCRETE WASHOUT AREA Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFES SIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION EROSION CONTROL DETAILS C-500 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFES SIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION STANDARD CONSTRUCTION DETAILS C-501 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFES SIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION STANDARD CONSTRUCTION DETAILS C-502 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFES SIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION STANDARD CONSTRUCTION DETAILS C-503 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFES SIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION STANDARD CONSTRUCTION DETAILS C-504 04/20/23 Information contained on this drawing and in all digital files produced for above named project may not be reproduced in any manner without express written or verbal consent from authorized project representatives. ENGINEER'S PROJECT # PRINTED FOR DATE SHEET SHEET NUMBER DRAWN BY: Chick-fil-A 5200 Buffington Road Atlanta, Georgia 30349-2998 REVISION SCHEDULE FSR#CHICK-FIL-A210531 ISSUED FOR CONSTRUCTION 07/21/2022WEST CARMEL (IN) FSUISSUED FOR CONSTRUCTION04978 NO. DATE DESCRIPTION CHECKED BY: MRJ JFV 9965 N. MICHIGAN ROADCARMEL, IN 460321 01/12/23 ISSUED FOR PERMIT PROFESSIONAL E N GINE ERJO SEPHF.VAVRINA ,IIIREGISTERED INDIAN A No. PE11800597 STATE OF 2 02/17/23 PER CITY COMMENTS 3 03/01/23 PER TRICO COMMENTS 4 03/24/23 ISSUED FOR CONSTRUCTION EX-300 EMERGENCY FLOOD ROUTING EXHIBIT FOR CONSTRUCTION 04/20/23