HomeMy WebLinkAbout2018-0524 West Park - The Groves Final Drawings3030 W. 116th StreetCarmel, IN 46032Stormwater Management Permit Drawing ResubmitOriginal = December 12, 2017Revised = May 4, 2018WEST PARK:THE GROVESSGJJR PROJECT # 22109.000Site DrawingsSheet Number Sheet TitleG000Cover SheetG002 Key Plan & General NotesV001Existing Conditions PlanV002Existing Conditions PlanV003Existing Conditions PlanV004Existing Conditions PlanC101SWPP PlanC102SWPP PlanC103SWPP PlanC104SWPP PlanC105 Site Preparation PlanC106 Site Preparation PlanC107 Site Preparation PlanC108 Site Preparation PlanC109Layout and Materials PlanC110Layout and Materials PlanC111RESERVEDC112RESERVEDC113Grading PlanC114Grading PlanC115Grading PlanC116RESERVEDC117Utilities PlanC118Utilities PlanC119RESERVEDC120RESERVEDC121Detention PlanC122Fire Truck Access Plan - ArrivalC123Fire Truck Access Plan -DepartureC401Layout and Materials EnlargementC402Layout and Materials EnlargementC403Layout and Materials EnlargementC404Layout and Materials EnlargementC405 Grading EnlargementsC406 Grading EnlargementsC407 Grading EnlargementsC408 Grading EnlargementsC500 Stormwater Pollution PreventionNotesC501 Stormwater Pollution PreventionDetailsC502Site DetailsC503Site DetailsC504Site DetailsC505RESERVEDC505.1RESERVEDC506Site DetailsC507Site DetailsC507.1Site DetailsC508Site DetailsC509Site DetailsC510Utility DetailsC511Utility DetailsC512Utility DetailsC125Landscape PlanC126Landscape PlanC127Landscape PlanC409Landscape Enlargement PlanC410Landscape Enlargement PlanC411Landscape Enlargement PlanC513 Landscape Planting ScheduleC514Landscape DetailsPROJECT VICINITY MAPPrepared for:Prepared by:Project AreaNorthNOT TO SCALEWEST PARK:THE GROVES500 PARK BOULEVARDSUITE 800ITASCA, IL 60143630.221.1212www.williams-architects.com44 EAST MIFFLIN STREETSUITE 500MADISON, WI 53703608.251.1177www.smithgroupjjr.com1-800-382-5544811CALL TOLL FREEFOR CALLS INSIDE OF INDIANA"DON'T DIG BLIND"HOLEY MOLEY SAYSIT IS AGAINST THE LAW TO EXCAVATEWITHOUT NOTIFYING THE UNDERGROUNDLOCATION SERVICE TWO (2) WORKINGDAYS BEFORE COMMENCING WORK.PER INDIANA STATE LAW IC 8 1 26.LANDSCAPE ARCHITECT, CIVIL &SITE ELECTRICAL ENGINEERARCHITECT1427 EAST 116TH STREETCARMEL, IN 46032317.848.7275carmelclayparks.cominfo@carmelclayparks.comProfessional Seals:Civil Engineer's Stampdave.wolmutt@smithgroupjjr.comPROJECT INFOLOT AREA40.15 acresTOTAL SITE DISTURBANCE8.5 acresZONING DISTRICTP-1: Parks and RecreationSETBACK DISTANCESFRONT YARD (min.)40 feetSIDE YARD (min.)20 feetREAR YARD (min.)15 feetLOT COVERAGE RATIOMAXIMUM35%DESIGN0.5%LEGAL DESCRIPTION35.14 Acre ParcelA part of the Southwest Quarter of Section 32, Township 18North, Range 3 East of the Second Principal Meridian in ClayTownship, Hamilton County, Indiana being more particularlydescribed as follows:Commencing at the southwest comer of the Southwest Quarterof Section 32, Township 18 North, Range 3 East of the SecondPrincipal Meridian in Clay Township, Hamilton County, Indiana;thence North 89 degrees 34 minutes 15 seconds East (basis ofbearing Instrument #94-13908) 1,325.46 feet to the southwestcomer of the Southeast Quarter of the Southwest Quarter of saidSection 32, said comer is the POINT OF BEGINNING of theherein described tract; thence North 00 degrees01 minute 33seconds West 1,317.74 feet to the northwest comer of saidquarter-quarter section; thence North 89 degrees 28 minutes 41seconds East 1,326.32 feet to the northeast corner of saidquarter-quarter section; thence South 00 degrees 00 minutes 39seconds West 31.86 feet on the east line of the SouthwestQuarter of said Section 32 to the northeast comer of that landdescribed as Parcel 3B in Instrument #94-13908 and recorded inthe Office of the Hamilton County Recorder; thence South 89degrees 34 minutes 15 seconds West 169.00 feet on the northline of said parcel; thence South 00 degrees 00 minutes 39seconds West 1,288.04 feet, parallel with the east line of theSouthwest Quarter of said Section 32, to a point on the southline of said quarter section; thence South 89 degrees 34 minutes15 second West 1,156.46 feet on the south line of said quartersection to the POINT OF BEGINNING, said tract contains 35.14acres more or less.LEGAL DESCRIPTION5.00 Acre ParcelA part of the Southwest Quarter of Section 32,Township 18 North, Range 3 East of theSecond Principal Meridian in Clay Township,Hamilton County, Indiana being moreparticularly described as follows:BEGINNING at the southeast comer of theSouthwest Quarter of Section 32, Township 18North, Range 3 East of the Second PrincipalMeridian in Clay Township, Hamilton County,Indiana; thence South 89 degrees 34 minutes15 seconds West (basis of bearing Instrument#94-13908) 169.00 feet on the south line of saidquarter section; thence North 00 degrees 00minutes 39 seconds East 1,288.04 feet to apoint on the north line of that8.00 acre tract (Parcel #38) described in recordInstrument #94-13908 and recorded in theOffice of the Hamilton County Recorder; thenceNorth 89 degrees 34 minutes 15 seconds East169.00 feet on the north line of said 8.00 acretract to a point on the east line of the SouthwestQuarter of said Section 32; thence South 00degrees 00 minutes 39 seconds West 1,288.04feet on the east line of said quarter section tothe POINT OF BEGINNING, said tract contains5.00 acres more or less.OWNER:OPERATING AUTHORITY: CITY OF CARMEL, INDIANAC124RESERVEDC128RESERVED
LIMITS OF WORK
FUTURE MULTI-USE PATH
10' WIDE, MINIMUM 8' SEPARATION FROM 116TH STREET
(NOT IN CONTRACT, TO BE INSTALLED IN PHASE 2 OF PROPOSED
DEVELOPMENT, TO BE PERMITTED AS PART OF SEPARATE
PROJECT.)
GENERAL NOTESN
Key Plan & General Notes
0'160'80'40'
SCALE: 1" = 80'
G002
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
1.NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN
APPROVED STORM WATER MANAGEMENT PERMIT.
2.PRIOR TO START OF PROJECT WORK, VERIFY ALL SITE
CONDITIONS AND SUBMIT A PROJECT WORK PLAN TO THE
ARCHITECT/ENGINEER FOR REVIEW AND COMMENT. PRESENT
THE WORK PLAN AT THE OWNER'S PRE-CONSTRUCTION
MEETING. DO NOT BEGIN PRIOR TO THE 'PRE-CONSTRUCTION
MEETING' AND WRITTEN AUTHORIZATION TO PROCEED IS
ISSUED BY THE OWNER.
3.NOTIFY THE ARCHITECT/ENGINEER IN WRITING OF ANY
IDENTIFIED DISCREPANCIES WITHIN THE CONSTRUCTION
DOCUMENTS PRIOR TO THE START OF WORK. DURING
PERFORMANCE OF THE WORK, VERIFY ALL DIMENSIONS AND
CONDITIONS AT THE JOB SITE AND CROSS-CHECK DETAILS AND
DIMENSION SHOWN ON THE DRAWINGS WITH RELATED
REQUIREMENTS ON THE ARCHITECTURAL, MECHANICAL,
ELECTRICAL AND PLUMBING DRAWINGS. CONTRACTOR SHALL
VERIFY ALL SITE CONDITIONS PRIOR TO STARTING WORK. IN
ALL CASES WHERE A CONFLICT MAY OCCUR, THE
ARCHITECT/ENGINEER SHALL BE NOTIFIED AND WILL
INTERPRET THE INTENT OF THE CONTRACT DOCUMENTS.
4.PRIOR TO THE COMMENCEMENT OF WORK, VERIFY LOCATIONS
AND DEPTHS OF ALL UNDERGROUND UTILITIES THAT MAY BE
AFFECTED BY CONSTRUCTION AND TAKE RESPONSIBILITY FOR
DAMAGES TO SUCH UTILITIES CAUSED AS A RESULT OF
CONSTRUCTION.
5.TAKE ALL NECESSARY PRECAUTIONARY MEASURES TO
PROTECT THE PUBLIC AND ADJACENT PROPERTIES FROM
DAMAGE THROUGHOUT CONSTRUCTION, INCLUDING DAMAGES
TO UTILITIES, WALKS, WALLS, DRIVES, CURBS, ETC.
6.SECURE ALL NECESSARY PERMITS AND NOTIFY ALL UTILITY
COMPANIES WITH UTILITIES ON THE SITE PRIOR TO THE
CONSTRUCTION OF THE PROJECT. ADHERE TO ALL
APPLICABLE LOCAL, STATE AND FEDERAL LAWS OR
REGULATIONS PERTAINING TO THE PROJECT.
7.ESTABLISH AND MAINTAIN SITE SECURITY UNTIL PROJECT
ACCEPTANCE.
8.USE DIMENSIONS SHOWN ON DRAWINGS FOR LAYOUT OF THE
WORK. DO NOT USE SCALE DIMENSIONS FROM PLANS,
SECTIONS OR DETAILS ON THE DRAWINGS.
9.REFER TO THE SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS NOT SHOWN ON DRAWINGS.
10.DETAILS NOTED AS TYPICAL SHALL APPLY IN ALL CASES
UNLESS SPECIFICALLY SHOWN OR NOTED OTHERWISE.
WHERE NO SPECIFIC DETAIL IS SHOWN, THE CONSTRUCTION
SHALL BE IDENTICAL OR SIMILAR TO THAT INDICATED FOR LIKE
CASES OF CONSTRUCTION ON THIS PROJECT.
11.TAKE NOTE OF ALL GRADING AND DRAINAGE WAYS AND
MAINTAIN THESE DRAIN WAYS FLOWS FREE OF
OBSTRUCTIONS.
12.COORDINATE CONSTRUCTION OF PENETRATIONS, SLEEVES,
VARIATIONS IN THE SLAB ELEVATIONS, DEPRESSED AREAS AND
ALL OTHER ARCHITECTURAL, MECHANICAL, ELECTRICAL AND
PLUMBING REQUIREMENTS.
13.DISPOSE ALL ELEMENTS DESIGNATED FOR REMOVAL IN A
LEGAL MANNER. PROVIDE RECEIPTS AND LETTERS FROM
DISPOSAL SITES TO OWNER AS REQUIRED BY THE OWNER.
14.PREPARE ALL SUBGRADES IN ACCORDANCE WITH
RECOMMENDATIONS OF GEOTECHNICAL ENGINEER. PROVIDE
PROOF OF ALL REQUIRED SOIL COMPACTION TO THE OWNER.
15.ALL CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE
CODES, REGULATIONS, AND ORDINANCES.
16.COORDINATE WORK OF SUBCONTRACTORS AND ALL OTHER
CONTRACTORS TO ENSURE ORDERLY AND EFFICIENT
COMPLETIONS OF ALL WORK.
17.ALL EXISTING PERIMETER ROAD DRAINAGE STRUCTURES AND
BRIDGES ACROSS THE FRONTAGE OF THIS DEVELOPMENT ARE
INDICATED ON THE PLANS. PROVISIONS HAVE BEEN MADE TO
IMPROVE OR REPLACE ANY DRAINAGE STRUCTURES AND
BRIDGES AS NECESSARY OR AS REQUEST BY THE CITY TO
ACCOMMODATE THE PAVEMENT WIDENING, AUXILIARY LANES,
MULTI-USE PATH, AND ANY OTHER REQUIRED IMPROVEMENTS
TO THE PROPERTY OR THE ROADWAY. THE COST TO IMPROVE
OR REPLACE ANY DRAINAGE STRUCTURES AND BRIDGES WILL
BE BORNE BY THE OWNER.
18.UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE
THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE
RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT
IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE
DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE
LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF
PROPOSED RIGHT-OF-WAY LINE.
SOUTHWEST QUADRANT SHEETS
V-003: EXISTING CONDITIONS PLAN
C-103: SWPP PLAN
C-107: SITE PREPARATION PLAN
C-111: RESERVED (EXCLUDED THIS SET)
C-115: GRADING PLAN
C-119: RESERVED (EXCLUDED THIS SET)
L-103:LANDSCAPE PLAN
NORTHWEST QUADRANT SHEETS
V-004: EXISTING CONDITIONS PLAN
C-104: SWPP PLAN
C-108: SITE PREPARATION PLAN
C-112: RESERVED (EXCLUDED THIS SET)
C-116: RESERVED (EXCLUDED THIS SET)
C-120: RESERVED (EXCLUDED THIS SET)
L-104:RESERVED (EXCLUDED THIS SET)
NORTHEAST QUADRANT SHEETS
V-002: EXISTING CONDITIONS PLAN
C-102: SWPP PLAN
C-106: SITE PREPARATION PLAN
C-110: LAYOUT & MATERIALS PLAN
C-114: GRADING PLAN
C-118: UTILITY PLAN
L-102:LANDSCAPE PLAN
SOUTHEAST QUADRANT SHEETS
V-001: EXISTING CONDITIONS PLAN
C-101: SWPP PLAN
C-105: SITE PREPARATION PLAN
C-109: LAYOUT & MATERIALS PLAN
C-113: GRADING PLAN
C-117: UTILITY PLAN
L-101:LANDSCAPE PLAN
MATCHLINE
MATCHLINEMATCHLINEMATCHLINE
1
STORMWATER PERMIT RESUBMIT 05/04/181
MATCHLINE: SEE SHEET V002
MATCHLINE: SEE SHEET V003N
Existing Conditions Plan
0'80'40'20'
SCALE: 1" = 40'
V001
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
LEGEND
GENERAL NOTES
1. PERIMETER LINES OF THE SUBJECT TRACT ARE SHOWN ON THIS SURVEY FOR
REFERENCE PURPOSES. THESE LINES HAVE BEEN ESTABLISHED BASED UPON
RECOVERED MONUMENTATION AND RECORD DEED OR PLAT GEOMETRY, AND
REPRESENT AN APPROXIMATE LOCATION OF THESE LINES. THIS INFORMATION
HAS BEEN DEPICTED TO ALLOW FOR DISPLAY OF EASEMENT AND RIGHT-OF-WAY
LINES PER THE CLIENT'S REQUEST. NOTE THAT THIS SURVEY IS NOT A
BOUNDARY SURVEY, AND NOT ALL ASPECTS OR EVIDENCE OF BOUNDARY HAVE
BEEN ANALYZED AND ADDRESSED.
2. THE RIGHT-OF-WAY OF WEST 116TH STREET HAS BEEN DEPICTED HEREON BASED
UPON ROADWAY CLASSIFICATION SHOWN IN THE CARMEL CLAY COMPREHENSIVE
PLAN, LAST REVISED ON MARCH 10, 2016. WEST 116TH STREET IS CLASSIFIED AS
A PARKWAY ARTERIAL STREET WITH A 120-FOOT RIGHT-OF-WAY IN THIS PLAN, SO
A 60-FOOT HALF RIGHT-OF-WAY HAS BEEN DEPICTED HEREON. THE SURVEYOR
DID NOT FIND RECORDED DEEDS OR EASEMENTS FOR RIGHT-OF-WAY PURPOSES
ALONG THIS ROADWAY OVER MUCH OF THE SUBJECT TRACT. A 40-FOOT WIDE
DEDICATION OF PUBLIC RIGHT-OF-WAY TO THE HAMILTON COUNTY BOARD OF
COMMISSIONERS WAS FOUND OVER THE EASTERLY PART OF THE SUBJECT
TRACT, AS SHOWN HEREON.
3. THE OVERHEAD ELECTRIC LINE RUNNING IN A NORTH-SOUTH DIRECTION LYING
WEST OF THE DRIVEWAY AND HOUSE APPEARS TO FALL EAST OF THE 10-FOOT
ELECTRIC LINE EASEMENT. THE EASEMENT IS SHOWN BASED UPON THE
EASEMENT DESCRIPTION RELATED TO THE APPROXIMATE BOUNDARY
RESOLUTION, AND MAY BE SUBJECT TO UNCERTAINTY PENDING A FULL
BOUNDARY RETRACEMENT SURVEY.
4. WETLAND DELINEATION MARKERS WERE OBSERVED IN SEVERAL LOCATIONS OF
THE SUBJECT TRACT, AS SHOWN HEREON. IN ADDITION, WETLANDS DELINEATION
GIS SHAPEFILES RECEIVED FROM THE CLIENT HAVE BEEN DEPICTED HEREON. IN
MOST AREAS, THE GIS SHAPEFILES MOSTLY CORRESPOND WITH THE OBSERVED
MARKERS, BUT IN SOME AREAS MARKER FLAGS WERE LOCATED BUT NO GIS
SHAPEFILE LINE WAS SHOWN IN THE AREA.
5. ACCESS TO THE NORTH ADJOINING TRACT WAS NOT PERMITTED AT REQUEST OF
THE ADJOINING LANDOWNERS. TOPOGRAPHIC SURVEY INFORMATION WAS NOT
OBTAINABLE IN THIS AREA.
6. A 30-FOOT WIDE GAS LINE EASEMENT RUNS ALONG THE SOUTHERLY PART OF THE
SUBJECT TRACT, AS SHOWN HEREON. THE GAS LINE WAS NOT MARKED IN THIS
AREA. UTILITY MARKINGS ONLY SHOWED THE GAS LINE IN THE EAST ADJOINING
TRACT. A SECOND REQUEST FOR UTILITY LOCATION DID NOT RESULT IN ANY
ADDITIONAL GAS LINE BEING MARKED. MAPPING RECORDS FROM VECTREN
SHOW A 6" PLASTIC GAS LINE RUNNING THROUGH THE SUBJECT TRACT.
7. TREES 6-INCHES OR GREATER IN DIAMETER HAVE BEEN LOCATED AND SHOWN
HEREON AT CLIENT'S REQUEST. DUE TO THE EXISTING SITE CONDITIONS, IT IS
POSSIBLE THAT SOME TREES MAY HAVE BEEN ACCIDENTALLY OVERLOOKED. IN
ADDITION, TREES LESS THAN 6 INCHES IN DIAMETER HAVE NOT BEEN SHOWN
HEREON. THE CLIENT IS ADVISED THAT THE TREES SHOWN HEREON DO NOT
REPRESENT THE FULL EXTENT OF TREES LOCATED ON THE SUBJECT TRACT.
8. THE OWNER WILL REMOVE ALL TREES INDICATED AS ASH TREES ON THIS SURVEY
PRIOR TO CONSTRUCTION. AS-BUILT DRAWINGS OF REMOVALS TO BE PROVIDED
TO CONTRACTOR. REMOVALS TO BEGIN JANUARY 2018 AND ANTICIPATED TO BE
COMPLETE IN MARCH 2018.
9. NO EXISTING 100 YEAR FLOODPLAINS, FLOODWAY FRINGES, OR FLOODWAYS
EXIST WITHIN EXISTING SITE OR EXISTING SURVEY LIMITS, PER FEMA FIRM PANEL
18057C0205G, DATED 11/19/2014.
10. SEE SHEET V002 FOR BENCHMARK INFORMATION.
POND NORMAL WATER ELEVATION: 895.5±
MATCHLINE: SEE SHEET V001MATCHLINE: SEE SHEET V004N
Existing Conditions Plan
0'80'40'20'
V002
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SCALE: 1" = 40'
LEGEND
GENERAL NOTES
1. SEE SHEET V001 FOR EXISTING CONDITION PLAN NOTES.
MATCHLINE: SEE SHEET V004
MATCHLINE: SEE SHEET V001N
Existing Conditions Plan
0'80'40'20'
V003
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SCALE: 1" = 40'
LEGEND
GENERAL NOTES
1. SEE SHEET V001 FOR EXISTING CONDITION PLAN NOTES.
2. SEE SHEET V002 FOR BENCHMARK INFORMATION.
MATCHLINE: SEE SHEET V003 MATCHLINE: SEE SHEET V002N
Existing Conditions Plan
0'80'40'20'
V004
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SCALE: 1" = 40'
LEGEND
GENERAL NOTES
1. SEE SHEET V001 FOR EXISTING CONDITION PLAN NOTES.
2. SEE SHEET V002 FOR BENCHMARK INFORMATION.
MATCHLINE: SEE SHEET C102
MATCHLINE: SEE SHEET C103LIMITS OF WORK
SILT FENCE
CULVERT PROTECTION
STABILIZED CONSTRUCTION ENTRANCE
CONCRETE WASHOUT
TREE PROTECTION FENCE
TEMPORARY CONSTRUCTION FENCE
N
SWPP Plan
0'80'40'20'
C101
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
1
SWPPP NOTES
SWPPP LEGEND
1. CONTRACTOR SHALL PROVIDE TEMPORARY SEDIMENTATION BASINS
AT LOCATION OF PROPOSED WET PONDS, SEE GRADING PLANS.
2. EARTHMOVING MAY NOT COMMENCE UNTIL ITEMS #2-#4 OF
"PRECONSTRUCTION ACTIVITIES" ON THIS SHEET HAVE BEEN
COMPLETED, IN ADDITION TO ITEMS DEPICTED ON PLAN.
3. IDEM RULE 5 REQUIRES ALL DISTURBED AREAS THAT WILL
POTENTIALLY BE IDLE FOR 15 DAYS OR MORE TO BE STABILIZED
(SEEDED, MULCHED, ETC.) IMMEDIATELY.
4. ADDITIONAL STORMWATER POLLUTION PREVENTION MAY BE
REQUIRED IN THE FIELD BY CITY OF CARMEL.
5. THERE SHALL BE NO DIRT, DEBRIS OR STORAGE OF MATERIALS IN
THE STREETS.
6. APPROXIMATE CONSTRUCTION SCHEDULE
6.1. START DATE = MARCH 1, 2018
6.2. COMPLETION DATE = MAY 1, 2019
7. RECEIVING WATER = WILLIAMS CREEK
8. PROJECT LOCATION
8.1.LATITUDE = 39°57'27.63"N
8.2.LONGITUDE = 86°12'48.49"W
9. CONTACT PERSON:
CARMEL/CLAY PARKS AND RECREATION
MICHAEL KLITZING, CHIEF OPERATING OFFICER
1411 EAST 116TH STREET
CARMEL, IN 46032
PH: 317-573-4018
10. SEE SHEET C500 & C501 FOR STORMWATER POLLUTION
PREVENTION NOTES AND DETAILS.
SCALE: 1" = 40'2
3
4
5
24.00'150.00'4
1
2
3
MINIMIZE IMPACTS
WITH FENCE REMOVAL
PRECONSTRUCTION ACTIVITIES
1. EARTHMOVING MAY NOT COMMENCE UNTIL ITEMS #2-#4 OF
"PRECONSTRUCTION ACTIVITIES" ON THIS SHEET HAVE BEEN
COMPLETED, IN ADDITION TO ITEMS DEPICTED ON PLAN.
2. INSTALL STONE ACCESS DRIVE OFF 116TH STREET.
3. CONSTRUCT STAGING AREA NEAR CONSTRUCTION ENTRANCE.
ALSO CONSTRUCTION RULE 5 INFORMATION POSTING BOX, INSTALL
TRASH DUMPSTER, AND PLACE PORT-O-LET, AS SHOWN ON SHEET
C501.
4. INSTALL SILT FENCE AS SHOWN ON SHEET C101 - C104.
5. STRIP TOPSOIL AND ORGANIC MATERIAL FROM CONSTRUCTION
AREA FOR REUSE.
6. IF WORK ON SITE WILL STOP FOR TWO WEEKS OR MORE AFTER
COMPLETION OF MASS GRADING, INSTALL TEMPORARY SEED AS
INDICATED ON CHARTS LOCATED ON SHEET C500.
7. MAINTAIN ALL INLET PROTECTION AND SILT FENCING IN THIS
PROJECT BY CLEANING OUT EVERY WEEK AND AFTER EVERY
STORM EVENT.
SITE SPECIFIC CONSTRUCTION SEQUENCE
1. REPAIR OR REPLACE SILT FENCE INSTALLED DURING MASS
EARTHWORK PHASE.
2. REPAIR CONSTRUCTION ENTRANCE INSTALLED IN MASS GRADING
PHASE.
3. INSTALL OR REPAIR CONCRETE WASHOUT BASIN, AS INDICATED ON
PLANS.
4. REPAIR CONSTRUCTION STAGING AREA ORIGINALLY SET UP DURING
MASS GRADING.
5. COMPLETE AND/OR REPAIR EARTHWORK AND COMPACTION FOR
PAVEMENT SUBGRADES AND INSTALL PERMANENT SUBBASE
MATERIAL.
6. COMPLETE EARTHWORK AND FINISH GRADING FOR SEEDED AREAS.
APPLY SEED AND MULCH WITHIN 30 HOURS OF SEEDBED
PREPARATION.
7. PERMANENTLY SEED AND MULCH WHERE INDICATED ON PLANS.
8. STABILIZATION OF A PROJECT SITE IS CONSIDERED ACHIEVED WHEN
ALL LAND DISTURBING ACTIVITIES HAVE BEEN COMPLETED AND A
UNIFORM PERENNIAL VEGETATIVE COVER WITH A DENSITY OF 70%
HAS BEEN ESTABLISHED ON ALL UNPAVED AREAS AND AREAS NOT
COVERED BY PERMANENT STRUCTURES, OR EQUIVALENT
PERMANENT STABILIZATION MEASURES HAVE BEEN EMPLOYED.
9. THE CONTRACTOR SHALL MAINTAIN EROSION CONTROL MEASURES
AND DEVICES DURING CONSTRUCTION AND UNTIL SILTATION WILL
NO LONGER OCCUR.
10. AFTER THE CONTRACTOR HAS REMOVED TEMPORARY EROSION
CONTROL MEASURES ANY DISTURBED AREAS SHALL BE RE-SEEDED
AS REQUIRED.
NPDES POSTING BOX
5
6
7
7
6
7
7
2
2
MATCHLINE: SEE SHEET C102MATCHLINE: SEE SHEET C101MATCHLINE: SEE SHEET C102MATCHLINE: SEE SHEET C104LIMITS OF WORK
SILT FENCE
CULVERT PROTECTION
STABILIZED CONSTRUCTION ENTRANCE
CONCRETE WASHOUT
TREE PROTECTION FENCE
TEMPORARY CONSTRUCTION FENCE
N
SWPP Plan
0'80'40'20'
C102
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SWPPP NOTES
SWPPP LEGEND
1. SEE SHEET C101 FOR SWPP NOTES, PRECONSTRUCTION
SEQUENCING AND CONSTRUCTION SEQUENCE.
2. SEE SHEETS C500 - C501 FOR STORMWATER POLLUTION
PREVENTION NOTES AND DETAILS.
SCALE: 1" = 40'
1
2
1
2
3
4
5
MINIMIZE IMPACTS
WITH FENCE REMOVAL
6
7
6
MATCHLINE: SEE SHEET C103MATCHLINE: SEE SHEET C104
MATCHLINE: SEE SHEET C101LIMITS OF WORK
SILT FENCE
CULVERT PROTECTION
STABILIZED CONSTRUCTION ENTRANCE
CONCRETE WASHOUT
TREE PROTECTION FENCE
TEMPORARY CONSTRUCTION FENCE
N
SWPP Plan
0'80'40'20'
C103
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SWPPP NOTES
SWPPP LEGEND
SCALE: 1" = 40'
1
2
3
4
5
4
24.00'150.00'1
2
MINIMIZE IMPACTS
WITH FENCE REMOVAL
1. SEE SHEET C101 FOR SWPP NOTES, PRECONSTRUCTION
SEQUENCING AND CONSTRUCTION SEQUENCE.
2. SEE SHEETS C500 - C501 FOR STORMWATER POLLUTION
PREVENTION NOTES AND DETAILS.
6
7
7
6
MATCHLINE: SEE SHEET C103 MATCHLINE: SEE SHEET C102LIMITS OF WORK
SILT FENCE
CULVERT PROTECTION
STABILIZED CONSTRUCTION ENTRANCE
CONCRETE WASHOUT
TREE PROTECTION FENCE
TEMPORARY CONSTRUCTION FENCE
N
SWPP Plan
0'80'40'20'
C104
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SWPPP NOTES
SWPPP LEGEND
SCALE: 1" = 40'
1
2
3
4
5
1
1. SEE SHEET C101 FOR SWPP NOTES, PRECONSTRUCTION
SEQUENCING AND CONSTRUCTION SEQUENCE.
2. SEE SHEETS C500 - C501 FOR STORMWATER POLLUTION
PREVENTION NOTES AND DETAILS.
3. SITE WORK DEPICTED ON THIS SHEET SHOULD BE ACCESSED FROM
THE SOUTH. EXISTING WETLAND NOT TO BE CROSSED WITH ANY
EQUIPMENT.
6
7
MATCHLINE: SEE SHEET C106
MATCHLINE: SEE SHEET C107LIMITS OF WORK
SILT FENCE
FULL DEPTH PAVEMENT AND BASE REMOVAL
TREE REMOVAL
TREE PROTECTION FENCE
REMOVE ITEM
FENCE & GATE REMOVAL
CLEARING AND GRUBBING
CLEARING AND GRUBBING WITH ROOT
PRUNING
UNDERSTORY VEGETATION CLEARING
REMOVE & SALVAGE ITEM
PROTECT ITEM
SAWCUT PAVEMENT
TEMPORARY CONSTRUCTION FENCE
SITE PREPARATION NOTES
SITE PREPARATION LEGEND
1. VERIFY ALL EXISTING CONDITIONS PRIOR TO DEMOLITION AND NOTIFY
ARCHITECT/ENGINEER OF DISCREPANCIES IN A TIMELY MANNER SO AS NOT
TO IMPACT THE CONSTRUCTION SCHEDULE. PERFORM NO WORK INVOLVING
DISCREPANCIES UNTIL DIRECTED TO DO SO BY THE ARCHITECT/ENGINEER.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF
UTILITY INFORMATION. ARCHITECT/ENGINEER MAKES NO GUARANTEE NOR
ASSUMES ANY LIABILITY AS TO THE COMPLETENESS AND/OR ACCURACY OF
UTILITY DATA.
3. ALL UTILITIES SHALL BE FIELD LOCATED A MINIMUM OF 48 HOURS PRIOR TO
THE START OF CONSTRUCTION. ANY DISCREPANCIES WITH THIS DRAWING
SHALL BE REPORTED TO THE ARCHITECT/ENGINEER IMMEDIATELY.
4. ALL STRUCTURES, UTILITIES, PAVEMENT AND TREES NOT DESIGNATED TO BE
REMOVED SHALL BE PROTECTED DURING CONSTRUCTION. ANY DAMAGE
CAUSED BY THE CONTRACTOR TO ITEMS AND STRUCTURES TO REMAIN
SHALL BE REPAIRED AT NO COST TO THE OWNER.
5. COORDINATE THE ADJUSTMENT OF UTILITY STRUCTURES WITH THE
APPROPRIATE AGENCIES. NO WORK SHALL BE DONE WITHOUT WRITTEN
CONSENT BY UTILITY OWNER. ALL UTILITY STRUCTURES TO REMAIN
INCLUDING, BUT NOT LIMITED TO: CLEAN-OUTS, MANHOLES, CATCH BASINS.
STRUCTURES, VALVE BOXES, SHUT OFF VALVES, VAULT COVERS, ELECTRIC
VAULT COVERS, ELECTRIC PULL BOXES, ECT. SHALL BE ADJUSTED TO FINISH
GRADE, UNLESS NOTED OTHERWISE.
6. ALL MATERIAL TO BE REMOVED SHALL BECOME THE PROPERTY OF THE
CONTRACTOR AND SHALL BE DISPOSED OFF SITE IN ACCORDANCE WITH ALL
STATE, LOCAL AND FEDERAL GUIDELINES. UNLESS OTHERWISE NOTED.
7. ALL STORM DRAINS AND AREA DRAINS TO RECEIVE INLET FILTER DURING
DEMOLITION. SEE SHEET C511 FOR DETAILS - REFER TO EROSION CONTROL
DRAWINGS C101-C104 FOR SEDIMENTATION CONTROL LOCATIONS.
8. INSTALL TEMPORARY FENCE WHERE INDICATED ON THE PLANS. MODIFY
PLACEMENT OF FENCE WITH ARCHITECT/ENGINEER TO ACCOMMODATE
PHASING OF CONSTRUCTION, EMERGENCY ACCESS AND PEDESTRIAN
INGRESS/EGRESS AS NECESSARY. CORING HOLES FOR POSTS IS NOT
PERMITTED IN EXISTING PAVEMENT TO REMAIN.
9. ALL CONSTRUCTION ACCESS ROADWAYS AND GRADING SHOWN SHALL BE
MAINTAINED BY THE CONTRACTOR UNTIL THE END OF CONSTRUCTION WHEN
THE ROADS SHALL BE REMOVED AND THE SITE RESTORED TO EXISTING
CONDITIONS OR FINAL SITE CONDITION AS INDICATED IN THE
CONSTRUCTION DRAWINGS..
10. CAREFULLY MAINTAIN PRESENT GRADE AT BASE OF ALL EXISTING TREES TO
REMAIN. PREVENT ANY DISTURBANCE OF EXISTING TREES. PROTECT
EXISTING TREES TO REMAIN AGAINST UNNECESSARY CUTTING, BREAKING
OR SKINNING OF ROOTS, BRUISING OF BARK, SMOTHERING TREES
STOCKPILING EXCAVATION AND CONSTRUCTION MATERIALS OR PARKING
VEHICLES WITHIN THE DRIP LINE. ANY DAMAGE BY CONTRACTOR TO
EXISTING TREES TO REMAIN SHALL BE REPAIRED/REPLACED AT NO COST TO
THE OWNER.
11. CLEANLY SAWCUT PAVEMENT AT THE JOINT CLOSEST TO WHERE INDICATED
ON DRAWINGS TO THE FULL PAVEMENT DEPTH.
12.EXISTING LANDSCAPE PLANTINGS REQUIRE CAREFUL, SELECTED REMOVALS.
TREES FOR REMOVAL WILL BE FLAGGED BY OWNER. REVIEW TREE
REMOVALS WITH ARCHITECT/ENGINEER, PRIOR TO DEMOLITION, AND
PROCEED AS DIRECTED.
13. COORDINATE STAGING, STOCKPILE ZONES, AND CONSTRUCTION FENCING WITH
THE ARCHITECT/ENGINEER PRIOR TO CONSTRUCTION.
14. ALL ASH TREES ON SITE WILL BE CLEARED BY OWNER, PRIOR TO
CONSTRUCTION.
15. DUE TO THE SENSITIVE NATURE OF THE FINE-GRAINED (CLAY) SOILS
OBSERVED AT THE SITE, TRAVEL ON THE SUBGRADES WITH CONSTRUCTION
EQUIPMENT SHOULD BE MINIMIZED.
16. CONTRACTOR SHALL PROTECT THE EXISTING CITY DUAL DUCT BANK IN THE
RIGHT -OF-WAY. IN THE EVENT OF CONFLICT WITH THE PROPOSED
IMPROVEMENTS, RELOCATION OF THE DUAL DUCT BANK AND ALL
ASSOCIATED/APPURTENANT/ANCILLARY ITEMS SHALL BE THE SOLE
RESPONSIBILITY OF THE OWNER SUBJECT TO REVIEW AND APPROVAL BY
THE CITY.
17. DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL BE RESTORED/REPAIRED
TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT.
THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH
THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE
EXISTING CONDITION OF THE RIGHT-OF-WAY.
N
Site Preparation Plan
0'80'40'20'
SCALE: 1" = 40'
C105
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
3
1
7
5
134
4
4
CULVERT PROTECTION
SEE SWPP PLANS
8 2
14
1413
14
2
3
4
5
6
7
8
11
12
13
9
10
1
14
24.00'150.00'STABILIZED CONSTRUCTION ENTRANCE
2
14
MATCHLINE: SEE SHEET C105MATCHLINE: SEE SHEET C108LIMITS OF WORK
SILT FENCE
FULL DEPTH PAVEMENT AND BASE REMOVAL
TREE REMOVAL
TREE PROTECTION FENCE
REMOVE ITEM
FENCE & GATE REMOVAL
CLEARING AND GRUBBING
CLEARING AND GRUBBING WITH ROOT
PRUNING
UNDERSTORY VEGETATION CLEARING
REMOVE & SALVAGE ITEM
PROTECT ITEM
SAWCUT PAVEMENT
TEMPORARY CONSTRUCTION FENCE
N
Site Preparation Plan
0'80'40'20'
C106
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
7
SITE PREPARATION NOTES
SITE PREPARATION LEGEND
1. SEE SHEET C105 FOR SITE PREPARATION NOTES.
SCALE: 1" = 40'
1
5
8
7
10
9
4
2
3
4
5
6
7
8
11
12
13
9
10
1
14
2
MATCHLINE: SEE SHEET C108
MATCHLINE: SEE SHEET C105LIMITS OF WORK
SILT FENCE
FULL DEPTH PAVEMENT AND BASE REMOVAL
TREE REMOVAL
TREE PROTECTION FENCE
REMOVE ITEM
FENCE & GATE REMOVAL
CLEARING AND GRUBBING
CLEARING AND GRUBBING WITH ROOT
PRUNING
UNDERSTORY VEGETATION CLEARING
REMOVE & SALVAGE ITEM
PROTECT ITEM
SAWCUT PAVEMENT
TEMPORARY CONSTRUCTION FENCE
N
Site Preparation Plan
0'80'40'20'
C107
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
6
6
6 REMOVE GARAGES
REMOVE EXISTING HOUSE AND
ALL SUBSURFACE ELEMENTS
(INCLUDING SEPTIC TANK).
BACKFILL WITH ENGINEERED FILL
REMOVE GAZEBO
REMOVE BARN
SITE PREPARATION NOTES
SITE PREPARATION LEGEND
1. SEE SHEET C105 FOR SITE PREPARATION NOTES.
SCALE: 1" = 40'
7
7
7
7
3
2
1
7
2
5
14
13
2
3
4
5
6
7
8
11
12
13
9
10
1
14
6
STABILIZED CONSTRUCTION ENTRANCE
24.00'150.00'
MATCHLINE: SEE SHEET C108MATCHLINE: SEE SHEET C107 MATCHLINE: SEE SHEET C108MATCHLINE: SEE SHEET C106LIMITS OF WORK
SILT FENCE
FULL DEPTH PAVEMENT AND BASE REMOVAL
TREE REMOVAL
TREE PROTECTION FENCE
REMOVE ITEM
FENCE & GATE REMOVAL
CLEARING AND GRUBBING
CLEARING AND GRUBBING WITH ROOT
PRUNING
UNDERSTORY VEGETATION CLEARING
REMOVE & SALVAGE ITEM
PROTECT ITEM
SAWCUT PAVEMENT
TEMPORARY CONSTRUCTION FENCE
N
Site Preparation Plan
0'80'40'20'
C108
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SITE PREPARATION NOTES
SITE PREPARATION LEGEND
1. SEE SHEET C105 FOR SITE PREPARATION NOTES.
SCALE: 1" = 40'
7
7
2
3
4
5
6
7
8
11
12
13
9
10
1
14
1
BP: 10+00.00
PC: 10+51.93
PT: 11+42.40
PC: 11+90.51
P
R
C
:
1
3
+
1
4
.
0
7
PT: 14
+
9
0.
58
PI: 15
+
3
5.
40
PI: 16
+
98.6
7
EP: 17+66.5410+00
11+00
12+00
13
+
0
0
14+00
15+0016+0017+0017+67MATCHLINE: SEE SHEET C111MATCHLINE: SEE SHEET C110
LIMITS OF WORK
ASPHALT PAVEMENT
HEAVY DUTY CONCRETE PAVEMENT
CONCRETE PAVEMENT
STABILIZED AGGREGATE TRAIL
ENGINEERED WOOD CHIP SURFACING
CONCRETE CURB AND GUTTER
CURB TRANSITION
FLUSH CURB AND GUTTER
CONCRETE BARRIER CURB
SPILLWAY
CONTROL JOINT
ISOLATION (EXPANSION) JOINT
STONE BENCH
VEHICULAR LIGHT POLE
CONCRETE WHEEL STOP
TRASH RECEPTACLE
RECYCLING CONTAINERS
BENCH
DETECTABLE WARNING STRIP
LAYOUT & MATERIALS NOTES
1.THE LAYOUT OF FACILITIES SHOWN ON THESE DRAWINGS ARE BASED
ON THE HORIZONTAL AND VERTICAL CONTROL SYSTEM ESTABLISHED
BY THE SURVEY.
2. THE LAYOUT OF TRAILS IS APPROXIMATE AND WILL BE STAKED BY
OWNER, REVIEWED AND REVISED / ADJUSTED BY ENGINEER IN ORDER
TO AVOID / PROTECT TREE OBSTRUCTIONS PRIOR TO CONSTRUCTION.
3. SITE COORDINATES ARE SHOWN FOR CONSTRUCTION BASELINES AND
KEY FEATURES ONLY. AN ELECTRONIC COPY OF AN AUTOCAD 2010
DRAWING FILE WILL BE PROVIDED TO THE SUCCESSFUL BIDDER FOR
LAYOUT OF PROPOSED FACILITIES DESIGNED BY ENGINEER AND
SHOULD BE USED ONLY FOR THOSE FACILITIES. NO GUARANTEE IS
MADE BY ENGINEER FOR THE ACCURACY OF WORK PROVIDED BY
OTHERS.
4. IN THE EVENT OF ANY DISCREPANCIES BETWEEN THESE CONTRACT
DOCUMENTS AND THE ELECTRONIC FILES, THE CONTRACT DRAWINGS
WILL CONTROL. NOTIFY THE ENGINEER IMMEDIATELY WHEN ANY
DISCREPANCY IS NOTED.
5. CONTRACTOR SHALL MAKE ADJUSTMENTS TO THE LAYOUT AS
DIRECTED BY THE ENGINEER TO ENSURE PROPER CONNECTION TO
EXISTING FACILITIES.
6. ALL DIMENSIONS MUST BE FIELD VERIFIED BY CONTRACTOR AND ANY
DISCREPANCIES REPORTED TO THE ARCHITECT/ENGINEER
IMMEDIATELY.
7. CONTRACTOR SHALL SET AUXILIARY BENCHMARKS AS REQUIRED TO
LAYOUT AND CONSTRUCT WORK.
8. CONTRACTOR TO CONFIRM LOCATION OF ALL UNDERGROUND
UTILITIES PRIOR TO START OF CONSTRUCTION.
9.PAVING RADII SHALL BE FORMED COMPLETELY AND SMOOTHLY
TRANSITION INTO TANGENTS AND ADJOINING LINES. FLAT CURVE
SEGMENTS IN HORIZONTAL LAYOUT SHALL BE REMOVED AND
REPLACED AT NO COST TO OWNER.
10.REFER TO MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES(MUTCD)
2016 EDITION FOR SIGN PANEL GUIDELINES, LAYOUT GUIDELINES, AND
REFERENCES. REFER TO INDIANA DEPARTMENT OF TRANSPORTATION
(INDOT) 2016 STANDARD SPECIFICATION SECTION 802 FOR SIGNS AND
SECTION 808 FOR PAVEMENT MARKINGS. REFER TO INDOT STANDARD
DRAWING (E 802-SNGS-05, E 802-SNGS-06) FOR SIGN
REFLECTORIZATION SCHEDULE, STANDARD DRAWING (E 802-SNGS-09,
E 802-SNGS-10) FOR STEEL SIGN POSTS SIZES AND DATA.
11. ALL PAVEMENT AREAS SHALL BE PROOF-ROLLED UNDER THE
SUPERVISION OF A GEOTECHNICAL ENGINEER, ENGAGED BY THE
CONTRACTOR FROM AN APPROVED LIST BY OWNER, PRIOR TO THE
PLACEMENT OF BASE MATERIALS AND PAVING MATERIALS.
GEOTECHNICAL ENGINEER TO DIRECT CONTRACTOR ON SUBGRADE
PREPARATION REQUIRED BASED ON FIELD OBSERVATIONS,
SPECIFICATIONS AND GEOTECHNICAL REPORT RECOMMENDATIONS.
12. HATCH PATTERNS ARE FOR REFERENCE ONLY. HATCHES DO NOT
REPRESENT DIRECTIONAL LAYOUT OR PATTERN OF MATERIALS.
CONTRACTOR SHALL PREPARE A MOCK-UP IN THE FIELD FOR
APPROVAL BY ARCHITECT/ENGINEER. REFER TO SPECIFICATIONS FOR
MOCK-UP REQUIREMENTS.
13. ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT
-OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE
DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT
THE DEPARTMENT OF ENGINEERING TO SCHEDULE A
PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S
CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION
REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF
THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS
IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED
RIGHT-OF-WAY.
N
Layout and Materials Plan
0'80'40'20'
SCALE: 1" = 40'
C109
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
LEGEND
CONCRETE PAVEMENT, TYP.
FLUSH CURB AND GUTTER, TYP.
PRECAST ARCH CULVERT
CONNECT TO EXISTING
TRAIL
HEAVY DUTY CONCRETE PAVING
22.0
0
'
TY
P
.
2
C502
5
C507
4
C502
2
C503
ENTRY CULVERT1
C507
WOOD GUARDRAIL 1
C504
PEDESTRAIN GUARDRAIL3
C504
R42.44'R545.11'SEE ENLARGEMENT
SHEET C401
SEE ENLARGEMENT
SHEET C404
CONNECT TO EXISTING
TRAIL
WOOD GUARDRAIL1
C504
LIMESTONE BOULDERS, TYP.5
C508
REPAIR EXISTING
ROADWAY ASPHALT
IMPACTED BY NEW DRIVE
INSTALLATION. SEE NOTE #13
ON THIS SHEET.
LIMITS OF WORK
MATCHLINE: SEE SHEET C109MATCHLINE: SEE SHEET C112LIMITS OF WORK
ASPHALT PAVEMENT
HEAVY DUTY CONCRETE PAVEMENT
CONCRETE PAVEMENT
STABILIZED AGGREGATE TRAIL
ENGINEERED WOOD CHIP SURFACING
CONCRETE CURB AND GUTTER
CURB TRANSITION
FLUSH CURB AND GUTTER
CONCRETE BARRIER CURB
SPILLWAY
CONTROL JOINT
ISOLATION (EXPANSION) JOINT
STONE BENCH
VEHICULAR LIGHT POLE
CONCRETE WHEEL STOP
TRASH RECEPTACLE
RECYCLING CONTAINERS
BENCH
DETECTABLE WARNING STRIP
N
Layout and Materials Plan
0'80'40'20'
C110
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
LAYOUT & MATERIALS NOTES
1. SEE SHEET C109 FOR LAYOUT AND MATERIALS NOTES.
2.SEE EXISTING CONDITIONS FOR TREE SIZE AND SPECIES.
SCALE: 1" = 40'
LEGEND
SEE ENLARGEMENT
SHEET C403
LIMITS OF WORK
900905901902903904900
900
905
897897
898
898 899899 901
901
902
902
903
903
904 904901902
903
8
9
5
9
0
0
8
9
3
8
9
4
89
6
8
9
6 897898
89
9
9
0
1
900897898899901 896 897898898899899905902
903904906907905904906905
906
905 902903904906900899901902902895
895
900
892893894
896897
898
899
901
901 89589590089289289389389489689789889989589590089
2
8
9
3
8
9
4 896897898899902903904905906
906
9059
0
6 906906
906
905906898
899
898 8999009019059049029
0
3
900
899
5.2%
25.0%
905
90
5
90290390290224.5%4.9%
900
900
897897898
898
899
899
901
901
902
903
33.3%33.3%25.0%MATCHLINE: SEE SHEET C114
MATCHLINE: SEE SHEET C1154.0:15.
8
:
1
6
.
0
:
1
w
w
w
PS
wD
co
co
co
co
D
D
co
ww
w
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED BACK OF CURB ELEV.
PROPOSED EDGE OF PAVEMENT ELEV.
PROPOSED BACK OF SIDEWALK ELEV.
GRADE BREAK LINE
SLOPE ARROW
LIMITS OF WORK
EMERGENCY OVERFLOW PATH
26.13
25
26
26.13
25
26
1.6%
B/C 26.13
E/P 26.13
B/S 26.13
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
co
w
D
PS
TS
SHEET NOTES
GRADING SYMBOLS
1.BEFORE ANY EXCAVATION ON THE SITE, CALL I.U.P.P.S. (INDIANA
UNDERGROUND PLANT PROTECTION SERVICE) @ 1-800-382-5544 TO
LOCATE ANY EXISTING UTILITIES ON THE SITE. THE CONTRACTOR
SHALL BECOME FAMILIAR WITH THE LOCATION OF ALL BURIED UTILITIES
IN THE AREAS OF WORK BEFORE STARTING OPERATIONS. THE
CONTRACTOR SHALL BE LIABLE FOR THE COST OF REPAIRING OR
REPLACING ANY BURIED CONDUIT, CABLES, OR PIPING DAMAGED
DURING THE INSTALLATION OF THIS WORK.
2.CONTRACTOR SHALL VERIFY DEPTH AND LOCATION OF EXISTING
UNDERGROUND UTILITIES AND MANHOLES PRIOR TO THE START OF
ANY SEWER CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE
ARCHITECT/ENGINEER.
3.ADJUST ALL UTILITY STRUCTURE RIMS TO MEET PROPOSED FINISH
GRADE, UNLESS NOTED OTHERWISE.
4.GRADES SHALL SLOPE TO DRAIN, BE FREE OF DEPRESSIONS OR
OTHER IRREGULARITIES AFTER COMPACTION OF SOIL AND
INSTALLATION OF PAVEMENT, AND SHALL BE UNIFORM IN SLOPE
BETWEEN THE ELEVATIONS INDICATED.
5.ALL NON-PAVED SURFACES MUST HAVE A MINIMUM GRADE OF 2%,
INCLUDING GRADING TOLERANCES. ANY STANDING WATER ON
PAVEMENT WILL REQUIRE CORRECTIVE ACTION BY THE CONTRACTOR
WITH NO COST TO THE OWNER.
6.ALL BOARDWALK AND PAVED SURFACES MUST HAVE A MINIMUM GRADE
OF 1% SLOPES ON PARKING LOT, TRAIL, PLAZA, BOARDWALK AND
WALK SURFACES SHALL NOT EXCEED 5%, INCLUDING GRADING
TOLERANCES, WITH THE EXCEPTION OF CURB RAMP LOCATIONS.
CROSS-SLOPES ON ALL PAVED SURFACES SHALL NOT EXCEED 2%,
INCLUDING GRADING TOLERANCES. ANY PROPOSED GRADES WHICH
DO NOT MEET THE AFOREMENTIONED SLOPES REQUIREMENTS SHALL
BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER PRIOR
TO CONSTRUCTION. PAVED SURFACES FOUND TO BE IN
NON-CONFORMANCE WITH SLOPE REQUIREMENTS SHALL BE
REPLACED BY THE CONTRACTOR AT NO COST TO OWNER. DIRECT
QUESTIONS OF ADA/ADAAG COMPLIANCE TO THE
ARCHITECT/ENGINEER FOR RESOLUTION.
7.FINISH GRADES SHALL MEET EXISTING AT LIMIT OF GRADING.
8.EXISTING TOPSOIL, VEGETATION AND ORGANIC MATERIALS SHALL BE
STRIPPED AND REMOVED FROM PROPOSED PAVEMENT AREAS PRIOR
TO PLACEMENT OF BASE MATERIALS.
9.FILL AREAS SHALL BE MACHINE COMPACTED IN UNIFORM LIFTS NOT
EXCEEDING 9 INCHES THICK TO 95% MAXIMUM DENSITY (MODIFIED
PROCTOR).
10.TRANSITIONS BETWEEN CURB TYPES SHALL BE 6' UNLESS OTHERWISE
NOTED.
11.FINISHED SURFACES SHALL BE SMOOTH AND EVEN WITH NO ABRUPT
OR AWKWARD CHANGES IN GRADE.
12.OWNER OR ARCHITECT/ENGINEER RESERVES THE RIGHT TO MAKE
MINOR ADJUSTMENTS IN LINES AND GRADES AS THE WORK
PROGRESSES, WHENEVER SUCH CHANGES ARE CONSIDERED
NECESSARY TO BETTER ACCOMPLISH THE DESIGN INTENT OR TO
OBTAIN A BETTER BALANCE OF CUT AND FILL. INTENT OF DESIGN IS
TO BALANCE EARTHWORK ON-SITE.
13.VERTICAL COORDINATE INFORMATION SHOWN HEREON IS
REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF 1988
(NAVD 88). VERTICAL COORDINATE INFORMATION SHOWN HEREON IS
REFERENCED TO THE NORTH AMERICAN DATUM OF 1983 (NAD83).
14.NO EXISTING 100 YEAR FLOODPLAINS, FLOODWAY FRINGES, OR
FLOODWAYS EXIST WITHIN EXISTING SITE OR EXISTING SURVEY LIMITS,
PER FEMA FIRM PANEL 18057C0205G, DATED 11/19/2014.
15.SEE SHEET C121 FOR PROPOSED DETENTION SYSTEM SUMMARY.
N
Grading Plan
0'80'40'20'
SCALE: 1"=40'
C113
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
SEE GRADING ENLARGEMENT
SHEET C408
SEE GRADING ENLARGEMENT
SHEET C407
SEE GRADING ENLARGEMENT
SHEET C405
FFE=907.00
UTILITY SYMBOLS
PROPOSED VEGETATED
FILTER STRIP WITH INFILTRATION
TRENCH (SEE SHEET C121 FOR
ADDITIONAL INFORMATION)
DETENTION BASIN
TYPICAL H.W.E.: 899.00
(SEE SHEET C121 FOR ADDITIONAL INFORMATION)
PROPOSED WET POND BMP/WET DETENTION POND
TYPICAL H.W.E.: 897.50
(SEE SHEET C121 FOR ADDITIONAL INFORMATION)
PROPOSED WET POND BMP/WET DETENTION POND
TYPICAL H.W.E.: 897.00
(SEE SHEET C121 FOR ADDITIONAL INFORMATION)
PROPOSED WET POND BMP/WET DETENTION POND
TYPICAL H.W.E.: 897.00
(SEE SHEET C121 FOR ADDITIONAL INFORMATION)
7
C514
1
STORMWATER PERMIT RESUBMIT 05/04/181
902MATCHLINE: SEE SHEET C113MATCHLINE: SEE SHEET C116S
co
co
coco
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED BACK OF CURB ELEV.
PROPOSED EDGE OF PAVEMENT ELEV.
PROPOSED BACK OF SIDEWALK ELEV.
GRADE BREAK LINE
SLOPE ARROW
LIMITS OF WORK
EMERGENCY OVERFLOW PATH
26.13
25
26
26.13
25
26
1.6%
B/C 26.13
E/P 26.13
B/S 26.13
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
co
w
D
PS
TS
N
Grading Plan
0'80'40'20'
C114
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
SHEET NOTES
GRADING SYMBOLS
1.SEE SHEET C113 FOR GRADING NOTES.
SCALE: 1" = 40'
SEE GRADING ENLARGEMENT
SHEET C407
UTILITY SYMBOLS
1
STORMWATER PERMIT RESUBMIT 05/04/181
904MATCHLINE: SEE SHEET C116
MATCHLINE: SEE SHEET C113EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED BACK OF CURB ELEV.
PROPOSED EDGE OF PAVEMENT ELEV.
PROPOSED BACK OF SIDEWALK ELEV.
GRADE BREAK LINE
SLOPE ARROW
LIMITS OF WORK
EMERGENCY OVERFLOW PATH
26.13
25
26
26.13
25
26
1.6%
B/C 26.13
E/P 26.13
B/S 26.13
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
co
w
D
PS
TS
N
Grading Plan
0'80'40'20'
SCALE: 1" = 40'
C115
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
SHEET NOTES
GRADING SYMBOLS
1.SEE SHEET C113 FOR GRADING NOTES.
UTILITY SYMBOLS
1
STORMWATER PERMIT RESUBMIT 05/04/181
1
3
4
4
6" DI
6" DIMATCHLINE: SEE SHEET C118
MATCHLINE: SEE SHEET C119900905901902903904900
900
905
897897
898
898 899899 901
901
902
902
903
903
904 904901902
903
8
9
5
9
0
0
8
9
3894
8
9
6
89
6 897898
8
9
9
9
0
1
900897898899901 896 897898898899899905902
903904906907905904906905
906
905 902903904906900899901902902895
895
900
892893894
896897
898
899
901
901 89589590089289289389389489689789889989589590089
2
8
9
3
8
94 896897898899902903904905906
906
9059
0
6 906906
906
905906898
899
898 8999009019059049029
0
3
900
899
5.2%
25.0%
905
90
5
90290390290224.5%4.9%
900
900
897897898
898
899
899
901
901
902
903
33.3%33.3%25.0%6" DI
6
5
1
8
2
LF
-
12
"
D
I
@
1
.0
1%
w
w
w
PS STM-CB-01
RIM: 905.50'
12" SE INV: 901.50'
STM-CB-02
RIM: 905.25'
12" SW INV: 901.90'
STM-CB-04
RIM: 905.25'
12" NE INV: 901.05'
12" S INV: 900.95'
48 LF - 12" PVC @ 0.83%
STM-END-01
12" N INV: 900.10'174 LF - 12" CLASS III RCP @ -0.49%STM-END-02
12" NW INV: 899.29'
STM-END-03
12" S INV: 899.00'
STM-END-04
12" N INV: 898.50'
34 LF - 12" PVC @ 0.50%
STM-END-05
12" E INV: 897.20'
STM-END-06
12" W INV: 897.00'
30 LF - 12" PVC @ 0.66%wSTM-CB-05
RIM: 903.89'
12" SW INV: 900.14'
D 147 LF - 12"
DI
@ 0.33
%
STM-CB-06
RIM: 901.63'
12" S INV: 897.88'
STM-END-09
12" N INV: 897.05'
156 LF - 12" PVC @ 0.33%
STM-END-07
12" E INV: 897.00'
STM-END-08
12" SW INV: 896.73'
15 LF - 12" DI @ 0.54%
STM-MH-01
RIM: 904.09'
12" NW INV: 899.65'
12" NE INV: 899.65'
12" SE INV: 899.55'
STM-CB-03
RIM: 905.50'
12" NE INV: 901.50'
12" SW INV: 901.40'
45 LF - 12" PVC @ 0.78%
6
5
L
F
-
1
2
"
C
L
A
S
S
I
I
I
R
C
P
@
0
.
