HomeMy WebLinkAboutC600 DRAINAGE PLANSTM
STMST
M
WWWWWWWWWWWWWWWWCCCCCCCCCCCCCCGGGW
W
W
W
W
W
W
WPROPOSED BU
ILD
INGGFA=31,808
SFFFF=889.40M.F
.P
.G
.=887
.13M.L
.A
.G
.=888
.40
11
14
23
23
8
14
9
3
5
8
4
10
CCCCCCCCCCCCEEW
W
W
W
WSTMSTM
STM
STMSTMSTMSTMSTMSTM
STM
STM
STM
POND
N.P. = 883.00
100 YR. = 887.13
T.O.B. = 887.13
POND
N.P. = 879.00
100 YR. = 883.67
T.O.B. = 888.67
D DDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDDD D
D DD
DDDD
D
D
D
D
D DDDD DDDDDEEEEEEEE1
1
1
1
1
1
1
1
1
1
1
1
3
3
4
5
5
5
5
5
5
6
8
7
7
2
2
2
2
2
2
4
9
100 YEAR
CLOGGED
INLET
SPREAD
ELEV=887.5
100 YEAR
CLOGGED
INLET
SPREAD
ELEV=887.3
100 YEAR
CLOGGED
INLET
SPREAD
ELEV=887.3
100 YEAR
CLOGGED
INLET
SPREAD
ELEV=887.5
4
STORM SEWER STRUCTURE DATA TABLE
STRUCTURE NUMBER
201
202
203
204
205
206
207
STRUCTURE TYPE
???
MANHOLE
MANHOLE
MANHOLE
MANHOLE
MANHOLE
INLET TYPE J
TOP OF CASTING
880.79
888.62
886.84
886.89
886.65
888.88
886.82
CASTING TYPE
???
NEENAH R-1642
NEENAH R-3405
NEENAH R-3405
NEENAH R-3287
NEENAH R-1642
NEENAH R-3287-10V
INVERT
INV IN = 879.00(NW)
INV IN = 880.00(NW)
INV OUT = 879.90(SE)
INV IN = 880.34(NW)
INV OUT = 880.24(SE)
INV IN = 880.76(NW)
INV OUT = 880.66(SE)
INV IN = 881.03(NE)
INV OUT = 880.93(SE)
INV IN = 882.88(NE)
INV OUT = 881.25(SW)
INV OUT = 883.22(SW)
DETAIL LOCATION
SEE CONCRETE END
SECTION DETAIL ON C602
SEE STANDARD STORM
MANHOLE DETAIL ON
C602
SEE STANDARD STORM
MANHOLE DETAIL ON
C602
SEE STANDARD STORM
MANHOLE DETAIL ON
C602
SEE STANDARD STORM
MANHOLE DETAIL ON
C602
SEE INLET TYPE J DETAIL
ON C602
SEE STANDARD STORM
MANHOLE DETAIL ON
C602
END SECTION END SECTIONN/A
STORM SEWER PIPE DATA TABLE
UPSTREAM
STRUCTURE
202
203
204
205
206
207
DOWNSTREAM
STRUCTURE
201
202
203
204
205
206
SIZE
18"
36"
36"
36"
36"
12"
MATERIAL
RCP
RCP
RCP
RCP
RCP
RCP
LENGTH
61'
97'
126'
70'
89'
93'
SLOPE
1.47%
0.25%
0.25%
0.25%
0.25%
0.37%
DRAINAGE PLAN NOTES
DOWNSPOUT/ROOF DRAIN POINT OF CONNNECTION. COORDINATE WITH ARCHITECTURAL PLANS.
6" HDPE DUAL WALLED HANCOR HQ OR EQUIVALENT ROOF DRAIN @ 1.0% MINIMUM
8" HDPE DUAL WALLED HANCOR HQ OR EQUIVALENT ROOF DRAIN @ 1.0% MINIMUM
10" HDPE DUAL WALLED HANCOR HQ OR EQUIVALENT ROOF DRAIN @ 1.0% MINIMUM
4" SUBSURFACE DRAINS, PERFORATED DUAL WALLED HANCOR HQ OR EQUIVALENT
WATER QUALITY UNIT, REFER TO SHEET C602 FOR MAKE AND MODEL
VEGETATED FILTER STRIP WITH LEVEL SPEADER. REFER TO DETAIL ON SHEET C602
BYPASS STRUCTURE. WEIR HEIGHT=880.33'
CONTRACTOR TO VERIFY IF THERE IS SSD UNDER EXISTING CURB AT ENTRANCE. SSD TO CONTINUE IF EXISTING UNDER
NEW DEPRESSED CURB.
C600DRAINAGE PLANw180330-C600 drainage plan1
2
3
4
5
6
7
ELECTRICAL RISER
GUY ANCHOR
ELECTRIC JUNCTION BOX
ORNAMENTAL LIGHT
GENERATOR
STREET LIGHT
ELECTRIC MANHOLE
ELECTRIC OUTLET
UTILITY POLE
UTILITY POLE W/ TRANSFORMER
TRANSFORMER
COMMUNICATIONS JUNCTION BOX
COMMUNICATIONS MANHOLE
COMMUNICATIONS PEDESTAL
RIGHT OF WAY LINE
FENCE
GUARD RAIL
BOUNDARY LINE
FIRE DEPT HOOKUP
FIRE HYDRANT
POST INDICATOR VALVE
CHILLED WATER MANHOLE
WATER MANHOLE
SPRINKLER CONTROL BOX
SPRINKLER CONTROL VALVE
SPRINKLER
SPIGOT
WELL HEAD
WATER METER
WATER VALVE
GAS METER
GAS VALVE
ELECTRIC METER
LIQUID PROPANE GAS TANK
MONITORING WELL
TRAFFIC SIGNAL POLE
TRAFFIC SIGNAL
DOWN SPOUT
COMMUNICATIONS RISER
STORM CLEANOUT
BEEHIVE INLET
CURB INLET
FLOOR DRAIN
ROUND INLET
SQUARE INLET
STORM MANHOLE
SANITARY SEWER CLEANOUT
LIFT STATION
SANITARY SEWER MANHOLE
SANITARY STUB MARKER
PARKING LOT LIGHT (1 HEAD)
ROW RIGHT OF WAY
ESMT EASEMENT
D.&U.E.DRAINAGE AND UTILITY EASEMENT
FFE FINISH FLOOR ELEVATION
TOC TOP OF CASTING
CMP CORRUGATED METAL PIPE
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
VCP VITRIFIED CLAY PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE
DIP DUCTILE IRON PIPE
SSD SUB SURFACE DRAIN PIPE
STM STORM
SAN SANITARY
STR STRUCTURE
CO CLEANOUT
DRAINAGE PLAN LEGEND
UTILITIES
ABBREVIATIONS
OTHER
LINE TYPES
FLOW LINE
INDEX CONTOUR
INTERMEDIATE CONTOUR
SANITARY SEWER MAIN
STORM SEWER MAIN
UNDERGROUND GAS
UNDERGROUND WATER
AERIAL ELECTRIC
UNDERGROUND ELECTRIC
UNDERGROUND COMMUNICATIONS
AERIAL COMMUNICATIONS
OVERHEAD UTILITY
FORCE MAIN
G G G
W W
E(A)E(A)
E E E
C C C
C(A)C(A)
OHU OHU
FM FM
AERIAL FIBER OPTIC CABLEFO(A)FO(A)
UNDERGROUND FIBER OPTICFOFO
EMERGENCY FLOOD ROUTE
SANITARY SEWER LATERALSANSAN
ROOF DRAINSTMSTM
SUB SURFACE DRAINFLOW DIRECTION AND SLOPE
GENERAL DRAINAGE NOTES
1.THE CONTRACTOR SHALL ADHERE TO ALL TERMS AND CONDITIONS AS OUTLINED IN
THE EPA OR APPLICABLE STATE GENERAL N.P.D.E.S. PERMIT FOR STORMWATER
DISCHARGE ASSOCIATED WITH CONSTRUCTION ACTIVITIES AND STORMWATER
POLLUTION PREVENTION PLAN.
2.REFER TO THE INDIANA DEPARTMENT OF TRANSPORTATION (INDOT) STANDARD
SPECIFICATIONS, LATEST EDITION, FOR BASIC MATERIALS AND CONSTRUCTION
METHODS. THE SECTIONS BELOW FOR VARIOUS ITEMS ARE TO CLARIFY THE INTENT
OF THE REQUIREMENTS FOR THIS PROJECT. PLEASE NOTE THAT OTHER SECTIONS
OF THE INDOT STANDARD SPECIFICATIONS MAY ALSO BE APPLICABLE.
3.THE CONTRACTOR SHALL CONTACT APPLICABLE STATE UNDERGROUND LOCATION
SERVICE AT LEAST 72 HOURS PRIOR TO ANY WORK AND SHALL CONTACT THE OWNER
AND/OR ENGINEER SHOULD UTILITIES APPEAR TO BE IN CONFLICT WITH THE
PROPOSED IMPROVEMENTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR
TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED
IMPROVEMENTS SHOWN ON THE PLANS.
4.THE PLANS SHOW THE LOCATION OF ALL KNOWN UTILITIES LOCATED WITHIN THE
LIMITS OF CONSTRUCTION ACCORDING TO INFORMATION PROVIDED BY THE VARIOUS
UTILITY COMPANIES, PREVIOUS CONSTRUCTION PLANS AND AS EVIDENCED BY
OBSERVATION OF ABOVE GROUND CONDITIONS BY THE SURVEYOR. THE ACCURACY
OF THIS INFORMATION IS NOT GUARANTEED.
5.THE CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES TO LOCATE MAINS,
CONDUITS, SERVICE LINES, ETC. WITHIN THE CONSTRUCTION LIMITS. THE LOCATION
AND PROTECTION OF UTILITY STRUCTURES, THEIR SUPPORT AND MAINTENANCE
DURING CONSTRUCTION (IN COOPERATION WITH APPLICABLE UTILITY COMPANY) IS
THE EXPRESSED RESPONSIBILITY OF THE CONTRACTOR.
6.THE CONTRACTOR SHALL CONTACT ALL APPLICABLE UTILITIES AND VERIFY ANY AND
ALL FEES ASSOCIATED WITH THE INSTALLATION OF ALL UTILITIES.
7.ALL CONSTRUCTION ON THIS SITE TO BE PERFORMED IN COMPLIANCE WITH O.S.H.A.
STANDARDS FOR WORKER SAFETY.
8.ANY PART OF STORM SEWER TRENCHES RUNNING UNDER OR WITHIN 5' OF
PAVEMENT TO BE BACKFILLED WITH GRANULAR MATERIAL.
9.IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY LOCATION, SIZE, AND
ELEVATION OF EXISTING UTILITIES, STRUCTURES, PIPES, PAVEMENTS, ETC. AS
RELATED TO THEIR WORK. NOTIFY ENGINEER OF ANY CONFLICT AND/OR
DISCREPANCIES IN THE CONSTRUCTION DOCUMENTS.
10.MAINTAIN 10' HORIZONTAL AND 18" VERTICAL CLEARANCE BETWEEN STORM /
SANITARY SEWER SYSTEMS AND DOMESTIC/FIRE LINE SERVICE. SANITARY SEWER
LINE IN PROXIMITY OF WATER LINE SHALL BE C900 WATER MAIN GRADE PVC.
11.CONTRACTOR TO INSTALL CONCRETE CRADLES WHEN THE VERTICAL SEPARATION
(AS MEASURED FROM THE EXTERIOR OF THE PIPES) BETWEEN SANITARY SEWERS,
WATER MAINS AND STORM SEWERS IS 24" OR LESS.
12.IF ANY EXISTING STRUCTURES TO REMAIN ARE DAMAGED DURING CONSTRUCTION, IT
SHALL BE THE CONTRACTORS RESPONSIBILITY TO REPAIR AND/OR REPLACE THE
EXISTING STRUCTURE AS NECESSARY TO RETURN IT TO EXISTING CONDITIONS OR
BETTER.
13.WHEN PERFORMING EXCAVATIONS DURING PERIODS OF WET WEATHER, PROVIDE
ADEQUATE DEWATERING, DRAINAGE AND GROUND WATER MANAGEMENT TO
CONTROL MOISTURE OF SOILS.
14.COMPACTED "B" BORROW BACK FILL REQUIRED OVER ALL UTILITIES IN PAVED AREAS.
15.ALL UTILITY STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT AND
SHALL HAVE TRAFFIC BEARING RING AND COVERS.
16.COORDINATE LOCATIONS AND CONNECTIONS OF BUILDING STORM LINES WITH
PLUMBING DRAWINGS.
17.FOLLOW ALL LOCAL AND STATE CODES IN REFERENCE TO STORM SEWER
INSTALLATION.
18.ALL EXISTING MANHOLE AND CATCH BASIN GRATES SHALL BE ADJUSTED TO NEW
FINISH GRADE ELEVATIONS.
19.EXISTING PIPES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED OUT TO REMOVE
ALL SILT AND DEBRIS.
