HomeMy WebLinkAboutTPS007.C0.0.Title SheetSITE
THE PLAY SCHOOL at LEGACY SPORT COURT
14454 COMMUNITY DRIVE
CIVIL CONSTRUCTION PLANS
PROJECT DEVELOPER:
CARMEL, INDIANA 46033
C0.0
VICINITY MAP
SHEET OF
PROJECT NUMBER
DRAWING NUMBER
TPS.007
PROJECT VICINITY
160 W. Carmel Drive, Suite 240
Carmel, Indiana 46032
Phone: (317) 810-1677 Fax: (317) 810-1679
GROUP, INC
06/22/2018
THE PLAY SCHOOL at LEGACY
15575 STONY CREEK WAY
NOBLESVILLE, INDIANA 46060
SURVEYOR:
CONSTRUCTION PLAN INDEX
LAND DESCRIPTION
A PART OF THE NORTHWEST QUARTER OF SECTION 23, TOWNSHIP 18 NORTH, RANGE 4 EAST, CLAY TOWNSHIP, HAMILTON
COUNTY, INDIAN, BEING MORE PARTICULARLY DESCRIBED AS BELOW:
COMMENCING AT THE NORTHEAST CORNER OF SAID QUARTER SECTION; THENCE NORTH 89 DEGREES 03 MINUTES 27
SECONDS WEST ALONG THE NORTH LINE OF SAID QUARTER SECTION A DISTANCE OF 715.41 FEET TO THE PROLONGED
WESTERLY RIGHT-OF-WAY LINE OF COMMUNITY DRIVE RECORDED AS INSTR NO: 2008-43636 IN THE OFFICE OF THE
RECORDER OF HAMILTON COUNTY, INDIANA; THENCE SOUTH 00 DEGREES 00 MINUTES 00 SECONDS WEST 92.83 FEET
ALONG SAID PROLONGED RIGHT-OF-WAY LINE TO A POINT ON THE SOUTHERLY LIMITED ACCESS RIGHT-OF-WAY LINE OF
146TH STREET; THENCE ALONG SAID WESTERLY RIGHT-OF-WAY LINE OF COMMUNITY DRIVE BY THE NEXT SEVEN (7)
COURSES: 1) SOUTH 00 DEGREES 00 MINUTES 00 SECONDS WEST 223.06 FEET TO A POINT OF TANGENCY OF A CURVE
CONCAVE WESTERLY, THE RADIUS POINT OF SAID CURVE BEING NORTH 90 DEGREES 00 MINUTES 00 SECONDS WEST
455.50 FEET: 2) ALONG SAID CURVE 34.64 FEET TO THE POINT OF TANGENCY OF SAID CURVE, SAID POINT BEGINNING
SOUTH 85 DEGREES 38 MINUTES 33 SECONDS EAST 455.50 FEET; 3) SOUTH 04 DEGREES 21 MINUTES 27 SECONDS WEST
242.38 FEET TO THE POINT OF TANGENCY OF A CURVE CONCAVE EASTERLY, THE RADIUS POINT OF SAID CURVE BEING
SOUTH 85 DEGREES 38 MINUTES 33 SECONDS EAST 544.50 FEET; 5) SOUTH 00 DEGREES 00 MINUTES 00 SECONDS EAST
88.34 FEET TO A POINT OF TANGENCY OF A CURVE CONCAVE EASTERLY, THE RADIUS POINT OF SAID CURVE BEING NORTH
90 DEGREES 00 MINUTES 00 SECONDS EAST 544.50 FEET; 6) ALONG SAID CURVE 29.30 FEET TO THE POINT OF TANGENCY
OF SAID CURVE, SAID POINT BEGINNING SOUTH 85 DEGREES 38 MINUTES 33 SECONDS EAST 544.50 FEET; 7) SOUTH 03
DEGREES 04 MINUTES 59 SECONDS EAST 195.88 FEET TO THE POINT OF BEGINNING OF THIS DESCRIPTION; THENCE
SOUTH 03 DEGREES 04 MINUTES 59 SECONDS EAST 243.00 FEET ALONG SAID WESTERLY RIGHT-OF-WAY LINE; THENCE
NORTH 90 DEGREES 00 MINUTES 00 SECONDS WEST 376.00 FEET; THENCE NORTH 00 DEGREES 00 MINUTES 00 SECONDS
EAST 234.67 FEET; THENCE NORTH 90 DEGREES 00 MINUTES 00 SECOND EAST 214.95 FEET; THENCE NORTH 86 DEGREES
54 MINUTES 50 SECONDS EAST 148.20 FEET TO SAID WESTERLY RIGHT-OF-WAY LINE AND THE PLACE OF BEGINNING,
CONTAINING 2.00 ACRES MORE OR LESS.PROF
E
SS
IONAL E NG INEERIND
IA NA
PE10910647
STATE OF
-oN
R E G ISTERE
DBRIANSCR
O
SSREVISION RECORD
DEVELOPMENT SUMMARY
PROPOSED USE: SCHOOL GYMNASIUM & STEM LEARNING FACILITY
TOTAL SITE AREA = 2.01± Ac.
TOTAL DISTURBED AREA = 72,311± SF = 1.7± Ac
PROPOSED TOTAL BUILDING COVERAGE RATIO = 39% OF SITE AREA
PROPOSED IMPERVIOUS AREA SITE INCREASE = 26,400± S.F.
CURRENT ZONING = PUD - THE LEGACY
SETBACK DISTANCES (PROPOSED) BUILDING SETBACK DISTANCES (REQ'D)
FRONT = 0' FRONT = 15' (MAX.)
REAR = 9.4' (EX. BLDG.) REAR = 5' (MIN.)
SIDE = 15' (EX. BLDG.) SIDE = 0' (MIN.)
ANTICIPATED CONSTRUCTION START/COMPLETION DATE
SEPTEMBER 3, 2018 / OCTOBER, 2019
TOTAL PARKING SPACES = 91 (INCLUDES STREET PARKING SPACES)
EXISTING RIGHT-OF-WAY NOTE
DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE
SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR
IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START
OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY.
OPERATING AUTHORITY
CITY OF CARMEL DEPT. OF ENGINEERING
ONE CIVIC SQUARE
CARMEL, INDIANA 46032
PHONE: 317-571-2441 FAX: 317-571-2439
CARMEL ENGINEERING DEPT. NOTE
ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE
REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE
DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE
DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED
INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE
DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY.
BENCHMARK
ENGINEER: