HomeMy WebLinkAboutC603 STORM SEWER DETAILSSECTION A-A CONC. PIPE TOE ANCHOR 12" C TO C MAX. SPACING E+2T GROOVED ON OUTLET END, TONGUE END ON INLET END. GROOVE (OR TONGUE) TO BE THE SAME AS ON STANDARD REINFORCED CONCRETE PIPE, ASTM DESIGNATION C-76. CLASS "A" CONCRETE3" 6" NOTE: METAL PIPE END SECTIONS MAY BE USED WITH CONCRETE PIPE, PROVIDING THE METHOD OF CONNECTION IS APPROVED BY THE ENGINEER PRIOR TO INSTALLATION OF PIPE. (EXCEPT IN INDIANAPOLIS)12" C. TO C.MAX. SPA.E9" 6" DIA. CONCRETE IN THESE END SECTIONS SHALL BE THE SAME GRADE AND STRENGTH AS SPECIFIED FOR REINFORCED CONCRETE PIPE, A.S.T.M. DESIGNATION C-76 CLASS III, (AS SET OUT IN INDOT STANDARD SPECIFICATIONS). REINFORCEMENT IN THE "C" PORTION SHALL BE THE SAME AS SPECIFIED FOR REINFORCED CONCRETE, A.S.T.M. DESIGNATION C-76 CLASS III, FOR THE SIZE OF CONNECTING PIPE. REINFORCEMENT IN THE "B" PORTION SHALL HAVE A CROSS SECTIONAL AREA EQUAL TO THAT OF ONE LAYER OF STEEL IN THE "C" PORTION. THE END OF THE PIPE CULVERT SHALL BE PLACED IN THE CONCRETE END SECTION SO THAT THE FLOW LINES ARE FLUSH. THE JOINT SHALL BE COMPLETELY FILLED WITH MORTAR. IN 3:1 OR 4:1 FILL SLOPE, CHANGE TO THE SLOPE OF THE END SECTION IN A SMOOTH, PLEASING TRANSITION APPROXIMATELY 10'-0" IN LENGTH. VARIATIONS IN DIMENSIONS - THE THICKNESS OF THE CONCRETE, THE POSITION OF STEEL, AND THE INTERNAL DIAMETER OF THE PIPE SHALL CONFORM WITH THE VARIATIONS IN DIMENSIONS AS PROVIDED IN THE SPECIFICATIONS FOR REINFORCED CONCRETE CULVERT, STORM DRAIN, AND SEWER PIPE, A.S.T.M. DESIGNATION C-76 WHERE VITRIFIED CLAY CULVERT OR CAST IRON CULVERT PIPE IS USED, A "PIPE END SECTION" COMPARABLE TO THAT AS SHOWN FOR METAL OR CONCRETE SHALL BE FURNISHED AND SHALL BE AS APPROVED BY THE ENGINEER, EXCEPT IN AREAS OF ACID OR MINE WATER THEN THE USE OF METAL END SECTION IS PROHIBITED. END SECTIONS WILL BE PAID FOR AT THE CONTRACT UNIT PRICE EACH FOR "PIPE END SECTION" COMPLETE. CONCRETE PIPE TOE ANCHORS SHALL BE REQUIRED ON ALL CONCRETE PIPE END SECTIONS. THE COST THEREOF SHALL BE INCLUDED IN THE CONTRACT UNIT PRICE PER EACH FOR "PIPE END SECTION." RIP-RAP TO BE PLACED ON SIDE SLOPE WHEN CALLED FOR ON PLANS. END SECTION LENGTH (D)PAY LENGTH OF CULVERT COMPUTED LENGTH OF CULVERT CONCRETE END SECTION PIPE CULVERT HOOK BOLTS LONGITUDINAL SECTION MANHOLE (DIA. "F") PIPES ENTERING/ LEAVING AT 0-45 DEGREES FINISH GRADE OR PAVEMENT MANHOLE (DIA. "F") PIPES ENTERING/ LEAVING AT 45-90 DEGREES PIPE SIZE (DIA. "G") CASTING FRAME & COVER AS SPECIFIED ASPHALTIC MASTIC OR BUTYL RUBBER SEAL BETWEEN ALL JOINTS. STANDARD PRECAST MANHOLE CAP OR ECCENTRIC CONE. (UP TO 24" PIPE.) FULL HEIGHT MANHOLE STEPS AS REQUIRED. CONCRETE REDUCER CAP PRECAST CONC. ADJUSTER RINGS, IF NEEDED (12 MAX.) BENCHWALLS AT MINIMUM 12" PERFOOT SLOPE. BENCHWALLS TO BE CONSTRUCTED TO SPRINGLINE OF PIPE. INVERT ELEVATION BASE SHALL BE POURED IN PLACE OR PRECAST. BOTH SHALL HAVE #4 BARS-12" O.C. BOTH WAYS. BASE SET ON 6" OF #8 OR #2 STONE DIAMETER "G" DIAMETER "F" 4'-0" DIA. 24" DIA.24" DIA.PREFORMED HOLE TO MAX OF PIPE O.D. + 6" WITH NON-SHRINK CEMENT GROUT NOTE MANHOLE STEPS SHALL BE POLYPROPYLENE, POLYPROPYLENE COATED STEEL REINFORCING OR AN APPROVED NON-CORROSIVE FIBERGLASS MATERIAL. THE COPOLYMER POLYPROPYLENE SHALL MEET THE REQUIREMENTS OF ASTM D-4101 REINFORCED WITH DEFORMED 38" MIN. DIAMETER REINFORCED STEEL CONFORMING TO THE REQUIREMENTS OF ASTM A-615, GRADE 60. NON-COATED CAST IRON STEPS ARE NOT ACCEPTABLE. UP TO 60 DEGREES SUB-SURFACE UNDERDRAIN TILE SECTION 18" MIN.12"/14" TRENCH C603STORM SEWER DETAILSw193004-C602 drainage det(NO SCALE) 1 1/2"R.1 1/2"R.TTY Y TT4:1 FILL SL O P E 3:1 F I L L S L O P E CLASS "A" CONC.2'-0"TADIA - 1'TDIA - 1'TC B=(D-C) D C 16" (TYP.) 5" 6" NOTE ·MANHOLE CONFORMS TO ASTM C-478 ·NO BRICK OR BLOCK WILL BE ALLOWED IN MANHOLE ·O-RING GASKET ASPHALTIC MASTIC OR BUTYL RUBBER SEAL BETWEEN MANHOLE JOINTS 3"MIN. 3"MIN. 6" for 48" Dia 8" for > 48" Dia (NO SCALE) STANDARD STORM MANHOLE SLOPE DETAIL PLAN VIEW SECTION Y-Y PRECAST CONCRETE END SECTION DETAIL 12"-21" 24" 27"-30" 33"-36" 42" 48" 54" 60" 66"N/A N/A N/A 84" 72" 60" 60" 48" 48"48" 60" 60" 72" 84" 96" N/A N/A N/A 96" 96" 96" N/A N/A N/A N/A N/A N/A 2'-0"R2 DIA.R 1 REQUIREMENTS FOR ALL STORM SEWER BENCHWALLS BENCH WALLS SHALL BE SHAPED AND FORMED FOR A CLEAN TRANSITION WITH PROPER HYDRAULICS TO ALLOW THE SMOOTH CONVEYANCE OF FLOWS THROUGH THE MANHOLE OR BOX INLET. THE BENCH WALL SHALL FORM A DEFINED CHANNEL, TO A MINIMUM HEIGHT OF 80-PERCENT OF THE INSIDE DIAMETER OF THE INLET AND OUTLET PIPES TO FORM A "U" SHAPED CHANNEL, CONSTRUCTED AT A MINIMUM ½-INCH PER FOOT SLOPE TO THE MANHOLE WALL. WHERE A FLOW CHANNEL IS CONSTRUCTED AS AN INTEGRAL PART OF THE PRE-CAST BASE, IT SHALL BE SHAPED AND FORMED AS DESCRIBED ABOVE, WITH THE EXCEPTION