Loading...
HomeMy WebLinkAboutC800 UTILITY PLANGGGT(U)T(U)T(U)T(U)T(U)E(U)T(U)T(U)T(U)T(U)E(U)E(U)T(U)T(U)T(U)T(U)T(U)E(U)E(U)E(U)E(U)E(U)E(U)E(U)T(U)T(U)T(U)T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U)T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U)T(U)T(U) T(U) T(U) T(U) T(U) T(U)T(U) T(U)T(U)T(U)T(U)T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U)T(U)T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U) E(U)GGGGGGGGGGG G G G G G G G G G G G G G SPRING RUN ESTATESCROOKED STICK SECTION 5C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C E E E E E E E E E E E E E E E E E E E EEEEEEEEEEEEEPROPOSED MAINT. BLDG. 5000 SF F.F.E. 869.0 MFPG=869± MLAG=869.0 PROPOSED ADMIN. BLDG. 3600 SF F.F.E. 874.8 MFPG=866± MLAG=874.75 STAIR WELL & STORAGE 413 SF F.F.E. 874.8 MFPG=866± MLAG=874.80 EEEECCCCCFMFMFMFMFM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FM FMWWWW W WWWW W W WW SANSANSANSANSANEEEEGGGT(U)T(U)T(U)T(U)T(U)EET(U)T(U)T(U)T(U)EET(U)T(U)T(U)T(U)T(U)EEEEEEE ET(U)T(U)T(U)T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U)T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U)T(U)T(U) T(U) T(U) T(U) T(U) T(U)T(U) T(U)T(U)T(U)T(U)T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U)T(U)T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) T(U) E E E E E E E E E E E E E E E E E E E E E E GGGGGGGGGGG G G G G G G G G G G G G G SPRING RUN ESTATES SPRING RUN ESTATESCROOKED STICK SECTION 5WWW W W W W W W W W W W W W W W W W W W W W W W W W W W GENERAL UTILITY NOTES 1.THE CONTRACTOR SHALL CONTACT APPLICABLE STATE UNDERGROUND LOCATION SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK AND SHALL CONTACT THE OWNER AND/OR ENGINEER SHOULD UTILITIES APPEAR TO BE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 2.THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED WITHIN THE LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY OF THIS INFORMATION IS NOT GUARANTEED. 3.THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS, CONDUITS, SERVICE LINES, ETC. WITHIN THE CONSTRUCTION LIMITS. THE LOCATION AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY COMPANY) IS THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR. 4.THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND VERIFY ANY AND ALL FEES ASSOCIATED WITH THE INSTALLATION OF ALL UTILITIES. 5.ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A. STANDARDS FOR WORKER SAFETY. 6.ANY PART OF SANITARY OR STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL. 7.IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY LOCATION, SIZE, AND ELEVATION OF EXISTING UTILITIES, STRUCTURES, PIPES, PAVEMENTS, ETC. AS RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS. 8.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL CLEARANCE BETWEEN STORM / SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE. SANITARY SEWER LINE IN PROXIMITY OF WATER LINE SHALL BE C900 WATER MAIN GRADE PVC. 9.CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION (AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWERS, WATER MAINS AND STORM SEWERS IS 18" OR LESS. 10.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR BETTER. 11.WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO CONTROL MOISTURE OF SOILS. 12.COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS. 13.ALL UTILITY STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND SHALL HAVE TRAFFIC BEARING RING AND COVERS. 14.PROVIDE THRUST BLOCKS FOR ALL WATER LINE BENDS AND TEES, INCLUDING TAP CONNECTION. 15.CONTRACTOR SHALL COORDINATE WITH WATER COMPANY FOR DOMESTIC AND FIRE SERVICE. CONNECT TO BUILDING DOMESTIC AND FIRE LINE. COORDINATE WITH PLUMBING DRAWINGS. 16.COORDINATE LOCATION OF ELECTRICAL AND COMMUNICATION LINES WITH LOCAL UTILITIES. 17.COORDINATE LOCATION OF REQUIRED CONDUITS FOR ELECTRIC SERVICE, LIGHT POLES, COMMUNICATION SERVICE AND IRRIGATION SYSTEM. 18.COORDINATE LOCATION AND SIZE OF GAS SERVICE CONNECTION AND INSTALLATION OF SERVICE LINE AND METER WITH GAS COMPANY. 19.COORDINATE LOCATIONS AND CONNECTIONS OF BUILDING STORM LINES WITH PLUMBING DRAWINGS. 20.FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO DOMESTIC/FIRE LINE INSTALLATION AND STORM SEWER / SANITARY SEWER INSTALLATION. 21.SANITARY SEWER LATERAL, WATER SERVICE, & ELECTRICAL/COMMUNICATION CONDUITS SHALL BE GRANULAR BACKFILL FOR ENTIRE RUN. 22.ALL EXISTING MANHOLE AND CATCH BASIN GRATES, WATER OR GAS VALVES SHALL BE ADJUSTED TO NEW FINISH GRADE ELEVATIONS. UTILITY PLAN NOTES SANITARY SEWER NOTES DIRECTIONAL BORE 45 L.F. OF 1.25" HDPE SDR-11 SANITARY SEWER FORCE MAIN WITH TWO (2) #8 TRACER WIRES, REFER TO SHEET C500. PROPOSED 72 L.F. OF 6" PVC SDR-35 SANITARY SEWER LATERAL AT S = 9.00%. VERIFY BUILDING LOCATION AND INVERT DEPTH WITH PLUMBING PLANS, REFER TO TRENCH DETAIL ON SHEET C801. PROPOSED SANITARY SEWER GRINDER STATION, REFER TO DETAIL ON SHEET C501. PROPOSED TYPE 1 SANITARY SEWER LATERAL CLEANOUT, REFER TO DETAIL ON SHEET C501. FORCE MAIN LATERAL ASSEMBLY, REFER TO DETAIL ON SHEET C501 INTERIOR GREASE INTERCEPTOR, REFER TO PLUMBING PLANS. PROVIDE 18" MINIMUM VERTICAL CLEARANCE BETWEEN UTILITIES WHEN POSSIBLE. INSTALL CONCRETE CRADLE IF CLEARANCE IS LESS THAN 18" TRACER STATION, REFER TO SHEET C501 WATER SERVICE NOTES: COORDINATE AND CONNECT 2" WATER SERVICE LINE. REUSE VACANT METER PIT. COORDINATE CONNECTION OF DOMESTIC SERVICE LINE WITH PLUMBING DRAWINGS. COORDINATE CONNECTION OF DOMESTIC METER LOCATION WITH LOCAL SERVICE PROVIDER. EXISTING FIRE HYDRANT. PROPOSED 2" PE DOMESTIC SERVICE LINE ELECTRIC NOTES: COORDINATE AND CONNECT BUILDING ELECTRICAL LINE FROM SERVICE DROP LOCATION TO TRANSFORMER. COORDINATE CONNECTION WITH POWER COMPANY AND ELECTRICAL DRAWINGS. ADJUST AS REQUIRED. 