Loading...
HomeMy WebLinkAbout16-ENG-37 FT Plans Range Line and 116th(reduced)Carmel CLAY TOWNSHIP LOCATION MAP INDIANA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS DATED 2020, INDOT SUPPLEMENTAL SPECIFICATIONS. NO.DATE REVISIONS APPR.BY CERTIFIED BY:DATE PLANS PREPARED BY: OWNER CITY OF CARMEL ONE CIVIC SQUARE CARMEL, INDIANA 46032 (317) 571-2400 TOPOGRAPHIC SURVEY BY: DESIGNED:CHECKED: DRAWN:CHECKED: LORI WATSON - MEMBER BOARD OF PUBLIC WORKS AND SAFETY MARY ANN BURKE - MEMBER JAMES BRAINARD, MAYOR - CHAIRMAN APPROVED BY: PROJECT LOCATION CITY OF CARMEL ROUNDABOUT IMPROVEMENTS CITY OF CARMEL STANDARDS; KEVIN RIDER LAURA CAMPBELL BRUCE KIMBALL SUE FINKAM CITY COUNCIL MEMBERS HONORABLE JAMES BRAINARD, MAYOR Know what'sbelow. before you dig.Call R AMERICAN STRUCTUREPOINT, INC. AMERICAN STRUCTUREPOINT, INC. INDIANAPOLIS, INDIANA 46240 (317) 547-5580 GRAPHIC SCALES 200001000 FEET PROJECT NO. 16-ENG-37 TJM RJC NRM NRM P R O J E C T N O . 1 6 -E N G -3 7 - R O U N D A B O U T I M P R O V E M E N T S Ce n t r a l D r EE 114th St Ce ntral D r W W a sh in g to n Blvd W 116th St S G u ilf o r d Ro a d Mit ch e ll Road Co ll e g e Av e Donnybrook Dr Cla rk St W Carmel Dr Gradle Dr W o o d l a n d D r E 116th St Shoshone Dr E 111th St Woodvalley Dr Pine Valley Dr Je ffe rs o n Dr E C a r m e l C r e e k Carmel Creek R 3 E | R 4 E T 17 N T 18 N Woo d land Ln Ce n t u ry Dr W e s tfie ld B lv d Ke y s to n e P k w y E Carmel Dr Medical Dr Ra ls to n Ave Note: Listed below are the Indiana Underground Plant Protection Services Contacts; Others not listed may exist. UTILITIES surveyor has not physically located the underground utilities. although the surveyor does certify that they are located as accurately as possible from information available. The The surveyor further does not warrant that the underground utilities shown are in the exact location indicated no guarantees that the underground utilities comprise all such utilities in the area, either in-service or abandoned. The underground utilities shown have been located from field survey information and existing drawings. The surveyor makes NOTE: FIBER OPTIC Waylon Higgins (765) 341-1199 New Palestine, IN 46163 5650 Rockway Dr. Zayo Bandwidth Brian Smith (317) 574-2591 Carmel, IN 46032 31 1st Avenue NW Carmel Clay Communications Center SEWER Ryan Hartman (317) 844-9200 Indianapolis, IN 46280 10701 North College Avenue, Suite A Clay Township Regional Waste District APPROVED BY:DATE CITY ENGINEER JEREMY KASHMAN, PE 116TH STREET AND RANGE LINE ROAD S R a n g e Lin e Roa d 1 TITLE SHEET & INDEX SHEET DESIGNATIONSHEET NO. INDEX 8 REFERENCE POINTS CONSTRUCTION DETAILS PLAN AND PROFILES MISCELLANEOUS DETAILS CROSS SECTIONS LINE "PR-RL1" CROSS SECTIONS LINE "PR-S1A" TYPICAL CROSS SECTIONS LIGHTING DETAILS PAVEMENT MARKINGS AND SIGN DETAILS STRUCTURE DATA TABLE 2-4 31-36 53-56 PLAT NO. 16-7 MAINTENANCE OF TRAFFIC DETAILS 40-45 SPOT ELEVATION DETAILS 86 SUMMARY OF QUANTITIES AND APPROACH TABLE 24-30 CROSS SECTIONS LINE "PR-S2A" 1 6 31 36 37-39 ROUNDABOUT ALIGNMENT PLAN LANDSCAPE PLANS IRRIGATION PLANS 21-23 INTERSECTION REMOVAL DETAILS 48-51 RETAINING WALL DETAILS EROSION CONTROL DETAILS CURB RAMP DETAILS UNDERDRAIN TABLE 5 9-20 52 05/07/2021 DOCUMENTS CONSTRUCTION FINAL COMMUNICATION Jeff Rice (317) 610-5438 Indianapolis, IN 46204 240 N. Meridian St. AT & T Mark Mills (217) 876-7194 New Palestine, IN 46163 5650 Rockway Dr. Windstream Brain Cravens (317) 371-1155 Indianapolis, IN 46225 1902 South East St. Level 3 Communications 65-71 72-78 79-85 87-89 90-92 121-126 127-129 HARDSCAPE DETAILS57-64 46-47 FIBER OPTIC Scott Evans (317) 752-6569 Comcast SEWER & WATER Steve Cook (317) 716-3913 City of Carmel Water 9025 RIVER ROAD, SUITE 200 JEFF WORRELL TIM HANNON TONY GREEN MILES NELSON ADAM AASEN 96-120 ELECTRIC Bill Ferrell (317) 776-5351 New Castle, IN 47362 4535 Jane Boulevard Duke Energy GAS Shawn Williams (317) 776-5574 Noblesville, IN 46060 16000 Allisonville Rd. Vectren Brain Cravens (317) 371-1155 Indianapolis, IN 46225 1902 South East St. TCA CABLE TV Byron Posey (317) 538-2016 Indianapolis, IN 46218 3030 Roosevelt Avenue Spectrum Mike Hendricks (317) 571-2634 City of Carmel Sanitary 93-95 WATER PLANS PROJECT PROJECT NO. RANGE LINE CONNECTORS 16-ENG-70 17-ENG-07MEDICAL DRIVE No. ANAIDNI DER ETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 2%2% 4%4% 13 13 KK15 15 2%2% F 1'-0"1'-0"12'-0"12'-0"12'-0"12'-0"2'-0"2'-0"5'-0" 26 Line "PR-RL1" Varies 1.5% LaneLane Lane Lane Profile Grade Profile Grade Subgrade Treatment, Type ICSubgrade Treatment, Type IC 2'-0" Sidewalk Varies 1 1 106+40.00 "PR-RL1" to 107+04.86 "PR-RL1" 2%2% 4%4% 13 13 KK15 15 2%2% 1'-0"1'-0"10'-0"10'-0"10'-0"10'-0"2'-0"2'-0"8'-0" Line "PR-RL1" Varies F1 1.5% LaneLane Lane Lane Profile Grade Profile Grade Subgrade Treatment, Type ICSubgrade Treatment, Type IC Varies 1 1 108+56.87 "PR-RL1" to 109+50.00 "PR-RL1" 6'-0" Buffer 1.5% 2'-0" 1.5% 26 13 R 15 1'-0" 10'-0"10'-0"2'-0" Line "PR-RL1" Lane Lane 109+50.00 "PR-RL1" to 113+75.35 "PR-RL1" 1'-0" 3:1 3: 1 26 Sawcut A Sawcut A 13 1'-0" Subgrade Treatment, Type IC Subgrade Treatment, Type IC Exist.Exist. 2'-0" 2'-0"2'-0" 15 15 F 12'-0"12'-0"12'-0"12'-0"2'-0"2'-0"5'-0" 26 Line "PR-RL1" 1.5% 3: 1 3:1 26 LaneLane Lane Lane Sidewalk 1 1 1 104+00.00 "PR-RL1" to 105+75.00 "PR-RL1" 5'-0" Buffer 1.5% 2'-0" Sawcut Subgrade Treatment, Type IC A 1'-0" R Exist. 1'-0" 3:1 3: 1 26 Subgrade Treatment, Type IC Sawcut 2'-0" 1'-0" Exist. R Exist.Exist.A Existing P.G. Approximate 15 15 2'-0"2'-0" Line "PR-RL1" Lane 1 1 105+75.00 "PR-RL1" to 106+40.00 "PR-RL1" Sawcut Subgrade Treatment, Type IC A 1'-0" R1 Subgrade Treatment, Type IC Sawcut 1'-0" R1 A 2%2%2%2% Sawcut 4% A 13 Profile Grade 4% Sawcut A Profile Grade Subgrade Treatment, Type IC Subgrade Treatment, Type IC Varies Varies Varies; See Construction Details and Roundabout Alignment Details 1 12'-0"12'-0" Exist. Pavement Exist. Pavement Exist. Pavement 13 2'-0"2'-0" Lane 12'-0"12'-0" LaneLane 2'-0" 1'-0"1'-0" Shared-Use Path 6'-0" Buffer 1.5% 26 2'-0" Exist. Pavement 8'-0" F1 1.5% Shared-Use Path 6'-0" Buffer 1.5% 26 R15 1'-0" 10'-0"10'-0"2'-0" LaneLane 1'-0" 3:1 3:1 26 Sawcut A Sawcut A 13 4% 1'-0" Subgrade Treatment, Type IC Subgrade Treatment, Type IC Exist.Exist. 2'-0" Exist. Pavement 8'-0" F1 1.5% Shared-Use Path 5'-0" Buffer 1.5% 26 9'-0"9'-0"1 1 4% Exist. Pavement Sawcut A Subgrade Treatment, Type IC Existing Ground Existing Ground Existing Ground Existing Ground 1.5% F 1.5% 6'-0"5'-0"1'-0" Sidewalk Buffer 26 Varies Varies F 5'-0" 26 1.5% Sidewalk 6'-0" Buffer 1.5% 1'-0" 3:1 3: 1 26 1 Existing Ground 1.5% 6'-0" Buffer 26 WESTFIELD BLVD. WESTFIELD BLVD. WESTFIELD BLVD. RANGE LINE ROAD RANGE LINE ROAD 1'-0" 3:1 3:1 26 Existing Ground 1.5% 6'-0" Buffer 26 3'-0" 3:1 3:1 26 Existing Ground 1'-0" 1.5% F1 8'-0" Shared-Use Path Buffer 1 1 '-6 " 4" Ø Open Conduit 4" Ø Innerduct CONDUIT/INNERDUCT DETAIL For additional details, see City of Carmel Standard Drawing No. 10-44. For location, see Lighting Details. NOTES: 3 '- 0 " Co v e r (Directly Over Conduit) Polyethylene Identification Tape 1 '-6 " (Directly Over Conduit) Polyethylene Identification Tape 3 '- 0 " Co v e r 4" Ø Innerduct4" Ø Open Conduit 1 '- 6 " (Directly Over Conduit) Polyethylene Identification Tape 3 '- 0 " Co v e r 4" Ø Innerduct4" Ø Open Conduit 3:1 3:1 26 Existing Ground 1.5% F 5'-0"1'-0" Sidewalk 1 '-6 " 4" Ø Open Conduit 4" Ø Innerduct 3 '- 0 " Co v e r (Directly Over Conduit) Polyethylene Identification Tape 3: 1 3:1 26 Existing Ground 1.5% F 5'-0"1'-0" Sidewalk 1 '-6 " 4" Ø Open Conduit 4" Ø Innerduct 3 '- 0 " Co v e r (Directly Over Conduit) Polyethylene Identification Tape 1 R15 From 113+25.00 "PR-RL1" to 113+75.35 "PR-RL1" 3 5 2 2 2 22 to Exist. Cross Slope at 104+40.00 "PR-RL1" Transition from 2% Cross Slope at 104+00.00 "PR-RL1" U U U U U U U U U U CONDUIT/INNERDUCT DETAIL CONDUIT/INNERDUCT DETAIL CONDUIT/INNERDUCT DETAIL CONDUIT/INNERDUCT DETAIL CONDUIT/INNERDUCT DETAIL See Landscape Plans See Landscape Plans See Landscape Plans See Landscape Plans 3 3 4 4 No Shared-Use Path; See Construction Details from 109+50.00 "PR-RL1" to 110+69.71 "PR-RL1" No Shared-Use Path; See Construction Details from 108+72.78 "PR-RL1" to 109+50.00 "PR-RL1" LEGEND K R 165 #/Sys. HMA Surface, Type "C", 9.5mm Milling, Asphalt, 1.5" 330 #/Sys. HMA Base, Type "C", 25.0mm 250 #/Sys. HMA Interm., Type "C", OG, 19.0mm on 385 #/Sys. HMA Base, Type "C", 25.0mm on 275 #/Sys. HMA Interm., Type "C", 19.0mm on 165 #/Sys. HMA Surface, Type "C", 9.5mm on Sodding, Nursery 15 16 26 Straight Concrete Curb13 Curb & Gutter Concrete Type II Sidewalk, Concrete, 4 in. A F1 F C Subgrade Treatment Type II PCCP for Approaches, 6 in., on R1 Milling, Asphalt, Variable Depth (1" Min.) HMA Wedge & Level, Type C on 385 #/Sys. HMA Interm., Type "C", 19.0mm on 165 #/Sys. HMA Surface, Type "C", 9.5mm on T 10 in. of Compacted Aggregate No. 53 Decorative Concrete Pavement, Truck Apron, 7" U Underdrain, 6 in. (See Miscellaneous Details) Roll Curb for Truck Apron 14 Straight Concrete Curb, Modified Compacted Subgrade 6" Compacted, Aggregate No. 53 on 275#/Sys. HMA Intermediate, Type "B", 19.0 mm on 165#/Sys. HMA Surface, Type "B", 9.5 mm on Shared-Use Path 6 in. Concrete Class "A" 165 #/Sys. HMA Surface, Type "C", 9.5mm on 22 Center Curb, Type D 1/4" = 1'-0" RANGE LINE ROAD AND 116TH STREET BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 2 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TY.01.dgn5/24/2021 02:24:54 PMjhofman FOR APPROVAL RECOMMENDED Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 TYPICAL CROSS SECTIONS 1/4" = 1'-0" TJM RJC NRM NRM 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 2%2% 4%4% 13 13 KK15 15 2%2% F 1'-0"1'-0"11'-0"11'-0"11'-0"11'-0"2'-0"2'-0"5'-0" Exist. Pavement 26 Line "PR-S1A" Varies 1.5% LaneLane Lane Lane Profile Grade Profile Grade Subgrade Treatment, Type ICSubgrade Treatment, Type IC Sidewalk Varies 1 1 3'-0" Buffer 1.5% 13 A Sawcut 116TH STREET 2'-0"2'-0" R 15 1'-0" 10'-0"10'-0"2'-0" Line "PR-RL1" Lane Lane 1'-0" 3:1 3:1 26 Sawcut A Sawcut A 13 3'-0" 4%4%R15 1'-0" 10'-0"10'-0"2'-0" LaneLane Sawcut A Sawcut A 1'-0" 13 1'-0" Subgrade Treatment, Type IC Subgrade Treatment, Type IC Subgrade Treatment, Type IC Exist.Exist.Exist.Exist. 2'-0"2'-0" Exist. PavementExist. Pavement 8'-0" F1 1.5% Shared-Use Path 6'-0" Buffer 1.5% 26 1'-0" 3:1 3:1 26 8'-0" F1 1.5% Shared-Use Path 6'-0" Buffer 1.5% 26 4% 13 15 1'-0"12'-0"12'-0"2'-0" Line "PR-S1A" LaneLane 116TH STREET Exist.Exist. Sawcut A Exist. PavementSawcut Subgrade Treatment, Type IC 2'-0" A 1'-0" R 5'-0" 4% 13 15 1'-0"12'-0"12'-0"2'-0" Lane Lane Exist.Exist. Sawcut A Exist. Pavement Sawcut Subgrade Treatment, Type IC 2'-0" A 1'-0" R 5'-0" Subgrade Treatment, Type IC Subgrade Treatment, Type IC 36+83.04 "PR-S1A" to 38+60.00 "PR-S1A" 34+15.00 "PR-S1A" to 35+29.87 "PR-S1A" 3: 1 26 1'-0"1'-0" Subgrade Treatment, Type IC Existing Ground Existing Ground RANGE LINE ROAD 38+60.00 "PR-S1A" to 39+55.00 "PR-S1A" 32+80.00 "PR-S1A" to 33+44.00 "PR-S1A" 1'-0" 3:1 3:1 26 8'-0" F1 1.5% Shared-Use Path 6'-0" Existing Ground 1.5% 26 Buffer 1'-0" 3:1 3:1 26 8'-0" F1 1.5% Shared-Use Path 6'-0" Existing Ground 1.5% 26 Buffer 1 1'-0" 3:1 3:1 26 6'-0" Existing Ground 1.5% 26 Buffer 5'-0" 1.5% Sidewalk F 1 '-6 " (Directly Over Conduit) Polyethylene Identification Tape 3 '- 0 " C o v e r 4" Ø Open Conduit 4" Ø Innerduct CONDUIT/INNERDUCT DETAIL 1 '- 6 " (Directly Over Conduit) Polyethylene Identification Tape 3 '-0 " Co v e r 4" Ø Open Conduit 4" Ø Innerduct 1 '-6 " (Directly Over Conduit) Polyethylene Identification Tape 3 '- 0 " C o v e r 4" Ø Open Conduit 4" Ø Innerduct 3'-0" Varies; See Construction Details and Roundabout Alignment Details1 1 1 11 115+10.41 "PR-RL1" to 122+12.93 "PR-RL1" 113+75.35 "PR-RL1" to 114+11.39 "PR-RL1" 1 1 2'-0" F 5'-0" 1.5% Sidewalk 1'-0" 3:1 3: 1 26 Existing Ground SIDEWALK DETAIL 36+83.04 "PR-S1A" to 38+35.70 "PR-S1A" 15 2'-0"8'-0" F1 1.5% Shared-Use Path 6'-0" Buffer 12:1 26 15 2'-0"8'-0" F1 1.5% Shared-Use Path 3'-0" Buffer 12:1 26 113+99.50 "PR-RL1" to 114+35.62 "PR-RL1" RT.113+88.99 "PR-RL1" to 114+47.15 "PR-RL1" LT. SHARED-USE PATH DETAILSHARED-USE PATH DETAIL U U U U U U CONDUIT/INNERDUCT DETAIL CONDUIT/INNERDUCT DETAIL CONDUIT/INNERDUCT DETAIL For additional details, see City of Carmel Standard Drawing No. 10-44. For location of Conduit, see Lighting Details. NOTES: See Landscape Plans See Landscape Plans See Landscape Plans 15 1'-0"11'-0"11'-0"2'-0" LaneLane 116TH STREET Exist.Exist. SawcutExist. PavementSawcut Subgrade Treatment, Type IC 2'-0" A 1'-0" R 11'-0" 15 1'-0"11'-0"11'-0"2'-0" Lane Lane Exist.Exist. Sawcut A Exist. Pavement Sawcut Subgrade Treatment, Type IC 2'-0" A 1'-0" R Subgrade Treatment, Type IC Subgrade Treatment, Type IC 1'-0" 3:1 3:1 26 8'-0" F1 1.5% Shared-Use Path 6'-0" Existing Ground 1.5% 26 Buffer 1'-0" 3:1 3:1 26 6'-0" Existing Ground 1.5% 26 Buffer 5'-0" 1.5% Sidewalk F1 '-6 " (Directly Over Conduit) Polyethylene Identification Tape 3 '-0 " Co v e r 4" Ø Open Conduit 4" Ø Innerduct U U CONDUIT/INNERDUCT DETAIL Line "PR-S1A" 33+44.00 "PR-S1A" to 34+15.00 "PR-S1A" 2% Varies 1 KProfile Grade 22 3 Left Turn Lane 3 3 3 3 5 4 4 4 No Median Stand Up Curb from Station 32+80.00 "PR-S1A" to 33+44.00 "PR-S1A" Lane width is 11'-0" from Station 32+80.00 "PR-S1A" to 33+44.00 "PR-S1A" 5 5 5 5 Lane width is 12'-0" from Station 36+83.04 "PR-S1A" to 38+60.00 "PR-S1A" 2 2 No Shared-Use Path; See Construction Details from Station 115+10.41 "PR-RL1" to 117+09.60 "PR-RL1" LEGEND K R 165 #/Sys. HMA Surface, Type "C", 9.5mm Milling, Asphalt, 1.5" 330 #/Sys. HMA Base, Type "C", 25.0mm 250 #/Sys. HMA Interm., Type "C", OG, 19.0mm on 385 #/Sys. HMA Base, Type "C", 25.0mm on 275 #/Sys. HMA Interm., Type "C", 19.0mm on 165 #/Sys. HMA Surface, Type "C", 9.5mm on Sodding, Nursery 15 16 26 Straight Concrete Curb13 Curb & Gutter Concrete Type II Sidewalk, Concrete, 4 in. A F1 F C Subgrade Treatment Type II PCCP for Approaches, 6 in., on R1 Milling, Asphalt, Variable Depth (1" Min.) HMA Wedge & Level, Type C on 385 #/Sys. HMA Interm., Type "C", 19.0mm on 165 #/Sys. HMA Surface, Type "C", 9.5mm on T 10 in. of Compacted Aggregate No. 53 Decorative Concrete Pavement, Truck Apron, 7" U Underdrain, 6 in. (See Miscellaneous Details) Roll Curb for Truck Apron 14 Straight Concrete Curb, Modified Compacted Subgrade 6" Compacted, Aggregate No. 53 on 275#/Sys. HMA Intermediate, Type "B", 19.0 mm on 165#/Sys. HMA Surface, Type "B", 9.5 mm on Shared-Use Path 6 in. Concrete Class "A" 165 #/Sys. HMA Surface, Type "C", 9.5mm on 22 Center Curb, Type D 1/4" = 1'-0" RANGE LINE ROAD AND 116TH STREET BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 3 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TY.02.dgn5/24/2021 02:24:55 PMjhofman FOR APPROVAL RECOMMENDED Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 TYPICAL CROSS SECTIONS 1/4" = 1'-0" TJM RJC NRM NRM 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 ROUNDABOUT TYPICAL SECTION RANGE LINE ROAD AND MEDICAL DRIVE Roundabout Center 2% 4% 2%* K 5'-0"12'-0"2'-0" Center Island 15'-0"15'-0" T 16 13 Lane LaneTruck Apron Subgrade Treatment, Type IC Subgrade Treatment, Type IC MEDICAL DRIVE/ACCESS DRIVEWAY 4%4% 13 13 VariesVaries 1 1 Line "PR-S2A" 1'-0"1'-0"11'-0" 15 11'-0" 15 2'-0"2'-0" 3:1 3:1 Existing Ground 26 2'-0" 3:1 3:1 Existing Ground 26 2'-0" R R Sawcut A 1'-0" 2'-0" Sawcut Subgrade Treatment, Type IC A Sawcut Sawcut Subgrade Treatment, Type IC A 1'-0" A 2'-0" 1'-0" Lane Lane *See Spot Elevation Details NOTE: Exist.Exist. Varies; See Construction Details and Roundabout Alignment Details1 1 *2% 13 1 1 MEDICAL DRIVE/ACCESS DRIVEWAY 4%4% 13 13 VariesVaries 1 1 Line "PR-S2A" 1'-0"1'-0"11'-0" 15 11'-0" 15 2'-0"2'-0" 3:1 3:1 Existing Ground 26 2'-0"3'-0" R1 R1 Sawcut A 1'-0" 2'-0" Sawcut Subgrade Treatment, Type IC A Sawcut Sawcut Subgrade Treatment, Type IC A 1'-0" A 2'-0" Lane Lane Exist.Exist. 1 1 1 13+12.06 "PR-S2A" to 13+75.00 "PR-S2A" 13+75.00 "PR-S2A" to 14+06.00 "PR-S2A" 10+90.00 "PR-S2A" to 11+38.31 "PR-S2A" F 5'-0" 26 1.5% Sidewalk 2'-0" Buffer 12:1 Modular Block Retaining Wall 1.5% 15 2'-0"3'-0" A 1'-0" F 5'-0" 26 1.5% Sidewalk 2'-0" Buffer 12:1 Modular Block Retaining Wall Sawcut A Subgrade Treatment, Type IC 1.5% Subgrade Treatment, Type IC 1 2'-0" SIDEWALK DETAIL 13+75.00 "PR-S2A" to 14+06.00 "PR-S2A" Exist. Pavement No. 53 Base on Geotextiles Compacted Aggregate 13 1'-0" No. 53 Base on Geotextiles Compacted Aggregate Sawcut A Subgrade Treatment, Type IC Exist. Pavement 13 1'-0" U U U U U 1.5% 1.5% See Landscape Plans See Landscape Plans 26 Roundabout Center 4% ROUNDABOUT TYPICAL SECTION 37'-0"8'-0"2'-0"14'-0"2'-0"14'-0"3'-0" 13 T 16 K 15 F 2%2% 2% Center Island Truck Apron Lane Lane 26 5'-0" 1.5%1.5%3:1 3:1 26 Sidewalk 1'-0" Subgrade Treatment, Type IC Buffer 11 2'-0" ** Existing Ground RANGE LINE ROAD AND 116TH STREET *See Spot Elevation Details NOTE: U See Landscape Plans LEGEND K R 165 #/Sys. HMA Surface, Type "C", 9.5mm Milling, Asphalt, 1.5" 330 #/Sys. HMA Base, Type "C", 25.0mm 250 #/Sys. HMA Interm., Type "C", OG, 19.0mm on 385 #/Sys. HMA Base, Type "C", 25.0mm on 275 #/Sys. HMA Interm., Type "C", 19.0mm on 165 #/Sys. HMA Surface, Type "C", 9.5mm on Sodding, Nursery 15 16 26 Straight Concrete Curb13 Curb & Gutter Concrete Type II Sidewalk, Concrete, 4 in. A F1 F C Subgrade Treatment Type II PCCP for Approaches, 6 in., on R1 Milling, Asphalt, Variable Depth (1" Min.) HMA Wedge & Level, Type C on 385 #/Sys. HMA Interm., Type "C", 19.0mm on 165 #/Sys. HMA Surface, Type "C", 9.5mm on T 10 in. of Compacted Aggregate No. 53 Decorative Concrete Pavement, Truck Apron, 7" U Underdrain, 6 in. (See Miscellaneous Details) Roll Curb for Truck Apron 14 Straight Concrete Curb, Modified Compacted Subgrade 6" Compacted, Aggregate No. 53 on 275#/Sys. HMA Intermediate, Type "B", 19.0 mm on 165#/Sys. HMA Surface, Type "B", 9.5 mm on Shared-Use Path 6 in. Concrete Class "A" 165 #/Sys. HMA Surface, Type "C", 9.5mm on 22 Center Curb, Type D 1/4" = 1'-0" RANGELINE ROAD AND MEDICAL DRIVE BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 4 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TY.03.dgn5/24/2021 02:24:55 PMjhofman FOR APPROVAL RECOMMENDED Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 TYPICAL CROSS SECTIONS 1/4" = 1'-0" TJM RJC NRM NRM 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 TYPICAL CENTER CURB TYPE D DETAIL Top Pvm't. SECTION K-K Scale: 1/2" = 1'-0" 7 1 / 2 " 6 " Varies 2 1/2"2 1/2" 1 1/2"R(Typ.) Curb Ramp Curb Ramp 15 15 13 13 13 13 C C A JOINT LEGEND B C D Control Joint 6'-0"10'-0"6'-0" D D6"6" A 9'-0" 24:1 (Max.)24:1 (Max.) RAISED PEDESTRIAN CROSSING DETAILS No Scale PLAN No Scale A A 6'-0"10'-0"6'-0" 1 '- 1 " 3 " 7 1 / 2 " Top of Curb 6"6"9'-0" D and Asphalt Pavement (Typ.) All Interfaces of Concrete Tack Coat to be Provided at D (See Spot Eelevations) (Typ. Both Sides) of Pavement Elevation 3" Higher than Edge (Typ. Both Sides) to Pouring Colored Conc. to Face of Gray Conc. Prior Apply Epoxy Bonding Agent Top of Curb TYPICAL SECTION A-A (Clay Pavers on PCCP) A (Clay Pavers Crosswalk) Smooth Dowel 12" O.C. (Typ.) 1"Ø x 1'-6" Epoxy Coated 45° Herringbone Pattern 3/4" Rolled Bituminous Setting Bed on Neoprene Asphalt Adhesive, on Interlocking Clay Pavers (3 1/4" Depth), 6 1 / 2 " Detectable Warning Surface Detectable Warning Surface 2 '-0 " 2 '- 0 " Joint Material 1/2" Expansion Joint Material 1/2" Expansion Joint Material 1/2" Expansion Joint Material 1/2" Expansion Expansion Joint Construction Joint Sawcut Control Joint No Scale D / 2 D / 2 Sawcut 1/4" x 1/4" D Smooth Dowel 12" O.C. 1"Ø x 1'-6" Epoxy Coated No Scale D / 2 D/ 2 Smooth Dowel 12" O.C. 1"Ø x 1'-6" Epoxy Coated No Scale D / 2 D / 2 Smooth Dowel 12" O.C. 1"Ø x 1'-6" Epoxy Coated Joint Material 1/2" Expansion 6 '-0 " 3 '- 0 " 6'-0" 1 2 " 1 2 " No Scale RAISED PEDESTRIAN PAVEMENT MARKING DETAIL EXPANSION JOINT DETAIL (30' O.C. MAX.) CONSTRUCTION JOINT DETAIL (10' O.C. MAX.) SAWCUT CONTROL JOINT DETAIL (10' O.C. MAX.) Direction of Traffic � of Lane PLAN 13 13 K K JJ (Typ.) 6" (Typ .) 6 " RPM (Yellow) (Typ.) Top Pvm't. 13 6'-0" 6 " 7 1 / 2 " (12:1 Taper) SECTION J-J 7 1 / 2 " 1 1 5 / 8 " 2'-0" 5/8 " 1'-2" R R 1'-2" 4 " Scale: 1" = 1'-0" 7 5 / 8 " Carmel Standard Drawing No. 10-25C NOTE: For additional details, see City of ROLL CURB FOR TRUCK APRON DETAIL Scale: 1" = 1'-0" STRAIGHT CONCRETE CURB, MODIFIED 2 '-0 " 4" 6" 2" R 9" 1 '-0 " Ma x. 6" to 3" (typ.) Curb Height Transition No Scale INLET PERIMETER DRAIN DETAIL 2'-0" ELEVATION PLAN 5 '-0 " Proposed Storm Sewer Pipe Cap End of Pipe Wrapped in Filter Cloth 6" Dia. Underdrain Pipe Inlet Perimeter Drain Locations Additional Information on Inlet See Underdrain Table for NOTE: Inlet Subgrade Treatment Subgrade Treatment Storm Sewer Pipe Structure Backfill, Type 2 Limits in Filter Cloth, Placed within 6" Dia. Underdrain Pipe Wrapped 1 8 " Underdrain Trench Without 15 K (PCCP Class C Concrete)(PCCP Class C Concrete) (Class C Concrete) PCCP (Class C Concrete) PCCP (Class C Concrete) PCCP 9 1/3" - Full Depth HMA Pvm't. on Subgrade Teatment, Type 1C At Medical Drive: Swept Joints (1/4" Max.) Hand Tight Polymeric Sand LEGEND (See Typical Sections) Full Depth HMA Pavement F1 K X T (See Typical Sections) PCCP Truck ApronC C1 F (See Carmel Std. Dwg. 10-18) Sidewalk, Concrete, 4 In. K1 (Full Depth Pavement) HMA for Approaches R 28A Mill 1.5 in. & Resurface R1 (See Typical Sections) HMA Wedge & Level 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D (See City of Carmel Std. 10-25C) Roll Curb for Truck Apron (See Typical Sections) Widening with PCC Base, 6" Type C (Full Depth Pavement) HMA For Structure Installation, (Full Depth Pavement) Widening with HMA, Typc C (See Miscellaneous Details) Raised Pedestrian Crossing Subgrade Treatment Type II PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on 14 Straight Concrete Curb, Modified (See Curb Ramp Details) Curb Ramp, Concrete (See Typical Sections) Shared-Use Path 17 Curb & Gutter, Concrete, Type III 4 (See Landscape Plans) Planting Areas MISCELLANEOUS DETAILS AS NOTED N/A BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 5 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.MD.01.dgn5/24/2021 09:42:46 AMjhofman FOR APPROVAL RECOMMENDED Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 TJM RJC NRM NRM 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 1 0 5 1 1 0 25+0020+00 15+00 4 0 + 0 0 3 5 + 0 0 2 0 + 0 0 HAMILTON COUNTY CLAY TOWNSHIP SEC. 1, T 17 N, R 3 E GRAHAME D. & DIANA J. CURTS C ar m el C k. App. Exist. R/WApp. Exist. R/W App. Section Line App. Exist. R/W ASSOCIATION INC HOMEOWNERS CREEKSIDE HAMILTON COUNTY CLAY TOWNSHIP SEC. 6, T 17 N, R 4 E ASSOCIATION INC HOMEOWNERS CREEKSIDE App. P.L.App. P.L.App. Exist. R/W Line "RL" & "PR-RL1" CORNER ASSOCIATES LP Ap p . Ex is t. R/ W 1 1 6 t h S t. Line "PR-RL1" Lin e "P R- S1 A" Lin e "S- 1 -A" SPEEDWAY LLC HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E Ap p . S e c ti o n Lin e Ap p . Exist. R /WAp p . Exis t. R / W App. Exist. R/W Line "RL" HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E Ap p . Ex is t. R/ W KRG CENTRE LLC Lin e "S-1 -A" & "PR-S1 A" App. Exist. R/W App. Exist. R/W C r e e k s id e D r. Lot F Lot G Replat - Block A Creekside Common Area A Common Area B PROPERTY GROUP LLC MILLER McCOMAS 104+00.00 "PR-RL1" BEGIN PROJECT Ap p . Ex is t. R/ W R/W R/W Lin e "S -1 -A" & "P R -S 1 A"1 1 6 t h S t. P.I. 20+00.00 "S-1-A" P.I. 20+00.00 "RL" = App. Exist. R/W App. Exist. R/W Range Line Rd. Westfield Blvd. Ap p . Exis t. R /W Ap p . Exist. R /W ASSOCIATION INC HOMEOWNERS FAIRGREEN TRACE BUILDING CORPORATION CARMEL CLAY PARKS E ase m ent No Acc e ss Ease ment S.D. & U. 15 ' Uti l i t y Ease m ent 15 ' Uti l i t y Easement 32+80.00 "PR-S1A" BEGIN CONSTRUCTION 39+55.00 "PR-S1A" END CONSTRUCTION P.O.T. 12+00.00 "RL" P.O.T. 100+00.00 "PR-RL1" = WOODLAND SHOPPES Utility Easement Utility Easement Acc e ss Ease ment Acc e ss Easement S H O P P E S W O O D L A N D ACQUISITION CORPORATION VCA REAL PROPERTY AUTOZONE INC Blankey Drainage Easement Block "B" Common Area FAIRGREEN TRACE, PHASE 2 R/W R/W R/W R/ W R /W Line "RL" & "PR-RL1" Temp. R/W T e m p . R/ W Temp. R/W Temp. R/W P.O.T. 19+90.00 "RL" P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = T e m p . R/ W Temp. R/W Temp. R/W Temp. R/WTemp. R/W COYOTE ENTERPRISES, INC. App. P.L. R/W App. P.L. App. P.L. R/W 1"=50' N/A PLAT NO. 1 RJCTJM NRM NRM BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 6 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PL.01.dgn5/24/2021 09:42:47 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 1 1 5 1 2 0 1 2 5 1 0 + 0 0 30+00 35+00Line "RL" & "PR-RL1" HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 EKRG CENTRE LLC App. Exist. R/W App. Exist. R/W Range Line Rd. AUTOZONE INC App. Exist. R/WApp. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Section Line App. Exist. R/W Ap p . Exist. R/ W Ap p . Exis t. R / W M e d ica l D r . II COMPANY BARNES INVESTMENTS FINEBERG GROUP LLC OPERATIONS LLC BFS RETAIL & COMMERCIAL STORES LLC MACS CONVENIENCE FINEBERG GROUP LLC E N T E R P R I S E S J & J R E A L T Y Utility Easement Utility Easement C a rm e l D r. C a r m e l D r . LIVING TRUST REVOCABLE PATRICIA R. EMMERT LLC D & W HOLDINGS 2 0 0 Ap p . Exist. R/ W Ap p . Exis t. R / W CITY OF CARMEL CARMEL DEVELOPMENT II LLC App. Exist. R/W App. Exist. R/W App. Exist. R/W PTN 1 REAL ESTATE DEPT KROGER LIMITED COMPANY BARNES INVESTMENT COMPANY BARNES INVESTMENT Ap p . Ex is t . R/ W 122+12.93 "PR-RL1" INCIDENTAL CONSTRUCTION END PROJECT & BEGIN Temp. R/W Temp. R/W App. Exist. R/W P.O.T. 10+00.00 "S-2-A" P.O.T. 26+75.74 "RL" = P.O.T. 114+77.31 "PR-RL1" = Lin e "S -2 -A" Lin e "S -2 -A" 1 0 + 0 0 1 5 + 0 0 Lin e "PR -S 2 A" Lin e "S -2 -A" & "PR -S 2 A" P.O.T. 12+32.76 "PR-S2A" P.O.T. 114+61.91 "PR-RL2"= 14+06.00 "PR-S2A" END CONSTRUCTION 10+90.00 "PR-S2A" BEGIN CONSTRUCTION Temp. R/W 124+63.91 "PR-RL1" END INCIDENTAL CONSTRUCTION R/W R/W Temp. R/W Temp. R/W Temp. R/W R / W T e m p . R / W T e m p . R/ W Temp. R/W R/W App. Exist. R/W App. Exist. R/W R/W Temp. R/W Temp. R/W Line "RL" 836.0848344BRK TJM NRM RJC NRM PLAT NO. 1 N/A 1"=50' BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 7 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PL.02.dgn5/24/2021 09:42:48 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 N:715180.066 / E:9419.447 CONTROL POINT #171 N:715594.943 / E:9066.256 CONTROL POINT #172 N:716112.420 / E:9068.881 CONTROL POINT #173 N:716910.824 / E:9047.426 CONTROL POINT #174 T T edge of pavement 8.35' ne cor sign base 5.78' mag in pwp #188474 38.38' 116th St. Conc Asph Sidewalk R a n g e li n e R dS id e w a lk mag nail found mag nail set back of curb 6.84' ne cor tele box 6.57' back of curb 62.31' 1352 S. Rangeline Rd.S id e w a lk Sidewalk R a n g e li n e R d mag nail set back of curb 3.81' se cor of building 25.53' cor of sidewalk 21.73' R a n g e li n e R d Carmel Dr mag nail set ne bolt fiber vault 3.37' face of flag pole 23.14' back of curb 3.83'Sidewalk S id e w a lk Section Corner #17030103 N:1715219.424 / E:199112.252 NE Corner 01-17-03 East Section Corner #17030106 N:1712394.280 / E:199075.070 01-17-03 East4 1SE Corner Ne Section Corner #17030111 N:000.000 / E:000.000 01-17-03 East4 1 NE 4 1NE Corner NW RTRT RT RTHYDSection Corner #18033603 N:1720517.210 / E:199062.250 NE Corner 36-18-03 East Section Corner #18043102 N:1720531.068 / E:201646.554 31-08-04 East4 1NE Corner NW Section Corner #18043105 N:1717872.691 / E:201743.649 31-18-04 EastHYDBrass Pin w/Casting mag se cor traffic signal base 75.62' mag se cor traffic signal base 82.92' mag se cor traffic signal base 74.81' mag se cor traffic signal base 76.88' R a n g e li n e R d 116th St. Harrison Set @ Surface mag ne cor util pole #05-253 40.65' mag nw cor util pole 69.65' mag s cor util pole 94.77' top hydrant nut 65.49' 111th St. W e s f ie ld B lv d Stone found 116th St. pk nail in tele pole 63.56' pk nail in tele pole 52.12' Witt. stone 19.90' pk nail in tele pole 87.07' Brass pin Harrison monument 21.15' mag in top of curb 11.95' mag in top of curb 4.53'mag in top of curb 9.95'R a n g e li n e R d Conc RR Spike mag w side 24" maple 25.58' mag n side walk 38.75' mag n side walk 33.28' mag n side walk 38.80' 126th St Brass pin mag s side 20" hackberry 11.28' mag barricade post 18.86' cut "x" top nut hydrant 16.78' mag barricade post 17.27' Mohawk Hills Apartments Loading dock Section Corner #18043108 N:1715226.246 / E:201818.944 31-18-04 East4 1SE Corner SW Section Corner #17030105 N:1712476.640 / E:196399.040 01-17-03 East Section Corner #17040602 N:1715226.104 / E:201907.621 06-17-04 East4 1NE Corner NW Section Corner #18033608 N:1715211.621 / E:196456.630 36-18-03 East4 1 SW 4 1SE Corner SE Harrison mag top of curb 11.04' mag top of curb 4.68' mag top of curb 11.04' mag w/washer 88.68' 116th St RR Spike HSCO mag in conc 12.80' HSCO mag in conc 11.55' HSCO mag in conc 18.65' HSCO mag in conc 18.00' 111th St M o n o n T r a il Mag spike 116th St mag top of curb 11.03' mag top of curb 4.81' mag top of curb 12.18' Harrison 88.68' Harrison ne cor brick wall 45.11' nw cor brick wall 49.73 se cor brick wall 65.66' sw cor brick wall 68.73' Mo n o n Tu n n e l REFERENCE POINTS TJM NRM RJC NRM ALIGNMENT STATION NORTHING EASTING "RL"P.O.T. 12+00.00 714,419.462 9,101.5164 P.O.T. 20+00.00 715,219.393 9,112.02 P.O.T. 37+52.81 716,972.0054 9,086.0046 P.O.T. 46+50.29 717,869.391 9,072.684 P.O.T. 46+61.50 717,880.5989 9,072.639 P.O.T. 46+89.14 717,908.2407 9,072.5279 P.O.T. 50+18.95 718,238.048 9,071.2024 P.O.T. 54+58.34 718,677.4345 9,069.4366 P.O.T. 56+19.20 718,838.2958 9,068.7901 P.O.T. 65+12.00 719,731.086 9,065.2022 P.O.T. 71+36.66 720,355.7371 9,062.6918 P.O.T. 72+98.35 720,517.43 9,062.042 P.O.T. 73+19.50 720,538.5845 9,062.0472 P.O.T. 76+05.31 720,824.39 9,062.118 P.O.T. 78+35.00 721,054.076 9,062.1748 P.O.T. 84+72.20 721,691.276 9,062.3326 P.O.T. 88+37.70 722,056.776 9,062.4231 P.O.T. 90+09.70 722,228.776 9,062.4657 P.O.T. 92+00.00 722,419.076 9,062.5128 P.O.T. 99+40.20 723,159.276 9,062.696 ALIGNMENT STATION NORTHING EASTING "PR-RL1"P.O.T. 100+00.00 714,419.462 9,101.5164 P.C. 106+08.38 715,027.7849 9,109.5041 P.I. 106+34.97 715,054.3785 9,109.8532 P.R.C. 106+61.52 715,080.8641 9,107.4344 P.I. 106+87.87 715,107.1091 9,105.0376 P.T. 107+14.12 715,133.4043 9,106.7989 P.C. 107+90.28 715,209.3939 9,111.8887 P.I. 108+56.97 715,274.3374 9,127.053 P.R.C. 109+21.92 715,340.1119 9,116.0382 P.I. 109+60.52 715,378.181 9,109.663 P.T. 109+98.97 715,416.7759 9,109.0901 P.O.T. 125+54.37 716,972.0054 9,086.0046 ALIGNMENT STATION NORTHING EASTING "PR-S1A"P.O.T. 30+00.00 715,217.6292 8,512.0226 P.C. 33+31.06 715,218.6024 8,843.0819 P.I. 33+63.03 715,218.6964 8,875.0540 715,214.4597 8,906.7444 P.I. 34+98.11 715,200.7834 9,009.0414 715,209.3939 9,111.8887 715,185.4328 9,182.5544 715,204.1244 9,254.7929 P.I. 38+08.54 715,219.9058 9,315.7842 P.O.T. 42+04.12 715,220.9029 9,712.0181 N/A N/A ALIGNMENT STATION NORTHING EASTING "S-2-A"715,895.0619 9,101.9905 715,893.7954 9,501,9885P.O.T. 14+00.00 P.R.C. 33+94.91 P.T./P.C. 36+00.51 P.I. 36+75.13 P.R.C. 37+45.54 P.T. 38+70.88 715,220.0643 9,378.7839 P.O.T. 10+00.00 ALIGNMENT STATION NORTHING EASTING "PR-S2A"P.O.T. 10+00.00 715,896.4387 8,871.4181 P.C. 11+20.72 715,896.4387 8,992.1413 P.I. 11+50.96 715,896.4387 9,022.3828 715,889.2278 9,051.7521 P.I. 12+25.69 715,878.5517 9,095.2348 715,891.5980 9,177.3085 715,894.7604 9,197.2029 715,894.6966 9,216.5555 P.O.T. 15+00.00 715,894.2185 9,368.3526 P.I. 13+28.94 P.T. 11+80.91 P.C. 13+08.79 P.T. 13+48.99 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 8 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.GE.01.dgn5/24/2021 09:42:49 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Ke ys t o n e P k w y . E 116th St. Medical Dr. maintained throughout the duration of the project. Access to all businesses and residential properties shall be NOTE: HA E E D DA S OR DA OLC DETOUR AHEAD Road Closure Sign Assembly, Type 1 (48"x18") XM 4-10 (L or R) (48" x 48") XW 20-2 W Carmel Dr.E Carmel Dr. XD 3-1 XM 4-8 XM 4-6 DRMA 6 M 6-1 (L) XD 3-1 XM 4-8 DRMA 1 M 5-1 (L) XD 3-1 XM 4-8 DRMA 2 M 6-1 (R) XD 3-1 XM 4-8 DRMA 3 M 5-1 (R) XD 3-1 XM 4-8 DRMA 4 M 6-3 XD 3-1 XM 4-8 DRMA 5 W 116th St. W 116th St. Type 1 Req'd. Road Closure Sign Assembly, of Type III-B Barricades &12 Lft 120'120'120' Advance Signing Detail (1) M a tc h Lin e ( 1 ) XW 2 0 - 3 D RM A 1 D RMA 2 XW 2 0 - 2 Match Line (1) 120'120'120' XW 2 0 -3 XW 2 0 -2 D RMA 4 D RM A 3 M a t c h Lin e ( 4 ) Match Line (4) M a tc h Lin e ( 2 ) Advance Signing Detail (2) 1 D RM A 1 100' Advance Signing Detail (4) Ma tc h Lin e ( 3 ) D R MA 1 D RMA 6 DR M A 5 D RM A 5 D RMA 4 D RM A 3 DRMA 1 DRMA 2 DRMA 5 DR MA 6 DR M A 2 300' 300' 3 0 0 ' Lft. Road Closure Sign Assembly 5 Each Each Each 4 21Detour Route Marker Assembly Construction Sign, Type A QUANTITY SUMMARY - PHASE I Type III-A Barricade Construction Sign, Type C 5 Each SIDEWALK CLOSED (60" x 30") R11-3a Mod. (24" x 12") R9-9 1 Type III-B Barricade Lft. 3 3 3 (48" x 48") XW 20-3 (48" x 30") R 11-2 (60" x 30") R 11-4 ROAD CLOSED ROAD CLOSED TO THRU TRAFFIC DETOUR OR AFTER (DATE) RANGE LINE RD. CLOSED ON END DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Road Closure Sign Assembly, Type 2 (48"x18") XM 4-10 (L or R) 2 36 (60" x 30") R11-3a Mod. 4 116th ST. THRU TRAFFIC CONSIDER ALTERNATE ROUTE M a t c h Lin e ( 3 ) Advance Signing Detail (3) 1 D RM A 5 100' RANGE LINE ROAD SOUTH CLOSED TO THRU TRAFFIC W e s t fie ld Blv d . (60" x 30") R11-3a Mod. 5 RANGE LINE ROAD DETOUR TAKE NEXT EXIT Required 14 days prior to closure (60" X 36") XG20-5 144 Type 2 Req'd. (No Detour Sign) Road Closure Sign Assembly, 48 Lft of Type III-A Barricades & Type 2 Req'd. (No Detour Sign) Road Closure Sign Assembly, 24 Lft of Type III-A Barricades & Type 2 Req'd. (No Detour Sign) Road Closure Sign Assembly, 48 Lft of Type III-A Barricades & Type 1 Req'd. Road Closure Sign Assembly, 12 Lft of Type III-B Barricades & 12 Lft of Type III-B Barricades 6 (60" x 30") R11-3a Mod. MEDICAL DRIVE CLOSED AT RANGE LINE ROAD 6 DR M A 5 DR M A 5 DRMA 4 3 0 0 ' DRMA 3 Ma t c h Lin e ( 5 ) Advance Signing Detail (5) 7 D R MA 5 100' M a t ch Lin e ( 5 ) (60" x 30") R11-3a Mod. 7 RANGE LINE ROAD NORTH CLOSED TO THRU TRAFFIC Pedestrian Barricade Req'd. 6 Lft of Detectable 2 2 Construction Sign, Type B 14 Each Lft.42Detectable Pedestrian Barricade 18 Lft of Detectable Pedestrian Barricade Req'd. 18 Lft of Detectable Pedestrian Barricade Req'd. Medical Dr. W Carmel Dr.E Carmel Dr. 2 2 2 2 DETOUR DETOUR 109 99 9 9 10 10 10 10 (30" x 24") M4-9b (L) (30" x 24") M4-9b (R) Pedestrian Detour Route Type 2 Req'd. (No Detour Sign) Road Closure Sign Assembly, 24 Lft of Type III-A Barricades & Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways RANGE LINE ROAD - PHASE I DETOUR PLAN 1"=500' JABJAB NRM NRM N/A Lo u is v il l e a n d N a sh v il l e RR BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 9 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.DPL.01.dgn5/24/2021 09:42:50 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 3 5 4 0 Line "PR-S1A" Line "PR-S1A" RECKLESS DRIVING SPEEDING MAX $1000 MAX 6 YRS DAOR WORK DAEHA WORKSITE SPEED LIMIT 25 END ROAD WORK STOP 52 (78" X 42") XW2-6-A A B C D E F H (36" X 36") XW20-1 (36" X 36") W3-5 (24" X 36") R2-1 (24" X 18") XG20-5P (36" X 18") XG20-2A (36" X 36") W1-4 (L) 100'100'100' A B C D Advance Signing Detail (1) No Scale 100' M a t ch Lin e Ma tc h Lin e Ma tc h Lin e J H ONLY (30" X 36") R3-5(R) (30" X 30") R1-1 J F E K (36" x 36") W24-1(L) (36" x 36") W24-11(R) K L E 1'-0"11'-0"4'-0"11'-0"2'-0" Line "PR-S1A" Line "PR-S1A" 2'-0"1'-0"11'-0"11'-0" M (36" x 36") W4-2(R) (36" x 36") W4-2(R) 100' L or M 2 Not to Scale 32+60.00 "PR-S1A" to 37+28.00 "PR-S1A" Not to Scale 37+28.00 "PR-S1A" to 40+16.00 "PR-S1A" 1 2 1 1 1 ' 1 1 ' 1 1 ' 1 1 1 ' 1 1 ' 4 ' 2 2 2 x2 x2 2 1 2 1 x21 1 ' 1 1 ' 240' Merging Taper 100' Downstream Taper 200' Shifting Taper 240' Merging Taper See Advance Signing Detail (1) 32+80.00 "PR-S1A" BEGIN CONSTRUCTION + 2 6 + 7 5 + 7 6 M AT C H LIN E 1 - 3 7 + 7 8 "P R - S 1 A" MAT CH LI N E 1 - 3 7 + 7 8 "P R -S 1 A" + 2 8 Line "PR-RL1" 39+55.00 "PR-S1A" END CONSTRUCTION + 8 0 + 5 3 115' Shifting Taper + 5 2 R d . R a n g e Lin e 116th St. 116th St. 20'-0" (Typ) 175' Shifting Taper + 5 5 Standard Drum Tubular Marker Standard Drum + 9 0 24 Lft Type III-A Barricade Req'd 3 2 1 2 (24" x 24") R3-2 N N roundabout center island. straight concrete curb in Do not install roll curb or existing drainage pipe. Temporary connection to Owner prior to lane closure. under flagger operation with approval from the connection to exisitng manhole. To be constructed Temporary Lane Closure Req'd for storm pipe 1 24 Lft Type III-A Barricade Req'd See Advance Signing Detail (1) Phase II Construction Typical SectionPhase II Construction Typical Section Road - Phase II See Detour Plan Range Line Type III-A Barricades Req'd Flashing Arrow Sign See Sidewalk Detour Plan - Phase II Detectable Pedestiran Barricade Req'd See Sidewalk Detour Plan - Phase II Detectable Pedestiran Barricade Req'd - 116th Street CONSTRUCTION ZONE DESIGHT SPEED LIMIT = 25 MPH facilities at the same time along Range Line. - Contractor shall not close both east and west side pedestrian - 10' Minimum Lanes Shall be Maintained at all Times. noted. - Station and offset taken from Line PR-RL1 unless otherwise be maintained at all times. - Access to all businesses, residents, and roadways shall be NOTES: Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways 1"=30' N/A PHASE II MAINTENANCE OF TRAFFIC NRMNRM JAB JAB BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 10 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TP.01.dgn5/24/2021 09:42:54 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 836.0848344BRK Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways Line "PR-RL1" 2 1x2 Line "PR-RL1" Standard Drum Range Line Rd. Range Line Rd. 1 1 6 t h S tre e t 1 1 0 1 1 5 1 2 0 1 2 5 D r iv e M e d ic a l C a rm e l D riv e 10'-0" 1'-0" Varies10'-0" 1'-0" Varies Phase II Construction Area 1 Standard Drum Line "PR-RL1" 3 2 2 2 2 2 2 1 1 x21 0 ' 1 0 ' 20' (Typ .) 1 Not to Scale 116+80 "PR-RL1" to 124+50 "PR-RL1" 108+50 "PR-RL1" to 112+90 "PR-RL1" 1 1 1 1 2 x2 2 1 0 ' 1 0 ' 1 124+72 W4-2(R) (36" x 36") 12 LFT Type III-A Barricade Req'd Phase II Construction Area Phase II Construction Typical Section Constructed in Phase I Medical Drive Roundabout 2 80' Lane Shift Taper 1 1 '-0 " 1 5 ' - 0 " 15 '-0" 1 1 '-0 " + 4 5 1 1 2 1 0 ' 1 0 ' x21 1 '-0 " 1 1 '-0 " Lane Shift Taper 80'+ 0 0 2 1 W4-2(R) (36" x 36") Barricades Req'd. 6 LFT Detectable Pedestrian Barricades Req'd. 6 LFT Detectable Pedestrian Barricades Req'd. 6 LFT Detectable Pedestrian See Sidwalk Detour Plan - Phase II 6 LFT Detectable Pedestrian Barricades Req'd. See Sidewalk Detour Plan - Phase II 6 LFT Detectable Pedestrian Barricades Req'd. Barricades Req'd. 6 LFT Detectable Pedestrian 6 LFT Detectable Pedestrian Barricades Req'd. 6 LFT Detectable Pedestrian Barricades Req'd. 1 C a rm e l D riv e Range Line Rd.165' Merging Taper operation with approval from the Owner prior to lane closure. to proposed manhole. To be constructed under flagger Temporary Lane Closure Req'd. for storm pipe connection - 116th Street CONSTRUCTION ZONE DESIGHT SPEED LIMIT = 25 MPH facilities at the same time along Range Line. - Contractor shall not close both east and west side pedestrian - 10' Minimum Lanes Shall be Maintained at all Times. noted. - Station and offset taken from Line PR-RL1 unless otherwise be maintained at all times. - Access to all businesses, residents, and roadways shall be NOTES: Flashing Arrow Sign BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 11 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TP.01A.dgn5/24/2021 09:42:55 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 1"=30' N/A PHASE II MAINTENANCE OF TRAFFIC NRMNRM JAB JAB Ke ys t o n e P k w y . E 116th St. Medical Dr. maintained throughout the duration of the project. Access to all businesses and residential properties shall be NOTE: HA E E D DA S OR DA OLC DETOUR AHEAD Road Closure Sign Assembly, Type 1 (48"x18") XM 4-10 (L or R) (48" x 48") XW 20-2 W Carmel Dr.E Carmel Dr. XD 3-1 XM 4-8 XM 4-6 DRMA 6 M 6-1 (L) XD 3-1 XM 4-8 DRMA 1 M 5-1 (L) XD 3-1 XM 4-8 DRMA 2 M 6-1 (R) XD 3-1 XM 4-8 DRMA 3 M 5-1 (R) XD 3-1 XM 4-8 DRMA 4 M 6-3 XD 3-1 XM 4-8 DRMA 5 W 116th St. E 106th St.W 106th St. Type 2 Req'd. Road Closure Sign Assembly, 60 Lft of Type III-A Barricades & Type 1 Req'd. Road Closure Sign Assembly, of Type III-B Barricades &24 Lft 32+80.00 "PR-S1A" BEGIN CONSTRUCTION 38+60.00 "PR-S1A" END CONSTRUCTION 104+00.00 "PR-RL1" BEGIN PROJECT 120'120'120' Advance Signing Detail (1) M a t ch Lin e (1 ) XW 2 0 -3 DR MA 1 D R M A 2 XW 2 0 -2 Match Line (1) 120'120'120' XW 2 0 -3 XW 2 0 -2 D R M A 4 DR M A 3 M a t ch Lin e (4 ) Match Line (4) M a t ch Lin e (2 ) Advance Signing Detail (2) 1 DR MA 1 100' Advance Signing Detail (4) Ma tc h Lin e ( 3 ) D R M A 1 D RMA 1 DRMA 1 D RMA 6 DR M A 5 D RM A 5 D RMA 4 D RM A 3 DRMA 1 DRMA 2 DRMA 5 DRMA 5 DRMA 5 DRMA 5 DRMA 4 D RM A 2 DR M A 5 DR MA 5 D R M A 6 D R MA 6 D RM A 5 DRMA 2 DRMA 5 D RMA 2 DR MA 5 DRMA 33 0 0 ' 300' 300' 3 0 0 ' 1 0 0 0 ' Lft. Road Closure Sign Assembly 4 Each Line, Remove Lft. Each Each Each 16 36Detour Route Marker Assembly Construction Sign, Type B Construction Sign, Type A Type III-A Barricade Construction Sign, Type C 10 Each SIDEWALK CLOSED (60" x 30") R11-3a Mod. (24" x 12") R9-9 1 Type III-B Barricade Lft. 3 3 3 (48" x 48") XW 20-3 (48" x 30") R 11-2 (60" x 30") R 11-4 ROAD CLOSED ROAD CLOSED TO THRU TRAFFIC DETOUR OR AFTER (DATE) RANGE LINE RD. CLOSED ON END DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Road Closure Sign Assembly, Type 2 (48"x18") XM 4-10 (L or R) 2 36 3167 8125 Lft.Temporary Pavement Marking, Removable 4" (60" x 30") R11-3a Mod. 4 116th ST. THRU TRAFFIC CONSIDER ALTERNATE ROUTE 4 Ma t ch Lin e (2 ) M a t ch Lin e (3 ) Advance Signing Detail (3) 1 DR M A 5 100' 19 RANGE LINE ROAD SOUTH CLOSED TO THRU TRAFFIC W e s t fie ld Blv d . Type 2 Req'd. (No Detour Sign) Road Closure Sign Assembly, 48 Lft of Type III-A Barricades & DRMA 5 D RM A 5 4 5 of Exit Ramp Place at Beginning Note: (60" x 30") R11-3a Mod. 5 RANGE LINE ROAD DETOUR TAKE NEXT EXIT Required 14 days prior to closure (60" X 36") XG20-5 DRMA 3 1 0 0 0 ' 5 of Exit Ramp Place at Beginning Note: 1 0 0 0 ' Lft.14Temporary Pavement Marking, Removable 24" 156 Type 1 Req'd. Road Closure Sign Assembly, 12 Lft of Type III-B Barricades & 6 (60" x 30") R11-3a Mod. MEDICAL DRIVE CLOSED AT RANGE LINE ROAD TONHMA for Temporary Pavement, C 225 QUANTITY SUMMARY - PHASE II 45 DaysFlashing Arrow Sign C o ll e g e Av e . W e s t fie ld B lvd . DETOUR DETOUR 109 Lft.Detectable Pedestrian Barricade 66 (30" x 24") M4-9b (L) (30" x 24") M4-9b (R) 11 (24" x 18") R9-11 SIDEWALK CLOSED D C OSRS HERE AHEA M a t ch Lin e (4 ) Advance Signing Detail (5) 1 DR M A 3 100' Ma t ch Lin e (5 ) Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways RANGE LINE ROAD - PHASE II DETOUR PLAN 1"=500' JABJAB NRM NRM N/A Louisville and Nashville RR BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 12 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.DPL.02.dgn5/24/2021 09:42:57 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 E 116th St. Medical Dr. maintained throughout the duration of the project. Access to all businesses and residential properties shall be NOTE: E Carmel Dr. W e s t fie ld Blv d . W 116th St. W Carmel Dr. R a n g e li n g R d . Ke y sto n e P k w y . M o n o n T ra il DETOUR DETOUR Mon o n Trail Mo n o n T ra il (30" x 24") M4-9b (L) (30" x 24") M4-9b (R) 109 9 10 9 9 12 Lft of Detectable Pedestrian Barricade Req'd. 2 2 2 6 Lft of Detectable Pedestrian Barricade Req'd. AA A W a y (24" x 12") R9-9 SIDEWALK CLOSED 2 11 (24" x 18") R9-11 11 11 SIDEWALK CLOSED D C OSRS HERE AHEA Point South to Monon Trail Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways N/A JABJAB NRM NRM 1"=400' RANGE LINE ROAD - PHASE II SIDEWALK DETOUR PLAN BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 13 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.DPL.03.dgn5/24/2021 09:42:58 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 3 0 3 5 4 0 Line "PR-S1A" (78" X 42") XW2-6-A A B C D E F G H (36" X 36") XW20-1 (36" X 36") W3-5 (24" X 36") R2-1 (24" X 18") XG20-5P (36" X 18") XG20-2A (36" X 36") W1-4 (R) (36" X 36") XW20-3 100'100'100' A B C D Advance Signing Detail (1) No Scale 100' M a t ch Lin e H Advance Signing Detail (2) No Scale J (36" X 36") XW20-2 E J (36" x 36") W24-1(L) (36" x 36") W24-11(R) K L E Line "PR-S1A" 1'-0" 1'-6"12'-0"12'-0" Ma tc h Lin e A G M (36" x 36") W4-2(R) (36" x 36") W4-2(R) 100' 100' L or Not to Scale 36+90.00 "PR-S1A" to 39+55.00 "PR-S1A" 2 K F E Line "PR-RL1" 230' ShiftingTaper Varies Varies Ma tc h Lin e 1'-0" 10'-0"10'-0" 2 Varies Varies Line "PR-S1A" X2 1'-0" Not to Scale 32+68.00 "PR-S1A" to 35+75.00 "PR-S1A" 1 M 100'100'100' F 2 1 1 2 ' 1 2 ' 1 2 ' 12 '2 39+55.00 "PR-S1A" END CONSTRUCTION 104+00.00 "PR-RL1" BEGIN PROJECT See Advance Signing Detail (2) Lin e "P R -R L1 " M AT C H LI N E 1 - 3 9 + 0 4 " P R - S 1 A" MATCH LINE 2 - 106+84 "PR-RL1" MAT C H LI N E 1 - 3 9 + 0 4 "P R -S 1 A" M AT CH LI N E 2 - 1 0 6 + 8 4 " P R - R L1 " 116th St. 116th St. Westfield Blvd. R d . R a n g e Lin e Westfield Blvd . 116th St. 160' ShiftingTaper +69 2 2 1 24 Lft. Type III-A Barricades END ROAD WORK HA E E D DA S OR DA OLC DETOUR AHEAD RECKLESS DRIVING SPEEDING MAX $1000 MAX 6 YRS DAOR WORK DAEHA WORKSITE SPEED LIMIT 2552 N (24" X 24") R3-2 N 16 '-0" Temporary Pavement Constructed in Phase II 2x 2x ONLY (30" X 36") R3-5(R) O O Phase III-A Construction Typical SectionPhase III-A Construction Typical Section Road - Phase III See Detour Plan Range Line Type III-A Barricades Req'd Utilizing Roadway and Existing Drive for Fuel Truck Entry at All Times Contractor to Maintain Access for Barricades Req'd 48 LFT Type III-A Technical Provisions. for Fuel Truck Entry. See Construct Permanent Drive See Sidewalk Detour Plan - Phase III Detectable Pedestrian Barricades Req'd. - 116th Street CONSTRUCTION ZONE DESIGHT SPEED LIMIT = 25 MPH facilities at the same time along Range Line. - Contractor shall not close both east and west side pedestrian - 10' Minimum Lanes Shall be Maintained at all Times. noted. - Station and offset taken from Line PR-RL1 unless otherwise be maintained at all times. - Access to all businesses, residents, and roadways shall be NOTES: 240' Merging Taper 32+80.00 "PR-S1A" BEGIN CONSTRUCTION + 6 9 Ma t c h Lin e See Advance Signing Detail (1) 2 30'-0" (Typ .) 185' Shifting Taper + 6 9 24 Lft. Type III-A Barricades See Sidewalk Detour Plan - Phase III Detectable Pedestrian Barricades Req'd. 100' Downstream Taper + 8 3 240' Merging Taper 4 5 125'See Advance Signing Detail (1) Flashing Arrow Sign Ma tc h Lin e Barricades Req'd 60 LFT Type III-A Barricade Req'd. 6 LFT Detectable Pedestrian Line "PR-S1A" Flashing Arrow Sign Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways 1"=30' N/A JABJAB NRM NRM PHASE III-A MAINTENANCE OF TRAFFIC BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 14 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TP.02B.dgn5/24/2021 09:43:05 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Range Line Rd. 1 1 6 t h S tre e t 1 1 0 1 1 5 D r iv e M e d ic a l Road - Phase III See Detour Plan Range Line Type III-A Barricades Req'd Utilizing Temporary Aggregate for Fuel Truck Exit at All Times Contractor to Maintain Access for Barricades Req'd 60 LFT Type III-A Barricades Req'd 48 LFT Type III-A Technical Provisions. for Fuel Truck Exit. See Construct Permanent Drive - 116th Street CONSTRUCTION ZONE DESIGHT SPEED LIMIT = 25 MPH facilities at the same time along Range Line. - Contractor shall not close both east and west side pedestrian - 10' Minimum Lanes Shall be Maintained at all Times. noted. - Station and offset taken from Line PR-RL1 unless otherwise be maintained at all times. - Access to all businesses, residents, and roadways shall be NOTES: 6 LFT Detectable Pedestrian Barricades Req'd. 6 LFT Detectable Pedestrian Barricades Req'd. Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways 1"=30' N/A NRMNRM JAB JAB PHASE III-A MAINTENANCE OF TRAFFIC BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 15 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TP.02C.dgn5/24/2021 09:43:07 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 3 0 3 5 4 0 Line "PR-S1A" Line "PR-S1A" (78" X 42") XW2-6-A A B C D E F G H (36" X 36") XW20-1 (36" X 36") W3-5 (24" X 36") R2-1 (24" X 18") XG20-5P (36" X 18") XG20-2A (36" X 36") W1-4 (R) (36" X 36") XW20-3 100'100'100' A B C D Advance Signing Detail (1) No Scale 100' M a t ch Lin e H Advance Signing Detail (2) No Scale Ma t c h Lin e Ma tc h Lin e J (36" X 36") XW20-2 E J (36" x 36") W24-1(L) (36" x 36") W24-11(R) K L E Line "PR-S1A" 1'-0" 1'-6"12'-0"12'-0" Ma tc h Lin e A G M (36" x 36") W4-2(R) (36" x 36") W4-2(R) 100' 100' L or Not to Scale 36+90.00 "PR-S1A" to 39+55.00 "PR-S1A" 2 185' Shifting Taper K F E Line "PR-RL1" 240' Merging Taper 240' Merging Taper 230' ShiftingTaper Varies Varies Ma tc h Lin e 1'-0" 10'-0"10'-0" 2 Varies Varies Line "PR-S1A" X2 1'-0" Not to Scale 32+68.00 "PR-S1A" to 35+75.00 "PR-S1A" 1 M 100'100'100' F 4 5 2 1 1 2 ' 1 2 ' 1 2 ' 12 '2 See Advance Signing Detail (1) 32+80.00 "PR-S1A" BEGIN CONSTRUCTION 39+55.00 "PR-S1A" END CONSTRUCTION 104+00.00 "PR-RL1" BEGIN PROJECT See Advance Signing Detail (2) Lin e "P R -R L1 " M AT C H LI N E 1 - 3 9 + 0 4 " P R - S 1 A" MATCH LINE 2 - 106+84 "PR-RL1" MAT C H LI N E 1 - 3 9 + 0 4 "P R -S 1 A" + 6 9 + 6 9 M AT CH LI N E 2 - 1 0 6 + 8 4 " P R - R L1 " 100' Downstream Taper + 8 3 116th St. 116th St. Westfield Blvd. R d . R a n g e Lin e Westfield Blvd . 116th St. 160' ShiftingTaper 125' +69 2 2 30'-0" (Typ .) 2 1 24 Lft. Type III-A Barricades END ROAD WORK HA E E D DA S OR DA OLC DETOUR AHEAD RECKLESS DRIVING SPEEDING MAX $1000 MAX 6 YRS DAOR WORK DAEHA WORKSITE SPEED LIMIT 2552 N (24" X 24") R3-2 N 16 '-0" Temporary Pavement Constructed in Phase II 2x 2x ONLY (30" X 36") R3-5(R) O O See Advance Signing Detail (1) Flashing Arrow Sign Flashing Arrow Sign Phase III-B Construction Typical SectionPhase III-B Construction Typical Section 24 LFT Type III-A Barricades Req'd for Fuel Truck Entry at All Times Contractor to Maintain Access for Road - Phase III See Detour Plan Range Line Type III-A Barricades Req'd See Sidewalk Detour Plan - Phase III Detectable Pedestrian Barricades Req'd. See Sidewalk Detour Plan - Phase III Detectable Pedestrian Barricades Req'd. - 116th Street CONSTRUCTION ZONE DESIGHT SPEED LIMIT = 25 MPH facilities at the same time along Range Line. - Contractor shall not close both east and west side pedestrian - 10' Minimum Lanes Shall be Maintained at all Times. noted. - Station and offset taken from Line PR-RL1 unless otherwise be maintained at all times. - Access to all businesses, residents, and roadways shall be NOTES: Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways 1"=30' N/A JABJAB NRM NRM PHASE III-B MAINTENANCE OF TRAFFIC BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 16 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TP.02.dgn5/24/2021 09:43:08 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 FP 836.0848344BRK Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways Range Line Rd. Range Line Rd. 1 1 6 t h S tre e t 1 1 0 1 1 5 1 2 0 1 2 5 D r iv e M e d ic a l C a rm e l D riv e Standard Drum 1'-0" Varies Not to Scale 116+80 "PR-RL1" to 121+90 "PR-RL1" 109+65 "PR-RL1" to 112+90 "PR-RL1" W4-2(L) (36" x 36") 124+85 1 0 ' 1 0 ' 1 0 ' 1 0 'Line "PR-RL1" 2 2 2 2 2 2 2 2 1 0 ' 1 0 ' 1 0 ' 1 0 ' (Typ.)20' 10'-0" 2 Line "PR-RL1" 1'-0" 10'-0" 2 2 ONLY (30" X 36") R3-5(R) A A A AA A AA A A AA 12 Lft. Type III-B Barricades Req'd DO NOT ENTER (30" X 30") R5-1 B B Road - Phase III See Detour Plan Range Line Type III-A Barricades Req'd Road - Phase III See Detour Plan Range Line Type III-A Barricades Req'd 1 6 '- 0 " 16'-0"16 '-0" 16 '-0" Phase III-B Construction Typical Section Phase III-B Construction Area for Fuel Truck Exit at All Times Contractor to Maintain Access for A A A A (Typ.)20'(Typ.)20' (Typ.)20' 12 LFT Type III-B Barricade Req'd - 116th Street CONSTRUCTION ZONE DESIGHT SPEED LIMIT = 25 MPH facilities at the same time along Range Line. - Contractor shall not close both east and west side pedestrian - 10' Minimum Lanes Shall be Maintained at all Times. noted. - Station and offset taken from Line PR-RL1 unless otherwise be maintained at all times. - Access to all businesses, residents, and roadways shall be NOTES: 165' Merging Taper C a rm e l D riv e Range Line Rd. W4-2(R) (36" x 36") (Placed in Median) 6 LFT Detectable Pedestrian Barricades Req'd. 6 LFT Detectable Pedestrian Barricades Req'd. 6 LFT Detectable Pedestrian Barricades Req'd. 6 LFT Detectable Pedestrian Barricades Req'd. (Placed in Median) Flashing Arrow Sign BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 17 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TP.02A.dgn5/24/2021 09:43:09 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 1"=30' N/A NRMNRM JAB JAB PHASE III-B MAINTENANCE OF TRAFFIC Ke ys t o n e P k w y . E 116th St. Medical Dr. maintained throughout the duration of the project. Access to all businesses and residential properties shall be NOTE: HA E E D DA S OR DA OLC DETOUR AHEAD Road Closure Sign Assembly, Type 1 (48" x 48") XW 20-2 W Carmel Dr.E Carmel Dr. XD 3-1 XM 4-8 XM 4-6 DRMA 6 M 6-1 (L) XD 3-1 XM 4-8 DRMA 1 M 5-1 (L) XD 3-1 XM 4-8 DRMA 2 M 6-1 (R) XD 3-1 XM 4-8 DRMA 3 M 5-1 (R) XD 3-1 XM 4-8 DRMA 4 M 6-3 XD 3-1 XM 4-8 DRMA 5 W 116th St. E 106th St.W 106th St. Type 2 Req'd. Road Closure Sign Assembly, 24 Lft of Type III-A Barricades & Type 1 Req'd. Road Closure Sign Assembly, of Type III-B Barricades &12 Lft 32+80.00 "PR-S1A" BEGIN CONSTRUCTION 38+60.00 "PR-S1A" END CONSTRUCTION 104+00.00 "PR-RL1" BEGIN PROJECT 120'120'120' Advance Signing Detail (1) Ma t c h Lin e (1 ) XW 2 0 -3 D R MA 1 DR M A 2 XW 2 0 -2 Match Line (1) 120'120'120' XW 2 0 -3 XW 2 0 -2 D R M A 4 D R MA 3 Ma t c h Lin e (4 ) Match Line (4) Ma t c h Lin e (2 ) Advance Signing Detail (2) 1 DR MA 3 100' Advance Signing Detail (4) D R M A 1 D RMA 6 DR M A 5 D RM A 5 D RMA 4 D RM A 3 DRMA 1 DRMA 2 DRMA 5 DRMA 5 DRMA 5 DRMA 5 D RM A 2 DR M A 5 DR MA 5 D R M A 6 D R M A 4 300' 300' 3 0 0 ' Lft. Road Closure Sign Assembly 4 Each Line, Remove Lft. 40 Each Each Each 21 35Detour Route Marker Assembly Construction Sign, Type B Construction Sign, Type A Type III-A Barricade Construction Sign, Type C 11 Each SIDEWALK CLOSED (24" x 12") R9-9 1 Type III-B Barricade Lft. 3 3 (48" x 48") XW 20-3 (48" x 30") R 11-2 (60" x 30") R 11-4 ROAD CLOSED ROAD CLOSED TO THRU TRAFFIC DETOUR OR AFTER (DATE) RANGE LINE RD. CLOSED ON END DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Range Line Rd. DETOUR Road Closure Sign Assembly, Type 2 3 24 175 7430 Lft.Temporary Pavement Marking, Removable 4" 300' DR M A 2 D R MA 1 Ma tc h Lin e ( 3 ) Advance Signing Detail (3) D RMA 5 100' M a t c h Lin e ( 3 ) (60" x 30") R11-3a Mod. 2 RANGE LINE ROAD NORTH CLOSED TO THRU TRAFFIC DR M A 3 DRMA 4 3 0 0 ' DRMA 3 D RM A 6 D R MA 5 D RM A 5 D R M A 5 M a t ch Lin e (2 ) 1 (60" x 30") R11-3a Mod. 116TH ST. THRU TRAFFIC CONSIDER ALTERNATE ROUTE 4 4 4 Required 14 days prior to closure (60" x 36") XG20-5 5 (60" x 30") R11-3a Mod. RANGE LINE ROAD DETOUR TAKE NEXT EXIT W e s t fie ld Blv d . of Exit Ramp Place at Beginning Note: DRMA 3 1 0 0 0 ' DRMA 4 1 0 0 0 ' 5 5 1 0 0 0 ' DRMA 3 of Exit Ramp Place at Beginning Note: Type 2 Req'd. (No Detour Sign) Road Closure Sign Assembly, of Type III-A Barricades &24 Lft Type 2 Req'd. (No Detour Sign) Road Closure Sign Assembly, of Type III-A Barricades &24 Lft 228 QUANTITY SUMMARY - PHASE III TONCompacted Agg. No. 53 Temp. for Driveways 90 Days60Flashing Arrow Sign G u il f o rd R o a d Lft.36Detectable Pedestrian Barricade (48" x 18") XM 4-10 (L or R) (48" x 18") XM 4-10 (L or R) DETOUR DETOUR 109 11 (24" x 18") R9-11 SIDEWALK CLOSED D C OSRS HERE AHEA Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways 1"=500' JAB NRMNRM JAB N/A RANGE LINE ROAD - PHASE III DETOUR PLAN Lo u is v il l e a n d N a sh v il l e RR BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 18 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.DPL.04.dgn5/24/2021 09:43:10 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 E 116th St. Medical Dr. maintained throughout the duration of the project. Access to all businesses and residential properties shall be NOTE: E Carmel Dr. W e s t fie ld Blv d . W 116th St. W Carmel Dr. R a n g e li n g R d . Ke y sto n e P k w y . M o n o n T ra il Mon o n Trail Mo n o n T ra il 9 10 10 109 11 12 Lft of Detectable Pedestrian Barricade Req'd. 9 10 10 11 DETOUR DETOUR (30" x 24") M4-9b (L) (30" x 24") M4-9b (R) 109 (24" x 12") R9-9 SIDEWALK CLOSED 2 11 (24" x 18") R9-11 SIDEWALK CLOSED D C OSRS HERE AHEA 2 2 2 AA A W a y Point South to Monon Trail 11 Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways N/A JABJAB NRM NRM 1"=400' RANGE LINE ROAD - PHASE III SIDEWALK DETOUR PLAN BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 19 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.DPL.05.dgn5/24/2021 09:43:11 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 (36" x 36") W4-2(R) (36" X 36") XW20-1 DAOR WORK DAEHA (78" X 42") XW2-6-A RECKLESS DRIVING SPEEDING MAX $1000 MAX 6 YRS (36" X 36") W3-5 (24" X 36") R2-1 (24" X 18") XG20-5P SPEED LIM IT 25 (36" X 18") XG20-2A END ROAD WORK WORKSITE Ma t c h Lin e 100'100'100'100'100' No Scale 52 FED CBA A B C D F 12 Each Each Lft. 12 Construction Sign, Type B Construction Sign, Type A 2 2 2 2 See Advance Signing Detail Advance Signing Detail S e e Ad v a n c e S ig n in g D e ta il See Advance Signing Detail S e e Ad v a n c e Sig n in g D e ta il E E E E 2 15'-0" 240' Merging Taper 240' Merging Taper 1 1 5 ' M e rg in g Ta p e r 1 2 ' 12' 1 2 ' 10' Temporary Pavement Marking, Removable 4 IN 2000 Match Line M a tc h Lin e Match Line M a t ch Lin e QUANTITY SUMMARY - PHASE IV Each4 Flashing Arrow Sign Flashing Arrow Sign Flashing Arrow Sign 116th Street R a n g e Lin e R o a d Days45Flashing Arrow Sign Construction Sign, Type C - 116th Street CONSTRUCTION ZONE DESIGHT SPEED LIMIT = 25 MPH facilities at the same time along Range Line. - Contractor shall not close both east and west side pedestrian - 10' Minimum Lanes Shall be Maintained at all Times. noted. - Station and offset taken from Line PR-RL1 unless otherwise be maintained at all times. - Access to all businesses, residents, and roadways shall be NOTES: A/C A/C A/C A/C MON EM EM GM PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST IPn MB MB MAG MAG MAG MON MON MON MON MON MON MON MON W W W W W W W W PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST RB-0 TT T C MON PPST FFE PPST GM GM MBFFE FFE FFE FFE PPST PPST PPST PPST MB PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST MB PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST FFE PPST MON EM FFE FFE PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST TT EM MON MON PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST EM EM EM EM GM PPST PPST GM GM FFEA/C FFE PPST TF EM FFE EM EM EM EM PPST FFE FFE PPST PPST GM PPST EM EM EM EM EM EM EM EMFFE PPST MAG MAG MAG G H B PZZZ H BG G A/C PPST PPST PPST G PF FP Construction Area Direction of Traffic Type III-A or III-B Barricade LEGEND Type "A" Construction Warning Light Type "B" Construction Warning Light 1 2 Line, Remove Detour Route Standard Drum Tubular Marker Construction Sign, Type A or Type B 3 Temp. Pavement Marking, Removable, 4 in., White Temp. Pavement Marking, Removable, 4 in., Yellow Temp. Pavement Marking, Removable, 24 in., White, Stop Bar HMA for Temporary Pavement, C Compacted Aggregate No. 53 Temporary for Driveways JAB RJC NRMNRM 1" = 500' N/A PHASE IV MAINTENANCE OF TRAFFIC BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 20 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.TP.03.dgn5/24/2021 09:43:18 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 A/C A/C A/C A/C MON LD LDLD LD LD EM EM EM EME GM PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST MB MAG MAG MAG MON MON MON MON MON MON MON MON MON MON W W W W W W W W W W W W W W W W PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST RB-0 RB-0 TT T H H H H H H H H H H CC-TR C WV WV WV WV WV FFE FFE PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST FFE PPST CC-TR T H WV C WV H T H MON EM WV FFE FFE PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST T T EM MON PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST EM EM EM EM GM PPST PPST GM GM PPST WV RB-0 MAG MAG RB-0 G H B PZZZ H H H H H BG G 12" rcp 4" pvc 42 " rcp 12" rcp 1 2 " rcp 1 2 " cp p 12 " rc p 12" rcp 12" rcp 12 " rcp 8" pv c 8" pvc 8" pvc30 " rcp 12" rcp 6" pvc30" rcp 12" rcp 8" pvc12" rcp 12 " cpp 12" cmp 21 " rcp 1 2 " cp p 12 " cpp 12" cpp 12 " rcp 12 " rcp 12" rcp 12 " rcp 12 " rcp 12 " rcp 12 " rcp 4 2" rc p 12" rcp 21" rcp 12" rcp 18" rcp 42 " rcp 12" rcp 12" rcp 42" rcp 12" rcp 12" rcp 12" rcp T 42" rcp 48" rcp G PF F P 2 Inlets & 118 Lft. Pipe, Remove 157 Lft. Conc. Curb & Gutter, Remove 70 Lft. Conc. Curb & Gutter, Remove339 Lft. Conc. Curb & Gutter, Remove 118 Lft. Conc. Curb & Gutter, Remove 425 Lft. Conc. Curb & Gutter, Remove 235 Lft. Conc. Curb, Remove Inlet & 60 Lft. Pipe, Remove Inlet, Manhole, & 20 Lft. Pipe, Remove Inlet & 58 Lft. Pipe, Remove Inlet & 26 Lft. Pipe, Remove 29 Sys Conc. Sidewalk, Remove 19 Sys Conc. Sidewalk, Remove 71 Sys. Conc. Sidewalk, Remove 78 Sys. Conc. Sidewalk, Remove 29 Sys. Conc. Sidewalk, Remove 37 Sys. Conc. Sidewalk, Remove 33 Sys. Conc. Sidewalk, Remove 21 Sys. Conc. Sidewalk, Remove 47 Sys. Conc. Sidewalk, Remove 162 Sys. Conc. Sidewalk, Remove 62 Sys. Conc. Sidewalk, Remove 29 Sys. Conc. Sidewalk, RemoveTraffic Signal & Foundation, Remove Traffic Signal & Foundation, Remove Traffic Signal & Foundation, Remove Traffic Signal & Foundation, Remove Traffic Controller & Foundation, Remove Line "PR-S1A" Lin e "P R- R L1 " W e s t fie ld Blv d . R a n g e Lin e R d . 116th St. 116th St. Ap p . P. L. Ap p . P . L. Ap p . Exis t. R / W T e m p R / W R / W App. Exist. R/W App. Exist. R/W R/W Temp. R/W Ap p . E xist. R / W App. Exist. R/W T e m p . R/ W Temp. R/W R/W App. Exist. R/W Ap p . E x is t . R/ W Ap p . P.L. Te m p R/ W 106 Lft. Conc. Curb & Gutter, Remove Inlet, Manhole, & 20 Lft. Pipe, Remove 33 Sys. Conc. Sidewalk, Remove 86 Sys. Conc. Sidewalk, Remove 69 Sys. Conc. Sidewalk, Remove 169 Lft. Conc. Curb & Gutter, Remove 127 Lft. Conc. Curb & Gutter, Remove 126 Lft. Conc. Curb & Gutter, Remove 143 Lft. Conc. Curb & Gutter, Remove 2 Inlets & 88 Lft. Pipe, Remove Pipe, Remove Inlet, Manhole & 26 Lft. 65 Lft. Conc. Curb, Remove 72 Lft. Conc. Curb & Gutter, Remove 71 Lft. Conc. Curb, Remove 89 Lft. Conc. Curb & Gutter, Remove 60 Lft. Conc. Curb, Remove 51 Lft. Conc. Curb & Gutter, Remove 27 Sys. Conc. Sidewalk, Remove 68 Lft. Conc. Curb & Gutter, Remove 31 Sys. Conc. Sidewalk, Remove Ap p . P .L. R/W R/W R/W 20 Lft. Conc. Curb, Remove 28 Sys. Asphalt, Remove 67 Sys. Conc. Remove 51 Sys. Conc. Remove 88 Sys. Conc. Remove 67 Sys. Conc. Remove 44 Sys. Conc. Remove 50 Sys. Conc. Remove 46 Sys. Conc. Remove 54 Sys. Conc. Remove 58 Sys. Conc. Remove 46 Sys. Conc. Remove South Drive at Station 106+17 108 Sys. Conc. Remove on 43 Sys. Conc. Remove & BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 21 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.REMOVAL.01.dgn5/24/2021 09:43:19 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 INTERSECTION REMOVAL DETAILS 1" = 30' N/A EAK NRMNRM JAB LD LD LD LD H H H H PP ST PP S T PP S T PP S T MAG MON MON MO N MON PP ST PP S T PP S T T T H H H CC -TR C WM WM WV W V WV WV W V WV WV WV RB-0 H B PZZ Z PZZ Z PZZZ PZZ Z PZZZ PZZ Z H H H MON H PP S T PPST T WV PP ST PPST PPST PPST LD H C W V G H B PZZZ PZZZ 24 " rcp 12" pvc to 12" cpp(verified) 21" rcp 30 " rcp 12" cpp 12" rcp 12" rcp 8" c pp 24 " cpp 12" rcp 12" cpp 12" rcp12" rcp12" rcp 8" cpp 12" rcp 42" rcp 36" rcp 1 2 " rcp 36" rcp 36" rcp 12" cpp 12 " rcp 36" rcp 36" rcp 12" rcp 12" rcp 18" cpp 12" rcp 12" rcp 4" cpp MON MON MON MON PP S T PP ST PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T 30 " rcp 30" rcp F P 836.0848344BRK Line "PR-RL1" Range Line Rd. App. Exist. R/W Temp R/W Temp R/W M e d ic a l D r. App. Exist. R/W Ap p . P .L. Ap p . P .L. Ap p . P .L. Ap p . P .L. Ap p . P.L. Ap p . P.L. Ap p . P .L. Temp. R/W Temp. R/W App. Exist. R/W Temp. R/W Temp. R/W App. Exist. R/W Temp. R/W R/W Ap p . Exis t. R /W R/W Temp. R/W Ap p . Exis t. R / W Lin e "PR -S 2 A" Lin e " S- 2 -A" App. Exist. R/W T e m p . R/ W 184 Sys. Conc. Sidewalk, Remove 466 Lft. Conc. Curb & Gutter, Remove 184 Lft. Conc. Curb & Gutter, Remove 60 Lft. Paved Side Ditch, Removal 83 Sys. Conc. Sidewalk, Remove Traffic Signal & Foundation, Remove Traffic Controller & Foundation, Remove Traffic Signal & Foundation, Remove Traffic Signal & Foundation, Remove Traffic Signal & Foundation, Remove 155 Lft. Conc. Curb & Gutter, Remove 324 Lft. Conc. Curb & Gutter, Remove 157 Sys. Conc. Sidewalk, Remove 380 Lft. Conc. Curb & Gutter, Remove 79 Lft. Conc. Curb & Gutter, Remove 100 Sys. Conc. Sidewalk, Remove144 Sys. Conc. Sidewalk, Remove 25 Sys. Conc. Sidewalk, Remove 64 Sys. Conc. Sidewalk, Remove 130 Lft. Conc. Curb & Gutter, Remove 95 Lft. Conc. Curb & Gutter, Remove 61 Sys. Conc. Sidewalk, Remove 476 Lft. Conc. Curb & Gutter, Remove 197 Sys. Conc. Sidewalk, Remove 190 Lft. Conc. Curb & Gutter, Remove 79 Sys. Conc. Sidewalk, Remove 86 Lft. Conc. Curb & Gutter, Remove Temp. R/W App. P.L. 78 Sys. Conc. Remove 71 Sys. Conc. Remove 86 Sys. Conc. Remove 52 Sys. Conc. Remove 50 Sys. Conc. Remove46 Sys. Conc. Remove 32 Sys. Conc. Remove 71 Sys. Conc. Remove BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 22 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.REMOVAL.02.dgn5/24/2021 09:43:20 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 INTERSECTION REMOVAL DETAILS 1" = 30' N/A NRMNRM EAKJAB T C WM H C MON G G 12 " rcp 12" rcp 36" rcp 4" cpp 12" rcp 12 " rcp 12 " rcp 12 " rcp 4" cpp W V H WV WV H H H H T MON H H FP H H H H PP S T PP S T TR 15" hdpe 15" hdpe 6" pv c 36" rcp 12 " rcp 12" hdpe 1 2 " h d p e 36" rcp 15" hdpe 12 " rcp 12 " rcp 42 " rcp 36" rcp 1 2 " r c p 1 5 " h d p e 15" hdpe 15 " pv c 1 5 " h d p e 12 " rcp 12 " rcp 1 2 " r c p H W V WV WV W V 36" rcp Range Line Rd. Ap p . P.L. Ap p . P .L. Temp. R/W 61 Lft. Conc. Curb & Gutter, Remove 15 Sys. Conc. Sidewalk, Remove Ap p . P.L. Ap p . P .L. Ap p . P .L. Line "PR-RL1" App. Exist. R/W C a r m e l D r . App. Exist. R/W App. Exist. R/W Ap p . E x is t . R/ W Ap p . Exis t. R / W Ap p . P .L. Ap p . E x is t . R/ W App. Exist. R/W App. Exist. R/W Ap p . E x is t . R/ W Ap p . Exis t. R / W Temp. R/W 49 Lft. Conc. Curb & Gutter, Remove 44 Lft. Conc. Curb & Gutter, Remove 78 Sys. Conc. Sidewalk, Remove 160 Lft. Conc. Curb & Gutter, Remove 66 Lft. Conc. Curb & Gutter, Remove 57 Lft. Conc. Curb & Gutter, Remove 35 Lft. Conc. Curb & Gutter, Remove 26 Lft. Conc. Curb & Gutter, Remove 65 Lft. Conc. Curb & Gutter, Remove 80 Sys. Conc. Sidewalk, Remove 180 Lft. Conc. Curb & Gutter, Remove 57 Lft. Conc. Curb & Gutter, Remove 61 Lft. Conc. Curb & Gutter, Remove 164 Sys. Conc. Sidewalk, Remove 60 Lft. Conc. Curb & Gutter, Remove 19 Sys. Conc. Sidewalk, Remove 45 Lft. Conc. Curb & Gutter, Remove 15 Sys. Conc. Sidewalk, Remove 48 Sys. Conc. Sidewalk, Remove & Gutter, Remove 118 Lft. Conc. Curb App. Exist. R/W Sidewalk, Remove 22 Sys. Conc. & Gutter, Remove 60 Lft. Conc. Curb 7 Sys. Conc. Sidewalk, Remove 86 Sys. Conc. Remove 56 Sys. Conc. Remove 29 Sys. Conc. Remove 30 Sys. Conc. Remove 70 Sys. Conc. Remove 54 Sys. Conc. Remove 65 Sys. Conc. Remove 59 Sys. Conc. Remove BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 23 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.REMOVAL.03.dgn5/24/2021 09:43:21 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 INTERSECTION REMOVAL DETAILS 1" = 30' N/A NRMNRM EAKJAB SPEEDWAY LLC 1 1 6 t h S t . 2 0 + 0 0 No Curve Run �=0°01'27" RT. P.I. 20+00.00 "S-1-A" No Curve Run �=1°36'10" LT. P.I. 20+00.00 "RL" = HAMILTON COUNTY CLAY TOWNSHIP SEC. 6, T 17 N, R 4 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 1, T 17 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E For Proposed Drainage Structures, see Construction Details. All Topography Information Described from Line "RL", Except as Noted. Line "PR-RL1" to be Constructed. All R/W Described from Line "PR-RL1", Except as Shown. NOTES: (gas pumps) (1-sty block gas station) con c. conc. con c. con c. conc. conc. conc. conc. conc. conc. con c. conc. conc. conc. conc. gra s s gra s s grass grass grass grass grass grass grass grass grass grass grass grass grass grass grass grass grass gra s s ston e woods woods woods asph alt asph alt a s ph alt asphalt asphalt asphalt a s ph a lt ripra p riprap plante r planter pla nter planter plante r plante r pla nte r pla nter pla nter pla nter grass grass riprap 2" pvc 6" pvc 1 2 " r c p 4" pv c 12" rcp 12" rcp 12" rcp conc. O/H Canopy asphalt asphalt con c. as ph alt con c. asphalt asphalt asphalt asphalt asphalt conc. conc. conc. (brick Walgreens) 42" rcp 18" rcp 12" rcp 12" rcp 42" rcp 42" rcp42" rcp 12" rcp 21" rcp 192" cmp 12" rcp conc. (1-sty brick/frame) conc. 21" rcp 6" vcp 8" vcp KRG CENTRE LLC CORNER ASSOCIATES LP ASSOCIATION INC HOMEOWNERS CREEKSIDE Common Area A GRAHAME D. & DIANA J. CURTS Replat - Block A Creekside ASSOCIATION INC HOMEOWNERS CREEKSIDE Ap p . P.L. App. P.L.App. P.L. App. Section Line Ap p . Ex is t . R / W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W Ap p . E x is t. R/ W Ap p . Ex is t . R / W App. Exist. R/W (1-sty brick) App. P.L. 12 +63 .4, 43 .3', Tre e +83 .4, 29 .6', Ha nd h o le +83 .5, 29 .2', Ha nd h o le +85 .9, 23 .0', Mail bo x +90 .9, 33 .5', Te le. Pole +94 .6, 46 .6', Pine Tre e +97 .9, 78 .5', Pine Tre e 13 +25 .4, 65 .1', Tre e +32 .2, 20 .6', Te le. Manh o le +37 .7, 76 .8', Pine Tre e +46 .0, 21 .1', Mag Na il +95 .6, 79 .2', Tre e +99 .2, 45 .4', Rebar Fou n d 14 +08 .7, 36 .4', Mon u m ent 14 +18 .0, 89 .8', Tre e +36 .4, 71 .4', Tre e +42 .9, 33 .5', Te le. Pole +50 .4, 60 .8', Tre e +67 .6, 53 .0', Tre e +87 .4, 47 .1', Re ba r Fou n d +92 .2, 31 .6', Mon u ment 15 +00 .1, 77 .0', Mag Na il +46 .1, 41 .8', Tre e +77 .2, 41 .8', Tre e 15 +79 .3, 34 .4', Ha nd h o le 16 +00 .4, 33 .9', Mon u m ent 16 +00 .8, 34 .1', Te le. Pole +22 .9, 66 .9', Mon u ment +29 .6, 57 .0', Sign +29 .6, 45 .0', Sign +36 .3, 43 .3', Sign +56 .6, 26 .1', Inlet +74 .9, 28 .7', S ign +84 .6, 42 .8', Fire Hyd rant +84 .9, 39 .8', Wa te r Va lve +88 .2, 47 .4', Mail bo x +96 .0, 32 .2', Mon u ment +98 .8, 32 .0', Inle t 17 +60 .8, 32 .8', S ign 17 +62 .8, 44 .1', Rebar Fou n d +65 .7, 35 .6', Mon u ment +68 .8, 34 .2', Te le. Pole +69 .3, 43 .8', Ha nd h o le +73 .2, 81 .2', Well +74 .0, 43 .2', Wa te r Va lve +83 .5, 40 .4', Sign +92 .8, 34 .2', S ign +99 .0, 34 .1', Ha nd h o le +99 .8, 47 .8', Sign 18 +01 .9, 92 .2', Tre e 18 +01 .9, 43 .6', Ha nd h o le +04 .5, 57 .0', S ign +05 .2, 47 .7', S ign +42 .3, 75 .4', Well +47 .7, 42 .3', Ligh t P ole +47 .8, 75 .4', Misc. MH +48 .5, 46 .4', Sign +50 .2, 31 .8', Inlet +51 .8, 96 .6', Grou n d Ligh t +64 .6, 50 .0', Well +68 .0, 97 .1', S prink le r Con trol Va lve +69 .1, 55 .7', Misc. MH +71 .1, 32 .6', Te le. Manh o le +71 .4, 42 .5', Ligh t Pole +73 .6, 46 .6', Well +76 .0, 55 .4', Well +76 .6, 34 .2', Ligh t P ole +79 .2, 48 .7', Well +80 .2, 46 .5', Ligh t Pole +82 .2, 47 .9', S prink le r Con trol Va lve +82 .5, 97 .1', Grou n d Ligh t +83 .3, 34 .0', Ha nd h o le 19 +04 .5, 63 .2', We ll +09 .5, 67 .0', Misc. MH +11 .7, 76 .8', Misc. MH +12 .0, 93 .4', Pos t +14 .6, 91 .8', P ost +15 .6, 68 .1', Misc. MH +23 .8, 77 .3', Misc. MH +24 .2, 91 .8', P ost +26 .0, 47 .6', Well +26 .9, 93 .4', P ost 19 +29 .9, 45 .3', Rebar Fou n d +32 .7, 53 .7', Ligh t P ole +34 .7, 78 .3', Misc. MH +34 .8, 59 .3', P ost +37 .7, 82 .7', Well +39 .3, 52 .2', Ha nd h o le +41 .4, 53 .6', CATV P ede s ta l +41 .8, 87 .6', Well +44 .0, 54 .7', Traff ic Strain Pole +44 .6, 53 .4', Traff ic S train Pole +45 .1, 47 .7', Wa te r Va lve +48 .8, 47 .6', Mon u ment +50 .7, 73 .1', Ligh t P ole +50 .9, 61 .3', Wa te r Va lve +51 .2, 63 .6', Fire Hyd rant +52 .0, 93 .4', Guy Wire +52 .3, 76 .8', Com binati on Pole +52 .8, 66 .7', Ha nd h o le +54 .1, 72 .6', Tele . P ede s ta l +54 .3, 70 .5', Com binati on Pole +55 .9, 76 .6', Tra ff ic P ede s ta l +64 .4, 68 .0', Ha nd h o le +65 .2, 77 .5', Ha nd h o le +66 .5, 82 .2', Inle t +66 .6, 82 .4', Clea no u t +72 .4, 36 .0', Te le. Manh o le +72 .9, 30 .4', Te le. Manh o le +93 .8, 73 .4', Detec tor Hou sing 20 +04 .1, 73 .0', De te c tor Hou s ing +22 .8, 13 .4', Drainage Manh o le 20 +26 .0, 83 .3', Drainage Manh o le +33 .1, 81 .4', Inle t +34 .3, 76 .6', Ha nd h o le +39 .6, 46 .0', Drainage Manh o le +44 .9, 75 .8', Ha nd h o le +49 .2, 60 .6', Ha nd h o le +50 .8, 78 .9', Wa te r Va lve +52 .0, 82 .7', Re ba r Fou n d +54 .8, 54 .8', Traff ic Strain Pole +57 .0, 44 .5', Mon u ment +57 .7, 84 .3', G as Va lve +58 .1, 81 .7', Gas Line Ma rker +58 .8, 55 .8', Ha nd h o le +60 .8, 47 .3', Mon u ment +61 .6, 61 .6', Ha nd h o le +66 .1, 53 .6', Traff ic S train Pole +66 .7, 75 .2', Well +71 .5, 86 .0', Gas Line Meter +72 .1, 16 .1', Drainage Manh o le +72 .7, 50 .6', Traff ic P edestal +73 .4, 31 .1', Gas Valve +74 .4, 61 .5', Wa te r Va lve +75 .0, 66 .1', Fire Plug +78 .9, 48 .7', Ha nd h o le +87 .2, 34 .6', P ost +90 .0, 50 .0', Re ba r Fou n d +91 .5, 32 .0', Inlet +91 .9, 53 .3', Ligh t P ole +99 .9, 68 .7', Inlet +51 .7, 41 .8', Drainage Mh. Ap p . E x is t . R/ W Ap p . S e c ti o n Lin e 820 810 800 840 830 C ar m el C k. Flo w (NAVD 88) (TBM#51) 70' R/W Rangeline Rd. at NW side of Carmel Creek El. 812.55 TBM #51 - Chisled "□" on Conc. Hdwl. of 21"rcp 59'± W of � CURVE DATA P.I. = 106+87.87 "PR-RL1" T = 26.35' R = 333.00' E = 1.04' S.E. = N.C. L = 52.60' CURVE DATA P.I. = 108+56.97 "PR-RL1" T = 66.69' L = 131.64' R = 333.00' E = 6.61' S.E. = N.C. CURVE DATA S.E. = N.C. P.I. = 106+34.97 "PR-RL1" E = 0.69' R = 510.00' L = 53.14' T = 26.60' Line "RL"Line "RL" & "PR-RL1" Lin e "S -1 -A" P.C. 106+08.38 "PR-RL1" P.R.C. 106+61.52 "PR-RL1" Lin e " S- 1 -A" & " P R- S1 A" asphalt P.I. 106+87.87 "PR-RL1" Lin e "P R-S 1 A" Line "PR-RL1" 42" rcp 1 0 5 15+00 20+00 Range Line Rd.Westfield Blvd. EARTHWORK SUMMARY =Cys. =Cys. =Cys. =Cys.Asphalt Removal =Cys.Borrow Topsoil Common Excavation** **Includes Asphalt Removal (Unsuitable Fill Material) *Includes Topsoil Str. No. 300 Str. No. 301 R /W R/W R/W Str. No. 308 Str. No. 400 Str. No. 307 Str. No. 349 Str. No. 309 104+00.00 "PR-RL1" BEGIN PROJECT Str. No. 302 Str. No. 303 Str. No. 304 Str. No. 305 Str. No. 402 Str. No. 344 Str. No. 345 Str. No. 306 P.O.T. 18+34.97 "RL" P.I. 106+34.97 "PR-RL1" = 850 820 810 800 840 830 850 conc. Str. No. 348 Constr. Limits App. Exist. R/W Constr. Limits 80' +50 P.L.