THAT THE BOTTOM OF THE FLOW CHANNEL MAY BE FORMED FROM THE BOTTOM OF INLET AND OUTLET PIPES IF THE PIPE WALL THICKNESS IS NOT GREATER THAN ONE (1) INCH. FOR CAST-IN-PLACE FLOW CHANNELS, THE BOTTOM INVERT OF ALL PIPES ENTERING A MANHOLE SHALL BE AT LEAST THREE (3) INCHES ABOVE THE TOP OF THE BASE SLAB TO THE OUTLET INVERT SO THE FINISHED SEWER CHANNEL MAY BE INSTALLED AND SHAPED. FOR CONNECTIONS TO EXISTING STORM SEWER STRUCTURES, FLOW CHANNELS SHALL BE SHAPED, AS SPECIFIED HEREIN, AS IF IT WERE A NEW MANHOLE OR BOX INLET STRUCTURE. SPECIFICATIONS FOR ALL STORM SEWER CASTINGS ALL STORM WATER INLETS AND CATCH BASINS SHALL HAVE THE WORDS "NO DUMPING, DRAINS TO STREAM", OR SIMILARLY APPROVED MESSAGE, CAST IN RAISED OR RECESSED LETTERS AT A MINIMUM OF 1" IN HEIGHT. IN ADDITION, A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS. 1/6 Bc (NO SCALE) Bc d d(MIN.) 66" & LARGER 30" TO 60" 27" & SMALLER D 6 4 3 GREATER THAN 5' (1) LESS THAN 5' (2) B = OUTSIDE DIAMETER D = INSIDE DIAMETER d = DEPTH OF BEDDING MATERIAL BELOW PIPE TYPICAL BEDDING SECTION - RCP PIPE MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT. (1) MIN. 1.25 Bc(2) 1.25 Bc + 12" (MIN.) EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE. (1) REGULAR BACKFILL (2) "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY. "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY. NOTE: 1) ALL BEDDING & INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS. 2) A MIN. OF 9" CLEARANCE SHALL BE PROVIDED ON EACH SIDE OF THE INSTALLED PIPE. PAVED AREA INLET TYPE "A" (MODIFIED) (NO SCALE) TOP OF CASTING ELEVATION E.J. 5250 NEENAH R-3405 OR EQUAL PAVEMENT PIPE SIZES 12" TO 15" "DUMP NO WASTE-DRAINS TO WATERWAY"SLOPESLOPE SLOPESLOPE6" CONCRETE 3'-0"3'-0"3'-0"3'-0"6" CL CL6"6"6" E.J. 5250 NEENAH R-3405 OR EQUAL CLASS "A" CONCRETE SECTION VARIES(4.0' MAX.)INLET SET ON 6" BASE OF #8 STONE NOTES: 1. 6" CONCRETE PRECAST OR POURED IN PLACE 2. REFER TO BEDDING DETAIL AS REQUIRED 3. VAR. PIPE SIZE 15" MAX STRAIGHT CONNECTIONS 12" MAX SKEW/CORNER CONNECTIONS 4. PIPE CONNECTION TO BE SEALED WITH NON-SHRINK GROUT 5. STRAIGHT-OUT CONNECTIONS SHOULD NOT BE MADE TO EITHER PRECAST BOX OR INLET WALL TOUCHED BY A SKEW/CORNER CONNECTION UNLESS SUFFICIENT BOX INLET WALL AREA REMAINS ON EACH SIDE OF THE CONNECTING PIPE TO ENSURE STRUCTURAL INTEGRITY OF THE PRECAST BOX. 6. A MAXIMUM OF ONE (1) SKEW/CORNER CONNECTION WILL BE ALLOWED FOR EACH PRECAST BOX INLET. 