Loading...
HomeMy WebLinkAboutC513 - PLAN & PROFILE (STORM)FFE = 868.50 FFE = 868.50 WWWWWWWWWWWWWGREASE INTERCEPTOR PER TRI CO STANDARDS C.O. 8" HDPE RD RD 8" HDPE RDRDRDRD 12" HDPE 8" HDPE CONCRETE COLLAR REQUIRED BETWEEN BOT. OF STORM AND TOP OF WATER AND GAS LINES. CONCRETE COLLAR REQUIRED BETWEEN BOT. OF STORM AND TOP OF WATER AND GAS LINES. 8" HDPE 8" HDPE 726A RIM=864.65 726 RIM=864.25 726B RIM=866.10 726C RIM=866.75 725 RIM=865.80 725A RIM=865.25 724 RIM=864.80 724A RIM=866.80 724B RIM=868.00 37' OF 12" RCP @2.47% 119' OF 12" RCP @1.47% 46' OF 30" RCP @0.44% 168' OF 30" RCP @0.45% 119' OF 12" RCP @1.26% 37' OF 12" RCP @2.47%27' OF 12" RCP @3.72%162' OF 24" RCP@0.46%721B RIM=864.40 43' OF 15" RCP @0.81% 725B RIM=866.8330' OF 12" HDPE@3.37%725C RIM=867.41 61' OF 12" RCP @0.47% 726D RIM=866.51 STR. #725 MANHOLE, 5' DIA.; R-1772TC: 865.80INV. IN 858.30 (30" RCP (N))INV. IN 860.95 (15" RCP (E))INV. OUT 858.20 (30" RCP (S))STR. #726 MH 5' DIA.; R-3286-8VTC: 864.25INV. IN 859.15 (24" RCP (N))INV. IN 859.50 (12" RCP (W))INV. IN 859.40 (12" RCP (NE))INV. OUT 859.05 (30" RCP (S))STR. #724 MH 5' DIA.; R-3010TC: 864.80INV. IN 858.00 (30" RCP (N))INV. IN 859.00 (12" RCP (W))INV. OUT 857.90 (30" RCP (S)) 168' 0.45% 30" RCP 46' 0.44% 30" RCP STR. #726 MH 5' DIA.; R-3286-8VTC: 864.25INV. IN 859.15 (24" RCP (N))INV. IN 859.50 (12" RCP (W))INV. IN 859.40 (12" RCP (NE))INV. OUT 859.05 (30" RCP (S)) 162' 0.46% 24" RCP STR. #727 MH 5' DIA.; R-3010TC: 865.15INV. IN 860.85 (12" RCP (E))INV. IN 860.40 (12" RCP (N))INV. IN 860.00 (12" RCP (W))INV. OUT 859.90 (24" RCP (S)) 86' 0.93% 12" RCP STR. #728 MH 4' DIA.; R-3010TC: 866.35INV. IN 861.30 (12" RCP (E))INV. OUT 861.20 (12" RCP (S)) 78' 0.58% 12" RCP STR. #729 INLET AM; R-3405TC: 865.00INV. OUT 861.75 (12" RCP (W))HGL (10-YR) HGL (10-YR) HGL (10-YR) HGL (10-YR) FFE = 868.50FHV WWWWWWWWWRDRDRD C.O. C.O. RD RDRDRD 8" HDPE C.O. RDRDRD 8" HDPE 8" HDPE RD RD CONCRETE COLLAR REQUIRED BETWEEN BOT. OF STORM AND TOP OF WATER AND GAS LINES. 5 LF OF 10" HDPE 5 LF OF 10" HDPE 727B RIM=868.60 727 RIM=865.15 726A RIM=864.65 726B RIM=866.10 726C RIM=866.75 728 RIM=866.35 727A RIM=866.00 729 RIM=865.00 727D RIM=865.85 119' OF 12" RCP @1.26% 37' OF 12" RCP @2.47%27' OF 12" RCP @3.72%162' OF 24" RCP@0.46%37' OF 12" RCP @2.47% 123' O F 1 2 " R C P @0.69 % 25' OF 12" RCP @3.00%86' OF 12" RCP@0.93%78' OF 12 " R C P @0.58%NO PARKING61' OF 12" RCP @0.47% 726D RIM=866.51 737D RIM=868.2086' OF 12" HDPE @0.58% 86' OF 12" HDPE @0.58% 737 RIM=867.6756' OF 12" HDPE@0.54%735 RIM=867.4148' OF 12" HDPE@0.63%736 RIM=866.90 18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK Rev. #Revision Description Issue Date 1 ADDENDUM 7/9/2019 3 ASI #1 8/28/2019 STORM SEWER PLAN STORM SEWER PROFILE ALIGNMENT 724-726 ALIGNMENT 726-729 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. GENERAL NOTES SCALE: 1" = 30' SCALE:HORZ.: 1"=30' VERT.: 1"=5' LEGEND Existing Grade New Grade Granular Backfill C513 PLAN & PROFILE (STORM) 2 TAC COMMENTS 8/12/2019 4 ASI #2 9/20/2019 44 4 4 4 4 4 NOTE* INSTALL FULL DEPTH GRANULAR BACKFILL WHEN UTILITY IS WITHIN 5' OF PAVEMENT. SEE C603, DETAIL 10-31.4 4