HomeMy WebLinkAboutC604 - SITE DETAILS18095 Project Number: Drawing Number: Certified By: Checked ByDrawn ByIssue Date Revisions:PROJECT:Scope Drawings:CARMEL, INDIANANEWFORCARMEL CLAY SCHOOLSCARMEL ELEMENTARY SCHOOLSDrawing Title: 06-21-19 SO MK Rev. #Revision Description Issue Date 1 ADDENDUM 7/9/2019 3 ASI #1 8/28/2019 SITE DETAILS WATER DISTRIBUTION PLAN NOTES ALL WATER MAIN WORK SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY OF CARMEL INDIANA. CALL CARMEL UTILITIES FOR PRE CONSTRUCTION MEETING PRIOR TO BEGINNING WATER MAIN INSTILLATION. PRESSURE UTILITY MAINS AND SERVICE LINES MAY NEED TO BE INSTALLED AT A DEPTH GREATER THAN THAT SPECIFIED OR SHOWN ON THE DRAWINGS TO CLEAR EXISTING AND PROPOSED CROSSING UTILITIES. IN SUCH CASES, THE CONTRACTOR SHALL INSTALL VERTICAL BENDS AS REQUIRED TO ACHIEVE APPROPRIATE CLEARANCE BETWEEN THE CROSSING UTILITIES. A MINIMUM HORIZONTAL SEPARATION OF 10 FEET BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT ALL TIMES. A MINIMUM VERTICAL SEPARATION OF 18 INCHES BETWEEN WATER LINES AND SEWERS SHALL BE MAINTAINED AT CROSSINGS. IN THE EVENT THAT MINIMUM SEPARATION REQUIREMENTS CANNOT BE MET, THE CONTRACTOR SHALL UTILIZE PRESSURE-TYPE WATER PIPE FOR THE SEWER PER DETAIL 11 ON SHEET C606. WATER MAINS SHALL BE INSTALLED WITH A MINIMUM OF 54 INCHES OF COVER AS MEASURED FROM THE TOP OF THE PIPE TO THE FINAL FINISH GRADE ABOVE THE PIPE. JOINT RESTRAINTS SHALL BE INSTALLED ON ALL WATER LINES AT ALL BENDS, TEES AND HYDRANTS PER THE DETAILS OF THE WATER COMPANY. POSI-CAPS ARE REQUIRED ON ALL VALVES. WHERE GRADE MODIFICATIONS (CUT OR FILL) ARE SHOWN ADJACENT TO EXISTING VALVE BOX COVERS, THE VALVE BOX COVERS SHALL BE ADJUSTED FLUSH WITH THE PROPOSED GRADE. SERVICE LATERALS SHALL BE INSTALLED AT THE TIME OF MAIN CONSTRUCTION EXTENDING TO A DISTANCE OF 3 FEET FROM THE BUILDING. LOCATIONS OF EXISTING UNDERGROUND UTILITIES ARE APPROXIMATE. THE CONTRACTOR IS TO FIELD VERIFY ALL HORIZONTAL AND VERTICAL LOCATIONS PRIOR TO CONSTRUCTION. WATER LINES SHALL BE INSTALLED, DISINFECTED AND TESTED IN ACCORDANCE WITH THE CURRENT STANDARDS AND SPECIFICATIONS FOR INSTALLING WATER MAINS AND FIRE HYDRANTS AS ISSUED BY THE LOCAL GOVERNING AGENCY. PIPING SHALL BE LAID TO THE LINES AND GRADES OF 54 INCHES OF COVER OVER THE TOP OF THE PIPE BARREL TO FINISHED GRADE FOR 3-INCH, 6-INCH, AND 8-INCH PIPE AND 48 INCHES OF COVER OVER THE TOP OF THE PIPE FOR 12-INCH AND LARGER PIPE. PIPELINES OR RUNS INTENDED TO BE STRAIGHT SHALL BE LAID STRAIGHT. CURVES MAY BE FORMED BY USING FITTINGS OR BEVELED JOINTS. THE CONTRACTOR/DEVELOPER SHALL USE SURVEYING INSTRUMENTS TO MAINTAIN ALIGNMENT AND GRADE. THE CONTRACTOR SHALL BE BILLED FOR ALL BACTERIOLOGICAL LAB SERVICES. ALL VALVES, HYDRANTS, FITTINGS ETC. ARE REQUIRED TO BE CAPTURED USING GPS POINTS (SURVEY GRADE) AND SUBMITTED WITH AS-BUILTS. 7. 6. 4. 5. 3. 2. 1. 8. 9. ‚ 10. 11. 12. 4 SCALE: NONE WATER LINE CROSSING 7 WATER MAIN CONNECTION 8 9 PIPE TRENCH AND BEDDING DETAIL JOINT RESTRAINT TABLE 13. GATE VALVE AND BOX6SCALE: NONE 1-1/2" GRAVEL BACKFILL EXTENSION STEM VALVE BOX CENTERING RING EARTH UNDISTURBED GATE VALVE 2'-0" MIN5'-0" MAXCONCRETE BLOCKING COVER STAMPED "WATER" FINISHED GRADE 5 SCALE: NONE WATER NOTES 14. C604 CONCRETE ENCASEMENT DETAIL1SCALE: NONE FIRE HYDRANT ASSEMBLY2SCALE: NONE LIMITS OF SPECIAL BACKFILL3SCALE: NONE WA-16A FIRE DEPARTMENT CONNECTION DETAIL SCALE: NONE36"FINISH GRADE 5" STORZ CONNECTION 54" MIN.CONNECTION TO SPRINKLER SYSTEM. SIZE PER FIRE PROTECTION PLANS. CONCRETE THRUST BLOCK 4" DRAINAGE BED WASHED #8 STONE BALL DRIP 2 TAC COMMENTS 8/12/2019