HomeMy WebLinkAboutW3010002 CDSet 20190325ONEWAYW:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C001 - COVER SHEET.DWG - Last printed 3/25/2019 1:39 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
TITLE SHEETC001 SITEDEVELOPMENT PLANSFORHOME2 SUITESOLD MERIDIAN STREET, CARMEL,HAMILTON COUNTY, INDIANA 46032DEVELOPERENGINEERARCHITECTVACINITY MAPINDEX MAPSHEET INDEXSITE SUMMARYAPPROVAL PENDING - NOT FOR CONSTRUCTIONSITELOCATION MAPDOCKET NO. 17110016JURISDICTIONLEGAL DESCRIPTIONBENCHMARKSFLOOD PLAIN DATATOPOGRAPHIC NOTE
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C002 - GENERAL NOTES.dwg - Last printed 3/25/2019 1:40 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
GENERAL NOTESC002
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C100 - EX COND AND DEMO PLAN.dwg - Last printed 3/25/2019 1:40 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
EXISTING
CONDITIONS AND
DEMOLITION PLANC100 ABBREVIATIONSLEGEND KEYED NOTESBENCHMARKSFLOOD PLAIN DATATOPOGRAPHIC NOTEDEMOLITION NOTES
ONEWAYW:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C200 - SITE PLAN.dwg - Last printed 3/25/2019 1:40 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019ABBREVIATIONSLEGEND SITE PLAN NOTESNOTESSITE PLANC200 KEYED NOTESHANDICAP PARKING LAYOUT PLAN "D"EV CHARGER DETAILHANDICAP PARKING LAYOUT PLAN "C"
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C300 - UTILITY PLAN.DWG - Last printed 3/25/2019 1:40 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
UTILITY PLANC300 UTILITY PLAN NOTESKEYED NOTESABBREVIATIONSLEGEND BENCHMARKSTOPOGRAPHIC NOTE
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C400 - OVERALL DRAINAGE PLAN.DWG - Last printed 3/25/2019 1:41 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
OVERALL
DRAINAGE PLANC400 ABBREVIATIONSDRAINAGE SUMMARYLEGEND FLOOD PROTECTIONFLOOD PLAIN DATARETAINING WALL GRADING DETAILINDOT MINIMUM RIPRAP APRONDIMENSIONS
ONEWAYEX VFW BUILDINGW:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C401 - GRADING PLAN.dwg - Last printed 3/25/2019 1:41 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
GRADING PLANC401 GRADING NOTESABBREVIATIONSKEYED NOTESLEGEND KEYED NOTESVFW ADA GRADING DETAILDETENTION BASIN & BIOSWALE DETAIL, SECTION A-ARAIN GARDEN DETAILEMERGENCY SPILLWAY DETAIL, SECTION B-BBENCHMARKSTOPOGRAPHIC NOTESECTION B1-B1
ONE
WAY
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C401 - GRADING PLAN.dwg - Last printed 3/25/2019 1:41 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019C402BUILDING
GRADING DETAIL GRADING NOTESABBREVIATIONSLEGEND KEYED NOTES
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C403 - PROFILES.DWG - Last printed 3/25/2019 1:41 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
STORM SEWER
PROFILESC403 BENCHMARKSTOPOGRAPHIC NOTE
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C404 - WATER QUALITY.DWG - Last printed 3/25/2019 1:41 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
WATER QUALITY
DETAILSC404
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C405 - UNDERGROUND DET.DWG - Last printed 3/25/2019 1:41 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
UNDERGROUND
DETENTION
DETAILSC405 24"851.052,262 CF7,892 CFBOTTOM OF PIPEELEV. = 851.05TOP OF PIPEELEV. = 855.0510-YEAR PONDINGELEV. = 853.02100-YEAR PONDINGELEV. = 854.24BOTTOM OF PAVEMENTMINIMUM ELEV. = 856.12BOTTOM OF BEDDING/EXCAVATION LIMITELEV. = 850.55
ONEWAYW:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C500 - SWPPP.DWG - Last printed 3/25/2019 1:42 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
STORMWATER
POLLUTION
PREVENTION PLANC500SOILS MAPBrCrABrCrACrALEGENDKEYED NOTES
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C501 - SWPPP NOTES.DWG - Last printed 3/25/2019 1:42 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
SWPPP NOTESC501 PERMANENT SEEDINGTEMPORARY SEEDINGEROSION CONTROL MONITORING & MAINTENANCE GUIDELINESEROSION CONTROL MEASUREMONITORING & MAINTENANCE
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C501 - SWPPP NOTES.DWG - Last printed 3/25/2019 1:42 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019CONCRETE WASHOUT AREATHE DANDY BAGPROFILEPLAN VIEWSTABILIZED CONSTRUCTION ENTRANCESILT FENCE:SEDIMENT FENCE BARRIER DETAILPLAN VIEWSECTION B-BCONCRETE WASHOUTSIGN DETAILCONCRETEWASHOUTSTAPLE DETAILPLAN VIEWPLAN VIEWSECTION B-BSECTION A-ATYPE "BELOW GRADE"TYPE "ABOVE GROUND"WITH WOOD PLANKSTYPE "ABOVE GROUND"WITH STRAW BALESNOTESSWPPP DETAILSC502RAIN GARDEN TYPICAL CROSS SECTIONRAIN GARDEN TYPICAL PLAN VIEWRAIN GARDEN PROTECTION SIGNDETENTION PROTECTION SIGN
