Loading...
HomeMy WebLinkAboutA504 - UNIT D & D1 - ACCESSIBLE QUEEN-QUEEN1415DAEXTERIOR FINISH VARIES -SEE EXT. ELEVS.GRIDGRIDGRIDGRIDAENTRYBBATHROOMCBEDROOM2 3/4"14' - 8 1/2"2 3/4"4' - 9 1/4"9' - 11 1/4"8 1/8"27' - 10"2 3/4"9' - 9 3/4"18' - 8 3/8"14' - 6" CLEAR MINIMUM12' - 4 5/8"27' - 6" CLEAR MINIMUMCAEAETTACTTABA55011A50467855' - 2 7/8"9' - 5 5/8"1415DAEXTERIOR FINISH VARIES -SEE EXT. ELEVS.GRIDGRIDGRIDGRIDAENTRYBBATHROOMCBEDROOMA5045Sim6Sim7Sim8Sim2 3/4"14' - 8 1/2"2 3/4"4' - 9 1/4"9' - 11 1/4"8 1/8"27' - 10"2 3/4"18' - 8 3/8"9' - 9 3/4"5' - 2 7/8"9' - 5 5/8"27' - 6" CLEAR MINIMUM12' - 4 5/8"14' - 6" CLEAR MINIMUMCW1AEAETTTTBAACA55067' -6"28' -0"1EQEQEQEQ1' - 5"2' - 0"EQEQEQEQPT-02PT-0146127' -6"18' -0"1PT-29PT-013527FLOOR:VF-06BASE:B-01FLOOR:T-01BASE:B-0211998FLOOR:T-04@ ROLL-IN SHOWER25OS-014OS-015GR-601GR-307GR-214OS-010GR-200OS-0162022222221GR-2192OS-011GR-222GR-220GR-102GR-22322GR-311GR-80122GR-403GR-3061GR-310GR-216GR-206.ADAGR-705OS-018QOS-019QGR-206.ADAGR-705OS-018QOS-019QGR-216GR-218OS-013GR-309OS-012GR-310HOLD2' - 9"CLEAR3'-0" MIN34' - 0"SPA-01B-01351' - 6"SPA-02SPA-013' - 0"HOLD1' - 2 1/2"B-01CD-01PT-033"4' - 0"15164' - 0" MAX1' - 6"3' - 10"SPA-01B-01CD-01SPA-01PT-31SPA-016' - 10"1' - 5"1' - 6"3' - 10"8"3' - 2"8' - 0"6"2' - 11"4' - 2"3' - 6"TO TOP4' - 0" MAXSPA-01231' - 6"B-0120211. THIS PLAN SHOWS THE LOCATIONS OF ITEMS THAT ARE ARCHITECTURALLY SIGNIFICANT ONLY. PLUMBING, MECHANICAL, AND ELECTRICAL ITEMS INDICATED ARE REFERENCE ONLY.2. SEE MEP PLANS FOR EXACT LOCATIONS AND DETAILS. SEE THE A500 SHEETS FOR THE GUESTROOM CEILING PLANS.3. CONTRACTOR HAS OPTION TO USE GYP BD SUSP SYSTEM OR LIGHT GAGE METAL FRAMING AT DROPPED GYP BD CEILING LOCATIONS.4. SUSP CLG TO BE CENTERED W/ BALANCE GRID DESIGN W/ EDGE UNITS NO LESS THAN 50% OF TILE SIZE5. SEE SHEET G002 FOR GENERAL ARCHITECTURE NOTES & G003/G004 FOR RATED AREAS6. AT STUCCO -DISTANCE BETWEEN CONTROL JOINTS SHOULD NOT EXCEED 18 FEET IN EITHER DIRECTION WITH A LENGTH TO WIDTH RATIO OF 2.5 TO 1.7. SOFFITS (AND ANY ENCLOSED SPACE AREA) TO BE FRAMED WITH STL STUDS.1. GYP BD W/ PAINTED FINISH (NO TEXTURE)2. GYP BD @ WET AREAS W/ PAINTED FINISH3. EXPOSED STRUCTURE ABOVE -PAINTED4. 2X2 PREMIUM TEGULAR (REVEAL) EDGE ACOUSTICAL CEILING TILE WITH 9/16" NARROW SPLINE GRID SYSTEM5. 2X2 ACOUSTICAL CEILING TILE -1/2" VINYL FACE WITH STANDARD 15/16" GRID SYSTEM6.EIFS -COLOR TO MATCH ADJACENT WALL7.DECORATIVE WOOD BEAM MILLWORKRCP GENERAL NOTESRCP PLAN KEY NOTESLEGEND0'-0"CEILING HEIGHT TAGGYP BD CEILING -DO NOT EXCEED 200 SF BETWEEN CONTROL JOINTS 2' x 2' SUSPENDED ACOUSTICAL CEILING TILE2' x 4' CLEANABLE VINYL FACED SUSPENDED ACOUSTICAL CEILING TILE2' x 4' SUSPENDED ACOUSTICAL CEILING TILEEIFS FINISH CEILING -DO NOT EXCEED 100 SF BETWEEN CONTROL JOINTS (HORIZONTAL APPLICATION)METAL PANEL -COLOR: PANTONE PMS 4525METAL PANEL -COLOR: PANTONE PMS 5405GUESTROOM GENERAL NOTES1. ALL HEARING IMPAIRED SUITES SHALL HAVE BOTH AUDIBLE & VISUAL FIRE ALARM DEVICES. PROVIDE IN EVERY SPACE IN THE SUITE: BEDROOM, BATH, LIVING/DINING (IF THERE IS NO DOOR BETWEEN THE LIVING/DINING AND BEDROOM, ONE AUDIBLE/VISUAL ALARM MAY BE SUFFICIENT), THE FIXTURES MUST BE LOCATED SO THAT THE LIGHT IS VISIBLE IN EACH SPACE.2. SEE OVERALL FLOOR PLANS FOR LOCATIONS OF UNITS WITH CONNECTING DOORS.3. ALL UNITS WITH ROLL-IN SHOWERS TO HAVE FLOOR WATERPROOFING/CRACK MEMBRANE THROUGH-OUT RESTROOM. MEMBRANE TO WRAP UP WALLS AND BE SEALED AT FLOOR DRAIN LOCATIONS IN ORDER TO MAINTAIN WATER PROOF INTEGRITY.4. ALL FLOOR TILE IN ADA RESTROOMS TO HAVE SLIP COEFFECIENT.5. TYP ELECTRICAL OUTLET HEIGHTS (U.N.O.)-TYPICAL WALL OUTLET: 18" AFF-BATHROOM VANITY OUTLET: 48" AFF-ADA BATHROOM VANITY OUTLET: 44" AFF6. STRUCTURAL AND MEP ITEMS SHOWN FOR REFERENCE ONLY -REFER TO PLANS7. SEE INTERIOR DESIGN DRAWINGS FOR INTERIOR FINISHES/FURNISHINGS.REMOVE NOTE 7 IF ID ISIN-OFFICEGUESTROOM KEY NOTES:HARDWIRED PTAC UNITTV MOUNT ATTACHED TO WALL MOUNTED CASEGOOD FRAME; COORDINATE ANCHORING REQUIREMENTS WITH MANUFACTURERROLLER SHADE TREATMENT MOUNTED TO FACE OF WINDOW WALL -SHEER ROLLER SHADE INSTALLED AT ROOM SIDEMINIMUM CEILING HEIGHT MUST BE MAINTAINEDBLACKOUT ROLLER SHADE AND BLACKOUT SIDE/SILL CHANNELS INSTALLED AT WINDOW SIDE FLUSH AGAINST WINDOW MULLIONSRECESSED CEILING LIGY FIXTURE FOR WET LOCATION WITH SHATTER PROOF LENSWALL MOUNTED LIGHT FIXTURE TO BE SWITCHED -REFER TO ELECTRICAL PLAN FOR J-BOX LOCATION AND INTERIOR ELEVATIONS FOR MOUNTING HEIGHTEDGE OF PTAC ABOVE FLOORINGSTART FLOOR PATTERN WITH FILL TILE AT THIS LOCATIONSEPARATE DATA AND CCTV OUTLETFLOOR FINISH NOT PROVIDED UNDER PRE-MANUFACTURED SHOWER PANCEILING DIMENSION COORDINATES TO CASEGOODS AND HANGBAR HEIGHT -DO NOT MODIFYGROUPED DEVICES: CENTERLINE INDICATES DEVICES ARE TO BE ON CENTER AND IN ALIGNMENT WITH ONE ANOTHER -GROUPED DEVICES ARE DIMENSIONED TO CENTER OF GROUPING -REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL INFORMATION AND MOUNTING HEIGHTSRECESSED SWITCHED OUTLET FOR ILLUMINATED MIRROR (SWITCHED WITH BATHROOM DOWNLIGHTS)LOCATION OF EVACUATION MAP AND/OR ADDITIONAL ROOM SIGNAGE AS REQUIRED BY LOCAL JURISDICTIONSINTERIOR SIGNAGEELECTRICAL DEVICES REQUIRED TO BE INSTALLED WITHIN CASEGOOD CUTOUTS AS INDICATEDDOORBELL ON/OFF SWITCH -SIGNAGE AS REQUIREDWALL MOUNTED WIRELESS ACCESS POINT (WAP) -VERIFY WAP WILL FIT IN 8" OPENING AS SHOWN. CABLE RUNS FOR WAP MUST BE 4X4 PAIR CABLES (CAT6-RJ45) TERMINATED IN 8POIN RJ-45 FEMALE JACKS AT THE ACCESS POINT IN EACH GUESTROOM -A SECOND CABLE TO BE PULLED TO EACH GUESTROOM WHEN WITED INTERNET IS ALSO PROVIDEDOPTIONAL DOOR FOR CONNECTING ROOMS -REFER TO OVERALL PLANS FOR LOCATION OF CONNECTING DOORSCASEGOODS MUST BE ADJUSTED IF CONNECTING DOOR IS NEEDED -REFER TO ENLARGED PLANSDESIGNATED REQUIRED CLEAR FLOOR