Loading...
HomeMy WebLinkAboutC401 SITE UTILITY PLAN105 PROPOSED MULTI-TENANT BUILDING 1-STORY, 11,000 GSF DO NOT ENTER DUMPSTER ENCLOSURE///////////////////////////// ////// / / ////////////////////////////////// /////////////////////////////////DO NOTENTERDO NOT E N T E R DO NOTENTERSTOPSTOPPROPO S E D BUILDIN G 1-STORY , 2 , 0 0 0 G S FDUMPSTERENCLOSURE MICHIGAN ROAD (US 421)BENNET T P A R K W A Y (VAR. R / W )REDD ROAD (60 ' R /W )REDD ROAD(50' R/W)BOONE COUNTYHAMILTON COUNTYG 9,522 GSF 81' E 15' D. & U.E.602 601 622 621 611 672 615 614 612 6''SSL 6''SSL 6''SSL GAS METER G G G GAS METER G G GAS METER G G GAS METER G G GAS METER G G G GAS METER G G GGAS METERG G 2''W 2''W 2''W 1-1/2''W UGEUGEUGEUGEUGE UG E UGE UGE UGE UGE UGEUGEUGE631 UD UD UD UDUDUDUD///////////// ///////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////// //////////////// ////////////////// ///// ///// / /// / /////////////// /////DRIVETHRUONLYDRIVETHRUONLYCTSTOPSTOPU G E N 00°30'47" W 654.27'55.02' N 00°37'13" W N 73°44'4 5 " E 1 3 1 . 2 3 'S 16°15'44" E 744.76 ' N 25°44'45" E 23.39' CAPPED REBAR SET CAPPED REBAR SET 15' D.S. & U.E.5' N .A .E .S.& P.H.E . L2 L1L3L5L4 L6 SIGN EASEMENT L1 S 16°15'44" E 38.46' L2 S 73°44'45" W 16.53' L3 S 16°15'15" E 15.00' L4 S 73°44'45" W 20.00' L5 N 16°15'15" W 15.00' L6 N 73°44'45" E 20.00'5' N.A.E .S.& P .H.E . E2 E3 E4 E5 E4 E5 G2 G2 G2 G2 G2 G2 G2 G1 G1 G1 G1 G1 G1 SS1 SS1 SS1 SS1 SS1 SS1 15.3'15.9 ' 84.5'95.4'46.9' 110.5'1 5 . 9 '15.3'SS3 INV.899.4 SS2 INV.900.0 SS2 INV.900.0 SS3 INV.899.7 SS3 INV.898.5 SS3 INV.897.5 SS5 INV.897.0 SS3 INV.898.8 SS2 INV.899.0 SS2 INV.899.0 SS3 INV.897.8 SS6 INV.896.6± FIELD VERIFY LOCATION AND INVERT PRIOR TO CONSTRUCTION FFE:903.10 FFE:903 . 1 0 SS4 SS4 W2 W4 UX UX UX 194 LF OF 1 2 " R C P @ 0 . 3 4 % 21 LF OF 12" RCP @ 0.34% 45 LF OF 12" RCP @ 0.36% 65 LF OF 12" RCP @ 0.46% 19 LF OF 15" RCP @ 0.65%108 LF OF 12" RCP @ 0.40%127 LF OF 15" RCP @ 0.35% 134 L F O F 1 5" R C P @ 0. 4 0 % 28 LF OF 12" RCP @ 0.32% CORE DRILL AND CONNECT NEW STORM PIPE TO EX. STRUCTURE PER CITY OF CARMEL STORMWATER STANDARDS. CORE DRILL AND CONNECT NEW STORM PIPE TO EX. STRUCTURE PER CITY OF CARMEL STORMWATER STANDARDS. ST2 ST2 W2 W3 E6 E6 W3 E3 RELOCATE PRIMARY CONDUIT TO NEW TRANSFORMER FOR SIGN LIGHTING. COORDINATE WITH POWER COMPANY. W1 STORM STRUCTURE DATA TABLE STRUCTURE I.D. 105 601 602 611 612 614 615 621 622 631 672 RIM ELEVATION 899.50 900.09 900.56 900.47 901.01 901.13 901.28 899.31 899.45 899.35 898.50 NEENAH CASTING DESIGNATION ex. beehive R-3286-8V R-3286-8V R-3010 R-3010 R-3286-8V R-3286-8V R-3286-8V R-3286-8V R-4342 ex. beehive INFLOW INV, SIZE, (DIRECTION), [UP