Loading...
HomeMy WebLinkAboutC402 STORM PLAN & PROFILE105 PROPOSED MULTI-TENANT BUILDING 1-STORY, 11,000 GSF DO NOT ENTER DUMPSTER ENCLOSURE DO NOTENTERSTOP15' BSL MICHIGAN ROAD (US 421)REDD ROAD(50' R/W)BOONE COUNTYHAMILTON COUNTYG 9,522 GSF 81' E15' D. & U.E.602 601 6''SSL G G GAS METER G G GAS METERG G G GAS METERG G GGAS METERG GUGE UGEUGEUGEUG E UG E UGE UGE UGE UGE UGE ///////////// //////////////////////////////////////////////////////////// //////////////////////////////////// //////////// ////DRIVETHRUONLYSTOPN 00°30'47" W 654.27'BOONE COUNTYHAMILTON COUNTYN 00°30'47" W 212.53'CAPPED REBAR SET CAPPED REBAR SET 15' D.S. & U.E.30' GREENBELT & M IN. FRONT SETBACK PER US 421 OVERLAY5' N .A .E.S.& P .H.E .N 00° 30'47" W - 306.35'L=123.34', R=300.00', D=23d33'23"S0°30'47"E 91.86' L:133.62 R:325.00' Δ:23°33'23" N85°00'45"E 237.92'5' N .A .E.S.& P .H .E. FFE:903.10 194 LF OF 12 " R C P @ 0 . 3 4 % 21 LF OF 12" RCP @ 0.34% PROFILE: PR STORM: 602 TO EX 105 890 895 900 905 910 915 890 895 900 905 910 915 1+00.00 1+30.85 1+50.00 2+50.00 3+44.46900.90900.902+00901.80901.80902.13902.133+00901.28901.28STORM STR 602 (2'x2' BOX)WITH R-3286-8VINV(W):896.87 (12" RCP)RIM:900.56194 LF OF 12" RCP @ 0.34%STORM STR 601 (2'x2' BOX)WITH R-3286-8VINV(E):896.21 (12" RCP)INV(S):896.11 (12" RCP)RIM:900.0921 LF OF 12" RCP @ 0.34%STORM STR 105 (ex. beehive inlet)WITH ex. beehiveINV(N):896.04 (12" RCP)INV(S):896.00 (12" RCP)RIM:899.50/////////////////////////////// ////// ////////////////////////////////// /////////////////////////////////DO NOT E N T E R DO NOTENTERSTOP60' BSL 30' BSL & GREENBELTPROPO S E D BUILDIN G 1-STORY , 2 , 0 0 0 G S FDUMPSTERENCLOSUREBENNET T P A R K W A Y (VAR. R / W )REDD ROAD (60 ' R /W ) 622 621 611 672 614 612 6''SSL 6''SSL GAS METER G G G GAS METER1-1/2''WUGEUGE 631 UD UD UD UDUDUDUD////////////////////////////////////////// / / / /// /DRIVETHRUONLYCTSTOPUG E 58.07'L2 L1L3L5L4 L6 S26°15 '17"E 52 .77 ' S0°30'47"E 12.04'S26°15 '15"E 94 .22 ' L:43.64 R:25.00' Δ:99°59'23" S73°44'4 0 " W 1 8 0 . 2 6 ' N61°15'15"W 23.41'N16°15'44"W 436.40'FFE:903 . 1 0 45 LF OF 12" RCP @ 0.36% 65 LF OF 12" RCP @ 0.46% 19 LF OF 15" RCP @ 0.65%108 LF OF 12" RCP @ 0.40%127 LF OF 15" RCP @ 0.35% 134 L F O F 1 5" R C P @ 0. 4 0 % 28 LF OF 12" RCP @ 0.32% PROFILE: PR STORM: 631 TO EX 672 890 895 900 905 910 915 890 895 900 905 910 915 1+00.00 1+28.94 1+50.00 2+50.00 2+63.43 2+99.45901.18901.452+00901.51901.79900.52901.333+00 134 LF OF 15" RCP @ 0.40%STORM STR 611 (48" DIA. MH)WITH R-3010INV(S):895.27 (12" RCP)INV(W):894.94 (15" RCP)INV(NE):895.06 (15" RCP)RIM:900.4719 LF OF 15" RCP @ 0.65%STORM STR 672 (ex. beehive inlet)WITH ex. beehiveINV(E):894.82 (15" RCP)INV(SW):894.59 (15" RCP)RIM:898.50STORM STR 612 (48" DIA. MH)WITH R-3010INV(NE):895.60 (12" RCP)INV(SW):895.60 (15" RCP)INV(SE):896.71 (15" RCP)RIM:901.01STORM STR 631 (2'x2' BOX)WITH R-4342INV(SW):895.69 (12" RCP)INV(N):897.05 (6" HDPE)INV(S):896.76 (6" HDPE)RIM:899.3528 LF OF 12" RCP @ 0.32% PROJECT NO. CHECK:DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com ashton@Fritz-Eng.com Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: PROJECT TEAM: SECTION, TOWNSHIP, RANGE: THE AVENUE AT BENNETT FARM JDF DEVELOPMENT 11710 PEBBLEPOINTE PASS CARMEL, INDIANA 46033 11/18/2020 200905 11100 & 11150 N. MICHIGAN RD. CARMEL, INDIANA 46077 HAMILTON COUNTY SW 1 4, S6, T17N, R3E SHEET NAME SHEET NO. C402 STORM PLAN & PROFILE 1. REV PER CARMEL TAC 2/11/2021 2. REV STRM SYSTEM 2/24/2021 3. ISSUED FOR BID 2/26/2021 4.REV NORTH DR/PARKING 3/28/2021 AF AF AF AF AF AF KG 00 30'60' SCALE: 1" = 30' N "IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. EXISTING RIGHT-OF-WAY NOTE ALL STORM WATER INLETS & CATCH BASIN CASTINGS SHALL BE LABELLED WITH ENVIRONMENTAL MESSAGING "NO DUMPING, DRAINS TO STREAM" CAST IN RAISED OR RECESSED LETTERS AT A MIN. 1-INCH HEIGHT. A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS STORM SEWER INLET NOTE ALL STORM SEWER INFRASTRUCTURE TO BE CONSTRUCTED WITH THE PROJECT LIMITS SHALL BE PRIVATELY OWNED AND MAINTAINED BY OWNER. STORM SEWER SYSTEM NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. EXISTING CONDITIONS NOTE 00 30'60' SCALE: 1" = 30' N LEGEND: FINISHED GRADE EXISTING GRADE GRANULAR BACKFILL (REFERENCE THE CITY OF CARMEL STANDARD DRAWING 10-32) STORM STRUCTURE ID 6XX 0.0 4.0 VERTICALSCALE: 1" = 5'3.0 2.0 1.0 5.0 0.0 4.0 VERTICALSCALE: 1" = 5'3.0 2.0 1.0 5.0 STORM SEWER SYSTEM NOTE THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL.