HomeMy WebLinkAboutC602 OVERFLOW ROUTING PLANE
OHUOHUOHUOHU OHU OHU OHU OHU
OHU
OHU
OHU
OHU
OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU OHU
G
W
W
W
G
G
W
WEST CAR
M
E
L
D
R
I
V
E
GGG
PROPOSED BUILDING
20,121SF± PER FLOOR
F.F.E. = 829.85CEEEEESTMSTMSTMSTMSTMSTMSTM
STMSTMSTMSTMSTMSTMESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
ESMT. FOR BMP,
DETENTION, AND ACCESS
DRY POND WWWWWWWWWWWWWWWWWWWC602OVERFLOW ROUTING PLANW190582-C601 OVERFLOW ROUTING PLANREVISIONS AND ISSUESPart of Section 36, Township 18 North, Range 3 East, Hamilton County, IndianaW19.0582PREPARED FOR:147 & 155 WEST CARMEL DRIVE, CARMEL, INDIANAPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:SSRDESIGNED BY:DWG NAME:PROJECT NO.:W19.0582DATEBY03.30.2020SSRDATE:SSRKnow what's below.
before you dig.Call
R APPROVAL PENDINGNOT FOR CONSTRUCTIONCARMEL SELF STORAGEISSUED FOR CITY REVIEW01.13.2020BJSW
S
N
E ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMSTEVEN SCOTT RUCKER, PE No. 11300279
03/30/2020TAC REVISIONS03.30.2020BJSELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
BOLLARD
POST
SIGN
PARKING WHEEL STOP
DOWN SPOUT
ACCESSIBLE SPACE
GATE POST
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
PARKING LOT LIGHT (1 HEAD)
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E.DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
TOC TOP OF CASTING
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
DRAINAGE PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
FLOW LINE
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E(A)E(A)
E E E
C C C
C(A)C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A)FO(A)
UNDERGROUND FIBER OPTICFOFO
EMERGENCY FLOOD ROUTE
SANITARY SEWER LATERALSANSAN
ROOF DRAINSTMSTM
SUB SURFACE DRAIN
FLOW DIRECTION AND SLOPE
D D LIMITS OF DISTURBANCE
GENERAL NOTES
THE SITE DOES NOT LIE IN A SPECIAL FLOOD HAZARD
AREA AS ESTABLISHED BY THE FEDERAL
EMERGENCY MANAGEMENT AGENCY - NATIONAL
FLOOD INSURANCE PROGRAM, WHEN PLOTTED BY
SCALE ON FLOOD INSURANCE RATE MAP
#18057C0209 G, DATED NOVEMBER 19, 2014.
BENCHMARK DATA
BM G 54 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5 FT. OUT OF THE GROUND ALONG
U.S. 31, 1.4 MILES NORTH OF I-465, 0.4 MILES SOUTH OF 116TH STREET, 100 FT. WEST OF
CENTERLINE OF SOUTH BOUND LANE OF U.S. 31, AND 2 FT. EAST OF R/W FENCE.
BM G 55 -
ISHC BRONZE DISK ON A CONCRETE POST PROJECTING 1.5 FT. OUT OF THE GROUND ALONG
U.S. 31, 2.6 MILES NORTH OF I-465, 0.7 MILES SOUTH OF 131ST STREET, 83 FT. WEST OF
CENTERLINE OF SOUTH BOUND LANE OF U.S. 31.
BM Y 42 -
CGS DISK IN CONCRETE SLAB ON THE EAST SIDE OF THE MONON TRAIL 218 FT. SOUTH OF 111TH
STREET.
M.F.P.G. = 828.40
M.L.A.G. = 828.55