4
0%
STM-CB-07
RIM: 901.11'
12" N INV: 897.36'
12" S INV: 897.26'
64 LF - 12" DI @ 0.33%
STM-END-11
(2) W INV. 897.31 STM-END-12
(2) E INV. 896.83
(2) 48 LF - 14"x23" ELLIPTICAL RCP @ 1.00%
co
co
co
co
D
STM-RESTRICTOR-01
RIM: 903.83'
12" N INV: 898.83'
12" S INV: 898.73'
D
STM-RESTRICTOR-02
RIM: 900.91'
12" W INV: 896.92'
12" NE INV: 896.82'
47 LF - 12" PVC @ 0.49%
16 LF - 12" DI @ 0.57%46 LF - 12" PVC @ 0.66%STM-END-11
12" N INV: 901.20'
STM-END-10
12" S INV: 901.50'
co
ww
w
8
6" DI6" DI6"
D
I
7
1
9
10
6"
D
I6" DI6
"
D
I
6" DI6" DI112 LF -
6"
P
V
C
@
1.0
%
12
13
15
14
16
15
16
16
16
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
co
w
D
PS
TS
SCHEMATIC GAS LINE ROUTING SHOWN. FINAL SIZING, DESIGN, AND
INSTALLATION TO BE PER VECTREN. CONTRACTOR TO
COORDINATE FORMAL DESIGN AND SITE READY DATE FOR VECTREN
INSTALLATION. OWNER TO DIRECTLY PAY VECTREN FOR SERVICE
INSTALLATION, AS APPLICABLE.
EXISTING SANITARY MANHOLE. DIRECT FORCE MAIN CONNECTION
INTO FLOWLINE IN THE DOWNSTREAM DIRECTIONS. SEE DETAIL 3
SHEET C512.
GRINDER PUMP STATION. SEE DETAIL 1 SHEET C510.
2" WATER METER TO BE LOCATED INSIDE BUILDING. PLUMBING
PLANS TO BE SUBMITTED WITH ARCHITECTURAL PERMIT SET.
WET TAP ON 16" PVC WATER MAIN.
JACK-AND-BORE 14" DI CASING PIPE UNDER 116TH STREET, 60 LF.
INSTALL PROPOSED 6" DI WATER MAIN THROUGH CASING PIPE IN
ACCORDANCE WITH INDOT STANDARD SPECIFICATIONS, SECTION
716.
FIRE HYDRANT ASSEMBLY.
FIRE HYDRANT ASSEMBLY. FIRE-DEPARTMENT CONNECTION TO BE
LOCATED NEARBY BY ARCHITECT.
PRECAST CONCRETE ARCH CULVERT, SEE DETAIL 1, SHEET C507.1
ENTRANCE CULVERT, SEE DETAIL 1, SHEET C507
ALL STORM SEWER DAYLIGHTS TO PROPOSED BASINS AND DITCHES
TO TERMINATE WITH PRECAST CONCRETE FLARED END-SECTIONS
WITH RIPRAP BEDDING, SEE UTILITY DETAILS, SHEET C511.
HORIZONTAL DIRECTIONAL DRILL TO SANITARY MANHOLE, 767 LF.
THREE TRACER WIRES SHALL BE INSTALLED ALONG ALL
DIRECTIONALLY DRILLED PIPE. ALL TRACE WIRE TERMINATION
POINTS MUST UTILIZE A TRACER WIRE ACCESS STATION. SEE
DETAIL 4, SHEET 512 FOR MATERIAL SPECIFICATIONS AND ACCESS
STATION DETAIL.
AIR COMPRESSOR AND COMPRESSOR CABINET, TO BE KEETON
INDUSTRIES QUIETLINE KR-4DP (1/2 HP COMPRESSOR, 50 PSI MAX
PRESSURE, 115V. WITH ALL-WEATHER TAN COLOR CABINET WITH
SOUND-REDUCTION PACKAGE AND A.S.T.M.-RATED FOAM, AND BLUE
ANODIZED ALUMINUM 4 VALVE COOLING MANIFOLD) OR EQUIVALENT
TO BE APPROVED BY ENGINEER.
KEETON INDUSTRIES RM-4 REMOTE DISTRIBUTION MANIFOLD
ENCLOSED IN 19" X 14" X 7.5" IRRIGATION VALVE BOX, OR
EQUIVALENT TO BE APPROVED BY ENGINEER.
DIRECT-BURY COMPRESSED AIR TUBING. TUBING FROM
COMPRESSOR CABINET TO REMOTE MANIFOLD TO BE 3/4" POLYPIPE
FLEXIBLE TUBING AT 3' MINIMUM COVER. TUBING FROM REMOTE
MANIFOLD TO DIFFUSER UNITS TO BE KEETON INDUSTRIES
SELF-WEIGHTED FEEDER TUBING (0.50" INSIDE DIA. x 1.00" OUTSIDE
DIA.) AT 3' MINIMUM COVER, OR EQUIVALENT TO BE APPROVED BY
ENGINEER.
KEETON INDUSTRIES DURAPLATE MEMBRANE DIFFUSOR, OR
EQUIVALENT TO BE APPROVED BY ENGINEER.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
1.WATER MAINS TO HAVE 4.5 FEET OF COVER MINIMUM.
2.SANITARY FORCE MAIN TO HAVE 4.5 FT OF COVER MINIMUM.
3.ALL WATER LINES TO BE INSTALLED WITH TRACER WIRE AND BLUE
REFLECTIVE WARNING TAPE LOCATED 18" ABOVE WATER LINE.
4.THE STORM SEWER SYSTEM SHALL BE CONSTRUCTED PER DESIGN
SPECIFIED AND AS APPROVED BY THE CITY OF CARMEL ON THE FINAL
APPROVED CONSTRUCTION PLANS. DEVIATIONS FROM THE APPROVED
DESIGN SHALL ONLY BE PERMITTED DUE TO SPECIAL CIRCUMSTANCES
OR DIFFICULTY DURING CONSTRUCTION AND WILL REQUIRE PRIOR
FIELD APPROVAL FROM A DESIGNATED REPRESENTATIVE OF THE CITY
OF CARMEL IN ADDITION TO SUPPLEMENTAL APPROVAL BY THE DESIGN
ENGINEER. AN EXPLANATION OF ANY SUCH DEVIATION SHALL BE
INCLUDED AS A REQUIREMENT ON AS-BUILT/RECORD DRAWINGS
SUBMITTED FOR RELEASE OF PERFORMANCE GUARANTEES.
APPROVED DESIGN SLOPES IDENTIFIED AS GENERATING VELOCITIES
OF 2.5 FPS OR LESS OR 10 FPS OR GREATER (AT FULL FLOW CAPACITY)
SHALL REQUIRE AS-BUILT CERTIFICATION AT THE TIME OF
CONSTRUCTION, PRIOR TO BACKFILLING THE PIPE. THE CONTRACTOR
IS INSTRUCTED TO AS-BUILT EACH SECTION OF STORM PIPE AS IT IS
BEING INSTALLED TO ENSURE COMPLIANCE WITH THE DESIGN PLANS
AND AS APPROVED BY THE CITY OF CARMEL.
5.PROPOSED STORMWATER MANAGEMENT SYSTEM IS TO BE UNDER THE
PRIVATE OWNERSHIP OF THE OWNER.
6.VERTICAL COORDINATE INFORMATION SHOWN HEREON IS
REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM OF 1988
(NAVD 88).
7.NO EXISTING 100 YEAR FLOODPLAINS, FLOODWAY FRINGES, OR
FLOODWAYS EXIST WITHIN EXISTING SITE OR EXISTING SURVEY LIMITS,
PER FEMA FIRM PANEL 18057C0205G, DATED 11/19/2014.
8.SEE SHEET C121 FOR PROPOSED DETENTION SYSTEM SUMMARY.
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
SHEET NOTES
UTILITY SYMBOLS
N
Utilities Plan
0'80'40'20'
SCALE: 1" = 40'
C117
DESCRIPTIVE KEYED NOTES
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
PROPOSED VEGETATED
FILTER STRIP WITH INFILTRATION
TRENCH (SEE SHEET C121 FOR
ADDITIONAL INFORMATION)
7
C514
122 LF - 6" PERFORATED
HDPE UNDERDRAIN @ 0.5%
3
C510
55 LF - 6" HDPE @ 1.0%
6" W INV: 898.40'
EXISTING POND TYPICAL H.W.E.: 895.5±
STRUCTURE
NAME
RIM
ELEVATION
FRAME AND
GRATE TYPE
STRUCTURE
DIAMETER
STRUCTURE TABLE
STM-CB-01 905.50 NEENAH
R-2548
2.0'
STRUCTURE
CONNECTIONS
SE 12" INV. 901.50
STM-CB-02 905.25 NEENAH
R-2548
2.0'SW 12" INV. 901.90
STM-CB-03 905.50 NEENAH
R-2548
2.0'NE 12" INV. 901.50
SW 12" INV. 901.40
STM-CB-04 905.25 NEENAH
R-2548
2.0'NE 12" INV. 901.05
SW 12" INV. 900.95
903.89 NEENAH
R-3501-N
2.0'SW 12" INV. 900.14
STM-CB-06 901.63 NEENAH
R-2548
2.0'W 6" INV. 898.40
S 12" INV. 897.88
STM-CB-07 901.11 NEENAH
R-2548
2.0'N 12" INV. 897.36
S 12" INV. 897.26
STM-MH-01 904.09 NEENAH
R-1642A
4.0'NW 12" INV. 900.65
NE 12" INV. 900.65
SE 12" INV. 900.55
DETENTION BASIN
TYPICAL H.W.E.: 899.00
(SEE SHEET C121 FOR ADDITIONAL INFORMATION)
PROPOSED WET POND BMP/WET DETENTION POND
TYPICAL H.W.E.: 897.50
(SEE SHEET C121 FOR ADDITIONAL INFORMATION)
PROPOSED WET POND BMP/WET DETENTION POND
TYPICAL H.W.E.: 897.00
(SEE SHEET C121 FOR ADDITIONAL INFORMATION)
PROPOSED WET POND BMP/WET DETENTION POND
TYPICAL H.W.E.: 897.00
(SEE SHEET C121 FOR ADDITIONAL INFORMATION)
FLOW RESTRICTOR
FLOW RESTRICTOR
FIRE-DEPARTMENT CONNECTION
DRINKING FOUNTAIN (SEE PLUMBING
DRAWING FOR SERVICE CONNECTIONS)
UTILITY CROSSING
(NATURAL GAS LINE)
UTILITY CROSSING
(WATER MAIN, MAINTAIN
18" VERTICAL CLEAR
DISTANCE BETWEEN
STORM SEWER AND
WATER MAIN)
26 LF - 6" PVC @ 1.0%
(SEE PLUMBING DRAWING
FOR CONTINUATION)
3
.
0
0
'
BORING PIT
BORING PIT
STM-CB-05
STM-RESTRICTOR-01 903.83 NEENAH
R-1642A
4.0'N 12" INV. 898.83
S 12" INV. 898.73
STM-RESTRICTOR-02 900.91 NEENAH
R-1642A
4.0'W 12" INV. 896.92
E 12" INV. 896.82
BUILDING DOWNSPOUT
LOCATION
CONVEYANCE WEIR
REINFORCEMENT
8
C508
BUILDING DOWNSPOUT
LOCATION
UPSTREAM DOWNSTREAM UPSTREAM DOWNSTREAM LENGTH MATERIAL D (IN)
STRUCTURE STRUCTURE INVERT INVERT (FEET)
STM-CB-01 STM-MH-01 901.50 899.65 182 DI 12
STM-CB-02 STM-CB-03 901.90 901.50 48 PVC 12
STM-CB-03 STM-CB-04 901.40 901.05 45 PVC 12
STM-CB-04 STM-END-01 900.95 900.10 174 RCP 12
STM-CB-05 STM-MH-01 900.14 899.65 147 DI 12
STM-MH-01 STM-END-02 899.55 899.29 65 RCP 12
STM-END-10 STM-END-11 901.50 901.20 46 PVC 12
STM-END-03 STM-RESTRICTOR-01 899.00 898.83 34 PVC 12
STM-RESTRICTOR-01 STM-END-04 898.83 898.50 47 PVC 12
STM-END-05 STM-END-06 897.20 897.00 30 PVC 12
STM-END-07 STM-RESTRICTOR-02 897.00 896.92 15 PVC 12
STM-RESTRICTOR-02 STM-END-08 896.82 896.73 16 PVC 12
STM-CB-06 STM-CB-07 897.88 897.36 156 PVC 12
STM-CB-07 STM-END-09 897.26 897.05 64 DI 12
STM-END-10 STM-END-11 897.31 896.83 48 RCP 14X23 (2)
DETAIL
REFERENCE
C511, 1
C511, 1
C511, 1
C511, 1C511, 1
C511, 1
C511, 1
C511, 1
C511, 2
C511, 6
C511, 6
6"X21
2" DI REDUCER (DOMESTIC SERVICE)
6"X4" DI REDUCER
1
STORMWATER PERMIT RESUBMIT 04/13/18
2
1
1
1
1
6"X4" DI REDUCER (FIRE SERVICE)
MUELLER 6" POST-INDICATOR VALVE WITH ADJUSTIBLE
INDICATOR POST, OR EQUIVALENT TO BE APPROVED
BY ENGINEER
6"X6" DI TEE
STORMWATER PERMIT RESUBMIT 05/04/18
2
2" HDPE DR11 FORCE MAIN2
MATCHLINE: SEE SHEET C117MATCHLINE: SEE SHEET C120902S
co
co
coco
12
SCHEMATIC GAS LINE ROUTING SHOWN. FINAL SIZING, DESIGN, AND
INSTALLATION TO BE PER VECTREN. CONTRACTOR TO
COORDINATE FORMAL DESIGN AND SITE READY DATE FOR VECTREN
INSTALLATION. OWNER TO DIRECTLY PAY VECTREN FOR SERVICE
INSTALLATION, AS APPLICABLE.
EXISTING SANITARY MANHOLE. DIRECT FORCE MAIN CONNECTION
INTO FLOWLINE IN THE DOWNSTREAM DIRECTIONS. SEE DETAIL 3
SHEET C512.
GRINDER PUMP STATION. SEE DETAIL 1 SHEET C510.
2" WATER METER TO BE LOCATED INSIDE BUILDING. PLUMBING
PLANS TO BE SUBMITTED WITH ARCHITECTURAL PERMIT SET.
WET TAP ON 16" PVC WATER MAIN.
JACK-AND-BORE 14" DI CASING PIPE UNDER 116TH STREET, 60 LF.
INSTALL PROPOSED 6" DI WATER MAIN THROUGH CASING PIPE IN
ACCORDANCE WITH INDOT STANDARD SPECIFICATIONS, SECTION
716.
FIRE HYDRANT ASSEMBLY.
FIRE HYDRANT ASSEMBLY. FIRE-DEPARTMENT CONNECTION TO BE
LOCATED NEARBY BY ARCHITECT.
PRECAST CONCRETE ARCH CULVERT, SEE DETAIL 1, SHEET C507.1
ENTRANCE CULVERT, SEE DETAIL 1, SHEET C507
ALL STORM SEWER DAYLIGHTS TO PROPOSED BASINS AND DITCHES
TO TERMINATE WITH PRECAST CONCRETE FLARED END-SECTIONS
WITH RIPRAP BEDDING, SEE UTILITY DETAILS, SHEET C511.
HORIZONTAL DIRECTIONAL DRILL TO SANITARY MANHOLE, 767 LF.
THREE TRACER WIRES SHALL BE INSTALLED ALONG ALL
DIRECTIONALLY DRILLED PIPE. ALL TRACE WIRE TERMINATION
POINTS MUST UTILIZE A TRACER WIRE ACCESS STATION. SEE
DETAIL 4, SHEET 512 FOR MATERIAL SPECIFICATIONS AND ACCESS
STATION DETAIL.
AIR COMPRESSOR AND COMPRESSOR CABINET, TO BE KEETON
INDUSTRIES QUIETLINE KR-4DP (1/2 HP COMPRESSOR, 50 PSI MAX
PRESSURE, 115V. WITH ALL-WEATHER TAN COLOR CABINET WITH
SOUND-REDUCTION PACKAGE AND A.S.T.M.-RATED FOAM, AND BLUE
ANODIZED ALUMINUM 4 VALVE COOLING MANIFOLD) OR EQUIVALENT
TO BE APPROVED BY ENGINEER.
KEETON INDUSTRIES RM-4 REMOTE DISTRIBUTION MANIFOLD
ENCLOSED IN 19" X 14" X 7.5" IRRIGATION VALVE BOX, OR
EQUIVALENT TO BE APPROVED BY ENGINEER.
DIRECT-BURY COMPRESSED AIR TUBING. TUBING FROM
COMPRESSOR CABINET TO REMOTE MANIFOLD TO BE 3/4" POLYPIPE
FLEXIBLE TUBING AT 3' MINIMUM COVER. TUBING FROM REMOTE
MANIFOLD TO DIFFUSER UNITS TO BE KEETON INDUSTRIES
SELF-WEIGHTED FEEDER TUBING (0.50" INSIDE DIA. x 1.00" OUTSIDE
DIA.) AT 3' MINIMUM COVER, OR EQUIVALENT TO BE APPROVED BY
ENGINEER.
KEETON INDUSTRIES DURAPLATE MEMBRANE DIFFUSOR, OR
EQUIVALENT TO BE APPROVED BY ENGINEER.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
co
w
D
PS
TS
N
Utilities Plan
0'80'40'20'
C118
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
SCALE: 1" = 40'
SHEET NOTES
DESCRIPTIVE KEYED NOTES
A.SEE SHEET C117 FOR UTILITY NOTES
279 LF - 6" DUAL-WALLED PERFORATED HDPE UNDERDRAIN @ 0.2%
140 LF - 6" PVC @ 0.5%
DAYLIGHT DRAIN,
INV.: 900.80
UNDERDRAIN INV.: 901.50
UNDERDRAIN INV.: 902.05 UTILITY SYMBOLS
ISSUED FOR CONSTRUCTION 04/02/18
1
1
279 LF - 6" DUAL-WALLED PERFORATED HDPE UNDERDRAIN @ 0.2%
STORMWATER PERMIT RESUBMIT 05/04/18
900905901902903904900
900
905
897897898
898 899899
901
901
902
902 903903
904 904901902
903
8
9
5
9
0
0
8
9
3894 896
8
9
6 897898
8
9
9
9
0
1
900897898899901 896 897898898899899905902
903904906907905904906905
906
905 902903904906900899901902902895
895
900
892893894
896897
898
899
901
901 89589590089289289389389489689789889989589590089
2
8
9
3894 896897898899902903904905906
906
9059
0
6 906906
906
905906898
899
898 8999009019059049029
0
3
900
899
5.2%
25.0%
905
90
5
90290390290224.5%4.9%
900
900
897897
898
898
899
899
901
901
902
903
33.3%33.3%25.0%w
w
w
PS
wD
co
co
co
co
D
D
co
ww
w
112 LF -
6"
P
V
C
@
1.0
%
25.0%
33.0%17.8%14.8
%24.5%23.0%19.0%24
.
9%18.1%25.0%33.3%33.3%25.0%25.0%
25
.
0
%
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
co
w
D
PS
TS
1.POND 1P IS DESIGNED TO MEET THE CITY OF CARMEL'S
STANDARDS FOR A DRY-BOTTOM DETENTION BASIN,
ALTHOUGH BASIN BOTTOM WILL BE LANDSCAPED IN A
MANNER SIMILAR TO THE CITY OF CARMEL'S CONSTRUCTED
WETLAND STANDARDS. THIS LANDSCAPED AREA IS TO BE A
SITE FEATURE CONSTRUCTED FOR AESTHETIC PURPOSES,
AND DUE TO ITS LACK OF A DEFINED PERENNIAL SOURCE OF
BASE FLOW, IS NOT COUNTED AS CREDIT TOWARDS WATER
QUALITY REQUIREMENTS.
2.VERTICAL COORDINATE INFORMATION SHOWN HEREON IS
REFERENCED TO THE NORTH AMERICAN VERTICAL DATUM
OF 1988 (NAVD 88).
3.NO EXISTING 100 YEAR FLOODPLAINS, FLOODWAY FRINGES,
OR FLOODWAYS EXIST WITHIN EXISTING SITE OR EXISTING
SURVEY LIMITS, PER FEMA FIRM PANEL 18057C0205G, DATED
11/19/2014.
4.MINIMUM FLOOD PROTECTION GRADE: 906.78 (DEFINED BY
LOCAL INLET (CB-02, CB-03, CB-04) CLOGGED OVERFLOW
H.W.E. ELEVATION.
5.LOWEST PROPOSED ADJACENT STRUCTURE GRADE: 907.00
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED BACK OF CURB ELEV.
PROPOSED EDGE OF PAVEMENT ELEV.
PROPOSED BACK OF SIDEWALK ELEV.
GRADE BREAK LINE
SLOPE ARROW
LIMITS OF WORK
EMERGENCY OVERFLOW PATH
26.13
25
26
26.13
25
26
1.6%
B/C 26.13
E/P 26.13
B/S 26.13
POND NORMAL HIGH-WATER ELEVATION
EMERGENCY OVERFLOW HIGH-WATER ELEVATION
(CLOGGED CONDITION, 100-YEAR EVENT)
DESIGN EVENT HIGH-WATER ELEVATION
OVERFLOW WEIR FLOW PATH
PROPOSED DETENTION EASEMENT
PROPOSED BMP EASEMENT
PROPOSED ACCESS EASEMENT
SHEET NOTES
UTILITY SYMBOLS
N
Detention Plan
0'80'40'20'
SCALE: 1" = 40'
C121
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
POND 3P
PROPOSED VEGETATED
FILTER STRIP WITH INFILTRATION
TRENCH
BOTTOM OF STORAGE MEDIA: 902.20
7
C514
EXISTING POND TYPICAL H.W.E.: 895.5±
POND 1P DRY-BOTTOM DETENTION BASIN (SEE NOTE 1)
TYPICAL H.W.E.: 899.00
BOTTOM OF ARCHITECTURAL WETLAND: 897.00
POND 1P DRY-BOTTOM DETENTION BASIN (SEE NOTE 1)
AREA TREATED -- 3.24 AC.PROV. VOLUME @ WEIR ELEV: 0.93 AF
6" ORIFICE @ ELEV. 898.73 WEIR @ EL. 903.10, TOP OF BANK EL. 904.00
FREQ.
INFLOW ALLOWABLE PROPOSED HWE VOL.
(CFS)OUTFLOW OUTFLOW ELEV.REQUIRED
(CFS) (SEE
NOTE 2)(CFS)(AF)
2-YEAR 10.2 N/A 1.1 900.42 0.19
10-YEAR 16.1 N/A 1.4 901.13 0.335
100-YEAR 29.2 N/A 1.8 902.39 0.699
POND 2P WET-BOTTOM DETENTION BASIN
AREA TREATED -- 6.10 AC.PROV. VOLUME @ WEIR ELEV: 1.53 AF
6" ORIFICE @ ELEV. 897.00 WEIR @ EL. 899.40, TOP OF BANK EL. 900.90
FREQ.
INFLOW ALLOWABLE PROPOSED HWE VOL.
(CFS)OUTFLOW OUTFLOW ELEV.REQUIRED
(CFS)(CFS)(AF)
2-YEAR 7.3 0.61 0.7 897.8 0.373
10-YEAR 12.5 0.61 0.9 898.23 0.646
100-YEAR 24.5 1.83 1.3 899.14 1.319
POND 3P VEGETATED STRIP AND INFILTRATION TRENCH
AREA TREATED -- 0.22 AC.VOLUME PROV. @ WEIR ELEV: 0.03 af
NO ORIFICE WEIR @ EL. 905.20
FREQ.
INFLOW ALLOWABLE PROPOSED HWE VOL.
(CFS)OUTFLOW OUTFLOW ELEV.REQUIRED
(CFS)(CFS)(AF)
2-YEAR 0.6 0.02 0 904.85 0.027
10-YEAR 1 0.02 0.1 905.21 0.03
100-YEAR 1.9 0.06 1.9 905.3 0.03
GRADING SYMBOLS
DETENTION POND SYMBOLS
POND 1P 2-YEAR H.W.E.: 900.42
POND 1P 10-YEAR H.W.E.: 901.13
POND 1P 100-YEAR H.W.E.: 902.39
POND 1P CLOGGED CONDITION 100-YEAR H.W.E.: 903.77
POND 2P WET DETENTION POND, SUB-POND B
TYPICAL H.W.E.: 897.00
BOTTOM OF POND ELEV.: 892.00
POND 2P 2-YEAR H.W.E.: 897.80
POND 2P 10-YEAR H.W.E.: 898.23
POND 2P 100-YEAR H.W.E.: 899.14
POND 1P CLOGGED CONDITION 100-YEAR H.W.E.: 899.80
POND 2P WET DETENTION POND, SUB-POND A
TYPICAL H.W.E.: 897.00
BOTTOM OF POND ELEV.: 892.00
POND 2P 2-YEAR H.W.E.: 897.80
POND 2P 10-YEAR H.W.E.: 898.23
POND 2P 100-YEAR H.W.E.: 899.14
POND 2P WET DETENTION POND, SUB-POND C
TYPICAL H.W.E.: 897.50
BOTTOM OF POND ELEV.: 893.00
POND 2P WET DETENTION POND, SUB-POND A
TYPICAL H.W.E.: 897.00
BOTTOM OF POND ELEV.: 892.00
POND 2P 2-YEAR H.W.E.: 897.80
POND 2P 10-YEAR H.W.E.: 898.23
POND 2P 100-YEAR H.W.E.: 899.14
POND 1P RESTRICING STRUCTURE
6" ORIFICE, INV.: 898.73
POND 2P RESTRICING STRUCTURE
6" ORIFICE, INV.: 897.00
POND 1P OVERFLOW WEIR
ELEV: 903.10
LENGTH: 22 FT
BREADTH: 20 FT
POND 2P OVERFLOW WEIR
ELEV: 899.40
LENGTH: 80 FT
BREADTH: 10 FT
POND 3P OVERFLOW WEIR
ELEV: 905.20
LENGTH: 22 FT
BREADTH: 1 FT
POND 2P INTERNAL CONVEYANCE WEIR
ELEV: 897.60
LENGTH: 40 FT
BREADTH: 10 FT
POND 2P INTERNAL OVERFLOW WEIR
ELEV: 900.10
LENGTH: 48 FT
BREADTH: 6 FT
100-YEAR DESIGN H.W.E. (SEE PLAN)
NOT TO SCALE
DETENTION POND TYPICAL SECTION1
1V:4H M
A
X
.
10' SAFETY
SHELF 1V:3H
M
A
X
.
2'
VARIES (SEE PLAN)
2' MAX.
VARIES (SEE PLAN)
NORMAL POOL H.W.E. (SEE PLAN)
MINIMUM FLOOD PROTECTION
GRADE
1
STORMWATER PERMIT RESUBMIT 04/13/181
FILTER STRIP BMP EASEMENT (25' HORIZONTALLY
ALONG LENGTH OF PAVEMENT SIDE)
DETENTION EASEMENT (15' HORIZONTALLY FROM PROVIDED TOP-OF-BANK ELEVATION)
WET POND BMP EASEMENT (25' HORIZONTALLY ALONG PERIMETER OF BMP)
VEGETATED FILTER STRIP BMP ACCESS EASEMENT (20' WIDE MINIMUM TO PUBLIC R.O.W.)
SHARED DETENTION/BMP ACCESS EASEMENT (20' WIDE MINIMUM TO PUBLIC R.O.W.)
LOCAL INLET OVERFLOW WEIR
(CB-02, CB-03, CB-04)
ELEV: 906.55
LENGTH: 11.3 FT
BREADTH: 5 FT
100-YEAR CLOGGED HWE: 906.77
LOCAL INLET
OVERFLOW WEIR
(CB-01)
ELEV: 906.00
LENGTH: 7 FT
BREADTH: 5 FT
100-YEAR CLOGGED HWE: 906.13
STORMWATER PERMIT RESUBMIT 05/04/18
2
2
VEGETATED SWALE
(NOT COUNTED TOWARDS
WATER-QUALITY CREDIT)
VEGETATED SWALE
(NOT COUNTED TOWARDS
WATER-QUALITY CREDIT)
BP: 10+00.00
PC: 10+51.93
PT: 11+42.40
PC: 11+90.51
P
R
C
:
1
3
+
1
4
.
0
7
PT: 14
+
9
0.
58
PI: 15
+
3
5.
40
PI: 16
+
98.6
7
EP: 17+66.5410+00
11+00
12+00
13
+
0
0
14+00
15+0016+0017+0017+67N
Fire Truck Access Plan - Arrival
0'80'40'20'
SCALE: 1" = 40'
C122
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
CITY OF CARMEL
FIRE TRUCK TURNING PATH (TYP.)
22.0
0
'
TY
P
.R42.44'R545.11'NOT TO SCALE
CITY OF CARMEL FIRE TRUCK DIMENSIONAL EXHIBIT1
BP: 10+00.00
PC: 10+51.93
PT: 11+42.40
PC: 11+90.51
P
R
C
:
1
3
+
1
4
.
0
7
PT: 14
+
9
0.
