Loading...
HomeMy WebLinkAboutC515 - PLAN & PROFILE (STORM) 119' 1.26% 12" RCP 37' 2.47% 1 2 " R C P 27' 3.72% 12" RCPSTR. #726 MH 5' DIA.; R-3286-8VTC: 864.25INV. IN 859.15 (24" RCP (N))INV. IN 859.50 (12" RCP (W))INV. IN 859.40 (12" RCP (NE))INV. OUT 859.05 (30" RCP (S))STR. #726B MH 4' DIA.; R-3010TC: 866.10INV. IN 861.10 (12" RCP (W))INV. OUT 861.00 (12" RCP (E))STR. #726C INLET M; R-3010TC: 866.75INV. OUT 862.00 (12" RCP (E))STR. #726A MH 4' DIA.; R-3286-8VTC: 864.65INV. IN 860.60 (12" RCP (E))INV. OUT 860.40 (12" RCP (SW))STR. #731 MH 5' DIA.; R-3286-8VTC: 865.00INV. IN 855.45 (24" RCP (N))INV. IN 860.00 (12" RCP (W))INV. OUT 855.35 (24" RCP (S))STR. #165 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 868.20INV. OUT 863.90 (12" HDPE (E)) 96' 0.52% 12" HDPE STR. #731A MANHOLE, 4' DIA.; R-1772TC: 867.65INV. IN 863.40 (12" HDPE (W))INV. OUT 863.30 (12" RCP (E)) 111' 2.9 9 % 1 2 " R C P 61' 0.47% 12" RCP STR. #726D INLET AM; R-3405TC: 866.51INV. OUT 860.89 (12" RCP (W))8" PVC INV. ELEV:853.41 HGL (10-YR) HGL (10-YR) HGL (10-YR) HGL (10-YR) FFE = 868.50 WWWWWWWWWWWWPROPOSED ROWRD RD RD RDRDRD8" HDPE CONCRETE COLLAR REQUIRED BETWEEN CONCRETE COLLAR REQUIRED BETWEEN BOT. OF STORM AND TOP OF WATER AND GAS LINES. 727 RIM=865.15 726A RIM=864.65 726 RIM=864.25 726B RIM=866.10 726C RIM=866.75 727D RIM=865.85 168' OF 30" RCP @0.45% 119' OF 12" RCP @1.26% 37' OF 12" RCP @2.47%27' OF 12" RCP @3.72%162' OF 24" RCP@0.46%@0.69 % 725C RIM=867.41 61' OF 12" RCP @0.47% 726D RIM=866.51 86' OF 12" HDPE @0.58% 86' OF 12" HDPE @0.58% 737 RIM=867.6756' OF 12" HDPE@0.54%735 RIM=867.4148' OF 12" HDPELat Lat C.O.RDC.O.C.O. C.O. RD RD RD RD RD RD C.O.TYPE I C.O.TYPE I C.O.TYPE I 8" HDPE Lat 8" HDPE C.O. RD RD RD C.O. RD RD RD 8" HDPE 8" HDPE LatC.O.TYPE I 5 LF OF 10" HDPE 5 LF OF 10" HDPE L a t 20'W SAN SWR ESMT731 RIM=865.00 732 RIM=865.00 732B RIM=866.50 732A RIM=866.50 95' OF 24" RCP @0.53% 100' OF 24" RCP @0.55% 124 ' O F 1 2 " R C P @1 . 9 3 % 38' OF 12" HDPE @0.66% 166' OF 18" RCP @0.72% 67' OF 12" HDPE @1.49% 732C RIM=867.36 111' OF 12" RCP @2.99% 731A RIM=867.6596' OF 12" HDPE @0.52% 165 RIM=868.20 18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK Rev. #Revision Description Issue Date 1 ADDENDUM 7/9/2019 3 ASI #1 8/28/2019 STORM SEWER PLAN STORM SEWER PROFILE ALIGNMENT 726C-726D 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. GENERAL NOTES SCALE: 1" = 30' SCALE:HORZ.: 1"=30' VERT.: 1"=5' LEGEND Existing Grade New Grade Granular Backfill C515 PLAN & PROFILE (STORM) ALIGNMENT 165-731 2 TAC COMMENTS 8/12/2019 4 4 ASI #2 9/20/2019 NOTE* INSTALL FULL DEPTH GRANULAR BACKFILL WHEN UTILITY IS WITHIN 5' OF PAVEMENT. SEE C603, DETAIL 10-31.4