Loading...
HomeMy WebLinkAboutA104 - FOURTH FLOOR PLANF.E.C.F.E.C.DNUPDNUPG1A301_______________1A301_______________2A301_______________2A301_______________1A302_______________A2011A2013A2012A201423456789101112131415161718192021FEDCBASTORAGE401STAIR #1402CORRIDOR403HOUSEKEEPING406MECH405STAIR #2417ELEV. LOBBY404UNIT AG401RIGHTKINGUNIT BG403LEFTQUEEN/QUEENUNIT BG405RIGHTQUEEN/QUEENUNIT AG407LEFTLEFTUNIT AG409RIGHTKINGUNIT AG411LEFTKINGUNIT AG413RIGHTKINGUNIT B1G419RIGHTQUEEN/QUEENUNIT DG421LEFTQUEEN/QUEENUNIT BG423RIGHTQUEEN/QUEENUNIT BG425LEFTQUEEN/QUEENUNIT AG427RIGHTKINGUNIT AG429LEFTKINGUNIT AG431LEFTKINGUNIT AG430RIGHTKINGUNIT BG428LEFTQUEEN/QUEENUNIT BG426RIGHTQUEEN/QUEENUNIT BG424LEFTQUEEN/QUEENUNIT CG422RIGHTKINGUNIT B1G420LEFTQUEEN/QUEENUNIT BG418RIGHTQUEEN/QUEENUNIT AG416LEFTKINGUNIT AG414RIGHTKINGUNIT AG412LEFTKINGUNIT AG410RIGHTKINGUNIT AG408LEFTKINGUNIT AG406RIGHTKINGUNIT BG404LEFTQUEEN/QUEENUNIT BG402RIGHTQUEEN/QUEENA5029A5031A5034A50332A302_______________9' - 6 1/2"11' - 8"11' - 8"11' - 8"11' - 8"11' - 8"11' - 8"11' - 8"11' - 8"11' - 8"11' - 8"11' - 8"15' - 2"11' - 8"11' - 8"11' - 8"11' - 8"8' - 11 3/8"2' - 8 5/8"3 3/8"3 3/8"2' - 1"4' - 5"21' - 6 3/4"5' - 7 3/4"21' - 6 3/4"4' - 5"3 3/8"AABA2A2A2AA2BB2B1AAAA2AAA2BA2AAA2BAAEBW1W1W1W1W1W1W1CW1W1W1W1W1W1W1W1W1W1W1W1W1CBBBB404401W1406405402417W14A302_______________3A304_______________3A304_______________A4012A3074A30843A303_______________1A304_______________ABAW1W1W1W1AABAB2B2A54' - 1 3/4"4' - 0 1/4"25' - 0 3/4"23' - 10 3/4"69' - 5 1/4"74' - 0 3/4"23' - 10 3/4"4' - 5"W174' - 0 3/4"11' - 0 5/8"W1W1W12' - 1"4' - 5"27' - 9 1/4"25' - 11 3/4"60' - 3"24' - 8"3' - 1 1/4"B2B223' - 10 3/4"69' - 5 1/4"23' - 4"15' - 8 3/4"23' - 4"35' - 0"10' - 1 3/8"2 PANELS @ 1'-10"13' - 9 3/8"1' - 11 3/8"2' - 1"4' - 5"3A302_______________NOTES:-ROOMS FOR HEARING IMPAIRED TO BE PROVIDED WITH VISIBLE & AUDIBLE ALARM PER THE ELECTRICAL DESIGN DRAWINGS. DEVICES SHALL BE ACTIVATED BY BOTH THE IN-ROOM SMOKE DETECTOR AND THE BUILDING FIRE PROTECTION SYSTEM.-SEE ROOM FINISH SCHEDULE FOR SHELVING REQUIREMENTS.-WALL, FLOOR, & ROOF ASSEMBLIES ARE INDICATED WITH . SEE VERTICAL & HORIZONTAL ASSEMBLY SHEETS FOR MORE INFO.1. THIS PLAN SHOWS THE LOCATIONS OF ITEMS THAT ARE ARCHITECTURALLY SIGNIFICANT ONLY. PLUMBING, MECHANICAL, AND ELECTRICAL ITEMS INDICATED ARE REFERENCE ONLY.2. SEE MEP PLANS FOR EXACT LOCATIONS AND DETAILS. SEE THE A500 SHEETS FOR THE GUESTROOM CEILING PLANS.3. CONTRACTOR HAS OPTION TO USE GYP BD SUSP SYSTEM OR LIGHT GAGE METAL FRAMING AT DROPPED GYP BD CEILING LOCATIONS.4. SUSP CLG TO BE CENTERED W/ BALANCE GRID DESIGN W/ EDGE UNITS NO LESS THAN 50% OF TILE SIZE5. SEE SHEET G002 FOR GENERAL ARCHITECTURE NOTES & G003/G004 FOR RATED AREAS6. AT STUCCO -DISTANCE BETWEEN CONTROL JOINTS SHOULD NOT EXCEED 18 FEET IN EITHER DIRECTION WITH A LENGTH TO WIDTH RATIO OF 2.5 TO 1.7. SOFFITS (AND ANY ENCLOSED SPACE AREA) TO BE FRAMED WITH STL STUDS.1. GYP BD W/ PAINTED FINISH (NO TEXTURE)2. GYP BD @ WET AREAS W/ PAINTED FINISH3. EXPOSED STRUCTURE ABOVE -PAINTED4. 2X2 PREMIUM TEGULAR (REVEAL) EDGE ACOUSTICAL CEILING TILE WITH 9/16" NARROW SPLINE GRID SYSTEM5. 2X2 ACOUSTICAL CEILING TILE -1/2" VINYL FACE WITH STANDARD 15/16" GRID SYSTEM6.EIFS -COLOR TO MATCH ADJACENT WALL7.DECORATIVE WOOD BEAM MILLWORKRCP GENERAL NOTESRCP PLAN KEY NOTESLEGEND0'-0"CEILING HEIGHT TAGGYP BD CEILING -DO NOT EXCEED 200 SF BETWEEN CONTROL JOINTS 2' x 2' SUSPENDED ACOUSTICAL CEILING TILE2' x 4' CLEANABLE VINYL FACED SUSPENDED ACOUSTICAL CEILING TILE2' x 4' SUSPENDED ACOUSTICAL CEILING TILEEIFS FINISH CEILING -DO NOT EXCEED 100 SF BETWEEN CONTROL JOINTS (HORIZONTAL APPLICATION)METAL PANEL -COLOR: PANTONE PMS 4525METAL PANEL -COLOR: PANTONE PMS 5405STORAGE401STAIR #1402HOUSEKEEPING406MECH405STAIR #2417ELEV. LOBBY404UNIT AG401RIGHTKINGUNIT BG403LEFTQUEEN/QUEENUNIT BG405RIGHTQUEEN/QUEENUNIT AG407LEFTLEFTUNIT AG409RIGHTKINGUNIT AG411LEFTKINGUNIT AG413RIGHTKINGUNIT B1G419RIGHTQUEEN/QUEENUNIT DG421LEFTQUEEN/QUEENUNIT BG423RIGHTQUEEN/QUEENUNIT BG425LEFTQUEEN/QUEENUNIT AG427RIGHTKINGUNIT AG429LEFTKINGUNIT AG431LEFTKINGUNIT AG430RIGHTKINGUNIT BG428LEFTQUEEN/QUEENUNIT BG426RIGHTQUEEN/QUEENUNIT BG424LEFTQUEEN/QUEENUNIT CG422RIGHTKINGUNIT B1G420LEFTQUEEN/QUEENUNIT BG418RIGHTQUEEN/QUEENUNIT AG416LEFTKINGUNIT AG414RIGHTKINGUNIT AG412LEFTKINGUNIT AG410RIGHTKINGUNIT AG408LEFTKINGUNIT AG406RIGHTKINGUNIT BG404LEFTQUEEN/QUEENUNIT BG402RIGHTQUEEN/QUEENCORRIDOR403A5032A5022SimA4032PLAN NORTHTRUE NORTHDRAWN BY:CHECKED BY:© Copyright 2021 - Cities Edge, LLC. - All rights reservedSHEETNUMBERThis document contains confidential or proprietary information of Cities Edge, LLC. Neither this document nor the information herein is to be reproduced, distributed, used or disclosed either in whole or in part except as authorized by Cities Edge, LLC. PROJECTNUMBERSHEET TITLE:PROJECT TITLE:ISSUEPHASEDATEISSUEDPROJECT OWNER:PROJECT LOCATION:Certification & Seal:5-29-2024C:\Users\sbents\OneDrive - Cities Edge Architects,LLC\Documents\20-033_ARCH_Tru_Carmel_IN_Central_R23_sbentsUU5H6.rvt5/29/2024 10:22:20 AM20-033AuthorCheckerA104FOURTH FLOOR PLAN3/20/2023Dora Hospitality50% SUBMITTALCARMEL, INTRUSCALE: 1/8" = 1'-0"1FOURTH FLOORSCALE: 1/8" = 1'-0"2FOURTH FLOOR REFLECTED CEILING PLANRevision Date