HomeMy WebLinkAboutC401 UTILITY PLANMICHIGAN RD(HWY 421)98TH ST (50'PUBLIC ROW) DO NOT ENTERPROPO S E D TAKE 5 OIL CHANG E BUI LDI NG (1,500 SF±) PROPO S E D INFI LTRAT I ON BASIN WITH NATIVE VEGET A TION BOT=879.5 MAX. 100 Y R = 881.3 TOP OF B ANK=88 2 . 3 W W W W PR. D.E . & BMP ESMTPR. D.E. & BMP ESMTPR. D.E . & BMP ESMTPR. D.E. & BMP ESMT W W W W W W W W W W W W W W W W W W W W W W W W W 611 53 LF OF 12" RCP @ 0.30% 612 602 29 LF OF 12" HDPE N12 @ 0.52%ST2 39'±83'± SS1SS2 INV=832.0 SS3 W1 W2 W3 601 74 LF OF 12" RCP @ 0.34% W4 ST4 ST4 621 12 LF OF 12" HDPE N12 @ 2.04% 620 FIELD VERIFY EXACT LOCATION AND DEPTH OF EX. WATER MAIN. NOTIFY ENGINEER IF CONFLICT IS FOUND BETWEEN DESIGN PIPE AND EX. WATER. CORE DRILL AND CONNECT NEW PIPE WITH NON-SHRINK GROUT UX PAVEMENT RESTORATION AFTER TRENCH PIPE INSTALLATION UX 641 34 LF OF 12 " H D P E @ 0.4 4% 640 630 34 LF OF 12" HDPE @ 0.44%631 STORM STRUCTURE DATA TABLE STRUCTURE I.D. 600 601 602 611 612 620 621 630 631 RIM ELEVATION 882.00 881.50 881.30 882.35 882.47 881.69 882.24 -1.60 881.50 NEENAH CASTING DESIGNATION R-1772 R-3472 NYLOPLAST DOME GRATE ??? ??? ??? R-3286-8V ??? DOME GRATE INFLOW INV:877.60 12" RCP (S) INV:877.85 12" HDPE N12 (S) INV:878.00 6" HDPE (W) INV:880.68 12" RCP (W) INV:880.00 12" HDPE N12 (W) INV:879.50 12" HDPE (S) OUTFLOW INV:877.85 12" RCP (N) INV:878.00 12" HDPE N12 (N) INV:880.84 12" RCP (E) INV:880.25 12" HDPE N12 (E) INV:879.65 12" HDPE (N) DESCRIPTION & NOTES EX. MANHOLE 48" PRECAST MH / R-3472 12" NYLOPLAST DRAINAGE STRUCTURE WITH DOME GRATE 12 '' End Section 12 '' End Section 12 '' End Section 2'x2' BOX INLET 24" SUMP W/ SNOUT 12F AND BIO-SKIRT REQ'D 12" METAL END SECTION 12" NYLOPLAST DRAIN BASIN STORM SEWER PIPE DATA TABLE UPSTREAM STRUCTURE I.D. 601 602 612 621 631 641 DOWNSTREAM STRUCTURE I.D. 602 600 601 611 620 630 640 LENGTH OF PIPE 51 LF 74 LF 29 LF 53 LF 12 LF 34 LF 34 LF PIPE SIZE / TYPE 6" HDPE 12" RCP 12" HDPE N12 12" RCP 12" HDPE N12 12" HDPE 12" HDPE SLOPE % 0.00% 0.34% 0.52% 0.30% 2.04% 0.44% 0.44% UPSTREAM PIPE INV. 878.00 877.85 878.00 880.84 880.25 879.65 879.65 DOWNSTREAM PIPE INV. 878.00 877.60 877.85 880.68 880.00 879.50 879.50 PROJECT NO. CHECK: DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com PRELI MIN ARY NOT FOR CONST R UCTI O N Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: GENERAL NOTES / LEGEND: SECTION, TOWNSHIP, RANGE: TAKE 5 QUICK LUBE TAKE 5 INDIANA, LLC 10884 GRESHAM PLACE NOBLESVILLE, INDIANA 