Loading...
HomeMy WebLinkAboutC403 STORM PLAN & PROFILEPROPOSEDMULTI-TENANTBUILDING1-STORY, 11,000 GSF//////////////////////////////////// / //// //// //// / ///////// ////// / ///////////////////////////DO NOT ENTERSTOP 60' BSL60' F.S.L.30' BSL & G R E E N B E L T PROPOSEDBUILD ING1-STORY, 2,000 GSFBENNETT PARKWAY(VAR. R/W) 615 614 612 6''SSL6''SSLGAS METERGAS METERGGGAS METERGGGAS METERGGGAS METERG2''W2''W2''WUGE631 UDUDUD///////////////////////////////////// //////////////////////////////////////////////////////////////////////////////////////////DRIVETHRUONLYSTOPUGES 16°15'44" E 744.76'L2L1L3L5L4L6SIGN EASEMENTL1S 16°15'44" EL2S 73°44'45" W L3S 16°15'15" EL4S 73°44'45" W L5N 16°15'15" WL6N 73°44'45" E S73°44'40"W 180.26'N61°15'15"W 23.41' N16°15'4 4 " W 4 3 6 . 4 0 'FFE:903.10FFE:903.10108 LF O F 1 2 " R C P @ 0 . 4 0 % 127 LF OF 15" RCP @ 0.35% 1 3 4 L F O F 1 5 " RCP @ 0 . 4 0% 28 LF OF 12" RCP @ 0.32% PROFILE: PR STORM: 615 TO 612 890 895 900 905 910 915 890 895 900 905 910 915 1+00.00 1+50.00 2+18.00 2+50.00 3+50.00 3+53.00901.91901.632+00901.69901.41902.40901.653+00900.54901.92899.74900.93STORM STR 612 (48" DIA. MH)WITH R-3010INV(NE):895.60 (12" RCP)INV(SW):895.60 (15" RCP)INV(SE):896.71 (15" RCP)RIM:901.01127 LF OF 15" RCP @ 0.35%STORM STR 614 (2'x2' BOX)WITH R-3286-8VINV(S):897.57 (12" RCP)INV(NW):897.15 (15" RCP)RIM:901.13108 LF OF 12" RCP @ 0.40%STORM STR 615 (2'x2' BOX)WITH R-3286-8VINV(N):898.00 (12" RCP)RIM:901.28STA: 1+21.5 TOP OF 6" SAN. LATERAL: 897.67± CONCRETE CRADLE REQ'D ///////////////////////////////////////////// //////// / / / //////DO NOT ENTERPROPOSEDBUILDING1-STORY, 2 ,000 GSFDUMPSTERENCLOSUREREDD ROAD(60' R/W)REDD ROAD (50' R/W) BOONE COUNTY HAMILTON COUNTY 622 621 611 672 GAS METERGGGGAS METERGGGGGGGG2''W2''W2''W1-1 /2 ' 'WUGEUGEUGEUGEUDUDUDUD/////////////////////////////DRIVETHRUONLYDRIVETHRUONLYCTL=123.34', R=300.00', D=23d33'23"58.07' L:133.62 R:325.00' Δ:23°33'23"S26°1 5' 1 7 " E 5 2. 7 7' S0°30'47"E 12.04'S26°1 5' 1 5 " E 9 4. 2 2' L:43.64 R:25.00' Δ:99°59'23"S73°44'40"W 180.26'45 LF OF 12" RCP @ 0.36% 65 LF OF 12" RCP @ 0.46% 19 LF OF 15" RCP @ 0.65% 1 3 4 L F O F 1 5 " RCP @ 0 . 4 0% PROFILE: PR STORM: 622 TO 611 890 895 900 905 910 915 890 895 900 905 910 915 1+00.00 1+50.00 1+54.70 2+29.37898.65899.322+00898.95900.8165 LF OF 12" RCP @ 0.46%STORM STR 621 (2'x2' BOX)WITH R-3286-8VINV(SE):895.67 (12" RCP)INV(N):895.57 (12" RCP)RIM:899.3145 LF OF 12" RCP @ 0.36%STORM STR 622 (2'x2' BOX)WITH R-3286-8VINV(NW):895.83 (12" RCP)RIM:899.45STORM STR 611 (48" DIA. MH)WITH R-3010INV(S):895.27 (12" RCP)INV(W):894.94 (15" RCP)INV(NE):895.06 (15" RCP)RIM:900.47PROJECT NO. CHECK:DRAWN: PLAN DATE: DESIGN: STATE OF No. PE10707583 OO14020 Mississinewa Drive Carmel, Indiana 46033 P: 317.324.8695 F: 317.324.8717 www.Fritz-Eng.com ashton@Fritz-Eng.com Fritz Engineering Services, LLC REVISIONS AND ISSUES BYDATE CLIENT: PROJECT: PROJECT LOCATION: PROJECT TEAM: SECTION, TOWNSHIP, RANGE: THE AVENUE AT BENNETT FARM JDF DEVELOPMENT 11710 PEBBLEPOINTE PASS CARMEL, INDIANA 46033 11/18/2020 200905 11100 & 11150 N. MICHIGAN RD. CARMEL, INDIANA 46077 HAMILTON COUNTY SW 1 4, S6, T17N, R3E SHEET NAME SHEET NO. C403 STORM PLAN & PROFILE 1. REV PER CARMEL TAC 2/11/2021 2. REV STRM SYSTEM 2/24/2021 3. ISSUED FOR BID 2/26/2021 4.REV NORTH DR/PARKING 3/28/2021 AF AF AF AF AF AF KG 00 30'60' SCALE: 1" = 30'N"IT'S THE LAW" R Know what's below. Call before you dig. 2 WORKING DAYS BEFORE YOU DIG. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. EXISTING RIGHT-OF-WAY NOTE ALL STORM WATER INLETS & CATCH BASIN CASTINGS SHALL BE LABELLED WITH ENVIRONMENTAL MESSAGING "NO DUMPING, DRAINS TO STREAM" CAST IN RAISED OR RECESSED LETTERS AT A MIN. 1-INCH HEIGHT. A SYMBOL OF A FISH SHALL ALSO BE CAST WITH THE LETTERS STORM SEWER INLET NOTE ALL STORM SEWER INFRASTRUCTURE TO BE CONSTRUCTED WITH THE PROJECT LIMITS SHALL BE PRIVATELY OWNED AND MAINTAINED BY OWNER. STORM SEWER SYSTEM NOTE CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS, INCLUDING UTILITIES AND DRAINAGE INFRASTRUCTURE BEFORE COMMENCING WITH CONSTRUCTION. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIES. EXISTING CONDITIONS NOTE 00 30'60' SCALE: 1" = 30'NLEGEND: FINISHED GRADE EXISTING GRADE GRANULAR BACKFILL (REFERENCE THE CITY OF CARMEL STANDARD DRAWING 10-32) STORM STRUCTURE ID 6XX 0.0 4.0 VERTICALSCALE: 1" = 5'3.0 2.0 1.0 5.0 0.0 4.0 VERTICALSCALE: 1" = 5'3.0 2.0 1.0 5.0 STORM SEWER SYSTEM NOTE THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL.