HomeMy WebLinkAboutThe Proscenium II Full SetVANVANCOMPACT EXECUTIVE DRIVESOUTH RANGELINE ROADPROPOSED BUILDINGPROPOSED BUILDINGPROPOSED GARAGE REVISIONDATE No. SITE PLAN VICINITY MAP SHEET INDEX PROJECT No.: PROSCENIUM PHASE II (1215) EXECUTIVE DRIVE AND SOUTH RANGELINE ROAD CARMEL, INDIANA OCTOBER 26, 2021 NOVO DEVELOPMENT GROUP 20 W CARMEL DRIVE, SUITE 101 CARMEL, IN 46032 C000 333 North Alabama Street Suite 200 Indianapolis, IN 46204 317.299.7500 FAX: 317.291.5805 SITE brian.smallwood@woolpert.com thill@novo.dev (317) 343-9757 09/14/22 GENERAL NOTES 1. EXISTING CONDITIONS AS DEPICTED ON THESE PLANS ARE GENERAL AND ILLUSTRATIVE IN NATURE. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO EXAMINE THE SITE AND BE FAMILIAR WITH EXISTING CONDITIONS PRIOR TO BIDDING ON THIS PROJECT. IF CONDITIONS ENCOUNTERED DURING EXAMINATION ARE SIGNIFICANTLY DIFFERENT FROM THOSE SHOWN, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT/ENGINEER/CONSTRUCTION MANAGER IMMEDIATELY. 2. EXISTING SITE INFORMATION AND TOPOGRAPHIC SURVEY WAS PREPARED BY WOOLPERT INC., DATED MAY 28, 2021. ANY SITE CHANGES/MODIFICATIONS MADE AFTER THIS SURVEY ARE NOT REFLECTED IN THESE PLANS. CONTRACTOR TO NOTIFY WOOLPERT, INC. OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH CONSTRUCTION. ITEMS INDICATED AS PER RECORDS AND OUTSIDE THE SURVEY LIMITS ARE BASED ON VARIOUS RECORD DRAWINGS PROVIDED BY THE OWNER, WOOLPERT IS NOT RESPONSIBLE FOR THE ACCURACY OR COMPLETENESS OF THE INFORMATION SHOWN. 3. THE CONTRACTOR SHALL VERIFY THE LOCATIONS AND ELEVATIONS OF ALL EXISTING UTILITIES (INCLUDING THOSE LABELED PER RECORDS) PRIOR TO THE BEGINNING OF CONSTRUCTION OR EARTH MOVING OPERATIONS. INFORM ARCHITECT/ENGINEER/CONSTRUCTION MANAGER OF ANY CONFLICTS DETRIMENTAL TO THE DESIGN INTENT. 4. 48 HOURS PRIOR TO COMMENCEMENT OF DIGGING, CONTRACTOR SHALL NOTIFY THE FOLLOWING AGENCIES: THE INDIANA UTILITY PROTECTION SERVICES 811, AND ALL OTHER AGENCIES THAT MAY HAVE UNDERGROUND UTILITIES WITHIN THE PROJECT LIMITS AND ARE NON-MEMBERS OF INDIANA UNDERGROUND PROTECTION SERVICES. 5. THE CONTRACTOR AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR COMPLYING WITH APPLICABLE FEDERAL, STATE AND LOCAL REQUIREMENTS, TOGETHER WITH EXERCISING PRECAUTIONS AT ALL TIMES FOR THE PROTECTION OF PERSONS (INCLUDING EMPLOYEES) AND PROPERTY. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SUBCONTRACTORS TO INITIATE, MAINTAIN AND SUPERVISE ALL SAFETY REQUIREMENTS, PRECAUTIONS, AND PROGRAMS IN CONNECTION WITH THE WORK. 6. THE CONTRACTOR SHALL INDEMNIFY AND HOLD HARMLESS THE OWNER AND OWNER'S REPRESENTATIVE FOR ANY AND ALL INJURIES AND/OR DAMAGES TO PERSONNEL, EQUIPMENT AND/OR EXISTING FACILITIES OCCURRING IN THE COURSE OF THE DEMOLITION AND CONSTRUCTION DESCRIBED IN THE PLANS AND SPECIFICATIONS. 7. CONTRACTOR SHALL OBTAIN A PERMIT FOR ALL CONSTRUCTION ACTIVITIES IN ACCORDANCE WITH LOCAL, STATE, & FEDERAL REGULATIONS. 8. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL CODES, OBTAIN ALL APPLICABLE PERMITS, AND PAY ALL REQUIRED FEES PRIOR TO COMMENCING WORK. 9. ANY WORK PERFORMED IN CARMEL, INDIANA RIGHT OF WAYS SHALL BE IN ACCORDANCE WITH THE APPLICABLE CITY OF CARMEL, INDIANA REQUIREMENTS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN THE NECESSARY PERMITS FOR THE WORK, SCHEDULE NECESSARY INSPECTIONS, AND PROVIDE THE NECESSARY TRAFFIC CONTROL MEASURES AND DEVICES, ETC., FOR WORK PERFORMED IN THE RIGHT OF WAYS. 10. THE CONTRACTOR IS TO PERFORM ALL INSPECTIONS AS REQUIRED BY THE INDIANA DEPARTMENT FOR ENVIRONMENTAL MANAGEMENT (IDEM) FOR THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM (NPDES) PERMIT AND FURNISH OWNERS REPRESENTATIVE WITH WRITTEN REPORTS. OWNER WILL OBTAIN NPDES PERMIT. 