HomeMy WebLinkAboutC303 - GRADING PLAN (BASEBALL)1.TOPSOIL SHALL BE STRIPPED FROM ALL AREAS TO RECEIVE PAVING AND FROM WITHIN THE LIMITSOF PROPOSED BUILDINGS AND STRUCTURES. TOPSOIL SHALL BE STRIPPED TO THE DEPTH SHOWNIN THE GEOTECHNICAL REPORT, OR TO A DEPTH OF 6 INCHES, WHICHEVER IS GREATER.2.TOPSOILSHALL BE PLACED TO A DEPTH OF 4 TO 6 INCHES IN ALL AREAS TO BE SEEDED OR SODDEDPER THE SPECIFICATIONS.3.EXCESS TOPSOIL MAY BE PLACED IN MOUNDING AREAS AND NONSTRUCTURAL FILL AREAS ASAVAILABLE.4.ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE SEEDED OR SODDED UNLESS OTHERWISESHOWN.5.FINAL GRADES AT THE PROJECT BOUNDARY SHALL MATCH EXISTING ELEVATIONS UNLESSOTHERWISE SHOWN.6.THE CONTRACTOR SHALL PERFORM AN EARTHWORK QUANTITY ANALYSIS PRIOR TO COMMENCINGCONSTRUCTION TO CONFIRM SUCH QUANTITIES WITH THE ENGINEER. ADJUSTMENTS TO PROPOSEDFINISH GRADES BASED UPON THE EARTHWORK QUANTITY ANALYSIS SHALL BE APPROVED BY THEENGINEER.SILVARA COURT DOM
I
NO
D
R
I
V
E
CLAY CENTER ROAD
NO PARKING NO PARKING
NO PARK
I
N
G
NO PARKING
FFE =
86
6
.6
0
FFE =866.0HW 100
:
8
55
.
9
NORMA
L
:
85
1
.0
85' W
I
DE
EM
E
RG
EN
CY
SPILLW
AYW/ RIP R
AP
REVET
M
EN
T
C
OV
ER
DRAINAGE & BMP ESMT
REMOV
E
T
RE
E
S
&
G
R
AD
E
4' W SW
AL
E
T
O
P
RO
V
ID
E
POSITI
V
E
D
RA
I
NA
GE
20'W BM
P
A
C
CE
S
S
E
SM
T
20'W BM
P
AC
CES
S
ES
M
T25'W SAN S
WR
E
SMT
25'W SA
N
S
W
R
E
SM
T
25'W
S
AN
SW
R
E
S
MT
25'W SA
N
SW
R E
S
MT
30'W DRAINAGE ESMTPROPOSED ROWPROPOSED ROW20' BMP
AC
CE
S
S
EASE
ME
N
T
20'W
E
LE
C
ES
MT10'W GA
S
ES
M
T
20'W W
AT
E
R
E
SM
T
20'W SAN SWR ESMT 20'W SAN SWR ESMT
WETL
AN
DS(PROT
EC
T)FR
FR FRFRFRFRFRFRFRFR
FR FRFRFR
FRFRFR
FR
FR FRFR FRFR
FRFR
FRFRFRFRFRFR
FR
FR
FR
FR
FR FRFR FRFR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR FR FR
FR
FRFR FRFR
FRFRFR FR FRFR
FRFRFRFR FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR FRFRFRFRFRFRFR
FRFR
FR
FR
FR FRFRFRFRFRFRFRFR
FR FRFRFR
FRFRFR
FR
FR FRFR FRFR
FRFR
FRFRFRFRFRFR
FR
FR
FR
FR
FR FRFR FRFR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR FR FR
FR
FRFR FRFR
FRFRFR FR FRFR
FRFRFRFR FR
FR
FR
FR
FR
FR
FR
FR
FR
FR
FR FRFRFRFRFRFRFR
FRFR
FR
WETLANDS(PROTECT)WETLANDS(PROTECT)CLAY CENTER ROAD EEEEEEEEEEEEEEEEEEEEEEEEEEEE866866866866
866866 866866 NO PARKINGFFE = 866.6085
7
858
856856860859863862864865866867866867868869869868
FFE =866.0REMOVE TREES & GRADE4' W SWALE TO PROVIDEPOSITIVE DRAINAGE855.6855.125'W SAN SWR ESMT25'W SAN SWR ESMTPROPOSED ROW724DRIM=867.30721RIM=865.25720RIM=865.60712RIM=864.00713RIM=864.00711RIM=864.00706RIM=864.00707RIM=864.00708RIM=864.00705RIM=864.00709RIM=864.00710RIM=864.00RIM=862.20704ARIM=858.04429' OF 12" PVC@0.25%222' OF 12" PVC@0.25%60' OF 15" RCP@0.41%309' OF 15" RCP@0.47%60' OF 15" RCP@0.58%309' OF 18" RCP@0.55%60' OF 12" RCP@1.24%@0.47%174' OF 36" RCP@0.47%59' OF 12" RCP@3.99%26' OF 12" RCP@0.59%309' OF 15" RCP@1.13%16
9
'
O
F
2
4
"
R
C
P
@
0
.
5
1
%
51' OF 15" RCP@1.38%
36' OF 15" RCP
@1.39%
60' OF 18" RCP
@0.58%45' OF 24" RCP@0.51%16
9
'
O
F
2
4
"
R
C
P
@
0
.
