Loading...
HomeMy WebLinkAboutC050.3 - SANITARY PLAN AND PROFILE 4SEA Group, Land Surveyors SEA Group, Land SurveyorsMH-KM407TRAILBLAZER COURTJASMINE DRIVE ******MH-ETM10MH-ETM09MH-ETM11213 LF - 8 inch SDR-26@ 0.45%283 LF - 8 inch SDR-26@ 0.45%416 LF - 8 inch SDR-26@ 1.84%W W W W W89.326 LF - 6"WYE + LATSTA 1+1690.594 LF - 6"WYE + LATSTA 1+8394.448 LF - 6"WYE + LATSTA 0+3499.646 LF - 6"WYE + LATSTA 1+2215.689 LF - 6"WYE + LATSTA 1+6890 LF - 6"WYE + LATSTA 1+5690 LF - 6"WYE + LATSTA 2+5190 LF - 6"WYE + LATSTA 3+5296 LF - 6"WYE + LATSTA 4+0525 LF - 6"WYE + LATSTA 4+1316 LF - 6"WYE + LATSTA 3+7216 LF - 6"WYE + LATSTA 2+7216 LF - 6"WYE + LATSTA 1+7716 LF - 6"WYE + LATSTA 0+65STA 0+436" SSD. 207 LF 6" SSD. 204 LF6" SSD. 92 LF6" SSD. 294 LF6" SSD. 90 LF6" SSD. 22 LF6" SSD. 210 LF 6" SSD. 51 LF865870875880885890895900 865870875880885890895900MH-ETM10RIM: 895.62IE: 878.74 (N)IE: 878.84 (E)IE: 878.64 (S)MH-ETM11RIM: 894.05IE: 886.50 (W)EXISTING GRADEPROPOSED GRADE15" RCPINV. = 889.95CROWN = 891.39893.8 893.5 893.6 893.9 894.5 895.1 894.0 892.9 892.3 895.62 895.34 895.07 895.13 895.40 895.52 895.27 894.66 894.410+001+002+003+004+00416 LF - 8 inch SDR-26@ 1.84%DRAWING NO.C5.3N:\2018\18414\Drawings\ACAD\LD\S04.1\Sheet Drawings\CD\18414_C5.0 UTILITY PLAN.dwg5/17/2019DESCRIPTIONDATENO. R E V I S I O N S PROJECT NO.: PROJECT MANAGER: DRAWN BY: DESIGNED BY: ORIGINAL ISSUE DATE:18414 DECEMBER 14, 2018 JOR PLD JOR CARMEL INDIANA SANITARY SEWER PLAN & PROFILE ESTATES AT TOWNE MEADOW DESCRIPTIONDATENO. 619 N Pennsylvania St Indianapolis, IN 46204 317.423.0690 phone www.v3co.com Know what'sbelow.before you dig.CallRNOTES:1. CONTRACTOR TO FIELD VERIFY LOCATION, INVERT, AND SIZE OF ALLEXISTING UTILITIES PRIOR TO ORDERING MATERIALS OR BEGINNING UTILITYWORK. CONTRACTOR TO NOTIFY ENGINEER OF ANY DISCREPANCIESIMMEDIATELY.2.UNLESS INDICATED OTHERWISE, FRAME AND OPEN LID STORM STRUCTURESIN PAVEMENT SHALL BE NEENAH R-2502 WITH TYPE D LID OR APPROVEDEQUAL, AND FRAME AND CLOSED LID STORM STRUCTURES IN PAVEMENTSHALL BE NEENAH R-1772 OR APPROVED EQUAL. FRAME AND OPEN LIDSTORM STRUCTURES IN OPEN SPACE SHALL BE R-4340-B OR APPROVEDEQUAL. ALL FRAME AND GRATES SHALL CONFORM TO LOCAL MUNICIPALITYREQUIREMENTS.FRAME AND CLOSED LID STORM STRUCTURES LOCATED WITHIN ANACCESSIBLE ROUTE SHALL BE “NEENAH R-1772 WITH TYPE C LID (OREQUIVALENT) WITH PERMA-GRIP SURFACE. DRILL 1 - 1” DIAMETER LIFT HOLEINSTEAD OF A STANDARD PICK HOLE.”3.LIGHT POLES SHOWN FOR COORDINATION OR LOCATION PURPOSES ONLYAND DO NOT REPRESENT ACTUAL SIZE. SEE PLANS BY SITE LIGHTINGCONSULTANT FOR SITE LIGHTING INFORMATION.KEY MAPN.T.S.