11. CONTRACTOR SHALL IMPLEMENT ALL SOIL AND EROSION CONTROL, PRACTICES REQUIRED BY THE CITY OF CARMEL AND THE IDEM. 12. ALL GROUND SURFACE AREAS THAT HAVE BEEN EXPOSED OR LEFT BARE AS A RESULT OF CONSTRUCTION AND ARE TO FINAL GRADE AND ARE TO REMAIN SO, SHALL BE SEEDED AND MULCHED AS SOON AS PRACTICAL IN ACCORDANCE WITH SPECIFICATIONS. IF NO SPECIFICATIONS ARE SUPPLIED, USE INDOT SPECIFICATION ITEM 205.04. 13. ITEM NUMBERS REFER TO THE 2022 INDOT STANDARD SPECIFICATIONS, AND ALL CONSTRUCTION WORK SHALL BE DONE ACCORDING TO SAID SPECIFICATIONS AND IN ACCORDANCE WITH APPLICABLE STANDARDS OF THE CITY OF CARMEL. WHEN IN CONFLICT, THE CITY REQUIREMENTS SHALL PREVAIL. 14. ALL WORK PERFORMED BY THE CONTRACTOR SHALL CONFORM TO THE LATEST REGULATIONS OF THE AMERICANS WITH DISABILITIES ACT. 15. THE CONTRACTOR SHALL REFER TO OTHER PLANS WITHIN THIS CONSTRUCTION SET FOR OTHER PERTINENT INFORMATION. IT IS NOT THE ENGINEER'S INTENT THAT ANY SINGLE PLAN SHEET IN THIS SET OF DOCUMENTS FULLY DEPICT ALL WORK ASSOCIATED WITH THE PROJECT. 16. BEFORE INSTALLATION OF STORM SEWER, SANITARY SEWER, ELECTRICAL CONDUIT, WATERLINE OR ANY OTHER UTILITY, THE CONTRACTOR SHALL VERIFY ALL CROSSINGS, BY EXCAVATION WHERE NECESSARY, AND INFORM THE OWNER AND THE ARCHITECT/ENGINEER/CONSTRUCTION MANAGER OF ANY CONFLICTS. THE DESIGN ENGINEER WILL BE HELD HARMLESS IF NOT NOTIFIED OF DESIGN CONFLICTS PRIOR TO CONSTRUCTION. 17. ADJUST OR RECONSTRUCT ALL EXISTING CASTINGS, CLEANOUTS, ETC. WITHIN PROJECT AREA TO MEET PROPOSED GRADE AS REQUIRED. 18. CONTRACTOR TO REMOVE & REPLACE PAVEMENT AS SPECIFIED. 19. THE CONTRACTOR SHALL CHECK EXISTING GRADES, DIMENSIONS, AND INVERTS IN THE FIELD AND REPORT ANY DISCREPANCIES TO THE OWNER'S REPRESENTATIVE PRIOR TO BEGINNING WORK. 20. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL EXISTING UTILITIES. TAKE CARE TO PROTECT UTILITIES THAT ARE TO REMAIN. RELOCATE EXISTING UTILITIES AS INDICATED, OR AS NECESSARY FOR CONSTRUCTION. 21. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO COMMENCEMENT OF CONSTRUCTION. 22. PROVIDE A SMOOTH TRANSITION BETWEEN EXISTING PAVEMENT AND NEW PAVEMENT. FIELD ADJUSTMENT OF FINAL GRADES MAY BE NECESSARY. INSTALL ALL UTILITIES PRIOR TO INSTALLATION OF PAVED SURFACES. 23. SITE WORK CONCRETE WALKS AND PADS SHALL HAVE A BROOM FINISH TO ALL SURFACES. SITE WORK CONCRETE SHALL BE CLASS A (4,000 PSI @ 28 DAYS) UNLESS OTHERWISE NOTED. 24. ALL DAMAGE TO EXISTING PAVEMENT, SIDEWALK, CURB, LANDSCAPING, UTILITIES, AND ANY OTHER ITEMS TO REMAIN, WHICH RESULTS FROM THE CONTRACTOR'S OPERATIONS SHALL BE REPLACED WITH LIKE MATERIALS AT THE CONTRACTOR'S EXPENSE. 25. SITE DIMENSIONS SHOWN ARE TO THE BACK OF CURB, BUILDING, WALL, EDGE OF PAVEMENT, OR COLUMN LINE UNLESS OTHERWISE NOTED. 26. COORDINATES ARE FOR BUILDING COLUMNS, EXTERIOR BUILDING WALLS, CENTERS OF DRIVEWAYS, CENTER OF SANITARY SEWER MANHOLES, AND CENTER OF STRUCTURES PLACED SIX INCHES INSIDE FACE OF CURB FOR DRAIN INLETS, UNLESS OTHERWISE NOTED. 27. CONTRACTOR SHALL MAINTAIN ONE SET OF AS-BUILT/RECORD DRAWINGS ON-SITE DURING CONSTRUCTION FOR DISTRIBUTION TO THE OWNER AND/OR OWNER'S REPRESENTATIVE UPON COMPLETION. 28. REFER TO THE ARCHITECTURAL, PLUMBING & ELECTRICAL DRAWINGS FOR EXACT DIMENSIONS AND LOCATIONS OF UTILITY SERVICE ENTRY LOCATIONS AND PRECISE BUILDING DIMENSIONS. 29. THIS SITE LAYOUT IS SPECIFIC TO THE APPROVALS NECESSARY FOR THE CONSTRUCTION IN ACCORDANCE WITH THE CITY OF CARMEL. NO CHANGES TO THE SITE LAYOUT ARE ALLOWED WITHOUT THE WRITTEN APPROVAL OF THE ENGINEER. CHANGES MADE TO THE SITE LAYOUT WITHOUT APPROVAL IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR. CHANGES INCLUDE BUT ARE NOT LIMITED TO, INCREASED IMPERVIOUS PAVEMENT, ADDITION/DELETION OF PARKING SPACES, MOVEMENT OF CURB LINES, CHANGES TO DRAINAGE STRUCTURES AND PATTERNS, LANDSCAPING, ETC. 30. SITE SIGNAGE AND STRIPING SHALL BE IN ACCORDANCE WITH THE KENTUCKY MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES. 31. CONCRETE WALKS SHALL BE 4" THICK OVER PREPARED SUBGRADE COMPACTED IN ACCORDANCE WITH SECTION 207.02 OF STANDARD INDOT SPECS. SEE CITY OF CARMEL STANDARD DETAIL 10-14 ON SHEET C500. DEMOLITION NOTES 1. ALL EXISTING ABOVE AND BELOW GROUND STRUCTURES WITHIN THE LIMITS OF CONSTRUCTION SHALL BE REMOVED UNLESS NOTED OTHERWISE SPECIFIED WITHIN THIS CONSTRUCTION SET AND/OR PROJECT MANUAL. THIS INCLUDES WALLS AND FOOTINGS. CAVITIES LEFT BY STRUCTURE REMOVAL SHALL BE BACKFILLED WITH SATISFACTORY MATERIALS AND COMPACTED TO THE GEOTECHNICAL ENGINEER'S RECOMMENDATION. 