HomeMy WebLinkAboutC060.2 - STORM PLAN AND PROFILE 3TOWNE MEADOW DRIVE**MH-ETM05MH-ETM07MH-ETM06200 LF - 24" RCP @ 0.20%199 LF - 24" RCP @ 0.20%28 LF - 12" RCP @ 1.00%23 LF - 12" RCP @ 1.60%28 LF - 12" RCP @ 2.00%33 LF - 12" RCP @ 0.40%2 X 89 LF - 36" RCP@ 0.56%169 LF - 21" RCP @ 0.20%28 LF - 15" RCP @ 0.58%FH 3FH 5FH 4SSD. RISER892.10SSD. RISER892.186" SSD. 190 LF6" SSD. 188 LFSWALE 148 LF @ 1.01%SWALE 50 LF @ 0.97%SWALE 100 LF @ 1.00%SWALE 100 LF @ 1.00%SWALE 100 LF @ 1.00%SSD. RISER893.076" SSD. 93 LF6" SSD. 296 LFSSD. RISER=891.41INV=890.25SSD. RISER=892.78INV=890.486" SSD. 201 LFSSD. RISER892.00SSD. RISER=891.28INV=888.176" SSD. 143 LFVB 5VB 68 IN X 8 IN-INCH DUCTILE IRON8 IN X 8 IN-INCH DUCTILE IRON8 IN X 8 IN-INCH DUCTILE IRON8 IN X 8 IN-INCH DUCTILE IRON870875880885890895900905870875880885890895900905FES 61924" RCPIE: 887.00 (E)STM 617RIM: 892.00IE: 888.32 (S)IE: 888.11 (W)STM 616T.C. = 892.96IE: 888.86 (S)IE: 888.66 (N)STM 601RIM: 891.01IE: 887.21 (E)IE: 887.11 (W)38 LF - 24" RCP@ 0.30%STM 615T.C. = 892.96IE: 889.02 (N)169 LF - 21" RCP@ 0.20%28 LF - 15" RCP@ 0.58%888.3888.6890.1892.5891.9891.4891.8892.5 893.2 893.4 893.2 892.9 892.6 892.4 887.07891.03891.41891.91892.42892.09892.41892.91 892.59 892.09 893.56 894.32 893.78 892.880+001+002+003+004+005+006+00CROWN = 885.818" PVC SAN. MAININV. = 885.12199 LF - 24" RCP@ 0.20%STM 618RIM: 892.00IE: 887.71 (E)IE: 887.61 (W)200 LF - 24" RCP@ 0.20%50" SUMP ANDSNOUT 24R(SEE DETAIL05/C8.2)BOTTOM OF PIPEINV. = 888.66870875880885890895900905870875880885890895900905STM 621T.C. = 891.48IE: 887.52 (N)IE: 887.42 (SE)23 LF - 12" RCP@ 1.60%FES 62212" RCPIE: 887.06 (NW)889.2 889.0 891.37 890.140+00STM 620RIM: 891.48IE: 887.80 (S)28 LF - 12" RCP@ 1.00%37.5" SUMP ANDSNOUT 18R(SEE DETAIL05/C8.2)875880885890895900905875880885890895900905STM 625T.C. = 892.07IE: 888.36 (N)STM 626T.C. = 892.07IE: 887.80 (S)IE: 887.70 (NE)33 LF - 12" RCP@ 0.40%FES 62712" RCPIE: 887.57 (SW)893.2 891.2 889.7 892.44 892.04 887.000+001+008" WATER MAININV = 884.3528 LF - 12" RCP@ 2.00%37.5" SUMP ANDSNOUT 18R(SEE DETAIL05/C8.2)DRAWING NO.C6.2N:\2018\18414\Drawings\ACAD\LD\S04.1\Sheet Drawings\CD\18414_C5.0 UTILITY PLAN.dwg6/13/2019DESCRIPTIONDATENO. R E V I S I O N S PROJECT NO.: PROJECT MANAGER: DRAWN BY: DESIGNED BY: ORIGINAL ISSUE DATE:18414 DECEMBER 14, 2018 JOR PLD JOR CARMEL INDIANA STORM SEWER PLAN & PROFILE ESTATES AT TOWNE MEADOW DESCRIPTIONDATENO. 619 N Pennsylvania St Indianapolis, IN 46204 317.423.0690 phone www.v3co.com Know what'sbelow.before you dig.CallRKEY MAPN.T.S.NOTES:1. CONTRACTOR TO FIELD VERIFY LOCATION, INVERT,AND SIZE OF ALL EXISTING UTILITIES PRIOR TOORDERING MATERIALS OR BEGINNING UTILITYWORK. CONTRACTOR TO NOTIFY ENGINEER OFANY DISCREPANCIES IMMEDIATELY.2.UNLESS INDICATED OTHERWISE, FRAME AND OPENLID STORM STRUCTURES IN PAVEMENT SHALL BENEENAH R-2502 WITH TYPE D LID OR APPROVEDEQUAL, AND FRAME AND CLOSED LID STORMSTRUCTURES IN PAVEMENT SHALL BE NEENAHR-1772 OR APPROVED EQUAL. FRAME AND OPENLID STORM STRUCTURES IN OPEN SPACE SHALL BER-4340-B OR APPROVED EQUAL. ALL FRAME ANDGRATES SHALL CONFORM TO LOCAL MUNICIPALITYREQUIREMENTS.FRAME AND CLOSED LID STORM STRUCTURESLOCATED WITHIN AN ACCESSIBLE ROUTE SHALL BE“NEENAH R-1772 WITH TYPE C LID (OR EQUIVALENT)WITH PERMA-GRIP SURFACE. DRILL 1 - 1” DIAMETERLIFT HOLE INSTEAD OF A STANDARD PICK HOLE.”3.LIGHT POLES SHOWN FOR COORDINATION ORLOCATION PURPOSES ONLY AND DO NOTREPRESENT ACTUAL SIZE. SEE PLANS BY SITELIGHTING CONSULTANT FOR SITE LIGHTINGINFORMATION.4.THE STORM SEWER SYSTEM SHALL BECONSTRUCTED PER DESIGN SPECIFIED AND ASAPPROVED BY THE CITY OF CARMEL ON THE FINALAPPROVED CONSTRUCTION PLANS. DEVIATIONSFROM THE APPROVED DESIGN SHALL ONLY BEPERMITTED DUE TO SPECIAL CIRCUMSTANCES ORDIFFICULTY DURING CONSTRUCTION AND WILLREQUIRE PRIOR FIELD APPROVAL FROM ADESIGNATED REPRESENTATIVE OF THE CITY OFCARMEL IN ADDITION TO SUPPLEMENTALAPPROVAL BY THE DESIGN ENGINEER. ANEXPLANATION OF ANY SUCH DEVIATION SHALL BEINCLUDED AS A REQUIREMENT ONAS-BUILT/RECORD DRAWINGS SUBMITTED FORRELEASE OF PERFORMANCE GUARANTEES.APPROVED DESIGN SLOPES IDENTIFIED ASGENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10FPS OR GREATER (AT FULL FLOW CAPACITY) SHALLREQUIRE AS-BUILT CERTIFICATION AT THE TIME OFCONSTRUCTION, PRIOR TO BACKFILLING THE PIPE.THE CONTRACTOR IS INSTRUCTED TO AS-BUILTEACH SECTION OF STORM PIPE AS IT IS BEINGINSTALLED TO ENSURE COMPLIANCE WITH THEDESIGN PLANS AND AS APPROVED BY THE CITY OFCARMEL..