2-4" EC CONDUITS TO BE INSTALLED WITH PULL STRINGS. EXISTING TRANSFORMER PAD LOCATION. COORDINATE WITH UTILITY PROVIDER IF A NEW TRANSFORMER IS REQUIRED. BUILDING ELECTRICAL LINE POINT OF CONNECTION. COORDINATE CONNECTION WITH POWER COMPANY AND ELECTRICAL DRAWINGS. ADJUST AS REQUIRED. FURNISH AND INSTALL CONDUIT AND ELECTRICAL SERVICE LINE TO SANITARY SEWER PUMPING STATION. GRINDER PUMP ELECTRICAL SERVICE REQUIRES 230v, 1 PHASE POWER. COMMUNICATION NOTES: COORDINATE AND CONNECT BUILDING COMMUNICATION SERVICE LINE(S) TO CONNECTION POINT AS SHOWN. ADJUST AS REQUIRED. 4" PVC CONDUIT TO BE INSTALLED WITH PULL STRINGS. GAS SERVICE NOTES: GAS SERVICE IS LOCATED ALONG THE SOUTH SIDE OF CROOKED STICK LANE. CALL THE NEW SERVICE CENTER PHONE # 1-800-990-1930 TO COORDINATE SERVICE WITH VECTREN. W4 W2 W3 SS3 SS2 W1 SS4 E1 E2 C1 G1 SS5 SS1 SS6 W5 SS7 C800UTILITY PLANELECTRICAL RISER GUY ANCHOR ELECTRIC JUNCTION BOX ORNAMENTAL LIGHT GENERATOR STREET LIGHT ELECTRIC MANHOLE UTILITY POLE UTILITY POLE W/ TRANSFORMER TRANSFORMER COMMUNICATIONS JUNCTION BOX COMMUNICATIONS MANHOLE COMMUNICATIONS PEDESTAL RIGHT OF WAY LINE FENCE GUARD RAIL BOUNDARY LINE FIRE DEPT HOOKUP FIRE HYDRANT POST INDICATOR VALVE WATER MANHOLE SPRINKLER CONTROL BOX SPRINKLER CONTROL VALVE SPIGOT WELL HEAD WATER METER WATER VALVE GAS METER GAS VALVE ELECTRIC METER LIQUID PROPANE GAS TANK MONITORING WELL BOLLARD FLAG POLE POST SIGN DOWN SPOUT COMMUNICATIONS RISER STORM CLEANOUT BEEHIVE INLET CURB INLET ROUND INLET SQUARE INLET STORM MANHOLE SANITARY SEWER CLEANOUT LIFT STATION SANITARY SEWER MANHOLE SANITARY STUB MARKER PARKING LOT LIGHT (1 HEAD) ROW RIGHT OF WAY ESMT EASEMENT D.&U.E.DRAINAGE AND UTILITY EASEMENT FFE FINISH FLOOR ELEVATION TOC TOP OF CASTING CMP CORRUGATED METAL PIPE RCP REINFORCED CONCRETE PIPE PVC POLYVINYL CHLORIDE PIPE VCP VITRIFIED CLAY PIPE HDPE HIGH DENSITY POLYETHYLENE PIPE DIP DUCTILE IRON PIPE SSD SUB SURFACE DRAIN PIPE STM STORM SAN SANITARY STR STRUCTURE CO CLEANOUT UTILITY PLAN LEGEND UTILITIES ABBREVIATIONS OTHER LINE TYPES FLOW LINE SANITARY SEWER MAIN STORM SEWER MAIN UNDERGROUND GAS UNDERGROUND WATER AERIAL ELECTRIC UNDERGROUND ELECTRIC UNDERGROUND COMM. AERIAL COMMUNICATIONS OVERHEAD UTILITY FORCE MAIN G G G W W E(A)E(A) E E E C C C C(A)C(A) OHU OHU FM FM AERIAL FIBER OPTIC CABLEFO(A)FO(A) UNDERGROUND FIBER OPTICFOFO SANITARY SEWER LATERALSANSAN ROOF DRAINSTMSTM SUB SURFACE DRAIN E3 REVISIONS AND ISSUESW17.0206PREPARED FOR:11128 CROOKED STICK LANE, CARMEL, IN 46032PROJECT NO. SHEET NO.CHECKED BY:DRAWN BY:RAMDESIGNED BY:DWG NAME:PROJECT NO.:W17.0206DATEBY12.20.2017BJSDATE:RAMKnow what's below. before you dig.Call R MAINTENANCE BUILDINGISSUED FOR CARMEL TAC11.09.2017BJSISSUED FOR STATE RELEASE11.27.2017BJSW S N E STEVEN SCOTT RUCKER P.E. 11300279ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SM12/20/2017 Part of the NW/4 of Section 14, Township 16 North, Range 4 East, Hamilton County, IndianaCTRWD SANITARY PERMIT APPLICATION11.21.2017WACISSUED FOR DRAINAGE REVISIONS12.08.2017BJSISSUED FOR DRAINAGE REVISIONS12.13.2017BJSISSUED FOR FINAL CONSTRUCTION DRAWINGS12.20.2017BJSE4 SS8