2. CLEARING LIMITS SHALL BE PHYSICALLY MARKED IN THE FIELD BY THE CONTRACTOR. 3. NO TREES SHALL BE REMOVED, NOR VEGETATION DISTURBED BEYOND THE LIMITS OF CONSTRUCTION WITHOUT THE EXPRESS WRITTEN APPROVAL OF THE OWNER'S REPRESENTATIVE. 4. TREE PROTECTION FENCING SHALL BE IN ACCORDANCE WITH THE CITY OF CARMEL STANDARDS - OR - IN ACCORDANCE WITH THE DETAILED DRAWINGS. DO NOT OPERATE OR STORE EQUIPMENT, NOR HANDLE OR STORE MATERIALS WITHIN THE DRIP LINES OF THE TREES SHOWN TO REMAIN. 5. PROTECTION OF EXISTING TREES AND VEGETATION: PROTECT EXISTING TREES AND OTHER VEGETATION INDICATED TO REMAIN IN PLACE AGAINST UNNECESSARY CUTTING, BREAKING OR SKINNING OF ROOTS, SKINNING OR BRUISING OF BARK, SMOTHERING OF TREES BY STOCKPILING CONSTRUCTION MATERIALS OR EXCAVATED MATERIALS WITHIN DRIP LINE, EXCESS FOOT OR VEHICULAR TRAFFIC, OR PARKING OF VEHICLES WITHIN DRIP LINE. PROVIDE TEMPORARY GUARDS TO PROTECT TREES AND VEGETATION TO BE LEFT STANDING. 6. ALL DEMOLITION WASTE AND CONSTRUCTION DEBRIS SHALL BECOME THE PROPERTY OF THE CONTRACTOR UNLESS OTHERWISE DESIGNATED. ALL DEBRIS SHALL BE REMOVED BY THE CONTRACTOR AND DISPOSED OF OFFSITE IN A STATE APPROVED WASTE SITE AND IN ACCORDANCE WITH ALL LOCAL AND STATE CODES AND PERMIT REQUIREMENTS. TAKE CARE TO PROTECT UTILITIES THAT ARE TO REMAIN. REPAIR DAMAGE ACCORDING TO THE APPROPRIATE UTILITY COMPANY STANDARDS AND AT THE CONTRACTOR'S EXPENSE. 7. ALL UTILITY DISCONNECTION, REMOVAL, RELOCATION, CUTTING, CAPPING AND/OR ABANDONMENT SHALL BE COORDINATED WITH THE APPROPRIATE UTILITY COMPANY OR AGENCY. LOCAL UTILITY CONTACTS ARE PROVIDED ON THIS SHEET. 8. THE BURNING OF CLEARED MATERIAL AND DEBRIS SHALL NOT BE ALLOWED UNLESS CONTRACTOR OBTAINS PRIOR LEGAL WRITTEN AUTHORIZATION FROM THE LOCAL AUTHORITIES. 9. EROSION & SEDIMENT CONTROL MEASURES AROUND AREAS OF DEMOLITION SHALL BE PROPERLY INSTALLED AND FUNCTIONING PROPERLY PRIOR TO INITIALIZATION OF DEMOLITION ACTIVITIES. 10. ASBESTOS OR HAZARDOUS MATERIAL ARE NOT EXPECTED. IF FOUND ON SITE, SUCH MATERIALS SHALL BE REMOVED BY A LICENSED HAZARDOUS MATERIALS CONTRACTOR. CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY IF HAZARDOUS MATERIALS ARE ENCOUNTERED. 11. CONTRACTOR SHALL ADHERE TO ALL LOCAL, STATE, FEDERAL AND OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION REGULATIONS DURING ALL DEMOLITION AND CONSTRUCTION ACTIVITIES. 12. CONTRACTOR SHALL PROTECT ALL CORNER PINS, MONUMENTS, PROPERTY CORNERS AND BENCHMARKS DURING DEMOLITION ACTIVITIES. IF DISTURBED, CONTRACTOR SHALL HAVE DISTURBED ITEMS RESET BY A LICENSED SURVEYOR AT NO ADDITIONAL COST TO THE OWNER. 13. CONTRACTOR SHALL PROTECT ALL EXISTING UTILITIES, STRUCTURES, AND FEATURES TO REMAIN. ANY ITEMS TO REMAIN THAT HAVE BEEN DISTURBED OR DAMAGED AS A RESULT OF CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT CONTRACTOR'S EXPENSE. 14. CONTRACTOR SHALL PROVIDE AND MAINTAIN TRAFFIC CONTROL MEASURES IN ACCORDANCE WITH STATE DEPARTMENT OF TRANSPORTATION REGULATIONS, FAA REGULATIONS, AND AS REQUIRED BY LOCAL AGENCIES WHEN WORKING IN AND/OR ALONG STREETS, ROADS, HIGHWAYS, ETC.. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO OBTAIN APPROVAL AND COORDINATE WITH LOCAL AND/OR STATE AGENCIES REGARDING THE NEED, EXTENT AND LIMITATIONS ASSOCIATED WITH INSTALLING AND MAINTAINING TRAFFIC CONTROL MEASURES. 