HomeMy WebLinkAboutC060.4 - STORM PLAN AND PROFILE 5TRAILBLAZER COURTJASMINE DRIVE ******MH-ETM10MH-ETM09MH-ETM1128 LF - 12" RCP @ 0.50%138 LF - 15" RCP @ 0.60%328 LF - 15" RCP @ 0.80%28 LF - 12" RCP @ 0.40%154 LF - 15" RCP @ 0.25%SSD. RISER894.63SSD. RISER894.07SSD. RISER892.086" SSD. 92 LF6" SSD. 294 LF6" SSD. 90 LF6" SSD. 22 LFSWALE 124 LF @ 1.00%SWALE 300 LF @ 1.00%SWALE 100 LF @ 1.00%141 LF - 21" RCP @ 0.59%865870875880885890895900905910865870875880885890895900905910STM 632T.C. = 894.56IE: 890.84 (E)28 LF - 12" RCP@ 0.50%STM 633T.C. = 894.56IE: 890.70 (W)IE: 890.60 (E)138 LF - 15" RCP@ 0.60%STM 634RIM: 893.70IE: 889.77 (W)IE: 889.62 (S)IE: 889.57 (E)FES 65021" RCPIE: 886.00 (W)895.2894.6894.2893.3892.7893.2893.3894.1
894.2
893.7
892.8
892.0
891.6
890.4
895.06894.57894.54894.04893.87894.68893.13892.63
892.13
891.63
891.13
891.38
891.88
888.010+001+002+003+004+005+006+008" PVC SAN. MAININV. = 879.33CROWN = 880.02328 LF - 15" RCP@ 0.80%STM 635RIM: 891.00IE: 886.93 (W)IE: 886.82 (E)141 LF - 21" RCP@ 0.60%37.5" SUMP ANDSNOUT 18R(SEE DETAIL05/C8.2)865870875880885890895900905910865870875880885890895900905910154 LF - 15" RCP@ 0.25%STM 634RIM: 893.70IE: 889.77 (W)IE: 889.62 (S)IE: 889.57 (E)893.7
893.7
893.6
893.1
894.15
894.15
896.01
895.110+001+00CROWN = 881.668" PVC SAN. MAININV. = 880.9728 LF - 12" RCP@ 0.40%STM 638TC = 894.20IE: 890.27 (N)STM 639TC = 894.20IE: 890.16 (S)IE: 890.01 (N)37.5" SUMP ANDSNOUT 18R(SEE DETAIL05/C8.2)87087588088589089590090587087588088589089590090521 LF - 12" RCP@ 2.00%STM 636RIM: 891.80IE: 888.02 (NE)890.1
890.6
891.95
885.630+00FES 63712" RCPIE: 887.6037.5" SUMP ANDSNOUT 18R(SEE DETAIL05/C8.2)DRAWING NO.C6.4N:\2018\18414\Drawings\ACAD\LD\S04.1\Sheet Drawings\CD\18414_C5.0 UTILITY PLAN.dwg5/17/2019DESCRIPTIONDATENO.
R E V I S I O N S
PROJECT NO.:
PROJECT MANAGER:
DRAWN BY:
DESIGNED BY:
ORIGINAL ISSUE DATE:18414 DECEMBER 14, 2018
JOR
PLD
JOR
CARMEL INDIANA
STORM SEWER PLAN & PROFILE
ESTATES AT TOWNE MEADOW
DESCRIPTIONDATENO.
619 N Pennsylvania St
Indianapolis, IN 46204
317.423.0690 phone
www.v3co.com
Know what'sbelow.before you dig.CallRKEY MAPN.T.S.NOTES:1. CONTRACTOR TO FIELD VERIFY LOCATION, INVERT,AND SIZE OF ALL EXISTING UTILITIES PRIOR TOORDERING MATERIALS OR BEGINNING UTILITYWORK. CONTRACTOR TO NOTIFY ENGINEER OFANY DISCREPANCIES IMMEDIATELY.2.UNLESS INDICATED OTHERWISE, FRAME AND OPENLID STORM STRUCTURES IN PAVEMENT SHALL BENEENAH R-2502 WITH TYPE D LID OR APPROVEDEQUAL, AND FRAME AND CLOSED LID STORMSTRUCTURES IN PAVEMENT SHALL BE NEENAHR-1772 OR APPROVED EQUAL. FRAME AND OPENLID STORM STRUCTURES IN OPEN SPACE SHALL BER-4340-B OR APPROVED EQUAL. ALL FRAME ANDGRATES SHALL CONFORM TO LOCAL MUNICIPALITYREQUIREMENTS.FRAME AND CLOSED LID STORM STRUCTURESLOCATED WITHIN AN ACCESSIBLE ROUTE SHALL BE“NEENAH R-1772 WITH TYPE C LID (OR EQUIVALENT)WITH PERMA-GRIP SURFACE. DRILL 1 - 1” DIAMETERLIFT HOLE INSTEAD OF A STANDARD PICK HOLE.”3.LIGHT POLES SHOWN FOR COORDINATION ORLOCATION PURPOSES ONLY AND DO NOTREPRESENT ACTUAL SIZE. SEE PLANS BY SITELIGHTING CONSULTANT FOR SITE LIGHTINGINFORMATION.4.THE STORM SEWER SYSTEM SHALL BECONSTRUCTED PER DESIGN SPECIFIED AND ASAPPROVED BY THE CITY OF CARMEL ON THE FINALAPPROVED CONSTRUCTION PLANS. DEVIATIONSFROM THE APPROVED DESIGN SHALL ONLY BEPERMITTED DUE TO SPECIAL CIRCUMSTANCES ORDIFFICULTY DURING CONSTRUCTION AND WILLREQUIRE PRIOR FIELD APPROVAL FROM ADESIGNATED REPRESENTATIVE OF THE CITY OFCARMEL IN ADDITION TO SUPPLEMENTALAPPROVAL BY THE DESIGN ENGINEER. ANEXPLANATION OF ANY SUCH DEVIATION SHALL BEINCLUDED AS A REQUIREMENT ONAS-BUILT/RECORD DRAWINGS SUBMITTED FORRELEASE OF PERFORMANCE GUARANTEES.APPROVED DESIGN SLOPES IDENTIFIED ASGENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10FPS OR GREATER (AT FULL FLOW CAPACITY) SHALLREQUIRE AS-BUILT CERTIFICATION AT THE TIME OFCONSTRUCTION, PRIOR TO BACKFILLING THE PIPE.THE CONTRACTOR IS INSTRUCTED TO AS-BUILTEACH SECTION OF STORM PIPE AS IT IS BEINGINSTALLED TO ENSURE COMPLIANCE WITH THEDESIGN PLANS AND AS APPROVED BY THE CITY OFCARMEL..