Loading...
HomeMy WebLinkAboutC518 - PLAN & PROFILE (STORM)FFE = 868.50FHVWWWWWW RDRDRD C.O. C.O. RD RDRDRD 8" HDPE C.O. RDRDRD 8" HDPE 8" HDPE RD RD 5 LF OF 10" HDPE 5 LF OF 10" HDPE 729 RIM=865.00 78' OF 12 " R C P 61' OF 12" RCP @0.47% 726D RIM=866.51 737D RIM=868.2086' OF 12" HDPE @0.58% 86' OF 12" HDPE @0.58% 737 RIM=867.6756' OF 12" HDPE@0.54%735 RIM=867.4148' OF 12" HDPE@0.63%736 RIM=866.90 STR. #737D 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 868.20INV. OUT 863.70 (12" HDPE (W))STR. #733 MH 5' DIA.; R-3286-8VTC: 865.00INV. IN 860.86 (12" RCP (W))INV. IN 857.40 (15" RCP (NW))INV. OUT 857.30 (18" RCP (S)) 107' 2.43% 1 2 " R C PSTR. #739 MANHOLE, 4' DIA.; R-1772TC: 867.55INV. IN 863.55 (12" HDPE (W))INV. OUT 863.45 (12" RCP (E)) 84' 0.42% 12" HDPESTR. #739A 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 868.20INV. OUT 863.90 (12" HDPE (E))STR. #721C INLET AM; R-3405TC: 867.80INV. OUT 862.60 (12" RCP (SW))STR. #721A MH 4' DIA.;R-1772TC: 866.80INV. IN 861.65 (12" RCP (NE))INV. IN 860.35 (12" RCP (N))INV. OUT 860.25 (12" RCP (S)) 38' 2.49% 1 2 " R C P 6" PVC INV. ELEV:859.90 6" PVC INV. ELEV:859.00 HGL (10-YR) HGL (10-YR) HGL (10-YR) HGL (10-YR) HGL (10-YR) HGL (10-YR)STR. #737D 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 868.20INV. OUT 863.70 (12" HDPE (W))STR. #737 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 867.67INV. IN 863.20 (12" HDPE (E))INV. OUT 863.10 (12" HDPE (N)) 56' 0.54% 12" HDPE 86' 0.58% 12" HDPESTR. #735 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 867.41INV. IN 862.80 (12" HDPE (S))INV. IN 862.80 (12" HDPE (N))INV. OUT 862.70 (12" HDPE (W))STR. #736 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 866.90INV. OUT 863.10 (12" HDPE (S)) 48' 0.63% 12" HDPE STR. #735 24 INCH NYLOPLAST STRUCTURE, OPEN GRATETC: 867.41INV. IN 862.80 (12" HDPE (S))INV. IN 862.80 (12" HDPE (N))INV. OUT 862.70 (12" HDPE (W))HGL (10-YR)LatLatRD RD C.O. C.O. C.O. C.O. RD RD RD RD RD C.O.TYPE I C.O.TYPE I C.O.TYPE II C.O.TYPE II 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD6''SSD6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSD 6''SSDINV = 864.2 (6"SSD) 8" HDPE 8" HDPE INV = 860.8 RD RD 8" HDPE 8" HDPE Lat RD RD La t 20'W SAN SWR ESMT5 LF OF 10" HDPE 5 LF OF 10" HDPE 5 LF OF 10" HDPE 5 LF OF 10" HDPE 732B RIM=866.50 733 RIM=865.00 732A RIM=866.50 734 RIM=863.50 38' OF 12" HDPE @0.66% 166' OF 18" RCP @0.72%49' OF 15 " RCP@1.12% 49' OF 12" RCP @1.13% 741 RIM=867.29 733A RIM=865.50 67' OF 12" HDPE @1.49% 732C RIM=867.36 107' O F 1 2 " R C P @2.4 3 % 739 RIM=867.5584' OF 12" HDPE @0.42% 739A RIM=868.20 128' OF 15 " RCP@0.94% 6" SAN LAT INV = 859.9 FFE = 868.50 WWWWWWWWWWWFDCWWWWWWWWG G G G LatT 4"6"DOMFIREW W W WG GP WS 6" 25' W S A N S W R E S M T WWW WM WOUTDOOR MECHANICAL YARD RDC.O.RDRD C.O.TYPE II C.O.TYPE II C.O.TYPE II C.O. RD C.O. RDRDRD 12" HDPE 5 LF OF 10" HDPE 5 LF OF 10" HDPE 8" HDPE 8" HDPE RIM=865.25 721 RIM=865.25 721A RIM=866.80 711 RIM=864.00 26' OF 12" RCP @0.59% 60' OF 12" RCP @1.24% 75' OF 30" RCP @0.47% 174' OF 36" RCP58' OF 12" RCP@2.75%NO PARKINGNO PA R KI N G 721B RIM=864.40 77' OF 12" RCP@0.45%165 RIM=868.20 43' OF 15" RCP @0.81% 725B RIM=866.8330' OF 12" HDPE@3.37%725C RIM=867.41 70' OF 36" RCP @0.46% 167 RIM=865.98 38' OF 1 2 " R C P @2.49% 721C RIM=867.80 18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK Rev. #Revision Description Issue Date 1 ADDENDUM 7/9/2019 3 ASI #1 8/28/2019 STORM SEWER PLAN STORM SEWER PROFILE ALIGNMENT 726-737D 1. TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL AND STATE STANDARDS. 2. ALL CONSTRUCTION ACTIVITY ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH APPLICABLE 0.S.H.A. STANDARDS FOR WORKER SAFETY. 3. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY ALL UTILITY LOCATIONS BEFORE CONSTRUCTION BEGINS. 4. CONTRACTORS SHALL MINIMIZE DAMAGE TO EXISTING TREES. GENERAL NOTES SCALE: 1" = 30' SCALE:HORZ.: 1"=30' VERT.: 1"=5' LEGEND Existing Grade New Grade Granular Backfill C518 PLAN & PROFILE (STORM) ALIGNMENT 739A-733 2 TAC COMMENTS 8/12/2019 4 4 4 ASI #2 9/20/2019 NOTE* INSTALL FULL DEPTH GRANULAR BACKFILL WHEN UTILITY IS WITHIN 5' OF PAVEMENT. SEE C603, DETAIL 10-31.4 4