Loading...
HomeMy WebLinkAboutCross SectionIT IS THE RESPONSIBILITY OF THE HOMEOWNERS, CONTRACTOR OR PERSON OF AUTHORITY TO SEE THAT ALL INSPECTIONS ARE COMPLETED AS NECESSARY. FAILURE OF INSPECTIONS AS REQUIRED MAY REQUIRE APPROVAL OF A LICENSED ENGINEER OR ARCHITECT AND WOULD BE AT THE EXPENSE OF THE HOMEOWNERS, CONTRACTOR, OR PERSON OF AUTHORITY. NPI CONSULTING LLC AND ITS REPRESENTATIVES HAVE NO RESPONSIBILITY FOR PERMITTING, AND INSPECTIONS OF ANY KIND. FLOOR AND ROOF DESIGN LOADS FLOORS: 400 LIVE LOAD, 150 DEAD LOAD L/450 ROOFS: 300 LIVE LOAD, 150 DEAD LOAD SLEEPING ROOMS: 30* LIVE LOAD, 150 DEAD LOAD OTHER LOADS TO BE PER LOCAL AND STATE CODES 1 X 6 r tD it r-1>=C 1/2" TREATED PLYWOOD TO 5" NET :) 2 X 6 :I1" I RIPPED t0 SIZE FINISH GRADES AT BUILDING SHALL BE A MINIMUM OF 8" BELOW TOP OF FOUNDATION GRADE SHALL SLOPE I" PER FOOT FOR A DISTANCE OF 8' AWAY FROM BUILDING SOIL BEARING VALUE OF 1500 PSF FOOTINGS AND FOUNDATIONS ALL FOOTINGS SHALL BE A MINIMUM OF 30" BELOW FINISH GRADE. (SEE DRAWING) ALL FOUNDATIONS SHALL BE THICKNESS AS SHOWN ON DRAWINGS AND NOT LESS THAN 8", 2 X 6 SILL PLATES AROUND THE ENTIRE FOUNDATION, WITH WASHERS AND NUTS. SILL PLATES SHALL BE LEVEL OR GROUTED LEVEL. FOAM SILL SEALER BETWEEN FOUNDATION AND MUD SILL, 1/2" ROUND ANCHOR BOLTS, PLACED AT A MAXIMUM OF 4'-0" O.G. NO MORE THAN 12" FROM CORNER, AND MINN 8" INTO CONCRETE CROSS SECTION A SCALE: 1/4" = 1'-0" 6" X 6" TREATED POST+ SIMPSON PB/PBS POST BASE FOR 6 X 6 TREATED POST 24" ROUND TUBE (SONNE TUBE) TYPE FORM WITH BOTTOM OF TUBE 30" BELOW FINISHED GRADE FILLED WITH 2500 PSI OR BETTER CONCRETE CONCRETE: 1. 3000 PSI AT 28 DAYS BASEMENT WALLS AND FOUNDATION 3500 PSI AT 28 DAYS PORCHES, WALKS, PATIOS, STEPS GARAGE AND CARPORT FLOOR SLABS AND DRIVEWAYS 2. AIR ENTRANMENT 3-5% CONCRETE FOR ALL BASEMENT WALLS, FOUNDATION: WALLS, PORCHES, WALKS, PATIOS, STEPS, GARAGE AND CARPORT FLOOR SLABS AND DRIVEWAYS SHALL BE AIR -ENTRAINED, BASEMENT SLABS AND INTERIOR SLABS SHALL BE AIR -ENTRAINED IF THE CONCRETE IS PLACED AND SUBJECTED TO FREEZING AND THAWING ASPHALT SHINGLES 15# FELT PAPER 7/16" OSB SHEATING 2 X 12 RAFTERS 16" O.C. CLOSED SELL FOAM INSULATION MIN. R-3 1' BOXED OVERHANG HARDIE VERTICLE SIDING HOUSE WRAP 1/2" HIGH R BOARD INSULATION - 2 X 6-8 STUD WALLS, DOUBLE TOP PLATE SINGLE BOTTOM PLATE 3/4" OSB T @ G SUB FLOOR SHEATHING 11-7/8" RIM BOAR 11-7/8" 40 SERIES I JOIST-1 6" O.C. R-32 INSULATION 3/8 CEILING BOARD (PATTERN TBD) 6 X 6 COLUMN (SEE DETAIL) BRICK VENEER WITH LIMESTONE CAP (SEE DETAIL ON FOUNDATION FOR POSTS\ 4' CONCRETE FLOATING SLAB Retained material Grade must be at or below top of wall 2• dear Minimum 2 #4 rebar bond Drain rock to extend / beam at top of wall to +!