Loading...
HomeMy WebLinkAboutCivil Plans 4.8.19 1311"PAVED AREA INLET TYPE "A" 22"X22" 6" (TYP.)VARIES16" MIN.CLASS "A" CONCRETEDIA.SECTION VARIES(4.0' MAX.)DIA.INLET SET ON 6" BASE OF #8 STONE OR #2 STONE 1.STRAIGHT-OUT CONNECTIONS SHOULD NOT BE MADE TO EITHER PRECAST BOX OR INLET WALL TOUCHED BY A SKEW/CORNER CONNECTION UNLESS SUFFICIENT BOX INLET WALL AREA REMAINS ON EACH SIDE OF THE CONNECTING PIPE TO ENSURE STRUCTURAL INTEGRITY OF THE PRECAST BOX. 2.A MAXIMUM OF TWO (2) SKEW/CORNER CONNECTIONS WILL BE ALLOWED FOR EACH PRECAST BOX INLET. 3.REFER TO PRECAST CONCRETE ADJUSTING RING DETAIL AS REQUIRED 6" (TYP.)8"T.O.C. ELEVATION E.J. 5250 NEENAH R-3405 OR EQUAL NOTES 1.6" CONCRETE PRECAST OR POURED IN PLACE. 2.REFER TO BEDDING DETAIL AS REQUIRED E.J. 5250 NEENAH R-3405 OR EQUAL 14 W180605-C602 DRAINAGE DET - C602w180605-C602 drainage detSLOPESLOPESLOPE 6" CONCRETE SLOPE3'-6"3'-6"3'-6"3'-6" "DUMP NO WASTE-DRAINS TO WATERWAY" PAVEMENT PIPE SIZES 12" TO 15"(NO SCALE) 6"6"6"6"℄ ℄ REQUIREMENTS FOR ALL STORM SEWER BENCHWALLS BENCH WALLS SHALL BE SHAPED AND FORMED FOR A CLEAN TRANSITION WITH PROPER HYDRAULICS TO ALLOW THE SMOOTH CONVEYANCE OF FLOWS THROUGH THE MANHOLE OR BOX INLET. THE BENCH WALL SHALL FORM A DEFINED CHANNEL, TO A MINIMUM HEIGHT OF 80-PERCENT OF THE INSIDE DIAMETER OF THE INLET AND OUTLET PIPES TO FORM A "U" SHAPED CHANNEL, CONSTRUCTED AT A MINIMUM ½-INCH PER FOOT SLOPE TO THE MANHOLE WALL. WHERE A FLOW CHANNEL IS CONSTRUCTED AS AN INTEGRAL PART OF THE PRE-CAST BASE, IT SHALL BE SHAPED AND FORMED AS DESCRIBED ABOVE, WITH THE EXCEPTION THAT THE BOTTOM OF THE FLOW CHANNEL MAY BE FORMED FROM THE BOTTOM OF INLET AND OUTLET PIPES IF THE PIPE WALL THICKNESS IS NOT GREATER THAN ONE (1) INCH. FOR CAST-IN-PLACE FLOW CHANNELS, THE BOTTOM INVERT OF ALL PIPES ENTERING A MANHOLE SHALL BE AT LEAST THREE (3) INCHES ABOVE THE TOP OF THE BASE SLAB TO THE OUTLET INVERT SO THE FINISHED SEWER CHANNEL MAY BE INSTALLED AND SHAPED. FOR CONNECTIONS TO EXISTING STORM SEWER STRUCTURES, FLOW CHANNELS SHALL BE SHAPED, AS SPECIFIED HEREIN, AS IF IT WERE A NEW MANHOLE OR BOX INLET STRUCTURE. SPECIFICATIONS FOR ALL STORM SEWER CASTINGS ALL STORM WATER INLETS AND CATCH BASINS SHALL HAVE THE WORDS "NO DUMPING, DRAINS TO STREAM", OR SIMILARLY APPROVED MESSAGE, CAST IN RAISED OR RECESSED LETTERS AT A MINIMUM OF 1" IN HEIGHT. IN ADDITION, A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS. REV A7001-110-144DWG