58
PI: 15
+
3
5.
40
PI: 16
+
98.6
7
EP: 17+66.5410+00
11+00
12+00
13
+
0
0
14+00
15+0016+0017+0017+67N
Fire Truck Access Plan
-Departure
0'80'40'20'
SCALE: 1" = 40'
C123
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
CITY OF CARMEL
FIRE TRUCK TURNING PATH (TYP.)
22.0
0
'
TY
P
.R42.44'R545.11'NOT TO SCALE
CITY OF CARMEL FIRE TRUCK DIMENSIONAL EXHIBIT1
LIMITS OF WORK
EXISTING TREES
DECIDUOUS TREE
ORNAMENTAL TREE
EVERGREEN TREE
DECIDUOUS SHRUBS
EVERGREEN SHRUBS
PERENNIALS / GRASSES
UPLAND SEED MIX
WET/MESIC SEED MIX
WOODLAND SEED MIX
SOD
EXISTING WETLAND BOUNDARY
OPEN WATER
MATCHLINE: SEE SHEET C126
MATCHLINE: SEE SHEET C128LANDSCAPE NOTES
LANDSCAPE SYMBOLS
1.THE LAYOUT OF ALL PLANTING BEDS AND INDIVIDUAL TREES SHALL BE
STAKED BY THE CONTRACTOR IN ADVANCE OF INSTALLATION.
FLAGGING, STAKES, OR PAINT MAY BE USED TO DELINEATE LOCATIONS
AS SCALED FROM THE PLANS. THE LANDSCAPE ARCHITECT WILL
REVIEW THESE LOCATIONS WITH THE CONTRACTOR AND MAKE MINOR
ADJUSTMENTS AS NECESSARY. BED LAYOUT SHALL ALSO INCLUDE
PERENNIAL GROUPINGS BY SPECIES.
2.THE CONTRACTOR IS RESPONSIBLE FOR INDEPENDENTLY
DETERMINING THE PLANT MATERIAL QUANTITIES REQUIRED BY THE
LANDSCAPE PLANS. REPORT DISCREPANCIES TO THE LANDSCAPE
ARCHITECT.
3.PROVIDE FINE GRADING AND SOIL PREPARATION FOR ALL SEEDING
AREAS AND PLANTING BEDS PER SPECIFICATIONS. TOPSOIL DEPTH IN
TURF SEED MIX AREAS SHALL BE A MINIMUM OF 12". PRAIRIE AND
BIOSWALE SEED MIX AREAS SHALL HAVE A MINIMUM TOPSOIL DEPTH
OF 18".
4.SEE SWPP PLANS FOR TYPE & LOCATION OF EROSION CONTROL
MEASURES.
5.SEEDING AND PLUG PLANTING SHALL OCCUR IN DESIGNATED PLANTING
WINDOWS, PER SPECIFICATIONS.
6.EXTENDED MAINTENANCE APPLIES TO ALL NATIVE SEEDING AND PLUG
PLANTING. REFER TO SPECIFICATIONS.
7.REFER TO CIVIL C-SHEETS FOR GRADING, STORM UTILITIES,
HARDSCAPE PAVING AND WALKS, CURBING, SITE PREPARATION, AND
TOPSOIL PLACEMENT WORK.
8.PAINT OR STAKE SEEDING LIMITS FOR REVIEW BY LANDSCAPE
ARCHITECT PRIOR TO SEEDING.
9.OUTER LIMITS OF SEEDING ARE APPROXIMATE AND SHALL APPLY TO
ALL AREAS DISTURBED BY CONSTRUCTION ACTIVITIES.
10.ALL PLANTED TREES AND SHRUBS INDICATED TO RECEIVE MULCH ON
THE DRAWINGS AND DETAILS SHALL RECEIVE 3" DEPTH OF MULCH AS
DEFINED IN THE SPECIFICATIONS.
11.SEE DETAIL #8, SHEET C514, FOR NATIVE SEEDING SIGNAGE
REQUIREMENTS.
N
Landscape Plan
0'80'40'20'
SCALE: 1" = 40'-0"
C125
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
UPLAND SEED MIX, TYP.
WET/MESIC SEED MIX, TYP.
SEE SHEET C409 FOR LANDSCAPE ENLARGEMENT
SOD, TYP.
(1) TD
(1) COV
(1) QM(1) AG
(1) QM
(1) TD
(1) PO
(1) PO
(1) BN(1) QA
(1) COV
(1) GD
(1) AG
LIMITS OF WORK
LIMITS OF WORK
SEE SHEET C411
SEE SHEET C410
WET/MESIC SEED MIX, TYP.
NATIVE SEEDING LIMITS SIGN, TYP.
INSTALL AT 150' O.C. MAXIMUM AROUND
PERIMETER OF PEDESTRIAN AREAS
WHERE ADJACENT TO NATIVE SEEDING,
AS SHOWN.
8
C514
(1) QM
STORMWATER PERMIT RESUBMIT 05/04/18
1
1
MATCHLINE: SEE SHEET C125
LIMITS OF WORK
EXISTING TREES
DECIDUOUS TREE
ORNAMENTAL TREE
EVERGREEN TREE
DECIDUOUS SHRUBS
EVERGREEN SHRUBS
PERENNIALS / GRASSES
UPLAND SEED MIX
WET/MESIC SEED MIX
WOODLAND SEED MIX
SOD
EXISTING WETLAND BOUNDARY
OPEN WATER
LANDSCAPE NOTES
A.SEE SHEET C125 FOR LANDSCAPE NOTES.
N
Landscape Plan
0'80'40'20'
SCALE: 1" = 40'-0"
C126
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
LANDSCAPE SYMBOLS
WOODLAND SEED MIX, TYP.
NATIVE SEEDING LIMITS SIGN, TYP.
INSTALL AT 150' O.C. MAXIMUM AROUND
PERIMETER OF PEDESTRIAN AREAS
WHERE ADJACENT TO NATIVE SEEDING,
AS SHOWN.
8
C514
STORMWATER PERMIT RESUBMIT 05/04/18
1
1
MATCHLINE: SEE SHEET C125LIMITS OF WORK
EXISTING TREES
DECIDUOUS TREE
ORNAMENTAL TREE
EVERGREEN TREE
DECIDUOUS SHRUBS
EVERGREEN SHRUBS
PERENNIALS / GRASSES
UPLAND SEED MIX
WET/MESIC SEED MIX
WOODLAND SEED MIX
SOD
EXISTING WETLAND BOUNDARY
OPEN WATER
N
Landscape Plan
0'80'40'20'
C127
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
LANDSCAPE NOTES
A.SEE SHEET C125 FOR LANDSCAPE NOTES.
SCALE: 1" = 40'-0"
LANDSCAPE SYMBOLS
SOD, TYP.
BID ALTERNATE #1: RESTORE AREA OF
DEMOLISHED STRUCTURES WITH 12"
TOP SOIL AND UPLAND NATIVE SEED MIX, TYP.
BID ALTERNATE #1: RESTORE AREA OF
DEMOLISHED STRUCTURES WITH 12"
TOP SOIL AND UPLAND NATIVE SEED MIX, TYP.
(1) CO
(1) PO (1) QA
(1) QM
UPLAND NATIVE SEED MIX, TYP.
STORMWATER PERMIT RESUBMIT 05/04/18
1
1
STONE BENCH
VEHICULAR LIGHT POLE
CONCRETE WHEEL STOP
TRASH RECEPTACLE
RECYCLING CONTAINERS
BENCH
DETECTABLE WARNING STRIP
ASPHALT PAVEMENT
HEAVY DUTY CONCRETE PAVEMENT
CONCRETE PAVEMENT
STABILIZED AGGREGATE TRAIL
ENGINEERED WOOD CHIP SURFACING
CONCRETE CURB AND GUTTER
CURB TRANSITION
FLUSH CURB AND GUTTER
CONCRETE BARRIER CURB
SPILLWAY
CONTROL JOINT
ISOLATION (EXPANSION) JOINT
N
Layout and Materials
Enlargement
0'40'20'10'
SCALE: 1" = 20'-0"
C401
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
LAYOUT & MATERIALS NOTES
1. SEE SHEET C110 FOR LAYOUT AND MATERIALS NOTES.
LEGEND
ASPHALT ROADWAY, TYP.
STANDARD CURB & GUTTER, TYP.
SOUTH EDGE OF PARKING LOT ONLY
9.00'
TYP.
1
8
.
0
0
'
2
4
.
0
0
'
2
0
.
0
0
'18.00'
1
0
.
0
0
'
2
5
.
0
0
'
1
8
.
0
0
'
1
0
.
0
0
'27.50'
R1
1
.
5
0
'R19.50'R2.00'16.50'12.00'R2.50'24.74'37.43'
173.00'
19 SPACES
162.00'
30 SPACES
157.00'
10 STANDARD
S
P
A
C
E
S
4 ADA STALLS 99.00'
19 ST
A
N
D
A
R
D
S
T
A
L
L
S
R10.00'R15.00'STONE BOLLARD, TYP.
8
.
0
0
'
TRASH ENCLOSURE
DETECTABLE WARNING, TYP.
FLUSH CURB AND GUTTER, TYP.
HEAVY DUTY CONCRETE PAVING2
C502
4
C502
5
C502
1
C502
ADA PARKING STRIPING9
C502
STABILIZED AGGREGATE TRAIL1
C503
MANUAL RETRACTABLE
BOLLARDS
4
C504
4
C508
SEE ENLARGEMENT
SHEET C402
TRENCH DRAIN, TYP.5
C511
3
C509
20.00'24.00'18.00'CONCRETE BARRIER CURB, TYP.8
C502
10.00'
10.00'
TYP.
STANDARD CURB & GUTTER, TYP.
SOUTH EDGE OF PARKING LOT ONLY
5
C502
ROLL CURB, TYP.
ALL CURBS NOT SHOWN AS FLUSH
OR SOUTH EDGE OF PARKING LOT
6
C502
CURB SPILLWAY, TYP.
LIMESTONE BOULDERS,
TYP. AT ALL TRENCH DRAINS
5
C508
LIMESTONE BOULDERS,
TYP., AT ALL CURB SPILLWAYS
5
C508
BIKE RACK, TYP.
(6) RACKS; 12 PARKING STALLS
BASED ON 2% OF MAX.
BUILDING CAPACITY (554)
9
C503
3.50', TYP.2.00'
STONE BENCH
VEHICULAR LIGHT POLE
CONCRETE WHEEL STOP
TRASH RECEPTACLE
RECYCLING CONTAINERS
BENCH
DETECTABLE WARNING STRIP
ASPHALT PAVEMENT
HEAVY DUTY CONCRETE PAVEMENT
CONCRETE PAVEMENT
STABILIZED AGGREGATE TRAIL
ENGINEERED WOOD CHIP SURFACING
CONCRETE CURB AND GUTTER
CURB TRANSITION
FLUSH CURB AND GUTTER
CONCRETE BARRIER CURB
SPILLWAY
CONTROL JOINT
ISOLATION (EXPANSION) JOINT
N
Layout and Materials
Enlargement
0'20'10'5'
SCALE:
C402
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
LAYOUT & MATERIALS NOTES
1. SEE SHEET C110 FOR LAYOUT AND MATERIALS NOTES.
LEGEND
STABILIZED AGGREGATE TRAIL 1
C503
STONE BENCH, TYP.2
C508
METAL WALKWAY
GRATE, TYP.
DRINKING FOUNTAIN
2
C509
1
C509
PRECAST CONCRETE
BOARDWALK
1
C506 4.00'
4.
0
0
'
8
.
0
0
'
39.46'10.03'
1
2
.
0
0
'
8.
0
0
'4.00'4.
0
0
'44.93'
LIMESTONE BLOCK
STORMWATER
CHAIN ANCHOR, TYP.
6
C508
RIVER ROCK
CHANNEL, TYP.
HEAVY DUTY
CONCRETE
PAVING, TYP.
2
C502
PRECAST CONCRETE
BOARDWALK
1
C506
15.00'
11.12'
R2
0
.
0
0
'
R22.00'
R3.00'R3.00'9.00'
9.00'20.00'
CONCRETE WHEEL STOP, TYP.
10.00'12.22'11.21'5.
5
8
'
21.89'
11.74'
8.
0
0
'
1
1
.
7
3
'
1
2
.
0
0
'
28.18'15.00'
11.78'
21.9
5
'
31.
3
5
'8.00'16.00'14.50'
8.00'8.00'LIMESTONE SEAT, TYP.1
C508
12.00'4.00'
4.
0
0
'
1
0
.
5
3
'
8.
0
0
'
1
0
.
0
8
'
4.
5
0
'
8.
0
0
'
1
6
.
0
1
'37.04'8.00'CLR.DETACTABLE WARNING, TYP.
8.00'
ADA PARKING, TYP.9
C502
MANUAL
RETRACTABLE
BOLLARDS
4
C504
STONE BOLLARD, TYP.4
C5081.57'2.54'LIMESTONE BLOCKS
(SOUTH)
3
C508
CONCRETE BARRIER CURB, TYP.8
C502 8.00'
8.
0
0
'24.00'
2
0
.
0
0
'
ISOLATION JOINT, TYP.
CONTROL JOINT, TYP.
8.
0
0
'
4.
0
0
'
8
.
0
0
'
8.00'
PROVIDE FROST SLAB CONNECTIONS
AT DOORWAYS AS INDICATED ON
ARCHITECTURAL DRAWINGS
4
C503
3
C503
10
C502
STONE BENCH
VEHICULAR LIGHT POLE
CONCRETE WHEEL STOP
TRASH RECEPTACLE
RECYCLING CONTAINERS
BENCH
DETECTABLE WARNING STRIP
ASPHALT PAVEMENT
HEAVY DUTY CONCRETE PAVEMENT
CONCRETE PAVEMENT
STABILIZED AGGREGATE TRAIL
ENGINEERED WOOD CHIP SURFACING
CONCRETE CURB AND GUTTER
CURB TRANSITION
FLUSH CURB AND GUTTER
CONCRETE BARRIER CURB
SPILLWAY
CONTROL JOINT
ISOLATION (EXPANSION) JOINT
N
Layout and Materials
Enlargement
0'40'20'10'
SCALE: 1" = 20'-0"
C403
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
LAYOUT & MATERIALS NOTES
1. SEE SHEET C110 FOR LAYOUT AND MATERIALS NOTES.
LEGEND
1
PLAY EQUIPMENT
7
5
18
CUSTOM PARKOUR: NRO892083
ZIPLINE WITH SLOPE: NRO801
DOUBLE BALANCE BEAM: NRO803
WATER LILIES: NRO820
SIX SIDED CLIMBER: NRO816
TRIPLE SOMERSAULT: NRO809
SPINNER PLATE: NRO110
MULTI SPRINGER: NRO104
OASIS TODDLER WITH FLOWER: NRO552
FLIP WATER MIGRANT WITH 2 SPLASH TABLES: NRO509
SEAT POLES AND ROUND TABLE: NRO212
SNAIL: NRO115
FOREST BUG: NRO113
BEE: NRO113
LOG JAM: NRO892513
2-5 BALANCE NET: NRO893094
SINGLE BALANCE BEAM LOWERED FOR 205: NRO802
2-5 TWISTED NET: NRO893093
1
1. PLAY EQUIPMENT PRODUCTS SUPPLIED BY KOMPAN, INC., ROBINIA
PLAY EQUIPMENT LINE, AND PROVIDED BY THE OWNER ARE LISTED
BELOW. SEE SPECIFICATIONS FOR CONTRACTOR REQUIREMENTS FOR
STORAGE AND INSTALLATION OF EQUIPMENT PROVIDED BY OWNER.
DELIVERY OF MATERIALS IS ANTICIPATED IN SEPTEMBER 2018.
CONTRACTOR TO REVIEW DELIVERY SCHEDULE FOLLOWING NOTICE
TO PROCEED, AND IDENTIFY TO OWNER ANY RECOMMENDED
CHANGES TO THE DELIVERY SCHEDULE. EQUIPMENT MUST BE
DELIVERED TO THE SITE IN 2018.
17
18
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ENGINEERED WOOD CHIP SURFACING
·SEE DETAIL #2 ON THIS SHEET FOR
CRITICAL FALL HEIGHTS
·SEE DETAIL FOR DEPTHS OF
MATERIAL REQUIRED PER FALL
HEIGHT.
8
C503
STABILIZED AGGREGATE TRAIL1
C503
17
16
4
15
13
12
9
14
2
10.00
'
TYP.
21.66'
4.50'
SCALE: 1" = 20'
WOODLAND LAYOUT AND MATERIALS ENLARGEMENT1
HEAVY DUTY CONCRETE PAVING2
C502
SCALE: 1" = 20'
WOODLAND PLAY AREA CRITICAL FALL HEIGHTS2
ZIPLINE AREA
CRITICAL FALL
HEIGHT = 5'-0"
5-12 YEAR OLD PLAY AREA
CRITICAL FALL
HEIGHT = 9'-2"
2-5 YEAR OLD PLAY AREA
CRITICAL FALL
HEIGHT = 6'-0"
PICNIC AREA
NO CRITICAL FALL HEIGHT
UTILIZE MINIMUM DEPTHS OF MATERIALS
STONE BENCH
VEHICULAR LIGHT POLE
CONCRETE WHEEL STOP
TRASH RECEPTACLE
RECYCLING CONTAINERS
BENCH
DETECTABLE WARNING STRIP
ASPHALT PAVEMENT
HEAVY DUTY CONCRETE PAVEMENT
CONCRETE PAVEMENT
STABILIZED AGGREGATE TRAIL
ENGINEERED WOOD CHIP SURFACING
CONCRETE CURB AND GUTTER
CURB TRANSITION
FLUSH CURB AND GUTTER
CONCRETE BARRIER CURB
SPILLWAY
CONTROL JOINT
ISOLATION (EXPANSION) JOINT
N
Layout and Materials
Enlargement
0'40'20'10'
SCALE: 1" = 20'-0"
C404
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
LAYOUT & MATERIALS NOTES
1. SEE SHEET C110 FOR LAYOUT AND MATERIALS NOTES.
LEGEND
CONCRETE PAVEMENT2
C503
SCALE: 1" = 20'
ROUNDABOUT ENLARGEMENT1 3C502
ASPHALT ROADWAY, TYP.
TRASH ENCLOSURE
BENCH, TYP.
DETECTABLE
WARNING, TYP.
HEAVY DUTY CONCRETE PAVING2
C502
1
C502
3
C509
10
.
0
0
'8.71'10.00'24.35'R15.50'R10.00'18.00'
1
0
.
0
0
'
16.00'
1
0
.
0
0
'
PAVEMENT MARKINGS
(WHITE)
22.
0
0
'
ISOLATION JOINT, TYP.
CONNECT TO EXISTING WALK
R48.00'R28.00'
R2.50'R0.30'R0.50'R2.50'R2.50
'
CONNECT TO EXISTING
BOARDWALK ABUTMENT
18.87'
1
0
.
7
4
'25.93'12.
1
1
'10.00
'
8
.
0
0
'
PAVEMENT MARKINGS
(WHITE)
STANDARD CURB & GUTTER, TYP.
SOUTH EDGE OF PARKING LOT ONLY
FLUSH CURB AND GUTTER, TYP.4
C502
5
C502
ROLL CURB, TYP.
ALL CURBS NOT SHOWN AS FLUSH
OR SOUTH EDGE OF PARKING LOT
6
C502
CURB SPILLWAY, TYP.
R50.00'
9.29'
CONTROL JOINT, TYP.
10.00'
3
C503
4
C503
THICKEN ASPHALT TO 8"
TOTAL PAVEMENT
DEPTH FOR 5'-0" FROM
TRASH ENCLOSURE
w
w
PS
D
co
co
co
co
1.0%1.
7
%
1.3%
1.4%
1
.
9%
1.9%
1.
3%
2.
0%
2.0
%
1.
6
%1.6%1.5%1.6%1.5%1.5%1.
2%1.8%1.0%1.7%1.5%
1.7%
1.
9%
1.
4%1.9%900
900
897
897
898
898 899899 901
901 902
903 904905904906907906905
906
905 902903904906905906
906
9059
0
6 906906906 9059049029
0
3
1.
5%1.4%1.0%
905
90
5
E/P 906.03
E/P 905.15
E/P 905.08
E/P 904.62
E/P 904.48
T/C 906.51
T/C 905.81
T/C 905.62
T/C 905.12
T/C 905.06
T/C 905.33
B/S 905.02
T/C 905.17
E/P 906.18
E/P 905.48
E/P 905.29
E/P 904.79
E/P 904.73 E/P 905.01
E/P 904.67
E/P 904.77
B/S 905.12
T/C 905.27
E/P 904.23
B/S 904.58
E/P 904.18
B/S 904.43
E/P 904.05
B/S 904.38
T/C 904.55
E/P 903.54
B/S 903.89
T/C 904.04
B/S 904.19
B/S 904.05
B/S 904.03
B/S 904.15
B/S 904.20
B/S 904.05 B/S 904.05
B/S 904.20
E/P 905.42T/C 905.75
E/P 905.50
E/P 905.72
E/P 905.78
E/P 905.19
E/P 905.20
E/P 905.33
E/P 905.41
T/C 905.83
T/C 906.05
T/C 906.11
T/C 905.52
T/C 905.53
T/C 905.66
T/C 905.74
E/P 905.92T/C 906.25
E/P 905.98T/C 906.31
E/P 905.98T/C 906.31
E/P 905.55
E/P 905.50
T/C 905.88
T/C 905.83
E/P 905.50
E/P 905.56
T/C 905.83
T/C 905.89
E/P 905.93T/C 906.26
E/P 905.72
E/P 905.78
T/C 906.05
T/C 906.11
E/P 905.72T/C 906.05
E/P 905.68T/C 906.01
E/P 905.71T/C 906.04
E/P 905.54T/C 905.87
E/P 905.56T/C 905.89
E/P 905.40
E/P 905.33
E/P 905.25
E/P 905.28
T/C 905.73
T/C 905.66
T/C 905.58
T/C 905.61
E/P 905.69
E/P 905.62
T/C 906.02
T/C 905.95
E/P 905.54T/C 905.87
E/P 905.07
E/P 905.00
T/C 905.57
T/C 905.50
E/P 905.44
T/C 905.94
E/P 905.47T/C 905.97
E/P 905.42
E/P 905.36
T/C 905.92
T/C 905.86
904.92
E/P 904.95
T/C 905.42
T/C 905.45 E/P 904.88 E/P 904.81
E/P 904.78 E/P 904.86
E/P 905.29
E/P 905.35
E/P 905.31
E/P 905.35
T/C 905.30 T/C 905.36
T/C 905.31T/C 905.38
T/C 905.81
T/C 905.85
T/C 905.85
T/C 905.79
E/P 905.15
E/P 905.23T/C 905.56
T/C 905.48
E/P 904.64
E/P 904.75T/C 905.08
T/C 904.97
E/P 904.31T/C 904.64
T/C 905.35
T/C 905.34
T/C 905.34
T/C 905.17
T/C 905.11
T/C 905.11
T/C 905.18
T/C 905.62
T/C 905.59
E/P 905.29
E/P 905.26
E/P 904.85
E/P 904.78
E/P 904.84
E/P 904.78
E/P 905.01
E/P 905.01
E/P 905.02 T/C 904.63E/P 904.30
T/C 905.14
T/C 905.15
E/P 904.81
E/P 904.82
T/C 904.69
T/C 904.79E/P 904.46
E/P 904.36
T/C 904.73
T/C 904.83
T/C 904.87
T/C 905.08
T/C 905.11T/C 905.06
T/C 905.03
T/C 905.00
T/C 905.02
T/C 904.82 T/C 904.77
T/C 904.68
T/C 904.92T/C 904.96
E/P 904.53
E/P 904.56 E/P 904.61
E/P 904.58
E/P 904.33
E/P 904.37
904.52
E/P 904.50
E/P 904.46 E/P 904.42
E/P 904.32 E/P 904.27
T/C 905.85
T/C 906.14
T/C 906.17
T/C 906.33
T/C 906.23
T/C 905.06
T/C 905.14
E/P 905.52
E/P 905.81
E/P 905.84
E/P 906.01
E/P 905.90
E/P 904.81
E/P 904.73
T/C 903.87
T/C 903.90
E/P 903.90
E/P 903.91
E/P 904.17
E/P 904.62
E/P 904.11
E/P 903.90
B/S 905.57
B/S 905.45
B/S 905.34
RIM: 903.89
E/P 904.18
E/P 904.38
E/P 904.58
E/P 904.67
E/P 903.80E/P 903.91
E/P 903.42E/P 903.22
T/C 904.01
T/C 904.02
T/C 904.02
T/C 904.01
E/P 904.19
E/P 904.27
E/P 904.14
E/P 904.53
E/P 904.63
B/S 905.46B/S 905.05
904.47 M.E.±904.00 M.E.±
905.34 M.E.±
905.19 M.E.±904.66 M.E.±
903.23 M.E.±
905.41 M.E.±
903.37 M.E.±
903.79 M.E.±904.33 M.E.±
905.10 M.E.±
905.03 M.E.±
904.09 M.E.±
904.58 M.E.±
E/P 904.89
E/P 904.79
E/P 904.73
E/P 905.35
T/C 905.22T/C 905.12
T/C 905.06
E/P 905.07T/C 905.57
E/P 905.11T/C 905.61
E/P 904.45T/C 904.95
B/S 905.42
B/S 905.46
B/S 904.80
E/P 905.01
T/C 905.68
RIM: 904.66
T/C 906.07
B/S 905.20
E/P 904.52
T/C 904.52
T/C 904.38
T/C 904.54
E/P 904.35T/C 904.68
T/C 904.22
T/C 904.81
T/C 904.95
T/C 905.34
T/C 905.12
T/C 904.44
T/C 904.95
T/C 904.50
T/C 904.51
T/C 905.19
17
.
8
%24.5%19
.
0
%
2
4
.
9%
1
9
.
4
%12.0%
19.5
%18.1%900
900
897897
898
898
899
899
901
901
902
903
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED BACK OF CURB ELEV.
PROPOSED EDGE OF PAVEMENT ELEV.
PROPOSED BACK OF SIDEWALK ELEV.
GRADE BREAK LINE
SLOPE ARROW
LIMITS OF WORK
EMERGENCY OVERFLOW PATH
26.13
25
26
26.13
25
26
1.6%
B/C 26.13
E/P 26.13
B/S 26.13
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
co
w
D
PS
TS
SHEET NOTES
A. SEE SHEET C113 FOR GRADING NOTES
N
Grading Enlargements
0'40'20'10'
SCALE: 1"=20'
C405
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SEE GRADING ENLARGEMENT
SHEET C406
GRADING SYMBOLS
FFE=907.00
TRENCH DRAIN, 10 LF 5
C511
TRENCH DRAIN, 10 LF 5
C511
TRENCH DRAIN, 10 LF5
C511
TRENCH DRAIN, 10 LF5
C511
TRENCH DRAIN, 10 LF5
C511
UTILITY SYMBOLS
PS
co
co
co
co
905.40
905.20
905.64
905.48
906.00
906.16
905.88
1.3%1.4%1.6%1.2%
1.4%1.9%1.2%0.9%1.
0
%2.0%2.0%2.
4%
1.3
%
T/C 906.36
B/S 906.48
B/S 906.65
T/C 906.34
E/P 906.16T/C 906.20
906.78
907.00
906.58
906.65
T/C 906.05
E/P 906.01
E/P 905.92
E/P 905.97
E/P 906.14
E/P 906.34
E/P 906.37
906.67
906.46
906.95
907.00
906.60
906.70
906.84
906.82
906.70
906.95
907.00
907.00
907.00
907.00
907.00
907.00
907.00
907.00
906.82
906.60
906.67
906.80
907.04
907.06
907.14
907.10
907.22
907.15
906.90
907.00
906.82
906.90
906.90
906.90
907.01
906.30
906.50
906.53
B/S 906.32B/S 906.40
906.21
906.22
906.26
906.22
906.90
906.85
906.85
906.85
906.85
B/S 906.69
906.73
906.90
906.80
B/S 906.55
906.88
907.00
906.90
906.88
906.84
B/S 906.63
B/S 906.61
906.68
906.82
906.98
906.88
906.88
906.90
906.83
906.75
906.83
906.84
906.68
906.66
907.00
907.00
906.76
B/S 906.57
906.85
906.95
B/S 906.47
B/S 906.56
906.71
B/S 906.83
906.75
906.72
906.76
906.70
906.78
906.80
907.00
907.00
906.88
906.88
906.67
1.5%1.9%
1.9
%2.0%1.
7%
1.
0%
1.9
%
2.0%1.2%1.1%1.1%907.00
907.00
907.00
907.00
907.00
906 9061.8
%
T/C 907.32
T/C 907.20
T/C 907.20
T/C 907.32
907.00
T/C 907.40
T/C 907.40
T/C 907.40
T/C 907.50
T/C 907.40
T/C 907.50
T/C 907.45
T/C 907.28
T/C 907.50
905906
906
T.W. 908.25
T.S. 908.00
T.S. 908.50
T.S. 908.00
T.S. 909.50
T.S. 907.50
T.W. 908.25
T.W. 908.25
T.W. 908.251.8%T.W. 908.25
T.W. 908.50
T.W. 908.25
9
0
6
906
906
1.
4
%
RIM: 905.50
RIM: 905.65
906.80
906.86
906.82
1
.
4%1.0%1.6%T/C 906.68
T/C 906.39
T/C 905.96
T/C 906.01
T/C 906.18
T/C 906.38
T/C 906.41
E/P 906.35
E/P 906.30
E/P 906.32
E/P 906.64
T/C 906.28E/P 906.24
T.S. 907.80
T.S. 907.90
T.S. 907.50
T.S. 907.30
E/P 906.03
T/C 906.07
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED BACK OF CURB ELEV.
PROPOSED EDGE OF PAVEMENT ELEV.
PROPOSED BACK OF SIDEWALK ELEV.
GRADE BREAK LINE
SLOPE ARROW
LIMITS OF WORK
EMERGENCY OVERFLOW PATH
26.13
25
26
26.13
25
26
1.6%
B/C 26.13
E/P 26.13
B/S 26.13
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
co
w
D
PS
TS
SHEET NOTESN
Grading Enlargements
0'20'10'5'
SCALE: 1"=10'
C406
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
A. SEE SHEET C113 FOR GRADING NOTES
GRADING SYMBOLS
FFE=907.00
PROPOSED VEGETATED
FILTER STRIP WITH INFILTRATION
TRENCH
7
L502
UTILITY SYMBOLS
BUILDING DOWNSPOUT
LOCATION
BUILDING DOWNSPOUT
LOCATION
BUILDING DOWNSPOUT
LOCATION
BUILDING DOWNSPOUT
LOCATION
BUILDING DOWNSPOUT
LOCATION
wco
13
+
0
0
14+00
15+00
16+0
017+00P
R
C
:
1
3
+
1
4
.
0
7
PT: 14+90.58
PI: 15+35.40
PI: 16+9
8.671.6%1.5%1.5%1.5
%
1.5%1.5%1.5%1.5%
1.6%1.5%1.5%1.
2%1.8%1.0%1.7%1.5%
1.7%
1.2%1.5%1.
9%1.9%1.
9
%2.6%1.5%900905901902903904904905902
903904906907 9008999019029029029039049059069029
0
3
E/P 904.62
E/P 904.48
B/S 904.38
E/P 903.54
B/S 903.89
T/C 904.04
B/S 904.20
B/S 904.05 B/S 904.05
B/S 904.20
E/P 904.64
T/C 904.97
E/P 904.31T/C 904.64
T/C 904.63E/P 904.30
T/C 904.69E/P 904.36
T/C 903.87
T/C 903.90
E/P 903.90
E/P 903.91
E/P 904.62
E/P 904.11
E/P 903.90
B/S 905.57
B/S 905.45
B/S 905.34
E/P 904.42
E/P 904.36
RIM: 903.89
E/P 904.18
E/P 904.38
E/P 904.58
E/P 904.67
E/P 904.67
E/P 904.67
E/P 904.67
E/P 904.67E/P 903.80E/P 903.91
E/P 903.42E/P 903.22
E/P 903.39
903.52 E/P 903.39
E/P 902.84
902.93
E/P 902.84
E/P 904.67
E/P 905.05
E/P 905.05
E/P 905.05
E/P 905.05
E/P 905.05
E/P 905.05
E/P 905.05
E/P 905.05T/C 905.37
T/C 905.38
T/C 905.37
T/C 905.38
T/C 905.37
T/C 905.38
T/C 905.38
T/C 905.38
T/C 904.01 T/C 904.01
T/C 904.01T/C 904.01
T/C 904.02
T/C 904.02
T/C 904.02
T/C 904.01
T/C 904.01
E/P 904.19
E/P 904.27
E/P 904.14
E/P 904.53
E/P 904.39
E/P 904.63
E/P 904.49
E/P 904.79
E/P 904.65
E/P 904.89
904.44
E/P 903.09
E/P 903.19
E/P 903.48
E/P 904.01
E/P 904.30
E/P 903.98E/P 904.05
E/P 903.93T/C 903.99
E/P 904.67
E/P 904.67T/C 904.10
T/C 904.04E/P 904.82 T/C 904.04E/P 904.47T/C 904.05
T/C 904.04T/C 904.06
T/C 904.05
E/P 904.78
E/P 904.54
E/P 904.70
T/C 904.36
T/C 904.26
B/S 904.62
B/S 905.46
B/S 904.74
B/S 905.01
B/S 905.32B/S 905.47
B/S 904.58
B/S 903.08
B/S 902.93
900.94 M.E.±
B/S 904.86
B/S 904.44
B/S 904.00
B/S 904.15
B/S 901.90
B/S 902.05
B/S 902.73
B/S 902.88
B/S 901.56
B/S 901.71
B/S 901.16
B/S 901.01
B/S 900.96
B/S 900.88
B/S 900.94
B/S 901.90
B/S 901.75
B/S 905.05
B/S 901.09
900.62 M.E.±
906.95
E/P 905.01
E/P 904.26
E/P 904.23T/C 904.56
RIM: 901.63
RIM: 901.11
E/P 904.38
E/P 904.52
T/C 904.52
T/C 904.38
T/C 904.54
E/P 904.35T/C 904.68
T/C 904.22
T/C 904.81
T/C 904.95
T/C 905.34
T/C 904.44
T/C 904.95
T/C 904.51
1
7
.
8
%
902.50
9029039029021
9
.
4
%12.0%
19.5
%
EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED BACK OF CURB ELEV.
PROPOSED EDGE OF PAVEMENT ELEV.
PROPOSED BACK OF SIDEWALK ELEV.
GRADE BREAK LINE
SLOPE ARROW
LIMITS OF WORK
EMERGENCY OVERFLOW PATH
26.13
25
26
26.13
25
26
1.6%
B/C 26.13
E/P 26.13
B/S 26.13
co
1.
6
%
907.00
907.00
906.67
907.04
907.06
907.14
907.10
907.22
907.15
906.90
907.00
906.82
906.90
907.01
906.30
906.50
906.53
B/S 906.32B/S 906.40
906.21906.22
906.26 906.221.2%1.1%1.1%905 903904906T/C 907.40
T/C 907.40
906
RIM: 905.50
906.80
906.86
906.82
1
.
4%1.0%T.S. 907.80
T.S. 907.90
T.S. 907.50
T.S. 907.30
E/P 905.08
904.47 M.E.±904.00 M.E.±
902.58 M.E.±
903.13 M.E.±903.50 M.E.±
903.54 M.E.±
903.22 M.E.±
904.22 M.E.±
904.14 M.E.±
904.79 M.E.±
905.55 M.E.±
905.73 M.E.±
905.34 M.E.±
905.19 M.E.±904.66 M.E.±
903.23 M.E.±
905.41 M.E.±
905.69 M.E.±
905.39 M.E.±
904.70 M.E.±
904.13 M.E.±
904.06 M.E.±
903.30 M.E.±
903.29 M.E.±
903.64 M.E.±903.32 M.E.±
902.83 M.E.±
903.37 M.E.±
903.79 M.E.±904.33 M.E.±
904.84 M.E.±
904.00 M.E.±
902.80 M.E.±
903.92 M.E.±
904.40 M.E.±
905.10 M.E.±
905.03 M.E.±
904.09 M.E.±
904.02 M.E.±
903.59 M.E.±
903.08 M.E.±
903.37 M.E.±
903.73 M.E.±
903.60 M.E.±
904.00 M.E.±
904.08 M.E.±
904.11 M.E.±
904.61 M.E.±
904.58 M.E.±
B/S 905.20
T/C 905.12
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
co
w
D
PS
TS
SHEET NOTESN
Grading Enlargements
0'40'20'10'
SCALE: 1"=20'
C407
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
A. SEE SHEET C113 FOR GRADING NOTES
GRADING SYMBOLS
SCALE: 1" = 20'
ROUNDABOUT GRADING ENLARGEMENT1 SCALE: 1" = 20'
WOODLAND GRADING ENLARGEMENT2
UTILITY SYMBOLS
wD
D
10+00
11+00
12+00
13
+
0
0
14+00
BP: 10+00.00
PC: 10+51.93
PT: 11+42.40
PC: 11+90.51
P
R
C
:
1
3
+
1
4
.
0
7
2
.
7%4.7%1.5%1.5
%2.6%1.5%
4.4%
900
905
899
901
902
903
904
901902
903
8
9
5
9
0
0
8
9
3894
89
6
896 897898
89
9
9
0
1
900897898899901 896 897898898899899905902
903904906
895
895
900
892
893
894
896
897
898
899
901
901 89589590089289289389389489689789889989589590089
2
8
9
3
8
94
896897898899898
899
898 899900901900
899
5.2%
25.0%
E/P 903.39
903.52 E/P 903.39
E/P 902.84
902.93
E/P 902.84
E/P 902.34 902.47
E/P 902.34
E/P 902.24902.37 E/P 902.24
E/P 902.14
902.27 E/P 902.14
E/P 902.16
E/P 901.99902.12
E/P 901.99
E/P 901.82
902.06 E/P 901.93
E/P 900.10 900.22 E/P 900.07
E/P 899.70
E/P 901.44
E/P 899.40
E/P 899.05 898.62
E/P 898.42 E/P 898.42
E/P 898.27E/P 899.37
E/P 901.96
E/P 901.36
E/P 903.09
E/P 903.19
B/S 901.56
B/S 901.71
B/S 901.16
B/S 901.01
B/S 900.96
B/S 900.88
B/S 900.94
900.65 M.E.±
B/S 901.90
B/S 901.75
B/S 902.00B/S 901.85
B/S 902.38
B/S 902.20
B/S 901.30
B/S 901.20
899.40
901.46
902.08E/P 901.90 E/P 901.95
B/S 901.09
900.62 M.E.±
RIM: 901.11
899.30 M.E.±
899.30 M.E.±
33.0
%
14.
8
%902902RIM: 903.40
RIM: 900.9424.5%4.9%18.1%900
898
899
901
25.0%33.3%33.3%25.0%25.0%
25
.
0
%
3.
3%1.6%4.6%4.7%EXISTING MAJOR CONTOUR
EXISTING MINOR CONTOUR
PROPOSED MAJOR CONTOUR
PROPOSED MINOR CONTOUR
EXISTING SPOT ELEVATION
PROPOSED SPOT ELEVATION
PROPOSED BACK OF CURB ELEV.
PROPOSED EDGE OF PAVEMENT ELEV.
PROPOSED BACK OF SIDEWALK ELEV.
GRADE BREAK LINE
SLOPE ARROW
LIMITS OF WORK
EMERGENCY OVERFLOW PATH
26.13
25
26
26.13
25
26
1.6%
B/C 26.13
E/P 26.13
B/S 26.13
GATE VALVE BOX
FIRE HYDRANT ASSEMBLY
TAPPING SLEEVE
CLEANOUT
GRINDER PUMP STATION
STORM STRUCTURE
INLET
YARD DRAIN
FLARED END SECTION
WATER MAIN
DIRECTIONAL BORING
SANITARY SEWER
FORCE MAIN
STORM SEWER
UNDERDRAIN
NATURAL GAS LINE
COMPRESSED AIR LINE
WET POND
AERATION COMPRESSOR CABINET
AERATION REMOTE MANIFOLD
AERATION MEMBRANE DIFFUSOR
co
w
D
PS
TS
SHEET NOTESN
Grading Enlargements
0'40'20'10'
SCALE: 1"=20'
C408
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
A. SEE SHEET C113 FOR GRADING NOTES
GRADING SYMBOLS
EMERGENCY BROAD-CRESTED OVERFLOW WEIR
ELEV: 903.10
EMERGENCY BROAD-CRESTED OVERFLOW WEIR
ELEV: 899.40
BROAD-CRESTED CONVEYANCE WEIR
ELEV: 897.60
BROAD-CRESTED OVERFLOW WEIR
ELEV: 900.10
POND TYPICAL H.W.E.: 897.50±
POND TYPICAL H.W.E.: 897.00±
POND TYPICAL H.W.E.: 897.00±
UTILITY SYMBOLS
CONVEYANCE WEIR REINFORCEMENT 8
C508
LIMITS OF WORK
EXISTING TREES
DECIDUOUS TREE
ORNAMENTAL TREE
EVERGREEN TREE
DECIDUOUS SHRUBS
EVERGREEN SHRUBS
PERENNIALS / GRASSES
UPLAND SEED MIX
WET/MESIC SEED MIX
WOODLAND SEED MIX
SOD
EXISTING WETLAND BOUNDARY
OPEN WATER
N
Landscape Enlargements
0'40'20'10'
SCALE: 1" = 20'-0"
C409
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
LANDSCAPE NOTES
A.SEE SHEET C125 FOR LANDSCAPE NOTES.
B.SEE SHEET C125 FOR PROPOSED TREE CALLOUTS
LANDSCAPE SYMBOLS
EXISTING WOODLAND DRIPLINE
SOD, TYP.
UPLAND SEED
MIX, TYP.
(49) PVS
(133) EP
(71) SH
(5) RAG (38) SH
INTERPLANT
(91) LSP
WITH (35) ASB
(123) EP
(70) SH
(71) SH
(5) RAG
(82) SH
INTERPLANT
(105) LSP
WITH (42) ASB
(48) SH
(8) RAG
(50) SH
(10) HK
(45) PVH
(1) CO
(1) QB
(1) PO
(1) QB
(1) PO
(1) AG
(1) PO
(1) CO
(1) PO
(1) PO
(1) QB
(1) QB
(1) GD
(1) QR
(1) CK
(1) PA
(1) PA
(45) SH
(264) DM
(1) GD
(2) QB
(3) CO
(1) GD
(1) QB
(1) TD
(1) COV
(1) AG
(1) TD
(1) QB
(1) CO
(1) PO
(1) AG
WOODLAND SEED MIX, TYP.
SEE SHEET C410 FOR LANDSCAPE ENLARGEMENT
(1) QB
(1) QB
(2) PO
(1) GD
WET/MESIC SEED
MIX, TYP.
STORMWATER PERMIT RESUBMIT 05/04/18
1
1
NATIVE SEEDING LIMITS SIGN, TYP.
INSTALL AT 150' O.C. MAXIMUM AROUND
PERIMETER OF PEDESTRIAN AREAS
WHERE ADJACENT TO NATIVE SEEDING,
AS SHOWN.
8
C514
LIMITS OF WORK
EXISTING TREES
DECIDUOUS TREE
ORNAMENTAL TREE
EVERGREEN TREE
DECIDUOUS SHRUBS
EVERGREEN SHRUBS
PERENNIALS / GRASSES
UPLAND SEED MIX
WET/MESIC SEED MIX
WOODLAND SEED MIX
SOD
EXISTING WETLAND BOUNDARY
OPEN WATER
N
Landscape Enlargements
0'20'10'5'
SCALE: 1" = 10'-0"
C410
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
LANDSCAPE NOTES
A.SEE SHEET C125 FOR LANDSCAPE NOTES.
LANDSCAPE SYMBOLS
(13) AST
(26) AQC
(8) AQC
(18) EH(22) OR
(39) OR
(1) CK
(3) AM
(20) AST
(30) EH (15) TO
(38) OR
(3) AM
(21) PR
(20) AQC
(26) MF
(27) TO
(114) PQ
(52) PR
(1) CF
(1) CK
(4) AM
(37) PR
(12) EH
(19) TO
(15) PQ
(23) AST
(12) AQC
(18) AQC
(1) AGA
(2) AM
(4) AST
(7) PVS
(5) PVS
(5) PVS
(6) PVS
(7) PVS
(10) SSC
(5) COS
(4) COS
(4) COS
(8) AST
(18) MF
(41) PR
(26) EH
(16) PR
(10) EH
(71) PQ
(19) EH
(17) AST
(10) MF
(2) MF
(6) SSC
(23) EP
(26) AMP
(10) ASB
(83) DM
(18) TO
(22) LC
(13) CHO
(22) EP
(8) SH
(32) LSP
(9) SH
(22) AMP
(15) EP
(15) RS
(1) PS
(1) PS
(1) TD
(3) BNL
(2) BNL
(4) EPU
(4) COC
(12) PVS
(2) CAM
(3) SG
(27) LC
(7) BA
(3) SG
(12) VN
(1) COC
(7) FR
(1) COC
(21) SR
(29) PD
(4) SG
(3) COC
(36) SR(6) EPU
(16) PVS
(27) RF
(2) SG
(11) PD
(2) VN
(11) IVR
(7) CHO
(19) BA
(6) BA
(6) FR
(24) SS
(3) CAM
(8) VN
(22) PD
(80) ST
(7) EPU
(4) PVS
(4) SG
(20) CPA
(30) CS
(6) JE
(10) IVE
(28) PVS
(25) FR
(10) IVE
(16) SH
(102) LSP
(58) SH
(82) LSP
(18) SH
(10) SH
(24) SH
(5) CAM
(9) FR (5) SG
(11) PVS
(9) EPU
(25) CS
(1) BN
(1) QB
(1) TD
(1) PO
(1) QM
(1) QB
(23) PVH
(36) BB
(1) NS
WOODLAND SEED MIX, TYP.
(3) CAM
(9) PVS
(12) PD
STORMWATER PERMIT RESUBMIT 05/04/18
1
1
NATIVE SEEDING LIMITS SIGN, TYP.
INSTALL AT 150' O.C. MAXIMUM AROUND
PERIMETER OF PEDESTRIAN AREAS
WHERE ADJACENT TO NATIVE SEEDING,
AS SHOWN.
8
C514
LIMITS OF WORK
EXISTING TREES
DECIDUOUS TREE
ORNAMENTAL TREE
EVERGREEN TREE
DECIDUOUS SHRUBS
EVERGREEN SHRUBS
PERENNIALS / GRASSES
UPLAND SEED MIX
WET/MESIC SEED MIX
WOODLAND SEED MIX
SOD
EXISTING WETLAND BOUNDARY
OPEN WATER
N
Landscape Enlargements
C411
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
LANDSCAPE NOTES
A.SEE SHEET C125 FOR LANDSCAPE NOTES.
LANDSCAPE SYMBOLS
(47) SH
(16) PVS
(1) LT (13) COS
INTERPLANT
(47) RS WITH (47) EP
SCALE: 1" = 10'
ROUNDABOUT LANDSCAPE ENLARGEMENT1
SCALE: 1" = 20'
STORMWATER BASIN ENLARGEMENT2
(1) CO
(1) TD
(1) COV
(20) COS
(1) TD
(1) TD
(16) COS
(3) BNL
(1) PO
UPLAND SEED MIX, TYP.
6
C508 LIMESTONE BOULDERS, TYP.
WET/MESIC SEED MIX, TYP.
0'20'10'5'
STORMWATER PERMIT RESUBMIT 05/04/18
1
1
Stormwater Pollution Prevention
Notes
0'40'20'10'
SCALE:
C500
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
STORMWATER POLLUTION
PREVENTION CHECKLIST A
A1:PLAN INDEX: SEE COVER SHEET
A2:11"X17" EXHIBIT DENOTING BOUNDARIES AND STREETS AS
APPLICABLE IS PROVIDED SEPARATELY.
A3:PROJECT NARRATIVE DESCRIBING NATURE AND PURPOSE OF THE
PROJECT: BUILDING OF THE WEST PARK GROVES PAVILION
BUILDING AND ASSOCIATED SITE WORK INCLUDING, BUT NOT
LIMITED TO, PARKING AND ROADWAY, PEDESTRIAN PLAZAS,
GRADING, SITE UTILITIES, LANDSCAPING, SITE LIGHTING, WOODLAND
TRAIL AND PLAY AREA, DIRECTLY WEST OF THE EXISTING WEST
PARK IN CARMEL, INDIANA.
A4:VICINITY MAP: DENOTED ON COVER SHEET OF DRAWING SET
A5:LEGAL DESCRIPTION OF PROPERTY: SEE EXISTING CONDITIONS
SHEETS V001 - V004.
A6:LOCATION OF ALL PROPOSED SITE ELEMENTS: SEE SHEET C109 -
C110.
A7:14 DIGIT HYDROLOGIC UNIT CODE: 05120201090060
A8:STATE OR FEDERAL WATER QUALITY PERMITS:
-401 WQC FROM IDEM
-404 PERMIT FROM U.S. ARMY CORPS OF ENGINEERS
A9:SPECIFIC POINTS WHERE STORMWATER DISCHARGE WILL LEAVE
THE SITE: 6.1 ACRES IF THE TOTAL PROPOSED 8.4 ACRES OF
DISTURBANCE WILL LEAVE THE SITE TO THE EAST THROUGH THE
PROPOSED DETENTION SYSTEM. THE REMAINDER OF THE
DEVELOPMENT WILL LEAVE THE SITE THROUGH SHEET DRAINAGE.
SEE GRADING AND UTILITY DRAWING SHEETS.
A10:LOCATION OF ALL WETLANDS, LAKES & WATER COURSES ON AND
ADJACENT TO SITE: SEE SHEETS V001 - V004.
A11:RECEIVING WATERS: WILLIAMS CREEK
A12:IDENTIFICATION OF POTENTIAL DISCHARGES TO GROUNDWATER:
NONE.
A13:100-YEAR FLOODPLAINS, FLOODWAYS AND FLOOD FRINGES: THE
PROJECT SITE IS LOCATED OUTSIDE ANY MAPPED FLOODPLAINS,
FLOODWAYS AND FLOOD FRINGES.
A14:PRE-CONSTRUCTION & POST-CONSTRUCTION PEAK DISCHARGE:
10YR PRE-CONSTRUCTION PEAK DISCHARGE = 28.6 cfs
10YR POST CONSTRUCTION PEAK DISCHARGE = 25.9 cfs
A15:ADJACENT LAND USE
NORTH: RESIDENTIAL
SOUTH: SCHOOL
EAST: PARKS AND RECREATION
WEST: RESIDENTIAL
A16:LOCATIONS AND APPROXIMATE BOUNDARIES OF ALL DISTURBED
AREAS: SEE SITE PREPARATION SHEETS C105-C108.
A17:IDENTIFICATION OF EXISTING VEGETATIVE COVER: SEE SHEETS
V001-V004.
A18:SOILS MAP INCLUDING DESCRIPTION AND LIMITATIONS: THIS SHEET.
A19:LOCATIONS, SIZE AND DIMENSIONS OF PROPOSED STORMWATER
SYSTEMS: SEE SHEET C117.
A20:LOCATIONS, SIZE AND DIMENSIONS OF ANY PROPOSED OFF-SITE
CONSTRUCTION ACTIVITIES ASSOCIATED WITH THIS PROJECT: NONE
A21:LOCATIONS OF SOIL STOCKPILES: NONE
A22:EXISTING TOPOGRAPHY: SEE SHEETS V001 - V004.
A23:PROPOSED FINAL TOPOGRAPHY: SEE SHEETS C113 - C115.
STORMWATER POLLUTION
PREVENTION CHECKLIST B
B1:DESCRIPTION OF POTENTIAL POLLUTANTS SOURCES ASSOCIATED
WITH THE CONSTRUCTION ACTIVITIES: SILT AND SEDIMENT FROM
EXPOSED SOILS, LEAVES, MULCH, VEHICULAR SOURCES SUCH AS
LEAKING FUEL OR OIL, BRAKE FLUID, BRAKE DUST, TRASH, DEBRIS,
BIOLOGICAL AGENTS FOUND IN TRASH, FERTILIZERS, HERBICIDES,
PESTICIDES, ACID RAIN, LIME DUST AND CONCRETE WASHOUT.
B2:SEQUENCING OF STORMWATER QUALITY IMPLEMENTATION
RELATIVE TO LAND DISTURBANCE ACTIVITIES:
THIS PLAN HAS BEEN CREATED IN AN EFFORT TO ELIMINATE
SEDIMENT FROM LEAVING THE PROJECT SITE DURING
CONSTRUCTION PROTECTING THE ADJOINING PROPERTIES AND THE
WILLIAMS CREEK WATERSHED. A MAJORITY OF THE 40 ACRE SITE
DRAINS TO THE SOUTHEAST TO AN EXISTING CULVERT ON 116TH,
THEN ONTO A REGULATED DRAIN. WILLIAMS CREEK IS THE
RECEIVING WATER BODY FOR THE SITE.
B3:STABLE CONSTRUCTION ENTRANCE LOCATION(S) AND
SPECIFICATIONS. SEE PLAN SHEETS C101 AND C103 FOR LOCATIONS
AND EROSION CONTROL DETAILS SHEET C501 FOR CONSTRUCTION
ENTRANCE DETAILS AND SPECIFICATIONS. ADDITIONAL TEXT AND
INSTRUCTIONS CAN BE FOUND ON THIS SHEET.
B4:SEDIMENT CONTROL MEASURES FOR SHEET FLOW AREAS: SILT
FENCING. SEE PLAN SHEETS C101 - C104 FOR LOCATIONS OF
SEDIMENT CONTROL MEASURES AND SHEET C501 FOR
CONSTRUCTION DETAILS AND SPECIFICATIONS. ADDITIONAL
INFORMATION CAN BE FOUND ON THIS SHEET.
B5:SEDIMENT CONTROL MEASURES FOR CONCENTRATED FLOW AREAS:
NONE ANTICIPATED.
B6:STORM SEWER INLET PROTECTION MEASURE, LOCATIONS AND
SPECIFICATIONS. SEE SHEET C101 FOR CULVERT PROTECTION
LOCATION AND SHEET C501 FOR CONSTRUCTION DETAILS AND
SPECIFICATIONS.
B7:RUNOFF CONTROL MEASURES: NOT APPLICABLE
B8:STORMWATER OUTLET PROTECTION MEASURES: NOT APPLICABLE
B9:GRADE STABILIZATION STRUCTURE LOCATIONS AND
SPECIFICATIONS: NOT APPLICABLE.
B10:LOCATION, DIMENSION, SPECIFICATIONS AND CONSTRUCTION
DETAILS FOR EACH STORMWATER QUALITY MEASURE: SEE PLAN
SHEETS C101 - C104 AND SHEET C501 FOR CONSTRUCTION DETAILS
AND SPECIFICATIONS.
B11:TEMPORARY SURFACE STABILIZATION METHODS APPROPRIATE FOR
EACH SEASON: SEE SHEET C501.
B12:PERMANENT SURFACE STABILIZATION SPECIFICATIONS: SEE PLAN
SHEETS C101 - C104 FOR LOCATIONS OF PERMANENT SURFACE
STABILIZATION MEASURES AND SHEET C501 FOR CONSTRUCTION
DETAILS AND SPECIFICATIONS.
B13:MATERIAL HANDLING AND SPILL PREVENTION PLAN:
PURPOSE:
THE INTENTION OF THIS SPILL PREVENTION, CONTROL AN
COUNTERMEASURES (SPCC) IS TO ESTABLISH THE PROCEDURES
AND EQUIPMENT REQUIRED TO PREVENT THE DISCHARGE OF OIL
AND HAZARDOUS SUBSTANCES IN QUANTITIES THAT VIOLATE
APPLICABLE WATER QUALITY STANDARDS, CAUSE A SHEEN UPON
OR DISCOLORATION OF THE SURFACE OF NAVIGABLE WATERS
ADJOINING SHORELINE, OR CAUSE SLUDGE OR EMULSION TO BE
DEPOSITED BENEATH THE SURFACE OF THE WATER OR ADJACENT
SHORELINES. THE PLAN ALSO ESTABLISHES THE ACTIVITIES
REQUIRED TO MITIGATE SUCH DISCHARGES (I.E.,
COUNTERMEASURES) SHOULD THEY OCCUR.
DEFINITIONS:
POLLUTANT: MEANS POLLUTANT OF ANY KIND OR IN ANY FORM,
INCLUDING BUT NOT LIMITED TO SEDIMENT, PAINT, CLEANING
AGENTS, CONCRETE WASHOUT, PESTICIDES, NUTRIENTS, TRASH,
HYDRAULIC FLUIDS, FUEL, OIL, PETROLEUM, FUEL OIL, SLUDGE, OIL
REFUSE, AND OIL MIXED WITH WASTES OTHER THAN DREDGED SOIL.
DISCHARGE: INCLUDES BUT IS NOT LIMITED TO, ANY SPILLING,
LEAKING, PUMPING, POURING, EMITTING, EMPTYING, OR DUMPING.
NAVIGABLE WATERS: MEANS ALL WATERS OF THE UNITED STATES
THAT ARE CONNECTED WITH A NAVIGABLE STREAM, LAKE OR SEA.
[NOTE: THIS DEFINITION IS USUALLY INTERPRETED TO MEAN ANY
STORMWATER (EVEN NORMAL DRY WASH OR STORM SEWER) THAT
EVENTUALLY DRAINS INTO A NAVIGABLE STREAM].
PLAN REVIEW AMENDMENTS:
THIS PLAN SHALL BE REVIEWED AND/OR AMENDED, IF NECESSARY,
WHENEVER THERE IS A CHANGE IN THE DESIGN OF THE SITE,
CONSTRUCTION, OPERATION OR MAINTENANCE WHICH MATERIALLY
AFFECTS THE SITE'S POTENTIAL FOR THE DISCHARGE OF
REGULATED MATERIALS.
PREDICTION OF POTENTIAL SPILLS:
1.NEAREST NAVIGABLE WATER: WILLIAMS CREEK
2.DRAINAGE SYSTEM: THE SITE WILL DRAIN SOUTHEAST TO THE
EXISTING CULVERT ON 116TH STREET, WHICH FLOWS TO A
REGULATED DRAIN. THE REGULATED DRAIN FLOWS TO WILLIAMS
CREEK.
3.POSSIBLE SPILL SOURCES: VEHICULAR SOURCES SUCH AS LEAKING
FUEL OR OIL, BRAKE FLUID, GREASE, ANTIFREEZE, CONSTRUCTION
TRASH, DEBRIS, BIOLOGICAL AGENTS FOUND IN TRASH AND DEBRIS,
AND FERTILIZERS.
