HomeMy WebLinkAboutC107 SWPPP DETAILSEROSION CONTROL BLANKET
STAPLE PATTERN
1.PREPARE SOIL BEFORE INSTALLING ROLLED EROSION CONTROL PRODUCTS (RECP's), INCLUDING
ANY NECESSARY APPLICATION OF LIME, FERTILIZER, AND SEED. NOTE: WHEN USING CELL-O-SEED
DO NOT SEED PREPARED AREA. CELL-O-SEED MUST BE INSTALLED WITH PAPER SIDE DOWN.
2.BEGIN AT THE TOP OF THE SLOPE BY ANCHORING THE RECP'S IN A 6" (15 CM) DEEP X 6" (15 CM)
WIDE TRENCH WITH APPROXIMATELY 12" (30 CM) OF RECP'S EXTENDED BEYOND THE UP-SLOPE
PORTION OF THE TRENCH. ANCHOR THE RECP'S WITH A ROW OF STAPLES/STAKES
APPROXIMATELY 12" (30 CM) APART IN THE BOTTOM OF THE TRENCH. BACKFILL AND COMPACT
THE TRENCH AFTER STAPLING. APPLY SEED TO COMPACTED SOIL AND FOLD REMAINING 12" (30
CM) PORTION OF RECP'S BACK OVER SEED AND COMPACTED SOIL. SECURE RECP'S COVER
COMPACTED SOIL WITH A ROW OF STAPLES/STAKES SPACED APPROXIMATELY 12" (30 CM) APART
ACROSS THE WIDTH OF THE RECP'S.
3.ROLL THE RECP'S (A.) DOWN OR (B.) HORIZONTALLY ACROSS THE SLOPE. RECP'S WILL UNROLL
WITH APPROPRIATE SIDE AGAINST THE SOIL SURFACE. ALL RECP's MUST BE SECURELY FASTENED
TO SOIL SURFACE BY PLACING STAPLES/STAKES IN APPROPRIATE LOCATIONS AS SHOWN IN THE
STAPLE PATTERN GUIDE. WHEN USING THE DOT SYSTEM , STAPLES/STAKES SHOULD BE PLACED
THOUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE
PATTERN.
4.THE EDGES OF PARALLEL RECP's MUST BE STAPLED WITH APPROXIMATELY 2" - 5" (5 CM - 12.5 CM)
OVERLAP DEPENDING ON RECP's TYPE.
5.CONSECUTIVE RECP'S SPLICED DOWN THE SLOPE MUST BE PLACED END OVER END (SHINGLE
STYLE) WITH AN APPROXIMATE 3" (7.5 CM) OVERLAP. STAPLE THROUGH OVERLAPPED AREA,
APPROXIMATELY 12" (30 CM) APART ACROSS ENTIRE RECP's WIDTH. NOTE: IN LOOSE SOIL
CONDITIONS, THE USE OF STAPLE R STAKE LENGTHS GREATER THAN 6" (15 CM) MAY BE
NECESSAY TO PROPERLY SECURE THE RECP's.
2"-5" (5 CM-12.5CM)
12" (30 CM)6" (15 CM)6" (15 CM)
SLOPE INSTALLATION
DETAIL OF INLET
SEDIMENT CONTROL DEVICE
VELCRO CLOSURE
LIFT STRAPS USED
FOR EASY
MOVEMENT AND
INSPECTION OF UNIT
STORM SEWER GRATE
R
STORM
SEWER
GRATE
Ò
Ò
Mechanical Properties Test Method Units MARV
Grab Tensile Strength ASTM D 4632 kN (lbs)1.62 (365) X 0.89 (200)
Grab Tensile Elongation ASTM D 4632 %24 X 10
Puncture Strength ASTM D 4833 kN (lbs)0.40 (90)
Mullen Burst Strength ASTM D 3786 kPa (psi)3097 (450)
Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.51 (115) X 0.33 (75)
UV Resistence ASTM D 4355 %90
Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40)
Flow Rate ASTM D 4491 1/min/m (gal/min/ft )5907 (145)
Permittivity ASTM D 4491 Sec 2.1-1
22
Ò
Ò
RDANDY BAG
STORM
SEWER
GRATE
REINFORCED
CORNERS
MANAGEABLE
2 FOOT
CONTAINMENT
AREA
LIFT
STRAPS
OPTIONAL
OVERFLOW
PORTS
DUMPING
STRAPS
STORM
INLET
DETAIL OF DROP INLET SEDIMENT CONTROL DEVICE
Ô
Ô
Ô
Grab Tensile Strength ASTM D 4632 kN (lbs)1.78 (400) x 1.40 (315)
Grab Tensile Elongation ASTM D 4632 %15 x 15
Puncture Strength ASTM D 4833 kN (lbs)0.67 (150)
Mullen Burst Strength ASTM D 3786 kPa (psi)5506 (800)
Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.67 (150) x 0.73 (165)
UV Resistence ASTM D 4355 %90
Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40)
Flow Rate ASTM D 4491 1/min/m (gal/min/ft )2852 (70)
Permittivity ASTM D 4491 Sec 0.90-1
22
Ô
Grab Tensile Strength ASTM D 4632 kN (lbs)1.62 (365) X 0.89 (200)
Grab Tensile Elongation ASTM D 4632 %24 X 10
Puncture Strength ASTM D 4833 kN (lbs)0.40 (90)
Mullen Burst Strength ASTM D 3786 kPa (psi)3097 (450)
Trapezoid Tear Strength ASTM D 4533 kN (lbs)0.51 (115) X 0.33 (75)
UV Resistence ASTM D 4355 %90
Apparent Opening Size ASTM D 4751 Mm (US Std Sieve)0.425 (40)
Flow Rate ASTM D 4491 1/min/m (gal/min/ft )5907 (145)
Permittivity ASTM D 4491 Sec 2.1-1
22
Ô
C107SWPPP DETAILSw193004-C106 swppp det(NO SCALE)
(NO SCALE)
EROSION CONTROL Products
Guaranteed SOLUTIONS
14649 HIGHWAY 41 NORTH
EVANSVILLE, IN 47725
800-720-2040
www.nagreen.com
(NO SCALE)
GENERAL STAPLE RECOMMENDATIONS
STAPLE PATTERNS APPLY TO ALL NORTH AMERICAN GREEN EROSION CONTROL BLANKETS.
STAPLE PATTERNS MAY VARY DEPENDING UPON SOIL TYPE AND AVERAGE ANNUAL RAINFALL.
AT SLOPE LENGTHS GREATER THAN 300 FEET OR WHERE DRAINAGE OVER LARGE AREAS
IS DIRECTED ONTO THE BLANKETS, STAPLE PATTERN "C" SHOULD BE UTILIZED.
CHANNEL LININGS REQUIRED A 2.0' MINIMUM OVERLAP AT LONGITUDINAL JOINTS.
SIDESLOPES SHALL REQUIRE A 6" MINIMUM OVERLAP. WHERE OVERLAPS OCCUR,
THE UPSTREAM BLANKET SHALL OVERLAP THE DOWNSTREAM.
IF OTHER THAN NORTH AMERICAN GREEN EROSION CONTROL BLANKETS ARE INSTALLED
FOLLOW THE INSTALLATION DIRECTIONS RECOMMENDED BY THAT PRODUCTS COMPANY.
CHANNEL LININGS UTILIZE STAPLE PATTERN
"C" WITH ADDITIONAL STAPLES ON SIDE SLOPES.
1 1/2 STAPLE PER SQ. YD.
2 STAPLE PER SQ. YD.
ADDITIONAL STAPLES
AS REQUIRED
SLOPE GRADIENT
CHANNEL
LININGSLOPE LENGTH IN FEET300
275
250
225
200
175
150
125
100
75
50
25 1 STAPLE PER SQ. YD.
DANDY BAG
(NO SCALE)
Ô
NOTE: REFER TO DROP INLET PROTECTION DETAIL THIS SHEET
FOR INSTALLATION AND MAINTENANCE REQUIREMENTS.
INSTALLATION: REMOVE THE GRATE FROM CATCH BASIN. IF USING OPTIONAL OIL ABSORBENTS; PLACE
ABSORBENT PILLOW IN UNIT. STAND THE GRATE ON END. MOVE THE TOP LIFTING STRAPS OUT OF THE WAY
AND PLACE THE GRATE INTO THE DANDY BAG®II SO THAT THE GRATE IS BELOW THE TOP STRAPS AND ABOVE
THE LOWER STRAPS. HOLDING THE LIFTING DEVICES, INSERT THE GRATE INTO THE INLET.