20.ALL STORM PIPE CONNECTIONS AT STRUCTURES SHALL BE GROUTED TO ASSURE
CONNECTION AT STRUCTURE IS WATERTIGHT.
21.ALL STORM SEWER STRUCTURES IN PAVED AREAS SHALL BE FLUSH WITH PAVEMENT
AND SHALL HAVE TRAFFIC BEARING RING AND COVERS.
22.ALL STORM SEWER STRUCTURES SHALL HAVE A SMOOTH UNIFORM POURED MORTAR
CHANNEL FROM INVERT IN TO INVERT OUT.
23.NEW PIPES AND STRUCTURES WITHIN CONSTRUCTION LIMITS ARE TO BE CLEANED
OUT TO REMOVE ALL SILT AND DEBRIS PRIOR TO FINAL TURNOVER TO THE OWNER.
24.ALL HDPE PIPE SHALL BE DUAL WALLED, HANCOR HQ, ADS N-12 PIPE OR APPROVED
EQUAL.
25.ALL FITTINGS AND ACCESSORIES INCLUDING BUT NOT LIMITED TO END CAPS,
CLEANOUTS, REDUCERS, ETC., SHALL BE OF HDPE MATERIAL COMPARABLE WITH
STORAGE PIPES.
26.PROVIDE BACKFILL WITH A MINIMUM OF 4" BEDDING MATERIAL OF #8 AGGREGATE
COMPACTED IN 8" LIFTS TO 95% MAXIMUM DRY DENSITY.
27.VERIFY EXISTING STORM INVERT ELEVATIONS PRIOR TO STARTING NEW STORM
SEWER CONNECTION.
28.ALL ON-SITE STORM SYSTEM WILL BE PRIVATE.
29.ALL MANHOLE AND INLET CASTINGS MUST BE PRE-STAMPED WITH "NO DUMPING
DRAINS TO WATERWAY."REVISIONS AND ISSUESPart of the NE/4 of Section 7, Township 17 North, Range 3 East, Clay Township, Hamilton County, IndianaW18.0330PREPARED FOR:10255 COMMERCE DRIVEPROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:MLTDESIGNED BY:DWG NAME:PROJECT NO.:W18.0330DATEBY03.31.2019MLTDATE:RLWKnow what's below.
before you dig.Call
R LINK OFFICE SUITESSUBMITTAL TO CARMEL ADLS/DP09.21.2018MLTW
S
N
E
STEVEN SCOTT RUCKER P.E. 11300279ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMREVISED FOR TAC COMMENTS11.21.2018MLTREVISED FOR TAC COMMENTS12.05.2018MLTREVISED FOR TAC COMMENTS01.02.2019RLWREVISED FOR TAC COMMENTS01.08.2019RLWREVISED SANITARY SEWER LATERAL03.13.2019RLWFINAL CONSTRUCTION PLANS03.31.2019RLW03.31.2019
CARMEL REQUIREMENTS
1.NO EARTH DISTURBING ACTIVITY MAY TAKE PLACE WITHOUT AN
APPROVED STORM WATER MANAGEMENT PERMIT.
2.DECORATIVE SIGNS, SPRINKLER SYSTEMS, TREES, LANDSCAPING
MOUNDS, FENCES, LIGHT POLES OR OTHER SUCH AMENITIES ARE
NOT PERMITTED WITHIN THE RIGHT-0F-WAY.
3.M.F.P.G. = MINIMUM FLOOD PROTECTION GRADE M.F.P.G. OF ALL
STRUCTURES FRONTING A POND OR OPEN DITCH SHALL BE NO
LESS THAN 2 FEET ABOVE ANY ADJACENT 100-YEAR LOCAL OR
REGIONAL FLOOD ELEVATIONS, WHICHEVER IS GREATER, FOR ALL
WINDOWS, DOORS, PIPE ENTRANCES, WINDOW WELLS, AND ANY
OTHER STRUCTURE MEMBER WHERE FLOOD WATERS CAN ENTER A
BUILDING.
4.M.L.A.G. = LOWEST ADJACENT GRADE IS THE ELEVATION OF THE
LOWEST GRADE ADJACENT TO A STRUCTURE WHEN THE SOIL
MEETS THE FOUNDATION AROUND THE OUTSIDE OF THE
STRUCTURE. (INCLUDING STRUCTURAL MEMBERS SUCH AS
BASEMENT WALKOUT, PATIOS, DECKS, PORCHES, SUPPORT POST,
OR PIERS, AND RIM OF THE WINDOW WELL.
8
9