HomeMy WebLinkAboutC517 - PLAN & PROFILE (STORM)FFE = 868.50 WWWWWWWWWWWFDCWWWWWWWWWWWWWWWWWWWG G G G G G G G G G G G G G G G TS&V T 6"FIREW W W WG GP S 6" GREASE INTERCEPTOR PER TRI CO STANDARDS RIM = 864.82 INV. IN = 860.00 INV. OUT = 859.83 CONCRETE COLLAR REQUIRED BETWEEN BOT. OF STORM AND TOP OF WATER AND GAS LINES. 25'W SAN SWR ESMT WWW W WM WOUTDOOR MECHANICAL YARD RDRD C.O.TYPE II C.O.TYPE II C.O.TYPE IIRDRDRD 12" HDPE 8" HDPE 20'W ELEC ESMT 10'W GAS ESMT 20'W WATER ESMT CONCRETE COLLAR REQUIRED BETWEEN BOT. OF STORM AND TOP OF WATER AND GAS LINES. CONCRETE COLLAR REQUIRED BETWEEN BOT. OF STORM AND TOP OF WATER AND GAS LINES. SAMPLE STRUCTURE RIM = 865.34 INV IN = 859.70 INV OUT = 859.50 8" HDPE 8" HDPE WW OHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUGGGGGGGGGGGGWWWWWWWWWWW725 RIM=865.80 725A RIM=865.25 724 RIM=864.80 724A RIM=866.80 724B RIM=868.00 724C RIM=868.70 723 RIM=866.00 722 RIM=865.25 721 RIM=865.25 721A RIM=866.80 712 711 713 RIM=864.00 26' OF 12" RCP @0.59% 75' OF 30" RCP @0.47%58' OF 12" RCP@2.75%88' OF 30" RCP @0.46%105' OF 12" RCP @1.28 % 37' OF 12" RCP @2.47% 119' OF 12" RCP @1.47% 46' OF 30" RCP @0.44% 168' OF 30" RCP @0.45%NO PARKINGNO PA R KI N G 429' OF 12" PVC @0.25% 721B RIM=864.40 77' OF 12" RCP@0.45%43' OF 15" RCP @0.81% 725B RIM=866.8330' OF 12" HDPE@3.37%725C RIM=867.41 70' OF 36" RCP @0.46% 167 RIM=865.98 38' OF 1 2 " R C P @2.49% 721C RIM=867.80 47' OF 30" RCP @0.42%STR. #724C INLET AM; R-3405TC: 868.70INV. OUT 864.35 (12" RCP (NE)) 105' 1.28% 12" RCP STR. #724B MH 4' DIA.; R-3010TC: 868.00INV. IN 863.00 (12" RCP (SW))INV. OUT 861.75 (12" RCP (E))STR. #724A MH 4' DIA.; R-3010TC: 866.80INV. IN 860.85 (12" RCP (W))INV. OUT 860.75 (12" RCP (E)) 119' 1.47% 12" R C P STR. #724 MH 5' DIA.; R-3010TC: 864.80INV. IN 858.00 (30" RCP (N))INV. IN 859.00 (12" RCP (W))INV. OUT 857.90 (30" RCP (S))STR. #725 MANHOLE, 5' DIA.; R-1772TC: 865.80INV. IN 858.30 (30" RCP (N))INV. IN 860.95 (15" RCP (E))INV. OUT 858.20 (30" RCP (S))STR. #725A MH 4' DIA.; R-3286-8VTC: 865.25INV. IN 861.45 (15" RCP (E))INV. OUT 861.25 (15" RCP (W)) 11' 2.86% 15" RCP 37' 2.47% 12" RCP 43' 0.81% 15" RCPSTR. #725B INLET AM; R-3405TC: 866.83INV. IN 862.00 (12" HDPE (N))INV. OUT 861.80 (15" RCP (W)) 30' 3.37% 12" HDPESTR. #725C 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 867.41INV. OUT 863.00 (12" HDPE (S))HGL (10-YR) HGL (10-YR)HGL (10-YR) HGL (10-YR)STR. #743 15" PIPE END SECTIONTC: 860.24INV. OUT 858.70 (15" RCP (S))STR. #742 15" PIPE END SECTIONTC: 859.54INV. IN 858.00 (15" RCP (N)) 51' 1.38% 15" RCP 9PROPOSED ROWCLAY CENTER ROADE(A)OHUOHUOHUOHUOHUGGGGGWWWWWW51' OF 15" RCP@1.38%5742 INV =858.00 742 INV =858.00 18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK Rev. #Revision Description Issue Date 1 ADDENDUM 7/9/2019 3 ASI #1 8/28/2019 STORM SEWER PLAN STORM SEWER PROFILE ALIGNMENT 724C-724 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. GENERAL NOTES SCALE: 1" = 30' SCALE:HORZ.: 1"=30' VERT.: 1"=5' LEGEND Existing Grade New Grade Granular Backfill C517 PLAN & PROFILE (STORM) ALIGNMENT 725-725A 2 TAC COMMENTS 8/12/2019 4 ASI #2 9/20/2019 NOTE* INSTALL FULL DEPTH GRANULAR BACKFILL WHEN UTILITY IS WITHIN 5' OF PAVEMENT. SEE C603, DETAIL 10-31. ALIGNMENT 743-742 9 ASI #9 01/09/2020