15. PROVIDE STRAIGHT, FULL DEPTH, AND NEAT SAW CUTS OF EXISTING PAVEMENT WHERE INDICATED ALONG LIMITS OF PAVEMENT DEMOLITION. 16. ALL UTILITY AND STRUCTURE REMOVAL, RELOCATION, CUTTING, CAPPING AND/OR ABANDONMENT SHALL BE COORDINATED AND PROPERLY DOCUMENTED BY A CERTIFIED PROFESSIONAL, WHEN APPLICABLE, WITH THE APPROPRIATE UTILITY COMPANY, MUNICIPALITY AND/OR AGENCY. DEMOLITION OF REGULATED ITEMS MAY INCLUDE, BUT NOT LIMITED TO WELLS, ASBESTOS, UNDERGROUND STORAGE TANKS, SEPTIC TANKS AND ELECTRIC TRANSFORMERS. DEMOLITION CONTRACTOR SHALL REFER TO ANY ENVIRONMENTAL STUDIES FOR DEMOLITION RECOMMENDATIONS AND GUIDANCE. AVAILABLE ENVIRONMENTAL STUDIES MAY INCLUDE, BUT ARE NOT LIMITED TO PHASE I ESA, PHASE II ESA, WETLAND AND STREAM DELINEATION AND ASBESTOS SURVEYS. ALL APPLICABLE ENVIRONMENTAL STUDIES SHALL BE MADE AVAILABLE UPON REQUEST. 17. ALL PAVEMENT, BASE COURSES, SIDEWALKS, CURBS, BUILDINGS, FOUNDATIONS, ETC., WITHIN THE AREA THAT ARE INDICATED TO BE DEMOLISHED SHALL BE REMOVED TO FULL DEPTH. EXISTING BASE COURSE MATERIALS MAY BE WORKED INTO THE NEW PAVEMENT OR BUILDING SUBGRADE IF THE GRADATION, CONSISTENCY, COMPACTION, SUBGRADE CONDITION, ETC., ARE IN ACCORDANCE WITH THE SPECIFICATIONS AND RECOMMENDATIONS OF THE GEOTECHNICAL REPORT. BASE COURSE MATERIALS SHALL NOT BE WORKED INTO THE SUBGRADE AREAS TO RECEIVE LANDSCAPING. 18. THE CONTRACTOR SHALL USE SUITABLE METHODS TO CONTROL DUST AND DIRT CAUSED BY THE DEMOLITION ACTIVITIES. SITE EARTHWORK NOTES 1. ALL PROPOSED GRADES SHOWN ARE FINAL GRADES, TOP OF GROUND LEVEL, OR TOP OF PAVEMENT, OR GRATE ELEVATION AT THE DRAWDOWN POINT, UNLESS INDICATED OTHERWISE. 2. REFER TO AND FOLLOW THE RECOMMENDATIONS OF THE GEOTECHNICAL REPORT PREPARED FOR THIS PROJECT BY ALT & WITZIG ENGINEERING, INC. TITLED SUBSURFACE INVESTIGATION & FOUNDATION RECOMMENDATIONS AND DATED NOVEMBER 5, 2021. 3. SITE BUILDING PAD EXCAVATION AND CONSTRUCTION TO BE PER GEOTECHNICAL ENGINEER'S RECOMMENDATIONS (REPORT DATED NOVEMBER 5, 2021). BUILDING PAD PREPARATION SHALL BEGIN BY CLEARING AND REMOVAL OF UNSUITABLE MATERIAL FROM PAD SITE, THEN PLACEMENT AND COMPACTION OF BACKFILL MATERIAL PER GEOTECHNICAL ENGINEER'S RECOMMENDATIONS. 4. ALL FILL UNDER PAVEMENT SHALL BE COMPACTED TO THE GEOTECHNICAL ENGINEER'S RECOMMENDATIONS (REPORT DATED NOVEMBER 5, 2021). 5. ALL ELEVATIONS SHOWN ARE FINISHED GRADE ELEVATIONS. 6. CONTRACTOR SHALL STRICTLY ADHERE TO THE EROSION & SEDIMENT CONTROL PLAN PREPARED FOR THIS PROJECT. 7. EARTHWORK SHALL INCLUDE CLEARING AND GRUBBING, STRIPPING AND STOCKPILING TOPSOIL, MASS GRADING, EXCAVATION, FILLING, UNDERCUT AND REPLACEMENT, IF REQUIRED, AND COMPACTION. 8. CONTRACTOR TO REFILL UNDERCUT AREAS WITH SUITABLE MATERIAL AND COMPACT AS RECOMMENDED BY THE GEOTECHNICAL ENGINEER. 9. PLACE TOPSOIL OVER THE SUBGRADE OF UNPAVED, DISTRIBUTED AREAS TO A DEPTH INDICATED ON THE LANDSCAPE PLANS (4" MINIMUM). 10. PAVEMENT SLOPES ACROSS ACCESSIBLE PARKING STALLS AND ADJOINING ACCESS AISLES SHALL BE MAXIMUM 2% AND SHALL CONFORM TO THE LATEST REGULATIONS OF THE AMERICANS WITH DISABILITIES ACT. 11. ALL AREAS NOT PAVED SHALL BE STABILIZED IN ACCORDANCE WITH THE EROSION & SEDIMENT CONTROL PLAN, UNLESS NOTED OTHERWISE. 12. COMPACTED FILLS ARE TO BE MADE TO A MINIMUM OF THREE FEET ABOVE THE CROWN OF ANY PROPOSED SEWER PRIOR TO CUTTING OF TRENCHES FOR PLACEMENT OF SAID SEWERS. ALL FILLS SHALL BE CONTROLLED, COMPACTED, AND INSPECTED BY AN APPROVED TESTING LABORATORY OR AN INSPECTOR FROM THE APPROPRIATE GOVERNMENTAL AGENCY. 13. ALL EXCESS SOIL MATERIALS SHALL BECOME THE PROPERTY OF THE CONTRACTOR UNLESS OTHERWISE DESIGNATED AND SHALL BE REMOVED BY THE CONTRACTOR AND DISPOSED OF OFFSITE AT NO ADDITIONAL COST TO THE OWNER IN ACCORDANCE WITH ALL LOCAL AND STATE CODES AND PERMIT REQUIREMENTS. 