5
1
%70' OF 36" RCP@0.46%717ARIM=864.00167RIM=865.98INV=858.70INV =858.00744INV =855.10745INV=855.6010'W GAS ESMT429' OF 12" PVC@0.25%222' OF 12" PVC@0.25%20'W SAN SWR ESMT865
862
860
86
0
865
857858859860860MFPG: 865.10MLAG: 866.58MFPG: 865.10MLAG: 865.33FRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFR863862861860857
856859
860
861
863
862864856858863860862861859
FRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRFRPROPOSEDGRADING LIMITS(TYP)PROPOSEDGRADING LIMITS(TYP)PROPOSEDGRADING LIMITS(TYP)TREE PROTECTIONFENCE (TYP)DEFINITIONS OF (PER CITY OF CARMEL STORMWATER TECHNICAL STANDARDS MANUAL):MINIMUM FLOOD PROTECTION GRADE (MFPG) OF ALL STRUCTURES FRONTING A POND OROPEN DITCH SHALL BE NO LESS THAN 2 FEET ABOVE ANY ADJACENT 100-YEAR LOCAL ORREGIONAL FLOOD ELEVATIONS, WHICHEVER IS GREATER, FOR ALL WINDOWS, DOORS,PIPE ENTRANCES, WINDOW WELLS, AND ANY OTHER STRUCTURE MEMBER WHEREFLOODWATERS CAN ENTER A BUILDING.FOR ALL STRUCTURES LOCATED IN THE SPECIAL FLOOD HAZARDS AREA (SFHA) AS SHOWNON FEMA MAPS, THE LOWEST FLOOR ELEVATIONS OF ALL RESIDENTIAL, COMMERCIAL, ORINDUSTRIAL BUILDINGS SHALL HAVE LOWEST FLOOR ELEVATION, INCLUDING BASEMENT,AT THE FLOOD PROTECTION GRADE AND THEREFORE HAVE AT LEAST 2 FEET OF FREEBOARDABOVE THE 100-YEAR FLOOD ELEVATION.MINIMUM LOWEST ADJACENT GRADE (MLAG) FOR ALL RESIDENTIAL, COMMERCIAL, ORINDUSTRIAL BUILDINGS OUTSIDE A FEMA OR IDNR DESIGNATED FLOODPLAIN SHALL HAVE2 FEET OF FREEBOARD ABOVE THE FLOODING SOURCE'S 100-YEAR FLOOD ELEVATIONUNDER PROPOSED CONDITIONS. LOWEST ADJACENT GRADE IS THE ELEVATION OF THELOWEST GRADE ADJACENT TO A STRUCTURE, WHERE THE SOIL MEETS THE FOUNDATIONAROUND THE OUTSIDE OF THE STRUCTURE (INCLUDING STRUCTURAL MEMBERS SUCH ASBASEMENT WALKOUT, PATIOS, DECKS, PORCHES, SUPPORT POSTS OR PIERS, AND RIM OFWINDOW WELL).FOR AREAS OUTSIDE A FEMA OR IDNR DESIGNATED FLOODPLAIN, THE LOWEST ADJACENTGRADE (INCLUDING WALKOUT BASEMENT FLOOR ELEVATION) FOR ALL RESIDENTIAL,COMMERCIAL, OR INDUSTRIAL BUILDINGS ADJACENT TO PONDS SHALL BE A MINIMUM OF2 FEET ABOVE THE 100-YEAR POND ELEVATION OR 2 FEET ABOVE THE EMERGENCYOVERFLOW WEIR ELEVATION, WHICHEVER IS HIGHER. IN ADDITION TO THE LOWESTADJACENT GRADE REQUIREMENTS, ANY BASEMENT FLOOR SHALL BE AT LEAST 1 FOOTABOVE THE PERMANENT WATER LEVEL (NORMAL POOL ELEVATION).:13800801F.F.E.L.Pt.H.Pt.%1.00FRINV.=800.50T.C.B.C.771.20770.70772.4772.40M.E.772.4FL MATCH EXISTING PAVEMENT SPOT GRADE GROUND SPOT GRADE TOP OF CURB AND BOTTOM OF CURB H:V RATIO GRADE PIPE INVERT ELEVATION FLOOD ROUTE FLOW LINE SPOT GRADE POND CONTOUR POND BOTTOM POND NORMAL POOL LOW POINT INTERMEDIATE CONTOUR INDEX CONTOUR GRADE BREAK FINISHED FLOOR ELEVATION HIGH POINT EXISTING INTERMEDIATE CONTOUR EXISTING INDEX CONTOUR FLOW DIRECTION w/GRADEGRADING NOTESGRADING PLAN LEGENDLINE TYPE / SYMBOLDESCRIPTIONLINE TYPE / SYMBOLDESCRIPTIONSCALE: 1" = 30'18095Project Number:Drawing Number:Certified By:Checked ByDrawn ByIssue DateRevisions:PROJECT:Scope Drawings:CARMEL, INDIANA
NEW
FOR
CARMEL CLAY SCHOOLS
CARMEL ELEMENTARY SCHOOLSDrawing Title:06-21-19SOMKRev. #RevisionDescriptionIssueDateKEYMAPC303C303GRADING PLAN(BASEBALL) SWALE2TAC COMMENTS8/12/20194ASI #29/20/20193ASI #18/28/20191ADDENDUM7/9/2019ASI #812/18/201988888