NO.1 OF 1SHEETNTSSCALEDWG SIZE A 3130 VERONA AVE BUFORD, GA 30518 PHN (770) 932-2443 FAX (770) 932-2490 www.nyloplast-us.com DRAIN BASIN WITH STANDARD GRATE QUICK SPEC INSTALLATION DETAIL TITLE PROJECT NO./NAME MATERIAL DATE APPD BY 1-23-06DATE EBCDRAWN BY 1-23-06 CJA WWW.NYLOPLAST-US.COM 800-821-6710 15"2815AG A 8" 10" 12" 2810AG 2812AG PART # 2808AG GRATE OPTIONS STANDARD LIGHT DUTY PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-25 SOLID LIGHT DUTY SOLID AASHTO H-25 PEDESTRIAN LIGHT DUTY NYLOPLAST DRAIN BASIN STANDARD LIGHT DUTY PEDESTRIAN LIGHT DUTY SOLID LIGHT DUTY PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-25 SOLID AASHTO H-25 A PART #GRATE OPTIONS 18" 24" 30"2830AG 2818AG 2824AG N/A PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-25 SOLID AASHTO H-25 PEDESTRIAN AASHTO H-10 STANDARD AASHTO H-25 SOLID AASHTO H-25 STANDARD AASHTO H-25 SOLID AASHTO H-25 1'1' (NO SCALE) TYPICAL CLEANOUT SECTION OUTSIDE GRADE 4" P.V.C. PIPE 1/8 STREET BEND 4" X 6" INCREASER NOTE: LATERAL CONNECTION TO CLEANOUT STRUCTURE TO BE WITHIN 3.0' (THREE FEET) OF THE FOUNDATION WALL. NEENAH CASTING R-1976 OR EJIW 1578 FOR CLEANOUT IN PAVEMENT. CONCRETE ENCASEMENT WHEN NOT ALREADY IN PROPOSED RIGID SURFACE. CLEANOUT PLUG & ADAPTER 6" HDPE DETAIL IS TYPICAL. REFER TO SHEET C601 FOR STORM SEWER DATA TABLE. DETAIL IS TYPICAL. REFER TO SHEET C601 FOR STORM SEWER DATA TABLE. DETAIL IS TYPICAL. REFER TO SHEET C601 FOR STORM SEWER DATA TABLE. DETAIL IS TYPICAL. REFER TO SHEET C601 FOR STORM SEWER DATA TABLE. CONCRETE CURB TURNOUT REVISIONS AND ISSUESPart of SE/4, Section 26, Township 18 North, Range 3 East, Clay Township, Hamilton County, INW18.0605PREPARED FOR:SOUTHWEST CORNER OF GRAND & MAIN, CARMEL, INPROJECT NO. SHEET NO.CHECKED BY:DRAWN BY:RLWDESIGNED BY:DWG NAME:PROJECT NO.:W18.0605DATEBYSSRDATE:RLWKnow what's below. before you dig.Call R APPROVAL PENDINGNOT FOR CONSTRUCTIONSHOPPES ON MAINSUBMITTED FOR TAC REVIEW10.20.2017RLWSTEVEN SCOTT RUCKER P.E. 11300279ENGINEERS317 | 846 - 6611800 | 452 - 6408317 | 843 - 0546 faxWEIHELand Surveying | Civil EngineeringLandscape ArchitectureALLAN H. WEIHE, P.E., L.S. - FOUNDER10505 N. College AvenueIndianapolis, Indiana 46280weihe.netBuild with confidence.SMPLANS REVISED FOR CARMEL TAC COMMENTS12.08.2017RLWPLANS REVISED FOR REVIEW COMMENTS01.23.2018RLW04.08.2019PLANS REVISED FOR REVIEW COMMENTS02.12.2018RLWPLANS UPDATED FOR STUDIO M ARCHITECTS04.08.2019RLW