7. REFER TO PRECAST CONCRETE ADJUSTING RING DETAIL AS REQUIRED 2 REBAR #5 3.5' EA. WALL ADJUSTING RING AS REQUIRED MIN. 4000 PSI SAWCUT JOINT (TYPICAL) BEEHIVE INLET TYPE "A" (NO SCALE) CLASS "A" CONCRETE SECTION VARIES(4.0' MAX.)INLET SET ON 6" BASE OF #8 STONE "DUMP NO WASTE-DRAINS TO WATERWAY" TOP OF CASTING ELEVATION E.J. 6489 NEENAH R-4342 OR EQUAL NOTES: 1. 6" CONCRETE PRECAST OR POURED IN PLACE 2. REFER TO BEDDING DETAIL AS REQUIRED 3. VAR. PIPE SIZE 12" MAX STRAIGHT CONNECTIONS ONLY 4. PIPE CONNECTION TO BE SEALED WITH NON-SHRINK GROUT 5. REFER TO PRECAST CONCRETE ADJUSTING RING DETAIL AS REQUIRED PIPE SIZES UP TO 12" ADJUSTING RING AS REQUIRED 2 REBAR #5 3.5' EA. WALL REVISIONS AND ISSUESPart of Section 9, Township 17 North, Range 4 East, Clay Township, Hamilton County, IndianaW19.3004PREPARED FOR:5140 E 96TH ST, INDIANAPOLIS, IN 46240PROJECT NO. SHEET NO.CHECKED BY:DRAWN BY:JLKDESIGNED BY:DWG NAME:PROJECT NO.:W19.03004DATEBY05.15.2019FAPDATE:FAPAPP R O V AL PE N DI N G NOT FOR CONSTRUCTIONMARTIN MARIETTA MATERIALS, INC.ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMNORTH INDY OFFICE BUILDINGREVISED PER CARMEL TAC COMMENTS06.26.2019FAP1REVISED PER CARMEL TAC COMMENTS07.29.2019FAP2TOP ELEVATION - SEE GRADING PLAN SECTION DO NOT FORM BELOW GRADE. CONCRETE (TYPE A, 4000PSI) SLOTTED DRAIN NOT TO SCALE 14 GAGE SLOTTED DRAIN PIPE 12" DIA. WITH 6" HIGH SLOT MANUFACTURED BY: CONTECH ENGINEERING SOLUTIONS, LLC. PREFERRED OR EQUIVALENT PRODUCT. FOR SLOT HEIGHTS 7" TO 18" CONTACT ENGINEERING REPRESENTATIVE #4 BAR (TYP.) #53 AGGREGATE AS REQUIRED FROM UNDISTURBED GRADE TYPICAL SWALE SECTION (NO SCALE) (2) "B" BORROW OR EQUIV. GRANULAR MATERIAL COMPACTED TO 95% STANDARD PROCTOR DENSITY #8 CRUSHED STONE OR APPROVED EQUIV. CLASS I BEDDING MATERIAL HAND TAMPED OR WALKED INTO PLACE TYPICAL BEDDING SECTION - PVC & HDPE (NO SCALE)4"ALL BEDDING & INITIAL BACKFILL SHALL BE INSTALLED IN 6" TO 12" BALANCED LIFTS A MIN. 9" CLEARANCE SHALL BE PROVIDED ON EACH SIDE OF THE INSTALLED PIPE Bc = OUTSIDE DIAMETER D = INSIDE DIAMETER D = DEPTH OF BEDDING MATERIAL BELOW PIPE (1) REGULAR BACKFILL GREATER THAN 5' (1) EDGE OF PAVEMENT, CURB, GUTTER OR SIMILAR STRUCTURE IN THE PUBLIC RIGHT-OF-WAY LESS THAN 5' (2) 1.25 Bc + 12" (MIN.) MIN. 6" TOPSOIL TO ENSURE GRASS GROWTH IF NOT UNDER PAVEMENT 12" MIN.Bc