HomeMy WebLinkAboutC3.1.Storm Sewer Plan & ProfilesF.F.E. = 755.70 (NAVD 88 DATUM) Equality Blvd.Community DriveDETENTION SWALE WITH WHITE RIVER AT FLOOD STAGE 100-YEAR BASE FLOOD ELEVATION = 751.57 (NAVD 88 DATUM) 100-YEAR BASE FLOOD ELEVATION = 752.00 (NGVD 29 DATUM) A/C A/CEXISTING 12" PVC ROOF DRAIN PIPE202 200 PROPOSED GYM & LEARNING CENTER 13,000± S.F. F.F.E. = 755.70 (NAVD 88 DATUM) F.F.E. = 755.70 (NAVD 88 DATUM) EXISTING CURB INLET (RAISE EX. CASTING ELEVATION TO PROPOSED GRADE) T.C. = 753.50 GUT = 753.00 INV. = 748.1± (18" PVC - N) INV. = 748.1± (EX. 12" - E) INV. = 748.0± (EX. 18" - S) EXISTING CURB INLET T.C. = 754.21 GUT = 753.71 INV. = 749.3± (EX. 12" - N) INV. = 749.2± (EX. 15" - S) EXISTING CONC. END SECTION INV. = 747.5± (EX. 18" RCP - N) 600 601 100 101 102 103 CONNECT 6" PVC DRAIN TO EX. ROOF DRAIN PIPE E2 EXISTING STORM INLET T.C. = 753.35 INV. = 748.65± (EX. 12" PVC - NE) INV. = 748.5± (EX. 12" RCP - W) INV. = 748.15± (10" PVC - SE) STORM MANHOLE - 4'Ø T.C. = 754.50 INV. = 749.17± (EX. 15" - NE) INV = 749.2± (12" PVC - S) INV. = 749.07 (15" RCP - W) E1 EXISTING CURB INLET T.C. = 754.15 GUT = 753.65 INV. = 749.34± (EX. 12" - S) STORM MANHOLE - 4'Ø T.C. = 755.60 INV. = 748.63 (15" RCP - E) INV. = 748.53 (15" RCP - S) CURB INLET MANHOLE - 4'Ø T.C. = 753.25 GUT = 752.75 INV. = 748.27 (15" RCP - N) INV. = 748.17 (18" RCP - SE) 4'Ø CURB INLET MANHOLE w/ 2' SUMP T.C. = 752.50 GUT = 752.0 INV. = 747.79 (18" RCP - NW) INV. = 747.69 (18" RCP - S) CONCRETE END SECTION w/ RIP-RAP. SEE DETAIL 18/C7.0 INV. = 747.57126 L.F. of 18" RCP @ 0.30% 48 L.F. of 18" RCP @ 0.24%114 L.F. of 15" RCP @ 0.23%177 L.F. of 15" RCP @ 0.25% 12± L.F. of EX. 15" RCP R6 R18 RD CDR10 R10R6 R8 EXISTING SCHOOL BUILDING MLAG/MFPG = TOP OF CURB = 754.45 EXISTING FIRE SERVICE LINE TO BE LOWERED AT STORM SEWER CROSSING 6" NDS #918B YARD DRAIN T.C.=754.5± 15± L.F. of 6" SDR35 PVC 30' T T EXISTING 40" RCPEXISTING 18" RCPRD R12 RCO RCO RCO R12 R18 C C R12 R8 RD R6 R6 R8 R12 STORM SEWER PROFILE EXISTING FIRE SERVICE LINE TO BE LOWERED (CONTRACTOR TO FIELD VERIFY LOCATION/ELEVATION PRIOR TO COMMENCING WITH CONSTRUCTION) EX. 15" RCP CONNECT 12" PVC ROOF DRAIN PIPE 2' SUMP REQ'D EXISTING TELECOM TO BE RELOCATED IN THE VICINITY OF STR #103 TO #102 (CONTRACTOR TO FIELD VERIFY LOCATION/ELEVATION PRIOR TO COMMENCING WITH CONSTRUCTION) PROJECT NUMBER DRAWING NUMBER SHEET OF SCALE: DATE: DWN BY: CHKD. BY:CIVIL SITE GROUP, INC.GROUP, INC.PROF E SS IONA L E NG INEERIND IA NA PE10910647 STATE OF -oNREGISTEREDBRIANSCR O S STPS.007 C3.1NOBLESVILLE, INDIANA 4606015575 STONY CREEK WAYTHE PLAY SCHOOL at LEGACY, INC.STORM SEWER PLAN & PROFILETHE PLAY SCHOOL at LEGACY SPORT COURT14454 COMMUNITY DRIVECARMEL, INDIANA 4603306/22/2018 CONTRACTOR NOTE NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. TOPOGRAPHIC & BOUNDARY NOTE UTILITY LOCATE NOTE LEGEND: GENERAL NOTES GENERAL NOTES CONTRACTOR TO KEEP EXISTING PAVEMENT SURROUNDING THE SITE (I.E. COMMUNITY DRIVE & EQUALITY BLVD.) "BROOM CLEAN" AND FREE OF SOIL OR AGGREGATE THAT MIGHT BE BROUGHT OFF-SITE. DEPENDING ON THE CONSTRUCTION SEASON, MOISTURE CONTENT AND PROPERTIES OF THE SOILS ON SITE, CHEMICAL MODIFICATIONS AND/OR LIME STABILIZATION MAY BE REQUIRED. SEE SHEET C9.0 FOR SPECIFICATIONS. ALL CONCRETE PIPE JOINTS SHALL BE CONTINUOUS O-RING RUBBER GASKET CONFORMING TO ASTM C 443 CONTRACTOR (NOT THE PROJECT SITE OWNER) WILL BE RESPONSIBLE FOR THE DISPOSAL OF ANY SOIL, MATERIALS, ETC. NO OFF-SITE BORROWS OR STOCKPILES WILL BE NEEDED FOR THIS PROJECT. CONTRACTOR SHALL SUBMIT PRECAST STORM SEWER STRUCTURE SHOP DRAWINGS TO ENGINEER FOR REVIEW/APPROVAL PRIOR TO MANUFACTURING. STORM PLAN - 1"=30' 18 " OF VERTICAL SEPARATION MUST BE MAINTAINED FOR ALL UTILITY CROSSINGS. ALL CONCRETE PIPE JOINTS SHALL BE CONTINUOUS O-RING RUBBER GASKET CONFORMING TO ASTM C 443 STORM SEWER INLET NOTE ALL STORM WATER INLETS & CATCH BASIN CASTINGS SHALL BE LABELLED WITH ENVIRONMENTAL MESSAGING "NO DUMPING, DRAINS TO STREAM" CAST IN RAISED OR RECESSED LETTERS AT A MIN. 1-INCH HEIGHT. A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS NOTE EXISTING RIGHT-OF-WAY NOTE DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. UTILITY VALVE NOTE STORM SEWER SYSTEM NOTE ALL STORM SEWER INFRASTRUCTURE TO BE CONSTRUCTED WITH THE PROJECT LIMITS SHALL BE PRIVATELY OWNED AND MAINTAINED BY THE PLAY SCHOOL at LEGACY, INC. STORM SEWER SYSTEM NOTE STORM BACKFILL NOTE STRUCTURE DATA TABLE REVISION RECORD PLAN NOTES: R8 C R10 R12 T 2CD RD RCO R6 R18 2 2