HomeMy WebLinkAboutC501 SANITARY SEWER DETAILSC501SANITARY SEWER DETAILSREVISIONS AND ISSUESPart of Section 9, Township 17 North, Range 4 East, Clay Township, Hamilton County, IndianaW19.3004PREPARED FOR:5140 E 96TH ST, INDIANAPOLIS, IN 46240PROJECT NO.
SHEET NO.CHECKED BY:DRAWN BY:JLKDESIGNED BY:DWG NAME:PROJECT NO.:W19.03004DATEBY05.15.2019FAPDATE:FAPAPP
R
O
V
AL PE
N
DI
N
G
NOT FOR CONSTRUCTIONMARTIN MARIETTA MATERIALS, INC.ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMNORTH INDY OFFICE BUILDINGREVISED PER CARMEL TAC COMMENTS06.26.2019FAP16" MIN No. 8 STONE 12" X 12" X 4" THK.
CONCRETE BLOCK
NOT TO SCALE
ISOLATION VALVE
FUSION CONNECTION
6"-8" PVC (TO BE CUT
TO LENGTH AND
NOTCH PVC AT THE
BOTTOM TO FIT OVER
MAIN & VALVE)
FUSION
CONNECTION
10 GAUGE
TRACER WIRE (TYP.)
COVER/LID #SIGMA CORPORATION VB-284
(VB-2841S) OR EQUAL
MATERIAL: CAST IRON ASTM A4B CLASS-25B
GRANULAR BACKFILL
NOT TO SCALE
TRACER STATION
6" PVC (TO BE CUT TO
LENGTH AND NOTCH
PVC AT THE BOTTOM
TO FIT OVER MAIN)
10 GAUGE
TRACER WIRE (TYP.)
COVER/LID #SIGMA
CORPORATION VB-284
(VB-2841S)
MATERIAL: CAST IRON
ASTM A4B CLASS-25B
4" MIN. CONCRETE PAD
20" FRACTO
HDPE SMOOTH
CORR METER PIT
6" MIN. No. 8 STONE
3" FEMALE CAM-LOCK W/DUST
CAP (316 SS RATED @ 200 PSI)
ISOLATION VALVE
(SEE DETAIL THIS SHEET)
FLOW
10 GAUGE
TRACER WIRE (TYP.)
GRADE
20" COVER W/ SMALL
OPERATION NUT
LPSS MAIN
(HPDE IPS DR-11)
LPSS FLUSHING MAIN
(HPDE DR-11)
REDUCER, REQ'D IF LPSS MAIN DIA.
VARIES FROM FLUSHING MAIN DIA.
SECTION VIEW
18"
6" MIN No. 8 STONE
FLOW
HDPE 3 SEGMENT WYEPLAN VIEW
NOT TO SCALE
TYPE II - IN-LINE
FLUSHING CONNECTION FLOWFUSION CONNECTION
2" LPSS MAIN
(HPDE DR-11)
CONCRETE BASE20" COVER W/ SMALL
OPERATION NUT
FLUSHING CONNECTION
W/ 3" FEMALE CAM-LOCK
LPSS MAIN
(HPDE IPS DR-11)
FUSION
CONNECTION
FUSION CONNECTION
(2) "B" BORROW OR EQUIV.
GRANULAR MATERIAL
COMPACTED TO 95%
STANDARD PROCTOR DENSITY
#8 CRUSHED STONE OR
APPROVED EQUIVALENT
CLASS I BEDDING MATERIAL
HAND TAMPED OR WALKED
INTO PLACE
TYPICAL BEDDING SECTION - PVC & HDPE
ALL BEDDING & INITIAL BACKFILL SHALL
BE INSTALLED IN 6" TO 12" BALANCED
LIFTS A MIN. 9" CLEARANCE SHALL BE
PROVIDED ON EACH SIDE OF THE
INSTALLED PIPE
Bc = OUTSIDE DIAMETER
D = INSIDE DIAMETER
D = DEPTH OF BEDDING
MATERIAL BELOW PIPE
(1) REGULAR BACKFILL
GREATER THAN 5' (1)
EDGE OF PAVEMENT,
CURB, GUTTER OR
SIMILAR STRUCTURE IN
THE PUBLIC
RIGHT-OF-WAY
MIN. 6" TOPSOIL TO ENSURE
GRASS GROWTH IF NOT UNDER
PAVEMENT
12" MIN.Bc
(NO SCALE)4"BURIED VALVES
2.01 ISOLATION VALVE AND LATERAL ASSEMBLY VALVES
1.ISOLATION VALVE SHALL BE E-ONE STAINLESS STEEL UNI-LATERAL CHECK/BALL VALVE.
2. THE VALVE SHALL BE SUITABLE FOR USE UP TO 235 PSI.
3.THE VALVE OPERATION SHALL BE 1/4 TURN CLOCKWISE USING A 2" SQUARE NUT.
4.THE VALVE SHALL BE COMPATIBLE FOR HEAT FUSION WITH SIMILAR HDPE PIPE AND MATERIALS.
