Loading...
HomeMy WebLinkAboutC603 - STORM DETAILS™ Phone (888) 344-9044 Fax (423) 826-2112 2705 Kanasita Drive, Chattanooga, TN 37343 STORMWATER TREATMENT SOLUTIONS www.aquashieldinc.com Aqua-Swirl Concentrator Model AS-10 CFD PCS Standard Detail AS-10 PCS STD 01/20/11 Scale: Drawn By: Document: Date: JCW 1:30 U.S. Patent No. 6524473 and other Patent Pending * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. 5 3/8" [137 mm] 5/8" [15 mm] 1 3/16" [30 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Soil 1 3/16" [30 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Soil Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Riser Frame Cover 57 5/8" [1463 mm] Min. 14 3/8" [366 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Concrete Concrete 9 5/8" [244 mm] Gravel Backfill Gravel Backfill Cover Frame 1" [25 mm] Thick Expansion Joint Material30" [762 mm] Riser #4 [13 mm] Rebar @ 6" [152 mm] Each Way 3,000 psi [20 MPa] (min) Concrete Manhole Frame & Cover Detail For Traffic Loading Areas NTS If traffic loading (H-20) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1-inch [25 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Backfill (90% Proctor Density) Vent Arched Baffles Slide riser over top ring and bolt in 4 places Riser Swirl Inlet/Outlet Grade (Rim) Rim elevations to match finished grade. PCS risers should NOT be field cut by Contractor. Manhole Frame and Cover by Manufacturer. (See Details) STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ Backfill shall extend at least 18 inches [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) Bedding Undisturbed Soil Backfill Section A-A Plan View Outlet A Vent Arched Baffles Octagonal Base Plate Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System A Inlet 18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK Rev. #Revision Description Issue Date 1 ADDENDUM 7/9/2019 3 ASI #1 8/28/2019 - STORM DETAILS Bollard Detail Document: Drawn By: Date: Scale: Concrete Rev. Date CAD Op. 12/10/02 NTS LZJ Description of Revision™ Phone (888) 344-9044 Fax (423) 870-1005 2733 Kanasita Drive, Suite B, Chattanooga, TN 37343 www.aquashieldinc.com STORMWATER TREATMENT SOLUTIONS Conc. Top To Be 1½" Thick At Center And Conc. Must Over Lap Edge of Pipe. 6" Dia. STL. Pipe fill w/Conc. Finish Grade 2 - #4 Bars, 1'-6" LG. 2' - 0" Dia. Conc. Encasement Swirl Unit OutSide Diameter Scale: Date: Drawn By: Document: STORMWATER TREATMENT SOLUTIONS www.aquashieldinc.com 2733 Kanasita Drive, Suite B, Chattanooga, TN 37343 Phone (888) 344-9044 Fax (423) 870-1005 Bollard Detail ™Description of RevisionRev. Date LZJ NTS 12/10/02 Concrete CAD Op. BOLLARD (TYP.) SEE ADJACENT DETAIL. C603 SCALE: NONE 24" min. CONCRETE COLLAR FOR CASTINGS WITHIN ASPH. 6" min. 14 SECTION A-A CONCRETE COLLAR ROUND CASTING CASTING SQUARE CASTING CONCRETE 24" min. WITHIN ASPHALT AREAS CONCRETE COLLAR CJCJ CONTROL JOINTS CJCJ NOTES: ALL INLET CASTINGS SHALL HAVE "NO DUMPING DRAINS TO STREAM" AND A FISH SYMBOL CAST INTO TOP OF CASTING. 1. 2 TAC COMMENTS 8/12/2019