Loading...
HomeMy WebLinkAboutC516 - PLAN AND PROFILE (STORM)WWWWWWWWWPROPOSED ROWCONCRETE COLLAR REQUIRED BETWEEN BOT. OF STORM AND TOP OF WATER AND GAS LINES. 727B RIM=868.60 727 RIM=865.15 726A RIM=864.65 726B RIM=866.10 726C RIM=866.75 728 RIM=866.35 727A RIM=866.00 727D RIM=865.85 119' OF 12" RCP @1.26% 37' OF 12" RCP @2.47%27' OF 12" RCP @3.72%162' OF 24" RCP@0.46%37' OF 12" RCP @2.47% 123' O F 1 2 " R C P @0.69 % 25' OF 12" RCP @3.00%86' OF 12" RCP@0.93%78' OF 1 2 " R C P @0.58%NO PARKING61' OF 12" RCP @0.47%LatLat Lat C.O.RDC.O. C.O. C.O. C.O. RD RD RD RD RD RD C.O.TYPE I C.O.TYPE I C.O.TYPE I C.O.TYPE II RD RD 8" HDPE 8" HDPE Lat 8" HDPE C.O. RD RD RD 8" HDPE RD RD 5 LF OF 10" HDPE L a t 20'W SAN SWR ESMT5 LF OF 10" HDPE 731 RIM=865.00 732 RIM=865.00 732B RIM=866.50 733 RIM=865.00 732A RIM=866.50 100' OF 24" RCP @0.55% 124 ' O F 1 2 " R C P @1 . 9 3 % 38' OF 12" HDPE @0.66% 166' OF 18" RCP @0.72% 67' OF 12" HDPE @1.49% 732C RIM=867.36 111' OF 12" RCP @2.99% 731A RIM=867.6596' OF 12" HDPE @0.52% 165 RIM=868.20 107' O F 1 2 " R C P @2.4 3 % 739 RIM=867.5584' OF 12" HDPE @0.42% 739A RIM=868.20 6" SAN LAT INV = 859.9 37' 2.47% 12" RCP 123' 0.69% 12" RCP 25' 3.00% 12" RCPSTR. #727D MH 4' DIA.; R-3286-8VTC: 865.85INV. IN 861.70 (12" HDPE (E))INV. OUT 861.60 (12" RCP (W))STR. #727 MH 5' DIA.; R-3010TC: 865.15INV. IN 860.85 (12" RCP (E))INV. IN 860.40 (12" RCP (N))INV. IN 860.00 (12" RCP (W))INV. OUT 859.90 (24" RCP (S))STR. #727A MH 4' DIA.; R-3010TC: 866.00INV. IN 860.95 (12" RCP (W))INV. OUT 860.85 (12" RCP (E))STR. #727B INLET M; R-3010TC: 868.60INV. OUT 861.85 (12" RCP (E))STR. #732 MH 5' DIA.; R-3286-8VTC: 865.00INV. IN 856.10 (18" RCP (N))INV. IN 859.75 (12" RCP (NW))INV. OUT 856.00 (24" RCP (S))STR. #732A INLET AM; R-3405TC: 866.50INV. IN 862.25 (12" HDPE (N))INV. IN 862.25 (12" HDPE (W))INV. OUT 862.15 (12" RCP (SE))STR. #732B 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 866.50INV. OUT 862.50 (12" HDPE (S)) 124' 1.93% 1 2 " R C P 38' 0.66% 12" HDPESTR. #732B 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 866.50INV. OUT 862.50 (12" HDPE (S)) 67' 1.49% 12" HD P E STR. #732A INLET AM; R-3405TC: 866.50INV. IN 862.25 (12" HDPE (N))INV. IN 862.25 (12" HDPE (W))INV. OUT 862.15 (12" RCP (SE))STR. #732C 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 867.36INV. OUT 863.25 (12" HDPE (E))8" PVC INV. ELEV:856.39 HGL (10-YR) HGL (10-YR) HGL (10-YR) HGL (10-YR) HGL (10-YR) HGL (10-YR)STR. #732A INLET AM; R-3405TC: 866.50INV. IN 862.25 (12" HDPE (N))INV. IN 862.25 (12" HDPE (W))INV. OUT 862.15 (12" RCP (SE))18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK Rev. #Revision Description Issue Date 1 ADDENDUM 7/9/2019 3 ASI #1 8/28/2019 STORM SEWER PLAN STORM SEWER PROFILE ALIGNMENT 727B-727D ALIGNMENT 732B-732 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. GENERAL NOTES SCALE: 1" = 30' SCALE:HORZ.: 1"=30' VERT.: 1"=5' LEGEND Existing Grade New Grade Granular Backfill C516 PLAN & PROFILE (STORM) ALIGNMENT 732C-732A 2 TAC COMMENTS 8/12/2019 4 4 ASI #2 9/20/2019 NOTE* INSTALL FULL DEPTH GRANULAR BACKFILL WHEN UTILITY IS WITHIN 5' OF PAVEMENT. SEE C603, DETAIL 10-31.4