HomeMy WebLinkAboutC606 Storm DetailsENGINEERS 317 | 846 - 6611 800 | 452 - 6408 317 | 843 - 0546 fax WEIHE Land Surveying | Civil Engineering Landscape Architecture ALLAN H. WEIHE, P.E., L.S. - FOUNDER 10505 N. College Avenue Indianapolis, Indiana 46280 weihe.netARIA APARTMENTS APPRO V A L P E N D I N G N O T F O R C O N S T R U C T I O N 779 LENNOX COURTC606STORM SEWER DETAILSDOUBLE INLET TYPE "A" MODIFIEDVARIES (4.0' MAX.)6" (TYP.)24"x24"T.C. ELEVATION24"x24"12" (TYP.)NOTE: THE SIZEOF THE INTERNALPIPE IS THE SAMEAS THE SIZE OFTHE OUTLET PIPE.OUTLET PIPE6" (TYP.)1. STRAIGHT-OUT CONNECTIONS SHOULD NOT BE MADE TOEITHER PRECAST BOX OR INLET WALL TOUCHED BY ASKEW/CORNER CONNECTION UNLESS SUFFICIENT BOX INLETWALL AREA REMAINS ON EACH SIDE OF THE CONNECTINGPIPE TO ENSURE STRUCTURAL INTEGRITY OF THE PRECASTBOX.2. A MAXIMUM OF 2 SKEW/CORNER CONNECTIONS WILL BEALLOWED FOR EACH PRECAST BOX INLET.3. REFER TO PRECAST CONCRETE ADJUSTING RING DETAIL ASREQUIREDPAVEMENTNOTES:1. 6" CONCRETE PRECAST OR POURED INPLACE.2. REFER TO BEDDING DETAIL ASREQUIRED3. VAR. PIPE SIZE 18" MAX STRAIGHT CONNECTIONS 15" MAX SKEW/CORNER CONNECTIONSVARIES 16" MIN. 8"CASTING TYPE AS NOTED ONPLAN & PROFILECLASS "A" CONCRETEINLET SET ON 6" BASE OF#8 STONE OR #2 STONE(NO SCALE)PIPE SIZES 12" TO 18"SPILLWAY DETAILNOT TO SCALESECTION A-ASECTION B-BAABBPOND - OUTLET STRUCTURE #64NOT TO SCALE