(50.00') +55 P.L.(45.41') +00 50' +15 70' +15 70' +P.L.(+98.83) P.L.(45.45') +P.L.(+99.20) Ap p . P .L. & R/ W R/W P.T. 107+14.12 "PR-RL1" R/W 3 5 + 0 0 P.I. 3 4 + 9 8 . 1 1 "P R- S 1 A" R/W P.L.(44.46') +40 59' +15 "PR-S1A" R / W 43' +75 "PR-S1A" P.I. 36+75.13 "PR-S1A" P.O.T. 19+90.00 "RL" P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = CURVE DATA P.I. = 34+98.11 "PR-S1A" T = 103.21' L = 205.61' R = 950.00' E = 5.59' S.E. = N.C. 50' +00 60' +00 56' +85 54' +00 64' +07 "PR-S1A" Str. No. 346 Str . N o . 3 5 0 Str. No. 347 R/W S t r. No . 3 5 1 P.I. 108+56.97 "PR-RL1" 91' +97 "PR-S1A" 64' +90 Profile Grade Fill + 25%* CURVE DATA P.I. = 36+75.13 "PR-S1A" T = 74.62' L = 145.03' R = 250.00' E = 10.90' S.E. = N.C. Str. No. 310 80' +74.05 Temp. R/W 56.13' +P.L.(+71.64) Temp. R/W Temp. R/W Str. No. 303A COYOTE ENTERPRISES, LLC. Temp. R/W P.L.(82.74') +P.L.(+51.99) "RL" 59.29' +85.93 "RL" 3" pv c - force main 3" pv c - forcemain 3" pvc - forcemain 3" pvc - forcemain Str. No. 348A for Structure Details See Proj. No. 16-SW-85 5,110 4,640 3,270 3,250 490 A p p . P. L. R/W 80' +10 P.L.(45.00') +95 P.L.(46.85') +50 R/W R/W 70' +05 90' +25 Ap p . P. L. S-MART REAL ESTATE, INC. Temp. R/W 45' +00.53 50' +00.59 55' +50 75' +00 95' +20 LD LD E GM PP S T PP S T PPS T PP S T PP S T PPS T PPS T PP S T PPS T PP S T MB MAG MAG MAG MON MON MO N MO N MON MON MO N MON W W W WW W W W W W W W PP S T PP S T PP S T PP S T PP S T PP S T PPST RB -0 RB -0 RB -0 H H H H H H H H H CC-TR WV WV MON WV PP S T FF E PP S T GM GM RB -0 PP S T MB WV PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T PP S T FF E PP S T CC-TR T H WV C W V H WV RB -0 MAG MAG RB -0 H H H T PP S T PP S T PP S T G P F 101+00 102+00 103+00 104+00 105+00 106+00 107+00 108+00 109+00 82 1 .1 82 0 .2 81 9 .5 81 8 .7 81 8 .2 81 8 .0 81 7 .7 81 7 .7 81 7 .8 81 8 .1 81 8 .4 81 8 .7 81 8 .7 81 8 .9 81 9 .2 81 9 .5 81 9 .7 82 0 .0 8 1 8 . 7 0 8 1 9 . 0 5 8 2 0 . 0 0 8 1 9 . 4 0 Existing Ground +0.44% 104+00.00 "PR-RL1" BEGIN PROJECT P.G. EL. 818.53 105+75.00 "PR-RL1" See Roundabout Spot Elevations P . V.I . E L . 8 1 9 .4 3 P . V.I . 1 0 7 + 0 4 . 8 6 Profile Grade P . V.I . E L . 8 1 9 .8 1 P . V.I . 1 0 8 + 5 6 . 8 7 +0.70% Exist. 42" Pipe Exist. 42" Pipe Ex. 809.91 Ex. 810.15 Exist. 42" Pipe Ex. 810.18 Ex. 810.48 Str. No . 3 0 9 Exis t . M .H . 1 0 8 + 7 3 . 1 S t r. N o . 3 0 8 Ex is t . M .H . 1 0 8 + 2 4 .7 S t r. N o . 3 0 7 Ex ist. M. H . 1 0 7 + 6 7 .0 S t r. N o . 3 0 4 Ex is t. M.H . 1 0 6 + 4 8 .3 S t r. N o . 3 0 3 M. H . 1 0 5 + 8 0 .0 Exist. 42" Pipe Ex. 808.46 Ex. 809.62 S t r . N o . 3 0 5 I n le t 1 0 6 + 7 9 . 0 815.00 815.15 26' of 12" Pipe @ -0.58%Exist. 6" San. Sewer Pipe Ex. 814.34 S t r. N o . 4 0 2 Ex is t . S a n . M .H . 1 0 7 + 7 2 .1 Ex. 812.54 Ex. 811.74 S t r. N o . 4 0 0 Ex is t . S a n . M .H . 1 0 8 + 4 3 .8 42" Pipe Exist. Plotted 10' Below Datum BEGIN PROFILE GRADE 814.00 814.90 815.50 LINE "PR-RL1"NRM RJC NRM TJM BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 1" = 30' 1" = 10' PLAN AND PROFILE FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PP.PR-RL1.01.dgn5/24/2021 09:43:22 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 24 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Range Line Rd. No Curve Run �=0°01'27" RT. P.I. 20+00.00 "S-1-A" No Curve Run �=1°36'10" LT. P.I. 20+00.00 "RL" = Ap p . Exist. R /W 1 1 6 t h S t. Ap p . Ex is t . R/ W App. Exist. R/W KRG CENTRE LLCCORNER ASSOCIATES LP Ap p . Ex is t. R/ W Ap p . Se c ti o n Lin e Ap p . Exis t. R / W SPEEDWAY LLC App. Exist. R/W For Proposed Drainage Structures, see Construction Details. All Topography Information Described from Line "RL", Except as Noted. Line "PR-RL1" to be Constructed. All R/W Described from Line "PR-RL1", Except as Shown. NOTES: HAMILTON COUNTY CLAY TOWNSHIP SEC. 6, T 17 N, R 4 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 1, T 17 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E 820 810 800 840 830 (gas pumps) (gas pumps) (2-sty stone) conc. conc. con c. conc. conc. conc. conc. conc. conc. conc. conc. conc. con c. conc. con c. conc. con c. conc. conc. conc. con c. con c. conc. grass grassgras s grass grass grass grass grass grass grass grass grass grass grass grass grass gra ss grass grassgrassgrass gras s gra ss asph alt asphalt asph alt asphalt asph alt asphalt asphalt asphalt as ph alt planter planterplanter planter planter planter planter planter pla nter planter planter pla nter bu shes planter brick brick 2" pvc 6" pvc 8" p v c8" vcp 12 " vcp 8" pvc 8" pv c 30" rcp 12" rcp 6" pvc 12 " rcp 12" rcp 12 " rcp 12" rcp asph a lt 12" rcp 12 " rcp grass grass Conc. (brick Walgreens) 18 " rcp asphalt asphalt 42" rcp 42" rcp 8" vcp 42" rcp 6" vcp con c. asph a lt 21" rcp con c. conc. 30 " rcp 12" rcp 1 2 " rcp 12" rcp asphalt grass asphalt asphalt asphalt 21" rcp 12 " vcp to 12" cpp12" pvc 36" rcp 12" vcp 24" rcp 42" rcp 8" vcp 30 " rcp grass O/H Canopy O/H Canopy Ap p . P .L. Ap p . P .L. Ap p . P.L. (Autozone) planter ACQUISITION CORPORATION VCA REAL PROPERTY Easement Ingress/Egress 35.0' S H O P P E S W O O D L A N D +52 .3, 76 .8', Combinati on Pole +52 .8, 66 .7', Ha nd h o le +54 .1, 72 .6', Te le. Pe de sta l +54 .3, 70 .5', Combination Pole +55 .9, 76 .6', Tra ff ic Pe de sta l +65 .2, 77 .5', Ha nd h o le +66 .5, 82 .2', Inle t +66 .6, 82 .4', Clea no u t +72 .4, 36 .0', Tele. Manh o le +72 .9, 30 .4', Tele. Manh o le +93 .8, 73 .4', De tec tor Hou s ing 19 +29 .9, 45 .3', Rebar Found +41 .4, 53.6', CATV Pe de sta l +44.0, 54 .7', Traff ic S train Pole +45 .1, 47 .7', Wate r Valve +50 .9, 61 .3', Wate r Valve +51.2, 63 .6', Fire Hyd rant +52.0, 93 .4', G uy Wire +71 .5, 86 .0', Ga s Line Meter +74 .4, 61 .5', Wa te r Va lve +75 .0, 66 .1', Fire P lug +33 .1, 81 .4', Inle t +34 .3, 76 .6', Ha nd h o le +49 .2, 60 .6', Ha nd h o le +50 .8, 78 .9', Wate r Va lve +54 .8, 54 .8', Traff ic S train Pole +57 .0, 44 .5', Mon u m ent +57 .7, 84 .3', Gas Va lve +58 .1, 81 .7', Gas Line Ma rker +58 .8, 55 .8', Ha nd h o le 19 +04 .5, 63 .2', We ll +09 .5, 67.0', Misc. MH +11 .7, 76.8', Misc. MH +12 .0, 93.4', Post +14 .6, 91.8', P os t +15 .6, 68.1', Misc. MH +23 .8, 77.3', Misc. MH +24 .2, 91.8', P os t +26 .0, 47.6', We ll +26 .9, 93 .4', P ost +32 .7, 53 .7', Ligh t P ole +34 .7, 78 .3', Misc. MH +34 .8, 59 .3', P ost +37 .7, 82 .7', We ll +39 .3, 52 .2', Ha nd h o le +41 .8, 87 .6', We ll +44 .6, 53 .4', Tra ff ic S train P ole +48 .8, 47 .6', Mon u m ent +50 .7, 73 .1', Ligh t P ole +64 .4, 68 .0', Ha nd h o le 20 +04 .1, 73 .0', De tec tor Hou s ing +22 .8, 13 .4', Drainage Manh o le +39 .6, 46 .0', Drainage Manh ole +44 .9, 75 .8', Ha nd h o le +52 .0, 82 .7', Re ba r Fou n d +60 .8, 47 .3', Mon u m ent +61 .6, 61 .6', Ha nd h o le +66 .1, 53 .6', Tra ff ic S train P ole +66 .7, 75 .2', We ll +72 .1, 16 .1', Drainage Manh o le +72 .7, 50 .6', Traff ic P edes tal +73 .4, 31 .1', G as Va lve +78 .9, 48 .7', Ha nd h o le +87 .2, 34.6', P ost +90 .0, 50 .0', Re ba r Fou n d +91 .5, 32 .0', Inlet +91 .9, 53 .3', Ligh t P ole +99 .9, 68 .7', Inlet 8" pv c 1 0 + 0 0 Me d ic a l D r. HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E 88°58'05" App. Exist. R/W App. Exist. R/W App. Exist. R/W (brick CVS) planter con c. asphalt a s ph alt Conc. gra ss grass conc. 36" rcp12 " rcp 12" rcp 12 " rcp asphalt (TBM# 5 2 ) asph alt grass 8" cpp grass conc. grass plante r 12" rcp 36" rcp6" steel 12 " vcp asphalt 21 +21 .5, 80 .1', Pos t +23 .2, 92 .3', Pos t +24 .3, 79 .8', Pos t +30 .4, 94 .6', Cle a no u t +42 .5, 34 .1', Ligh t Pole 21 +44 .0, 34 .4', Ligh t Pole +49 .8, 40 .4', Mon u ment +58 .1, 80 .5', Pos t +59 .3, 92 .6', Pos t +61 .2, 80 .4', Pos t +63 .0, 35 .3', S prink ler Con trol Va lve +65 .9, 34 .7', Sign +93 .6, 81 .5', Pos t +97 .0, 81 .2', Pos t 22 +29 .0, 36 .7', Sa nit ary Manh o le 22 +30 .0, 31 .8', Inle t +32 .4, 32 .1', Inle t +32 .6, 13 .9', Dra ina ge Ma nh o le +33 .2, 69 .7', Inle t +45 .1, 67 .2', Cle a no u t +45 .4, 68 .7', P os t +46 .1, 63 .4', P os t +46 .3, 61 .0', P os t +46 .3, 66 .1', P os t +50 .0, 51 .8', Hose Bib +50 .1, 44 .5', Fire Hyd rant +53 .3, 50 .7', Sign +53 .3, 58 .4', Sign +58 .3, 60 .5', Inle t +58 .8, 42 .6', S prink ler Con trol Va lve +62 .3, 31 .4', Inle t +68 .2, 25 .9', Detec tor Hou sing +68 .6, 34 .0', Ha nd h o le 23 +09 .6, 62 .1', Ligh t Pole +10 .5, 56 .0', Tre e 23 +18 .4, 44 .9', Tree +18 .6, 47 .2', Inle t +29 .8, 42 .8', Ha nd h o le +34 .5, 43 .0', Tre e +41 .4, 43 .2', Tre e +68 .7, 41 .4', Te le. P e de s ta l +68 .8, 34 .9', Sign +76 .2, 40 .2', Mag Na il +81 .6, 42 .2', Tre e +93 .8, 43 .1', Tre e +96 .0, 81 .0', Pos t +99 .8, 42 .8', Tre e 24 +14 .0, 27 .7', Detec tor Hou sing +18 .9, 42 .4', Tre e +38 .8, 95 .1', Sign +40 .7, 52 .5', Grou n d Ligh t +44 .1, 46 .8', Sign +44 .1, 60 .4', Sign +44 .3, 33 .0', Sa nit a ry Manh o le +47 .6, 82 .6', Tre e +49 .7, 53 .5', Grou n d Ligh t 24 +52 .9, 42 .2', Tre e +54 .4, 14 .8', Dra ina ge Ma nh o le +56 .6, 60 .2', Ligh t Pole +62 .7, 47 .1', Inle t +69 .0, 53 .2', Inle t +85 .2, 44 .2', Tre e +85 .7, 60 .2', Tre e +90 .6, 90 .9', Mon u ment +92 .9, 42 .7', Bus h +93 .2, 45 .4', S prink ler Con trol Va lve +96 .8, 43 .4', Bus h 25 +01 .9, 42 .7', Tree 25 +07 .6, 42 .0', Tre e +08 .8, 42 .8', Bus h +13 .4, 42 .4', Bus h +23 .5, 43 .1', Bus h +26 .2, 42 .4', Bus h +26 .8, 46 .2', Ligh t Pole +43 .4, 42 .5', Tre e +49 .3, 18 .8', Te le. Manh o le +50 .9, 41 .6', Tre e +55 .7, 38 .1', CATV Pe desta l +58 .4, 27 .7', Ha nd h o le +59 .8, 42 .4', Tre e +70 .0, 38 .4', Te le. P e de s ta l +70 .6, 28 .1', Ha nd h o le +73 .2, 50 .6', Gas Valve +75 .0, 37 .8', Rebar Fou n d +85 .4, 41 .8', Tre e +92 .2, 42 .7', Bus h 26 +00 .8, 41 .9', Tree 26 +05 .6, 42 .2', Tre e +08 .3, 86 .3', Inle t +23 .7, 57 .0', Clea no u t +25 .5, 65 .5', Ligh t Pole +25 .6, 29 .6', Mon u ment +29 .7, 27 .4', Ha nd h o le +31 .5, 36 .3', Tra ff ic Pe de sta l +32 .4, 47 .6', Bush +35 .3, 46 .8', Bus h +37 .3, 62 .6', Ligh t Pole +37 .6, 62 .1', Ligh t Pole +41 .7, 54 .9', Tre e +43 .7, 46 .6', Wa te r Meter +45 .1, 41 .0', Hand h o le +45 .7, 36 .5', Mon u ment +50 .6, 56 .0', Bus h +54 .0, 74 .3', Tre e +54 .1, 96 .2', Tre e +57 .9, 82 .5', Ligh t Pole +61 .9, 38 .2', Detec tor Hou sing +81 .3, 31 .9', Wa te r Va lve +86 .2, 55 .1', Dete c tor Hou sing +94 .8, 97 .0', Tre e +94 .9, 40 .0', Fire Hyd rant +95 .7, 57 .0', Tre e +96 .0, 36 .7', Wa te r Va lve +96 .4, 52 .5', Hand h o le +97 .8, 81 .0', Ligh t Pole +99 .1, 44 .3', Hand h o le 27 +01 .4, 55 .8', Sign +02 .0, 44 .2', Traff ic S train Pole +02 .6, 67 .9', Sign +03 .2, 99 .2', Tre e +16 .5, 26 .1', Inlet +18 .4, 27 .7', Wa te r Va lve +20 .6, 26 .2', Inle t +27 .4, 39 .4', Ha nd h o le +27 .9, 66 .1', Ligh t Pole +33 .0, 47 .2', Inle t +41 .7, 32 .7', Tre e AUTOZONE INC +58 .5, 32 .7', Sa n. Mh. Sprink le r C on trol Va lve +19 .5, 31 .5', +15 .6, 16 .2', Dra ina ge Mh. Traff ic S train Pole 27 +09 .1, 36 .8', Traff ic S train Pole +40 .8, 39 .7', +16 .9, 48 .2', Drainage Mh. El. 829.45 of Intersection Medical Dr. & 40'± W of � Rangeline Rd. TBM #52 - Chisled "X" on E most Bolt of Fire Hydrant at NW Cor. Line "RL"Line "RL" & "PR-RL1" CURVE DATA P.I. = 108+56.97 "PR-RL1" T = 66.69' L = 131.64' R = 333.00' E = 6.61' S.E. = N.C. Lin e "S -1 -A" & "PR -S 1 A" P.T. 107+14.12 "PR-RL1" 2 0 + 0 0 P.I. 108+56.97 "PR-RL1" Lin e "S -1 -A" 20 +26 .0, 83 .3', Dra ina ge Mh. asph alt Line "PR-RL1" P.O.T. 21+58.81 "RL" P.I. 109+60.52 "PR-RL1"= P.T. 109+98.97 "PR-RL1" P.R.C. 109+21.92 "PR-RL1" CURVE DATA P.I. = 109+60.52 "PR-RL1" T = 38.60' L = 77.05' R = 510.00' E = 1.46' S.E. = N.C. 1 1 0 1 1 5 25+00 20+00 12" cpp Westfield Blvd. Str. No. 315Str. No. 312Str. No. 308 Str. No. 400 Str. No. 349 Str. No. 307 Str. No. 316 Str. No. 314 Str. No. 317 Str. No. 344 Str. No. 345 850 820 810 800 840 830 850 1 2 " rcp Str. No. 346 Str. No. 347 Constr. Limits Constr. LimitsR/W Str. No. 309 App. P.L. App. P.L. & R/W Ap p . P.L. & R/ WS t r. No . 3 5 1 P.L.(50.02') +P.L.(+75.76) 50' +P.L.(+10.76) 42" rcp App. Exist. R/W App. Exist. R/W R /W 43' +75 "PR-S1A" P . I. 3 4 + 9 8 . 1 1 "P R -S 1 A" 59' +15 "PR-S1A" P.O.T. 19+90.00 "RL" P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = 54' +00 3 5 + 0 0 P.I. 36+75.13 "PR-S1A" Lin e "P R-S 1 A" CURVE DATA P.I. = 34+98.11 "PR-S1A" T = 103.21' L = 205.61' R = 950.00' E = 5.59' S.E. = N.C. R/W S tr. N o . 4 0 2 Str . N o . 3 5 0 R/W Str. No. 310 a s ph alt Str. No. 348 64' +07 "PR-S1A" Str. No. 401 Str. No. 317A Str. No. 401A Str. No. 401B +0.70% Profile Grade conc. 70' +P.L.(+10.44) 70' +P.L.(+75.44) 64' +90 59' +19 64' +20 91' +97 "PR-S1A" RW(50.01') +20 L = 60.19' CURVE DATA T = 30.24' P.I. = 11+50.96 "PR-S2A" R = 250.00' E = 1.82' S.E. = N.C. CURVE DATA T = 20.14' L = 40.20' P.I. = 13+28.94 "PR-S2A" R = 250.00' E = 0.81' S.E. = N.C. P . C. 1 1 + 2 0 .7 2 "PR -S 2 A" P.I. 11+50.96 "PR-S2A" P.T. 11+80.91 "PR-S2A" Lin e "P R- S2 A" P.T. 13+48.99 "PR-S2A" & "P R-S 2 A" Lin e "S- 2 - A" No Curve Run �=22°49'37" LT. P.I. 12+25.69 "PR-S2A" = 98°10'54" P.O.T. 10+95.21 "S-2-A" P.I. 13+28.94 "PR-S2A"= P.O.T. 12+32.76 "PR-S2A" P.O.T. 114+61.91 "PR-RL1"= Str. No. 518 Str. No. 520 Str. No. 519 App. Section Line Str. No. 521 Str. No. 502Str. No. 501 Lin e "S- 2 -A" P.O.T. 10+00.00 "S-2-A" P.O.T. 26+75.74 "RL" = P.O.T. 114+77.31 "PR-RL1"= Str. No. 503 Str. No. 504 Str. No. 505 con c. ov e rha ng ov erhang CURVE DATA P.I. = 36+75.13 "PR-S1A" T = 74.62' L = 145.03' R = 250.00' E = 10.90' S.E. = N.C. Str. No. 506 Str. No. 507 Constr. Limits Constr. Limits Constr. Limits Temp. R/W Temp. R/W Temp. R/W Temp. R/W Temp. R/W Temp. R/W 46.71' +35 50' +35 47' +80 65' +80 63' +05 48' +05 (56.13') +P.L. (+71.64) 48' +P.L.(+85.80) 50' +P.L.(+85.76) R/W R/W R/W R/W R/W 70' +37 70' +15 P.L. (45') +34 P.L. (45') +89 45.45' +15.99 32' +18 "PR-S2A" 38' +17 61' +09 45' +09 Temp. R/W Temp. R/W Temp. R/W S-MART REAL ESTATE, INC. Temp. R/W Temp. R/W +50 .2, 45 .8', Sprink le r Va lve Constr. Limits Temp. R/W 50' +15 47' +15 47' +53.03 47' +61.58 Temp. R/W 60' +24 49.50' +99.50 52' +97 52' +89 Temp. R/W 63' +15 P.L. (45') +27 P.L.(82.74') +P.L.(+51.99) "RL" 59.29' +85.93 "RL" P.L.(50.00') +24.03 "RL" Ap p . Exist. R/W Ap p . Exis t. R / W II COMPANY INVESTMENTS BARNES P.C. 13+08.79 "PR-S2A" 23' +18 "PR-S2A" 35' +28 "PR-S2A" 35' +30 "PR-S2A" P.L.(36.07') +25 "PR-S2A" 24' +18 "PR-S2A" 41.79' +25 "PR-S2A" Temp. R/W Temp. R/W 3" pv c - force main 70' +05 90' +25 R/W R/W Temp. R/W LD LD LD LD LD LD H H H EM EM E GM PP S T PP S T PPS T PPS T PP S T PP S T PP S T PP S T PP S T PPS T PPS T PPS T PPS T PP S T PP S T PPST PP S T PP S T PPST PPST MAG MAG MON MON MON MON MON MON W W W W W W PP S T PP S T PPS T PPS T PP S T PP S T PP S T PP S T PP S T PP S T PP ST PP S T PP S T RB -0 T T H H H H H H H H H H CC-TR CC -TR C WM WV W V WV WV WV W V CC -TR T H W V C WV H RB -0 RB-0 MAG H B PZZZ PZZ Z PZZZ PZZ Z PZZZ PZZ Z H H H H T MON PPST PPST PPST PPST PP ST PPST PPST PPST PP S T PPST PPST G P F 107+00 108+00 109+00 110+00 111+00 112+00 113+00 114+00 115+00 81 8 .9 81 9 .2 81 9 .5 81 9 .7 82 0 .0 82 0 .3 82 0 .5 82 0 .8 82 1 .0 82 1 .4 82 1 .9 82 2 .5 82 3 .1 82 4 .0 82 5 .0 82 6 .3 82 7 .7 82 9 .4 8 2 0 . 0 0 8 2 0 . 2 2 8 2 0 . 4 4 8 1 9 . 4 0 Existing Ground +0.44% Profile Grade P.G. EL. 820.22 109+50.00 "PR-RL1" See Roundabout Spot Elevations P . V.I . E L . 8 1 9 .4 3 P . V.I . 1 0 7 + 0 4 . 8 6 P . V.I . E L . 8 1 9 .8 1 P . V.I . 1 0 8 + 5 6 . 8 7 Exist. 42" Pipe Ex. 810.15 Exist. 42" Pipe Ex. 810.18 Ex. 810.48 Exist. 42" Pipe Exist. 42" Pipe Ex. 821.04 Exist. 36" Pipe S t r. N o . 3 1 6 Ex is t . M .H . 1 1 0 + 3 4 .2 Str. No . 3 0 9 Exis t . M .H . 1 0 8 + 7 3 . 1 S t r. N o . 3 0 8 Ex is t . M .H . 1 0 8 + 2 4 .7 S t r. N o . 3 0 7 Ex ist. M. H . 1 0 7 + 6 7 .0 Ex. 809.27 Exist. 12" San. Sewer Pipe Ex. 810.23 Ex. 810.08 S t r. N o . 4 0 1 Ex is t . S a n . M .H . 1 1 0 + 3 0 .6 Ex. 811.20 Ex. 811.15 Exist. 8" San. Sewer Pipe Exist. 6" San. Sewer Pipe Ex. 814.34 S t r. N o . 4 0 2 Ex is t . S a n . M .H . 1 0 7 + 7 2 .1 Ex. 812.54 Ex. 811.74 S t r. N o . 4 0 0 Ex is t . S a n . M .H . 1 0 8 + 4 3 .8 Exist. 8" San. Sewer Pipe Ex. 815.11 42" Pipe Exist. Plotted 10' Below Datum Plotted 10' Below Datum S t r . N o . 4 0 1 A Ex is t. S a n . M. H . 1 1 2 + 4 5 .9 S t r . N o . 3 1 7 A Ex is t. M. H . 1 1 2 + 5 5 .9 S t r . N o . 4 0 1 B Ex is t. S a n . M. H . 1 1 4 + 6 0 .1 END PROFILE GRADE 814.90 815.50 S t r. N o . 5 0 6 Ex is t. M.H . 1 1 5 + 1 7 .1 822.80 Ex. 818.34 S t r. N o . 5 0 3 M. H . 1 1 4 + 0 1 .0 821.00 NRM TJM NRM RJC LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 1" = 30' 1" = 10' PLAN AND PROFILE FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PP.PR-RL1.02.dgn5/24/2021 09:43:24 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 25 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E 810 820 830 840 For Proposed Drainage Structures, see Construction Details. All Topography Information Described from Line "RL", Except as Noted. Line "PR-RL1" to be Constructed. All R/W Described from Line "PR-RL1", Except as Shown. NOTES: (2-sty brick) conc. conc. conc. con c. conc. conc. conc. con c. conc. conc. conc. conc. conc. con c. conc. conc. conc. conc. conc. conc. con c. conc. conc. conc. conc. grass grass grass gra s s grass grass grass grass grass gras s grass grass grass grass grass grass grass grass grass grass grass grass grass grassgrass stone ston e asphalt asph alt asphalt a s phalt asph a lt a sph alt asph altasphalt asphalt asph alt asphalt aspha lt asph alt asph alt asphalt riprap pla nter pla nter planter plante r planter planter planter pla nter planter planter planter planter planter planter planter planter planter pla nter planter planter planter brick brick 8" cpp 24 " cpp 12" rcp 12 " rcp 18 " cpp 12 " rcp 42 " rcp 12 " rcp 12" rcp 12" rcp 12" rc p 4" cpp 12 " rcp 27 +01 .4, 55 .8', Sign +02 .0, 44 .2', Traff ic Strain Pole +02 .6, 67 .9', Sign +03 .2, 99 .2', Tree 27 +09 .1, 36 .8', Tra ff ic Stra in P ole +15 .6, 16 .2', Dra ina ge Manh o le +16 .5, 26 .1', Inlet +16 .9, 48 .2', Drainage Manh o le +18 .4, 27 .7', Wa ter Va lve +19 .5, 31 .5', S prink ler Con trol Va lve +20 .6, 26 .2', Inle t +27 .4, 39 .4', Hand h o le +27 .9, 66 .1', Ligh t Pole +33 .0, 47 .2', Inlet +41 .7, 32 .7', Tre e +56 .9, 42 .7', Tree +83 .5, 35 .9', Te le. Manh o le +86 .8, 29 .4', Tre e +94 .5, 16 .6', Dra ina ge Manh o le 28 +03 .3, 31 .4', Inle t 28 +13 .0, 41 .2', Tree +26 .8, 95 .0', Tree +33 .0, 49 .8', P os t +33 .3, 31 .3', Tre e +34 .6, 50 .3', P os t +36 .1, 46 .2', S prink le r Con trol Va lve +38 .4, 49 .6', P os t +49 .6, 47 .2', Inlet +59 .1, 41 .0', Tree +61 .6, 93 .5', Tree +70 .2, 60 .9', Dra ina ge Manh o le +75 .2, 29 .9', Tre e +78 .8, 60 .6', Ligh t Pole +82 .1, 60 .7', P ost +84 .7, 62 .6', P ost +89 .5, 96 .7', Mon u me nt +93 .6, 29 .9', Mag Na il +99 .1, 46 .8', Ha nd h o le 29 +01 .8, 40 .5', Tele . P edes tal 29 +04 .0, 47 .9', S ign +25 .6, 48 .7', Inlet +30 .0, 2.0', Detec tor Hou sing +35 .7, 46 .7', S ign +52 .1, 44 .8', Tre e +52 .8, 39 .3', Gas Va lve +53 .5, 39 .5', Gas Line Marker +54 .4, 46 .3', S prink ler Con trol Va lve +81 .5, 59 .6', Inle t +82 .9, 43 .5', Wa ter Va lve +83 .0, 40 .4', Fire Hyd ra nt +86 .5, 49 .4', Inlet 30 +17 .6, 57 .6', Inlet +21 .9, 59 .3', G rou n d Ligh t +34 .6, 40 .3', S prink le r Con trol Va lve +36 .5, 50 .8', Hose Bib +37 .4, 56 .8', P ost +37 .6, 54 .0', P ost +37 .6, 59 .4', P ost +37 .7, 62 .2', P ost 30 +60 .7, 36 .7', Tre e +68 .5, 61 .3', Inle t +69 .4, 18 .6', Dra ina ge Manh o le +75 .2, 31 .2', Tre e +85 .6, 50 .0', S prink le r Con trol Va lve +87 .9, 36 .6', Hand h o le +99 .2, 40 .4', Re bar Fou n d 31 +00 .6, 44 .6', CATV P edes tal +05 .1, 46 .4', Wa ter Va lve +21 .4, 18 .8', Te le. Manh o le 31 +23 .0, 40 .3', Gas Valve +32 .3, 30 .7', Tre e +33 .0, 55 .2', Cle a no u t +48 .3, 31 .3', Tre e +50 .7, 47 .1', Tree +70 .1, 31 .4', Tre e +83 .9, 66 .8', Inlet +86 .8, 29 .7', Mon u me nt +89 .5, 47 .2', Cle a no u t 32 +09 .2, 58 .0', S ign +09 .7, 46 .5', S ign 32 +12 .0, 46 .1', Tree +22 .0, 36 .7', Tele . P edes tal +26 .0, 59 .8', Ligh t Pole +27 .6, 38 .7', Sign +32 .2, 38 .4', Tre e +33 .6, 25 .2', Inlet +34 .4, 26 .1', Inle t +37 .1, 33 .4', Drainage Manh o le +60 .4, 37 .9', Tre e +70 .7, 44 .4', Tree +84 .9, 36 .6', CATV P edes tal +85 .2, 38 .4', Tre e +86 .1, 38 .4', Sign +90 .6, 65 .6', Drainage Manh o le 33 +08 .6, 27 .2', Gas Line Marker +13 .3, 37 .6', Tre e 33 +19 .5, 41 .4', Sign +24 .7, 40 .1', Bee hive Inlet +25 .1, 31 .2', Drainage Manh o le +31 .8, 63 .4', Inlet +39 .7, 60 .8', S ign +40 .0, 49 .1', S ign +60 .5, 52 .4', Wa te r Mete r +85 .1, 62 .8', Inlet +85 .1, 46 .2', S anit ary Manh o le +87 .2, 53 .6', Drainage Manh o le +88 .3, 62 .5', S prink le r Con trol Va lve +95 .2, 53 .8', Ligh t Pole 34 +05 .9, 40 .9', Tre e 34 +07 .5, 46 .5', Misc. MH +30 .4, 40 .5', Tre e +43 .7, 41 .1', Tree +48 .3, 61 .8', G rou n d Ligh t +53 .9, 30 .9', Mon u me nt +54 .2, 64 .0', Ligh t Pole +54 .8, 62 .2', Sign +55 .8, 48 .6', Sign +59 .9, 62 .4', G rou n d Ligh t +67 .1, 41 .9', Tree +73 .0, 49 .3', Sign +73 .1, 42 .8', Tre e +80 .2, 23 .8', De te c tor Hou sing +80 .3, 30 .9', Ha nd h o le 35 +05 .5, 39 .8', CATV Pe de sta l 35 +07 .6, 61 .7', Tree +10 .9, 47 .5', Hand h o le +12 .3, 45 .1', Re bar Fou n d +23 .4, 56 .9', Grou n d Ligh t +23 .9, 55 .2', Tre e +24 .3, 50 .6', Ligh t Pole +25 .3, 54 .0', Grou n d Ligh t +56 .3, 40 .4', Drainage Manh o le +56 .5, 31 .7', Inlet +69 .3, 53 .1', Tre e +69 .3, 50 .4', Tra nsformer +69 .6, 50 .8', Grou n d Ligh t +74 .3, 32 .0', Inle t +80 .6, 45 .0', Gas Va lve +88 .8, 50 .7', Sign +89 .0, 59 .0', Sign (brick CVS) (12 " brick wall) asphalt asphalt grass asphalt 1 2 " r c p 36" rcp asphalt conc. 36" rcp 12" rcp 4" cpp asphalt grass asphalt 1 2 " r c p 12 " rcp 36" rcp 12 " rcp 36" rcp 12" rcp asphalt 12" rcp 36" rcp 12 " rcp 12" rcp 36" rcp 1 2" rcp 1 2" rcp 12 " rcp 8" cpp 12" rcp 12 " rcp 12" rcp (2-sty brick) asphalt gra ss 36" rcp con c. con c. Ap p . P .L. Ap p . P.L. Ap p . P.L. Ap p . P.L. Ap p . P.L. Ap p . P .L. Ap p . P.L. Range Line Rd. asphalt App. Section Line KRG CENTRE LLC ENTERPRISES J & J REALTY FINEBERG GROUP LLC +60 .2, 28 .2', S prink ler Valve II COMPANY BARNES INVESTMENTS D & W HOLDINGS LLC REVOCABLE LIVING TRUST PATRICIA R. EMMERT FINEBERG GROUP LLC App. Exist. R/W App. Exist. R/Wgrass grass App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W STORES LLC MACS CONVENIENCEOPERATIONS LLC BFS RETAIL & COMMERCIAL Line "RL" & "PR- RL1" 850 860 1 1 5 1 2 0 30+00 35+00 conc. Str. No. 318 Str. No. 320 Str. No. 319 Str. No. 321 Str. No. 322 810 820 830 840 850 860 Str. No. 323 Str. No. 324 Constr. Limits Constr. Limits Constr. Limits Constr. Limits 12" cpp Str. No. 325 Str. No. 326 122+12.93 "PR-RL1" INCIDENTAL CONSTRUCTION END PROJECT & BEGIN conc. 64' +P.L.(+63.45) 64' +10 50' +10 50' +P.L.