Loading...
HomeMy WebLinkAboutC601 STORM SEWER PLAN AND PROFILEE E E E E EE OHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUOHUSAN SAN S A N SANSAN SAN SAN SAN SAN SAN SAN SAN SAN SANSAN EEEWWWW WFMFMFM F M F M E E 15MATCH LINE C600MATCH LINE C601720 725 730 735 740 745 750 755 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 STORM 100-102 MATCH LINE C600MATCH LINE C601OHUOHUOHUOHUOHUOHUWWWWWWWG G G G G G G FOFOFOFOFOFOWGWWWWWWWWEEEEDDD730 735 740 745 750 730 735 740 745 750 -0+50 0+00 0+50 1+00 STORM 400-401 STORM SEWER STRUCTURE DATA TABLE STRUCTURE NUMBER 100 102 103 104 105 106 107 200 201 202 300 301 302 303 400 401 STRUCTURE TYPE ??? MANHOLE MANHOLE MANHOLE MANHOLE INLET TYPE A INLET TYPE A MANHOLE MANHOLE ??? INLET TYPE A MANHOLE INLET TYPE A INLET TYPE A ??? ??? TOP OF CASTING -4.54 741.00 741.00 739.28 739.80 739.38 741.40 739.00 739.65 738.42 741.00 737.17 740.00 739.40 -2.14 -1.92 CASTING TYPE ??? NEENAH R-1642 NEENAH R-3405 NEENAH R-3405 NEENAH R-3405 NEENAH R-3405 NEENAH R-3405 NEENAH R-3405 NEENAH R-3405 ??? NEENAH R-4342 NEENAH R-1642 NEENAH R-1642 NEENAH R-3405 ??? ??? INVERT INV IN = 733.50(N) INV IN = 734.46(N) INV IN = 734.46(NW) INV IN = 734.40(SW) INV OUT = 734.15(S) INV IN = 735.20(W) INV IN = 736.00(NE) INV OUT = 735.10(S) INV IN = 735.74(N) INV OUT = 735.64(E) INV IN = 736.01(N) INV OUT = 735.91(S) INV IN = 736.71(E) INV OUT = 736.54(S) INV OUT = 737.90(W) INV IN = 735.03(W) INV OUT = 734.93(SE) INV IN = 735.51(W) INV OUT = 735.41(E) INV OUT = 735.80(E) INV OUT = 736.50(SW) INV IN = 736.00(N) INV IN = 736.65(W) INV OUT = 736.55(S) INV IN = 737.40(N) INV OUT = 736.80(E) INV IN = 736.00(N) INV OUT = 736.00(S) DETAIL LOCATION END SECTION N/AN/A END SECTION N/AN/A END SECTION N/AN/A END SECTION N/AN/A END SECTION N/AN/A SEE CONCRETE END SECTION DETAIL ON C603 SEE STANDARD STORM MANHOLE DETAIL ON C603 SEE STANDARD STORM MANHOLE DETAIL ON C603 SEE STANDARD STORM MANHOLE DETAIL ON C603 SEE INLET TYPE A DETAIL ON C603 SEE STANDARD STORM MANHOLE DETAIL ON C603 SEE CONCRETE END SECTION DETAIL ON C603 SEE CONCRETE END SECTION DETAIL ON C603 SEE CONCRETE END SECTION DETAIL ON C603 SEE CONCRETE END SECTION DETAIL ON C603 SEE INLET TYPE A DETAIL ON C603 SEE INLET TYPE A DETAIL ON C603 SEE STANDARD STORM MANHOLE DETAIL ON C603 SEE INLET TYPE A DETAIL ON C603 SEE INLET TYPE A DETAIL ON C603 SEE STANDARD STORM MANHOLE DETAIL ON C603 STORM SEWER PIPE DATA TABLE UPSTREAM STRUCTURE 102 103 104 105 106 107 200 201 202 300 301 302 303 401 DOWNSTREAM STRUCTURE 102 100 102 103 104 105 106 102 200 201 103 302 303 400 SIZE 6" 36" 21" 21" 18" 15" 12" 27" 27" 27" 12" 12" 12" 12" 27" MATERIAL HDPE RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP RCP CMP RCP LENGTH 2' 308' 212' 147' 58' 151' 233' 70' 56' 43' 99' 196' 37' 32' 80' SLOPE 4.00% 0.21% 0.30% 0.30% 0.29% 0.35% 0.51% 0.67% 0.67% 0.68% 0.50% 0.28% 0.40% 1.57% 0.00%160' C601STORM SEWER PLAN AND PROFILEN W E S REVISIONS AND ISSUESPart of Section 9, Township 17 North, Range 4 East, Clay Township, Hamilton County, IndianaW19.3004PREPARED FOR:5140 E 96TH ST, INDIANAPOLIS, IN 46240PROJECT NO. SHEET NO.CHECKED BY:DRAWN BY:JLKDESIGNED BY:DWG NAME:PROJECT NO.:W19.03004DATEBY05.15.2019FAPDATE:FAPKnow what's below. before you dig.Call R APP R O V AL PE N DI N G NOT FOR CONSTRUCTIONMARTIN MARIETTA MATERIALS, INC.ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMNORTH INDY OFFICE BUILDINGREVISED PER CARMEL TAC COMMENTS06.26.2019FAP1REVISED PER CARMEL TAC COMMENTS07.29.2019FAP2LEGEND EXISTING GRADE FINISHED GRADE HYDRAULIC GRADE LINE NOTE: THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. GRANULAR BACKFILL - SEE SHEET C603 FOR BACKFILL DETAILS NOTE: SEE SHEET C600 FOR LEGEND, ABBREVIATIONS AND GENERAL STORM SEWER NOTES. NOTE: FROM STA 0+16 TO 0+64 CLASS V PIPE REQUIRED