46060 5/16/2019 1904001 9799 MICHIGAN RD. CARMEL, INDIANA 46032 HAMILTON COUNTY S7, T17N, R3E SHEET NAME SHEET NO. 0 20' 40' SCALE: 1" = 20' N "IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG. C401 UTILITY PLAN 1.REV. PER TAC CMNTS 7/17/2019 2. REV. PER CARMEL ENG 10/15/2019 3. REV. PER CARMEL ENG 11/5/2019 AF AF AF AF AF KG KEY NOTES: E1 ELECTRIC - CONTRACTOR SHALL COORD. EXACT LOCATION, SIZE OF SERVICE WITH MEP PLANS AND POWER CO. SS1 SANITARY - 6" PVC SDR 26 LATERAL @ 1.04% MIN., SEE PLAN FOR LENGTH SS2 SANITARY - CLEANOUT, TYPE 1, SEE PLAN FOR INVERTS SS3 SANITARY - CONNECT LATERAL TO EX. LATERAL STUB PER TRICO REGIONAL SEWER STANDARDS. VERIFY STUB LOCATION IN FIELD BEFORE CONSTRUCTION. APPROX. LOCATION SHOWN. ST1 STORM - PR. STRUCTURE, REF. STORM STRUCTURE TABLE ST2 STORM - 6" PERF. UNDERDRAIN ST3 STORM - 8" HDPE N12 OUTLET PIPE. DISCHARGE TO DOWNSTREAM ROADSIDE DITCH AS SHOWN. PROVIDE ANIMAL GUARD ON PIPE END. ST4 STORM - BUILDING DOWNSPOUT DISCHARGE TO GRADE. REF. ARCH. PLANS FOR EXACT LOCATIONS AND SIZES/MAT'L. W1 WATER - PR. 1" CORPORATION STOP TAP ON EX. 16" POLY MAIN & CURB STOP PER CARMEL WATER STANDARDS W2 WATER - PR. 1" DOMESTIC WATER SERVICE LINE. TYPE 'K' COPPER. W3 WATER - CONTRACTOR SHALL FIELD VERIFY LOCATION OF EXISTING WATER MAIN PRIOR TO CONSTRUCTION. W4 WATER - DOMESTIC WATER METER LOCATED INSIDE BUILDING. REF. TO MEP PLANS. UX UTILITY CROSSING, APPROX. LOCATION SHOWN. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL EX. UTILITIES WITHIN AREA OF WORK PRIOR TO CONSTRUCTION. ENGINEER SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS FOUND. NOTES: 1. UTILITY CROSSINGS UNDER EX. PAVEMENT SHALL BE BORED OR JACK & BORED WHERE POSSIBLE. OPEN CUTS SHALL BE AVOIDED. 2. CONTRACTOR SHALL CONTACT VECTREN AT 1-800-227-1376 TO HAVE EXISTING GAS SERVICE TO EX. BUILDING DISCONNECTED PRIOR TO DEMOLITION OF STRUCTURE. 6XX XX# DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. EXISTING RIGHT-OF-WAY NOTE ALL STORM WATER INLETS & CATCH BASIN CASTINGS SHALL BE LABELLED WITH ENVIRONMENTAL MESSAGING "NO DUMPING, DRAINS TO STREAM" CAST IN RAISED OR RECESSED LETTERS AT A MIN. 1-INCH HEIGHT. A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS STORM SEWER INLET NOTE ALL STORM SEWER INFRASTRUCTURE TO BE CONSTRUCTED WITH THE PROJECT LIMITS SHALL BE PRIVATELY OWNED AND MAINTAINED BY OWNER. STORM SEWER SYSTEM NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. EXISTING CONDITIONS NOTE 02/19/20