(+00.84) 50' +P.L.(+81.67) Str. No. 509 Str. No. 511 Str. No. 508 App. Exist. R/W Str. No. 517 Str. No. 516 Str. No. 512 36" rcp Str. No. 510Str. No. 506 Str. No. 507 Str. No. 513 Str. No. 514 Str. No. 515 Str. No. 318A Constr. Limits 70' +15 P.L. (45') +34 45.45' +15.99 Temp. R/W Temp. R/W Temp. R/W Temp. R/W Temp. R/W Temp. R/W R/W P.L. (45') +00 54' +00 54' +10 60' +10 60' +P.L. (+00.93) 50' +P.L.(+63.69) Temp. R/W 63' +15 P.L. (45') +27 Ap p . Exis t. R / W 24' +18 "PR-S2A" P.L.(36.07') +25 "PR-S2A" R/W Constr. Limits 45' +40 50' +40 45' +85 50' +85 Temp. R/W 41.79' +25 "PR-S2A" Temp. R/W Temp. R/W 45.83' +16.70 64' +16.28 Do Not Disturb Sign Constr. Limits Constr. Limits Constr. Limits Constr. Limits 115+00 116+00 117+00 118+00 119+00 120+00 121+00 122+00 123+00 124+00 82 7 .7 82 9 .4 83 1 .3 83 3 .2 83 5 .1 83 6 .9 83 8 .4 83 9 .6 84 0 .6 84 1 .4 84 2 .1 84 2 .9 84 3 .7 84 4 .4 84 5 .1 84 5 .7 84 6 .4 84 7 .2 84 7 .7 PP S T PP S T PP S T H WV H MON H PP S T PP S T T W V PP S T PP S T PP S T PP S T LD H C W V T C WM G H B PZZZ PZZ Z G MON T MON H H FP H H836.0848344BRK Existing Ground Ex. 821.04 Ex. 823.66 Ex. 823.56 Exist. 36" Pipe Exist. 36" Pipe Ex. 831.86 Ex. 832.34 Exist. 36" Pipe Ex. 832.57Ex. 832.47 Exist. 36" Pipe Exist. 36" Pipe Ex. 832.97Ex. 832.96 S tr . No . 3 2 4 E xis t . M. H. 1 2 3 + 5 7 . 9 S t r. N o . 3 2 2 Ex is t . M .H . 1 2 1 + 2 6 .6 Str. N o . 3 2 1 Exis t . M .H . 1 2 0 + 3 8 . 6 Str. No . 3 1 8 Exis t . M .H . 1 1 8 + 7 0 . 9 841.00 24' of 12" Pipe @ -0.50% 841.12 S t r. N o . 3 2 3 In le t 1 2 1 + 5 0 .0 122+12.93 "PR-RL1" INCIDENTAL CONSTRUCTION END PROJECT & BEGIN Exist. 36" Pipe S t r. N o . 5 0 6 Ex is t. M.H . 1 1 5 + 1 7 .1 S tr . No . 5 1 3 E xis t . M.H. 1 1 5 + 9 6 . 1 832.36 S t r . N o . 5 1 7 M. H . 1 1 8 + 0 0 .0 Ex. 829.70 832.36 Ex. 822.32 S tr . No . 5 1 0 M. H. 1 1 5 + 6 0 .0 822.80 824.97 825.30 NRM TJM NRM RJC LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 1" = 30' 1" = 10' PLAN AND PROFILE FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PP.PR-RL1.03.dgn5/24/2021 09:43:25 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 26 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E 810 820 830 840 con c. con c. conc. conc. conc. conc. conc. gra ss grass grass grass grass grass grass stone a sph alt asph alt asphalt pla nter planter plante r planter planter planter brickbrick 12 " rcp 34 +05 .9, 40 .9', Tree +30 .4, 40 .5', Tree +43 .7, 41 .1', Tree +48 .3, 61 .8', Grou n d Ligh t +53 .9, 30 .9', Mon u ment +54 .2, 64 .0', Ligh t P ole +54 .8, 62 .2', S ign +55 .8, 48 .6', S ign +59 .9, 62 .4', Grou n d Ligh t +67 .1, 41 .9', Tree +73 .0, 49 .3', S ign +73 .1, 42 .8', Tree +80 .2, 23 .8', Detec tor Hou sing +80 .3, 30 .9', Hand h o le 35 +05 .5, 39 .8', CATV P edestal 35 +07 .6, 61 .7', Tree +10 .9, 47 .5', Hand h o le +12 .3, 45 .1', Rebar Fou n d +23 .4, 56 .9', Grou n d Ligh t +23 .9, 55 .2', Tree +24 .3, 50 .6', Ligh t P ole +25 .3, 54 .0', Grou n d Ligh t +56 .3, 40 .4', Dra ina ge Ma nh o le +56 .5, 31 .7', Inlet +69 .3, 53 .1', Tree +69 .3, 50 .4', Trans forme r +69 .6, 50 .8', Grou n d Ligh t +74 .3, 32 .0', Inlet +80 .6, 45 .0', Ga s Valve +88 .8, 50 .7', S ign +89 .0, 59 .0', S ign 1 2 " r c p 36" rcp asphalt conc. 36" rcp Ap p . P .L. App. Section Line FINEBERG GROUP LLC FINEBERG GROUP LLC App. Exist. R/W App. Exist. R/W App. Exist. R/W STORES LLC MACS CONVENIENCE 850 860 35+00 810 820 830 840 850 860 Str. No. 324 Constr. Limits For Proposed Drainage Structures, see Construction Details. All Topography Information Described from Line "RL", Except as Noted. Line "PR-RL1" to be Constructed. All R/W Described from Line "PR-RL1", Except as Shown. NOTES: 1 2 5 conc. Range Line Rd. Constr. Limits 40 +24 .0, 37 .6', Mon u me nt +40 .7, 64 .9', Ga s Valve +40 .8, 67 .1', Ga s Line Marke r +78 .4, 30 .6', Hand h o le 41 +43 .2, 32 .7', Draina ge Ma nh o le +43 .4, 26 .0', Inlet 42 +67 .0, 16 .8', Tele . Ma nh o le 43 +33 .3, 26 .0', Inlet +34 .2, 32 .8', Draina ge Ma nh o le App. Exist. R/W asphalt con c. planter con c. grass 12 " rcp asphalt conc. grass grass 12 " rcp App. Exist. R/W conc. grass grass asphalt planter asphaltasph alt App. Exist. R/W grass planter conc. grass grass planter 30" rcp 30" rcp 12 " rcp grass (1-sty metal) App. Exist. R/Wgrass conc. 40 +16 .8, 51 .6', Ligh t Pole +18 .6, 58 .2', Tre e +33 .6, 34 .6', Mon u m ent +36 .5, 47 .6', Tre e +82 .6, 49 .4', Tre e +97 .0, 50 .6', Ligh t P ole 41 +25 .5, 35 .3', Rebar Fou n d +44 .8, 26 .3', Inle t +60 .1, 48 .6', Tre e 42 +05 .8, 48 .2', Tree +22 .1, 51 .5', Ligh t Pole +49 .1, 50 .3', Tre e +75 .5, 28 .3', Sign +80 .9, 37 .5', Tele . P edestal +92 .6, 48 .9', Tre e 43 +18 .3, 36 .2', Fire Hyd ra nt +34 .2, 46 .9', Tre e +35 .4, 26 .1', Inle t +46 .9, 52 .0', Ligh t P ole Constr. Limits App. Exist. R/W con c. (2-sty brick) grass grass conc. conc. Ap p . E xis t. R / W Ap p . E xis t. R / W Ap p . P . L. Ap p . E x is t . R/ W Ca r m e l D r . Ap p . Ex is t . R / W Ap p . Ex is t . R / W CITY OF CARMEL asphalt asph a lt 36" rcp 30" rcp asphalt Ap p . P.L. Line "RL" & "PR-RL1"40+00 grass station (typ) lids for gas grassconc. asphalt conc. grass grass con c. c o n c. g r a s s stone ri pr a p conc.grass grass grass pla nter con c. gra ss conc. conc. gra ss grass planter con c. grass conc. conc. asphalt con c.grass grass conc. grass grass c o n c. conc. con c. grass grass grass conc. conc. grass 1 5 " h d p e 12 " rcp 12" hdpe 1 5 " h d p e 15" hdpe 15" hdpe 15" hdpe 1 2 " hd p e 15" hdpe 36" rcp 12 " rcp App. Exist. R/W asph alt asph alt asph a lt grass grass conc. c o n c. (2-sty brick) asphalt conc. conc. CARMEL DEVELOPMENT II LLC BARNES INVESTMENT COMPANY KROGER LIMITED PTN 1 REAL ESTATE DEPT 36 +04 .2, 47 .4', Grou n d Ligh t +05 .6, 46 .9', Tree +06 .0, 45 .9', Trans forme r +07 .7, 47 .2', Grou n d Ligh t +11 .0, 34 .3', Mon u me nt +25 .9, 49 .6', Trans forme r +49 .5, 49 .4', Trans forme r +49 .7, 49 .0', Grou n d Ligh t +52 .2, 47 .5', Tree +53 .8, 47 .4', Grou n d Ligh t +61 .6, 33 .7', Ligh t Pole +75 .1, 33 .5', Hand h o le +81 .3, 51 .0', Trans forme r +83 .2, 49 .7', Tree +91 .4, 40 .9', Post 37 +01 .1, 46 .7', Post +02 .6, 54 .0', Traff ic Stra in Pole +05 .9, 50 .5', Traff ic Stra in Pole +08 .6, 55 .3', Post +12 .6, 66 .0', Post +25 .1, 40 .3', Wate r Valve +27 .8, 36 .9', Wate r Valve +30 .8, 40 .1', Wate r Valve +77 .2, 83 .3', Inlet +89 .4, 44 .9', Wate r Valve +90 .6, 41 .1', Wate r Valve 38 +05 .5, 48 .9', Fire Hyd rant +09 .8, 42 .0', Mon u me nt +10 .0, 47 .5', Traff ic Stra in Pole +20 .1, 60 .4', Tree +26 .4, 33 .3', Hand h o le +49 .7, 50 .3', Tree +50 .0, 35 .2', Ligh t Pole +72 .0, 58 .8', C lea no u t 39 +02 .7, 48 .6', Tree +23 .7, 58 .0', C lea no u t +24 .0, 57 .5', C lea no u t +25 .8, 57 .4', Post +28 .7, 57 .2', Post +30 .9, 57 .5', Post +33 .2, 57 .8', Post +38 .3, 44 .2', Tree +59 .4, 47 .8', Hand h o le +95 .9, 41 .3', Sign +47 .5, 83 .6', Misc. MH +50 .8, 84 .1', Misc. MH +54 .8, 52 .9', Ligh t P ole +57 .2, 84 .4', Misc. MH +67 .5, 34 .5', Ligh t P ole +67 .8, 85 .6', Misc. MH +71 .3, 47 .2', Ele c tric Pedestal +72 .1, 51 .0', Flag P ole +75 .1, 51 .6', Grou n d Ligh t +75 .3, 81 .8', Misc. MH +79 .1, 54 .0', Hand h o le +79 .3, 45 .0', Reba r Fou n d +87 .9, 51 .2', Hand h o le +87 .9, 52 .0', Uti l i t y Line Marker +89 .9, 44 .8', Hand h o le +91 .8, 25 .2', Hand h o le +91 .9, 19 .6', Hand h o le +92 .2, 39 .5', Ma g Nail +98 .9, 58 .3', Uti l i t y Line Marker 37 +00 .5, 53 .5', C ATV Pedestal +00 .8, 57 .5', Hand h o le +03 .3, 52 .0', C ATV Pedestal +03 .8, 54 .7', Tra ff ic S train P ole +05 .8, 64 .8', Tra ff ic S train P ole +16 .5, 82 .6', Hand h o le +76 .6, 33 .6', Dra ina ge Ma nh o le +78 .4, 82 .3', Inlet +89 .5, 66 .4', Post +95 .2, 56 .6', Post +97 .8, 51 .8', Tra ff ic S train P ole 38 +01 .3, 55 .6', Tra ff ic S train P ole +03 .3, 48 .7', Post +05 .4, 59 .7', Tree +06 .8, 53 .2', Uti l i t y Line Marker +08 .9, 60 .0', Ligh t P ole +09 .1, 53 .0', Hand h o le +13 .3, 43 .3', Post +24 .3, 40 .5', Post +28 .9, 34 .2', Hand h o le +35 .5, 45 .0', Post +35 .9, 40 .2', Post +37 .9, 43 .3', Tele. Pedestal +38 .0, 45 .1', Post +40 .3, 44 .6', Post +41 .8, 34 .2', Ligh t P ole +47 .4, 40 .2', Post +59 .3, 40 .3', Post +71 .0, 40 .3', Post +82 .8, 40 .3', Post +94 .5, 40 .4', Post +98 .0, 49 .9', Ligh t P ole 39 +34 .9, 59 .9', Tree +52 .0, 33 .6', Hand h o le +56 .2, 40 .5', Mon u ment +61 .1, 59 .4', Pine Tree +68 .6, 72 .9', Ligh t P ole +71 .0, 49 .3', Post +92 .0, 44 .9', Reba r Fou n d 36 +11 .4, 60 .3', S prink ler Valve gr a s s +76 .5, 42 .4', Sprink ler Valve +22 .0, 47 .9', Sprink ler Valve +35 .6, 50 .1', Sprink ler Valve +41 .1, 59 .4', Sprink ler Valve grass Str. No. 325 Str. No. 326 Str. No. 328 Str. No. 327 870 870 Constr. Limits 124+63.91 "PR-RL1" END INCIDENTAL CONSTRUCTION Line "RL" P.O.T. 43+63.69 "RL" Constr. Limits Constr. Limits Constr. Limits Constr. Limits Constr. Limits 123+00 124+00 125+00 84 5 .7 84 6 .4 84 7 .2 84 7 .7 84 8 .1 84 8 .4 84 8 .5 T H C MON G H WV W V H H T MON FP H H H H PP S T PP S T TR H WV WV WV WV Ex. 832.97Ex. 832.96 Exist. 36" Pipe S tr . No . 3 2 4 E xis t . M. H. 1 2 3 + 5 7 . 9 Existing Ground Exist. 36" PipeExist. 36" Pipe 124+63.91 "PR-RL1" END INCIDENTAL CONSTRUCTION Exist. 30" PipeExist. 36" Pipe NRM TJM NRM RJCDRAWN: CHECKED:LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 1" = 30' 1" = 10' PLAN AND PROFILE FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PP.PR-RL1.04.dgn5/24/2021 09:43:26 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 27 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 3 0 3 5 820 810 800 790 840 For Proposed Drainage Structures, see Construction Details. All Topography Information Described from Line "S-1-A", Except as Noted. Line "PR-S1A" to be Constructed. All R/W Described from Line "PR-S1A", Except as Shown. NOTES: App. Exist. R/W App . Exist. R /W KRG CENTRE LLC ANITA L. NIX ROGER E. & ASSOCIATION INC HOMEOWNERS FAIRGREEN TRACE SPEEDWAY LLC 116th St. App. Section Line CARMEL CLAY PARKS BUILDING CORPORATION CORNER ASSOCIATES LP App. P.L. Ap p . P.L. Ap p . P .L. Ap p . P . L. App . P .L. App. Exist. R/W HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 1, T 17 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 6, T 17 N, R 4 EAp p . Se c ti o n Lin e App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W Ap p . Ex is t . R / W App. Exist. R/W (flowers) (gas pumps) conc. conc. conc. conc. con c. conc. con c. conc. con c. con c. conc. conc. con c. con c. conc. con c. conc. conc. grass grass grass grass grass grass grass grass grass grass grass grass grass grass grass grass grass grass gra ss grassstone asphalt asphalt asphalt asphalt asphalt asph alt asphalt asphalt asphalt asphalt asphalt planter planter planter plante r pla nter planter planter planter pla nter con c. asphalt asphalt asphalt asphalt conc. asphalt asphalt asphalt asphalt conc. con c. asph a lt con c. conc. (gas pumps) O/H Canopy O/H Canopy Ap p . Ex is t . R / W Ap p . Ex is t . R / W 1 5 .0 ' 25 .0 ' Ease m ent No Acc e ss FAIRGREEN TRACE, PHASE 2 BLOCK "A" COMMON AREA Blanket Utility & Drainage Easement Easement No Acc e ss 1 5 . 0 ' Easement S.D. & U. ASSOCIATION INC HOMEOWNERS FAIRGREEN TRACE 6" pvc 4" pv c 8" pvc3" pvc6" pvc 8" vcp8" pvc 30 " rcp 1 2 " rcp 12 " cpp 12" cpp 12" rcp 12 " rcp 15 " cpp 12 " rcp 8" pvc 12" rcp 15 " rcp 18" cpp 12" rcp 12" rcp 12 " rcp 12" rcp 12 " rcp 18" rcp 42 " rcp 4 2 " rc p 21" rcp 1 2" c p p 8" vcp 42 " rcp 8" vcp 6" vcp (brick Walgreens)14 +14 .0, 65 .1', Sa nit ary Manh o le +34 .0, 53 .0', Tree +43 .1, 0.8', Tree 14 +45 .7, 0.7', Ir on Pin Fou n d +51 .6, 70 .4', Tree +72 .0, 54 .6', Tree +77 .3, 53 .7', Be e hive Inlet +82 .8, 71 .3', Tree +84 .6, 75 .5', S ign +85 .0, 82 .6', S ign +99 .3, 36 .9', Inlet +99 .5, 40 .8', Drainage Ma nh o le 15 +00 .2, 35 .2', Inlet 15 +19 .5, 54 .7', Combina ti on P ole +34 .7, 62 .3', Mail bo x +37 .2, 53 .8', Guy Wire +40 .1, 53 .9', Guy Wire +44 .3, 88 .0', Tree +44 .6, 54 .3', Guy Wire +49 .7, 54 .1', Guy Wire +55 .2, 53 .7', Guy Wire +56 .6, 39 .1', Sign +59 .8, 53 .9', Guy Wire +73 .9, 51 .4', Post +80 .7, 54 .0', Sign +81 .1, 45 .3', Sign +82 .2, 68 .8', Guy Wire +82 .3, 57 .2', Combina ti on P ole +83 .6, 54 .4', Sign +84 .0, 45 .4', Sign +98 .6, 58 .1', Guy Wire 16 +00 .2, 41 .1', Mag Na il +00 .2, 41 .1', Mag Na il +10 .5, 56 .1', Ele c tric Meter Box +11 .9, 48 .6', Tree +14 .6, 43 .0', Guy Wire 16 +19 .0, 53 .1', Tree +19 .2, 43 .2', Guy Wire +19 .8, 53 .2', Transforme r +21 .1, 43 .6', Tele ph o n e Pedestal +22 .8, 42 .8', Guy Wire +24 .1, 43 .4', Guy Wire +25 .8, 52 .7', Mis c. MH +37 .2, 7.2', Te leph o n e Manh o le +37 .2, 48 .3', Sta nd p ipe +39 .4, 41 .6', Tele ph o n e Pedestal +42 .6, 43 .2', Combina ti on P ole +43 .9, 58 .6', Tree +53 .6, 46 .9', Tree +54 .4, 78 .6', Cle a no u t +54 .6, 86 .0', Tree +55 .8, 53 .6', Tree +58 .0, 41 .7', Water Valve +61 .4, 46 .0', Water Valve +75 .0, 34 .2', Inlet +75 .0, 32 .4', Inlet +85 .1, 74 .4', Tree +87 .1, 46 .3', Tree +87 .8, 51 .8', Tree 17 +09 .5, 72 .6', Ligh t P ole 17 +21 .5, 46 .5', Tree +23 .2, 48 .4', Tree +30 .2, 38 .3', Fire Hyd rant +30 .8, 72 .6', Tree +45 .0, 59 .2', Tree +58 .6, 68 .0', Sign +59 .3, 55 .9', Sign +62 .2, 76 .9', S ign +62 .2, 84 .3', S ign +62 .8, 87 .0', Inlet +95 .9, 66 .4', Sign +96 .6, 70 .0', Mon u ment +98 .6, 27 .4', Detec tor Hou sing 18 +07 .2, 46 .5', Tele ph o n e Pe destal +09 .8, 50 .8', C ATV Pe destal +11 .6, 85 .8', Inlet 18 +12 .0, 42 .2', Combina ti on P ole +13 .1, 33 .7', Hand h o le +15 .1, 42 .3', Tele ph o n e Pedestal +18 .0, 42 .4', Sprink le r Con trol Valve +19 .4, 25 .5', Dra ina ge Manh o le +21 .2, 32 .1', Inlet +21 .7, 32 .1', Inlet +23 .1, 34 .3', Sign +23 .4, 72 .3', Ligh t P ole +25 .7, 47 .4', Sign +28 .3, 55 .3', Tree +33 .8, 33 .8', S ign +36 .5, 90 .7', Post +36 .8, 43 .4', Mon u ment +36 .9, 78 .9', Post +60 .0, 56 .5', Tree +62 .8, 46 .5', Ligh t Pole +70 .6, 34 .3', Ligh t P ole +73 .1, 34 .2', Ligh t Pole +73 .4, 40 .1', Mag Na il +73 .4, 40 .1', Mag Na il +78 .7, 34 .2', S ign +97 .4, 56 .5', Tree 19 +05 .9, 46 .5', Guy Wire 19 +13 .2, 70 .5', Ga s Line Meter +15 .1, 56 .7', Ga s Valve +16 .4, 25 .0', Dra ina ge Manh o le +17 .1, 32 .1', Clea no u t +17 .2, 32 .2', Inlet +17 .6, 57 .2', Gas Line Marker +18 .2, 32 .1', Inlet +20 .5, 49 .9', Water Valve +21 .9, 33 .6', Hand h o le +22 .5, 46 .5', Combina ti on P ole +22 .7, 42 .8', Traff ic Pedestal +23 .0, 33 .3', Ha nd h o le +26 .5, 5.0', De te c tor Hou s ing +26 .6, 44 .8', Tele ph o n e Pedestal +28 .8, 44 .6', Combina ti on P ole +32 .5, 46 .1', Hand h o le +33 .0, 74 .2', Fire P lug +35 .6, 47 .8', Fire Hyd rant +37 .6, 73 .6', Water Valve +37 .9, 48 .1', Water Valve +38 .9, 48 .5', Ha nd h o le +43 .5, 58 .2', Ha nd h o le +44 .4, 55 .1', Traff ic Strain Pole +44 .6, 54 .2', Tra ff ic S train P ole +45 .5, 57 .8', CATV P edestal +51 .4, 54 .1', Water Valve +53 .5, 69 .4', Rebar F ou n d +54 .8, 56 .4', Mon u ment +63 .6, 27 .0', Tele ph o n e Manh o le +69 .1, 26 .6', Tele ph o n e Manh o le +13 .2, 23 .0', Dra ina ge Manh o le +15 .2, 72 .3', Dra ina ge Manh o le +30 .2, 73 .8', Ga s Valve +30 .9, 91 .9', Inlet +33 .5, 87 .7', Post +45 .5, 40 .1', Dra ina ge Manh o le 20 +46 .5, 74 .7', Well +46 .5, 61 .3', Mon u ment +46 .8, 51 .9', Mon u me nt +47 .7, 79 .5', Ha nd h o le +48 .9, 90 .6', Rebar Fou n d +49 .7, 73 .3', Traff ic Pe destal +51 .2, 61 .5', Hand h o le +52 .2, 92 .6', Ligh t P ole +52 .6, 56 .2', Traff ic Strain Pole +52 .6, 68 .2', Ligh t Pole +52 .8, 66 .7', Tra ff ic S train P ole +58 .3, 66 .1', Post +58 .8, 65 .0', Post +59 .9, 64 .5', Post +60 .8, 62 .4', Ha nd h o le +61 .7, 96 .4', Well +65 .6, 91 .5', Mis c. MH +66 .2, 81 .3', Mis c. MH +66 .7, 83 .0', Mis c. MH +66 .7, 85 .4', Mis c. MH +67 .5, 36 .7', Hand h o le +72 .3, 50 .4', Ligh t Pole +73 .0, 5.0', De te c tor Hou s ing +74 .4, 67 .6', Well +75 .2, 45 .8', Ha nd h o le +75 .3, 89 .5', Mis c. MH +75 .8, 80 .3', Mis c. MH +76 .1, 77 .4', Mis c. MH +77 .2, 66 .5', Mis c. MH +81 .7, 63 .6', Well +82 .1, 53 .0', Rebar Fou n d +86 .7, 59 .6', Well +88 .9, 89 .3', Post +89 .2, 74 .5', Post +90 .4, 86 .9', Post +90 .7, 77 .2', Post +92 .1, 89 .4', Post +92 .3, 74 .5', Post +41 .6, 44 .7', Comb. P ole +90 .3, 2.2', S prink ler Valve +21 .3, 58 .9', Sa n. Manh o le +21 .8, 37 .8', Sa n. Manh o le 830 2 0 + 0 0 asph alt 42 " rcp (1-sty brick) (1-sty block gas station) +57 .0, 42 .8', Sprink le r Va lve (1-sty brick/frame) (TBM#50) National Bank) El. 823.29 116th St. & 270'± W of � Rangeline Rd. (front of old TBM #50 - Chisled "X" on NNW Bolt of Fire Hydrant 38'± N of � Line "S-1-A" Lin e "R L" Line "S-1-A" & "PR-S1A" Lin e "PR-RL1" P.O.T. 17+63.03 "S-1-A" P.I. 33+63.03 "PR-S1A" = Line "PR-S1A" CURVE DATA P.I. = 36+75.13 "PR-S1A" T = 74.62' L = 145.03' R = 250.00' E = 10.90' S.E. = N.C. CURVE DATA P.I. = 108+56.97 "PR-RL1" T = 66.69' L = 131.64' R = 333.00' E = 6.61' S.E. = N.C. CURVE DATA P.I. = 106+87.87 "PR-RL1" T = 26.35' R = 333.00' E = 1.04' S.E. = N.C. L = 52.60' P.O.T. 30+00.00 "PR-S1A" P.O.T. 14+00.00 "S-1-A" = P.R.C. 106+61.52 "PR-RL1" 15+00 20+00 R a n g e Lin e R d . W e s tfie ld B lv d . Str. No. 343 Str. No. 347 Str. No. 308 Str. No. 400 Str. No. 307 Str. No. 306 Str. No. 305 Str. No. 312 Str. No. 310 820 810 800 790 840 830 gra s s Str. No. 344 Constr. Limits Constr. Limits R/W App. P.L. & R/W P . R . C . 1 0 9 + 2 1 . 9 2 "P R -R L1 " P.I. 108+56.97 "PR-RL1" R/ W 32+80.00 "PR-S1A" BEGIN CONSTRUCTION P.C. 33+31.06 "PR-S1A" P.R.C. 33+94.91 "PR-S1A" CURVE DATA P.I. = 33+63.03 "PR-S1A" T = 31.97' L = 63.85' R = 470.00' E = 1.09 S.E. = N.C. CURVE DATA P.I. = 34+98.11 "PR-S1A" T = 103.21' L = 205.61 R = 950.00' E = 5.56' S.E. = N.C. P.I. 34+98.11 "PR-S1A" P.I. 36+75.13 "PR-S1A" 43' +75P.L. (50.00') +07.79 43' +22 R/W R / W P .T. 1 0 7 + 1 4 .1 2 " P R - RL1 " P. I. 1 0 6 + 8 7 .8 7 " P R - RL1 " 54' +00 "PR-RL1" P.O.T. 19+90.00 "RL" P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = No Curve Run �=0°01'27" RT. P.I. 20+00.00 "S-1-A" No Curve Run �=1°36'10" LT. P.I. 20+00.00 "RL" = 59' +15 Str. No. 345 Str. No. 309 64' +07 56' +85 "PR-RL1" 50' +54 60' +54 RW(49.65') +54 59' +19 "PR-RL1" 64' +90 "PR-RL1"8" pvc 91' +97 Str. No. 342 Str. No. 348 S-MART REAL ESTATE, INC. Temp. R/W Temp. R/W Ap p . E x is t . R/ W T e m p . R / W Temp. R/W Ap p . P.L. & R/ W P.L.(56.13')"PR-RL1" +P.L.(+71.64) P.L.(82.74') +P.L.(+51.99) "RL" 59.29' +85.93 "RL" P.L.(50.00') +24.03 "RL" Str. No. 348A Str. No. 346 70' +05 "PR-RL1" 90' +25 "PR-RL1" R/W 75' +00 "PR-RL1" Temp. R/W 95' +20 "PR-RL1" MON LD LD LD GM PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST IPn MB MAG MAG MON MON MON MON W W W W W W W W W PPST PPST PPST PPST PPST RB-0 T H H H H H H H H CC-TR C WV WV WV WV CC-TR T H WV C WV H T H MON FFE PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST T T EM PPST RB-0 MAG MAG H T G PF 31+00 32+00 33+00 34+00 35+00 36+00 37+0030+00 82 7 .0 82 5 .6 82 4 .7 82 3 .7 82 2 .6 82 1 .6 82 0 .8 81 9 .9 81 9 .2 81 8 .9 81 8 .9 81 9 .4 81 8 .4 81 7 .3 8 2 1 . 6 5 8 2 0 . 7 6 8 1 9 . 9 0 8 1 9 . 4 1 8 1 9 . 4 0 8 1 9 . 1 0 P.G. EL. 822.00 32+80.00 "PR-S1A" BEGIN CONSTRUCTION Existing Ground Ex. 811.08Ex. 811.28 Exist. 18" Pipe Exist. 21" Pipe Exist. 12" Pipe S t r . N o . 3 0 8 1 0 8 + 2 4 . 7 "P R -RL1 " E xis t. M. H. See Roundabout Spot Elevations 130.00' V.C. P.V.I. EL. 819.00 P.V.I. 34+50.00 +0.751%-1.765%-2.479% P . V. I . EL . 8 1 9 . 5 0 P . V. I . 3 6 + 8 3 . 0 4 P . V. I . E L . 8 1 9 . 6 0 P . V. I . 3 5 + 2 9 . 8 7 Str. No . 3 4 8 M .H . 3 5 + 1 1 .0 813.95 813.55 46' of 12" Pipe @ -0.54% 812.12 S tr . No . 3 4 4 In le t 3 4 + 7 3 .0 S tr . No . 3 4 7 In le t 3 4 + 8 0 .0 812.15 26' of 15" Pipe @ -0.50%26' of 15" Pipe @ -0.50% S tr. N o . 3 4 3 M .H . 3 4 + 2 1 .0 815.00 814.20 6' of 12" Pipe @ -0.50% 3' of 15" Pipe @ -0.67% 813.70 813.68 7' of 18" Pipe @ -0.43% TJM NRM RJC NRM LINE "PR-S1A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 1" = 30' 1" = 10' PLAN AND PROFILE FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PP.PR-S1A.01.dgn5/24/2021 09:43:28 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 28 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 6, T 17 N, R 3 E For Proposed Drainage Structures, see Construction Details. All Topography Information Described from Line "S-1-A", Except as Noted. Line "PR-S1A" to be Constructed. All R/W Described from Line "PR-S1A", Except as Shown. NOTES: KRG CENTRE LLC App. Exist. R/W (brick Walgreens) Ap p . Ex is t . R / W SPEEDWAY LLC19 +13 .2, 70 .5', Ga s Line Meter +15 .1, 56 .7', Ga s Valve +16 .4, 25 .0', Dra ina ge Manh o le +17 .6, 57 .2', Gas Line Marker +18 .2, 32 .1', Inlet +20 .5, 49 .9', Water Valve +23 .0, 33 .3', Ha nd h o le +33 .0, 74 .2', Fire P lug +37 .6, 73 .6', Water Valve +38 .9, 48 .5', Ha nd h o le +43 .5, 58 .2', Ha nd h o le +44 .6, 54 .2', Tra ff ic S train P ole +54 .8, 56 .4', Mon u ment +49 .7, 73 .3', Traff ic Pe destal +52 .2, 92 .6', Ligh t P ole +52 .8, 66 .7', Tra ff ic S train P ole +60 .8, 62 .4', Ha nd h o le +73 .0, 5.0', De te c tor Hou s ing +74 .4, 67 .6', Well +75 .2, 45 .8', Ha nd h o le +82 .1, 53 .0', Rebar Fou n d 20 +46 .5, 74 .7', Well +51 .2, 61 .5', Hand h o le +52 .6, 56 .2', Traff ic Strain Pole +52 .6, 68 .2', Ligh t Pole +58 .3, 66 .1', Post +59 .9, 64 .5', Post +61 .7, 96 .4', Well +65 .6, 91 .5', Mis c. MH +66 .2, 81 .3', Mis c. MH +66 .7, 83 .0', Mis c. MH +66 .7, 85 .4', Mis c. MH +67 .5, 36 .7', Hand h o le +72 .3, 50 .4', Ligh t Pole +75 .8, 80 .3', Mis c. MH +76 .1, 77 .4', Mis c. MH +77 .2, 66 .5', Mis c. MH +81 .7, 63 .6', Well +86 .7, 59 .6', Well +88 .9, 89 .3', Post +89 .2, 74 .5', Post +92 .3, 74 .5', Post 116th St. App. Exist. R/W App. Exist. R/W 18" rcp App. Section Line 3 5 Ap p . P .L. Ap p . P . L. Ap p . P.L. 2" pv c6" pvc 42 " rcp 12 " rcp 8" pv c 8" pvc (gas pumps) (block ca r wash) con c. conc. con c. conc. conc. con c. conc. conc. conc. conc. conc. conc. conc. conc.grass grass gra ss gra ss gra s s grass grass grass grass grass grass grass grass grass asphalt asphalt asphalt asphalt asphalt asphalt asphalt a s p h a l t riprap planter planter mulch riprap 12 " rcp 12 " rcp grass asphalt 12 " rcp 12 " rcp con c. gra ss conc. grass planter 8" vcp 6" vcp 42 " rcp 21" rcp 4 2 " rcp 12" rcp (gas pumps) O/H Canopy conc. grass con c. 30 " rcp 8" pvc 1 2" rc p 12" rcp O/H Canopy conc. conc. conc. conc. asphalt asphalt asphalt 12 " rcp 12" rcp 12" cp p 48" rcp 12" rcp 12" rcp conc. 42" rcp 12" rcp 820 810 800 790 840 830 820 810 800 840 830 App. P.L. App. Exist. R/W App. Exist. R/WApp. Exist. R/W App. Exist. R/W App. Exist. R/W 4 0 asphalt as ph alt asph a lt HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 1, T 17 N, R 3 E +86 .7, 59 .6', We ll +90 .4, 86 .9', P os t +13 .2, 89 .6', P os t +16 .1, 89 .4', P os t 21 +20 .3, 52 .8', Ligh t P ole +21 .2, 34 .2', Ligh t Pole +21 .9, 59 .3', Mis c. MH +26 .0, 45 .2', Ligh t P ole +26 .2, 81 .1', Mis c. MH +26 .2, 83 .1', Mis c. MH +27 .8, 54 .6', We ll +27 .9, 99 .5', Inlet +28 .3, 77 .2', Misc. MH +35 .0, 75 .0', Unk n o wn Objec t +35 .2, 32 .8', Inle t +35 .9, 82 .9', Mis c. MH +36 .3, 64 .2', Mis c. MH +36 .3, 80 .8', Mis c. MH +36 .5, 74 .5', P os t +40 .1, 74 .6', P os t +43 .1, 91 .8', Misc. MH +44 .5, 86 .8', Misc. MH +45 .7, 83 .1', Mis c. MH +45 .8, 81 .0', Mis c. MH +46 .8, 65 .0', Mis c. MH +55 .1, 83 .4', Mis c. MH +55 .5, 64 .7', Mis c. MH +60 .7, 74 .7', P os t +61 .4, 89 .2', Mis c. MH +63 .2, 23 .8', Sanit ary Ma nh o le +64 .2, 89 .9', P os t +64 .3, 43 .4', Inlet +66 .7, 53 .5', Ligh t P ole +69 .4, 45 .4', Sign +81 .7, 74 .0', We ll +88 .2, 68 .4', Mon u ment +89 .7, 51 .1', Inlet +90 .4, 32 .7', Inle t +98 .1, 35 .2', S ign 22 +06 .9, 57 .9', Sign +06 .9, 64 .4', Ligh t Pole +07 .0, 49 .3', S ign 22 +07 .8, 38 .3', Dete c tor Hou sing +07 .9, 39 .1', Dete c tor Hou sing +09 .4, 45 .7', Rebar Fou n d +16 .1, 63 .1', Sign +16 .3, 54 .8', Sign +24 .7, 45 .5', Hand h o le +24 .9, 43 .3', Inlet +40 .5, 71 .8', Tree +52 .3, 55 .4', Guy Wire +52 .6, 52 .2', Re ba r Fou n d +52 .6, 72 .2', Combina ti on P ole +52 .8, 60 .2', Guy Wire +53 .7, 57 .3', Guy Wire +54 .1, 64 .5', Te leph o n e P edestal +54 .1, 62 .8', Te leph o n e P edestal +55 .2, 54 .4', Guy Wire +60 .5, 44 .9', Guy Wire +61 .0, 55 .8', Guy Wire +61 .3, 53 .7', Guy Wire +62 .6, 64 .7', Combinati on Pole +63 .4, 43 .8', Sign +68 .6, 58 .9', Guy Wire +68 .9, 46 .2', Combinati on Pole +69 .4, 63 .0', Guy Wire +69 .9, 59 .4', Guy Wire +72 .7, 92 .9', Hand h o le +74 .7, 92 .5', Uti l i t y Line Marke r +76 .5, 75 .9', Hand h o le +78 .6, 79 .1', Combina ti on P ole +84 .1, 45 .0', Guy Wire +88 .3, 34 .1', Ligh t Pole +91 .1, 43 .1', Gas Line Marker +99 .2, 46 .1', Rebar Fou n d 23 +04 .7, 45 .3', Sign +04 .9, 53 .5', S ign +06 .3, 36 .5', Gas Valve +07 .3, 40 .1', Mag Nail 23 +31 .4, 50 .6', Mon u me nt +54 .5, 33 .0', Inlet +58 .1, 36 .3', Sign +58 .7, 21 .0', Dra ina ge Ma nh o le +62 .8, 29 .0', Inle t +77 .8, 81 .5', Sign 24 +14 .4, 80 .8', Sign +25 .1, 37 .7', Tree +31 .3, 58 .2', Water Valve +34 .3, 37 .8', Tree 24 +41 .1, 35 .4', Misc. P ole +41 .2, 35 .4', Combinati on Pole +42 .9, 61 .9', Guy Wire +43 .0, 54 .2', Mis c. P ole +43 .1, 54 .2', Mis c. P ole +43 .9, 38 .4', Tree +64 .4, 35 .5', Ligh t P ole +94 .3, 31 .9', Mail bo x +98 .2, 24 .2', Mon u ment 25 +03 .1, 31 .2', Tree +24 .8, 35 .6', Tre e PROPERTY GROUP LLC MILLER McCOMAS KAREN C BROWN CHARLES M &DANETTE M. ROLAND WOODLAND SHOPPES Lot 1 WOODLAND GOLF CLUB SUBDIVISION 30.0' 20.0' Easement Utility Easement Utility 790 42 " rcp (1-sty block gas station) 21 +06 .9, 35 .6', Dra ina ge Mh. +16 .2, 42 .6', Tele. P ole +20 .8, 44 .0', Comb. Pole +18 .0, 43 .8', Elec . P edestal +32 .7, 43 .4', Elec . Meter Box +34 .8, 43 .1', Elec . Meter Box Lin e "PR-RL1" 2 0 + 0 0 Line "PR-S1A" Lin e "R L" Line "S-1-A" asphalt Line "S-1-A" & "PR-S1A" P.O.T. 42+04.12 "PR-S1A" P.O.T. 26+00.00 "S-1-A" = P.R.C. 37+45.54 "PR-S1A" CURVE DATA P.I. = 108+56.97 "PR-RL1" T = 66.69' L = 131.64' R = 333.00' E = 6.61' S.E. = N.C. CURVE DATA P.I. = 106+87.87 "PR-RL1" T = 26.35' R = 333.00' E = 1.04' S.E. = N.C. L = 52.60' 25+0020+00 +46 .8, 51 .9', Mon . R a n g e Lin e R d . W e s tfie ld B lv d . Do Not Disturb Pipe Str. No. 348 Str. No. 400 Str. No. 308 Str. No. 402 Str. No. 355 Str. No. 357 Str. No. 356 Str. No. 354 Str. No. 351 Str. No. 349 Ap p . E x is t . R/ W Constr. Limits App. P.L. & R/W P.I. 108+56.97 "PR-RL1" Str. No. 305 P.R.C. 106+61.52 "PR-RL1" Ap p . Ex is t . R / W +13 .2, 23 .0', Dra ina ge Manh o le +15 .2, 72 .3', Dra ina ge Manh o le +30 .2, 73 .8', Ga s Valve +30 .9, 91 .9', Inlet +33 .5, 87 .7', Post +45 .5, 40 .1', Dra ina ge Manh o le +46 .5, 61 .3', Mon u ment +47 .7, 79 .5', Ha nd h o le +48 .9, 90 .6', Rebar Fou n d P . R . C . 