STR.] INV:896.04 12" RCP (N)[601] INV:896.21 12" RCP (E)[602] INV:895.27 12" RCP (S)[621] INV:895.06 15" RCP (NE)[612] INV:895.60 12" RCP (NE)[631] INV:896.71 15" RCP (SE)[614] INV:897.57 12" RCP (S)[615] INV:895.67 12" RCP (SE)[622] INV:897.05 6" HDPE (N)[] INV:896.76 6" HDPE (S)[] INV:894.82 15" RCP (E)[611] OUTFLOW INV, SIZE, (DIRECTION), [DOWN STR.] INV:896.00 12" RCP (S)[] INV:896.11 12" RCP (S)[105] INV:896.87 12" RCP (W)[601] INV:894.94 15" RCP (W)[672] INV:895.60 15" RCP (SW)[611] INV:897.15 15" RCP (NW)[612] INV:898.00 12" RCP (N)[614] INV:895.57 12" RCP (N)[611] INV:895.83 12" RCP (NW)[621] INV:895.69 12" RCP (SW)[612] INV:894.59 15" RCP (SW)[] DESCRIPTION & NOTES ex. beehive inlet 2'x2' BOX 2'x2' BOX 48" DIA. MH 48" DIA. MH 2'x2' BOX 2'x2' BOX 2'x2' BOX 2'x2' BOX 2'x2' BOX ex. beehive inlet NOTE: STRUCTURE 613 WAS ELIMINATED. STORM SEWER PIPE DATA TABLE UPSTREAM STRUCTURE I.D. 631 622 621 615 614 612 611 602 601 DOWNSTREAM STRUCTURE I.D. 612 621 611 614 612 611 672 601 105 LENGTH OF PIPE 28 LF 45 LF 65 LF 108 LF 127 LF 134 LF 19 LF 194 LF 21 LF PIPE SIZE / TYPE 12" RCP 12" RCP 12" RCP 12" RCP 15" RCP 15" RCP 15" RCP 12" RCP 12" RCP SLOPE % 0.32% 0.36% 0.46% 0.40% 0.35% 0.40% 0.65% 0.34% 0.34% UPSTREAM PIPE INV. 895.69 895.83 895.57 898.00 897.15 895.60 894.94 896.87 896.11 DOWNSTREAM PIPE INV. 895.60 895.67 895.27 897.57 896.71 895.06 894.82 896.21 896.04 NOTE: STRUCTURE 613 WAS ELIMINATED. PROJECT NO. CHECK:DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com ashton@Fritz-Eng.com Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: PROJECT TEAM: SECTION, TOWNSHIP, RANGE: THE AVENUE AT BENNETT FARM JDF DEVELOPMENT 11710 PEBBLEPOINTE PASS CARMEL, INDIANA 46033 11/18/2020 200905 11100 & 11150 N. MICHIGAN RD. CARMEL, INDIANA 46077 HAMILTON COUNTY SW 1 4, S6, T17N, R3E SHEET NAME SHEET NO. C401 SITE UTILITY PLAN 1. REV PER CARMEL TAC 2/11/2021 2. REV PER TRICO REVIEW 2/19/2021 3. REV STRM SYSTEM 2/24/2021 4. ISSUED FOR BID 2/26/2021 5.REV NORTH DR/PARKING 3/28/2021 6.REV. WATER SERVICE 4/27/2021 AF AF AF AF AF AF AF AF KG 00 30'60' SCALE: 1" = 30' N "IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG. KEY NOTES: E1 ELECTRIC - CONTRACTOR SHALL COORD. EXACT LOCATION, SIZE OF SERVICE WITH MEP PLANS AND POWER CO. E2 ELECTRIC - EX. TRANSFORMER. CONTRACTOR SHALL COORDINATE SERVICE WITH POWER CO. APPROX. LOCATION SHOWN. E3 ELECTRIC - PR. TRANSFORMER. CONTRACTOR SHALL COORDINATE SERVICE WITH POWER CO. APPROX. SIZE/LOCATION SHOWN. E4 ELECTRIC - PR. SECONDARY ELECTRIC SERVICE. COORDINATE CONDUIT AND WIRE WITH MEP PLANS. E5 ELECTRIC - CT CABINET. REF. MEP PLANS FOR EXACT LOCATION AND TENANT DISTRIBUTION/METER