14. THE CONTRACTOR IS RESPONSIBLE FOR BALANCING THE SITE EARTHWORK BY IMPORTING OR EXPORTING AS NECESSARY TO ACHIEVE DESIGN GRADES AND SPECIFICATIONS. STORM DRAINAGE NOTES 1. DISTANCES SHOWN ON PIPING ARE HORIZONTAL DISTANCES FROM CENTER OF STRUCTURE TO CENTER OF STRUCTURE, UNLESS OTHERWISE NOTED, CONTRACTOR RESPONSIBLE FOR ACTUAL FIELD CUT LENGTH. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COSTS ASSOCIATED WITH THE INSTALLATION, INSPECTION, TESTING AND FINAL ACCEPTANCE OF ALL NEW STORMWATER MANAGEMENT FACILITIES CONSTRUCTION. CONTRACTOR SHALL COORDINATE WITH ALL APPLICABLE REGULATING AGENCIES CONCERNING INSTALLATION, INSPECTION AND APPROVAL OF THE STORM DRAINAGE SYSTEM CONSTRUCTION. 3. ALL STORMWATER MANAGEMENT FACILITIES, INCLUDING COLLECTION AND CONVEYANCE STRUCTURES SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE LOCAL AND STATE CODES AND REGULATIONS. 4. ALL CATCH BASINS IN THE PAVEMENT OR CURB ARE TO HAVE A MINIMUM OF ONE, 4" PERFORATED UNDERDRAIN EXTENDING FROM THE CATCH BASIN. 5. ANY FIELD TILE CUT IN EXCAVATION, WHICH DRAINS AN OFFSITE AREA, MUST BE TIED INTO THE STORM DRAINAGE SYSTEM. 6. FOR EXACT LOCATION OF DOWNSPOUTS AND ROOF DRAINS, CONTRACTOR IS TO COORDINATE WITH ARCHITECTURAL AND PLUMBING DRAWINGS. 7. ALL PROPOSED STORM SEWERS, SURFACE OR OTHER DRAINAGE FACILITIES ARE TO BE PRIVATE AND MAINTAINED BY THE OWNER. 8. THE CONTRACTOR IS TO CONSTRUCT CURBS, CATCH BASINS, DOWNSPOUTS, PIPING AND CONNECTION ETC. AS REQUIRED TO CONVEY THE ROOF AND PAVED SURFACE DRAINAGE TO THE DETENTION BASIN. 9. ALL STORM STRUCTURES ARE INDOT TYPES UNLESS OTHERWISE INDICATED. 10. THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE FIELD APPROVAL SUPPLEMENTAL APPROVAL BY THE DESIGN ENGINEER. AN EXPLANATION OF ANY DEVIATION SHALL BE INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES. APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY) SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS AND AS APPROVED BY THE CITY OF CARMEL. 11. STORM SEWER IS TO BE BEDDED WITH CLEAN NO. 8 STONE MEETING THE MATERIAL REQUIREMENTS OF INDOT. THE MATERIAL SHALL BE APPROVED BY THE CITY OF CARMEL DEPARTMENT OF ENGINEERING AT TIME OF INSTALLATION. REFER TO SECTION 501.04 OF THE CITY OF CARMEL STORMWATER TECHNICAL STANDARDS MANUAL. 12. ALL ONSITE STORM SEWERS WILL BE PRIVATE. UTILITY NOTES 1. ALL PROPOSED UTILITY LINES AND EXTENSIONS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH THE CITY OF CARMEL SPECIFICATIONS. CONTRACTOR SHALL COORDINATE UTILITY DISCONNECTIONS WITH THE APPROPRIATE AGENCIES. 2. THE CONTRACTOR IS PARTICULARLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF THE EXISTING UTILITIES SHOWN HEREON IS BASED ON TOPOGRAPHIC SURVEYS AND RECORD DRAWINGS. THE CONTRACTOR SHALL NOT RELY UPON THIS INFORMATION AS BEING EXACT OR COMPLETE. SHOULD UNCHARTED UTILITIES BE ENCOUNTERED DURING EXCAVATION OPERATIONS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER AS SOON AS POSSIBLE FOR INSTRUCTIONS. THE CONTRACTOR SHALL CALL THE APPROPRIATE UTILITY COMPANY AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION AND REQUEST FIELD VERIFICATION OF UTILITY LOCATIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO RELOCATE EXISTING UTILITIES CONFLICTING WITH IMPROVEMENTS SHOWN HEREON IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS GOVERNING SUCH OPERATIONS. 3. THE CONTRACTOR SHALL OBTAIN ALL REQUIRED PERMITS PRIOR TO COMMENCEMENT OF CONSTRUCTION. 4. MAINTAIN MINIMUM 10-FOOT HORIZONTAL AND MINIMUM 18-INCH VERTICAL SEPARATION BETWEEN SANITARY SEWER, STORM SEWER AND WATER SUPPLY LINE, UNLESS OTHERWISE INDICATED. 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE SEQUENCING OF CONSTRUCTION FOR ALL UTILITY LINES SO THAT WATER LINES, GAS LINES, AND UNDERGROUND ELECTRIC DO NOT CONFLICT WITH SANITARY SEWERS OR STORM SEWERS. INSTALL UTILITIES PRIOR TO PAVEMENT CONSTRUCTION. 6. ALL TRENCH SPOILS SHALL BECOME THE PROPERTY OF THE CONTRACTOR UNLESS OTHERWISE DESIGNATED. 7. SANITARY SEWER SHALL BE PVC-SDR 35 PER ASTM D-3034 OR APPROVED EQUAL (CONFORMING TO THE TRICO TYPICAL SANITARY SEWER SPECIFICATIONS) INSTALLED AT A MINIMUM SLOPE OF ONE PERCENT (1.00%) UNLESS OTHERWISE NOTED. SANITARY SERVICE SHALL BE INSTALLED AT A MINIMUM DEPTH OF FOUR FEET (4') UNLESS OTHERWISE NOTED. A MINIMUM OF 18" CLEARANCE SHALL BE MAINTAINED AT ALL WATERLINE & STORM SEWER CROSSINGS. SANITARY SERVICE JOINTS SHALL CONFORM TO ASTM D-3212. 8. SANITARY SEWER IS TO BE BEDDED WITH CLEAN NO. 8 CRUSHED STONE FROM 6" BELOW TO 12" ABOVE THE PIPE. 9. DISTANCES SHOWN FOR BOTH SANITARY AND STORM SEWER PIPES ARE MEASURED FROM CENTER OF STRUCTURE, CONTRACTOR RESPONSIBLE FOR ACTUAL FIELD CUT LENGTH. COORDINATES FOR STORM & SANITARY STRUCTURES ARE SHOWN TO THE CENTER STRUCTURE. UNLESS OTHERWISE NOTED. 10. ROOF DRAINS, FOUNDATION DRAINS AND ALL OTHER CLEAR WATER CONNECTIONS TO THE SANITARY SEWER SYSTEMS ARE PROHIBITED. 11. ADJUST ALL EXISTING UTILITY SURFACE FEATURES INCLUDING BUT NOT LIMITED TO CASTINGS, VALVE BOXES, PEDESTALS, CLEANOUTS, ETC. TO MATCH PROPOSED FINISHED GRADES, UNLESS OTHERWISE INDICATED. 12. THE CONTRACTOR SHALL PROVIDE RECORD DRAWINGS OF ALL IMPROVEMENTS. INCLUDE AT LEAST TWO DIMENSIONS TO EACH VALVE AND MANHOLE FROM KNOWN SITE FEATURES. DRAWINGS SHALL INCLUDE HORIZONTAL AND VERTICAL INFORMATION ON ALL NEW UTILITIES AS WELL AS EXISTING UTILITIES ENCOUNTERED. 13. MECHANICAL/ELECTRICAL CONTRACTORS SHALL BRING ALL UTILITIES 5' OUTSIDE BUILDING WALL. COORDINATE WITH CONSTRUCTION MANAGER/ARCHITECT/ENGINEER/OWNER. 14. ALL WATERLINE CROSSINGS SHALL MAINTAIN A VERTICAL SEPARATION OF 18" MINIMUM. SANITARY SEWER SHALL BE LOCATED A MINIMUM OF 18" BELOW WATERLINE AT ALL CROSSINGS. WATERLINE SHALL BE LOCATED A MINIMUM OF 10' HORIZONTALLY FROM ANY SANITARY SEWER OR STORM SEWER. ALL MEASUREMENTS SHALL BE TAKEN FROM OUTSIDE OF SEWER PIPE TO THE OUTSIDE OF WATERLINE PIPE. ONE FULL LENGTH OF WATERLINE PIPE SHALL BE LOCATED AT ALL CROSSINGS TO ENABLE BOTH JOINTS TO BE LOCATED AS FAR FROM SEWER AS POSSIBLE. 15. WATERLINE IS TO BE BEDDED WITH CLEAN GRANULAR MATERIAL-AGGREGATES HAND TAMPED TO 8 TO 12" ABOVE PIPE. BEDDING MATERIAL SHALL CONFORM TO INDOT 903.02, SIZE NO. 8.CKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805C001 GENERAL NOTES09/14/22 C100 DEMOLITION PLANCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805R Know what'sbelow .Callbefore you dig. R R DEMOLITION NOTES LEGEND 09/14/22 VANVANCOMPACTCOMPACTC200 SITE PLANCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805R Know what'sbelow .Callbefore you dig. R R LEGEND SITE NOTES SITE DATA PARKING DATA UPPER LEVEL ADA PARKING UPPER LEVEL BIKE PARKING 09/14/22 VANVANCOMPACTCOMPACT C201 MAINTENANCE OF TRAFFICCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805R Know what'sbelow .Callbefore you dig. R R LEGEND 09/14/22 VANVANCOMPACTCOMPACTC300 GRADING PLANCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805LEGEND GRADING NOTES LEGEND GRADING NOTES R Know what'sbelow .Callbefore you dig. R R DETAIL SECTION A-A DRAINAGE SUMMARY SECTION B-B 09/14/22 C301 EROSION CONTROL PLAN - PHASE 1CKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805R Know what'sbelow .Callbefore you dig. R R GENERAL NOTES CONSTRUCTION SEQUENCE LEGEND 09/14/22 VANVANCOMPACTCOMPACTC302 EROSION CONTROL PLAN - PHASE 2CKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805R Know what'sbelow .Callbefore you dig. R R GENERAL NOTES CONSTRUCTION SEQUENCE LEGEND SOILS MAP 09/14/22 SEEDING SCHEDULE EROSION CONTROL NOTES · · · SILT FENCE DETAIL CONCRETE WASHOUT DETAIL W = ___ FEET SEDIMENT BARRIER LOG DETAIL . . . .CKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805C303 EROSION CONTROL DETAILS09/14/22 STOCKPILE EROSION CONTROL EROSION CONTROL SCHEDULE SHEET 1 OF 1 DRAWN CHECKED QA MFG APPROVED DWG NO SIZE SCALE REV ALL PRODUCTS MANUFACTURED BY INLET & PIPE PROTECTION, INC DISTRIBUTED BY ADS WWW.INLETFILTERS.COM (866) 287-8655 PH (630) 355-3477 FX INFO@INLETFILTERS.COM INSTALLATION: 1. REMOVE GRATE 2. DROP FLEXSTORM INLET FILTER ONTO LOAD BEARING LIP OF CASTING OR CONCRETE STRUCTURE 3. REPLACE GRATE IPP IPP Flexstorm SpecificationsC · · · · · · TEMPORARY CONSTRUCTION ENTRANCE DETAIL CKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805C304 EROSION CONTROL DETAILS09/14/22 C305 UTILITY PLANCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805LEGENDLEGEND UTILITY NOTES R Know what'sbelow .Callbefore you dig. R R KEY NOTES 09/14/22 C306 STORM NETWORK PROFILECKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805R Know what'sbelow .Callbefore you dig. R R NOTES: STORM SEWER PROFILE STR. NO. 1.6 TO STR. NO. EX 09/14/22 STORM STRUCTURE TABLE C307 STRUCTURE DATA TABLECKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805R Know what'sbelow .Callbefore you dig. R R NOTES: 09/14/22 VANVANCOMPACTCOMPACT(50)CA (1)NS (1)NS (1)NS (1)QR (1)QR (1)QR (1)OV (1)OV (2)PT (2)MS (5)LM (3)BU (5)LM (3)BU (3)PLANTER WITH ANNUALS (5)LM (3)BU (5)LM (3)BU (3)PLANTER WITH ANNUALS (3)CK (30)TH (1)UA (1)UA (1)UA (3)TH (1)OV (2)OV (1)OV (7)AR C400 LANDSCAPE PLANCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.5805R Know what'sbelow .Callbefore you dig. R R * QUANTITIES ARE PROVIDED FOR CONVENIENCE ONLY. CONTRACTOR IS RESPONSIBLE FOR ALL QUANTITIES OF PLANTS ON LANDSCAPE PLAN. LANDSCAPE NOTES TAG QTY SCIENTIFIC NAME COMMON NAME COND. SIZE REMARKS SHADE TREE CK 3 Cladrastis kentuckea American Yellowwood B&B 2" cal. 10'ht. 5'wd Full, well shaped NS 3 Nyssa sylvatica 'Dave Odom'Afterburner Columnar Blackgum B&B 2" cal. 10'ht. 5'wd Full, well shaped QR 3 Quercus robur 'Skyrocket'Skyrocket English Oak B&B 2" cal. 10'ht. 5'wd Full, well shaped UA 3 Ulmus americana 'Princeton'Princeton American Elm B&B 2" cal. 10'ht. 5'wd Full, well shaped ORNAMENTAL TREE OV 6 Quercus robur English Oak B&B 2" cal. 10'ht. 5'wd Full, well shaped, single-stem SHRUB BU 12 Buxus x 'Gelencoe'Chicagoland Green Boxwood #3 cont.18"ht. x 18"wd.Full, vigorous MS 2 Magnolia stellata 'Royal Star'Royal Star Magnolia B&B 36"ht. x 24"wd.Full, vigorous TH 33 Taxus x media 'Hicksii'Hicks Yew #3 cont.18"ht. x 18"wd.Full, vigorous PERENNIAL / ORNAMENTAL GRASS / GROUNDCOVER AR 7 Ajuga reptans 'Bronze Beauty'Bronze Beauty Bugleweed 50/flat 18" on center CA 50 Calamagrostis x acutfifolia 'Karl Foerester'Feather Reed Grass #2 cont.36" on center LM 20 Liriope muscari 'Big Blue'Big Blue Liriope #1 cont. PT 2 Pachysandra terminalis 'Green Carpet'Pachysandra 50/flat 18" on center TREE GRATE PLANTER 09/14/22 EXPANSION JOINT DETAIL EXPANSION JOINT AT BUILDING DETAIL CONTROL JOINT 6" CONCRETE SLAB DETAIL TYPICAL PAVEMENT SECTION TRANSITION FROM SOG TO PRECAST C500 DETAILSCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.580509/14/22 ™ Phone (888) 344-9044 Fax (423) 826-2112 STORMWATER TREATMENT SOLUTIONS www.aquashieldinc.com Aqua-Swirl Concentrator Model AS-4 PCS Standard Detail AS-4 PCS STD 02/05/15 Scale: Drawn By: Document: Date: JCW 1:20 U.S. Patent No. 6524473 and other Patent Pending * Please see accompanied Aqua-Swirl specification notes. * See Site Plan for actual system orientation. ** Orientation may vary from 90°, 180°, or custom angles to meet site conditions. 12" [305 mm] PCS Max A Inlet66" [1676 mm] 12" [305 mm] PCS Max 66" [1676 mm] Outlet A Ø54" [Ø1372 mm] Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Pipe coupling by Contractor. 