5.VALVE SHALL BE MARKED WITH THE FOLLOWING INFORMATION:
a) NOMINAL PIPE SIZE
b) PIPE PRESSURE RATING
d) MANUFACTURER'S NAME, TRADEMARK AND CODE
6.VALVES SHALL BE MANUFACTURED BY E-ONE CORPORATION, OR APPROVED EQUAL.
2.02 CHECK VALVES:
1.SMALL DIAMETER SWING CHECK VALVES SHALL BE 200 PSI RATED, 316 STAINLESS STEEL, AS
MANUFACTURED BY E-ONE CORPORATION OR APPROVED EQUAL.
SEWAGE FORCEMAINS
2.08 LOCATION/TRACER WIRE:
1.DIRECTIONAL TRACER WIRE SHALL BE #10-AWG SOLID, COPPER-CLAD STEEL CORE (11,150 LB.
AVERAGE TENSILE BREAK LOAD) WITH 45 MIL HIGH DENSITY POLYETHYLENE "GREEN" COLOR
INSULATING JACKET COMPLYING WITH ASTM D1248, 30 VOLT RATING. THE WIRE SHALL BE
CONTINUOUS WITH NO FABRICATED OR FIELD CONSTRUCTION CONNECTIONS INTERRUPTING THE
WIRES CONTINUITY FROM END TO END. WIRE INSULTATION SHALL BE HIGHLY RESISTANT TO ACIDS,
ALKALIS, AND OTHER DESTRUCTIVE SUBSTANCES FOUND IN SOIL.
2.TRACER WIRE SHALL BE AS MANUFACTURED BY COPPERHEAD INDUSTRIES, LLC, OR APPROVED
EQUAL.
3.TRACER WIRE SPLICE KITS SHALL BE LOCKING SNAKEBITE CORROSION PROOF WIRE CONNECTION
AS MANUFACTURED BY COPPERHEAD INDUSTRIES, LLC OR APPROVED EQUAL.
2.09 TRACER WIRE STATION:
1.PIPELINE TRACER WIRE STATIONS WITH ACCESS TO RECEIVE TRACER WIRE SHALL BE LOCATED
ALONG THE SEWAGE FORCEMAIN ROUTE AS SHOWN ON THE DRAWINGS. ADDITIONAL STATIONS MAY
BE INSTALLED AS REQUIRED DUE TO RECEIVING PIT LOCATIONS DURING CONSTRUCTION. TRACER
STATIONS SHALL BE CONSTRUCTED OF SUPERIOR GRADE PVC PLASTIC MATERIAL, SCHEDULE 40, 6"
DIAMETER, WITH LID. "SEWER" SHALL BE CLEARLY PRINTED ON THE LID. LID SHALL BE OF CAST IRON
(ASTM A4B CLASS-25B) MODEL VB-284 (VB-2841S) AS MANUFACTURED BY SIGMA CORPORATION OR
APPROVED EQUAL.
2.TRACER STATION SHALL BE INSTALLED FLUSH WITH FINISH GRADE AND LOCATED OVER PIPE LINE
TO WHICH TRACER LEAD IS ATTACHED.
3. LOCATION WIRE SHALL BE LOOPED UP INTO TRACER STATIONS, AND ISOLATION VALVE BOXES, FOR
CONNECTION TO A LOCATING DEVISE (MAXIMUM 800' OF FORCEMAIN BETWEEN TRACER
STATIONS/VALVE BOXES AND EACH SIDE OF LEGAL DRAIN). THE WIRE SHALL BE ONE CONTINUOUS
PIECE FROM END TO END.
4.CONTRACTOR SHALL TEST TRACER WIRE USING OWNER'S LOCATING DEVICE AFTER INSTALLATION
OF PIPE TO ENSURE CONTINUITY FROM END TO END. IF TRACER WIRE IS FOUND NOT TO BE
CONTINUOUS AFTER TESTING, CONTRACTOR SHALL REPAIR OR REPLACE THE FAILED SEGMENT OF
THE WIRE AT HIS OWN EXPENSE.
3.16 TESTING (HDPE PIPE)
1.ALL NEW HDPE SANITARY SEWER FORCEMAIN SHALL BE HYDROSTATIC TESTED TO ENSURE WATER
TIGHTNESS AND INTEGRITY IN ACCORDANCE WITH ASTM F2164 "STANDARD PRACTICE FOR FIELD
LEAK TESTING OF POLYETHYLENE (PE) PRESSURE PIPING SYSTEMS USING HYDROSTATIC
PRESSURE".
2.THE OWNER SHALL WITNESS ALL TESTS.
E-ONE STAINLESS STEEL
UNIT-LATERAL CHECK/BALL
VALVE. SEE DETAIL THIS
SHEET.
E-ONE STAINLESS STEEL
UNIT-LATERAL CHECK/BALL
VALVE. SEE DETAIL THIS
SHEET.
E-ONE STAINLESS STEEL
UNIT-LATERAL CHECK/BALL
VALVE. SEE DETAIL THIS
SHEET.
LPSS MAIN
(HPDE IPS DR-11)
LPSS MAIN
(HPDE IPS DR-11)
NOTE: CONTRACTOR TO COORDINATE WITH CITY OF CARMEL SEWER (JASON STEWART @ 317-571-2634)
PRIOR TO PURCHASING AND INSTALLATION OF FLUSHING UNIT.