Loading...
HomeMy WebLinkAboutC301 Site PlanE E E E E E E E E E EEEEEEEW(F)W(F)W(F)W(F)W(F)W(F )W(F )W(F)W(F )W(F )W(F)W(F )W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)W(F)EEEEEEEEEEEE36,833± S.F.FFE=901.00MLAG/PAD=900.33BUILDING #236,833± S.F.FFE=901.50MLAG/PAD=900.83BUILDING #336,833± S.F.FFE=901.00MLAG/PAD=900.33BUILDING #236,833± S.F.FFE=901.50MLAG/PAD=900.83BUILDING #3FFE=899.46FFE=899.33FFE=899.00FFE=899.46PONDW(F) W(F) W(F) W( F )W(F)W(F)W(F)W(F)PONDPONDLOT 314.56 ACDOLCE DRIVEVERDI DRIVEOPUS DRIVE W(F) W(F) W(F) E EEEEEEEE EEEEW(F)W(F)W(F)STMSTMSTMSTMSTMSTMSTM STMSTMSTM STMSTMSTMSTM STMSTMSTMSTMSTM STM STM STMH4H4H4H4H4H4H4H4H4H4H4H4H1H1H1H1H7H1H1H1H1H1H1H1H1H1H1H1H1H1H1H1H1H1S2S2H5H3H5H3H3H3H3H3S3S3S3S3S3S3S3S3S3S3S3S3S3S3S3S3S3P2P2P2P2P2P2P2S2S2H3H7H1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1P1H1P1P1P1P1P1H3H1H1H1H1H7H7H8H8ESANW(F)WENGINEERS 317 | 846 - 6611 800 | 452 - 6408 317 | 843 - 0546 fax WEIHE Land Surveying | Civil Engineering Landscape Architecture ALLAN H. WEIHE, P.E., L.S. - FOUNDER 10505 N. College Avenue Indianapolis, Indiana 46280 weihe.netARIA APARTMENTS APPRO V A L P E N D I N G N O T F O R C O N S T R U C T I O NKnow what'sbelow.before you dig.CallRWSNE779 LENNOX COURTC301SITE PLAN PROJECT BENCHMARKDNR BM BOO 54, 1989IN BOONE COUNTY, CARMEL QUAD., IN THE NE ¼ OF SEC. 36,T. 18 N., R. 2 E., 2ND P.M.; ABOUT 1.0 MILE NORTHEAST OFZIONSVILLE; AT THE INTERSECTION OF DAUGHERTY DRIVEAND WEST 121ST STREET, IN THE NORTHEAST ¼ OF THEINTERSECTION, AT THE ENTRANCE TO THE EAGLE VILLAGESUBDIVISION; SET IN THE TOP OF A CONCRETE POST, 42.3FEET NORTHEAST OF AND ACROSS WEST 121ST STREETFROM A UTILITY POLE, 25.8 FEET NORTH OF THE CENTERLINEOF WEST 121ST STREET, 20.5 FEET WEST-NORTHWEST OF AMETAL TELEPHONE PEDESTAL, 20.2 FEET SOUTHWEST OF AWOOD FENCE END POST, 18.5 FEET EAST OF THE CENTERLINEOF DAUGHERTY DRIVE, 15.7 FEET NORTHWEST OF THE TOPOF THE CENTER OF A CMP CULVERT UNDER DAUGHERTYDRIVE, 15.4 FEET WEST OF THE SOUTHEAST CORNER OF ABRICK WALL, 10.1 FEET SOUTHWEST OF THE NORTHWESTCORNER OF A BRICK WALL, 5.8 FEET SOUTHWEST OF A METAL“DAUGHERTY DR” SIGN POST, LEVEL WITH THE GROUND; ADEPARTMENT OF NATURAL RESOURCES BRASS CONTROLSTATION TABLET, STAMPED "BOO 54 1989".ELEV.900.76 NAVD 88SITE TEMPORARY BENCHMARK1. CUT X ON THE NORTH BOLT OF A FIRE HYDRANT LOCATED47 FEET EAST OF THE NORTHWEST CORNER OF PARCEL I.ELEV.901.82 NAVD 882. RAILROAD SPIKE ON THE NORTH SIDE OF A UTILITY POLELOCATED ON THE EAST SIDE OF MICHIGAN ROAD 115 FEETNORTH AND 93 FEET EAST OF THE SOUTHEAST CORNEROF PARCEL I.ELEV.901.81 NAVD 88GENERAL NOTES1.THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING, OR VERIFYING THAT ALL PERMITS ANDAPPROVALS ARE OBTAINED FROM THE RESPECTIVE CITY, COUNTY, AND STATE AGENCIES PRIOR TOSTARTING CONSTRUCTION.2.ALL QUANTITIES GIVEN ON THESE PRINTS, VERBALLY OR IN THE SCOPE OF WORK SECTION ARE ESTIMATESAND SHALL BE CONFIRMED BY THE BIDDING