4.GROUNDWATER CONTAMINATION: THERE WILL BE NO ABOVE
GROUND OR UNDER GROUND STORAGE TANK OR FACILITIES AT THE
SITE. THE FACILITY WILL UTILIZE DOMESTIC WATER AND SANITARY
SEWER.
ALERT PROCEDURES FOR SPILLS:
1.ANY PERSONNEL OBSERVING A SPILL WILL IMMEDIATELY INITIATE
THE FOLLOWING PROCEDURE:
1.1.DIALING "0" FROM ANY PHONE.
1.2.NOTIFY THE APPROPRIATE EMERGENCY PERSONNEL.
2.THE EMERGENCY COORDINATOR WILL THEN TAKE THE FOLLOWING
ACTIONS:
2.1.BARRICADE THE AREA ALLOWING NO VEHICLES TO ENTER OR
LEAVE THE SPILL ZONE.
2.2.NOTIFY THE INDIANA DEPARTMENT OF ENVIRONMENTAL
MANAGEMENT (IDEM), OFFICE OF EMERGENCY RESPONSE BY
CALLING THE TELEPHONE NUMBER:
OFFICE:317-233-7745
TOLL-FREE:800-233-7745
ALSO CALL THE NATIONAL RESPONSE CENTER AT 800-424-8802 AND
PROVIDE THE FOLLOWING INFORMATION:
·TIME OF OBSERVATION OF THE SPILL
·LOCATION OF THE SPILL
·IDENTITY OF THE MATERIAL SPILLED
·PROBABLE TIME OF THE SPILL
·VOLUME OF THE SPILL AND DURATION
·PRESENT AND ANTICIPATED MOVEMENT OF THE SPILL
·WEATHER CONDITIONS
·PERSONNEL AT THE SCENE
·ACTION INITIATED BY PERSONNEL
2.1.NOTIFY THE FIRE DEPARTMENT: 911
2.2.NOTIFY THE POLICE DEPARTMENT: 911
2.3.NOTIFY WASTER RECOVERY CONTRACTOR, MAINTENANCE
PERSONNEL OR OTHER CONTRACTUAL PERSONNEL AS
NECESSARY FOR CLEANUP.
2.4.COORDINATE AND MONITOR CLEANUP UNTIL THE SITUATION
HAS BEEN STABILIZED AND ALL SPILLS HAVE BEEN ELIMINATED.
2.5.COOPERATE WITH THE IDEM-OER ON PROCEDURES AND
REPORTS INVOLVED WITH THE EVENT.
CLEANUP PARAMETERS:
1.THE DEVELOPER/CONTACTOR SHALL BE CONTINUALLY KEPT
INFORMED AND MAINTAIN LISTS OF QUALIFIED CONTRACTORS AND
AVAILABLE VAC-TRCUKS, TANK PUMPERS AND OTHER EQUIPMENT
READILY ACCESSIBLE FOR CLEANUP OPERATIONS. IN ADDITION, A
CONTINUALLY UPDATED LIST OF AVAILABLE ABSORBENT MATERIALS
AND CLEANUP SUPPLIES SHOULD BE KEPT ON SITE.
2.ALL MAINTENANCE PERSONNEL WILL BE MADE AWARE OF
TECHNIQUES FOR PREVENTIONS OF SPILLS. THEY WILL BE
INFORMED OF THE REQUIREMENTS AND PROCEDURES OUTLINED IN
THIS PLAN. THEY WILL BE KEPT ABREAST OF CURRENT
DEVELOPMENTS OR NEW INFORMATION ON THE PREVENTION OF
SPILLS AND/OR NECESSARY ALTERATIONS TO THIS PLAN.
3.WHEN SPILLS OCCUR WHICH COULD ENDANGER HUMAN LIFE AND
THIS BECOMES PRIMARY CONCERN, THE DISCHARGE OF THE LIFE
SAVING PROTECTION FUNCTION WILL BE CARRIED OUT BY THE
LOCAL POLICE AND FIRE DEPARTMENTS.
4.ABSORBENT MATERIALS, WHICH ARE USED IN CLEANING UP SPILLED
MATERIALS, WILL BE DISPOSED OF IN A MANNER SUBJECT TO THE
APPROVAL OF INDIANA DEPARTMENT OF ENVIRONMENTAL
MANAGEMENT.
5.FLUSHING OF SPILLING MATERIALS WITH WATER WILL NOT BE
PERMITTED UNLESS SO AUTHORIZED BY THE INDIANA DEPARTMENT
OF ENVIRONMENTAL MANAGEMENT.
B14:MONITORING AND MAINTENANCE GUIDELINES FOR POLLUTION
PREVENTION MEASURES.
SILT FENCE (SEDIMENT FENCE)
1.REQUIREMENTS: LIMIT WATERSHED AREA TO 1/4 ACRE PER 100 FT.
OF FENCE, FURTHER RESTRICTED BY SLOPE STEEPNESS.
2.LOCATION: FENCE NEARLY LEVEL, APPROXIMATELY FOLLOWING THE
LAND CONTOUR, AND AT LEAST 10 FT. FROM TOE OF SLOPE TO
PROVIDE A BROAD, SHALLOW SEDIMENT POOL.
INSTALLATION REQUIREMENTS:
1.TRENCH: 8 INCH MINIMUM DEPTH, FLAT-BOTTOM OR V-SHAPED,
FILLED WITH COMPACTED SOIL OR GRAVEL TO BURY LOWER
PORTION OF SUPPORT WIRE AND/OR FENCE FABRIC.
2.SUPPORT POSTS: 1-1/4" X 1-1/4" HARDWOOD POSTS SET AT LEAST 1
FOOT DEEP.
3.SPACING OF POSTS: 8 FOOT MAXIMUM IF FENCE SUPPORTED BY
WIRE, 6 FOOT FOR EXTRA-STRENGTH FABRIC WITHOUT WIRE
BACKING.
4.FENCE HEIGHT: HIGH ENOUGH SO DEPTH OF IMPOUNDED WATER
FOES NOT EXCEED 1-1/2 FOOT AT ANY POINT ALONG THE FENCE.
5.SUPPORT WIRE (OPTIONAL): 14 GAUGE, 6 INCH MESH WIRE FENCE
(NEEDED IF USING STANDARD-STRENGTH FABRIC).
6.FENCE FABRIC: WOVEN OR NON-WOVEN GEOTEXTILE FABRIC WITH
SPECIFIED FILTERING EFFICIENCY AND TENSILE STRENGTH AND
CONTAINING UV INHIBITORS AND STABILZERS TO ENSURE 6-MONTH.
MINIMUM LIFE AT TEMPERATURES 0-120 DEGREES FAHRENHEIT.
MAINTENANCE:
1.INSPECT THE SILT FENCE PERIODICALLY AND AFTER EACH STORM
EVENT.
2.IF THE FENCE FABRIC TEARS, STARTS TO DECOMPOSE, OR IN ANY
WAY BECOMES INEFFECTIVE, REPLACE THE AFFECTED PORTION
IMMEDIATELY.
3.REMOVE DEPOSITED SEDIMENT WHEN IT REACHES HALF THE
HEIGHT OF THE FENCE AT ITS LOWEST POINT OR IS CAUSING THE
FABRIC TO BULGE.
4.TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEAN
OUT.
5.AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED,
REMOVE THE FENCE AND SEDIMENT DEPOSITS, BRING THE
DISTURBED AREA TO GRADE AND STABILIZE.
EROSION CONTROL BLANKET
1.MATERIAL: AS SPECIFIED ON PLANS OR APPROVED EQUAL.
2.ANCHORING: PER MANUFACTURER'S RECOMMENDATIONS FOR
INTENDED USE OR PER PLAN SPECIFICATIONS.
INSTALLATION REQUIREMENTS:
1.SELECT THE TYPE AND WEIGHT OF EROSION CONTROL BLANKET AS
DIRECTED ON PLANS.
2.GRADE THE SITE AS SPECIFIED IN CONSTRUCTION PLANS.
3.ADD TOPSOIL WHERE APPROPRIATE.
4.PREPARE THE SEEDBED, FERTILIZE (AND LIME, IF NEEDED), AND
SEED THE AREA IMMEDIATELY AFTER GRADING.
5.FOLLOWING MANUFACTURER'S INSTRUCTIONS, LAY THE BLANKETS
ON THE SEEDED AREA SUCH THAT THE ARE IN CONTINUOUS
CONTACT WITH THE SOIL AND THAT THE UPSLOPE OR UPSTREAM
ONES OVERLAP THE LOWER ONES BY AT LEAST 8 INCHES.
6.TUCK THE UPPERMOST EDGE OF THE UPPER BLANKETS INTO A
CHECK SLOT (SILT TRENCH), BACKFILL WITH SOIL, AND TAMP DOWN.
7.ANCHOR THE BLANKETS AS SPECIFIED BY THE MANUFACTURER OR
AS SPECIFIED IN THE PLANS.
MAINTENANCE:
1.DURING VEGETATIVE ESTABLISHMENT, INSPECT AFTER EACH
STORM EVENT FOR ANY EROSION BELOW THE BLANKET.
2.IF ANY AREAS SHOW EROSION, PULL BACK THAT PORITON OF THE
BLANKET COVERING IT, RE-SEED THE AREA AND RELAY AND STAPLE
THE BLANKET.
3.AFTER VEGETATIVE ESTABLISHMENT CHECK THE TREATED AREA
PERIODICALLY.
TEMPORARY CONSTRUCTION ENTRANCE/EXIT PAD
REQUIREMENTS:
1.THE CONSTRUCTION ENTRANCE SHALL BE LOCATED OFF OF 116TH
STREET. IF MUDDY CONDITIONS RESULT IN TRACKING ON ROAD,
CLEAN UP IMMEDIATELY AND ADD "WHEEL WASH AREA".
2.MATERIAL FOR GRAVEL CONSTRUCTION ENTRANCE AND/OR WHEEL
WASH AREA: 2-3 INCHES OF WASHED STONE (INDOT CA #2) OVER A
STABLE FOUNDATION. THICKNESS: 8-INCH MINIMUM.
3.WIDTH: 24 FEET MINIMUM OR FULL WIDTH OF ENTRANCE/EXIT
ROADWAY, WHICHEVER IS GREATER.
4.LENGTH: 100 FEET MINIMUM.
5.WASHING FACILITY: LEVEL AREA WITH 3-INCH WASHED STONE
MINIMUM OR A COMMERCIAL ROCK, AND WASTE WATER DIVERTED
TO A PROTECTED AREA SUCH AS A SEDIMENT TRAP, BASIN, OR
AREA PROTECTED BY COIR LOGS.
6.GEOTEXTILE FABRIC UNDERLINER: MAY BE USED UNDER WET
CONDITIONS OR WITH SOILS WITH A HIGH SEASONAL WATER TABLE
TO PROVIDE GREATER BEARING STRENGTH.
INSTALLATION REQUIREMENTS:
1.AVOID LOCATING ON STEEP SLOPES OR AT CURVES IN PUBLIC
ROADS.
2.REMOVE ALL VEGETATION AND OTHER OBJECTIONABLE MATERIAL
FROM THE FOUNDATION AREA. GRADE AND CROWN FOR POSITIVE
DRAINAGE.
3.IF SLOPE TOWARDS THE ROAD EXCEEDS 2%, CONSTRUCT A 6-8 INCH
HIGH WATER BAR (RIDGE) WITH 3:1 SIDE SLOPES ACROSS THE DRIVE
AREA ABOUT 15 FEET FROM THE ENTRANCE TO DIVERT RUNOFF
AWAY FROM THE ROAD INTO PROTECTED SEDIMENT BASINS.
4.INSTALL PIPE UNDER THE DRIVE IF NEEDED TO MAINTAIN PROPER
PUBLIC ROAD DRAINAGE.
5.PLACE GEOTEXTILE FABRIC ON THE GROUND FOUNDATION PRIOR
TO STONE PLACEMENT TO IMPROVE STABILITY.
6.PLACE STONE TO DIMENSIONS AND GRADE SHOWN IN THE EROSION
CONTROL PLAN, LEAVING THE SURFACE SMOOTH AND SLOPED FOR
DRAINAGE.
7.DIVERT ALL SURFACE RUNOFF AND DRAINAGE FROM THE STONE
DRIVE TO A SEDIMENT TRAP OR BASIN.
MAINTENANCE:
1.INSPECT ENTRANCE DRIVE AND SEDIMENT DISPOSAL AREA WEEKLY
AND AFTER STORM EVENTS OR HEAVY USE.
2.RESHAPE DRIVE AS NEEDED FOR DRAINAGE AND RUNOFF CONTROL.
3.TOP DRESS WITH CLEAN STONE AS NEEDED.
4.IMMEDIATELY REMOVE MUD AND SEDIMENT TRACKED OR WASHED
ONTO PUBLIC ROADS BY BRUSHING OR SWEEPING. FLUSHING
SHOULD ONLY BE USED IF THE WATER IS CONVEYED INTO A
SEDIMENT TRAP OR BASIN.
5.REPAIR AND BROKEN ROAD PAVEMENT IMMEDIATELY.
RIPRAP
REQUIREMENTS:
1.ROCK: HARD, ANGULAR AND WEATHER-RESISTANT, HAVING A
SPECIFIC GRAVITY OF AT LEAST 2.5.
2.GRADATION: WELL-GRADED STONE, 50% (BY WEIGHT) SHOULD BE
LESS THAN 3 INCHES.
3.FILTER: USE GEOTEXTILE FABRIC FOR STABILIZATION AND
FILTRATION OR SAND/GRAVEL LAYER PLACED UNDER ALL
PERMANENT RIPRAP INSTALLATIONS.
4.SLOPE: 2:1 OR FLATTER, UNLESS APPROVED IN THE EROSION AND
SEDIMENT CONTROL PLAN.
5.MINIMUM THICKNETSS: THREE TIMES THE SPECIFIED D50 STONE
DIAMETER.
INSTALLATION REQUIREMENTS:
SUBGRADE PREPARATION:
1.REMOVE BRUSH, TREES, STUMPS, AND OTHER DEBRIS.
2.EXCAVATE ONLY DEEP ENOUGH FOR BOTH FILTER AND RIPRAP;
OVER-EXCAVATION INCREASES THE AMOUNT OF SPOIL
CONSIDERABLY.
3.COMPACT ANY FILL MATERIAL TO THE DENSITY OF THE
SURROUNDING UNDISTURBED SOIL.
4.CUT A KEYWAY IN STABLE MATERIAL AT THE BASE OF THE SLOPE TO
REINFORCE THE TOE; KEYWAY DEPTH SHOPULD BE 1.5 TIMES THE
DESIGN THICKNESS OF THE RIPRAP AND SHOULD EXTEND A
HORIZONTAL DISTANCE EQUAL TO THE DESIGN THICKNESS.
5.SMOOTH THE GRADED FOUNDATION.
FILTER PLACEMENT:
1.IF USING GEOTEXTILE FABRIC, PLACE IT ON THE SMOOTHED
FOUNDATION, OVERLAP THE EDGES AT LEAST 12 INCHES, AND
SECURE WITH ANCHOR PINS SPACED EVERY 3 FOOT ALONG THE
OVERLAP.
2.IF USING A SAND/GRAVEL FILTER, SPREAD THE WELL-GRADED
AGGREGATE IN A UNIFORM LAYER TO THE REQUIRED THICKNESS (6
INCH MAXIMUM); IF TWO OR ORE LAYERS ARE SPECIFIED, PLACE
THE LAYER OF SMALLER GRADATION FIRST, AND AVOID MIXING THE
LAYERS.
RIPRAP PLACEMENT:
1.IMMEDIATELY AFTER INSTALLING THE FILTER, ADD THE RIPRAP TO
THE FULL THICKNESS IN ONE OPERATION. (DO NOT DUMP THROUGH
CHUTES OR USE ANY METHOD THAT CAUSES SEGREGATION OF
ROCK SIZES OR THAT WILL DISLODGE OR DAMAGE THE UNDERLYING
FILTER MATERIAL).
2.IF FABRIC IS DAMAGED, REMOVE THE RIPRAP AND REPAIR BY
ADDING ANOTHER LAYER OF FABRIC, OVERLAPPING THE DAMAGED
AREA BY 12 INCHES.
3.PLACE SMALLER ROCK IN VOIDS TO FORM A DENSE, UNIFORM,
WELL-GRADED MASS. (SELECTIVE LOADING AT THE QUARRY AND
SOME HAND PLACEMENT MAY BE NEEDED TO ENSURE AN EVEN
DISTRIBUTION OF ROCK MATERIAL).
4.BLEND THE ROCK SURFACE SMOOTHLY WITH THE SURROUNDING
AREA TO ELIMINATE PROTRUSIONS OR OVERFALLS.
MAINTENANCE:
1.INSPECT PERIODICALLY FOR DISPLACED ROCK MATERIALS,
SLUMPING, AND EROSION AT EDGES, ESPECIALLY DOWNSTREAM OR
DOWNSLOPE. (PROPERLY DESIGNED AND INSTALLED RIPRAP
USUALLY REQUIRES VERY LITTLE MAINTENANCE IF PROMPTLY
REPAIRED).
B15:EROSION AND SEDIMENT CONTROL SPECIFICATIONS FOR
INDIVIDUAL BUILDING LOTS: NOT APPLICABLE.
STORMWATER POLLUTION
PREVENTION CHECKLIST C
C1:DESCRIPTION OF POLLUTANTS AND THEIR SOURCES ASSOCIATED
WITH THE PROPOSED LAND USE: SILT AND SEDIMENT FROM
EXPOSED SOILS, LEAVES, MULCH, VEHICULAR SOURCES SUCH AS
LEAKING FUEL OR OIL, BRAKE FLUID, BRAKE DUST, GREASE,
ANTIFREEZE, METALS, RUBBER FRAGMENTS, ROAD GRIT, SALTS AND
SANDS, CONSTRUCTION TRASH AND DEBRIS, FERTILIZERS,
HOUSEHOLD ITEMS INCLUDING BUT NOT LIMITED TO CLEANING
AGENTS, CHEMICALS, PAINT, MISCELLANEOUS HOME IMPROVEMENT
MATERIALS, TOYS, CLOTHING AND ANIMAL WASTE, ELEVATED
STORM RUNOFF TEMPERATURES, ACID RAIN, PESTICIDES AND
PATHOGENS.
C2:SEQUENCE DESCRIBING STORMWATER QUALITY MEASURE
IMPLEMENTATION.
1.INSPECT AND MAINTAIN ALL EROSION CONTROL MEASURES AS
DETAILED IN THE STORMWATER POLLUTION PREVENTION
MEASURES MAINTENANCE REQUIREMENTS BEGINNING
IMMEDIATELY AFTER INSTALLATION AND CONTINUING UNTIL
VEGETATION HAS BEEN SUFFICIENTLY ESTABLISHED AND ALL
CONSTRUCTION ACTIVITY IS COMPLETE.
2.REMOVE ALL INDIVIDUAL INLET PROTECTION AND COIR LOG CHECK
DAMS, SILT FENCES, ETC. ONLY AFTER SEEDING AND SUFFICIENT
VEGETATIVE GROWTH HAS BEEN ESTABLISHED IN EACH AREA TO A
POINT WHERE SEDIMENT/POLLUTANTS WILL NOT ENTER THE
DOWNSTREAM DITCH AND CREEK SYSTEM.
3.IT IS RECOMMENDED THAT ANY PROPOSED WETLAND AREA AND
PLANTINGS (IF ANY) BE CONSTRUCTED/PLACED AFTER FINAL
GRADING AND SUFFICIENT VEGETATIVE GROWTH HAS BEEN
ESTABLISHED TO A POINT WHERE SEDIMENT/POLLUTANTS WILL NOT
ENTER THE WETLANDS.
C3:DESCRIPTION OF PROPOSED POST-CONSTRUCTION STORMWATER
QUALITY MEASURES: SITE AND FACILITY DESIGN FOR STORMWATER
QUALITY PROTECTING ON THIS EMPLOYS A MULTI-LEVEL STRATEGY
CONSISTING OF:
1.CONTROLLING SOURCES OF POLLUTANTS
2.TREATING CONTAMINATED STORMWATER RUNOFF BEFORE
DISCHARGING IT INTO THE ADJACENT REGULATED DRAIN.
STORMWATER QUALITY MEASURES FOR REDUCING, ELIMINATING OR
CONTROLLING POLLUTANTS (SOURCE CONTROLS) INCLUDE:
1.VEGETATION FILTER STRIP WITH INFILTRATION TRENCH: THIS BMP
WILL FILTER AND ENCOURAGE INFILTRATION WHILE RUNOFF IS STILL
IN SHEET FLOW, AND WILL FUNCTION SIMILARLY TO A
BIOINFILTRATION AREA WITH NO SURFACE STORAGE.
2.WET DETENTION POND. WET DETENTION POND BMP
FUNCTIONALITY WILL BE ASSISTED BY INSTALLATION OF PROPOSED
POND AERATORS (SEE SHEET C117.)
3.VEGETATED SWALES
4.OUTLET PROTECTION & VELOCITY DISSIPATION DEVICES
IT IS THE INTENT OF THIS PLAN THAT THE IMPLEMENTATION OF THE
ABOVE DESCRIED STORMWATER QUALITY MEASURES BE EXECUTED IN
ACCORDANCE OF RULE 5 STORMWATER QUALITY.
C4:LOCATION, DIMENSIONS, SPECIFICATIONS AND CONSTRUCTION
DETAILS OF STORMWATER QUALITY MEASURES: SEE PLAN SHEETS
C117 THROUGH C121.
C5:DESCRIPTION OF MAINTENANCE GUIDELINES AND PROPOSED
WATER QUALITY MEASURES: SEE ATTACHED BMP OPERATIONS
AND MAINTENANCE MANUAL.
SOILS MAP
BR:BROOKSTON SILTY CLAY LOAM, 0 TO 2 PERCENT SLOPES
CrA:CROSBY SILT LOAM, FINE-LOAMY SUBSOIL, 0 TO 2 PERCENT SLOPES
FLOOD MAP
MAP ABOVE PER FEMA FIRMETTE #18057C0205G, EFFECTIVE ON 11/19/2014
·PROJECT OUTSIDE OF FLOOD HAZARDS
PROJECT
LOCATION
1
STORMWATER PERMIT RESUBMIT 05/04/181
DRIP LINE
TREE PROTECTION
FENCE, 6' HIGH CHAIN
LINK
EXISTING GRADE
DIRECT BURIED POST
DRIPLINE
DIMENSION
VARIES
STAINLESS STEEL
LOCKING BAND
GALVANIZED STEEL FRAME LIFT HANDLES
OVERFLOW FEATURE
GEOTEXTILE FILTER BAG
WITH REINFORCED
POLYESTER OUTER MESH
NOTE:
TEMPORARY INLET SEDIMENT FILTER TO BE INSTALLED ON ALL CATCH BASINS AND STORM
INLETS. INLET FILTER TO BE ROUND IPP INLET FILTER AS MANUFACTURED BY INLET & PIPE
PROTECTION, INC (847-722-0690) OR APPROVED OTHER. CLEAN FILTER AS NEEDED.
ROUND INLET FILTER
Stormwater Pollution Prevention
Details
0'40'20'10'
SCALE:
C501
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
NOT TO SCALE
SILT FENCE1 NOT TO SCALE
NPDES POSTING BOX2 NOT TO SCALE
STABILIZED CONSTRUCTION ENTRANCE3
NOT TO SCALE
TREE PROTECTION FENCE4
NOT TO SCALE
TEMPORARY SEED MIX & SCHEDULE5 NOT TO SCALE
EROSION CONTROL BLANKET6
NOT TO SCALE
CONCRETE WASHOUT7
NOT TO SCALE
INLET PROTECTION FILTER8
150'
M
I
N
.
O
R
A
S
SIT
E
A
L
L
O
W
S
VARIES (9'-0" MIN.)
SEE LAYOUT PLAN
VARIES (9'-0" MIN.)
SEE LAYOUT PLAN
℄ ROADWAY
2" BITUMINOUS SURFACE COURSE
2" BITUMINOUS BINDING COURSE
8" AGGREGATE BASE
(INDOT #53)
FLUSH CONCRETE CURB
SEE GRADING PLANS FOR CONTINUATION
2'-0"2'-0"
WOODEN GUARDRAIL
SEE LAYOUT PLAN FOR LOCATION
1.00% MIN.1.00% MIN.
1'-6"
TYP.
INDOT SUBGRADE TREATMENT IIA,
AS DIRECTED IN FIELD BY GEOTECH
VARIES (9'-0" MIN.)
SEE LAYOUT PLAN
VARIES (9'-0" MIN.)
SEE LAYOUT PLAN 2'-0"
℄ ROADWAYWWF 6 X 6, W2.9 X W2.9 AT MID DEPTH
6" AGGREGATE BASE
(INDOT #53)
FLUSH CONCRETE CURB
OR
CONCRETE BARRIER CURB
SEE LAYOUT PLAN FOR LOCATION
SEE GRADING PLANS
FOR CONTINUATION
2'-0"
1.00% MIN.1.00% MIN.
EXPANSION JOINT ,TYP.
3" TYP.
8" CONCRETE
- SEE LAYOUT PLANS FOR SCORING
- REFER TO SPECIFICATIONS FOR CONCRETE PATTERN
INDOT SUBGRADE
TREATMENT IIA, AS
DIRECTED IN FIELD
BY GEOTECH
CONCRETE
4" AGGREGATE BASE
(INDOT #53)
36"4"12"24"
ROADWAY PAVEMENT
SEE LAYOUT PLANS FOR TYPE
1/4" / FT
#4 BAR CONTINUOUS, TYP.
4"4"
EXISTING GRADE, SEE
GRADING PLANS
FOR CONTINUATION 3"3/4" R
CONCRETE
4" AGGREGATE BASE
(INDOT #53)
6"3/4" R
6"1/4" / FT
36"
24"
4"4"
#4 BAR CONTINUOUS, TYP.
EXISTING GRADE,
SEE GRADING PLANS
FOR CONTINUATION
ROADWAY PAVEMENT
SEE LAYOUT PLANS FOR TYPE
4"12"3"3/4" R
CONCRETE
4" AGGREGATE BASE
(INDOT #53)
6"
3/4" R
6"1/4" / FT
VARIES - MIN. 18" - MAX - 48"
SEE LAYOUT PLANS FOR GUTTER WIDTH
4"4"
#4 BAR CONTINUOUS, TYP.
ROADWAY PAVEMENT
SEE LAYOUT PLANS FOR TYPE
4"12"3"EXPANSION JOINT , TYP.
3"
PROVIDE EXPANSION JOINT
AND DOWELS WHERE BACK
OF CURB MEETS PAVING
2.08%1.00%
32'-0" - SEE LANDSCAPE PLANS FOR PLANTING4'-0"26'-0"2'-0"
CENTRAL ISLAND
MINIMUM 18" TOPSOIL
CONCRETE REVERSE PITCH
BARRIER CURB
SEE GRADING PLANS
FOR CONTINUATION
CONCRETE ROLL CURB
AND GUTTER
HEAVY DUTY CONCRETE PAVING
FLUSH CONCRETE CURB
2'-0"℄ ISLAND
12"24"6"LANDSCAPE DITCH
CROWN HIGH POINT ELEV.: 906.95
2.08%1.00%
4'-0"26'-0"2'-0"
LANDSCAPE UNDERDRAIN
CLEANOUT
MIN. 1'EXPANSION JOINT ,TYP.
EDGE OF PAVEMENT ELEV.: 905.05 (TYP.)
BACK OF CURB ELEV.: 905.38 (TYP.)
BACK OF CURB ELEV.: 905.95 (TYP.)
24"
4"10"10"6" R1' R3"10"14"#4 BAR CONTINUOUS, TYP.
4"4"
CONCRETE
4" AGGREGATE BASE
(INDOT #53)
PROVIDE EXPANSION JOINT
AND DOWELS WHERE BACK
OF CURB MEETS PAVING
EXPANSION JOINT, TYP.
3"
9'-0" MIN.
PAINTED HANDICAP
SYMBOL PER INDIANA
STANDARDS, TYP.
4" WIDE YELLOW PAINTED
STRIPE, TYP.18'-0"NOTE: ALL BARRIER FREE PAVEMENT
SURFACES SHALL NOT EXCEED 2%
SLOPE IN ANY DIRECTION
CONCRETE RIBBON CURB
9'-0" MIN.
4" WIDE WHITE PAINTED, TYP.PLAN
ELEVATION SECTION
CL
10"2"8"
3"4"4"
10"11"
4"3"7 1/2"25
8"25
8"
6"
6"6"5 1/2"11"3'-0"
MIN. REINF.
2-#5 x 5'-6
1" DIA. HOLE FOR 3/4 " x 30" LG.
STEEL ANCHOR - 2 PER BUMPER
PRECAST CONCRETE
CONCRETE CURB
4" AGGREGATE BASE
(INDOT #53)
(2) #4 BAR CONTINUOUS, TYP.