- 12' of grade / Minimum 8" block, all cells grouted • o with minimum 2000 psi grout Minimum 12• of 4' max. 112• drain rock o Minimum #4 rebar Minimum 4" 16' o.C. each way perforated pipe sloped to daylight o u All splices lapped 20• minimum Grade 12 Minimum #4 rebar (di 12" o.c. min both ways•3' minimum clearance to earth or atmosphere gn 12" by 12'minimum kevwav vnth vertical rebar extending into keyway and minimum 1 #4 horizontal' rebar 12 12 6� 8° �6 E 0 1/2" DRYWALL ON CEILING AND WALLS R-18 INSULATION IN WALLS o n - o. I u a 0 n - o. 1 u a 0 n - o. 1 u a 0 DOUBLE 2"X4" TOP PLATE 2X4 BOTTOM PLATE TOP OF PLATE .90 TOP OF FINISHED FLOOR M I ti TOP OF FOUNDATION, O I TOP OF FOOTING A� Wsdnseday, July 31, 2024 N inM O O O a 3 z W z NJ W O M M .J 19 XLu V CO) N O m r W _II z T W LLI U U Z � 1. THE DESIGNER (NPI CONSULTING LLC) IS PROVIDING PLANS ONLY. NO OTHER TYPE OF SERVICE IS INTENDED OR IMPLIED. THESE PLANS ARE TO BE USED BY A COMPETENT LICENSED CONTRACTOR KNOWLEDGEABLE IN THE BUILDING TRADES, WHO WILL CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS AND BE RESPONSIBLE FOR THEM. 2. ADMINISTRATION OF THE JOB WILL BE BY OWNER OR HIS REPRESENTITIVE. THE CONTRACTOR AND THE OWNER SHALL BE SOLEY RESPONSIBLE FOR THE BUILDING CONSTRUCTION PROCESS MEANS AND METHODS AND JOBSITE SAFETY. 3. THE DRAWINGS INDICATE THE GENERAL SCOPE OF THE PROJECT. THE DIMENSIONS OF THE BUILDING, MAJOR ARCHITECTURAL ELEMENTS, AND TYPE OF STRUCTURAL SYSTEM. THE DRAWINGS DO NOT DESCRIBE ALL THE WORK REQUIRED FOR SUCCESSFULLY COMPLETING THE PROJECT. BASED ON THE DRAWINGS, THE CONTRACTOR MUST FURNISH ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THE WORK. 4. THE CONTRACTOR MUST THROUGHLY EXAMINE THE DRAWINGS TO DETERMINE THE SCOPE AND INTENT OF THESE DOCUMENTS AND DRAWINGS. THE CONTRACTOR MUST VISIT THE SITE AND BECOME INFORMED OF ALL EXSISTING CONDITIONS, DIMENSIONS AND LIMITATIONS UNDER WHICH THE WORK IS TO BE PERFORMED. IF ANY DISCREPANCIES OR OMISSIONS ARE DISCOVED THE CONTRACTOR MUST NOTIFY THE DESIGNER. 5. THE CONTRACTOR MUST FURNISH SKILLED LABOR, MATERIAL, EQUIPMENT, APPLIANCES AND SERVICES, AND PERFOM ALL OPERATIONS NECESSARY TO COMPLETE THE WORK IN A SAFE AND WORKMANLIKE MANNER. 6. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. DO NOT SCALE DRAWINGS. 7. ALL MATERIALS AND EQUIPMENT MUST BE INSTALLED PER MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS, AND TO THE BEST INDUSTRY STANDARDS. 8. THE DESIGNER AND HIS CONSULTANTS DO NOT WARRANT OR GUARANTEE THE ACCURACY AND COMPLETENESS OF THE WORK PRODUCT HEREIN. 9. ANY AND ALL SITE DRAWINGS HAVE BEEN FURNISHED TO THE DESIGNER AND ALTHOUGH THE DESIGNER (NPI CONSULTING LLC) MAY HAVE DRAWN THE BUILDING LOCATION AND ALL NEEDED SITE PLANS FOR PERMIT PURPOSES, THE DESIGNER IS NOT RESPONSIBILE FOR THE ACCURACY OF THE SITE PLAN. 10. DESIGNER AND HIS ASSOCIATES LIABILITY AS WELL AS THAT OF NPI CONSULTING LLC, IS LIMITED TO THE COST OF THE PLANS. VI CONSULTING DESIGN DRAFTING RENDERING COPYRIGHT 2023 NPI CONSULTING LLC. ALL RIGHTS RESERVED NPI Consulting LLC 5089 Raesner N. Dr. New Palestine, IN 46163 317-509-1527 npidraftdesign@gmail.com