HomeMy WebLinkAboutC603 STORM SEWER DETAILSSECTION A-A CONC. PIPE TOE ANCHOR 12" C TO C MAX. SPACING E+2T GROOVED ON OUTLET END, TONGUE END ON INLET END. GROOVE (OR TONGUE) TO BE THE SAME AS ON STANDARD REINFORCED CONCRETE PIPE, ASTM DESIGNATION C-76. CLASS "A" CONCRETE3" 6" NOTE: METAL PIPE END SECTIONS MAY BE USED WITH CONCRETE PIPE, PROVIDING THE METHOD OF CONNECTION IS APPROVED BY THE ENGINEER PRIOR TO INSTALLATION OF PIPE. (EXCEPT IN INDIANAPOLIS)12" C. TO C.MAX. SPA.CL9" 6" DIA. CONCRETE IN THESE END SECTIONS SHALL BE THE SAME GRADE AND STRENGTH AS SPECIFIED FOR REINFORCED CONCRETE PIPE, A.S.T.M. DESIGNATION C-76 CLASS II, (AS SET OUT IN INDOT STANDARD SPECIFICATIONS). REINFORCEMENT IN THE "C" PORTION SHALL BE THE SAME AS SPECIFIED FOR REINFORCED CONCRETE, A.S.T.M. DESIGNATION C-76 CLASS II, FOR THE SIZE OF CONNECTING PIPE. REINFORCEMENT IN THE "B" PORTION SHALL HAVE A CROSS SECTIONAL AREA EQUAL TO THAT OF ONE LAYER OF STEEL IN THE "C" PORTION. THE END OF THE PIPE CULVERT SHALL BE PLACED IN THE CONCRETE END SECTION SO THAT THE FLOW LINES ARE FLUSH. THE JOINT SHALL BE COMPLETELY FILLED WITH MORTAR. IN 3:1 OR 4:1 FILL SLOPE, CHANGE TO THE SLOPE OF THE END SECTION IN A SMOOTH, PLEASING TRANSITION APPROXIMATELY 10'-0" IN LENGTH. VARIATIONS IN DIMENSIONS - THE THICKNESS OF THE CONCRETE, THE POSITION OF STEEL, AND THE INTERNAL DIAMETER OF THE PIPE SHALL CONFORM WITH THE VARIATIONS IN DIMENSIONS AS PROVIDED IN THE SPECIFICATIONS FOR REINFORCED CONCRETE CULVERT, STORM DRAIN, AND SEWER PIPE, A.S.T.M. DESIGNATION C-??? WHERE VITRIFIED CLAY CULVERT OR CAST IRON CULVERT PIPE IS USED, A "PIPE END SECTION" COMPARABLE TO THAT AS SHOWN FOR METAL OR CONCRETE SHALL BE FURNISHED AND SHALL BE AS APPROVED BY THE ENGINEER, EXCEPT IN AREAS OF ACID OR MINE WATER THEN THE USE OF METAL END SECTION IS PROHIBITED. END SECTIONS WILL BE PAID FOR AT THE CONTRACT UNIT PRICE EACH FOR "PIPE END SECTION" COMPLETE. CONCRETE PIPE TOE ANCHORS SHALL BE REQUIRED ON ALL CONCRETE PIPE END SECTIONS. THE COST THEREOF SHALL BE INCLUDED IN THE CONTRACT UNIT PRICE PER EACH FOR "PIPE END SECTION." RIP-RAP TO BE PLACED ON SIDE SLOPE WHEN CALLED FOR ON PLANS. END SECTION LENGTH (D)PAY LENGTH OF CULVERT COMPUTED LENGTH OF CULVERT CONCRETE END SECTION PIPE CULVERT HOOK BOLTS LONGITUDINAL SECTION C603STORM SEWER DETAILSw180330-C602 drainage det(NO SCALE) 1 1/2"R.1 1/2"R.TTY Y TT4:1 FILL SL O P E 3:1 F I L L S L O P E CLASS "A" CONC.2'-0"TADIA - 1'TDIA - 1'TC B=(D-C) D C SLOPE DETAIL PLAN VIEW SECTION Y-Y PRECAST CONCRETE END SECTION DETAIL2'-0"R2 DIA.R 1 REVISIONS AND ISSUESPart of the NE/4 of Section 7, Township 17 North, Range 3 East, Clay Township, Hamilton County, IndianaW18.0330PREPARED FOR:10255 COMMERCE DRIVEPROJECT NO. SHEET NO.CHECKED BY:DRAWN BY:MLTDESIGNED BY:DWG NAME:PROJECT NO.:W18.0330DATEBY03.31.2019MLTDATE:RLWLINK OFFICE SUITESSUBMITTAL TO CARMEL ADLS/DP09.21.2018MLTSTEVEN SCOTT RUCKER P.E. 11300279ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMREVISED FOR TAC COMMENTS11.21.2018MLTREVISED FOR TAC COMMENTS12.05.2018MLTREVISED FOR TAC COMMENTS01.02.2019RLWREVISED FOR TAC COMMENTS01.08.2019RLWREVISED SANITARY SEWER LATERAL03.13.2019RLWFINAL CONSTRUCTION PLANS03.31.2019RLW03.31.2019 WEIR HEIGHT=880.33 18" RCP36" RCP 14" HDPE14" HDPEINV=880.00 INV=879.90 DIVERSION STRUCTURE DETAIL (NO SCALE) STRUCTURE 202 84" DIAMETER MANHOLE