LOCAITONS. E6 ELECTRIC - LOOP DETECTORS AT DRIVE THROUGH REQ'D. COORDINATE WITH MEP, TENANT REQUIREMENTS AND OWNER PRIOR TO PAVEMENT CONSTRUCTION. G1 GAS - PROPOSED GAS SERVICE LINE. REF. MEP PLANS FOR SIZE. COORDINATE SERVICE WITH GAS CO. G2 GAS - TENANT GAS METER. REF. MEP PLANS FOR EXACT SIZE AND LOCATION. SS1 SANITARY - 6" PVC SDR 26 LATERAL @ 1.04% MIN., SEE PLAN FOR LENGTH SS2 SANITARY - BUILDING CLEANOUT, TYPE 1 WITH TYPE 2 COVER (WITHIN PAVEMENT), SEE PLAN FOR INVERTS SS3 SANITARY - CLEANOUT, TYPE 2, SEE PLAN FOR INVERTS SS4 SANITARY - 1,000 GALLON GREASE INTERCEPTOR AND SAMPLE STRUCTURE. REF. TRICO DETAILS. SS5 SANITARY - CONNECT PR. SANITARY LATERAL TO EX. MANHOLE PER TRICO STANDARDS. SS6 SANITARY - CONNECT LATERAL TO EX. SANITARY MAIN PER TRICO REGIONAL SEWER STANDARDS. VERIFY MAIN LOCATION AND DEPTH IN FIELD BEFORE CONSTRUCTION. ST1 STORM - PR. STRUCTURE, REF. STORM STRUCTURE TABLE ST2 STORM - 6" PERF. UNDERDRAIN IN SWALE W1 WATER - PR. CORPORATION STOP TAP ON EX. 12" DUCTILE IRON MAIN PER CITIZENS WATER STANDARDS W2 WATER - PR. 1-1/2" DOMESTIC WATER SERVICE LINE WITH 1" METER & PIT. W3 WATER - PR. 2" DOMESTIC WATER SERVICE TAP/LINE. METER & BACKFLOW WITHIN BUILDING. COORDINATE SIZE/LOCATION WITH MEP PLANS. W4 WATER - 8" DUCTILE IRON PIPE WITH CAPS ON EACH END FOR FUTURE FIRE SERVICE AND REMOTE FIRE DEPARTMENT CONNECTION. UX UTILITY CROSSING, APPROX. LOCATION SHOWN. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATION OF ALL EX. UTILITIES WITHIN AREA OF WORK PRIOR TO CONSTRUCTION. ENGINEER SHALL BE NOTIFIED OF ANY POTENTIAL CONFLICTS FOUND. NOTES: 1.UTILITY CROSSINGS UNDER EX. PAVEMENT SHALL BE BORED OR JACK & BORED WHERE POSSIBLE. OPEN CUTS SHALL BE AVOIDED. 2.EXISTING UTILITIES SHOWN HEREON MAY NOT BE A COMPLETE INVENTORY OF ALL EXISTING UTILITIES WITHIN THE AREAS OF CONSTRUCTION. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING UTILITIES WITHIN AND ADJACENT TO THE AREAS OF CONSTRUCTION AND NOTIFY THE OWNER AND ENGINEER OF ANY POTENTIAL CONFLICTS WITH THE PROPOSED IMPROVEMENTS. 6XX XX# DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. EXISTING RIGHT-OF-WAY NOTE ALL STORM WATER INLETS & CATCH BASIN CASTINGS SHALL BE LABELED WITH ENVIRONMENTAL MESSAGING "NO DUMPING, DRAINS TO STREAM" CAST IN RAISED OR RECESSED LETTERS AT A MIN. 1-INCH HEIGHT. A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS STORM SEWER INLET NOTE ALL STORM SEWER INFRASTRUCTURE TO BE CONSTRUCTED WITH THE PROJECT LIMITS SHALL BE PRIVATELY OWNED AND MAINTAINED BY OWNER. STORM SEWER SYSTEM NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. EXISTING CONDITIONS NOTE 1-1/2" WATER SERVICE CONNECTION DETAIL