FINISIHED GRADE,
SEE GRADING AND
LANDSCAPE PLANS
FOR CONTINUATION
PROVIDE THICKENED EDGE CONCRETE
PAVING AT BARRIER CURB INTERFACE
SEE LAYOUT PLANS FOR
TYPE OF ADJACENT PAVING 6"6" TYP.1'-6"ISOLATION JOINT AND DOWEL
WHERE BARRIER CURB MEETS
CONCRETE PAVING
Site Details
C502
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SCALE: 1" = 5'
ASPHALT PAVEMENT1 SCALE: 1" = 5'
HEAVY DUTY CONCRETE PAVING2
SCALE: 1" = 5'
ROUNDABOUT SECTION3
SCALE: 1" = 1'
FLUSH CURB AND GUTTER4 SCALE: 1" = 1'
CONCRETE CURB AND GUTTER5 SCALE: 1" = 1'
CONCRETE ROLL CURB AND GUTTER6 SCALE: 1" = 1'
REVERSE PITCH CURB AND GUTTER7
NOT TO SCALE
ADA PARKING STRIPING9 SCALE: 1/2" = 1'
CONCRETE WHEELSTOP10SCALE: 1" = 1'
CONCRETE BARRIER CURB8
6'-0", TYP.
LIMESTONE - BROWN
SIZE PER INDOT NO.73
WITH SURFACE STABILIZER
FILTER FABRIC
AGGREGATE BASE
(INDOT #53)
SUBGRADE 3"6"TOPSOIL
AGGREGATE TRAIL
SUBGRADE
CONCRETE WALK
AGGREGATE BASE
31
2"3"2"EXPANSION JOINT WITH 6" SMOOTH
STEEL DOWEL @ 36" O.C., SLEEVE
ONE END
SUBGRADE
CONCRETE WALK, PROVIDE
THICKENED EDGE AT BACK
OF CURB
AGGREGATE BASE 1'-0"RIBBON CURB WITH BARRIER CURB, SEE
PLANS FOR LOCATIONS AND
REINFORCEMENT
1'-0"4"1
1
EXPANSION JOINT WITH 6" SMOOTH
STEEL DOWEL @ 36" O.C., SLEEVE
ONE END
SUBGRADE
CONCRETE WALK, PROVIDE
THICKENED EDGE AT BACK
OF CURB
AGGREGATE BASE 1'-0"RIBBON CURB, SEE PLANS FOR LOCATIONS
1'-0"4"1
1
(2) #4 BAR CONTINUOUS
(2) #4 BAR CONTINUOUS
ENGINEERED WOOD PLAY
SURFACING
FILTER FABRIC
DRAIN AGGREGATE
1% MIN. SLOPE TO
UNDERDRAIN
SUBGRADEPERABOVE4" MIN.ENGINEERED WOOD PLAY SURFACE
CRITICAL FALL HEIGHT
ZONE TOTAL THICKNESS
0'-0"6"
5'-0"8"
6'-0"10"
9'-0"1'-0"
NOTE:
CRITICAL FALL HEIGHTS TO DETERMINE
THICKNESS OF PLAY SURFACING.
PREPARED SUBGRADE 4" COMPACTED SUBBASE
5" CONCRETE PAVEMENTMEDIUM BROOM FINISH
6" X 6" WWF W2.9 AT MID-DEPTH
15" TOOLED CONTROL JOINT,
THEN SAW JOINT TO 14 PAVEMENT DEPTH
14" RADIUS TYP.
CONCRETE PAVEMENT - SEE DETAIL
12"JOINT SEALANT
TOP OF PAVEMENT
PREFORMED
EXPANSION
JOINT
MATERIAL
14" RADIUS 14"BACKER ROD
CL
NOTE: EXPANSION JOINTS
SHALL BE LOCATED WHERE
CONCRETE PAVEMENT
ADJOINS BUILDING FACE AND
WALLS WITH FROST FOOTINGS
AND ALL FIXED OBJECTS, AND
AS REQUIRED BY
SPECIFICATIONS.
8"
CONCRETE PAVEMENT
(2) #5 REBAR, CONTINUOUS
COMPACTED AGGREGATE BASE
PREPARED SUBGRADE
8"1'-3"R
1
"
SEE PLANS FOR ADJACENT
MATERIAL
BIKE LOOP
·MODEL: SARIS CYCLING GROUP
MODEL # 2213 - 2 BIKE FM BIKE
DOCK OR APPROVED EQUAL
·COLOR: BLACK
·FINISH: POWDERCOAT
MOUNTING PLATE, ATTACHMENT AND
HARDWARE PER MANUFACTURER.
INSTALL PER MANUFACTURER'S
SPECIFICATIONS
CONCRETE WALK 2'-8"2'-6"
Site Details
0'40'20'10'
SCALE:
C503
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SCALE: 1" = 1'
STABILIZED AGGREGATE TRAIL1 SCALE: 1" = 1'
CONCRETE PAVEMENT2
SCALE: 1" = 1'
CONCRETE WALK AND CURB INTERFACE5 SCALE: 1" = 1'
CONCRETE WALK AND AGGREGATE TRAIL INTERFACE6
SCALE: 1" = 1'
ENGINEERED WOOD CHIP SURFACING8
SCALE: 1:1
ISOLATION (EXPANSION) JOINT4
NOT TO SCALE
CONTROL JOINT3
SCALE: 1" = 1'
THICKENED EDGE CONCRETE PAVEMENT7 SCALE: 1" = 1'
BIKE RACK9
10'-0"6'-0"4"1'-10"1'-6"AGGREGATE BASE, PROVIDE
4" MIN AGGREGATE BASE,
ALL SIDES
SUBGRADE
EDGE CONDITION
3'-73
4"
MIN.
SPACER BLOCK3'-0"3'-6"8"8"4"8"8"3
4" Ø GALV. BOLT
WITH NUT & WASHER
(COUNTERSUNK)
(2) 4" X 8" X 12'-0" RAIL
12" X 12" X 6'-6" POST
2" CHAMFER ON TOP
6'-0" O.C. (TYP.)
1'-6"
WOOD GUARDRAIL NOTES:
1) ALL LUMBER TO BE PRESSURE TREATED.
2) POST TO BE AUGAR INTO GROUND.
3) PROVIDE BURIED END CONDITION, TYP. UNLESS
OTHERWISE NOTED (2/C504)
(2) 4" X 8" X 12'-0"
RAIL; CUT INTO POST
12" X 12" X 6'-6" POST
2" CHAMFER ON TOP
CUT SLOTS TO RECEIVE RAIL
34" Ø GALV. BOLT WITH NUT & WASHER
(COUNTERSUNK)
FINISHED GRADEFINISHED GRADE
SECTION FRONT ELEVATION:
GRAVEL COLLAR
18"3'-6" MIN.5'-0" MAX.3'-6"31
2"31
2"312"EMBED POSTS
4"X6" CURB AND BLOCK
2"X8" RAIL
2"X4" RAIL
2"X6" RAIL
2"X6" RAIL
2"X6" CAP (ROUND EDGES)
3
4" #9 (10 GA.) STAINLESS
EXPANDED METAL, TYPE 304
STANDARD, ORIENT WITH SMALL
OPENING RUNNING VERTICAL.
SHOTBLAST TO REMOVE ALL BURS
AND SHARP EDGES. POWDERCOAT
AND CLEAR COAT ALL SURFACES,
COLOR TO BE SELECTED.
NOTE:
1. ALL WOOD TO BE CEDAR, OR APPROVED EQUAL.
2. BASIS OF DESIGN IS THE EXISTING GUARDRAIL ON
THE WEST PARK POND BOARDWALK.
FINISHED GRADE 2'-11"3'-6" MIN.6"2'-0" DIA., MIN.
MANUAL RETRACTABLE BOLLARD
ISOLATION (EXPANSION) JOINT
ALL SIDES
CONCRETE PAVEMENT
CONCRETE FOUNDATION
EMBED PER MFTC'S STANDARDS2" PVC DRAIN PIPE
COMPACTED AGGREGATE BASE
Site Details
C504
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SCALE: 1/2" = 1'
GUARDRAIL TERMINUS2
SCALE: 1" = 1'
PEDESTRIAN GUARDRAIL3 SCALE: 1" = 1'
MANUAL RETRACTABLE BOLLARD4
SCALE: 1/4" = 1'
WOODEN GUARDRAIL1
GENERAL NOTES:
1. PROVIDE SHOP DRAWINGS SIGNED AND STAMPED BY INDIANA PROFESSIONAL
ENGINEER FOR ALL BOARDWALK ELEMENTS.
2. ENSURE POSITIVE SITE DRAINAGE BELOW AND THROUGH BOARDWALK SPANS.
3. TREADS AND BEAMS SHALL BE PRECAST BOARDWALK SYSTEM BY PERMATRAK, OR
APPROVED EQUAL. SUBMIT DETAILED SHOP DRAWINGS.
4. PRECAST ELEMENTS SHALL BE FREE OF CHIPS, CRACKS, AND SEAMS.
5. PRECAST ELEMENTS SHALL BE INTEGRAL COLOR WITH SANDBLAST FINISH. SUBMIT
COLOR AND FINISH SAMPLES FOR REVIEW.
6. PLACE
18" THICK RUBBER PAD BETWEEN BEAM & TREADS FOR UNEVEN BEARING
7. PROVIDE
14" CHAMFER ON ALL EXPOSED EDGES OF TREADS.
DESIGN DATA:
1. BOARDWALK SHALL BE DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD BRIDGE
DESIGN SPECIFICATIONS AND THE LRFD GUIDE SPECIFICATION FOR THE DESIGN OF
PEDESTRIAN BRIDGES.
1.1. DESIGN LIVE LOAD:
PEDESTRIAN LOADING - 90 PSF UNIFORM.
VEHICULAR LOADING - 5,000 LBS, 2,500 LBS PER AXLE WITH MIN 96" WHEELBASE
CASE 1 - H-5 TRUCK - 10,000 LBS TOTAL LOAD
2. ABUTMENTS SHALL BE DESIGNED FOR LATERAL EARTH PRESSURE, LIVE LOAD
SURCHARGE AND STRUCTURAL LOADS. ASSUMED ALLOWABLE BEARING PRESSURE:
2,500 PSF (CONTRACTOR TO VERIFY)
PRECAST CONCRETE TREAD
PRECAST CONCRETE BEAM (BELOW)
CONCRETE ABUTMENT
1'-0"VARIES, SEE PLANS1'-0"
SPACING FOR CONCRETE PIERS, PER MFCT.
CONCRETE PIERS WITH
PRECAST CONCRETE CAPS
RIVER ROCK CHANNEL
INSTALL DIRECTLY BELOW ALL
BOARDWALK TREADS
LIMESTONE BOULDERS AT ABUTMENTS
VARIES; SEE PLANS
1'-3"6" MIN.3'-6" MIN.16" TYP.
FINISHED GRADE
POLYURETHANE PINS IN
BEAM TO SECURE TO PIER
RIVER ROCK CHANNEL
INSTALL DIRECTLY BELOW ALL
BOARDWALK TREADS. SEE PLANS
FOR CONTINUATION OUTSIDE OF BOARDWALK
PRECAST CONCRETE PEDESTAL
CAP TO RECEIVE PINS FROM
BEAMS
PREPARED SUBGRADE
CONTINUOUS 1
8" THICK
RUBBER PAD BETWEEN
TREAD & BEAM FOR UNEVEN
BEARING
FINISH GRADE: ENSURE POSITIVE SITE
DRAINAGE BELOW BOARDWALK
PRECAST CONCRETE BEAM
PRECAST CONCRETE TREAD
CAST-IN-PLACE CONCRETE PIER
Site Details
0'40'20'10'
SCALE:
C506
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
1/2" = 1'
PRECAST CONCRETE BOARDWALK - ELEVATION1
1/2" = 1'
PRECAST CONCRETE BOARDWALK - SECTION2 1/2" = 1'
CONCRETE ABUTMENT3
1'-0"APPROX 1'-3"3'-6" MIN.3" MIN.3" MIN.2'-0" MIN.
ADJACENT PAVING (SEE LAYOUT & MATERIALS PLAN)
DOWELED EXPANSION JOINT @ ABUTMENT
DOWELS EVERY 12" O.C.
FORM OR FIELD CUT GROOVE IN ABUTMENT AS
NEEDED TO RECEIVE BOARDWALK TREADS
POLYURETHANE PINS IN BEAM TO SECURE
FORM OR FIELD CUT CHAMFERED GROOVE IN
ABUTMENT AS NEED TO RECEIVE BOARDWALK BEAM
PINS.
FINISHED GRADE
ENSURE POSITIVE SITE DRAINAGE BELOW AND
THROUGH BOARDWALK SYSTEM
#4 HORIZONTAL TIES @ 12" O.C. (MIN.)
#5 @ 12" O.C. (MIN.) - BOTH DIRECTIONS
REINFORCED CONCRETE ABUTMENT
COMPACTED BACKFILL
2000 PSF BEARING CAPACITY
AMEND SOIL AS DIRECTED BY ENGINEER1
1
*CONFIRM & VERIFY EXACT DEPTH OF
BOARDWALK SYSTEM PER MANUFACTURER
PRIOR TO ABUTMENT CONSTRUCTION
1'-2"1.00%4"WOODEN GUARDRAIL
RIBBON CURB
ASPHALT ROADWAY
RIPRAP
RIPRAP
COORDINATE LOCATION OF
WOODEN GUARDRAIL POSTS
WITH CULVERT PIPING
(2) 48 LF - 14"x23" ELLIPTICAL RCP @ 1.00%
TYPICAL PIPE PENETRATION
REINFORCING:
WALL AND REINFORCING IS SYMMETRICAL
ABOUT CENTERLINE
ADDITIONAL VERT. BAR
ON EACH SIDE OF
OPENING
ADDITIONAL HORZ. BAR TOP
AND BOTTOM OF OPENING,
5'-0" LONG
(4) 5'-0" LONG DIAGONAL
BARS AS SHOWN
NOTES:
1) ALL REINFORCING SHALL BE #4 BARS.
2) REINFORCING IS SYMMETRICAL ABOUT THE CENTERLINE. REINFORCING
SHOWN ON ONE SIDE OF CENTERLINE IS OMITTED ON THE OTHER SIDE
FOR CLARITY.
#4 @ 12" O.C. EACH
WAY.
TYPICAL WALL REINFORCING
#4 @ 12" O.C. EACH
WAY
TYPICAL CUT OFF WALL
REINFORCING:2'-0"1'-0"R10'-0"10"6"18'-0"
16'-0"4'-0"HEADWALL
CONCRETE BASE SLAB
END OF PIPE SHALL BE FLUSH
WITH HEAD WALL FACE (TYP.)1'-2"4"10"
6"6"6"1'-6"3/4" CHAMFER
FORM LINER TEXTURED FINISH
RCP-SEE GRADING
PLANS FOR I.E.
4" WIDE SMOOTH BAND AT TOP
RIPRAP
OPTIONAL
CONST. JNT.
STRUCTURAL BACKFILL
#4 @12" O.C.
#4 @12" O.C.
12" MIN.
GRANULAR FILL
#4 12" O.C.
EACH WAY
#4 @12" O.C.
(18" X 18" 'L' BAR)1'-0"Site Details
0'40'20'10'
SCALE:
C507
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SCALE: 1/4" = 1'
ENTRY CULVERT SECTION1
8'2'0' 4'
GRAPHIC SCALE
SCALE: 1/2" = 1'
ENTRY CULVERT HEADWALL - ELEVATION2 SCALE: 1/2" = 1'
ENTRY CULVERT HEADWALL - PLAN VIEW3 SCALE: 1/2" = 1'
ENTRY CULVERT HEADWALL - SECTION4
17'
CLEAR
PRECAST ARCH
SECTIONS
TOP OF FOOTING4' MIN.CLEAR6'-8 3/8"PROPOSED PROF DRIVE PROFILE
1'-0"4'-0"
12" TOPSOIL
CAST-IN-PLACE CONCRETE FOOTING
9'9'
VARIES
LAWN
2'2'PRECAST HEADWALL
TOP OF PRECAST ARCH SECTION
BOTTOM OF PRECAST ARCH SECTION
ELEV.=891.90
ELEV.=891.80
C OF PROF DR.
ELEV.= 903.5
L
APPROXIMATE STREAM BED PROFILE
AT CENTERLINE
18'
ROAD
CAST-IN-PLACE FOOTING4' MIN.CLEAR12" TOPSOIL
VEHICULAR GUARDRAIL PEDESTRIAN GUARDRAILVARIES
LAWN 10'
WALK
PRECAST WINGWALLS
57'
LENGTH
20' HEADWALLS17' WIDTH30' WING
WALLS
Site Details
0'40'20'10'
SCALE:
C507.1
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
1" = 5'
PRECAST ARCH CULVERT - SECTION1 1" = 5'
PRECAST ARCH CULVERT - SECTION2
DESIGN/BUILD PRECAST CONCRETE STRUCTURE SPECIFICATION
1. QUALITY ASSURANCE
THE CONTRACTOR SHALL DEMONSTRATE ADHERENCE TO THE STANDARDS SET FORTH IN THE NPCA QUALITY CONTROL
MANUAL. THE DESIGN/BUILD CONTRACTOR SHALL MEET EITHER SECTION 1.1 OR 1.2.
1.1 CERTIFICATION
THE DESIGN/BUILD CONTRACTOR SHALL BE CERTIFIED BY THE PRECAST/PRESTRESSED CONCRETE INSTITUTE PLANT CERTIFICATION
PROGRAM OR NATIONAL PRECAST CONCRETE ASSOCIATION'S PLANT CERTIFICATION PROGRAM PRIOR TO AND DURING PRODUCTION OF THE
PRODUCTS COVERED BY THIS SPECIFICATION.
1.2 QUALIFICATIONS, TESTING AND INSPECTION
2.1 THE DESIGN/BUILD CONTRACTOR SHALL HAVE BEEN IN THE BUSINESS OF PRODUCING PRECAST PRODUCTS SIMILAR TO THOSE
SPECIFIED FOR A MINIMUM OF THREE YEARS. CONTRACTOR SHALL MAINTAIN A PERMANENT QUALITY CONTROL DEPARTMENT OR RETAIN
AN INDEPENDENT TESTING AGENCY ON A CONTINUING BASIS. THE AGENCY SHALL ISSUE A REPORT, CERTIFIED BY A LICENSED
ENGINEER, DETAILING THE ABILITY OF THE DESIGN/BUILD CONTRACTOR TO PRODUCE QUALITY PRODUCTS CONSISTENT WITH INDUSTRY
STANDARDS.
2.2. THE DESIGN/BUILD CONTRACTOR SHALL SHOW THAT THE FOLLOWING TESTS ARE PERFORMED IN ACCORDANCE WITH THE ASTM
STANDARDS INDICATED. TESTS SHALL BE PERFORMED FOR EACH 150 CUBIC YARDS OF CONCRETE PLACED, BUT NOT LESS FREQUENTLY
THAN ONCE PER PRODUCTION RUN.
2.2.1 AIR CONTENT: C231 OR C173
2.2.2 COMPRESSIVE STRENGTH: C39, C497
2.3 THE DESIGN/BUILD CONTRACTOR SHALL PROVIDE DOCUMENTATION DEMONSTRATING COMPLIANCE WITH THIS SECTION TO THE
ARCHITECT/ENGINEER AT REGULAR INTERVALS OR UPON REQUEST.
2.4 THE OWNER'S REPRESENTATIVE MAY PLACE AN INSPECTOR IN THE PLANT WHEN THE PRODUCTS COVERED BY THIS SPECIFICATION ARE
BEING MANUFACTURED.
1.3 PERMISSIBLE VARIATIONS
1.3.1 BRIDGE UNITS
1.3.2 INTERNAL DIMENSIONS - THE INTERNAL DIMENSIONS SHALL VARY NOT MORE THAN
1 % FROM THE DESIGN DIMENSIONS NOR MORE THAN 1-1/2 INCHES WHICHEVER IS LESS. THE HAUNCH DIMENSIONS SHALL VARY NOT
MORE THAN 3/4 INCH FROM THE DESIGN DIMENSION.
1.3.3 SLAB AND WALL THICKNESS - THE SLAB AND WALL THICKNESS SHALL NOT BE LESS THAN THAT SHOWN IN THE DESIGN BY MORE THAN 1/4
INCH. A THICKNESS MORE THAN THAT REQUIRED IN THE DESIGN SHALL NOT BE CAUSE FOR REJECTION.
1.3.4 LENGTH OF OPPOSITE SURFACES - VARIATIONS IN LAYING LENGTHS OF TWO OPPOSITE SURFACES OF THE BRIDGE UNIT SHALL NOT BE
MORE THAN ½ INCH IN ANY SECTION, EXCEPT WHERE BEVELED ENDS FOR LAYING OF CURVES ARE SPECIFIED BY THE PURCHASER.
1.3.5 LENGTH OF SECTION - THE UNDERRUN IN LENGTH OF A SECTION SHALL NOT BE MORE THAN 1/2 INCH IN ANY BRIDGE UNIT.
1.3.6 POSITION OF REINFORCEMENT - THE MAXIMUM VARIATION IN POSITION OF THE REINFORCEMENT SHALL BE 1/2 INCH. IN NO CASE SHALL
THE COVER OVER THE REINFORCEMENT BE LESS THAN 1 1/2 INCHES FOR THE OUTSIDE CIRCUMFERENTIAL STEEL OR BE LESS THAN 1
INCH FOR THE INSIDE CIRCUMFERENTIAL STEEL AS MEASURED TO THE EXTERNAL OR INTERNAL SURFACE OF THE BRIDGE. THE
TOLERANCES OR COVER REQUIREMENTS DO NOT APPLY TO MATTING SURFACES OF THE JOINTS.
1.3.7 AREA OF REINFORCEMENT - THE AREAS OF STEEL REINFORCEMENT SHALL BE THE DESIGN STEEL AREAS AS SHOWN IN THE
MANUFACTURER'S SHOP DRAWINGS. STEEL AREAS GREATER THAN THOSE REQUIRED SHALL NOT BE CAUSE FOR REJECTION. THE
PERMISSIBLE VARIATION IN DIAMETER OF ANY REINFORCEMENT SHALL CONFORM TO THE TOLERANCES PRESCRIBED IN THE ASTM
SPECIFICATION FOR THAT TYPE OF REINFORCEMENT.
1.3.8 WINGWALLS AND HEADWALLS
1.3.9 WALL THICKNESS - THE WALL THICKNESS SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY MORE THAN 1/2 INCH.
1.3.10 LENGTH/HEIGHT OF WALL SECTIONS - THE LENGTH AND HEIGHT OF THE WALL SHALL NOT VARY FROM THAT SHOWN IN THE DESIGN BY
MORE THAN 1/2 INCH.
1.3.11 POSITION OF REINFORCEMENT - THE MAXIMUM VARIATION IN THE POSITION OF THE REINFORCEMENT SHALL BE 1/2 INCH. IN NO CASE
SHALL THE COVER OVER THE REINFORCEMENT BE LESS THAN 1 1/2 INCHES.
1.3.12 SIZE OF REINFORCEMENT - THE PERMISSIBLE VARIATION IN DIAMETER OF ANY REINFORCING SHALL CONFORM TO THE TOLERANCES
PRESCRIBED IN THE ASTM SPECIFICATION FOR THAT TYPE OF REINFORCING. STEEL AREA GREATER THAN THAT REQUIRED SHALL NOT
BE CAUSE FOR REJECTION.
1.4 WORKMANSHIP AND FINISH
THE BRIDGE UNITS, WINGWALLS, AND HEADWALLS SHALL BE SUBSTANTIALLY FREE OF FRACTURES. THE ENDS OF THE BRIDGE UNITS
SHALL BE NORMAL TO THE WALLS AND CENTERLINE OF THE BRIDGE SECTION, WITHIN THE LIMITS OF THE VARIATIONS GIVEN IN SECTION
1.3 ABOVE, EXCEPT WHERE BEVELED ENDS ARE SPECIFIED. THE FACES OF THE WINGWALLS AND HEADWALLS SHALL BE PARALLEL TO
EACH OTHER TO EACH OTHER; WITHIN THE LIMITS OF VARIATIONS GIVEN IN SECTION 1.3 ABOVE. THE SURFACE OF THE PRECAST
ELEMENTS SHALL BE A SMOOTH STEEL FORM OR TROWELED SURFACE. TRAPPED AIR POCKETS CAUSING SURFACE DEFECTS SHALL BE
CONSIDERED AS PART OF A SMOOTH, STEEL FORM FINISH.
GENERAL NOTES
1. BASIS OF DESIGN FOR PRECAST ARCH CULVERT IS CONSPAN 'O-SERIES' 0117, 17'
WIDTH BY 57' LENGTH BY 6'-8 3
8" RISE.
2. THE DESIGN/BUILD CONTRACTOR SHALL DESIGN THE BRIDGE STRUCTURE AND WALLS
IN ACCORDANCE WITH THE AASHTO BRIDGE DESIGN MANUAL. ALL BRIDGE DESIGN,
DRAWINGS, DETAILS & SPECIFICATIONS SHALL BE SEALED BY AN INDIANA REGISTERED CIVIL
ENGINEER. THE DESIGN/BUILD CONTRACTOR SHALL BE RESPONSIBLE FOR THE
STRUCTURE'S SUITABILITY TO THE EXISTING SITE CONDITIONS AND FOR THE HYDRAULIC
EVALUATION - - INCLUDING SCOUR AND CONFIRMATION OF SOIL CONDITIONS.
3. PRIOR TO THE CONSTRUCTION THE DESIGN/BUILD CONTRACTOR MUST VERIFY ALL
ELEVATIONS SHOWN THROUGH THE ARCHITECT/ENGINEER.
4. CONTRACTOR TO COORDINATE EMBEDMENT DEPTH AND ANCHORING DETAILS FOR
GUARDRAILS ARCH CULVERT SECTION, WHERE DEPTH IS LESS THAN INDICATED ON THE
GUARDRAIL DETAILS.
DESIGN DATA
DESIGN LOADING:
AASHTO BRIDGE DESIGN MANUAL
BRIDGE UNITS: HS20-44
HEADWALLS: EARTH PRESSURE ONLY
WINGWALLS: EARTH PRESSURE ONLY
DESIGN FILL HEIGHT: VARIES PER DRAWINGS WITH MINIMUM 1.60 FEET FROM TOP OF
CROWN TO TOP PAVEMENT AT ROAD CENTERLINE.
DESIGN METHOD: LOAD FACTOR PER AASHTO SPECIFICATION
ASSUMED NET ALLOWABLE SOIL BEARING PRESSURE: REFER TO GEOTECHNICAL REPORT.
ASSUMED GROSS ALLOWABLE SOIL BEARING PRESSURE: REFER TO GEOTECHNICAL
REPORT.
IT IS THE DESIGN/BUILD CONTRACTOR'S RESPONSIBILITY TO VERIFY THAT THE ACTUAL SITE
CONDITIONS AT THE TIME OF CONSTRUCTION ARE CONSISTENT WITH THE ASSUMED
ALLOWABLE SOIL BEARING PRESSURE WITH A GEOTECHNICAL INVESTIGATION FROM A
QUALIFIED GEOTECHNICAL ENGINEER.
MATERIALS
CONCRETE FOR FOOTINGS SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 4000 PSI.
REINFORCING STEEL FOR FOOTINGS SHALL CONFORM TO ASTM A615 OR A996 - GRADE 60.
BACKFILL
BACKFILL DETAILS AND REQUIREMENTS FOR ALL PRECAST CONCRETE STRUCTURE
ELEMENTS INDICATED ON THIS DRAWING ARE FOR REFERENCE PURPOSES ONLY. ACTUAL
BACKFILL REQUIREMENTS SPECIFIC TO THE PRECAST CONCRETE STRUCTURE IN THIS
PROJECT SHALL BE DETERMINED BY THE DESIGN/BUILD CONTRACTOR.
BACKFILL SHALL BE CONSIDERED AS ALL REPLACED EXCAVATION AND NEW EMBANKMENT
ADJACENT TO THE PRECAST CONCRETE STRUCTURE UNITS, WING WALLS, AND HEADWALLS.
BACKFILL IN FRONT OF WING WALLS SHALL BE CARRIED TO GROUND LINES SHOWN IN THE
PLANS.
1" = 10'
PRECAST ARCH CULVERT - PLAN3
NOT TO SCALE
GENERAL BACKFILL REQUIREMENTS4
VARIES: SEE LAYOUT AND MATERIALS PLANS
VARIES:SEE GRADINGPLANLIMESTONE BLOCK
CONCRETE PAVING
NOTE:
1. LIMESTONE BLOCK SIZES INDICATED ON
PLANS ARE APPROXIMATE. TOLERANCES
WILL BE 3"±, BASED ON AVAILABILITY OF
BLOCKS FROM SUPPLIER.
2. LIMESTONE BLOCKS SHALL BE
STANDARD GRADE, FULL COLOR BLEND,
AS PROVIDED BY INDIANA LIMESTONE
COMPANY, OR APPROVED EQUAL.
3. CONTRACTOR TO SUBMIT BLOCK
SAMPLES SHOWING FULL COLOR RANGE
OF MATERIALS.
LIMESTONE BLOCK BENCH
THICKENED EDGE CONCRETE PAVING1'-6"±2'-0"±
LEVEL LIMESTONE BASE TO PREVENT
MOVEMENT
NOTE:
1. LIMESTONE BLOCK SIZES
INDICATED ON PLANS ARE
APPROXIMATE. TOLERANCES WILL
BE 1"±, BASED ON AVAILABILITY OF
BLOCKS FROM SUPPLIER.
2. BLOCKS SHALL BE 4'-0" LENGTH
MIN.; 6'-0" LENGTH MAX.
3. LIMESTONE BLOCKS SHALL BE
STANDARD GRADE, FULL COLOR
BLEND, AS PROVIDED BY INDIANA
LIMESTONE COMPANY, OR
APPROVED EQUAL.
4. CONTRACTOR TO SUBMIT BLOCK
SAMPLES SHOWING FULL COLOR
RANGE OF MATERIALS.
RANGE: 3'-0" TO 4-0"
WIDTH & LENGTH
1'-6"±LIMESTONE BLOCK SEAT
CONCRETE PAVING OR 6"
COMPACTED SUBBASE WHERE
SHOWN IN NON-PAVED AREAS
LEVEL LIMESTONE BASE TO PREVENT
MOVEMENT
NOTE:
1. LIMESTONE BLOCK SIZES
INDICATED ON PLANS ARE
APPROXIMATE. HEIGHT
TOLERANCES WILL BE 1"±, BASED
ON AVAILABILITY OF BLOCKS FROM
SUPPLIER.
2. LIMESTONE BLOCKS SHALL BE
STANDARD GRADE, FULL COLOR
BLEND, AS PROVIDED BY INDIANA
LIMESTONE COMPANY, OR
APPROVED EQUAL.
3. CONTRACTOR TO SUBMIT BLOCK
SAMPLES SHOWING FULL COLOR
RANGE OF MATERIALS.
(4) - #4 REBAR
CONCRETE FOUNDATION
(2) - #4 TIES @ 12" O.C.
LIMESTONE BLOCK BOLLARD
CORE BLOCK TO RECEIVE SLEEVING
AND ANCHORING
3" DIA. SCH. 40 STEEL PIPE
ISOLATION (EXPANSION) JOINT, TYP.
34" NON SHRINK GROUT SETTING BED.
RAKE BACK 12" TO RECIEVE SEALANT.
4" SCH. 40 P.V.C. PIPE SLEEVE
SUBGRADE42" MIN.15" MIN.5"5"
℄
NOTE:
1.LIMESTONE BLOCK SIZES INDICATED ON PLANS ARE APPROXIMATE. HEIGHT TOLERANCES WILL BE 3"±,
BASED ON AVAILABILITY OF BLOCKS FROM SUPPLIER.
2. LIMESTONE BLOCKS SHALL BE STANDARD GRADE, FULL COLOR BLEND, AS PROVIDED BY INDIANA
LIMESTONE COMPANY, OR APPROVED EQUAL.
3. CONTRACTOR TO SUBMIT BLOCK SAMPLES SHOWING FULL COLOR RANGE OF MATERIALS.2'-6"±24" Ø
MIN. 3"
CLEAR
2'-6"±
STORMWATER CHAIN
SEE ARCHITECTURAL DRAWINGS
COMPACTED SUBBASE
1/4" X 6" EYE BOLT
CORE AND EPOXY INTO BLOCK.
NOTE:
1. LIMESTONE BLOCK SIZES INDICATED ON
PLANS ARE APPROXIMATE. TOLERANCES
WILL BE 3"±, BASED ON AVAILABILITY OF
BLOCKS FROM SUPPLIER.
2. LIMESTONE BLOCKS SHALL BE STANDARD
GRADE, FULL COLOR BLEND, AS PROVIDED
BY INDIANA LIMESTONE COMPANY, OR
APPROVED EQUAL. LARGE LIMESTONE
BOULDERS AS ALSO SUPPLIED BY INDIANA
LIMESTONE COMPANY MAY BE
ACCEPTABLE IF CONFORMING TO SIZES
INDICATED.
3. CONTRACTOR TO SUBMIT BLOCK SAMPLES
SHOWING FULL COLOR RANGE OF
MATERIALS.
4. DO NOT OVER-TIGHTEN STORM CHAIN TO
EYEBOLT.
FINISHED GRADE
1'-0"±1'-6"±
1
1
COMPACTED SUBBASE
LIMESTONE BOULDERS
SEE PLANS FOR LOCATION
NOTE:
1. LIMESTONE BOULDER SIZES SHALL BE
LARGE LANDSCAPE BOULDERS, AS
PROVIDED BY INDIANA LIMESTONE
COMPANY, OR APPROVED EQUAL.
2. LIMESTONE BOULDERS SHALL BE
STANDARD GRADE, FULL COLOR BLEND,
OR APPROVED EQUAL.
3. CONTRACTOR TO SUBMIT BLOCK SAMPLES
SHOWING FULL COLOR RANGE OF
MATERIALS.
FINISHED GRADE
3" MIN.8" - 12" ±
VARIES: SEE PLANS
1'-0"SEE LANDSCAPE DRAWINGS
FILTER FABRIC, ALL SIDES
RIVER ROCK
TOPSOIL
SUBGRADE
NOTE:
1. SEE SPECIFICATION SECTION 32
9300.2.2.B, FOR RIVER ROCK
MATERIAL AND SIZES.
1
1
COMPACTED SUBBASE
LIMESTONE BOULDERS
SEE PLANS FOR LOCATION
NOTE:
1. LIMESTONE BOULDER SIZES SHALL BE
LARGE LANDSCAPE BOULDERS, AS
PROVIDED BY INDIANA LIMESTONE
COMPANY, OR APPROVED EQUAL.
2. LIMESTONE BOULDERS SHALL BE
STANDARD GRADE, FULL COLOR BLEND,
OR APPROVED EQUAL.
3. CONTRACTOR TO SUBMIT BLOCK SAMPLES
SHOWING FULL COLOR RANGE OF
MATERIALS.
FINISHED GRADE
3" MIN.8" - 12" ±
POND TYPICAL H.W.E. (SEE GRADING
AND UTILITY PLANS FOR ELEVATION.)
Site Details
C508
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
SCALE: 1" = 1'
LIMESTONE SEAT1 SCALE: 1/2" = 1'
LIMESTONE BLOCK3
SCALE: 1" = 1'
LIMESTONE BOLLARD4
SCALE: 1" = 1'
LIMESTONE BOULDERS5
SCALE: 1" = 1'
LIMESTONE BENCH2
SCALE: 1" = 1'
LIMESTONE BLOCK STORM CHAIN ANCHOR6
SCALE: 1" = 1'
RIVER ROCK CHANNEL7 SCALE: 1" = 1'
CONVEYANCE WEIR REINFORCEMENT8
NOTES:
1. MEETS ADA REGULATIONS.
2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS.
3. DO NOT SCALE DRAWING.
18"5"27" ADA HEIGHT29"7"10" PIPE
OPTIONAL INTERNAL
SURFACE CARRIER
PF CONTROL
BUTTON
MDF RECOMMENDS
A 3" OR 4" OPEN
HUB DRAIN - BY
OTHERS
PET FOUNTAIN
WATER
C/L OF WASTE
SUPPLY LINE
REC. HB WITH
LOCK DOOR
30" MIN. CLEARANCE ADA 40"40"CONCRETE ABUTMENT
THICKENED EDGE CONCRETE
METAL GRATE WALKWAY & FRAME
FINISHED GRADE BELOW
SEE GRADING PLANS
VARIES, SEE PLANS1'-0"PER MFCT.12" TYP.GENERAL NOTES:
1. PROVIDE SHOP DRAWINGS SIGNED AND STAMPED BY INDIANA PROFESSIONAL
ENGINEER FOR ALL METAL GRATE WALKWAY ELEMENTS.
2. METAL GRATE WALKWAY IS INTENDED ONLY FOR PEDESTRIANS, NO VEHICULAR USE.
3. METAL GRATE AND FRAME TO MATCH STYLE OF TRENCH DRAIN (DETAIL #4, SHEET C511),
"JAMISON" STYLE AS PROVIDED BY URBAN ACCESSORIES, OR APPROVED EQUAL.
SECURE FRAME TO ABUTMENT
18.00'10.00'CONCRETE FOOTING (BELOW)
CAST-IN-PLACE CONCRETE
CORE WALL
ALUMINUM DOUBLE
SWING GATE
(2) 6'-0" WIDE GATE PANELS
12.00'
6.00'6.00'
1.00'
STONE VENEER
(LIMESTONE VENEER TO
MATCH BUILDING)1.00'TYP.20.50'6.00'3.50'1.00'1.00'
TYP.3"3"
CONCRETE FOOTING (BELOW)
PRECAST CONCRETE CAP
STONE VENEER
12.50'
20.50'6.00'3.50'1.00'1.00'
TYP.3"CONCRETE FOOTING (BELOW)
PADLOCKABLE SLIDE BOLT
12.00'
6.00'6.00'
HEAVY DUTY BARREL HINGES
(2) PER GATE PANEL
2" SQ. ALUMINUM TUBE FRAME
ALUMINUM INFILL PANEL
BASIS OF DESIGN IS AMETCO
ALUMINUM VENETIAN
DOUBLE SWING GATE
12" x 1/4" ALUMINUM PLATE
(PAINTED BLACK), STUD
MOUNTED 1" OFF WALL FACEWEST PARK
THE GROVES
3030 W. 116TH STREET
6" x 1/4" ALUMINUM PLATE
(PAINTED BLACK), STUD
MOUNTED 1" OFF WALL FACE
WEST PARK
THE GROVES
3030 W. 116TH STREET
SOUTH ELEVATION EAST ELEVATION (NO SIGNAGE ON WEST ELEVATION)
NORTH ELEVATION
NOTES:
1. BASIS OF DESIGN FOR DOUBLE SWING
GATE IS AMETCO ALUMINUM DOUBLE
SWING GATE WITH VENETIAN INFILL
PANELS. COLOR TO BE SELECTED BY
OWNER FROM MANUFACTURER'S
STANDARD COLORS, OR APPROVED
EQUAL.
2. STONE VENEER TO MATCH SIZE,
COLOR AND TEXTURE OF LIMESTONE
VENEER ON BUILDING.
STAINLESS STEEL DOWEL, 3/8" X 4",
EPOXY SET. 2 PER CAPSTONE
PRECAST CAP WITH
CONTINUOUS 1/2" x 1/2" DRIP EDGE.
SLOPE TOP OF CAP TO DRAIN
LIMESTONE VENEER,
·1-1/4" THIN VENEER, ADHERED
·MATCH COLOR, SIZE AND
PATTERN OF BUILDING
LIMESTONE VENEER
12" MORTAR SETTING BED
VENEER LEDGE, SLOPE TO DRAIN
NOTE:
1. PROVIDE ENGINEERED DETAILED
SHOP DRAWINGS INCLUDING ALL
STRUCTURAL MATERIAL
DIMENSIONS, CONNECTIONS,
HARDWARE AND FOOTING DETAILS.
REINFORCED CAST-IN-PLACE
CONCRETE WALL
REINFORCED CAST-IN-PLACE
CONCRETE FOOTING
FINISHED GRADE
SEE GRADING PLANS
HEAVY DUTY CONCRETE PAVING
(INSIDE TRASH ENCLOSURE)6'-0"3"1'-0"3'-6"3'-11
2", MIN.
1'-0", TYP.
KEYED CONSTRUCTION JOINT2"#5 BENT BAR DOWEL TO FOOTING
(30" HIGH, 12" LEG), 12" O.C., SPLICED
WITH VERTICAL REINFORCEMENT
EACH FACE.
EXPANSION JOINT, CONTINUOUS
#5 @ 12" O.C.
#5 CONTINUOUS
#5 REBAR @ 12" O.C. TOP AND
BOTTOM
3" CLR.2"
CLR.3" CLR.PREPARED SUBGRADE
3"
1'-0"
1'-8"
Site Details
C509
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
NOT TO SCALE
DRINKING FOUNTAIN1 SCALE: 1/2" = 1'-0"
METAL GRATE WALKWAY2 SCALE: 1" = 5'-0"
TRASH ENCLOSURE - PLAN3
SCALE: 1" = 5'-0"
TRASH ENCLOSURE - ELEVATIONS4 SCALE: 3/4" = 1'-0"
TRASH ENCLOSURE - SECTION5
VARIES4"MIN.MAX = O.D. + 24"
BEDDING AND INITIAL BACKFILL:VARIES4"MIN.MAX = O.D. + 24"
O.D.1'1/2 O.D.1/2 O.D.O.D.
SATISFACTORY SOILS
BEDDING
NON-RIGID PIPE
(INCLUDING PVC, HDPE)
RIGID PIPE
(INCLUDING RCP)
FINAL
BACKFILL
INITIAL
BACKFILL
HAUNCHING
BEDDING
COMPACTED BACKFILL OR
PAVEMENT STRUCTURE
COMPACTED BACKFILL OR
PAVEMENT STRUCTURE
Utility Details
C510
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
NOT TO SCALE
GRINDER PUMP STATION1
NOT TO SCALE
FIRE HYDRANT ASSEMBLY4 NOT TO SCALE
WATER MAIN THRUST RESTRAINT6
NOT TO SCALE
PIPE BEDDING (RCP, PVC, HDPE)3
NOT TO SCALE
CONNECTION TO EXISTING WATER MAIN5
NOT TO SCALE
TRENCH DETAIL FOR SEWERS AND WATER MAINS2
NOTES
1) GRINDER PUMP TO BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
2) BASIN DISCHARGE PIPE MATERIAL TO BE 2" HDPE, DR 11.
Factory Applied Red Paint
ADJUST TO FINISH
GRADE WITH
CONCRETE GRADE
RINGS
FINISHED GRADE
PRECAST CONCRETE
CL
6" MIN.
COMPACTED
AGGREGATE
BASE
6"
3'-8"
PRECAST OR
CAST IN PLACE
CONC. BASE
2'-0"
6" MIN
12" MAX
OUTLET PIPE
SEE PLAN FOR SIZE AND
INVERT ELEVATION
WATERTIGHT FLEXIBLE
BOOTS MUST BE USED AT ALL
OPENINGS
SEE UTILITY PLANS FOR
FRAME AND GRATE TYPE
2.0' SUMP
NOTE: INSTALL TEMPORARY INLET
PROTECTION FILTERS IN ALL PROPOSED
CATCH BASINS, UNTIL VEGETATION IS
ESTABLISHED. SEE DETAIL #8, SHEET C501.DIAMETERFLARED END SECTION
SLOPE AS PER PLANS
FLARED END SECTION
PLACE STONES ON SIDE
SLOPE OF OUTLET
RIPRAP ON SIDE SLOPES
PLAN
STONES TO BE NATURAL FIELDSTONE, GRADATION SAME AS INDOT
REVETMENT RIPRAP, CLASS 1. PLACE LARGER STONES NEAR
OUTLET TO DISSIPATE OUTLET WATER ENERGY.
CONSTRUCT 6" DEEP SWALE IN SUBGRADE
ALONG RIP-RAP CENTERLINE
GEOTEXTILE FILTER
FABRIC UNDER ALL STONE
1'5'-0" LENGTH 4' PLUS CULVERTSECTION
6"6"6"2'-0"6"
2
C503CONCRETE PAVING
AGGREGATE
BASE
CONCRETE WEDGE
ANCHORS @ 18" O.C., TYP.
STEEL FRAME, TYP.
POWDER COAT FINISH
URBAN ACCESSORIES - JAMISON
TRENCH DRAIN: 24" WIDTH
FINISH GRADE VARIES,
SEE GRADING PLAN
FOR RIM ELEVATIONS
NOTES:
1. RIM & ELEVATIONS VARY, SEE UTILITY PLAN
GRANULAR
BACKFILL
CAST-IN-PLACE
CONCRETE VARIES,SEE PLAN10'-0"FINISH GRADE
TRENCH GRATE TURNDOWN
FLOW-THROUGH TRENCH GRATE
URBAN ACCESSORIES - JAMISON
TRENCH DRAIN: 24" WIDTH
CAST-IN-PLACE CONCRETE
TRENCH DRAIN
CURB OPENINGS WHERE
INDICATED ON PLAN,
NEENAH MODEL R-3262-3
FINISH GRADE
TOPSOIL
COMPACTED
SUBGRADE
AGGREGATE BASE
2' DIA
4' DIA
SEE PLANS FOR LID TYPE
AND RIM ELEVATION
4'-0" SUMP5" (TYP)5" (TYP.)
OUTLET PIPE
SEE PLANS FOR SIZE & INVERT
INLET PIPE
SEE PLANS FOR SIZE & INVERT
4' DIA
2' DIA
MANHOLE STEPS
TOP STEP TO BE 1'-6"
BELOW CASTING
6.0"Ø ORIFICE PLATE
SEE PLANS FOR INVERT
6.0"Ø ORIFICE PLATE
SEE PLANS FOR INVERT
SEE PLANS FOR LID TYPE
AND RIM ELEVATION
WATERTIGHT FLEXIBLE BOOTS MUST
BE USED AT ALL OPENINGS
CONCRETE ADJUSTING RINGS
LIMITED TO (3) RINGS. MAXIMUM
COMBINED HEIGHT OF 12". RINGS
MUST BE BUTYL RUBBER COATED
WITH PLASTIC WRAP COVER.
BED BASE SECTION IN MIN. 6"
COMPACTED #8 GRANULAR MATERIAL
APPLY MINIMUM 10 MIL
BITUMINOUS COATING TO
EXTERIOR OF STRUCTURE
Utility Details
C511
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
NOT TO SCALE
STORMWATER CATCH BASIN, 2' DIAMETER1 NOT TO SCALE
STORM SEWER FLARED END SECTION AND RIPRAP4NOT TO SCALE
STORMWATER MANHOLE, 4' DIAMETER2
NOT TO SCALE
TRENCH DRAIN5
STEEL TRENCH GRATE
URBAN ACCESSORIES - JAMISON
TRENCH DRAIN: 24" WIDTH
TRENCH DRAIN ASSEMBLY, SECTION VIEW
TRENCH DRAIN ASSEMBLY, PROFILE VIEW
NOT TO SCALE
STORMWATER RESTRICTING STRUCTURE (STM-RESTRICTOR-01, STM-RESTRICTOR-02)6
NOT TO SCALE
TRENCH DETAIL FOR CITY STORM SEWERS3
NOTES:
1)SPLICE KIT (KING INNOVATION DRYCONN, DIRECT BURY LUG AQUA, CATALOG #90220) AT ALL TRACER
WIRE SPLICING LOCATIONS
2)TRACE WIRE SHALL BE #8 AWG COPPER CLAD STEEL EXTRA HIGH STRENGTH, PART NUMBER
845*EHS, WITH A BREAK LOAD OF 2,785 POUNDS. WIRE SHALL BE COATED WITH A MINIMUM 30 MIL
HDPE COATING. MINIMUM OF THREE (3) TRACE WIRES SHALL BE INSTALLED ALONG PIPE INSTALLED
FOR ALL DIRECTIONAL DRILLING/BORING.
3)USE OF NON-LOCKING FRICTION FIT, TWIST ON OR TAPED CONNECTORS ARE PROHIBITED.
CONNECTORS SHALL BE DIRECT BURY WIRE CONNECTORS, DRYCONN 3-WAY DIRECT BURY LUG,
COPPERHEAD PART NUMBER 3WB-01, OR EQUIVALENT TO BE APPROVED BY THE ENGINEER.
CONNECTORS SHALL BE DIELECTRIC SILICON FILLED TO SEAL OUT MOISTURE AND CORROSION, AND
SHALL BE INSTALLED IN A MANNER SO AS TO PREVENT ANY UNINSULATED WIRE EXPOSURE.
4)ALL TRACE WIRE TERMINATION POINTS MUST UTILIZE AN APPROVED TRACE WIRE ACCESS BOX
(ABOVE GROUND OR GRADE LEVEL/IN-GROUND AS APPLICABLE), SPECIFICALLY MANUFACTURED
FOR THIS PURPOSE. ALL GRADE LEVEL/IN-GROUND ACCESS BOXES SHALL BE APPROPRIATELY
IDENTIFIED WITH “SEWER” CAST INTO THE CAP AND BE COLOR CODED. A MINIMUM OF 2 FT. OF
EXCESS WIRE IS REQUIRED IN ALL GRADE LEVEL TRACE WIRE ACCESS BOXES AFTER SETTING AT
FINAL GRADE.
2" HDPE DR 11 SEWER PIPE
DRILL INTO PVC TO ACCEPT
TRACER WIRE FROM OUTSIDE
10 GAUGE TRACER WIRE,
DOUBLE PULL (TYP.)*
6" PVC (TO BE CUT TO LENGTH
AND NOTCH PVC AT THE
BOTTOM TO FIT OVER MAIN.)6" MAX.COVER/LID SIGMA CORPORATION VB-284 (VB-2841S)
MATERIAL: CAST IRON ASTM A4B CLASS-25B
ENGINEERED WOOD PLAY SURFACING
FINISH GRADE
6" DOUBLE WALL PIPE, PERFORATED
HANCOR Hi-Q, TYPE 4 PIPE OR
EQUIVALENT PER SECTION 401.01 OF
THE CITY OF CARMEL STORMWATER
TECHNICAL STANDARDS. SLOPE TO
DRAIN
NON-WOVEN FILTER FABRIC, 12" MIN. LAP
AT SUBGRADE LEVEL
#8 WASHED AGGREGATE
14"
EQ.EQ.2"8" MIN.18" MIN.2" MIN.Utility Details
C512
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
NOT TO SCALE
SANITARY CLEANOUTS2 NOT TO SCALE
FORCE MAIN TO MANHOLE CONNECTION3
NOT TO SCALE
TRACER STATION, TRACE WIRE AND FORCE SEWER DETAIL4
NOT TO SCALE
DEBRIS GUARD FOR FLARED END SECTIONS1
NOT TO SCALE
UNDERDRAIN, TYPICAL5 NOT TO SCALE
STORM STRUCTURE SIZING TABLE7NOT TO SCALE
UNDERDRAIN BENEATH WOOD PLAY SURFACING6
8
C503
1
1 STORMWATER PERMIT RESUBMIT 05/04/18
Landscape Schedule
C513
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
PLANT SCHEDULE UPLAND SEED MIX WET/MESIC SEED MIX WOODLAND SEED MIX
Landscape Details
0'40'20'10'
SCALE:
C514
SEALS AND SIGNATURES
KEY PLAN
DRAWING TITLE
PROJECT NUMBER
SCALE
DRAWING NUMBER
DATEREVISSUED FOR
22109
WEST PARK:
THE GROVES
3030 W. 116TH STREET
CARMEL, IN 46032
Owner:
44 EAST MIFFLIN STREET
SUITE 500
MADISON, WI 53703
608.251.1177
www.smithgroupjjr.com
500 PARK BOULEVARD
SUITE 800
ITASCA, IL 60143
630.221.1212
www.williams-architects.com
DESIGN DEVELOPMENT 08/25/17
N
75% CD 11/27/17
STORMWATER PERMIT SET 12/12/17
ISSUED FOR BID 01/11/18
ISSUED FOR RE-BID 02/22/18
STORMWATER PERMIT RESUBMIT 03/06/18
ISSUED FOR CONSTRUCTION 04/02/18
SCALE: 1" = 1'
DECIDUOUS TREE PLANTING1 SCALE: 1" = 1'
EVERGREEN TREE PLANTING2 SCALE: 1" = 1'
ORNAMENTAL TREE PLANTING3
SCALE: 1" = 1'
SHRUB PLANTING4 SCALE: 1" = 1'
PERENNIALS/GRASS PLANTING5 SCALE: 1" = 1'
PLANT SPACING6
PLANTING MIXTURE AS
SPECIFIED
MOUND TOPSOIL TO
FORM SAUCER
TREE WRAP
UNDISTURBED GROUND
18" MIN.
NOTES:
PRIOR TO DIGGING EACH PLANTING HOLE, REMOVE
SOIL FROM THE TOP OF THE ROOTBALL AND EXPOSE
ROOT COLLAR. DIG HOLE NO DEEPER THAN
DISTANCE FROM ROOT COLLAR TO BOTTOM OF
ROOTBALL. TREES PLANTED WITH ROOT COLLAR
NOT VISIBLE AND/OR BELOW GRADE WILL BE
REJECTED.
ONCE TREE IS POSITIONED IN HOLE
AND BACKFILLING HAS BEGUN, CUT
OFF AND COMPLETELY REMOVE FROM
HOLE ALL BURLAP AND WIRE BASKET
FROM AT LEAST TOP 12 OF BALL
APPLY MULCH 3" DEEP,
KEEP MULCH 5" AWAY
FROM TRUNK
ROOT COLLAR TO BE SET SLIGHTLY
ABOVE FINISH GRADE
SCARIFY SIDES AND BOTTOM
OF HOLE, AT LEAST 4"
'X' DIA
2X-3X DIA
UNDISTURBED
GROUND
MOUND TOPSOIL TO
FORM SAUCER
TREE ANCHOR
18" MIN.
PLANTING MIXTURE, AS
SPECIFIED
PRIOR TO DIGGING EACH PLANTING HOLE, REMOVE
SOIL FROM THE TOP OF THE ROOTBALL AND EXPOSE
ROOT COLLAR. DIG HOLE NO DEEPER THAN
DISTANCE FROM ROOT COLLAR TO BOTTOM OF
ROOTBALL. TREES PLANTED WITH ROOT COLLAR
NOT VISIBLE AND/OR BELOW GRADE WILL BE
REJECTED.
ONCE TREE IS POSITIONED
IN HOLE AND BACKFILLING
HAS BEGUN, CUT OFF AND
COMPLETELY REMOVE
FROM HOLE ALL BURLAP
AND WIRE BASKET FROM
AT LEAST TOP 12 OF BALL
APPLY MULCH 3" DEEP,
KEEP MULCH 5" AWAY
FROM TRUNK
SCARIFY SIDES AND BOTTOM
OF HOLE, AT LEAST 4"
NOTES:
'X' DIA
2X-3X DIA
PLANTING MIXTURE AS
SPECIFIED
TOPSOIL FILL OR
UNDISTURBED SOIL
TREE WRAP
MOUND TO FORM SAUCER 18" MIN.
PRIOR TO DIGGING EACH PLANTING HOLE, REMOVE
SOIL FROM THE TOP OF THE ROOTBALL AND EXPOSE
ROOT COLLAR. DIG HOLE NO DEEPER THAN
DISTANCE FROM ROOT COLLAR TO BOTTOM OF
ROOTBALL. TREES PLANTED WITH ROOT COLLAR
NOT VISIBLE AND/OR BELOW GRADE WILL BE
REJECTED.
ONCE TREE IS POSITIONED IN
HOLE AND BACKFILLING HAS
BEGUN, CUT OFF AND COMPLETELY
REMOVE FROM HOLE ALL BURLAP
AND WIRE BASKET FROM AT LEAST
TOP 12 OF BALL
APPLY MULCH 3" DEEP,
KEEP MULCH 5" AWAY
FROM TRUNK
SCARIFY SIDES AND BOTTOM
OF HOLE, AT LEAST 4"
NOTES:
NEVER CUT LEADERS. PRUNE TO THIN AND SHAPE
TREE CANOPY. SEE DETAIL. TREE SHALL BEAR SAME
RELATION TO FINISHED GRADE AS IT BORE TO
PREVIOUS GRADE.
'X' DIA
2X-3X DIA
MIN. 6"
NOTES:
PRUNE AS SPECIFIED
REMOVE BURLAP FROM TOP 1/2 OF BALL, OR,
WITH CONTAINER PLANTS, REMOVE POTS
AND SPLIT BALLS AS SPECIFIED.
PLANTING MIXTURE AS
SPECIFIED, BED TO BE 2X
DIA OF BALLED
ROOTBALL
SCARIFY TO 4" DEPTH AND
RECOMPACT
BALLED AND BURLAPPED
SHRUBS
BARE ROOT OR CONTAINER
SHRUBS
SUBGRADE
3" OF MULCH, KEEP MULCH 3" AWAY
FROM BASE OF BRANCHES
SET ROOT COLLAR AT
FINISHED GRADE
ROOTBALL24"PLANTING MIXTURE AS
SPECIFIED
1" FINELY SHREDDED
COMPOSTED BARK
VARIES
FINISH GRADE
SPADE CUT BED
EDGE
TOPSOIL
PERENNIAL, TYP.
PLUG, TYP.
D=DIMENSION OF PLANT SPACING (SHRUB, GROUNDCOVER OR
PERENNIAL) IN BED PLANTINGS
"D""D"
"D"
GROWING MEDIUM SOIL
(TOPSOIL FURNISH AND PLACE)
SEE PLAN FOR
LOCATION
SUBGRADE 1'-0"NOTES:
1.GROWING MEDIUM SOIL MUST BE A
MIX OF 40% SAND, 30% TOPSOIL AND
30% COMPOST.
2.DRAIN AGGREGATE SHALL GRADED
WITH A D50 SIZED BETWEEN 1.5 AND 3
INCHES, AND CLAY CONTENT OF TO
LESS THAN 30 PERCENT. THE
POROSITY OF THE MATERIAL SHOULD
BE BETWEEN 0.3 AND 0.4.
PROPOSED TOPSOIL
2'-0"DRAIN AGGREGRATE
FILTER FABRIC
SCALE: 1/2" = 1'
VEGETATED FILTER STRIP WITH INFILTRATION TRENCH7 SCALE: NOT TO SCALE
NATIVE SEEDING LIMITS SIGN8 5'-0" MIN. MOUNTING HEIGHT4" X 4" WOOD POST
3'-0"DIRECT BURY POST
NOTE:
1.ALL CONNECTIONS
SHALL BE ALUMINUM &
VANDAL-PROOF.
2.REGULATORY SIGNS
SHALL CONFORM TO
ALL FEDERAL, STATE
AND LOCAL STANDARDS.
3.SUBMIT SHOP
DRAWINGS.
"NATIVE WILDFLOWER
PLANTING" SIGNAGE.
INSTALL AT 150'-0" O.C.
AROUND THE PERIMETER
OF PEDESTRIAN AREAS
WHERE ADJACENT TO
NATIVE SEEDING.
FINISHED GRADE
SIGNAGE ENLARGEMENT
9"12"1
1 STORMWATER PERMIT RESUBMIT 05/04/18