CONTRACTORS.3.OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) STANDARDS FOR EXCAVATIONS; FINAL RULE29 CFR PART 1926, SUBPART "P" APPLIES TO ALL EXCAVATIONS EXCEEDING FIVE (5) FEET IN DEPTH. INADDITION, EXCAVATION EXCEEDING TWENTY (20) FEET IN DEPTH REQUIRE THE DESIGN OF A TRENCH SAFETYSYSTEM BY A REGISTERED PROFESSIONAL ENGINEER.4.IT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER AND CONTRACTOR TO MAINTAIN QUALITY CONTROLTHROUGHOUT THIS PROJECT.5.TEMPORARY TRAFFIC CONTROL DURING CONSTRUCTION TO CONFORM TO APPLICABLE LOCAL STANDARDS.6.BEARINGS, DIMENSIONS, AND EASEMENTS ARE SHOWN FOR REFERENCE ONLY. SEE RECORD SURVEYS ANDPLATS FOR EXACT INFORMATION.7.THE ENGINEER AND/OR OWNER DISCLAIM ANY ROLE IN THE CONSTRUCTION MEANS AND METHODSASSOCIATED WITH THE PROJECT.8.ALL DIMENSIONS ARE BASED ON FACE OF CURB OR BACK OF ROLL CURB OR FACE OF BUILDING.9.SEE ARCHITECTURAL PLANS FOR DETAILS OF BUILDING, BUILDING DIMENSIONS AND SIGNAGESPECIFICATIONS. DO NOT STAKE BUILDING FROM THESE PLANS.10.COORDINATE CONSTRUCTION ACTIVITIES WITH ADJOINING WORK IF APPLICABLE. VERIFY EXTENT OFADJOINING WORK AND COORDINATE AS REQUIRED.11.FIELD VERIFY EXISTING CURBS AND TAPER PROPOSED VERTICAL CURBS TO MATCH WITHIN A MIN. OF THREE(3) FEET.12.± DIMENSIONS INDICATE FIELD DIMENSION ADJUSTMENT AREA BASED ON ACTUAL FIELD LAYOUTCOORDINATES.13.THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO START OF CONSTRUCTION. THECONTRACTOR SHALL BE RESPONSIBLE FOR ALL FIELD DIMENSIONS. IF ANY DISCREPANCIES ARE FOUND INTHESE PLANS FROM ACTUAL FIELD CONDITIONS, THE CONTRACTOR SHALL NOTIFY THE ENGINEERIMMEDIATELY.14.PROVIDE SMOOTH TRANSITION FROM NEWLY PAVED AREAS TO EXISTING AREAS AS NECESSARY. ALL AREASWHERE PROPOSED PAVEMENT MEETS EXISTING PAVEMENT, THE EXISTING EDGE OF PAVEMENT SHALL BEFREE OF ALL LOOSE DEBRIS. THE EDGE OF EXISTING ASPHALT PAVEMENT SHALL BE PROPERLY SEALED WITHA TACK COAT MATERIAL IN ALL AREAS WHERE NEW ASPHALT PAVEMENT IS INDICATED TO JOIN EXISTING.15.RESURFACE OR RECONSTRUCT AT LEAST TO ORIGINAL CONDITIONS ALL AREAS WHERE THE EXISTINGPAVEMENT OR LAWNS ARE DAMAGED DURING CONSTRUCTION FROM TRAFFIC BY CONTRACTORS,SUBCONTRACTORS, OR SUPPLIERS AFTER CONSTRUCTION WORK IS COMPLETE.16.THE CONTRACTOR SHALL PROTECT AND NOT DESTROY THE PROPERTY CORNER MONUMENTS DURINGCONSTRUCTION.17.REFER TO ARCHITECTURAL PLANS FOR BUILDING ACCESSORY DETAILS.18.REFER TO SHEET C201 FOR SITE PLAN DETAILS UNLESS OTHERWISE NOTED.LEGEND:SITE PLAN NOTESPAVEMENTSTANDARD DUTY ASPHALT PAVINGHEAVY DUTY ASPHALT PAVINGMATCH EXISTING PAVEMENTCARMEL ASPHALT PAVINGINDOT ASPHALT PAVINGCONCRETE PAVEMENTHARDSCAPE6" STRAIGHT CURBMATCH EXISTING CURBCONCRETE SIDEWALKADA RAMPCONCRETE SIDEWALK AND CURBEDGE OF ASPHALT PAVEMENTCONCRETE SIDEWALK, CURB FLUSH WITHASPHALT PAVEMENTELECTRIC TRANSFORMER PAD PER DUKE REQ.SIGNAGE & MARKINGSADA PARKING & SIGNSPEDESTRIAN CROSSWALK4" PAINTED WHITE SOLID LINES (TYP)4" PAINTED YELLOW SOLID LINES (TYP)H1H2H3H4P1P2P3S1S2S3S4P4P5P6H5H7H8H6