Loading...
HomeMy WebLinkAboutE201 LIGHTING DETAILSARC1 LED Architectural Wall Luminaire Catalog Number Notes Type Hit the Tab key or mouse over the page to see all interactive elements. Introduction Specifications Depth (D1): D2 6.5" Depth (D2): Height: Width: Weight: (without options) 4.75" 5" 11" 7 lbs W D1 H The Lithonia Lighting ARC LED wall-mounted luminaires provide both architectural styling and visually comfortable illumination while providing the high energy savings and low initial costs for quick financial payback. ARC1 delivers up to 3,000 lumens with a soft, non-pixelated light source, creating a visually comfortable environment. The compact size of ARC1, with its integrated emergency battery backup option, is ideal for over-the-door applications. ARC LED Family Overview Luminaire ARC1 LED ARC2 LED Standard EM, 0°C 4W 4W Cold EM, -20°C P1 -- 8W 1,500 1,500 Ordering Information Series ARC1 LED Package P1 1,500 Lumens P2 2,000 Lumens P3 3,000 Lumens Color Temperature 30K 3000K 40K 50K 4000K 5000K Voltage MVOLT 347 1 Options E4WH PE DMG P2 2,000 2,000 Approximate Lumens (4000K) P3 3,000 3,000 P4 -- 4,000 P5 -- 6,500 EXAMPLE: ARC1 LED P2 40K MVOLT PE DDBXD Finish Emergency battery backup, CEC compliant (4W, 0°C min) 1 Button type photocell for dusk-to-dawn operation 0-10V dimming wires pulled outside fixture (for use with an external control, ordered separately) 2 SPD6KV 6kV surge protection FAO Field adjustable light output device. Allows for easy adjustment to the desired light levels, from 20% to 100% 2 DDBXD DBLXD DNAXD DWHXD DSSXD DDBTXD DBLBXD DNATXD Dark bronze Black Natural aluminum White Sandstone Textured dark bronze Textured black Textured natural aluminum DWHGXD Textured white DSSTXDTextured sandstone AccessoriesOrdered and shipped separately. WSBBW DDBXD USurface - mounted back box (specify finish) NOTES 1 347V not available with E4WH. 2 FAO not available with DMG. COMMERCIAL OUTDOOR One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2020-2022 Acuity Brands Lighting, Inc. All rights reserved. ARC1 LED Rev. 03/02/22 Performance Data Lumen Output Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Performance Package P1 P2 P3 30K (3000K, 80 CRI) System Watts 11W 17W 25W Lumens 1,376 2,035 2,859 LPW 127 121 117 B 0 1 1 U 0 0 0 G 0 1 1 Lumens 1,454 2,151 3,021 40K (4000K, 80 CRI) LPW 134 128 123 B 0 1 1 U 0 0 0 G 0 1 1 Lumens 1,464 2,165 3,041 50K (5000K, 80 CRI) LPW 135 129 124 B 0 1 1 U 0 0 0 G 0 1 1 Electrical Load Performance Package P1 P2 P3 System Watts 11W 17W 25W 120V 0.111 0.139 0.208 208V 0.061 0.081 0.122 Current (A) 240V 0.053 0.071 0.108 Lumen Output in Emergency Mode (4000K, 80 CRI) 277V 0.047 0.063 0.097 347V 0.045 0.060 0.081 Option E4WH Lumens 620 Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Ambient 0°C 10°C 20°C 25°C 30°C 40°C 32°F 50°F 68°F 77°F 86°F 104°F Lumen Multiplier 1.04 1.02 1.01 1.00 0.99 0.97 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours 0 Lumen Maintenance Factor 0.97 25,000 >0.96 50,000 >0.95 100,000 >0.91 Photometric Diagrams LEGEND 0.25 fc 0.5 fc 3.0 fc 1.0 fc MH = 10ft Grid = 10ft x 10ft ARC1 LED P3 40K To see complete photometric reports or download .ies files for this product, visit the Lithonia Lighting ARC LED homepage. Tested in accordance with IESNA LM-79 and LM-80 standards. COMMERCIAL OUTDOOR One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2020-2022 Acuity Brands Lighting, Inc. All rights reserved. ARC1 LED Rev. 03/02/22 Emergency Egress Options Emergency Battery Backup The emergency battery backup is integral to the luminaire — no external housing required! This design provides reliable emergency operation while maintaining the aesthetics of the product. All emergency battery backup configurations include an independent secondary driver with an integral relay to immediately detect loss of normal power and automatically energize the luminaire. The emergency battery will power the luminaire for a minimum duration of 90 minutes (maximum duration of three hours) from the time normal power is lost and maintain a minimum of 60% of the light output at the end of 90minutes. Applicable codes: NFPA 70/NEC – section 700.16, NFPA 101 Life Safety Code Section 7.9 The example below shows illuminance of 1 fc average and 0.1 fc minimum in emergency mode. Grid = 10ft x 10ft ARC1 LED 40K MVOLT E4WH Mounting, Options & Accessories Self-contained solution for clean aesthetic E4WH – 4W Emergency Battery Backup BBW – Standard Back Box D = 6.5” H = 5” W = 11” D = 1.5” H = 4” W = 5.5” For surface conduit applications. 