SPACE PER CODESWITCHES CONTROLLING MECHANICAL SHADES IN ACCESSIBLE ROOMS -ELECTRICIAN MUST COORDINATE WITH WINDOW TREATMENT FABRICATORWIRELESS THERMOSTAT FOR PTAC MOUNTED 48" MAX TO TOP OF DEVICE (ACCESSIBLE ROOMS ONLY)WALL SCONCE AT ACCESSIBLE ROOM MUST NOT PROJECT MORE THAN 4" FROM WALL; HARDWIRE FIXTURE TO WALL; CONTACTOR TO VERIFY J-BOX TYPE TO ENSURE PROPER INSTALLATIONPROVIDE OPTIONAL BARN DOOR BATHROOM ENTRY IF JURISDICTION DOES NOT ALLOW FOR DOOR SWING INTO BATHROOMPROVIDE J-BOX FOR AUTOMATIC WINDOW ROLLER SHADES WITH SWITCHED DEVICE FOR OPERATION IN ACCESSIBLE ROOMS (VERIFY LOCATION OF J-BOX WITH ROLLER SHADE MANUF.); COORDINATE LOCATION OF SWITCH WITH ELECTRICAL PLANS.123456789101112131415161718192021222324252627DRAWN BY:CHECKED BY:© Copyright 2021 - Cities Edge, LLC. - All rights reservedSHEETNUMBERThis document contains confidential or proprietary information of Cities Edge, LLC. Neither this document nor the information herein is to be reproduced, distributed, used or disclosed either in whole or in part except as authorized by Cities Edge, LLC. PROJECTNUMBERSHEET TITLE:PROJECT TITLE:ISSUEPHASEDATEISSUEDPROJECT OWNER:PROJECT LOCATION:Certification & Seal:5-29-2024C:\Users\sbents\OneDrive - Cities Edge Architects,LLC\Documents\20-033_ARCH_Tru_Carmel_IN_Central_R23_sbentsUU5H6.rvt5/29/2024 10:15:48 AM20-033AuthorCheckerA504UNIT D & D1 -ACCESSIBLEQUEEN/QUEEN3/20/2023Dora Hospitality50% SUBMITTALCARMEL, INTRULEFTVERISION OF UNIT IS BEING SHOWN. VERIFY LEFT/RIGHT COUNTS OF EACH UNIT. SCALE: 1/4" = 1'-0"1UNIT D - FLOOR PLANSCALE: 1/4" = 1'-0"9UNIT D1 - FLOOR PLANSCALE: 1/4" = 1'-0"2UNIT D - REFLECTED CEILING PLANSCALE: 1/4" = 1'-0"3UNIT D - FLOOR FINISH PLANSCALE: 1/4" = 1'-0"4UNIT D - FURNITURE PLANSCALE: 1/4" = 1'-0"5UNIT D - INTERIOR ELEVATIONSCALE: 1/4" = 1'-0"6UNIT D - INTERIOR ELEVATIONSCALE: 1/4" = 1'-0"7UNIT D - INTERIOR ELEVATIONSCALE: 1/4" = 1'-0"8UNIT D - INTERIOR ELEVATIONGUEST UNIT D FF&E SCHEDULEFURN TAG #DESCRIPTIONQUANTITYGR-102 TASK CHAIR1GR-200 LUGGAGE BENCH1GR-206.ADA ACCESSIBLE QUEEN BED BASE2GR-214 LANDING ZONE FIXTURE @ ADA ROOMS 1GR-216 QUEEN HEADBOARD2GR-218 QUEEN NIGHTSTAND1GR-219 TV WALL UNIT WITH INTEGRATED POWER 1GR-220 LAMINATE WALL PANELS @ TV WALL 1GR-222 ELONGATED STORAGE BENCH1GR-223 MOBILE DESK1GR-306 FLOOR LAMP1GR-307 WALL SCONCE @ FULL LENGTH MIRROR 1GR-309 BEDSIDE LAMP1GR-310 ACCESSIBLE HEADBOARD SCONCE 2GR-311 ACCESSIBLE WALL SCONCE @ DESK 1GR-403 MOTORIZED ROLLER SHADE SET1GR-601 FULL LENGTH MIRROR1GR-705 QUEEN BEDSKIRT2GR-801 WASTE BASKET1OS-010 REFRIGERATOR - OWNER SUPPLIED 1OS-011 TELEVISION - OWNER SUPPLIED1OS-012 PHONE - OWNER SUPPLIED1OS-013 ALARM CLOCK - OWNER SUPPLIED 1OS-014 IRON - OWNER SUPPLIED1OS-015 IRONING BOARD - OWNER SUPPLIED 1OS-016 HANGERS - OWNER SUPPLIED1OS-018Q QUEEN MATTRESS - OWNER SUPPLIED 2OS-019Q QUEEN BEDDING - OWNER SUPPLIED 2Revision Date