1 0 9 + 2 1 . 9 2 "P R -R L1 " con c.gra s s P.L.(50.42') +P.L.(+03.34) CURVE DATA P.I. = 36+75.13 "PR-S1A" T = 74.62' L = 145.03' R = 250.00' E = 10.90' S.E. = N.C. CURVE DATA P.I. = 34+98.11 "PR-S1A" T = 103.21' L = 205.61 R = 950.00' E = 5.56' S.E. = N.C. CURVE DATA P.I. = 38+08.54 "PR-S1A" T = 63.00' L = 125.34' R = 500.00' E = 3.95' S.E. = N.C. P.O.T. 19+90.00 "RL" P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = App. Exist. R/W R/W 54' +00 "PR-RL1" 19 +05 .9, 46 .5', Guy Wire +17 .1, 32 .1', Clea no u t +17 .2, 32 .2', Inlet +21 .9, 33 .6', Hand h o le +22 .5, 46 .5', Combina ti on P ole +22 .7, 42 .8', Traff ic Pedestal +26 .5, 5.0', De te c tor Hou s ing +26 .6, 44 .8', Tele ph o n e Pedestal +28 .8, 44 .6', Combina ti on P ole +32 .5, 46 .1', Hand h o le +35 .6, 47 .8', Fire Hyd rant +37 .9, 48 .1', Water Valve +44 .4, 55 .1', Traff ic Strain Pole +45 .5, 57 .8', CATV P edestal Ap p . Ex is t . R / W +51 .4, 54 .1', Water Valve +53 .5, 69 .4', Rebar F ou n d +63 .6, 27 .0', Tele ph o n e Manh o le +69 .1, 26 .6', Tele ph o n e Manh o le P. I. 1 0 6 + 8 7 .8 7 " P R - RL1 " P .T. 1 0 7 + 1 4 .1 2 " P R - RL1 " Ap p . Se c ti o n Lin e P.I. 34+98.11 "PR-S1A" P.I. 36+75.13 "PR-S1A" Str. No. 307 39+55.00 "PR-S1A" END CONSTRUCTION P.T. 38+70.88 "PR-S1A" P.O.T. 22+03.76 "S-1-A" P.I. 38+08.54 "PR-S1A" = 56' +85 "PR-RL1" Str. No. 306 59' +15 64' +07 Str. No. 350 Str. No. 352 Str. No. 358 asphaltStr. No. 353 P.L.(54.68') +25 70' +25 91' +97 59' +19 "PR-RL1" Str . N o . 3 1 2 64' +90 S-MART REAL ESTATE, INC. Temp. R/W R / W P.L.(56.13')"PR-RL1" +P.L.(+71.64) No Curve Run �=0°01'27" RT. P.I. 20+00.00 "S-1-A" No Curve Run �=1°36'10" LT. P.I. 20+00.00 "RL" = T e m p . R / W Ap p . P.L. & R/ W Str. No. 310 Temp. R/W Temp. R/W Str. No. 309 P.L.(82.74') +P.L.(+51.99) "RL" 59.29' +85.93 "RL" P.L.(50.00') +24.03 "RL" 3" pvc - forcemain grassgrass 3" pv c - force main P.L.(52.35') +P.L.(+58.05) Do Not Disturb Sign Tank Caps & Light Pole Do Not Disturb Wells, Str. No. 348A Ap p . P .L. R/W R/W R/W 70' +05 "PR-RL1" 90' +25 "PR-RL1" 44' +40 P.L.(40.39') +00 Ap p . P .L. LLC. COYOTE ENTERPRISES, 75' +00 "PR-RL1" 95' +20 "PR-RL1" Temp. R/W 50' +40 P.L.(42.21') +07.94 47' +07.19 LD LDLD LD EM EME GM PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST MB MAG MON MON MON MON MON MON W W W W W W W W W W W W W PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST RB-0 T T H H H H H H H H H CC-TR WV WV WV CC-TR T H WV C WV H RB-0 G PZZZ H H H T G PF 35+00 36+00 37+00 38+00 39+00 40+00 41+00 42+00 81 8 .9 81 8 .9 81 9 .4 81 8 .4 81 7 .3 81 6 .9 81 7 .1 81 7 .7 81 8 .6 81 9 .7 82 0 .8 82 1 .9 82 2 .5 8 1 9 . 4 0 8 1 9 . 1 0 8 1 8 . 2 4 8 1 7 . 8 8 8 1 8 . 0 3 8 1 8 . 6 9 8 1 9 . 7 2 Profile Grade P.G. EL. 819.81 39+55.00 "PR-S1A" END CONSTRUCTION Ex. 811.08Ex. 811.28 Exist. 18" Pipe Ex. 811.74 Exist. 21" Pipe S t r . N o . 3 0 8 1 0 8 + 2 4 . 7 "P R -RL1 " E xis t. M. H. Exist. 21" Pipe S t r. N o . 3 5 1 M .H . 3 7 + 0 9 .0 810.99 +46.4 811.24 +67.1 (Downstream) Remain in Place Exist. 48" RCP to (Upstream) Remain in Place Exist. 48" RCP to See Roundabout Spot Elevations 225.00' V.C. P.V.I. EL. 816.60 P.V.I. 38+00.00 +0.751%-2.479% P . V. I . EL . 8 1 9 . 5 0 P . V. I . 3 6 + 8 3 . 0 4 P . V. I . E L . 8 1 9 . 6 0 P . V. I . 3 5 + 2 9 . 8 7 +2.077% Existing Ground Str. No . 3 4 8 M .H . 3 5 + 1 1 .0 Str. No . 3 5 4 In le t 3 8 + 0 7 .0 Str. No . 3 5 6 In le t 3 8 + 1 3 .0 813.55 812.12 Ex. 811.53 S t r . N o . 3 5 2 M. H. 3 7 + 7 3 . 2 812.67812.66 812.50 812.85 S t r . N o . 3 5 8 M. H. 3 8 + 4 7 . 0 33' of 12" Pipe @ 0.55% 32' of 12" Pipe @ 0.50% 812.15 26' of 15" Pipe @ -0.50% 814.50 812.25 7' of 18" Pipe @ -0.43% TJM NRM RJC NRM LINE "PR-S1A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 1" = 30' 1" = 10' PLAN AND PROFILE FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PP.PR-S1A.02.dgn5/24/2021 09:43:29 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 29 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 1 0 1 5 L = 60.19' CURVE DATA T = 30.24' P.I. = 11+50.96 "PR-S2A" R = 250.00' E = 1.82' S.E. = N.C. CURVE DATA T = 20.14' L = 40.20' P.I. = 13+28.94 "PR-S2A" R = 250.00' E = 0.81' S.E. = N.C. HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E 820 810 800 840 830 840 820 810 800 830 El. 829.45 of Intersection Medical Dr. & 40'± W of � Rangeline Rd. TBM #52 - Chisled "X" on E most Bolt of Fire Hydrant at NW Cor. For Proposed Drainage Structures, see Construction Details. Line "PR-S2A" to be Constructed. All R/W Described from Line "PR-S2A", Except as Shown. NOTES: (woo d ga te ) (brick CVS) (Autozone) (1-sty block) con c. c o n c. con c. con c. conc. conc. conc. conc. conc. conc. conc. conc. grass grass grass grass grass grass asphalt asphalt asphalt asphalt asphalt asph alt asphalt planter planter pla nter planter planter brick 12" vcp 10 " vcp 6" pv c 10" vcp 12" vcp 30" rcp 30" rcp 12 " rcp 12 " rcp 12" rcp8" cpp 12" rcp 36 " rcp 12" rcp 36 " rcp 30" rcp 30" rcp 10 +64 .4, 23 .0', Tree 10 +71 .0, 33 .2', S ign +71 .2, 17 .8', Ligh t P ole +74 .1, 31 .7', Ligh t P ole +82 .5, 30 .8', Ha nd h o le +87 .2, 24 .4', Tree +89 .8, 26 .8', Tree +95 .8, 24 .8', Ligh t P ole 11 +08 .6, 24 .2', Tree 11 +10 .4, 25 .9', Tre e +30 .0, 24 .8', Tree +36 .2, 24 .0', Tree +47 .1, 20 .9', Ligh t P ole +50 .6, 18 .8', Ligh t P ole +56 .3, 52 .9', Ligh t P ole +58 .3, 27 .6', S ign +60 .1, 21 .4', Tree +69 .2, 28 .7', S ign +70 .1, 85 .7', Tree +70 .7, 61 .4', Inle t +72 .7, 45 .5', Dra ina ge Manh o le +76 .9, 47 .5', Ligh t P ole +77 .9, 57 .7', Ha nd h o le +79 .1, 31 .9', Traff ic S train P ole +84 .8, 26 .1', Fire Hyd rant +86 .3, 47 .1', Clea no u t +87 .7, 27 .9', Water Valve +90 .7, 51 .9', Water Valve +91 .3, 25 .2', Water Me te r +92 .7, 50 .5', Inle t +94 .9, 5.4', Detec tor Hou sing +96 .0, 15 .0', Water Valve 12 +05 .2, 60 .9', Tre e +12 .4, 38 .4', Mon u m ent +13 .4, 33 .8', Ha nd h o le +17 .9, 94 .3', Te leph o n e P edes tal +25 .7, 91 .2', Ha nd h o le 12 +56 .6, 52 .4', Dra ina ge Manh o le +63 .4, 80 .1', Tree +64 .6, 33 .7', Traff ic P edes tal +64 .9, 6.5', Sa nit a ry Manh o le +65 .3, 73 .5', Bush +65 .7, 64 .9', Tree +66 .8, 19 .7', Mon u m ent +67 .2, 55 .9', Inle t +69 .3, 25 .0', Traff ic S train Pole +70 .5, 93 .4', G as Va lve +71 .2, 20 .9', Ha nd h o le +72 .4, 54 .1', S prink ler Con trol Valve +74 .9, 94 .9', S prink ler Con trol Valve +75 .5, 31 .5', Bush +75 .9, 34 .5', Bush +76 .1, 43 .0', Traff ic S train P ole +76 .7, 75 .8', Tree +82 .1, 32 .1', Ha nd h o le +84 .4, 26 .3', Tree +86 .8, 17 .6', Bush +89 .8, 28 .2', Ha nd h o le +91 .0, 17 .8', De te c tor Hou s ing +91 .0, 31 .4', Ligh t P ole +91 .4, 31 .7', Ligh t P ole +94 .2, 26 .9', Tree 13 +11 .4, 63 .8', Bee hive Inlet 13 +31 .8, 21 .5', Tree +33 .4, 25 .2', Bush +46 .3, 25 .4', Tree +52 .0, 89 .3', P ost +52 .1, 94 .7', P ost +52 .3, 99 .5', P ost +63 .1, 24 .5', Tree +64 .6, 54 .6', Water Valve +72 .2, 18 .0', Tree +77 .9, 23 .9', Bush +79 .0, 68 .2', Bee hive Inlet +81 .3, 23 .8', Bush +83 .6, 17 .8', S ign 14 +11 .7, 34 .3', Fire P lug 14 +12 .0, 35 .1', Ligh t P ole +12 .9, 31 .9', Water Valve +13 .5, 30 .2', Tree +15 .2, 23 .3', S prink ler Con trol Valve +15 .4, 21 .0', S prink ler Con trol Valve +17 .1, 19 .5', Tree +23 .6, 29 .4', Mon u m ent +24 .9, 19 .9', S prink ler Con trol Valve +36 .1, 33 .0', Hos e Bib +39 .6, 68 .0', Bee hive Inlet +48 .5, 32 .5', S ign +54 .4, 36 .1', Drainage Manh o le +58 .8, 87 .5', Drainage Manh o le +60 .0, 12 .7', Water Valve +60 .9, 26 .5', Water Valve +64 .4, 45 .9', Bush +64 .4, 42 .2', Tree +67 .6, 32 .9', Bush +68 .8, 15 .2', Drainage Manh o le +70 .8, 25 .2', Water Valve +74 .2, 55 .9', Bush +77 .9, 72 .5', Combinati on Pole +77 .9, 58 .5', G uy Wire +78 .3, 56 .7', G uy Wire +78 .6, 60 .3', Bush +81 .0, 34 .6', S ign +81 .8, 36 .4', S ign +82 .3, 43 .2', C ombinati on P ole +87 .3, 30 .6', Tree +87 .6, 43 .6', G uy Wire +90 .2, 57 .9', Mon u m ent +92 .4, 30 .9', Tree +99 .9, 39 .2', Water Me te r P.O.T. 10+00.00 "PR-S2A" N 90°00'00" E Line "PR-S2A" N 89°49'07" E P.O.T 14+00.00 "S-2-A" P.O.T. 15+00.00 "PR-S2A" N 89°49'07" E Line "PR-S2A" &"S-2-A"Line "S-2-A"Line "S-2-A" Ap p . S e c t i o n Lin e Ap p . Exis t. R / W Ap p . E xis t. R / W II COMPANY BARNES INVESTMENTS AUTOZONE INC Medical Dr. Ap p . E x is t . R/ W Ap p . E xist. R/ W KRG CENTRE LLC Ap p . P.L. Ap p . P. L. gras s 12 " cpp grass grass con c. grass gras s a sph a lt as ph alt grass grass a sph a lt asph alt R a n g e Lin e R d . gra s s conc. 8" pv c 30.0'Utility Easement asphalt asphalt TBM#52 12 " vcp P.C. 11+20.72 "PR-S2A" P.O.T. 10+95.21 "S-2-A" P.I. 13+28.94 "PR-S2A"= P.T. 11+80.91 "PR-S2A" No Curve Run �=22°49'37" LT. P.I. 12+25.69 "PR-S2A" = 10+00 P.O.T. 10+00.00 "S-2-A" P.O.T. 26+75.74 "RL" = P.O.T. 114+77.31 "PR-RL1"= 1 1 5 + 0 0 P.C. 13+08.79 "PR-S2A" P.T. 13+48.99 "PR-S2A" 10+90.00 "PR-S2A" BEGIN CONSTRUCTION P.O.T. 12+32.76 "PR-S2A" P.O.T. 114+61.91 "PR-RL1"= P.I. 11+50.96 "PR-S2A" Str. No. 504 Str. No. 505Str. No. 503 Str. No. 501 Str. No. 518 Str. No. 519 Str. No. 520 Str. No. 521 Str. No. 511 Str. No. 508 Str. No. 512 14+06.00 "PR-S2A" END CONSTRUCTION Lin e "RL" & "P R -R L1 " 6" steel grass con c. grass gra ss con c. overhang conc. Str. No. 509 Str. No. 510 790790 91°01'55" 81°49'06" Str. No. 401B Str. No. 506 Str. No. 507 Constr. Limits Constr. Limits Constr. Limits Constr. Limits Str. No. 502 Temp. R/W Temp. R/W Temp. R/W Temp. R/W R/ W R/ W R/W R/W 28' +90 35' +28 34' +90 70' +15 "PR-RL1" P.L. (45') +34 "PR-RL1" 45.45' +15.99 "PR-RL1" 14.76' +06 31' +06 55' +96 35' +30 32' +18 61' +09 "PR-RL1" 63' +05 "PR-RL1" 48' +05 "PR-RL1" 45' +09 "PR-RL1" Te m p . R / W R/W +90 .5, 18 .6', S prink le r Va lve T e m p . R/ W R/W Temp. R/W R/W 23' +18 Temp. R/W 24' +18 P.L. (45') +27 "PR-RL1" 63' +15 "PR-RL1" 38' +17 App. Exist. R/W App. Exist. R/W 70' +37 "PR-RL1" 60' +24 "PR-RL1" P.L. (45') +89 "PR-RL1" 65' +80 "PR-RL1" 52' +89 "PR-RL1" 47' +80 "PR-RL1" 52' +97 "PR-RL1" 49.50' "PR-RL1" +99.50 P.L.(36.07') +25 T e m p . R/ W Temp. R/W 41.79' +25 35' +96 55' +55 63' +55 63' +85.21 Temp. R/W Constr. Limits LD LD H H H H PPST PPST PPST PPST MON MON MON MON T H H CC-TR C WM WM WV WV WV WV WV WV WV WV RB-0 H B PZZZ PZZZ PZZZ PZZZ H H MON PPST MON PPST PPST PPST PPST F P 11+00 12+00 13+00 14+00 15+00 8 2 8 .5 8 2 7 .4 8 2 6 .0 8 2 6 .1 8 2 6 .4 8 2 5 .8 8 2 5 .6 8 2 5 .1 8 2 4 .3 8 2 3 .7 10+00 Existing Ground 10+90.00 "PR-S2A" BEGIN CONSTRUCTION 14+06.00 "PR-S2A" END CONSTRUCTIONSee Roundabout Spot Elevations Exist. 12" San. Sewer Pipe Ex. 808.52Ex. 809.17 1 4 + 6 8 .8 E xis t . S a n . M. H. Str. No. 401B Exist. San. M.H. 114+60.1 "PR-RL1" LINE "PR-S2A"NRM TJM NRM RJC BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 1" = 30' 1" = 10' PLAN AND PROFILE FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PP.PR-S2A.01.dgn5/24/2021 09:43:30 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 30 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 HAMILTON COUNTY CLAY TOWNSHIP SEC. 1, T 17 N, R 3 E GRAHAME D. & DIANA J. CURTS 21" rcp C ar m el C k.grass asphalt conc.(1-sty brick/frame) HAMILTON COUNTY CLAY TOWNSHIP SEC. 6, T 17 N, R 4 E ASSOCIATION INC HOMEOWNERS CREEKSIDE asphalt conc. 192" cmp asphalt asphalt conc. 12" rcp 12" rcp 42" rcp grass CORNER ASSOCIATES LP asphalt co n c. asphalt (1-sty brick) grass grass conc. grass conc. asphalt grass conc. grass grass 42" rcp conc. conc.grass O/H Canopy (gas pumps) asphalt (1-sty block gas station) grass 1 0 5 asphalt con c. 104+00.00 "PR-RL1" BEGIN PROJECT grass asphalt P.C. 106+08.38 "PR-RL1" R 15 15 13 15 15 K CURVE DATA P.I. = 106+87.87 "PR-RL1" T = 26.35' R = 333.00' E = 1.04' S.E. = N.C. L = 52.60' CURVE DATA S.E. = N.C. P.I. = 106+34.97 "PR-RL1" E = 0.69' R = 510.00' L = 53.14' T = 26.60' A A Westfield Blvd. Adjust Casting to Grade Str. No. 300 + 56 .6 RT. + 9 8 . 8 L T . Class III Drive Req'd. W = 24.0' C1 +80.0 RT. 5' of 12" Pipe Req'd Inlet, Type "J-10" & Str. No. 302 Str. No. 303 + 80 .0, 40.5' RT. + 79 .0 RT. + 4 8 . 3 , 4 3 . 5 ' R T . Str. No. 306 + 86 .0 LT . Str. No. 304 A A R1 R1 28.90' RT. +75.00 29.00' LT. +75.00 4.41' LT. +40.00 5.60' RT. +40.00 Str. No. 305 26' of 12" Pipe Req'd Manhole, Type "C-10" & Ap p . P .L. App. Exist. R/W 70' R/W Flo w App. Exist. R/W App. Section Line App. Exist. R/W App. P.L. App. Exist. R/W Line "PR-RL1" Line "PR-RL1" App. Exist. R/W R/W 50' R/W Constr. Limits Constr. Limits F Constr. Limits 15 F 15 A X1 + 1 6 . 4 F 22 14 24.00' RT. +54.88 F X3 conc. F 30.21' LT. +40.00 K X2 30.68' RT. +40.00 K 1613 T P.T. 107+14.12 "PR-RL1" P.I. 106+87.87 "PR-RL1" A R/W R/W P.R.C. 106+61.52 "PR-RL1" 38.00' RT. +76.9931.00' RT. +54.88 5.00' LT. +91.11 (Connect to Exist. Pipes) 4' of 42" Pipe Req'd Manhole, Type "K-4" & 30.00' RT. +77.11 R/W 3 0 '- 0 " 2 4 '- 0 " 5 '-0 " 5 '-0 " 5'-0" 5 '- 0 " 6 '-0 " 90°0'0" 6'-0" 5 '-0 " 6 '- 0 " 29'-0" 5'-0" 6'-0" 13 & Adjust Casting to Grade Flat Casting Req'd, Furnish Temp. R/W Temp. R/W 74' of 12" Pipe Req'd Manhole, Type "C-10" & Str. No. 303A 43' of 12" Pipe Req'd Inlet, Type "J-10" &+ 4 5 . 0, 5 3 . 5' L T. COYOTE ENTERPRISES, LLC. 5.00' RT. +91.11 20'R 20'R 20' R 4 4 A p p . P. L. R/W R/W R/W R/W S-MART REAL ESTATE, INC. Ap p . P .L. Temp. R/W P.I. 106+34.97 "PR-RL1" Class III Drive Req'd. W = 33.5' + 2 7 . 6 91°4'38" PR-RL1) (Tan. to 10' R Future Drive Entrance C1 and Adjust to Grade Casting, 13, Furnish Str. No. 301 E = 1 0 . 9 0 S . E . = N . C . W W W WW W W W W W H H H W V GM G M MB W V C W V H T LEGEND Full Depth HMA Pavement (See Typical Sections) F1 K X T PCCP Truck Apron (See Typical Sections) C C1 F Sidewalk, Concrete, 4 In. (See Carmel Std. Dwg. 10-18) K1 HMA for Approaches (Full Depth Pavement) R 28A Mill 1.5 in. & Resurface R1 HMA Wedge & Level (See Typical Sections) 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D Roll Curb for Truck Apron (See City of Carmel Std. 10-25C) Widening with PCC Base, 6" (See Typical Sections) HMA For Structure Installation, Type C (Full Depth Pavement) Widening with HMA, Typc C (Full Depth Pavement) Raised Pedestrian Crossing (See Miscellaneous Details) PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on Subgrade Treatment Type II 14 Straight Concrete Curb, Modified Curb Ramp, Concrete (See Curb Ramp Details) Shared-Use Path (See Typical Sections) 17 Curb & Gutter, Concrete, Type III 4 Planting Areas (See Landscape Plans) CONSTRUCTION DETAILS LINE "PR-RL1" RJCTJM NRM NRM 1"=20' N/A BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 31 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CD.PR-RL1.01.dgn5/24/2021 09:43:32 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 asphalt con c. gra ss asphalt conc. conc.42" rcp grass (gas pumps) HAMILTON COUNTY CLAY TOWNSHIP SEC. 1, T 17 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 6, T 17 N, R 4 E CORNER ASSOCIATES LP CURVE DATA P.I. = 108+56.97 "PR-RL1" T = 66.69' L = 131.64' R = 333.00' E = 6.61' S.E. = N.C. 42" rcp Ap p . S e c ti o n Lin e App . Exis t. R / W gra s s con c. 2" pvc 6" pvc 3" pvc Ap p . Exis t. R / W SPEEDWAY LLC conc. asphalt gra ss con c. con c. 21 " rcp as ph alt 1 1 6 th S t . asph a lt a sph alt 12 " rcp asph alt grass gras s 12" rcp 12 " rcp (brick Walgreens) KRG CENTRE LLC HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E 6" vcp 8" vcp conc. grass App. Exist. R/W12" rcp 42" rcp asphalt conc. grass Ap p . Exis t. R / W HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E Lin e "PR -S 1 A" P.I. 109+60.52 "PR-RL1" 12 " rcp 12 " rcp conc. conc. 12" rcp 12" rcp 12 " rcp 12" rcp gra s s asphalt asphalt conc. 21" rcp asphalt 12" vcp to 12" cpp12" pvcbrick conc. grass grass 24 " rcp 42" rcp 36" rcp Range Line Rd. grass grass asphalt conc. grass 12" vcp grass con c. aspha lt App. Exist. R/W App. Exist. R/W 8" vcp con c. 6" pvcgrass 8" p v c8" vcp 30 " rcp 8" pv c 30" rcp 8" pvc 8" pvc Ap p . P .L. 35.0'Ap p . P .L. S H O P P E S W O O D L A N D ACQUISITION CORPORATION VCA REAL PROPERTY grass aspha lt con c. (2-sty stone) gra s s asphalt Ap p . P.L. (Autozone) conc. con c. Line "PR-RL1" P.R.C. 109+21.92 "PR-RL1" 12" cpp App. Section Line K K R R 13 13 15 15 � ROUNDABOUT T 16 13 F1 Ap p . Ex is t. R / W CURVE DATA P.I. = 109+60.52 "PR-RL1" T = 38.60' L = 77.05' R = 510.00' E = 1.46' S.E. = N.C. 1 1 0 A A F1 29 '-0" 2 9 '-0 " 90°0'0" 90°0'0" 90°0'0" + 9 1 .1 + 9 3 .3 W = 35.7' Class III Drive Req'd. W = 28.0' Str. No. 316 Str. No. 401 Adjust Casting to Grade Str. No. 315+ 34.0 RT. Adjust Casting to Grade Str. No. 314 + 3 1 . 6 L T. + 6 3 . 9 L T. Adjust Casting to Grade Str. No. 317 C1 C1 Str. No. 346 See Line "PR-S1A" Str. No. 344 See Line "PR-S1A" Str. No. 307 Str. No. 349 See Line "PR-S1A" See Line "PR-S1A" Str. No. 402 See Line "PR-S1A" Str. No. 350 Str. No. 312 + 9 8 . 0 R T. Str. No. 310 +80.0 LT. F1 F 8 '- 0 " 5 '- 0 " 8 '- 0 " F1 A 13 15 See Line "PR-S1A" Str. No. 347 See Line "PR-S1A" Str. No. 345 App. Exist. R/W (gas pumps) Str. No. 308 13 A 6. 5' R T. + 7 3 . 1, + 30 .6, 36 .7' RT. Constr. Limits Constr. Limits asph alt 6'- 0"5'-0" R/W Ap p . P.L. & R/ W App. P.L. & R/W App. Exist. R/W 15A A 5 '- 0 " App. Exist. R/W 8'-0" P.T. 109+98.97 "PR-RL1" 13.9' RT. +34. 2, 15 + 9 9 .0 29.00' RT. +66.20 6.68' RT. +50.00 27.53' LT. +50.00 6.49' LT. +50.00 C1 29'-0" PR-RL1") (Tan. to Adjust Casting to Grade Str. No. 309 W = 54.1' + 2 6 . 6 X6 P.I. 36+75.13 "PR-S1A" 6'-0" P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = O.P.O.C. 36+08.35 "PR-S1A", 7.94' RT. O.P.O.T. 107+80.65 "PR-RL1", 5.81. RT. = conc. INC AUTOZONE P.T. 107+14.12 "PR-RL1" 37'-0" 10'-0" 29'-0" X9 F X8 X7 X4 X5 8'-0" 6'-0" F1 X12 X11 X10 App. Exist. R/W +67.0, 42.3' RT. 90°0'0" P .I . 3 4 + 9 8 .1 1 " P R - S1 A" CURVE DATA P.I. = 34+98.11 "PR-S1A" T = 103.21' L = 205.61' R = 950.00' E = 5.59' S.E. = N.C. 13 13 K 15 13 15 13 K K 5'-0" 6'-0" R/W 14 A Constr. Limits R/ W See Line "PR-S1A" Str. No. 348 7.2' RT. + 24 .7, Str. No. 400 37.7' RT.+43.8, See Line "PR-S1A" Str. No. 351 9.00' LT. +71.11 2 LFT Reconstruct Manhole & Adjust Casting to Grade Flat Casting Req'd, Furnish32' of 12" Pipe Req'd Inlet, Type "R-13" & 41' of 12" Pipe Req'd Inlet, Type "J-10" & To Remain As Is To Remain As Is Str. No. 401A Str. No. 317A+ 55 .9, 14 .8' RT. Temp. R/W Temp. R/W Temp. R/W Manhole 2 LFT Reconstruct Manhole 2 LFT Reconstruct 9.00' RT. +70.11 30.00' LT. +77.00 30.00' RT. +78.00 T e m p . R/ W 2 1 '-0 " 1 8 '- 0 " 2 1 '- 0 " 3.00' LT. +96.0 24.00' LT. +96.0 3.00' RT. +96.0 24.00' RT. +96.0 con c.overhang 30.00' LT. +11.79 9.00' LT. +11.79 28.17' RT. +50.00 6.44' RT. +47.56 CURVE DATA P.I. = 36+75.13 "PR-S1A" T = 74.62' L = 145.03' R = 250.00' E = 10.90' S.E. = N.C. & Adjust Casting to Grade Flat Casting Req'd, Furnish F F Class III Drive Req'd. W = 25.4' + 6 4 .4 C1 90°0'0" Constr. Limits Constr. Limits R R 6 '-0 " 2 1 '-0 " 2 1 '-0 "A A A A Mod. Class III Drive Req'd. Mod. Class III Drive Req'd. Mod. Class III Drive Req'd. W = 35.6' Temp. R/W Temp. R/W Temp. R/WTemp. R/W P.I. 108+56.97 "PR-RL1" 33.0' RT. +45.9, Match Exist. 5'x4' Temp. R/W 7'R 15' R 1 0 ' R 30 'R 20 'R 10'R 3 0' R 30 'R 20 'R 10'R Match Exist. 5'x4' 6 '- 0 " 8 '-0 " 37.00' RT. +97.67 6 ' - 0 " F1 C1 5'R 5' R 8 '-0 " 3 '-0 " F F See Line "PR-S1A" Str. No. 348A 152 '-0" 4 4 4 4 4 4 4 4 52.2'R 18 'R 49.68' LT. +62.16 18 " rcp 78.17' LT. +30.52 1 0 '- 0 " 35.00' LT. +35.00 36.7' LT. +27.0 grassMatch Exist. 47.23' LT. +72.69 ov erhang 2.00' LT. 108+00.11 "PR-RL1" Corner Req'd Monument, Section R/W S-MART REAL ESTATE, INC. Temp. R/W LD LD LD LD EM EM E GM W W W W W W T H H H H H H H H CC -TR W V WV CC-TR T H W V C W V H H B PZZ Z PZZZ H H T G P F LEGEND Full Depth HMA Pavement (See Typical Sections) F1 K X T PCCP Truck Apron (See Typical Sections) C C1 F Sidewalk, Concrete, 4 In. (See Carmel Std. Dwg. 10-18) K1 HMA for Approaches (Full Depth Pavement) R 28A Mill 1.5 in. & Resurface R1 HMA Wedge & Level (See Typical Sections) 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D Roll Curb for Truck Apron (See City of Carmel Std. 10-25C) Widening with PCC Base, 6" (See Typical Sections) HMA For Structure Installation, Type C (Full Depth Pavement) Widening with HMA, Typc C (Full Depth Pavement) Raised Pedestrian Crossing (See Miscellaneous Details) PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on Subgrade Treatment Type II 14 Straight Concrete Curb, Modified Curb Ramp, Concrete (See Curb Ramp Details) Shared-Use Path (See Typical Sections) 17 Curb & Gutter, Concrete, Type III 4 Planting Areas (See Landscape Plans) RJCTJM NRM NRM CONSTRUCTION DETAILS LINE "PR-RL1" N/A 1"=20' BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 32 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CD.PR-RL1.02.dgn5/24/2021 09:43:33 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Line "PR-RL1" HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E KRG CENTRE LLC AUTOZONE INC (Autozone) Ap p . P .L. App. Exist. R/W conc. grass grass 36" rcp 12" vcp grass grass App. Exist. R/W brick App. Section LineRange Line Rd. asphalt con c. conc. asph alt 1 1 5 asphalt grass riprap asphalt conc. KRG CENTRE LLC App. Exist. R/W 12" cpp 12" rcp (12 " brick wall ) (2-sty brick)grass 8" cpp 12" rcp 12" rcp 12" rcp asphalt conc. 36" rcp 12" rcp 36" rcp grass (brick CVS) conc. con c. II COMPANY BARNES INVESTMENTS asphalt conc. 12" rcp grass conc. a s ph alt 8" c pp 24 " cpp asphalt 12 " rcp App. Exist. R/W 12 " rcp a s ph alt conc.grass conc. asphalt 12 " rcp gras s asphalt con c. Ap p . P.L. Ap p . P .L.D & W HOLDINGS LLC asphalt con c. gra ss conc. conc. grass App. Exist. R/W 36" rcp App. Exist. R/W conc. grass conc. grass grass Ap p . P.L. O P E R A T I O N S L L C B F S R E T A IL & C O M M E R C I A L 12 " rcp grass asph alt 36" rcp LIVING TRUST REVOCABLE PATRICIA R. EMMERT asph alt grass conc. grass asphalt brick M e d ica l D r . a s ph alt 6" steel 12 " vcp 30" rcp conc. gra s s Con c. gra s s conc. grass grass plante r asphalt asphalt 2 1 '-0 "6 '-0 " 2 1 '-0 " + 6 1 . 1 Class III Drive Req'd. W = 56.6' + 2 2 . 6 90°0'0" 90°0'0" Class III Drive Req'd. W = 37.2' + 8 1 . 