Loading...
HomeMy WebLinkAboutUS 421 Drive Permit 4End Taper 6+92.17 38.00' Lt. Begin Taper 6+35.17 25.65' Lt.6+007+008+009+0010+0011+006+62.38 40.27' Lt. Begin Project Sta. 6+35.11 "PR-A1"= Sta. 404+68.66 "A" 8.08' Lt. Sec. 6, T-17-N, R-3-E Clay Twp. Hamilton County Sec. 6, T-17-N, R-3-E Clay Twp. Hamilton County +94.18, Str. No. 12 Inlet Type J-10 & 18' of 12" Pipe Type 2 Req'd. Rim El.= +/-901.06 Inv.= 897.65 Attach to Manhole at Inv.= 897.47 +24.61, Str. No. 13 Inlet Type J-10 & 13' of 12" Pipe Type 2 Req'd. Rim El.= +/-900.61 Inv.= 897.56 Attach to Existing Pipe +04.32, Str. No. 16 Inlet Type J-10 & 13' of 12" Pipe Type 2 Req'd. Rim El.= +/-900.02 Inv.= 896.16 Attach to Existing Pipe NOTTINGHAM, LLC JDF MICHIGAN ROAD LLC LEGEND 14 A 26 C F PCCP for Approaches, 9 in. on Subgrade Treatment, Type II Sidewalk: 4" PCCP on 4" Compacted Aggregate, No. 53, Base Full Depth Concrete Pavement: QC/QA-PCCP, 13" with D-1 Contraction Joints at 18' Spacing on Subbase for PCCP: 3" Coarse Aggregate, No. 8 on 6" Compacted Aggregate, No. 53 on Subgrade Treatment, Type IC Integral Concrete Curb Sodding, Nursery X Curb Ramp P PCCP Patching, Full Depth on Flowable Fill C A AA AA 1414 14 F F F +72.80, Str. No. 10 Existing Inlet Remove Inlet & Pipe +72.90, Str. No. 11 Existing Manhole Plug opening for pipe removed to the West. +24.61, Str. No. 14 Existing Inlet Remove Structure +24.61, Str. No. 15 Existing Manhole No Change Req'd +04.32, Str. No. 17 Existing Inlet Remove Structure +04.32, Str. No. 18 Existing Manhole No Change Req'd405+20, 0.0', Brass Plug405+20, 68.9', R/W405+55, 0.35', Drillhole405+65, 38.17', Telephone Manhole405+96, 33.70', Curb Inlet405+96, 24.62', Manhole406+61, 63.13, Weihe Rebar Found406+64, 54.05', Telephone Pedestal406+82, 59.06', R/W406+82, 68.31', Manhole407+48, 33.84', Curb Inlet407+48, 24.75', Manhole408+74, 73.85', Sign408+75, 88.09', Sign409+28, 25.10', Manhole409+28, 33.72', Curb InletApp. P.L.App. P.L.App. Exist. R/W App. Exist. R/WApp. Exist. R/W Line "PR-A1" Line "A" N15°22'05.25"WN15°22'05.25"W N15°21'03.92"W US 421 US 421 Weston Pointe DriveA C Esmt. P P7+42.18, Cl. III Dr.W=40', L=35'Control Point 102 406+40.05, "A" 48.10' Lt. Control Point 105 405+20.59, "A" 0.00' t. P +93.14, Str. No. 12A Manhole Type C-4 Req'd. Attach to Existing Pipe Inv.= 894.54 +/- P8.0014.0024.001.6524.008.08PT = 405+20.59 "A" CURVE DATA From Contract No. R-26096 (metric) PI = 12+129.089 "A" Delta = 4°48'37" R = 5282.3896 m T = 221.8723 m L = 443.4840 m E = 4.6575 m SE = NC PC = 11+907.2157 "A" Const. Limits Const. Limits Co n s t . L i m i t s Const. Lim i t s F X X 2626 F F5.005.008.0011.007.007.503.507.003.507.00R3 0 . 0 0 R30.007+22.68 73.16' Lt. Gutter Elev.= 900.57 7+61.68 73.09' Lt. Gutter Elev.= 900.57 7+42.18 73.09' Lt. Elev.=900.96 Begin Curb Taper 7+22.17 68.16' Lt. Begin Curb Taper 7+62.17 68.09' Lt.90.00°6.006.0071.4468.907.9959.0681.17'12.0012.0016.00TWLTL12.0012.0012.002.582.58Existing Stop Sign Proposed Signalized Intersection See Traffic Signal Installation Sheet 404+53.02 "A" 71.44' Lt. 405+20.59 "A" 68.90' Lt.406+82.33 "A" 59.06' Lt.26 2626 26 26 SURVEY BOOK VERTICAL SCALE HORIZONTAL SCALE CONTRACT PROJECT of DESIGNATION BRIDGE FILE SHEETSDRAWN: CHECKED: DESIGN ENGINEER DATE RECOMMENDED FOR APPROVAL DESIGNED: CHECKED: 1" = 20' 8365 Keystone Crossing, Suite 201, Indianapolis, IN. 46240 (317) 202-0864 N/A BGABGA JTR JTR 4 -- -- -- 18 N/A PLAN - LINE "PR-A1" STA. 5+00.00 TO STA. 11+00.00 Z:\2019\19009T - CITYSCAPE, US421-WESTON POINTE DR, CARMEL\DWG\19009T-PLAN.DWG Created By: BGA Date Created: 03/19/2019CITYSCAPE RESIDENTIAL4/17/2019