SLOPEINSTALLATIONDETAILDrawing Not To Scale1.Prepare soil before installing rollederosion control products (RECPs),including any necessaryapplication of lime, fertilizer, andseed.2.Begin at the top of the slope byanchoring the RECPs in a6"(15cm) deep X 6"(15cm) widetrench with approximately 12"(30cm) of RECPs extended beyondthe up-slope portion of the trench.Anchor the RECPs with a row ofstaples/stakes approximately 12"(30cm) apart in the bottom of thetrench. Backfill and compact thetrench after stapling. Apply seed tothe compacted soil and fold theremaining 12"(30cm) portion ofRECPs back over the seed andcompacted soil. Secure RECPsover compacted soil with a rowof staples/stakes spacedapproximately 12"(30cm) apartacross the width of the RECPs.3.Roll the RECPs (A) down or (B)horizontally across the slope.RECPs will unroll with appropriateside against the soil surface. AllRECPs must be securely fastenedto soil surface by placingstaples/stakes in appropriatelocations as shown in the staplepattern guide.4.The edges of parallel RECPs mustbe stapled with approximately 2" -5" (5-12.5cm) overlap dependingon the RECPs type.5.Consecutive RECPs spliced downthe slope must be end over end(Shingle style) with an approximate3"(7.5cm) overlap. Staple throughoverlapped area, approximately12"(30cm) apart across entireRECPs width.Drawn on: 5-4-17Disclaimer:The information presented herein is general design information only. For specific applications,consult an independent professional for further design guidance.2"-5"(5-12.5cm)3B42513A12"(30cm)6"(15cm)6"(15cm) *NOTE:In loose soil conditions, the use ofstaple or stake lengths greater than6"(15cm) may be necessary toproperly secure the RECP's.3"(7.5cm)5401 St. Wendel - Cynthiana Rd.Poseyville, IN 47633PH: 800-772-2040www.nagreen.comW:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C501 - SWPPP NOTES.DWG - Last printed 3/25/2019 1:42 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
SWPPP DETAILSC503BELOW GRATE INLET PROTECTION
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C600 - DETAILS.dwg - Last printed 3/25/2019 1:43 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
SITE DETAILSC600 CONCRETE PAVEMENT SECTIONCONTRACTION JOINTSLAB ON GRADE TYPICAL CONSTRUCTION JOINTISOLATION JOINTHEAVY DUTY ASPHALT PAVEMENT SECTIONCONCRETE LIGHT BASE DETAIL6" BOLLARD6" BARRIER CURBSTANDARD COMBINED CURB & WALKASPHALT PAVEMENTMILL & OVERLAY SECTIONLIGHT DUTY ASPHALT PAVEMENT SECTIONROCK CHECK DAMCONCRETE CURB TURNOUT
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C600 - DETAILS.dwg - Last printed 3/25/2019 1:43 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
SITE DETAILSC601 βCONCEPTUAL GEOGRID REINFORCED MODULAR BLOCKRETAINING WALL DETAILSTANDARD HANDICAP PARKING SIGNTYPICAL SIDEWALK SECTIONPARKING BLOCK DETAILCURB RAMP DETAIL "A"TYPICAL FENCE ASSEMBLYCURB RAMP DETAIL "B"CONCRETE PAVER SECTION
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C600 - DETAILS.dwg - Last printed 3/25/2019 1:43 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
SITE DETAILSC602PRECAST CONCRETE END SECTIONOUTLET CONTROL STRUCTURE 1TRENCH BACKFILL DETAILKEYED NOTESSOUTH UTILITY ENTRANCE DETAIL
ONEWAYW:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - C700 - ILLUMINATION.dwg - Last printed 3/25/2019 1:43 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019ABBREVIATIONSLEGEND ILLUMINATION PLANC700ILLUMINATION PLAN NOTES
ONEWAYW:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - L100 - LANDSCAPE PLAN.dwg - Last printed 3/25/2019 1:43 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
LANSCAPE PLANL100 ABBREVIATIONSLEGEND LANDSCAPE PLANT LISTNOTESLANDSCAPE IRRIGATION SYSTEM
ONE
WAY
W:\Projects\Projects U-Z\W3010002\CAD\SITE PLANS\W3010002 - L100 - LANDSCAPE PLAN.dwg - Last printed 3/25/2019 1:43 PM
CHECKED BY:
DRAWN BY:
PROJECT NO.:
PROJECT DATE:
RJT
PMV
W3010002
3/7/2019
1160 DUBLIN ROAD
SUITE 100
COLUMBUS, OH 43215
TEL: 614.441.4222
FAX: 888.488.7340
PREPARED FOR:
600 ENTERPRISE DRIVE
LEWIS CENTER, OHIO 43035
WITNESS CARMEL LLC
SITE CONSTRUCTION DRAWINGS
FOR
HOME2 SUITES
BY HILTON
12845 OLD MERIDIAN STREET
CARMEL, INDIANA 46032
NO.DATE BY DESCRIPTION
1 01-04-2018 PMV CITY COMMENTS
2 01-25-2018 RJT CITY COMMENTS
3 07-04-2018 RJT CITY COMMENTS
4 11-09-2018 RJT PERMIT SET
5 2-05-2019 RJT CITY COMMENTS
6 3-07-2019 RJT CITY AND STATE SUBMITTAL
5 RJT CITY COMMENTS3-21-2019
LANDSCAPE
DETAILSL101 BUILDING LANDSCAPE DETAILTYPICAL ISLAND MULCHING DETAILLANDSCAPE PLANTING NOTESNOTES