3/4" conduit entry holes. FEATURES & SPECIFICATIONS INTENDED USE The clean architectural shape of the ARC LED was designed for applications such as hospitals, schools, malls, restaurants, and commercial buildings. The long-life LEDs and driver make this luminaire nearly maintenance-free. CONSTRUCTION The die-cast aluminum housing and door act as heat sinks to optimize thermal transfer from the light engine and driver to promote long-life. The die-cast door frame is fully gasketed with a one-piece solid silicone gasket to keep out moisture and dust, providing an IP65 rating for the luminaire. FINISH Exterior painted parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures a 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peeling. Standard Super Durable colors include dark bronze, black, natural aluminum, sandstone and white. Available in textured and non-textured finishes. OPTICS Recessed lens to cut off high angle light and reduce glare. Combination of diffused lens and reflector design has low surface brightness creating a visually comfortable environment with great distribution. LEDs are fully hidden from view to eliminate pixelization and harsh glare. The ARC LED has zero uplight and qualifies as a Nighttime Friendly™ product, meaning it is consistent with the LEED® and Green Globes™ criteria for eliminating wasteful uplight. ELECTRICAL Light engine consists of high-efficacy LEDs mounted to metal-core circuit boards to maximize heat dissipation and promote long-life (up to L91/100,000 hours at 25°C). The electronic driver has a power factor of >90%, THD <20%. Luminaire is 0-10V dimmable. INSTALLATION The universal wall plate, supplied with the luminaire, fits multiple size junction boxes and supports the luminaire during wiring for easy installation. Built-in wet location wiring compartment on the luminaire to accommodate wiring connections for where there is no junction box. Design can withstand up to a 1.5 G vibration load rating per ANSI C136.31. LISTINGS CSA certified to U.S. and Canadian standards. Luminaire is IP65 rated. DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified. International DarkSky Association (IDA) Fixture Seal of Approval (FSA) is available for all products on this page utilizing 3000K color temperature only. Rated for -40°C minimum ambient. WARRANTY 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. COMMERCIAL OUTDOOR One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2020-2022 Acuity Brands Lighting, Inc. All rights reserved. ARC1 LED Rev. 03/02/22 ARC2 LED Architectural Wall Luminaire Catalog Number Notes Type Hit the Tab key or mouse over the page to see all interactive elements. Introduction Specifications Depth (D1): D2 9.25" Depth (D2): Height: Width: Weight: (without options) 7.5" 5"W 14" 11 lbs D1 H The Lithonia Lighting ARC LED wall-mounted luminaires provide both architectural styling and visually comfortable illumination while providing the high energy savings and low initial costs for quick financial payback. ARC2 delivers up to 6,500 lumens with a soft, non-pixelated light source, creating a visually comfortable environment. It offers integrated emergency battery backup options, including an 8W cold temperature option, making it suitable for pedestrian scale applications in any environment. ARC LED Family Overview Luminaire ARC1 LED ARC2 LED Standard EM, 0°C 4W 4W Cold EM, -20°C P1 -- 8W 1,500 1,500 Ordering Information Series ARC2 LED Package P1 1,500 Lumens P2 2,000 Lumens P3 3,000 Lumens P4 4,000 Lumens P5 6,500 Lumens Color Temperature 30K 3000K 40K 50K 4000K 5000K Voltage MVOLT 347 1 Options E4WH E8WC PE DMG P2 2,000 2,000 Approximate Lumens (4000K) P3 3,000 3,000 P4 -- 4,000 P5 -- 6,500 EXAMPLE: ARC2 LED P2 40K MVOLT PE DDBXD Finish Emergency battery backup, CEC compliant (4W, 0°C min) 1 Emergency battery backup, CEC compliant (8W, -20°C min) 1 Button type photocell for dusk-to-dawn operation 0-10V dimming wires pulled outside fixture (for use with an external control, ordered separately) 2 FAO Field adjustable light output device. Allows for easy adjustment to the desired light levels, from 20% to 100% 2 DDBXD DBLXD DNAXD DWHXD DSSXD DDBTXD DBLBXD DNATXD Dark bronze Black Natural aluminum White Sandstone Textured dark bronze Textured black Textured natural aluminum DWHGXD Textured white DSSTXDTextured sandstone Accessories NOTES Ordered and shipped separately. WSBBW DDBXD USurface - mounted back box (specify finish) 1 347V not available with E4WH, E8WC and SPD6KV. 2 FAO not available with DMG. COMMERCIAL OUTDOOR One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2020-2022 Acuity Brands Lighting, Inc. All rights reserved. ARC2 LED Rev. 03/02/22 Performance Data Lumen Output Lumen values are from photometric tests performed in accordance with IESNA LM-79-08. Data is considered to be representative of the configurations shown, within the tolerances allowed by Lighting Facts. Contact factory for performance data on any configurations not shown here. Performance Package P1 P2 P3 P4 P5 30K (3000K, 80 CRI) System Watts 11W 16W 24W 30W 51W Lumens 1,502 2,250 3,206 3,903 6,260 LPW 142 140 135 128 122 B 0 0 0 1 1 U 0 0 0 0 0 G 1 1 1 1 1 Lumens 1,587 2,377 3,387 4,124 6,615 40K (4000K, 80 CRI) LPW 150 147 143 136 129 B 0 0 0 1 1 U 0 0 0 0 0 G 1 1 1 1 1 Lumens 1,598 2,393 3,410 4,152 6,659 50K (5000K, 80 CRI) LPW 151 148 144 136 130 B 0 0 0 1 1 U 0 0 0 0 0 G 1 1 1 1 1 Electrical Load Performance Package P1 P2 P3 P4 P5 System Watts 11W 16W 24W 30W 51W 120V 0.090 0.141 0.202 0.280 0.471 208V 0.055 0.081 0.117 0.162 0.272 Current (A) 240V 0.049 0.072 0.103 0.144 0.239 Lumen Output in Emergency Mode (4000K, 80 CRI) 277V 0.046 0.064 0.091 0.128 0.212 347V 0.045 0.059 0.079 0.095 0.158 Option E4WH E8WC Lumens 693 1,413 Lumen Ambient Temperature (LAT) Multipliers Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Ambient 0°C 10°C 20°C 25°C 30°C 40°C 32°F 50°F 68°F 77°F 86°F 104°F Lumen Multiplier 1.04 1.03 1.01 1.00 0.99 0.97 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours 0 Lumen Maintenance Factor 1.0 25,000 >0.96 50,000 >0.93 100,000 >0.88 Photometric Diagrams LEGEND 0.25 fc 0.5 fc 3.0 fc 1.0 fc MH = 15ft Grid = 15ft x 15ft ARC2 LED P3 40K To see complete photometric reports or download .ies files for this product, visit the Lithonia Lighting ARC LED homepage. Tested in accordance with IESNA LM-79 and LM-80 standards. COMMERCIAL OUTDOOR One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2020-2022 Acuity Brands Lighting, Inc. All rights reserved. ARC2 LED Rev. 03/02/22 Emergency Egress Options Emergency Battery Backup The emergency battery backup is integral to the luminaire — no external housing required! This design provides reliable emergency operation while maintaining the aesthetics of the product. All emergency battery backup configurations include an independent secondary driver with an integral relay to immediately detect loss of normal power and automatically energize the luminaire. The emergency battery will power the luminaire for a minimum duration of 90 minutes (maximum duration of three hours) from the time normal power is lost and maintain a minimum of 60% of the light output at the end of 90minutes. Applicable codes: NFPA 70/NEC – section 700.16, NFPA 101 Life Safety Code Section 7.9 The example below shows illuminance of 1 fc average and 0.1 fc minimum in emergency mode. Grid = 10ft x 10ft ARC2 LED 40K MVOLT E4WH ARC2 LED 40K MVOLT E8WC Mounting, Options & Accessories Self-contained solution for clean aesthetic E4WH and E8WC – Emergency Battery Backup BBW – Standard Back Box D = 6.5” H = 5” W = 11” D = 1.5” H = 4” W = 5.5” For surface conduit applications. 3/4" conduit entry holes. FEATURES & SPECIFICATIONS INTENDED USE The clean architectural shape of the ARC LED was designed for applications such as hospitals, schools, malls, restaurants, and commercial buildings. The long-life LEDs and driver make this luminaire nearly maintenance-free. CONSTRUCTION The die-cast aluminum housing and door act as heat sinks to optimize thermal transfer from the light engine and driver to promote long-life. The die-cast door frame is fully gasketed with a one-piece solid silicone gasket to keep out moisture and dust, providing an IP65 rating for the luminaire. FINISH Exterior painted parts are protected by a zinc-infused Super Durable TGIC thermoset powder coat finish that provides superior resistance to corrosion and weathering. A tightly controlled multi-stage process ensures a 3 mils thickness for a finish that can withstand extreme climate changes without cracking or peeling. Standard Super Durable colors include dark bronze, black, natural aluminum, sandstone and white. Available in textured and non-textured finishes. OPTICS Recessed lens to cut off high angle light and reduce glare. Combination of diffused lens and reflector design has low surface brightness creating a visually comfortable environment with great distribution. LEDs are fully hidden from view to eliminate pixelization and harsh glare. The ARC LED has zero uplight and qualifies as a Nighttime Friendly™ product, meaning it is consistent with the LEED® and Green Globes™ criteria for eliminating wasteful uplight. ELECTRICAL Light engine consists of high-efficacy LEDs mounted to metal-core circuit boards to maximize heat dissipation and promote long-life (up to L88/100,000 hours at 25°C). The electronic driver has a power factor of >90%, THD <20%. Luminaire is 0-10V dimmable. INSTALLATION The universal wall plate, supplied with the luminaire, fits multiple size junction boxes and supports it during wiring for easy installation. Built-in wet location wiring compartment on the luminaire to accommodate wiring connections for applications with no junction box. Design can withstand up to a 1.5 G vibration load rating per ANSI C136.31. LISTINGS CSA certified to U.S. and Canadian standards. Luminaire is IP65 rated. DesignLights Consortium® (DLC) Premium qualified product and DLC qualified product. Not all versions of this product may be DLC Premium qualified or DLC qualified. Please check the DLC Qualified Products List at www.designlights.org/QPL to confirm which versions are qualified. International DarkSky Association (IDA) Fixture Seal of approval (FSA) is available for all products on this page utilizing 3000K color temperature only. Rated for -40°C minimum ambient. WARRANTY 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/terms-and-conditions Note: Actual performance may differ as a result of end-user environment and application. All values are design or typical values, measured under laboratory conditions at 25 °C. Specifications subject to change without notice. COMMERCIAL OUTDOOR One Lithonia Way • Conyers, Georgia 30012 • Phone: 1-800-705-SERV (7378) • www.lithonia.com © 2020-2022 Acuity Brands Lighting, Inc. All rights reserved. ARC2 LED Rev. 03/02/22 SPD6KV 6kV surge protection 1 ISSUE FOR PERMIT 9025 River Road, Suite 200 | Indianapolis, Indiana 46240 TEL 317.547.5580 | FAX 317.543.0270 www.structurepoint.com PLOT DATE: 5/30/2024 2:32 PMPLOT SCALE: 1:2.5849EDIT DATE: 9/19/2023EDITED BY: NWINSLOWDRAWING FILE: P:\2017\02968\D. Drawings\Civil\Construction Documents\Tru Hotel\2017.02968.CE.TRU.C600.SD.dwgProject Number CERTIFIED BY ISSUANCE INDEX DATE: PROJECT PHASE: 04/17/2024 2017.02968 TRU HOTEL 12164 N. MERIDIAN ST. CARMEL, INDIANA DORA HOSPITALITY, LLC 9904 NORTH BY NORTHEAST BLVD FISHERS, IN 46037 REVISION SCHEDULE NO.DESCRIPTION DATE APPROVAL PENDING NOT FOR CONSTRUCTION IN SUBMITTING BIDS IN RELIANCE ON THESE PLANS THE CONTRACTOR ASSUMES ALL RISKS OF ADDITIONAL COSTS OF REVISIONS DUE TO REQUIREMENTS OF THE OWNER OR GOVERNMENTAL AUTHORITIES AND MATERIAL REVISIONS IN THE COURSE OF COMPLETING THE FINAL DESIGN. E201 LIGHTING DETAILS