HomeMy WebLinkAboutC402 STORM PLAN & PROFILE98TH ST (50'PUBLIC ROW) DO NOT ENTERPROPO S E D TAKE 5 OIL CHANG E BUILD I N G PROPO S ED INFILT R A T I O N BASIN WITH NA TIVE VEGET A T I O N BOT=87 9 . 5 MAX. 100 YR = 881.3 TOP OF BANK= 8 8 2 . 3 W W W W PR. D.E. & BMP ESMTPR. D.E. & BMP ESMTPR. D.E . & BMP ESMTPR. D.E. & BMP ESMT W W W W W W W W W W W W W W W W W W W W W W W W W 611 53 LF OF 12" RCP @ 0.30% 612 602 29 LF OF 12" HDPE N12 @ 0.52%39'±83'± 601 74 LF OF 12" RCP @ 0.34% 621 12 LF OF 12" HDPE N12 @ 2.04% 620 FIELD VERIFY EXACT LOCATION AND DEPTH OF EX. WATER MAIN. NOTIFY ENGINEER IF CONFLICT IS FOUND BETWEEN DESIGN PIPE AND EX. WATER. CORE DRILL AND CONNECT NEW PIPE WITH NON-SHRINK GROUT PAVEMENT RESTORATION AFTER TRENCH PIPE INSTALLATION 641 34 LF O F 12 " HD P E @ 0.4 4 % 640 630 34 LF OF 12" HDPE @ 0.44%631 PR STORM PROFILE STR. 612-611 870 875 880 885 890 895 900 0+75 1+00 1+00.00 1+50.00 1+73.36 1+75880.72882.75PR STORM PROFILE STR. 621-620 870 875 880 885 890 895 900 -0+25 0+00 0+00.00 0+32.24 0+50 PR STORM PROFILE STR. 602-600 870 875 880 885 890 895 900 0+75 1+00 1+00.00 1+50.00 1+60.57 1+89.18 2+00 2+50.00 2+63.13 2+75 881.84879.502+00 881.53881.73STORM STR. 612INV(E):880.8453 LF OF 12" RCP @ 0.30%STORM STR. 611INV(W):880.68STORM STR 621INV(E):880.25RIM:882.24STORM STR. 620INV(W):880.0012 LF OF 12" HDPE N12 @ 2.04% 51 LF OF 6" HDPE @ 0.00% STORM STR 602INV(N):878.00INV(W):878.00RIM:881.3029 LF OF 12" HDPE N12 @ 0.52%STORM STR 601INV(S):877.85INV(N):877.85RIM:881.5074 LF OF 12" RCP @ 0.34%STORM STR 600INV(S):877.60RIM:882.0018" MIN.+87.23 EL:874.1± EX. 10" SANITARY +33.70 EL:876.9± EX. WATER CONC. CRADLE REQ'D PR STORM PROFILE STR. 631- 630 870 875 880 885 890 895 900 -0+10 0+00 0+00.00 0+50 PR STORM PROFILE STR. 641-640 870 875 880 885 890 895 900 870 875 880 885 890 895 900 -0+10 0+00 0+00.00 0+50STORM STR. 631INV(N):879.65RIM:881.5034 LF OF 12" HDPE @ 0.44%STORM STR 641INV(NW):879.65RIM:881.5034 LF OF 12" HDPE @ 0.44%STORM STR 640INV(SE):879.50RIM:881.30STORM STR 630INV(S):879.50RIM:881.26PROJECT NO. CHECK: DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com PRELI MIN ARY NOT FOR CONST R UCTI O N Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: GENERAL NOTES / LEGEND: SECTION, TOWNSHIP, RANGE: TAKE 5 QUICK LUBE TAKE 5 INDIANA, LLC 10884 GRESHAM PLACE NOBLESVILLE, INDIANA 46060 5/16/2019 1904001 9799 MICHIGAN RD. CARMEL, INDIANA 46032 HAMILTON COUNTY S7, T17N, R3E SHEET NAME SHEET NO. 0 20' 40' SCALE: 1" = 20' N "IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG. C402 STORM PLAN & PROFILE 2. REV. PER CARMEL ENG 10/15/2019 3. REV. PER CARMEL ENG 11/5/2019 AF AF AF AF KG DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. EXISTING RIGHT-OF-WAY NOTE ALL STORM WATER INLETS & CATCH BASIN CASTINGS SHALL BE LABELLED WITH ENVIRONMENTAL MESSAGING "NO DUMPING, DRAINS TO STREAM" CAST IN RAISED OR RECESSED LETTERS AT A MIN. 1-INCH HEIGHT. A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS STORM SEWER INLET NOTE ALL STORM SEWER INFRASTRUCTURE TO BE CONSTRUCTED WITH THE PROJECT LIMITS SHALL BE PRIVATELY OWNED AND MAINTAINED BY OWNER. STORM SEWER SYSTEM NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. EXISTING CONDITIONS NOTE 02/19/20