Loading...
HomeMy WebLinkAboutC800 Details-C804NOTE: THAT ALL CONCRETE AND BITUMINOUS MATERIAL PRODUCTION, TRANSPORT AND DELIVERY, PAVING AND PLACEMENT OPERATIONS FOR IMPROVEMENTS LOCATED WITHIN EXISTING OR FUTURE CITY OF CARMEL RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE INDOT STANDARD AND SUPPLEMENTAL SPECIFICATIONS, LATEST EDITION. TRANSVERSE CONTRACTION JOINTS TOP OF CURB CURB JOINT DETAIL MAX. 50' TRANSVERSE EXPANSION JOINTS PAVEMENT ***** ***** BOTTOM OF CURB WHEN BUILT IN CONJUCTION WITH CONCRETE PAVEMENT, EXPANSION AND CONTRACTION JOINTS SHALL BE PLACED AT THE SAME LOCATIONS AS IN THE PAVEMENT SLABS. THE CURB AND GUTTER SHALL BE TIED TO THE PAVEMENT BY 1/2" ROUND DEFORMED BARS AT ABOUT 3 FOOT INTERVALS. IF NO CONCRETE PAVEMENT IS BEING BUILT AT THE TIME THE CURB IS CONSTRUCTED, EXPANSION JOINTS SHALL BE PLACED AT THE ENDS OF ALL RETURNS AND AT INTERVALS NOT TO EXCEED 50 FEET. CONTRACTION JOINTS ON TANGENT SECTIONS SHALL BE INSTALLED AT 10 FOOT MAX. SPACING. CONTRACTION JOINTS ON RADII SHALL BE INSTALLED AT 5 FOOT MAX. SPACING. MAX. 50'***** MINIMUM COVER FOR PIPE CROSSINGS OF CITY STREETS: THE MINIMUM COVER FROM THE TOP OF THE INSTALLED PAVEMENT TO THE TOP OF THE TINSTALLED PIPE SHALL BE THE PAVEMENT SECTION, THICKNESS (ALL BITUMINOUS AND AGGREGATE MATERIAL ABOVE THE SUBGRADE) PLUS 1'-0", BUT UNDER NO CIRCUMSTANCES SHALL THE COVER ALONG ANY PART OF THE PIPE FROM THE FINAL PAVEMENT ELEVATION TO THE TOP OF THE PIPE BE LESS THAN 2.5 FEET. * NOTE: ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED CITY RIGHT-OF-WAY. *NOTE TO CONTRACTOR: THE CITY OF CARMEL AND THE HAMILTON COUNTY SURVEYOR'S OFFICE REQUIRE DOUBLE WALL HANCOR HI-Q SSD PIPE OR EQUAL TO BE USED. SIDEWALK NOTE: 1. ALL TRANSVERSE JOINTS SHALL BE TOOLED OR SAWCUT JOINTS 1/4 THE THICKNESS OF THE CONCRETE SIDEWALK. 2. WALKS ACROSS DRIVEWAYS SHALL BE 6" OR THE THICKNESS OF THE PROPOSED DRIVEWAY WHICHEVER IS THICKER. 24'-0" (PRIVATE - BLOCK A) * COMPACTED SUBGRADE THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT ALL STATE HIGHWAYS, CITY, AND COUNTY PERMITS HAVE BEEN OBTAINED BY THE DEVELOPER PRIOR TO START OF CONSTRUCTION.DATEMARKREVISIONSBYCERTIFIED:S & A JOB NO. SHEET NO. DRAWN BY:CHECKED BY:S T O E P P E L W E R T HA L W A Y S O N7965 East 106th Street, Fishers, IN 46038-2505phone: 317.849.5935 fax: 317.849.5942STREET DETAILSC804 DOUBLE WALL PIPE, HANCOR Hi-Q, TYPE 4 PIPE OR EQUIVALENT PER SECTION 401.01 OF THE STORM WATER TECHNICAL STANDARDS SEE TYPICAL STREET SECTIONS BELOW ALL PAVING IS TO BE COMPLETED IN ONE PAVING SEASON 60160HAM-S2THE HAMLET at JACKSONS GRANTADG BAH CARMELHAMILTON COUNTY, INDIANA01/16/19DP IT E S G E E O TS R P RTE WLE D E HVADIRJ .ADNINAI EEG NIRENOILA NS FEPRO STATE OF S SECTION 2File Name:S:\60160HAM-S2\DWG\C800 Details.dwg - C804Modified / By:March 11, 2019 6:51:28 PM / jwillisPlotted / By:July 1, 2019 2:13:01 PM / Kenny Mitchell03/12/19JAWREVISED PER TAC COMMENTSAPPROVAL PENDING - NOT FOR CONSTRUCTION07/01/19KJJMMOVED SANITARY STRUCTURE #JGH2022'-0" ASPHALT SHOULDER MIN. 3" TOPSOIL SLOPE: 1/4" / FT. MIN. 3" TOPSOIL SLOPE: 1/4" / FT. 2'-0" ASPHALT SHOULDER 20'-0" NOT-TO-SCALE TYPICAL ROAD CROSS-SECTION SIGILLARY LANE 22'-0" (PRIVATE - BLOCK A) * COMPACTED SUBGRADE DOUBLE WALL PIPE, HANCOR Hi-Q, TYPE 4 PIPE OR EQUIVALENT PER SECTION 401.01 OF THE STORM WATER TECHNICAL STANDARDS 2'-0" ASPHALT SHOULDER MIN. 3" TOPSOIL SLOPE: 1/4" / FT. MIN. 3" TOPSOIL SLOPE: 1/4" / FT. 2'-0" ASPHALT SHOULDER 18'-0" NOT-TO-SCALE TYPICAL ROAD CROSS-SECTION RAYLE DRIVE 10"24" CLASS A CONCRETE 6-3/4"18" RADIUS3" TOP SOIL COMPACTED BACKFILL NOTES: INTEGEGRAL CURB WITH CONCRETE PAVEMENT SHALL BE SIMILAR SHAPE CURVE ALL EXPOSED SURFACES DAMPEN SUBGRADE BEFORE PLACING CONCRETE CONTROL JOINTS EVERY 5' ON RADII OTHERWISE EVERY 10' MAXIMUM. PREFORMED EXPANSION JOINT EVERY 50' MAXIMUM. NO BACKFILLING OR COMPACTION MAY OCCUR 12' FROM CURB UNTIL 5 FULL DAYS HAVE PASSED AFTER PLACING CONCRETE SHALL CONFORM TO CITY'S CONCRETE CURB POLICY IN ALL RESPECTS CONCRETE ROLL CURB & GUTTER NOT-TO-SCALE (REVERSE LIP) GUTTER TO FORMED TO ENSURE DRAINAGE AWAY FROM CURB FLOW SEE CARMEL STANDARD PVMT CROSS SECTION ABOVE SEE CARMEL STANDARD PVMT CROSS SECTION ABOVE MONOLETHIC CURB AND WALK CURB & WALK DETAIL NO SCALE SEE PLANS OF TOTAL THICKNESS OF SLAB @ 6-0" MAX. REBAR AND WELDED WIRE FABRIC SHOULD BE STOPPED 2" SHORT OF AN EXPANSION JOINT. @ 48'-0" MAX. AND @ ENDS OF RADII. SHALL HAVE 1/2" EXPANSION JOINTS CONSTRUCTION JOINTS SHALL BE CUT 1/4 DEPTH18"REBAR 3"2 - #4 NOTES: 6"1. 2. 3. 45° 3" 6" 2" RAD.3"6"CLR.CONTROL JOINT 6" AGGREGATE SIZE #53 4" OF COMPACTED 6x6 W1.4xW1.4xW.W.F. 1 1/2"4"AS INDICATED ON THE DRAWINGS. PROVIDE A EXPANSION JOINT AT INTERSECTION WITH ANOTHER SIDEWALK, BETWEEN WALKS, BUILDINGS, 5. STORM STRUCTURES, AND AT SUCH OTHER POINTS EACH FINISHING OPERATON. 4. OF SIDEWALKS SHOULD BE HAND-TOOLED AFTER CONTROL JOINTS, EXPANSION JOINTS AND EDGES4" PAVEMENT 4" AGGREGATE SIZE #53 4" OF COMPACTED 1" PREFORMED JOINT FILLER WITH SEALER. NOT-TO-SCALE EXTEND JT. MATERIAL TO BOTTOM OF PVMT. 1/2" PREFORMED WATERPROOF EXPANSION JOINT 1/2" PROTECTION EXPANSION JT. CONC. PVMT. BOARD MEMBRANE SELF LEVELING SEALANT BUILDING FACE BACKER ROD SUBGRADE NOT-TO-SCALE ~4" MAX. ~4" MAXIMUM ~2" MINIMUM EDGE RADIUS = SPECIFICATIONS SEAL JOINT PER HAND-TOOLED JOINT, CONTINUOUS SAWED OR EDGE OF CONCRETE. SAWCUT JOINT AS SOON AS POSSIBLE WITHOUT RAVELING THE 2" CLEAR2" CLEAR SLAB REINFORCING TYPICAL CONTROL JOINT NOTE: 1. 4" D/4 D/3 2" OF CRUSHED STONE OR SAND CONTROL JOINTS SHALL BE PLACED EVERY 5FT ON CENTER NOT-TO-SCALE SEE STREET DIMENSIONS BELOW