MAINTENANCE: REMOVE ALL ACCUMULATED SEDIMENT AND DEBRIS FROM VICINITY OF UNIT AFTER EACH
STORM EVENT. AFTER EACH STORM EVENT AND AT REGULAR INTERVALS, LOOK INTO THE DANDY BAG®II. IF
THE CONTAINMENT AREA IS MORE THAN 1/3 FULL OF SEDIMENT, THE UNIT MUST BE EMPTIED. TO EMPTY UNIT,
LIFT THE UNIT OUT OF THE INLET USING THE LIFTING STRAPS AND REMOVE THE GRATE. IF USING OPTIONAL
OIL ABSORBENTS; REPLACE ABSORBENT WHEN NEAR SATURATION.
STANDARD FABRIC IS AN
ORANGE WOVEN
MONOFILAMENT
DANDY BAG®II
REVISIONS AND ISSUESPart of Section 9, Township 17 North, Range 4 East, Clay Township, Hamilton County, IndianaW19.3004PREPARED FOR:5140 E 96TH ST, INDIANAPOLIS, IN 46240PROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JLKDESIGNED BY:DWG NAME:PROJECT NO.:W19.03004DATEBY05.15.2019FAPDATE:FAPAPP
R
O
V
AL PE
N
DI
N
G
NOT FOR CONSTRUCTIONMARTIN MARIETTA MATERIALS, INC.ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMNORTH INDY OFFICE BUILDINGREVISED PER CARMEL TAC COMMENTS06.26.2019FAP1KOIR WATTLE INLET PROTECTION
KOIR WATTLE
1" X 1" X 24"
HARDWOOD STAKES
2'
S
P
A
C
I
N
G
INLET GRATE OR
NYLOPLAST GRATE
ROCK CHECK DAM
GEOTEXTILE
FILTER FABRIC
GEOTEXTILE
FILTER FABRIC
GEOTEXTILE
FILTER FABRIC
GEOTEXTILE
FILTER FABRIC
INDOT #5 AGGREGATE
(UPSTREAM FACE)
INDOT #5 AGGREGATE
12" LAYER
(UPSTREAM FACE)
CLEAN STONE
NOTE
1.REFERENCED IN CHAPTER 7 PAGE 97 IN THE INDIANA STORM WATER QUALITY MANUAL.
GENERAL RULE FOR SPACING:
THE ELEVATION OF THE BOTTOM
OF THE UPSTREAM BERM SHOULD
BE EQUAL TO THE ELEVATION OF
THE TOP OF THE SUCCEEDING
DOWNSTREAM BERM.
CHECK DAMS IN SWALE
TOP OF BANK
FLOW LINE
UPSTREAM VIEW DOWNSTREAM VIEW
ELEVATION A ELEVATION B
INSTALLATION
1.LAY OUT THE LOCATION OF THE CHECK DAM.
2.EXCAVATE A CUTOFF TRENCH INTO THE CHANNEL BOTTOM AND DITCH BANKS, EXTENDING IT A
MINIMUM OF 18 INCHES BEYOND THE TOP OF THE DITCH BANK.
3.INSTALL AND ANCHOR FILTER FABRIC IN THE CHANNEL AND CUTOFF TRENCH.
4.PLACE RIPRAP IN THE CUTOFF TRENCH AND CHANNEL TO THE LINES AND DIMENSIONS SHOWN IN THE
CONSTRUCTION PLANS. THE CENTER OF EACH DAM MUST BE AT LEAST NINE INCHES LOWER THAN THE
UPPERMOST POINTS OF CONTACT BETWEEN THE RIPRAP DAM AND CHANNEL BANKS (SEE ROCK
CHECK DAM WORKSHEET ON PAGE 101).
5.EXTEND THE RIPRAP AT LEAST 18 INCHES BEYOND THE TOP OF THE CHANNEL BANKS TO KEEP
OVERFLOW WATER FROM ERODING AREAS ADJACENT TO THE CHANNEL BANKS BEFORE IT RE-ENTERS
THE CHANNEL.
