HomeMy WebLinkAboutC7.0.DetailsOUTLET CONTROL STRUCTURE
STRUCTURE #OC1
PROJECT NUMBER
DRAWING NUMBER
SHEET OF
SCALE:
DATE:
DWN BY:
CHKD. BY:CIVIL SITE GROUP, INC.GROUP, INC.PROF
E
SS
IONA L E NG INEERIND
IA NA
PE10910647
STATE OF
-oN
R E G ISTERE
DBR IA N S CR
O
S
SSBL.003
C7.0CARMEL, INDIANA 460334630 LISBON DRIVESIGMA BUILDERS, LLC.GENERAL DETAILSCOOMBS PROPERTY REDEVELOPMENTNW CORNER OF SHOSHONE DRIVE & OSWEGO ROADCARMEL, INDIANA 4603204/20/2018
REVISION RECORD
IN (24")
STR. #FYOC - 5 FT DIA. OUTLET CONTROL STRUCTURE
INV.-844.50
IN
5' DIAMTER
MANHOLE (MIN.)
INV=844.50 (E-24")
PLAN VIEW
6" THICK REINFORCED
CONCRETE ORIFICE
CONTROL WALL
WEIR WALL ORIFICE DETAILS
INV.-844.50
ELEV.-844.83ININV=844.50 (N-24")TW=846.50
INV.-844.50
844.50
843.50 OUTINV=844.50 (SW-8")PRECAST CONCRETE FLARED END SECTION
SECTION A-A VERTICAL FLARE
SECTION B-B
HORIZONTAL FLARE
STORM SEWER INLET NOTE
ALL STORM WATER INLETS & CATCH BASIN
CASTINGS SHALL BE LABELLED WITH
ENVIRONMENTAL MESSAGING "NO DUMPING,
DRAINS TO WATERWAY" CAST IN RAISED OR
RECESSED LETTERS AT A MIN. 1-INCH HEIGHT.
A SYMBOL OF A FISH SHALL ALSO BE CAST
WITH THE LETTERS.
OUT (8")
PLASTIC PIPE (PVC & HDPE)
BEDDING/TRENCH DETAIL
FOAM GASKET W/
PSA BACKING
(TRIM TO LENGTH)
MOUNTING
FLANGE
DETAIL B
GASKET
COMPRESSED
BETWEEN HOOD
AND STRUCTURE
(SEE DETAIL B)
INSTALLATION NOTE:
POSITION HOOD SUCH THAT
BOTTOM FLANGE IS A
DISTANCE OF 1/2 OUTLET
PIPE DIAMETER (MIN.)
BELOW THE PIPE INVERT.
MINUMUM DISTANCE FOR
PIPES < 12" I.D. IS 6".
STAINLESS
BOLT
ANCHOR
SHIELD
EXPANSION CONE
(NARROW END OUT)
DRILLED
HOLE
DETAIL A
ANCHOR W/ BOLT
(SEE DETAIL A)
1/2 D
NOTES:
1. ALL HOODS AND TRAPS FOR CATCH BASINS AND WATER QUALITY STRUCTURES SHALL BE
AS MANUFACTURED BY:
BEST MANAGEMENT PRODUCTS, INC.
53 MT. ARCHER RD.
LYME, CT 06371
(860) 434-0277, (860) 434-3195 FAX
TOLL FREE: (800) 504-8008 OR (888) 434-0277
WEB SITE: www.bmpinc.com
OR PRE-APPROVED EQUAL
2. ALL HOODS SHALL BE CONSTRUCTED OF A GLASS REINFORCED RESIN COMPOSITE WITH
ISO GEL COAT EXTERIOR FINISH WITH A MINIMUM 0.125" LAMINATE THICKNESS.
3. ALL HOODS SHALL BE EQUIPPED WITH A WATERTIGHT ACCESS PORT, A MOUNTING FLANGE,
AND AN ANTI-SIPHON VENT PIPE AND ELBOW AS DRAWN. (SEE CONFIGURATION DETAIL)
4. THE SIZE AND POSITION OF THE HOOD SHALL BE DETERMINED BY OUTLET PIPE SIZE AS
PER MANUFACTURER'S RECOMMENDATION (SNOUT SIZE ALWAYS LARGER THAN PIPE SIZE).
5. THE BOTTOM OF THE HOOD SHALL EXTEND DOWNWARD A MINIMUM DISTANCE EQUAL TO
1/2 THE OUTLET PIPE DIAMETER WITH A MINIMUM DISTANCE OF 6" FOR PIPES <12" I.D.
6. THE ANTI-SIPHON VENT SHALL EXTEND ABOVE HOOD BY MINIMUM OF 3" AND A MAXIMUM OF
12" ACCORDING TO STRUCTURE CONFIGURATION.
7. THE SURFACE OF THE STRUCTURE WHERE THE HOOD IS MOUNTED SHALL BE FINISHED
SMOOTH AND FREE OF LOOSE MATERIAL AND PIPE SHALL BE FINISHED FLUSH TO WALL.
8. THE HOOD SHALL BE SECURELY ATTACHED TO STRUCTURE WALL WITH 3/8' STAINLESS
STEEL BOLTS AND OIL-RESISTANT GASKET AS SUPPLIED BY MANUFACTURER. (SEE
INSTALLATION DETAIL)
9. INSTALLATION INSTRUCTIONS SHALL BE FURNISHED WITH MANUFACTURER SUPPLIED
INSTALLATION KIT.
INSTALLATION KIT SHALL INCLUDE:
A. INSTALLATION INSTRUCTIONS
B. PVC ANTI-SIPHON VENT PIPE AND ADAPTER
C. OIL-RESISTANT CRUSHED CELL FOAM GASKET WITH PSA BACKING
D. 3/8" STAINLESS STEEL BOLTS
E. ANCHOR SHIELDS
*NOTE- SEE NOTE*EMERGENCY OVERFLOW WEIR
BMP, INC.
53 MT. ARCHER ROAD, LYME, CT. 06371
(800) 504-8008 FAX: (860)434-3195
DESIGNED TO FIT
60"-72" DIAM.
STRUCTURES
STORM MANHOLE