HomeMy WebLinkAboutTW Audi Service C802C802CONSTRUCTION DETAILSMANHOLE & INLETSSTORM SEWER4610-B EAST 96TH STREET
TOM WOOD AUDI
CARMEL, INDIANA
SERVICE ADDITIONJOB#: TWI.013DRAWN BY: RCW
(317) 251-1738 (FAX) 251-1923
INDIANAPOLIS, INDIANA 46220
6555 CARROLLTON AVENUE
www.rw-engineering.com
CIVIL ENGINEERS - LAND SURVEYORS - DEVELOPMENT CONSULTANTS
DATE: 03/21/232733 Kanasita Drive, Suite 111, Chattanooga, TN 37343Phone (888) 344-9044 Fax (423) 826-2112www.aquashieldinc.comStructure #:Drawn By:Scale:Date:6/26/2019RvwedRvw. DateU.S. Patent No. 6524473 and other Patent PendingAqua-Swirl XCeleratorAs ShownOFloresAqua-Swirl Stormwater Treatment SystemStandard DetailXC-7 CCW STDXC-7 STDAqua-Swirl Polymer Coated Steel (PCS)Stormwater Treatment System12 in[305 mm]Manhole Frame & Cover DetailFor Non-Traffic Areas OnlyNTS4 in[1219 mm] Min.Gravel BackfillConcreteWrap Compressible ExpansionJoint Material to a minimum1/2-inch [13 mm] thickness aroundtop of riser to allow transfer ofinadvertent loading frommanhole cover to concrete slab.RiserSoilCoverFrame1/2 in[13 mm]1/2 in[13 mm]Place small amount ofconcrete [3,000 psi [20MPa] (min)] to supportand level manhole frame.DO NOT allow manholeframe to rest upon riser.Backfill (90%Proctor Density)8 in[203 mm]4 1/2 in[114 mm]Unless other traffic barriers are present,bollards shall be placed around access riser(s)in non-traffic areas to prevent inadvertentloading by maintenance vehicles.Manhole Frame & Cover DetailFor Traffic Loading AreasNTSCoverFrame48 in[1219 mm] Min.Backfill (90%Proctor Density)3,000 psi [20 MPa](min) Concrete#4 [13 mm] Rebar@ 6 in [152 mm]Each Way30 in [762 mm]Riser1/2 in[13 mm]4 1/2 in[114 mm]14 in[356 mm]1/2 in [13 mm] ThickExpansion JointMaterialIf traffic loading (HS-25) is required or anticipated, a 4-foot [1.22 m]diameter, 14-inch [356 mm] thick reinforced concrete pad must beplaced over the Stormwater Treatment System Riser to support andlevel the manhole frame, as shown. The top of riser pipe must bewrapped with compressible expansion joint material to a minimum1/2-inch [13 mm] thickness to allow transfer of wheel loads frommanhole cover to concrete slab. Manhole cover shall bear on concreteslab and not on riser pipe. The concrete slab shall have a minimumstrength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm]reinforcing steel as shown. Minimum cover over reinforcing steel shallbe 1-inch [25 mm]. Top of manhole cover and concrete slab shall belevel with finish grade.Please see accompanied Aqua-Swirl specification notes. See SitePlan for actual System orientation. Approximate dry (pick) weight:3800 lbs [1700 kg].Backfill shall extend at least 18inches [457 mm] outward fromSwirl Concentrator and for thefull height of the SwirlConcentrator (including riser)extending laterally toundisturbed soils. (See MHDetail Below)BackfillBeddingUndisturbed soil18 in[457 mm]6 in[152 mm]11As an alternative, 42 in [1067 mm] diameter, HS-20/25rated precast concrete rings may be substituted. 14 in[356 mm] thickness must be maintained.XC-7 inlet/outlet pipe size ranges up to 42 in [1067 mm].XC-7 chamber height may vary up to 151 in [3835 mm],depending on inlet/outlet pipe size.Orientation may vary from a minimum of 90° to amaximum of 180°. Clockwise or counterclockwiseorientation as needed.2332Plan ViewSCALE 1:40 96 in[2438 mm] 96 in[2438 mm] n42 in[1067 mm] n42 in[1067 mm]2Octagonal Base Plate Ø84 in[Ø2137 mm]Elevation ViewSCALE 1:40 85 in[2159 mm] 151 in[3835 mm][1067 mm][940 mm] 5 MH Frame[127 mm] n30 in[762 mm]Band Couplerby Manufacturer.(as needed)RiserManhole Frame andCover by Manufacturer.(See Details)Rim elevations tomatch finish grade.Pipe couplingby Contractor.12 in [305 mm]long Stub-outby Manufacturer.44el. VariesInlet/Outlet Invertel. Variesel. VariesGrade (Rim) el. VariesPipe couplingby Contractor.12 in [305 mm]long Stub-outby Manufacturer.180° n84 in[2134 mm]Projected ViewSCALE 1:70Optional inletorientations available(See note 4)10/16/2023