6.PLACE FILTER MEDIUM (INDOT CA NO. 5 AGGREGATE) ON THE UP-SLOPE SIDE OF THE DAM. PLACE
FILTER MEDIUM OVER THE ENTIRE FACE OF THE DAM UP TO THE BASE OF THE OVERFLOW WEIR
NOTCH.
7.STABILIZE THE CHANNEL ABOVE THE UPPERMOST DAM.
8.INSTALL AN EROSION-RESISTANT LINING IN THE CHANNEL BELOW THE LOWERMOST DAM. THE LINING
SHOULD EXTEND A MINIMUM DISTANCE OF SIX FEET BELOW THE DAM.
9.ADDITIONAL SEDIMENT STORAGE CAN BE PROVIDED BY EXCAVATING A SMALL SEDIMENT TRAP ON THE
UPSTREAM SIDE OF THE CHECK DAM.
MAINTENANCE
- INSPECT WITHIN 24 HOURS OF EACH RAIN EVENT AND AT LEAST ONCE EVERY SEVEN CALENDAR DAYS.
- IF SIGNIFICANT EROSION OCCURS BETWEEN DAMS, INSTALL AN EROSION-RESISTANT LINER IN THAT
PORTION OF THE CHANNEL.
- REMOVE ACCUMULATED SEDIMENT WHEN IT REACHES ONE-HALF THE HEIGHT OF THE DAM TO MAINTAIN
CHANNEL CAPACITY, ALLOW DRAINAGE THROUGH THE DAM, AND PREVENTLARGE FLOW FROM DISPLACING
SEDIMENT.
- ADD RIPRAP AND AGGREGATE AS NEEDED TO MAINTAIN DESIGN HEIGHT AND CROSS SECTION OF THE
DAMS.
- WHEN DAMS ARE NO LONGER NEEDED, REMOVE THE RIPRAP AND AGGREGATE ANDSTABILIZE THE
CHANNEL, USING AN EROSION-RESISTANT LINING IF NECESSARY. (RIPRAP AND AGGREGATE FROM THE
DAM MAY BE REMOVED OR UTILIZED TO STABILIZE THE CHANNEL.)
FOR SWALES AND DITCHES(NO SCALE)
FLOW
MAX. 2:1 MAX. 2:1
INDOT #5 AGGREGATE
12" LAYER
(UPSTREAM FACE)
CLEAN STONE
FLOW
MAX. 2:1 MAX. 2:1
2 ACRES OR LESS OF DRAINAGE AREA
WATER FLOW
Z=%
RIPRAP
RIPRAP
SEASONAL SOIL PROTECTION CHART
PERMANENT
SEEDING
SODDING
MULCHING
METHOD
STABILIZATION
SOIL
SEEDING
DORMANT
SEEDING
TEMPORARY
A = KENTUCKY BLUEGRASS* 40 LBS/ACRE; CREEPING RED FESCUE 40 LBS/ACRE;
PLUS 2 TONS STRAW MULCH/ACRE, OR ADD ANNUAL RYEGRASS 20 LBS/ACRE.
B = KENTUCKY BLUEGRASS* 60 LBS/ACRE; CREEPING RED FESCUE 60 LBS/ACRE;
PLUS 2 TONS STRAW MULCH/ACRE, OR ADD ANNUAL RYEGRASS 30 LBS/ACRE.
C = SPRING OATS 3 BUSHEL/ACRE.
D = WHEAT OR RYE 2 BUSHEL/ACRE.
E = ANNUAL RYEGRASS 40 LBS/ACRE.
F = SOD (BLEND 3 IMPROVED VARIETIES).
G = STRAW MULCH 2 TONS/ACRE.
*/I/* IRRIGATION NEEDED DURING JUNE, JULY, AND/OR SEPTEMBER.
** IRRIGATION NEEDED FOR 2 TO 3 WEEKS AFTER APPLYING SOD.
*KENTUCKY BLUEGRASS BLEND OF 3 IMPROVED VARIETIES.
NOTE: NOT PERMITTED WITHIN CITY RIGHT-OF-WAY
NOTE: NOT PERMITTED WITHIN CITY RIGHT-OF-WAY