12" long Stub-out by Manufacturer. Vent Arched Baffle Octagonal Base Plate STORMWATER TREATMENT SOLUTIONS Phone (888) 344-9044 www.aquashieldinc.com ™ Vent Arched Baffle Slide riser over top ring and bolt in 4 placesRiser 68" [1727 mm] 104" [2642 mm] Swirl Inlet Swirl Outlet Bedding Undisturbed Soil Backfill 6" [152 mm] 18" [457 mm] Section A-A Plan View Grade (Rim) 30" [762 mm] Rim elevations to match finished grade. Manhole Frame and Cover by Manufacturer. (See Details)5" [127 mm] MH Frame Varies 90°** Varies Backfill shall extend at least 18 inch [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below) 4 1/2" [114 mm] 1/2" [13 mm] 1" [25 mm] Manhole Frame & Cover Detail NTS For Non-Traffic Areas Only Soil 1" [25 mm] Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles. Soil Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame. DO NOT allow manhole frame to rest upon riser. Riser Frame Cover 48" [1219 mm] Min. 12" [305 mm] Wrap Compressible Expansion Joint Material to a minimum 1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab. Backfill (90% Proctor Density) Concrete Concrete8" [203 mm] Gravel Backfill Gravel Backfill 4 1/2"Cover Frame 1" [25 mm] ThickExpansion JointMaterial30" [762 mm] Riser #4 [13 mm] Rebar @ 6" [152 mm] Each Way 14"1/2" 3,000 psi [20 MPa] (min) Concrete Manhole Frame & Cover Detail For Traffic Loading Areas NTS If traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1-inch [25 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade. Backfill (90% Proctor Density) 48" Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System 2733 Kanasita Drive, Suite 111, Chattanooga, TN 37343 Note: AS an alternative, 42-inch OD, HS-25 rated precast concrete rings may be substituted. 14-inch thickness must be maintained. PRECAST CONCRETE WHEEL STOP PIPE CROSSING ENCASEMENT DETAIL ADA PAVEMENT SYMBOL ADA PARKING SIGN CONCRETE STOOP DETAIL (ADJACENT TO SIDEWALK) CONCRETE STOOP DETAIL FIRE HYDRANT ASSEMBLY DIVERSION STRUCTURE DETAIL C501 DETAILSCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.580509/14/22 TYPICAL CONSTRUCTION FOR LATERAL CONNECTIONS TYPE 1, 2 & 3 STR. NO. 1.6 OUTLET CONTROL STRUCTURE PIPE CONNECTION TO EXISTING MANHOLE INLET TYPE "A" (TYPICAL) INLET TYPE "E" MANHOLE TYPE "B" CATCH BASIN TYPE "A" C502 DETAILSCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.580509/14/22 C503 DETAILSCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.580509/14/22 1/4"x2"x16" BENT PLATE ANCHOR WELDED TO TUBE SECTION 8" THICK POURED CONCRETE SLAB TS 8 X 6 COLUMN - ONE EACH SIDE OF GATE (B-1) BRICK VENEER TO MATCH BUIILDING, COLLAR JOINT ON BLOCK WALL 6" DIA STEEL BOLLARD FILLED WITH CONCRETE 10" POURED CONC. FTG. @ MIN. 42" BELOW GRADE W/ (2)- #4 BARS & TOP & BOTT. (2)6"Ø CONCRETE FILLED STEEL BOLLARD #4 BARS @ 16" O.C. x 48" LONG 12" POURED CONC. FTG. @ 42" BELOW GRADE W/ (2)-#4 BARS @ TOP & BOT. SLOPED STONE CAP COLOR TO MATCH MAIN BUILDING BRICK VENEER TO MATCH BUILDING 8" THICK CONC. SLAB ON 4" GRANULAR FILL (2)- #4 BARS GATE HARDWARE 1x6 WP-6 CEDAR VERTICAL SIDING ON 1/2" CDX PLYWOOD ON EACH SIDE OF 2x6 WELDED TUBE FRAME 1x6 WP-6 CEDAR VERTICAL SIDING ON 1/2" CDX PLYWOOD ON EACH SIDE OF 2x6 WELDED TUBE FRAME 1/4"x2"x16" BENT PLATE ANCHOR WELDED TO TUBE SECTION TS8x6 ANCHORED TO SCREEN WALL CAP W/ 1/4" STEEL PLATE- WELD & GRIND BRICK VENEER TO MATCH STYLE & COLOR OF BUILDING FOUNDATION SLOPED STONE CAP TO MATCH BUILDING HEAVY DUTY OFFSET GATE HINGE- (4) PER LEAF TS8"x6" ANCHORED TO SCREEN WALL 1x6 WP-6 CEDAR VERTICAL SIDING ON 1/2" CDX PLYWOOD ON EACH SIDE OF 2x6 WELDED TUBE FRAME 2"x6"x3/8" WELDED TUBE FRAME 1x6 WOOD TRIM BRICK VENEER TO MATCH STYLE & COLOR OF BUILDING 6' HIGH DUMPSTER BEYOND 6' HIGH DUMPSTER BEYOND 6' HIGH DUMPSTER BEYOND 6' HIGH DUMPSTER DUMPSTER HGTENCLOSURE HGT.DUMPSTER ENCLOSURE EXTERIOR BUILDING WALL TO PROVIDE 3RD SIDE OF DUMPSTER ENCLOSURE EXTERIOR BUILDING WALL TO PROVIDE 3RD SIDE OF DUMPSTER ENCLOSURE C504 DETAILSCKD.DR.DES.DATEPROJECT No:REVISIONDATENo.PROSCENIUM PHASE II (1215)1215 SOUTH RANGELINE ROADCARMEL, INDIANA333 North Alabama StreetSuite 200Indianapolis, IN 46204317.299.7500FAX: 317.291.580509/14/22