6 Class III Drive Req'd. W = 26.5' + 0 2 .0 6 '-0 " 8 '-0 " + 70 .9, 18 .6' RT. Constr. Limits Constr. Limits 8 '-0 " 6 '-0 " 8 '-0 " 6 '-0 " grass To Remain As Is +6 0.1, 3 2.6' R T. Temp. R/W Temp. R/W 90°0'0" asphalt Lin e "PR -S 2 A" conc. planter grass conc. Con c. N 9 0 ° 0 0 '0 0 " E Lin e "P R-S 2 A" overhang overhang overhang 14+06.00 "PR-S2A" END CONSTRUCTION P.T. 13+48.99 "PR-S2A" P.I. 13+28.94 "PR-S2A" P.C. 13+08.79 "PR-S2A" 10+90.00 "PR-S2A" BEGIN CONSTRUCTION P.T. 11+80.91 "PR-S2A" P.C. 11+20.72 "PR-S2A" 31'-0"31'-0" 3 1 ' - 0 " 31'-0" conc. asph alt L = 60.19' CURVE DATA T = 30.24' P.I. = 11+50.96 "PR-S2A" R = 250.00' E = 1.82' S.E. = N.C. CURVE DATA T = 20.14' L = 40.20' P.I. = 13+28.94 "PR-S2A" R = 250.00' E = 0.81' S.E. = N.C. 81°49'06" T Temp. R/W No Curve Run �=22°49'37" LT. P.I. 12+25.69 "PR-S2A" = Adjust Casting to Grade Str. No. 401B Str. No. 504 +01 .0 R T. Str. No. 505 6' of 12" Pipe Req'd Inlet, Type "M-10" & 2' of 12" Pipe Req'd Inlet, Type "J-10" & 4' of 36" Pipe Req'd Manhole, Type "J-4" & Str. No. 503 Str. No. 501 +93.0 LT.45' of 12" Pipe Req'd Inlet, Type "M-10" & Str. No. 502 +9 9.0 L T.3' of 12" Pipe Req'd Inlet, Type "M-10" & Str. No. 521 Str. No. 507 +18 .5 , 48 .2' LT . Req'd, Furnish and Adjust to Grade Reconstruct Manhole 2 LFT and Flat Casting 41' of 12" Pipe Req'd Inlet, Type "J-10" & Str. No. 508 3' of 12" Pipe Req'd Inlet, Type "J-10" & 5' of 12" Pipe Req'd Inlet, Type "M-10" & Str. No. 511 + 53 .0 RT.+ 60 .0 RT. 3' of 12" Pipe Req'd Inlet, Type "J-10" & Str. No. 509 + 55 .0 LT . Str. No. 512 37' of 12" Pipe Req'd Inlet, Type "M-10" & 4' of 36" Pipe Req'd Manhole, Type "J-4" & Str. No. 510 +6 0.0, 1 6.4' R T. Str. No. 513 Str. No. 514 + 0 4 . 9 , 3 1 . 4 ; R T . Adjust Casting to Grade Str. No. 515 + 7 1 . 7, 6 0 . 9' R T. To Remain As Is Adjust Casting to Grade Str. No. 318 + 71 .0 RT. Str. No. 318A 4' of 12" Pipe Req'd Inlet, Type "R-13" & Str. No. 516 39' of 12" Pipe Req'd Inlet, Type "J-10" & + 62 .0 LT . + 0 0 . 0 L T . 4' of 36" Pipe Req'd Manhole, Type "J-4" & Str. No. 517 Str. No. 519 +36.0 " PR- S2 A" RT. 17' of 12" Pipe Req'd Inlet, Type "J-10" & Str. No. 518 25' of 12" Pipe Req'd Inlet, Type "M-10" & +35.0 "PR-S2A" LT. Str. No. 520 89' of 12" Pipe Req'd Inlet, Type "M-10" & +62.0 "PR-S2A" LT. Constr. Limits Constr. Limits 14'-0"14'-1" F F 8'-0" 8'- 0" 8 '-0 " 3 '-0 " 3'- 0" 6'-0" 8'-0" F1 F1 F1 8 '-0 " 6 '- 0 " 14'-0"15'-0" 24.00' RT. +25.00 3.00' RT. +25.00 24.00' LT. +25.00 3.00' LT. +25.00 5'-0" Mod. Class III Drive Req'd. W = 25.2' Temp. R/W Temp. R/W Temp. R/W Temp. R/W Temp. R/W Temp. R/W R/W R / W R/W R/W 3'-0" Retaining Wall No. 1 P.O.T. 12+32.76 "PR-S2A" P.O.T. 114+61.91 "PR-RL1"= P.I. 11+50.96 "PR-S2A" Temp. R/W + 07 .0 RT.15.5' RT.+01.0,Temp. R/W Constr. Limits 36" rcp16.6' RT.+96.1, 18 .0 ' R T . + 0 0 .0 , Temp. R/W Tem p. R/ W T e m p . R/ W R/W Temp. R/W Ap p . E x is t . R/ W R/W 24.00' LT. +65.00 24.00' RT. +65.00 3.00' LT. +65.00 3.00' RT. +65.00 15.93' RT. +42.79 "PR-S2A" 14.93' RT. +75.00 "PR-S2A" 14.55' RT. +20.72 "PR-S2A" 14.00' LT. +75.00 "PR-S2A" 14.42' LT. +20.72 "PR-S2A" grass 20 'R 10' R 20'R 1 0' R 20'R 3 0' R 15'R Constr. Limits Co n s tr . Lim it s 26.7' LT. +21.5 "PR-S2A" Match Exist. Match Exist. 5'x6' 3.93' RT. +43.10 "PR-S2A"2.07' LT. +43.24 "PR-S2A" + 1 7 . 1, 1 6 . 2' R T. Str. No. 506 Adjust Casting to Grade 14'-0" +90.0 "PR-S2A" LT. 2.44' RT. +25.45 "PR-S2A" R/W Constr. Limits 2.57' LT. +25.36 "PR-S2A" C o n s tr. Lim it s 90°0'0" Te m p . R / W Temp. R/W F1 F1 8' R 5'R 5'R 3 0'R R 15 13 13 R 15 A A A A C1 C1 C1 C1 F1 15 F1 R R 15 13 13 16 13 R A A 2828 2828 28 28 28 28 F1 F1 15 15 15 17 1515 15 15 1313 13 13 13 13 13 16 R1 R1 A A 15 R K K A A A 14 K R R A A A A R1 14 14 F 22 22 X13 X14 X15 X16 X17 X18 X19 X20 X21 X22 X23 X24 13 13 F 14 F 17 44 T 4 4 4 4 4 15'-3" 14'-4" 17'R31.91' LT. +90.31 "PR-S2A" 9 '-1 " 35.89' RT. +18.57 35.56' RT. +71.44 35.18' RT. +15.00 35.03' RT. +75.00 32.00' RT. +97.13 1 0 '- 0 " 8 '-0 " 8 '-0 " 1 0 '- 8 " 9 '-5 " 8 '-0 " 32.00' LT. +77.42 28.94' LT. +23.00 3'-0" 3 '-0 " 37'-2" 1 0 0 '-0 "19'-0" 12'-0" 5'-0" 13 A Existing Light Pole Do Not Disturb 3'R 4 ' R 2' R2'R 47.54' LT. +87.96 49.75' RT. +00.00 "PR-S2A" 28.50' RT. +18.60 "PR-S2A" 27.75' RT. +24.00 "PR-S2A" 44.95' RT. +24.60 "PR-S2A" 34.33' RT. +46.35 "PR-S2A" 13 3'R3'R 18'-6" 25.57' RT. 14+62.49 "PR-S2A" 60.20' RT. 14+60.91 "PR-S2A" 35.34' RT. 14+77.36 "PR-S2A" A App. P.L. Parking Addition Detail M e d ic a l D r . Private Light, Relocate Private Light, Relocate LD LD H H H H T H H CC -T R C W M W V WV W V W V W V PZZ Z PZZ Z PZZ Z PZZ Z H H H T WV LD H C WV G H B PZZZ PZZZ F P 836.0848344BRK LEGEND Full Depth HMA Pavement (See Typical Sections) F1 K X T PCCP Truck Apron (See Typical Sections) C C1 F Sidewalk, Concrete, 4 In. (See Carmel Std. Dwg. 10-18) K1 HMA for Approaches (Full Depth Pavement) R 28A Mill 1.5 in. & Resurface R1 HMA Wedge & Level (See Typical Sections) 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D Roll Curb for Truck Apron (See City of Carmel Std. 10-25C) Widening with PCC Base, 6" (See Typical Sections) HMA For Structure Installation, Type C (Full Depth Pavement) Widening with HMA, Typc C (Full Depth Pavement) Raised Pedestrian Crossing (See Miscellaneous Details) PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on Subgrade Treatment Type II 14 Straight Concrete Curb, Modified Curb Ramp, Concrete (See Curb Ramp Details) Shared-Use Path (See Typical Sections) 17 Curb & Gutter, Concrete, Type III 4 Planting Areas (See Landscape Plans) MO N W V (wood gate) 10" vcp 6" pvc 12 " cpp con c. gra ss grass asph alt 30" rcp TJM NRM RJC NRM CONSTRUCTION DETAILS LINE "PR-RL1" N/A 1"=20' BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 33 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CD.PR-RL1.03.dgn5/24/2021 09:43:34 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Ap p . P .L. OPERATIONS LLC BFS RETAIL & COMMERCIAL 1 2 0 Ap p . P .L. ENTERPRISES J & J REALTY Ap p . P .L. HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E FINEBERG GROUP LLC HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E FINEBERG GROUP LLCAp p . P.L. REVOCABLE LIVING TRUST PATRICIA R. EMMERT App. Exist. R/W App. Exist. R/W 12 " rcp App. Section Line gra ss asphalt 18 " cpp con c. conc. grass 12 " rcp 36" rcp App. Exist. R/W grass conc. conc. grass App. Exist. R/W 12" rcp asphalt 4" cpp 12" rcp asphalt 36" rcp asphalt asphalt 12" rcp conc. grass 36" rcp grass 12 " rcp asphalt 12" rcp 4" cpp grass conc. 12 " rcp grass conc. 12 " rcp 12" rcp 42 " rcp 1 2" rc p brick conc. App. Exist. R/W con c. 36" rcp conc. brick conc. grass grass asphalt App. Exist. R/W App. Exist. R/W STORES LLC MACS CONVENIENCE Ap p . P.L. conc. conc. as ph alt (2-sty brick) conc. 1 2 " r c p grass conc. grass asphalt conc. grass stone a sph alt asphalt a s ph alt con c. conc. grass grass grass asphalt ston e 12 " rcp 12 " rcp conc. 36" rcp KRG CENTRE LLC Line "PR-RL1" 6 '-0 " 2 1 '-0 " R 15 2 1 '-0 " R 15 13 13 conc. asphalt asph alt conc. conc. asphalt asphalt asphalt A A A A W = 26.5' + 4 4 .6 90°0'0"90°0'0" 90°0'0"90°0'0" Adjust Casting to Grade Str. No. 320 + 3 6 . 0 R T. + 0 2 .0 + 9 7 .7 W = 21.1'W = 34.5' + 6 1 .1 + 0 3 .5 Adjust Casting to Grade Str. No. 319 + 3 5.2 L T. 6 '-0 " 8 '-0 " 6 '-0 " 8 '- 0 " F1 F1 Str. No. 323+50.0, 45.5' LT. + 7 0 . 9, 1 8 . 6' R T. + 3 8 . 6 , 3 3 . 4' L T . + 26 .6 , 31 .2 ' LT . + 57 .9 , 40 .4 ' LT. Str. No. 324 Constr. Limits Constr. Limits Constr. Limits Constr. Limits 8 '-0 " F1 8 '-0 " 6 '-0 " 24' of 12" Pipe Req'd Inlet, Type "E-7" & F 90°0'0" grass C1 C1 asphalt 90°0'0"90°0'0" 90°0'0" 90°0'0" + 4 8 . 3 conc. + 2 1 . 7 + 4 3 . 7 Class III Drive Req'd. W = 31.3' + 1 9 .1 W = 24.9' + 9 0 . 5 15 15 A A A A A 22 Range Line Rd. asphalt Range Line Rd. asphalt 15 F1 Adjust Casting to Grade Str. No. 326 + 7 3 . 7 R T . Adjust Casting to Grade Str. No. 325 + 58 .3 LT . Adjust Casting to Grade Str. No. 327 + 22.1 LT . See Previous Sheet Str. No. 318 & Adjust Casting to Grade Flat Casting Req'd, Furnish Str. No. 321 & Adjust Casting to Grade Flat Casting Req'd, Furnish Str. No. 322 & Adjust Casting to Grade Flat Casting Req'd, Furnish + 3 2 . 0 R T . Adjust Casting to Grade Str. No. 328 15 App. Exist. R/W Temp. R/W Temp. R/W 24.00' RT. +19.05 122+12.93 "PR-RL1" INCIDENTAL CONSTRUCTION END PROJECT & BEGIN 25.74' RT. +53.54 14.92' RT. +31.82 21.31' RT. +91.50 All Radii are Measured from Curb Face Unless Otherwise Noted. All R/W Described from Line "PR-RL1", Except as Shown. NOTE: 3.00' RT. +12.93 0.63' LT. +81.12 0.63' LT. +38.09 5.70' LT. +99.96 8.47' LT. +99.56 4.63' LT. +47.91 4.63' LT. +81.12 3.00' LT. +12.93 24.00' LT. +90.00 27.79' LT. +60.24 29.81' LT. +54.73 47.64' LT. +50.17 See Previous Sheet Str. No. 318A + 7 1 . 0 R T . Mod. Class III Drive Req'd. W = 23.3' Mod. Class III Drive Req'd. W = 25.9' Mod. Class III Drive Req'd. W = 28.2' Mod. Class III Drive Req'd. Mod. Class III Drive Req'd. W = 33.8' Mod. Class III Drive Req'd. W = 24.7' Mod. Class III Drive Req'd.Mod. Class III Drive Req'd. Mod. Class III Drive Req'd. Temp. R/W 20'R F Match Exist. 5'x5' 15'R 2 0' R 20 'R 2 0' R 20 'R 2 0' R 20'R 20' R 10 'R 1 5' R 20 'R 15'R 1 0' R 1 7' R17 'R 2 0' R15'R15'R15 'R 1 5' R F Match Exist. 5'x10' 90°0'0" 3 0 0 ' R 3 5 0 ' R 5 0 0 ' R 3 8 0 ' R F1F1 C1 30 'R C1 C1 C1 C1 C1 C1 C1 C1 F1F1 F1 1 2 5 4 4 4 8 '- 0 " 8 '- 0 " 6 '-0 " 6 '-0 " 32.00' RT. +53.44 34'-5" 3 ' - 0 " 1 5 0' R 36.32' LT. +09.72 38.62' LT. +20.45 124+63.91 "PR-RL1" END INCIDENTAL CONSTRUCTION Constr. Limits Constr. Limits Constr. Limits Constr. Limits Constr. Limits Constr. Limits H C WV T C WM G T H H FP H H H TR LEGEND Full Depth HMA Pavement (See Typical Sections) F1 K X T PCCP Truck Apron (See Typical Sections) C C1 F Sidewalk, Concrete, 4 In. (See Carmel Std. Dwg. 10-18) K1 HMA for Approaches (Full Depth Pavement) R 28A Mill 1.5 in. & Resurface R1 HMA Wedge & Level (See Typical Sections) 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D Roll Curb for Truck Apron (See City of Carmel Std. 10-25C) Widening with PCC Base, 6" (See Typical Sections) HMA For Structure Installation, Type C (Full Depth Pavement) Widening with HMA, Typc C (Full Depth Pavement) Raised Pedestrian Crossing (See Miscellaneous Details) PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on Subgrade Treatment Type II 14 Straight Concrete Curb, Modified Curb Ramp, Concrete (See Curb Ramp Details) Shared-Use Path (See Typical Sections) 17 Curb & Gutter, Concrete, Type III 4 Planting Areas (See Landscape Plans) TJM NRM RJC NRM CONSTRUCTION DETAILS LINE "PR-RL1" 1"=20' N/A BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 34 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CD.PR-RL1.04.dgn5/24/2021 09:43:36 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 18" cpp 116th St. asphalt asphalt grass 15 " rcp grass App. Exist. R/W grass asphalt 12" rcp grass conc. asphalt grass App. Exist. R/W App. Exist. R/W grass 12 " rcp 8" vcp 8" vcp 6" pvc3" pvc 8" pv c 4" pv c Ea seme nt No Acc e ss 1 5 .0' asphalt 8" pvc ASSOCIATION INC HOMEOWNERS FAIRGREEN TRACE Ap p . P.L.ANITA L. NIX ROGER E. & Ap p . P. L. KRG CENTRE LLC 12" rcp grass 1 2 " c p p 12 " rcp asphalt 12" cpp 12 " cpp App. Exist. R/W con c. grass con c. Ap p . S e c ti o n Lin e asphalt asphalt grass grass con c. conc. Ap p . E x is t . R/ W a s ph alt grass 42 " rcp 42 " rcp SPEEDWAY LLC App. Exist. R/W grass conc. con c. 8" vc p 6" vcp 21" rcp Line "PR-S1A" Lin e "PR-RL1" App. Section Line 15 " cp p a sphalt conc. CARMEL CLAY PARKS BUILDING CORPORATION Ap p. P.L. asphalt (1-sty brick/frame) conc. asphalt CORNER ASSOCIATES LP asph alt grass conc. grass conc. stone 1 2 " rcp 12 " rcp 12" rcp 12" rcp grass conc. grass Ap p . E x is t . R/ W asphalt gras s con c. gra s s con c. Ap p . Exis t. R / W 42 " rcp gra ss con c. con c. asphalt (1-sty brick) conc. conc.grassApp. Exist. R/W 4 2 " rcp asphalt HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 1, T 17 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 6, T 17 N, R 4 E grass asphalt con c. con c. CURVE DATA P.I. = 108+56.97 "PR-RL1" T = 66.69' L = 131.64' R = 333.00' E = 6.61' S.E. = N.C. CURVE DATA P.I. = 106+87.87 "PR-RL1" T = 26.35' R = 333.00' E = 1.04' S.E. = N.C. L = 52.60' Line "PR-S1A" asphalt 12 " rcp 18" rcp asph a lt asph alt P.R.C. 106+61.52 "PR-RL1" P.I. 106+87.87 "PR-RL1" P.I. 108+56.97 "PR-RL1" 3 5 T 16 13 15 15 F R 2 5 .0 ' Ease m ent S.D. & U. Ra n g e Lin e R d . W e s tfie ld B lv d . 32+80.00 "PR-S1A" BEGIN CONSTRUCTION A 22 + 8 3 . 3 C1 A Str. No. 345 + 74 .0 RT. Str. No. 306 See Line "PR-RL1" Str. No. 305 See Line "PR-RL1" Str. No. 344 + 7 3 . 0' L T . Str. No. 310 See Line "PR-RL1" Str. No. 309 See Line "PR-RL1" Str. No. 312 See Line "PR-RL1" K K F1 29'-0" 29.44' LT. +15.00 +15.00 6.73' RT. + 80 .0 RT. Str. No. 346 26' of 15" Pipe Req'd Inlet, Type "M-10" & Str. No. 347 + 8 0 . 0 LT . Str. No. 400 See Line "PR-RL1" Str. No. 308 See Line "PR-RL1" Str. No. 307 See Line "PR-RL1" Constr. Limits Constr. Limits F 5'- 0" & R/ W Ap p . P . L. R/W R/W R/W F F CURVE DATA P.I. = 33+63.03 "PR-S1A" T = 31.97' L = 63.85' R = 470.00' E = 1.09 S.E. = N.C. CURVE DATA P.I. = 34+98.11 "PR-S1A" T = 103.21' L = 205.61 R = 950.00' E = 5.56' S.E. = N.C. A P.I. 34+98.11 "PR-S1A" P.C. 33+31.06 "PR-S1A" P.I. 33+63.03 "PR-S1A" P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = O.P.O.C. 36+08.35 "PR-S1A", 7.94' RT. O.P.O.T. 107+80.65 "PR-RL1", 5.81. RT.= 37'-0"10'-0" � ROUNDABOUT 2 9 '-0 " R 28.74' RT. +15.00 Class III Drive Req'd. W = 26.5' 30.0' LT. +80.0 31.9' RT. +80.0 C1 15 13 15 13 8 ' - 0 " 6 '- 0 " 83°37'45" 27.23' LT. +51.56 P.R.C. 33+94.91 "PR-S1A" X7 F 15 8'- 0 " 6'- 0 " F 2 9 '- 0 " X8 X9 13 6'-0" 5'-0" R / W App. Exist. R/W R/W 14 A 6'-0" X2 X1 X3 X6 6'-0" 8'-0" 12" rcp F1 X5 X4 P.R.C. 109+21.92 "PR-RL1" 15 K K 13 13 (Match Exist.) (Match Exist.) P .T . 1 0 7 + 1 4 .1 2 " P R- RL1 " 8.00' LT. +44.00 7.37' LT. +15.00 F 30.00' LT. +31.06 3' of 15" Pipe Req'd Inlet, Type "M-10" & Str. No. 348 + 1 1 . 0 L T. 29.50' RT. +15.00 38.00' LT. +99.94 41.67' RT. +96.87 36.65' RT. +35.51 & 7' of 18" Pipe Req'd Manhole, Type "J-10" Str. No. 342 + 20.0' RT. 52' of 12" Pipe Req'd Inlet, Type "J-10" & Mod. Class III Drive Req'd. W = 27.5' Temp. R/W Temp. R/W S-MART REAL ESTATE, INC. Ap p . Exis t. R / W T e m p . R/ W T e m p . R/ W T e m p . R / W 8.53' RT. +44.00 3 0' R 30'R F Match Exist. 6'x10' F Connect to Exist. Trunkline 6' of 12" Pipe Req'd & Str. No. 341 + 1 4 . 9 L T . 46' of 12" Pipe Req'd Manhole "J-10" & Str. No. 343 + 21 .0 LT . 10 'R 74.36' LT. +62.71 51.39' LT. +29.95 52.2'R 18'R 3' of 12" Pipe Req'd Inlet, Type "M-10" & 46' of 12" Pipe Req'd Inlet, Type "M-10" & 33' of 12" Pipe Req'd Manhole, Type "C-4" & Str. No. 348A +17.5, 0.0' R T. 4 4 4 4 4 4 4 R/W Temp. R/W 2 8 '- 1 " 28 '-7" 4.64' LT. +52.54 5.48' RT. +52.40 5 '-0 " + 1 1 .2 20' R Match Exist. "PR-S1A") (Tan. to 89°3'57" 15'R 7.50' RT. +51.10 4.00' RT. +51.05 Future Drive Entrance K LD LD GM W W W W W W T H H H H H H CC-TR C WV WV WV WV CC-TR T H WV C WV H T H T T EM H T G PF LEGEND Full Depth HMA Pavement (See Typical Sections) F1 K X T PCCP Truck Apron (See Typical Sections) C C1 F Sidewalk, Concrete, 4 In. (See Carmel Std. Dwg. 10-18) K1 HMA for Approaches (Full Depth Pavement) R 28A Mill 1.5 in. & Resurface R1 HMA Wedge & Level (See Typical Sections) 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D Roll Curb for Truck Apron (See City of Carmel Std. 10-25C) Widening with PCC Base, 6" (See Typical Sections) HMA For Structure Installation, Type C (Full Depth Pavement) Widening with HMA, Typc C (Full Depth Pavement) Raised Pedestrian Crossing (See Miscellaneous Details) PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on Subgrade Treatment Type II 14 Straight Concrete Curb, Modified Curb Ramp, Concrete (See Curb Ramp Details) Shared-Use Path (See Typical Sections) 17 Curb & Gutter, Concrete, Type III 4 Planting Areas (See Landscape Plans) CONSTRUCTION DETAILS LINE "PR-S1A" 1"=20' N/A RJC NRM TJM NRM BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 35 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CD.PR-S1A.01.dgn5/24/2021 09:43:37 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 HAMILTON COUNTY CLAY TOWNSHIP SEC. 6, T 17 N, R 4 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 31, T 18 N, R 4 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 36, T 18 N, R 3 E HAMILTON COUNTY CLAY TOWNSHIP SEC. 1, T 17 N, R 3 E gras s con c. gras s con c. Lin e "PR-RL1" P.T. 107+14.12 "PR-RL1" P.I. 106+87.87 "PR-RL1" 18" rcp 8 " vcp 6" vcp 21" rcp 4 2" rcp 42 " rcp 42 " rcp 12" rcp KRG CENTRE LLC App. Exist. R/W grass conc. Ap p . S e c t i o n Lin e con c. a sph a lt con c. gra ss P.I. 108+56.97 "PR-RL1" CORNER ASSOCIATES LP grass con c. 4 0 8" pvc (gas pumps) conc.asphalt SPEEDWAY LLC 30 " rcp 8" pvc 8" pv casphalt 30.0' Easement Utility asphalt Ap p . P . L. 20.0' Easement Utility asphalt 42" rcp App. Exist. R/W12" rcp riprap WOODLAND SHOPPES App. Exist. R/W asphalt grass grass riprap grass conc. asphalt App. Exist. R/W conc. conc. 1 2 " cpp 12" rcp 12 " rc p grass conc. asphalt conc.grass a s p h a lt App. Exist. R/W App. Exist. R/W conc. grass 12" rcp conc. conc.6" pvc 3" pvc 2" pv c grass asphalt (gas pumps) (1-sty block gas station) asphalt (block ca r wash) con c. conc. PROPERTY GROUP LLC MILLER McCOMAS Ap p . P .L. KAREN C BROWN CHARLES M & conc. grass 12" rcp conc.12" rcp grass conc. 48 " rcp conc. conc. grass App. Section Line asphalt 116th St. Line "PR-S1A" CURVE DATA P.I. = 108+56.97 "PR-RL1" T = 66.69' L = 131.64' R = 333.00' E = 6.61' S.E. = N.C. CURVE DATA P.I. = 106+87.87 "PR-RL1" T = 26.35' R = 333.00' E = 1.04' S.E. = N.C. L = 52.60' 15 15 13 13 con c. 42 " rcp Ra n g e Lin e R d . A � ROUNDABOUT + 9 5 . 4 + 1 0 . 7 Str. No. 352 conc. Mod. Class III Drive Req'd. W = 50.1' 90°0'0" K C1 C1 Str. No. 310 See Line "PR-RL1" Str. No. 312 See Line "PR-RL1" See Line "PR-RL1" Str. No. 308 Str. No. 306 See Line "PR-RL1"Str. No. 305 See Line "PR-RL1" Str. No. 349 + 0 3 . 0 R T.70' of 15" Pipe Req'd Inlet, Type "M-10" & Str. No. 355 + 0 7 . 0 R T. Str. No. 357 + 1 3. 0 R T. 2' of 12" Pipe Req'd Inlet, Type "J-10" & Str. No. 353 44' of 12" Pipe Req'd Inlet, Type "R-13" & + 04 .0 , 6 5 .5' LT . Str. No. 356 3' of 12" Pipe Req'd Inlet, Type "R-13" & + 13 .0 LT . 32' of 12" Pipe Req'd Inlet, Type "R-13" & Str. No. 354 2 9 '- 0 " 2 9 '-0 " 29'-0" A F1 Ap p . Exis t. R / W F con c. F R 22 A Str. No. 400 See Line "PR-RL1" Str. No. 309 See Line "PR-RL1" 13 Str. No. 307 See Line "PR-RL1" 1 3 . 5' R T. + 0 7 . 7, + 7 3 . 2 , 3 3 . 6 ' LT . Constr. Limits Constr. Limits P.R.C. 109+21.92 "PR-RL1" 8'-0" 6'-0" Ap p . E x is t . R/ W Ap p . P . L. & R / W R/W CURVE DATA P.I. = 36+75.13 "PR-S1A" T = 74.62' L = 145.03' R = 250.00' E = 10.90' S.E. = N.C. CURVE DATA P.I. = 38+08.54 "PR-S1A" T = 63.00' L = 125.34' R = 500.00' E = 3.95' S.E. = N.C. Mod. Class III Drive Req'd. W = 44.6' 39+55.00 "PR-S1A" END CONSTRUCTION 30.0' RT. +88.0 5.00' LT. +80.28 30.8' LT. +55.0 30.00' LT. +80.28 (Match Exist.) 27.2' RT. +55.0 (Match Exist.) (Match Exist.) 4.89' RT. +60.00 30.09' RT. +60.00 A 29.71' LT. +60.00 4.70' LT. +60.00 K 8 ' - 0 " P.T. 38+70.88 "PR-S1A" P.I. 38+08.54 "PR-S1A" P.R.C. 37+45.54 "PR-S1A" App. Exist. R/W asphalt asphalt Line "PR -S1A" 6'- 0 " 5'- 0 " F1 8'-0" 6'-0" F1 13 R/ W X1 Ap p . E x is t . R/ W W e s tfie ld B lv d . P.R.C. 106+61.52 "PR-RL1" a sph a lt a sph a lt X2 X3 Ap p . Exis t. R / W15 F 6'-0" 5'-0" K 5'- 0" 6'-0" F 13 16 T10'-0"37'-0" K15 8'-0" 6'-0" X4 X5 X6 F 13F1 O.P.O.C. 36+08.35 "PR-S1A", 7.94' RT. O.P.O.T. 107+80.65 "PR-RL1", 5.81. RT. = 13 15 X11 X10 X12 15 15 82°50'08" 1 2 " rc p (Tan. to "PR-S1A") App. Exist. R/ W A 14 29 '-5" P.T. 36+00.51 "PR-S1A" P.C. 107+90.28 "PR-RL1"= 2 7'- 1 0 " Str. No. 402 Reconstruct Manhole 2 LFT Str. No. 350+ 0 6. 0 L T . 3' of 12" Pipe Req'd Inlet, Type "J-10" & Str. No. 351 App. P.L. & R/W conc. 4' of 21" Pipe Req'd with Flat Casting & Manhole, Type "C-4" + 09 .0, 45 .5' LT . & 2' of 21" Pipe Req'd Manhole, Type "K-4" + 07 .0 LT . + 47.0 LT . Str. No. 358 33' of 12" Pipe Req'd Inlet, Type "J-10" & P.I. 36+75.13 "PR-S1A" 36.09' RT. +75.75 38.72' RT. +30.50 Temp. R/W T e m p . R / W 63' of 12" Pipe Req'd Manhole, Type "C-10" & COYOTE ENTERPRISES, LLC. Temp. R/W T e m p . R / W 20'R 30'R 10' R 20'R 2 0 0 ' R 5.00' RT. +80.28 4 4 4 4 4 4 4 37.24' LT. +35.56 40.55' LT. +85.21 R/W R/W Ap p . P . L.Ap p . P . L. S-MART REAL ESTATE, INC. R/W Temp. Temp. R/W + 5 2 . 4 W = 30.5' Class III Drive Req'd. C1 90°00'00" "PR-S1A") (Tan. to F 5 ' - 0 " 15'R 15'R LD LDLD LD EM EME W W W W W W W W W W W W W T T H H H H H H H H CC-TR WV WV CC-TR T H WV C WV G PZZZ H H H T PF LEGEND Full Depth HMA Pavement (See Typical Sections) F1 K X T PCCP Truck Apron (See Typical Sections) C C1 F Sidewalk, Concrete, 4 In. (See Carmel Std. Dwg. 10-18) K1 HMA for Approaches (Full Depth Pavement) R 28A Mill 1.5 in. & Resurface R1 HMA Wedge & Level (See Typical Sections) 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D Roll Curb for Truck Apron (See City of Carmel Std. 10-25C) Widening with PCC Base, 6" (See Typical Sections) HMA For Structure Installation, Type C (Full Depth Pavement) Widening with HMA, Typc C (Full Depth Pavement) Raised Pedestrian Crossing (See Miscellaneous Details) PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on Subgrade Treatment Type II 14 Straight Concrete Curb, Modified Curb Ramp, Concrete (See Curb Ramp Details) Shared-Use Path (See Typical Sections) 17 Curb & Gutter, Concrete, Type III 4 Planting Areas (See Landscape Plans) TJM NRM RJC NRM CONSTRUCTION DETAILS LINE "PR-S1A" 1"=20' N/A BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 36 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CD.PR-S1A.02.dgn5/24/2021 09:43:38 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 40+00 116th St. Line "NECL-116" P.I. 40+64.08 "NECL-116" P.I. 41+62.45 "NECL-116" Line "SECL-116" R a n g e Lin e R d . P.I. 42+25.03 "NECL-116" P.I. 43+01.60 "NECL-116" P.I. 12+86.56 "NWCL-116" 10+00 20+00 Line "SWCL-116" Line "NWCL-116" 116th St. 3 0 + 0 0 Lin e "N ECL- 1 1 6 " Lin e "NW CL-1 1 6 " Lin e "S W CL-1 1 6 " Lin e " S E CL-1 1 6 " O.P.O.T. 105+77.11 "PR-RL1", 30.00' RT. P.O.T. 30+00.00 "SECL-116" = O.P.O.T. 105+75.00 "PR-RL1", 30.00' LT. P.O.T. 24+25.97 "SWCL-116" = ROUNDABOUT ALIGNMENT SUMMARY TABLE O.P.O.T. 110+11.79 "PR-RL1", 30.00' LT. P.T. 14+00.43 "NWCL-116" = ROUNDABOUT ALIGNMENT SUMMARY TABLE O.P.O.T. 38+80.28 "PR-S1A", 30.00' LT. P.C. 40+00.00 "NECL-116" = O.P.O.T. 38+87.99 "PR-S1A", 30.00' RT. P.O.T. 33+84.11 "SECL-116" = O.P.O.C. 109+66.20 "PR-RL1", 29.01' RT. P.T. 43+57.08 "NECL-116" = P.I. 12+21.49 "NWCL-116" P.I. 10+42.28 "NWCL-116" P.I. 11+44.34 "NWCL-116" P.I. 13+59.40 "NWCL-116" O.P.C. 33+31.06 "PR-S1A", 30.00' LT. P.C. 10+00.00 "NWCL-116" = P.I. 20+54.45 "SWCL-116" P.I. 22+12.67 "SWCL-116" P.I. 22+76.56 "SWCL-116" O.P.O.T. 32+80.00 "PR-S1A", 31.87' RT. P.O.T. 20+00.00 "SWCL-116" = P.I. 23+43.88 "SWCL-116" W e s t fie ld Blv d . P.I. 31+54.91 "SECL-116" P.I. 30+89.73 "SECL-116" P.I. 30+54.42 "SECL-116" P.I. 32+71.93 "SECL-116" RJCNRM MJM MJM ROUNDABOUT ALIGNMENT PLAN N/A 1"=30' 116TH ST. REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "NECL-116"40+64.08 715,249.9266 9,324.0265 13° 55' 02.72" LT 64.08'127.52'525.00'3.90'P.C. 40+00.00 P.R.C. 41+27.53 S 89° 51' 20.93" W S 75° 56' 18.21" W 41+62.45 715,225.8719 9,227.9884 42° 25' 12.56" RT 34.93'66.63'90.00'6.54'P.R.C. 41+27.53 P.T. 41+94.16 S 75° 56' 18.21" W N 61° 38' 29.23" W 42+25.03 715,257.1276 9,170.0822 39° 20' 39.06" RT 21.45'41.20'60.00'3.72'P.C. 42+03.58 P.C.C. 42+44.79 N 61° 38' 29.23" W N 22° 17' 50.17" W 43+01.60 715,329.5385 9,140.3883 21° 26' 48.64" RT 56.81'112.30'300.00'5.33'P.C.C. 42+44.79 P.T. 43+57.08 N 22° 17' 50.17" W N 0° 51' 01.53" W REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "SECL-116"30+54.42 715,050.5443 9,139.8055 02° 19' 54.76" LT 6.82'13.63'335.00'0.07'P.C. 30+47.60 P.R.C. 30+61.23 N 0° 45' 08.24" E N 1° 34' 46.52" W 30+89.73 715,085.8427 9,138.8321 31° 48' 30.91" RT 28.49'55.52'100.00'3.98'P.R.C. 30+61.23 P.T. 31+16.75 N 1° 34' 46.52" W N 30° 13' 44.39" E 31+54.91 715,143.4365 9,172.3915 36° 39' 25.63" RT 16.56'31.99'50.00'2.67'P.C. 31+38.35 P.C.C. 31+70.34 N 30° 13' 44.39" E N 66° 53' 10.02" E 32+71.93 715,189.8183 9,281.0591 22° 58' 10.90" RT 101.59'200.45'500.00'10.22'P.C.C. 31+70.34 P.T. 33+70.79 N 66° 53' 10.02" E N 89° 51' 20.93" E REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "NWCL-116"10+42.28 715,248.7266 8,885.2715 09° 39' 59.09" RT 42.28'84.36'500.00'1.78'P.C. 10+00.00 P.R.C. 10+84.36 N 89° 49' 53.64" E S 80° 30' 07.27" E 11+44.34 715,231.8516 8,986.1341 26° 59' 08.13" LT 59.99'117.75'250.00'7.10'P.R.C. 10+84.36 P.C.C. 12+02.10 S 80° 30' 07.27" E N 72° 30' 44.61" E 12+21.49 715,255.7040 9,061.8413 42° 23' 29.18" LT 19.39'36.99'50.00'3.63'P.C.C. 12+02.10 P.T. 12+39.10 N 72° 30' 44.61" E N 30° 07' 15.43" E 12+86.56 715,313.5283 9,095.3892 42° 10' 33.20" LT 34.71'66.25'90.00'6.46'P.C. 12+51.85 P.R.C. 13+18.10 N 30° 07' 15.43" E N 12° 03' 17.78" W 13+59.40 715,387.8548 9,079.5161 11° 12' 16.25" RT 41.30'82.33'421.00'2.02'P.R.C. 13+18.10 P.T. 14+00.43 N 12° 03' 17.78" W N 0° 51' 01.52" W REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "SWCL-116"20+54.45 715,190.0454 8,846.4502 08° 32' 22.72" RT 52.26'104.33'700.00'1.95'P.C. 20+02.18 P.T. 21+06.51 N 86° 21' 21.74" E S 85° 06' 15.54" E 22+12.67 715,176.5258 9,004.2890 24° 59' 06.87" RT 22.16'43.61'100.00'2.42'P.C. 21+90.51 P.T. 22+34.12 S 85° 06' 15.54" E S 60° 07' 08.67" E 22+76.56 715,144.3430 9,060.2998 43° 33' 21.51" RT 23.97'45.61'60.00'4.61'P.C. 22+52.59 P.C.C. 22+98.20 S 60° 07' 08.67" E S 16° 33' 47.16" E 23+43.88 715,077.5818 9,080.1553 17° 18' 55.40" RT 45.68'90.66'300.00'3.46'P.C.C. 22+98.20 P.T. 23+88.87 S 16° 33' 47.16" E S 0° 45' 08.24" W BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 37 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.ALN.116.01.dgn5/24/2021 09:43:39 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 ROUNDABOUT ALIGNMENT SUMMARY TABLE 6 0 + 0 0 116th St. 116th St. W e s t fie ld Blv d . R a n g e Lin e R d . 8 0 + 0 0 50+00 70+00 Line "WSI-116" P.I. 53+68.66 "WSI-116" P.I. 51+87.09 "WSI-116" Lin e " S S I- 1 1 6 " O.P.C. 33+45.00 "PR-S1A", 4.00' RT. P.T. 53+97.58 "WSI-116" = O.P.C. 33+45.00 "PR-S1A", 7.53' RT. P.C. 50+00.00 "WSI-116" = P.I. 51+97.93 "WSI-116" P.I. 52+15.06 "WSI-116" P.I. 52+53.78 "WSI-116" P.I. 51+64.58 "WSI-116" P.I. 50+21.88 "WSI" O.P.O.T. 105+91.11 "PR-RL1", 5.00' LT. P.O.T. 62+55.71 "SSI-116" = O.P.O.T. 105+91.11 "PR-RL1", 5.00' RT. P.O.T. 60+00.00 "SSI-116" = P.I. 61+84.66 "SSI-116" P.I. 61+26.87 "SSI-116" P.I. 61+44.64 "SSI-116" P.I. 61+15.78 "SSI-116" P.I. 60+84.43 "SSI-116" P.I. 60+45.33 "SSI-116" Line "ESI-116" O.P.O.T. 38+80.28 "PR-S1A", 5.00' LT. P.C. 70+00.00 "ESI-116" = P.I. 70+67.67 "ESI-116" P.I. 73+16.28 "ESI-116" P.I. 71+65.54 "ESI-116" P.I. 71+99.30 "ESI-116" P.I. 72+26.14 "ESI-116" P.I. 72+09.23 "ESI-116" Lin e " NS I - 1 1 6 " P.I. 81+82.20 "NSI-116" P.I. 82+27.91 "NSI-116" P.I. 81+66.44 "NSI-116" P.I. 81+57.24 "NSI-116" P.I. 81+24.33 "NSI-116" P.I. 80+47.32 "NSI-116" O.P.T. 109+98.97 "PR-RL1", 9.00' RT. P.O.T. 83+21.51 "NSI-116" = O.P.O.T. 110+11.79 "PR-RL1", 9.00' LT. P.C. 80+00.00 "NSI-116" = O.P.O.T. 38+80.28 "PR-S1A", 5.00' RT. P.O.T. 74+20.84 "ESI-116" = RJCNRM MJM MJM N/A ROUNDABOUT ALIGNMENT PLAN 1"=30' 116TH ST. - SPLITTER ISLANDS REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "NSI-116"80+47.32 715,382.1387 9,100.6032 13° 29' 41.19" LT 47.32'94.21'400.00'2.79'P.C. 80+00.00 P.R.C. 80+94.21 S 0° 51' 01.52" E S 14° 20' 42.72" E 81+24.33 715,307.1100 9,119.7909 37° 00' 21.22" RT 30.12'58.13'90.00'4.91'P.R.C. 80+94.21 P.R.C. 81+52.34 S 14° 20' 42.72" E S 22° 39' 38.50" W 81+57.24 715,274.7920 9,106.2980 117° 04' 33.43" LT 4.90'6.13'3.00'2.75'P.R.C. 81+52.34 P.R.C. 81+58.47 S 22° 39' 38.50" W N 85° 35' 05.07" E 81+66.44 715,275.7834 9,119.1374 11° 58' 49.60" RT 7.97'15.89'76.00'0.42'P.R.C. 81+58.47 P.R.C. 81+74.36 N 85° 35' 05.07" E S 82° 26' 05.33" E 81+82.20 715,273.7017 9,134.8117 114° 55' 30.31" LT 7.84'10.03'5.00'4.30'P.R.C. 81+74.36 P.R.C. 81+84.39 S 82° 26' 05.33" E N 17° 21' 35.64" W 82+27.91 715,322.7225 9,119.4872 16° 30' 34.12" RT 43.52'86.44'300.00'3.14'P.R.C. 81+84.39 P.T. 82+70.83 N 17° 21' 35.64" W N 0° 51' 01.53" W REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "WSI-116"50+21.88 715,210.3683 8,878.6882 03° 27' 58.45" RT 21.88'43.74'723.00'0.33'P.C. 50+00.00 P.T. 50+43.74 S 88° 34' 13.99" E S 85° 06' 15.54" E 51+64.58 715,198.1887 9,020.8831 19° 56' 51.13" RT 17.76'35.16'101.00'1.55'P.C. 51+46.82 P.R.C. 51+81.98 S 85° 06' 15.54" E S 65° 09' 24.41" E 51+87.09 715,188.5799 9,041.6373 119° 09' 35.27" LT 5.11'6.24'3.00'2.92'P.R.C. 51+81.98 P.R.C. 51+88.22 S 65° 09' 24.41" E N 4° 18' 59.68" W 51+97.93 715,203.3544 9,040.5221 14° 33' 27.36" RT 9.71'19.31'76.00'0.62'P.R.C. 51+88.22 P.R.C. 52+07.53 N 4° 18' 59.68" W N 10° 14' 27.68" E 52+15.06 715,220.3213 9,043.5874 112° 51' 40.96" LT 7.53'9.85'5.00'4.04'P.R.C. 52+07.53 P.R.C. 52+17.38 N 10° 14' 27.68" E S 77° 22' 46.72" W 52+53.78 715,210.7220 9,000.7142 16° 30' 11.23" RT 36.40'72.30'251.00'2.63'P.R.C. 52+17.38 P.T. 52+89.68 S 77° 22' 46.72" W N 86° 07' 02.04" W 53+68.66 715,213.6637 8,885.8903 07° 07' 08.67" LT 28.99'57.90'466.00'0.90'P.C. 53+39.68 P.T. 53+97.58 N 81° 21' 00.27" W N 88° 28' 08.94" W REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "SSI-116"60+45.33 715,055.7788 9,114.8721 04° 19' 55.20" LT 11.72'23.44'310.00'0.22'P.C. 60+33.61 P.R.C. 60+57.04 N 0° 45' 08.24" E N 3° 34' 46.96" W 60+84.43 715,094.8115 9,112.4302 30° 37' 44.87" RT 27.38'53.46'100.00'3.68'P.R.C. 60+57.04 P.R.C. 61+10.50 N 3° 34' 46.96" W N 27° 02' 57.91" E 61+15.78 715,123.9041 9,127.2852 120° 48' 17.84" LT 5.28'6.33'3.00'3.07'P.R.C. 61+10.50 P.R.C. 61+16.83 N 27° 02' 57.91" E S 86° 14' 40.07" W 61+26.87 715,122.9003 9,111.9926 15° 03' 25.34" RT 10.04'19.97'76.00'0.66'P.R.C. 61+16.83 P.R.C. 61+36.80 S 86° 14' 40.07" W N 78° 41' 54.59" W 61+44.64 715,126.4045 9,094.4581 114° 55' 30.31" LT 7.84'10.03'5.00'4.30'P.R.C. 61+36.80 P.R.C. 61+46.83 N 78° 41' 54.59" W S 13° 37' 24.90" E 61+84.66 715,082.0177 9,105.2157 14° 22' 33.14" RT 37.83'75.27'300.00'2.38'P.R.C. 61+46.83 P.T. 62+22.10 S 13° 37' 24.90" E S 0° 45' 08.24" W REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "ESI-116"70+67.67 715,224.9177 9,320.5015 15° 24' 51.17" LT 67.67'134.51'500.00'4.56'P.C. 70+00.00 P.R.C. 71+34.51 S 89° 51' 20.93" W S 74° 26' 29.76" W 71+65.54 715,198.4474 9,225.4291 38° 02' 16.66" RT 31.02'59.75'90.00'5.20'P.R.C. 71+34.51 P.R.C. 71+94.26 S 74° 26' 29.76" W N 67° 31' 13.58" W 71+99.30 715,212.2331 9,192.1138 118° 23' 42.68" LT 5.03'6.20'3.00'2.86'P.R.C. 71+94.26 P.R.C. 72+00.46 N 67° 31' 13.58" W S 5° 54' 56.26" E 72+09.23 715,198.5077 9,193.5359 13° 09' 36.84" RT 8.77'17.46'76.00'0.50'P.R.C. 72+00.46 P.R.C. 72+17.92 S 5° 54' 56.26" E S 7° 14' 40.58" W 72+26.14 715,181.6563 9,191.3938 117° 22' 46.33" LT 8.22'10.24'5.00'4.62'P.R.C. 72+17.92 P.R.C. 72+28.16 S 7° 14' 40.58" W N 69° 51' 54.25" E 73+16.28 715,214.8204 9,281.8479 19° 59' 26.68" RT 88.12'174.45'500.00'7.71'P.R.C. 72+28.16 P.T. 74+02.62 N 69° 51' 54.25" E N 89° 51' 20.93" E BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 38 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.ALN.116.02.dgn5/24/2021 09:43:40 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 R a n g e Lin e R d . R a n g e Lin e R d . Medical Dr. 20+00 50+00 10+00 40+00 70+00 6 0 + 0 0 3 0 + 0 0 8 0 + 0 0 O.P.O.T. 115+54.74 "PR-RL1", 24.00' LT. P.T. 11+22.05 "NWCL-116" = P.I. 11+13.58 "NWCL-MED" P.I. 50+73.10 "WSI-MED" P.I. 10+28.07 "NWCL-MED" O.P.C. 11+20.72 "PR-S2A", 14.45' LT. P.O.T. 10+00.00 "NWCL-MED" = O.P.C. 11+20.72 "PR-S2A", 14.55' RT. P.O.T. 20+00.00 "SWCL-MED" = Lin e "N S I - ME D " Line "NWCL-MED" Line "WSI-MED" Line "SWCL-MED" P.I. 10+78.48 "NWCL-MED" P.I. 50+59.65 "WSI-MED" P.I. 50+51.21 "WSI-MED" P.I. 20+33.11 "SWCL-MED" P.I. 20+67.98 "SWCL-MED" P.I. 21+25.36 "SWCL-MED" O.P.O.T. 113+36.76 "PR-RL1", 24.00' LT. P.T. 21+73.25 "SWCL-MED" = P.I. 30+66.42 "SECL-MED" P.I. 31+21.86 "SECL-MED" Line "SECL-MED" O.P.O.T. 113+63.20 "PR-RL1", 24.00' RT. P.O.T. 30+00.00 "SECL-MED" = O.P.O.C. 13+42.79 "PR-S2A", 15.93' RT. P.O.T. 31+51.53 "SECL-MED" = Line "NECL-MED" O.P.T. 13+48.99 "PR-S2A", 14.00' LT. P.O.T. 40+00.00 "NECL-MED" = P.I. 40+91.61 "NECL-MED" O.P.O.T. 115+54.74 "PR-RL1", 24.00' RT. P.O.T. 41+36.95 "NECL-MED" = O.P.O.C. 11+25.45 "PR-S2A", 2.44' RT. P.O.T. 50+00.00 "WSI-MED" = O.P.O.C. 11+25.36 "PR-S2A", 2.56' LT. P.O.T. 51+23.29 "WSI-MED" = P.I. 50+89.81 "WSI-MED" P.I. 50+28.66 "WSI-MED" Lin e "S S I - MED " P.I. 60+48.69 "SSI-MED" P.I. 60+52.74 "SSI-MED" P.I. 60+59.83 "SSI-MED" P.I. 60+83.80 "SSI-MED" O.P.O.T. 113+63.20 "PR-RL1", 3.00' RT. P.O.T. 60+00.00 "SSI-MED" = O.P.O.T. 113+63.20 "PR-RL1", 3.00' LT. P.T. 61+05.93 "SSI-MED" = Line "ESI-MED" P.I. 70+49.26 "ESI-MED" P.I. 71+23.28 "ESI-MED" P.I. 70+72.60 "ESI-MED" P.I. 70+95.48 "ESI-MED" P.I. 70+82.01 "ESI-MED" �= 00°20'59" LT. (No Curve Run) O.P.O.C. 13+31.25 "PR-S2A", 2.64' LT. P.I. 70+12.12 "ESI" = O.P.O.C. 13+43.10 "PR-S2A", 3.93' RT. P.O.T. 71+60.79 "ESI-MED" = O.P.O.C. 13+43.24 "PR-S2A", 2.07' LT. P.O.T. 70+00.00 "ESI-MED" = O.P.O.T. 115+54.74 "PR-RL1", 2.97' LT. P.O.T. 80+00.00 "NSI-MED" = O.P.O.T. 115+54.74 "PR-RL1", 3.02' RT. P.O.T. 80+94.82 "NSI-MED" = P.I. 80+33.19 "NSI-MED" P.I. 80+58.31 "NSI-MED" P.I. 80+46.46 "NSI-MED" P.I. 80+44.01 "NSI-MED" P.I. 80+51.96 "NSI-MED" ROUNDABOUT ALIGNMENT SUMMARY TABLE RJCNRM MJM MJM ROUNDABOUT ALIGNMENT PLAN N/A 1"=20' MEDICAL DRIVE REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "NWCL-MED"10+28.07 715,911.3169 9,020.2116 07° 53' 20.77" LT 13.79'27.54'200.00'0.47'P.C. 10+14.28 P.C.C. 10+41.82 N 89° 07' 37.12" E N 81° 14' 16.35" E 10+78.48 715,919.0016 9,070.0699 72° 29' 30.37" LT 36.66'63.26'50.00'12.00'P.C.C. 10+41.82 P.C.C. 11+05.08 N 81° 14' 16.35" E N 8° 44' 45.97" E 11+13.58 715,963.6311 9,076.9621 09° 43' 11.89" LT 8.50'16.96'100.00'0.36'P.C.C. 11+05.08 P.T. 11+22.05 N 8° 55' 12.59" E N 0° 47' 59.30" W REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "SWCL-MED"20+33.11 715,882.3902 9,025.2473 47° 37' 14.26" RT 30.89'58.18'70.00'6.51'P.C. 20+02.22 P.C.C. 20+60.40 N 89° 07' 37.12" E S 43° 15' 08.62" E 20+67.98 715,854.3754 9,051.6033 14° 23' 28.65" RT 7.58'15.07'60.00'0.48'P.C.C. 20+60.40 P.C.C. 20+75.47 S 43° 15' 08.62" E S 28° 51' 39.97" E 21+25.36 715,804.0519 9,079.3388 28° 00' 38.45" RT 49.89'97.78'200.00'6.13'P.C.C. 20+75.47 P.T. 21+73.25 S 28° 51' 39.97" E S 0° 51' 01.53" E REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "SECL-MED"30+66.42 715,847.7406 9,126.6956 60° 52' 39.13" RT 35.26'63.75'60.00'9.59'P.C. 30+31.17 P.C.C. 30+94.92 N 0° 51' 01.53" W N 60° 01' 37.61" E 31+21.86 715,878.8130 9,180.5733 30° 09' 15.50" RT 26.94'52.63'100.00'3.57'P.C.C. 30+94.92 P.T. 31+47.55 N 60° 01' 37.61" E S 89° 49' 06.89" E REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "NECL-MED"40+91.61 715,908.9866 9,125.7865 88° 58' 05.36" RT 44.20'69.88'45.00'18.07'P.C. 40+47.41 P.T. 41+17.28 N 89° 49' 06.89" W N 0° 51' 01.53" W REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "WSI-MED"50+28.66 715,894.3952 9,025.4812 35° 15' 02.56" RT 22.24'43.07'70.00'3.45'P.C. 50+06.42 P.R.C. 50+49.49 N 89° 07' 37.12" E S 55° 37' 20.33" E 50+51.21 715,880.8646 9,045.2586 119° 45' 13.13" LT 1.72'2.09'1.00'0.99'P.R.C. 50+49.49 P.R.C. 50+51.58 S 55° 37' 20.33" E N 4° 37' 26.55" E 50+59.65 715,890.6282 9,046.0483 18° 20' 28.57" RT 8.07'16.01'50.00'0.65'P.R.C. 50+51.58 P.R.C. 50+67.59 N 4° 37' 26.55" E N 22° 57' 55.12" E 50+73.10 715,903.1338 9,051.3477 122° 52' 05.54" LT 5.51'6.43'3.00'3.27'P.R.C. 50+67.59 P.R.C. 50+74.02 N 22° 57' 55.12" E S 80° 05' 49.58" W 50+89.81 715,899.4701 9,030.3621 09° 01' 47.54" RT 15.79'31.52'200.00'0.62'P.R.C. 50+74.02 P.T. 51+05.54 S 80° 05' 49.58" W S 89° 07' 37.12" W REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "SSI-MED"60+48.69 715,829.7011 9,105.9610 100° 09' 51.30" LT 1.20'1.75'1.00'0.56'P.C. 60+47.50 P.R.C. 60+49.25 N 0° 51' 01.53" W S 78° 59' 07.18" W 60+52.74 715,828.8054 9,101.3595 07° 59' 30.12" RT 3.49'6.97'50.00'0.12'P.R.C. 60+49.25 P.R.C. 60+56.22 S 78° 59' 07.18" W S 86° 58' 37.29" W 60+59.83 715,828.4308 9,094.2658 100° 33' 31.14" LT 3.61'5.27'3.00'1.69'P.R.C. 60+56.22 P.R.C. 60+61.49 S 86° 58' 37.29" W S 13° 34' 53.85" E 60+83.80 715,803.2328 9,100.3533 12° 43' 52.32" RT 22.31'44.44'200.00'1.24'P.R.C. 60+61.49 P.T. 61+05.93 S 13° 34' 53.85" E S 0° 51' 01.53" E REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "ESI-MED"70+49.26 715,896.6442 9,162.2933 14° 22' 41.63" RT 8.83'17.57'70.00'0.55'P.C. 70+40.43 P.T. 70+57.99 S 89° 49' 53.64" W N 75° 47' 24.73" W 70+72.60 715,902.3979 9,139.5713 125° 47' 46.77" LT 5.86'6.59'3.00'3.59'P.C. 70+66.74 P.R.C. 70+73.33 N 75° 47' 24.73" W S 21° 35' 11.50" E 70+82.01 715,888.8773 9,144.9208 19° 41' 35.41" RT 8.68'17.19'50.00'0.75'P.R.C. 70+73.33 P.R.C. 70+90.51 S 21° 35' 11.50" E S 1° 53' 36.09" E 70+95.48 715,875.2413 9,145.3716 117° 43' 00.91" LT 4.96'6.16'3.00'2.80'P.R.C. 70+90.51 P.R.C. 70+96.68 S 1° 53' 36.09" E N 60° 23' 23.00" E 71+23.28 715,890.8376 9,172.8145 29° 47' 30.11" RT 26.60'52.00'100.00'3.48'P.R.C. 70+96.68 P.T. 71+48.67 N 60° 23' 23.00" E S 89° 49' 06.89" E REF.P.I.P.I.P.I.DELTA TANGENT ARC CURVE EXTERNAL CURVE BEGIN CURVE END BEARING BEARING LINE STATION NORTHING EASTING LENGTH LENGTH RADIUS LENGTH STATION STATION BACK AHEAD "NSI-MED"80+33.19 715,939.2541 9,098.3679 11° 07' 17.62" RT 9.74'19.41'100.00'0.47'P.C. 80+23.46 P.R.C. 80+42.87 S 0° 51' 46.12" E S 10° 15' 31.50" W 80+44.01 715,928.5504 9,096.4307 97° 34' 49.20" LT 1.14'1.70'1.00'0.52'P.R.C. 80+42.87 P.R.C. 80+44.57 S 10° 15' 31.50" W S 87° 19' 17.70" E 80+46.46 715,928.4087 9,099.4607 04° 19' 57.67" RT 1.89'3.78'50.01'0.04'P.R.C. 80+44.57 P.R.C. 80+48.35 S 87° 19' 17.70" E S 82° 59' 20.03" E 80+51.96 715,927.7370 9,104.9218 100° 33' 31.14" LT 3.61'5.26'3.00'1.69'P.R.C. 80+48.35 P.R.C. 80+53.62 S 82° 59' 20.03" E N 3° 32' 51.17" W 80+58.31 715,936.0220 9,104.4081 02° 41' 16.88" RT 4.69'9.38'199.91'0.06'P.R.C. 80+53.62 P.T. 80+63.00 N 3° 32' 51.17" W N 0° 51' 34.29" W BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 39 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.ALN.MED.01.dgn5/24/2021 09:43:41 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Line "PR-RL1" Line "PR-S1A" P.G. Loc. Line "PR-RL1" P.G. Loc. Line "PR-RL1" P.G. EL. = 819.40 106+99.92 "PR-RL1" 818. 84 2. 0 % P.G. EL. = 819.39 106+99.00 "PR-RL1" 2.0% 818.86 P.G. Loc. Line "PR-S1A" 2.0% 2. 0 % 8 1 8. 7 4 P.G. Loc. Line "PR-S1A" 2 . 0 % 8 2 0 . 0 3 8 1 9 . 4 5 81 9 .45 2.0% 2 .0 % 81 9 .50 2.0%2.0% 820.40 116th Street W e s tfie ld B o u le va r d 2.0%820.50 819.56 35+25.05 "PR-S1A" 10'-0"10 '-0" 82 0.08 82 0 .03 2.0%2 . 0 %82 0 .52 8 2 0 . 5 2 2.0% 2.0% 2.0% 2.0%820.49 820.40 819.42 819.33 819.91 2.0% 820.01 2.0% 2.0% 2.0% 2.0% 818.75 818.69 818.71 818. 65 0.6% 0. 6 % 2. 0 % 2. 0 % 819.60 819 .60 820 .00 819.91 820.18 820.18 820.67 820 .67 2.0% 2.0% 2.0% 2.0% 818 .9081 8.86 8 1 8. 4 0 8 1 8 . 2 5 0.4% 1.5% 819.64 9'-7" 9 ' - 9 " 81 9 .01 819.38 8 ' - 9 " 8'-9 " 819.14 22+47.98 "SWCL-116" 819.26 22+63.00 "SWCL-116" 819.12 22+78.04 "SWCL-116" 818.98 22+93.08 "SWCL-116" 818.96 31+26.52 "SECL-116" 819.08 31+42.56 "SECL-116" 819.21 31+58.62 "SECL-116" 818.98 31+75.20 "SECL-116" P.G. EL. = 819.19 106+70.46 "PR-RL1" P.G. EL. = 819.26 106+80.48 "PR-RL1" P.G. EL. = 819.27 106+81.95 "PR-RL1" P.G. EL. = 819.21 106+72.20 "PR-RL1" P.G. EL. = 818.78 37+15.24 "PR-S1A" 818.93 37+05.69 "PR-S1A" 819.28 36+89.18 "PR-S1A" P.G. EL. = 819.38 34+96.03 "PR-S1A" P.G. EL. = 819.43 35+05.97 "PR-S1A" Low Pt. 818.84 34+76.18 "PR-S1A" 1.5% 1.5% 1.5% 1.5% 1.5% 1.5% - For Curb Alignments, See Roundabout Alignment Plan. - All Dimensions Measured Along Edge of Pavement, Unless Otherwise Noted. - Drainage Structures Shown for Reference Only. - All Elevations Shown at Edge of Pavement, Unless Otherwise Noted. NOTES: Exist. Elev. = 818.61 Exist. Elev. = 818.39 Exist. Elev. = 818.37 Exist. Elev. = 818.18 Exist. Elev. = 818.00 Exist. Elev. = 817.93 1 2 '- 0 " 1 0 '- 0 " 1 0 '- 0 " 1 0 '- 0 " Exist. Elev. = 817.87 Exist. Elev. = 817.76 Exist. Elev. = 817.60 Low Pt. Exist. Elev. = 817.39 8 1 9 . 5 3 8 1 9.6 5 81 9.79 819.93 81 9.81 819. 68 Exist. Elev. = 818.81 Exist. Elev. = 819.16 1.5% 1.5% 819.48 819.51 2.1%2.1 % TJM TJM NRM NRM 1" = 10' N/A RANGE LINE ROAD & 116TH STREET SPOT ELEVATION DETAILS BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 40 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SPE.01.dgn5/24/2021 09:43:43 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 - For Curb Alignments, See Roundabout Alignment Plan. - All Dimensions Measured Along Edge of Pavement, Unless Otherwise Noted. - Drainage Structures Shown for Reference Only. - All Elevations Shown at Edge of Pavement, Unless Otherwise Noted. NOTES: Line "PR-RL1" P.G. Loc. Line "PR-S1A" P.G. Loc. Line "PR-RL1" P.G. Loc. Line "PR-RL1" R a n g e Lin e R d . 116th Street Line "PR-S1A" P.G. Loc. Line "PR-S1A" 2 . 1 % 2 . 0 % 8 1 8 . 9 0 8 1 8 . 8 5 0.5% P.G. EL. = 819.56 35+24.60 "PR-S1A" 2. 0 % 8 1 9 . 0 1 819. 27 2.0% 2.0% 2.0% 819 .38 819 .43 7'-11"7'-11" 2 . 0 % 8 1 9 . 8 6 81 9.86 82 0 .448 2 0 . 4 4 2 . 0 % 2.0% 2.0% 8 2 0 .93 8 2 0 . 9 3 2.0% 2.0% 819.42 819.47 0 .5% 0. 5 % 819.34 2.0% 2.0%82 0 .33 8 1 9 . 9 0 1.5% 2 .0 % 2.0% 2.0% 818 .35 81 8 .20 81 8 .65 820.302.0% 2.0% 819.81 819 .60 2.0% 820 .18 2.0% 820 .67819.64 819.60 2.0% 9 ' - 9 " 9'-7" 820.18 820.67 2.0% 820.40 2.0% 819.91 2.0%819.33 819.22 36+87.54 "PR-S1A" 81 9 .84 818.90 41+97.94 "NECL-116" 819.09 42+12.96 "NECL-116" 819.18 42+28.00 "NECL-116" 819.26 42+43.04 "NECL-116" 819.22 12+45.57 "NWCL-116" 819.17 12+31.55 "NWCL-116" 819.12 12+17.51 "NWCL-116" 819.06 12+03.46 "NWCL-116" P.G. EL. = 819.39 34+97.20 "PR-S1A" P.G. EL. = 819.44 35+07.20 "PR-S1A"P.G. EL. = 818.76 37+16.23 "PR-S1A" P.G. EL. = 819.91 108+79.58 "PR-RL1" P.G. EL. = 819.95 108+89.23 "PR-RL1" P.G. EL. = 819.91 108+79.73 "PR-RL1" P.G. EL. = 819.95 108+89.88 "PR-RL1" Low Pt. 818.81 34+76.18 "PR-S1A" P.G. EL. = 819.83 108+61.03 "PR-RL1"P.G. EL. = 819.84 108+63.17 "PR-RL1" 2.0% 818.91 37+06.18 "PR-S1A" 17'-2"10'-0"10'-0"10'-0"10'-0"10'-0" Exis t. Ele v. = 8 1 7 . 8 9 E xis t. Ele v. = 8 1 7 .6 7 E x is t . E le v. = 8 1 7 .5 9 Ex is t . E le v . = 8 1 7 .5 0 Ex is t . E le v . = 8 1 7 .3 4 Exis t. Ele v. = 8 1 7 . 1 0 Exis t. Ele v. = 8 1 8 . 1 3 1 0 8 + 6 0 . 6 0 "P R -R L1 " 10'-0" 10'-0" 10'-0"Ex is t . E le v . = 8 1 8 .4 9 1 0 8 + 6 6 .4 0 "PR -RL1 " E xist. Ele v. = 8 1 8 .8 2 Exis t. Ele v . = 8 1 9 . 1 3 E xis t. Ele v. = 8 1 9 .4 0 Exis t. Ele v. = 8 1 9 . 4 4 7'-4" 1 0 '- 0 " TJM TJM NRM NRM 1" = 10' N/A RANGE LINE ROAD & 116TH STREET SPOT ELEVATION DETAILS BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 41 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SPE.02.dgn5/24/2021 09:43:43 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Line "PR-RL1" Line "PR-S2A" 826.79 Medical Drive 827.22 826.60 8 2 6 . 4 8 8 2 5 . 5 5 8 2 7 . 1 7 827.37 826.95 826.95 82 7 .47 8 2 7 .5 0 8 28 .4 0 8'-0" 8 '-0 " 826.55 70+90.51 "ESI-MEDICAL" 826.80 826.75 8 ' - 4 " 8'- 5 " 827.00 11+58.04 "PR-S2A", 21.31' LT. 826.72 11+37.85 "PR-S2A", 16.90' LT. 1.5% 8 2 6 . 7 1 8 2 6 .8 6 826.95 827.10 827.00 50+67.59 "WSI-MED" 8 2 6 .6 4 8 2 6 .7 9 826.38 826.53 826.35 11+63.67 "PR-S2A", 22.63' RT. 826.62 50+35.53 "WSI-MED" 9'-3"9'-5" 15'-1" 1 2'- 5 " 1 0'- 6 " 1 0'- 6 " 1 0'-6" 826.30 826.20 825.92 825.60 825.25 824.88 8 2 5 .4 2 6 0 + 5 6 .2 3 "SS I- M E D " 824.42 113+89.57, 32.65' LT. 8 2 4 .9 7 6 0 + 7 2 .8 4 " S S I- M ED" R a n g e Lin e R o a d 8 2 5 . 1 1 6 0 + 3 4 .1 3 "S S I- M ED " 826.55 8 2 4 .6 6 1 1 3 + 9 8 .1 8 , 2 5 .6 2 ' R T. 825.05 825.50 825.92 826.20 826.13 12'-8" 12'-8" 12 '-0" 11 '-8" 11 '-9" 8 2 6 . 3 0 8 2 6 . 2 0 826.05 825.90 826.36 71+07.05 "ESI-MED" 825.67 13+09.61 "PR-S2A", 18.28' RT.1.5% 826.20 13+14.97 "PR-S2A", 17.98' LT. 1.5% 8 2 6 .7 0 8 2 6 .5 5 826.45 826.60 826.81 70+52.61 "ESI-MED" 826.74 826.60 1 3'- 4 " 13'-4" 11'-9" 11'-9" 827.15 827.62 827.20 828.07 828.51 8 2 8 .8 6 8 0 + 6 4 .9 5 " NS I - ME D " 8 2 8 . 8 6 8 0 + 2 9 . 6 5 "N S I- M ED" 828.72 828.87 829.11 1 . 5 %829.26 829.11 1 .5 % 828.84 828.69 828.44 827.30 82 7.9014'-4" 14'-4" 13'-5" 13 '-5" E x . E le v . = 8 2 8 .9 6 1 1 5 + 5 1 . 8 4 , 2 5 . 5 0 ' LT . Ex. Ele v . = 8 2 9 . 3 6 8 0 + 0 7 . 3 1 "NS I- M ED" E x . Ele v. = 8 2 9 .3 7 8 0 + 8 7 .1 0 " N S I - ME D " E x . E le v. = 8 2 8 .9 3 1 1 5 + 4 9 . 6 5 , 2 5 .5 0 ' R T . 8 2 8 . 5 7 1 1 5 + 2 8 .7 5 , 2 2 .0 ' LT . 1.5% 1.5% 1 .7% 8 2 8 .5 7 1 1 5 + 2 7 .0 7 , 2 2 . 0 ' R T . 1.5% Ex. Elev. = 826.39 50+12.96 "WSI-MED" 1.8% 1 .8 %1.8% 1.5% 1.5% 2.0% 3 .0 % 828.17 827.45 1.5 % 1 . 8 % 1 .8 % 1 .0 % 8 2 4 .6 4 1 1 3 + 9 2 .1 7 , 2 2 . 0 0 ' LT . 2.0% 2.0% 2.0% 3. 0 % 2.0%2.0 % 0.0% 1.0% 829.26 0.6% 0 .5 % 826.90 70+66.74 "ESI-MED" 1 .3 % 826.45 827.15 1.5 % 3.0% 2.0% Ex. Ele v. = 8 2 4 . 4 5 6 0 + 9 5 .0 4 "S S I- M ED " 2.0% 824.85 1 .5 % 824.39 824.70 1. 5 % 824.15 824.30 824.85 825.00 824.54 Lin e " P R- RL1 " Match Line 113+94 "PR-RL1" Match Line 113+94 "PR-RL1" 3 . 0 % 827. 00 0. 0% 0.6%826.74 826.34 70+30.55 "ESI-MED" 825.95 71+30.13 "ESI-MED" 825.81 13+10.84 "PR-S2A", 10.88' RT. 8 2 4 . 1 4 1 1 3 + 7 6 .1 0 , 2 5 .5 0 ' R T . 8 2 4 .6 0 6 0 + 1 8 .1 1 "S S I - ME D " 8 2 3 .9 4 1 1 3 + 6 8 .0 6 , 2 7 . 9 8 ' LT . 8 2 4 .0 5 1 1 3 + 6 9 .2 8 , 2 3 . 0 0 ' LT . Low Pt. 826.13 11+39.11 "PR-S2A", 16.80' RT. Low Pt. Ex. Elev. = 826.48 51+10.16 "WSI-MED"Low Pt. 826.74 50+88.07 "WSI-MED" Ex. Elev. = 824.85 13+75.00 "PR-S2A", 14.00' LT. Ex. Elev. = 825.17 13+75.00 "PR-S2A", 14.93' RT. Ex. Elev. = 825.39 13+75.00 "PR-S2A" 825.65 71+60.79 "ESI-MED" 825.70 70+00.00 "ESI-MED" 825.40 14.03' LT. 13+45.00 "PR-S2A" Ex. Elev. = 826.75 Ex. Elev. = 827.11 Ex. Elev. = 826.60827.10 826.95 0.5% 827.84 1.1% 828.28 1.5% 829.40 828.78 828.90 827.77 0 .9 % 827.39 Ex. Elev. = 827.61 1 . 5 % 829.04 828.90 829.54 828.40 1 .2 % 1 6 '-9 " 1 0 ' - 0 " 1 0 ' - 0 " 1 0 '-0 " 8 '-8 " 5 .0 % 5 .0 % 827.88 0.3% Ex. Elev. = 830.2 115+71.54, 45.0' RT. - Top of Curb to be Flush with Existing Sidewalk Elevation as Applicable. - For Curb Alignments, See Roundabout Alignment Plan. - All Dimensions Measured Along Edge of Pavement, Unless Otherwise Noted. - Drainage Structures Shown for Reference Only. - All Elevations Shown at Edge of Pavement, Unless Otherwise Noted. - All Stations and Offsets from Line "PR-RL1", Unless Otherwise Noted NOTES: See Notes for Curb Information Ex. Elev. = 830.1 4 .2 % TJM TJM NRM NRM 1" = 10' N/A RANGE LINE ROAD & MEDICAL DRIVE SPOT ELEVATION DETAILS BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 42 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SPE.03.dgn5/24/2021 09:43:44 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Line "PR-RL1" Medical Drive - For Curb Alignments, See Roundabout Alignment Plan. - All Dimensions Measured Along Edge of Pavement, Unless Otherwise Noted. - Drainage Structures Shown for Reference Only. - All Elevations Shown at Edge of Pavement, Unless Otherwise Noted. - All Stations and Offsets from Line "PR-RL1", Unless Otherwise Noted NOTES: 826.38 826.53 826.35 11+63.67 "PR-S2A", 22.63' RT. 9'-3"9'-5" 15'-1" 1 2'- 5 " 1 0'- 6 " 1 0'- 6" 1 0'-6" 826.30 826.20 825.92 825.60 825.25 824.88 824.42 113+89.57, 32.65' LT. R a n g e Lin e R o a d 824.66 113+98.18, 25.62' RT. 825.05 825.50 825.92 826.20 826.13 12'-8" 12'-8" 12 '-0" 11 '-8" 11'-9" 826.05 825.90 825.67 13+09.61 "PR-S2A", 18.28' RT. Low Pt. 826.13 11+39.11 "PR-S2A", 16.80' RT. Ex. Elev. = 825.17 13+75.00 "PR-S2A", 14.93' RT. Line "PR-S2A" 823.94 113+68.06, 27.98' LT. 824.15 824.30 824.14 113+76.10, 25.50' RT. 824.39 824.54 1.5% 1.5% 826.33 8 2 6.0 5 8 2 5 .7 3 8 2 5 . 3 8 8 2 5. 0 1 824.93 825.38 825.80 826.08 Exist. Elev. = 824.17 Exist. Elev. = 825.16 12'-0" 1 2'-7" 1 2'-0" Exist. Elev. = 824.00 Exist. Elev. = 823.52 Exist. Elev. = 825.40 Exist. Elev. = 825.69 825.36 825.05 824.73 824.28 1.5% 1.5%Exist. Elev. = 824.82 Exist. Elev. = 824.52 826.30 826.14 825.85 Exist. Elev. = 823.51 Exist. Elev. = 823.20 18'-10" 18'-11" Exist. Elev. = 823.27 Exist. Elev. = 823.06 Exist. Elev. = 823.46 Exist. Elev. = 823.55 Exist. Elev. = 823.53 Exist. Elev. = 823.49 Exist. Elev. = 823.51 18'-7" 1 .5 % 1 . 5 % 1 . 5 % 825.50 13+38.55 "PR-S2A", 15.80' RT. 825.34 13+55.00 "PR-S2A", 15.60' RT. 825.68 825.52 825.35 1.5% 1.5% 1.5% 1.5% 1. 5% 1.5 % 1.5 % 20'-0"20'-0"21'-4" Exist. Inlet 822.62 Exist. Inlet 822.76 18'-0" Exist. Elev. = 823.06 Exist. Elev. = 823.47 Exist. Elev. = 824.32 823.89 823.55 Exist. Elev. = 823.20 Exist. Elev. = 823.63 1.0% 823.75 35.34' RT. 14+77.36 "PR-S2A" 823.46 53.88' RT. 14+77.62 "PR-S2A" Parking Addition 1 8 '-6 " grass 1 2 " v c p TJM TJM NRM NRM 1" = 10' N/A RANGE LINE ROAD & MEDICAL DRIVE SPOT ELEVATION DETAILS BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 43 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SPE.04.dgn5/24/2021 09:43:45 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Range Line Rd. Line "PR-RL1"118+00 App. Exist. R/W Temp. R/W Temp. R/W F1 Constr. LimitsConstr. Limits Do Not Disturb Steps Do Not Disturb Handrail 15 Bu ff e r 1 .5 % 37.338 Line "PR-RL1" Range Line Rd. (Typ.) 821.71 821.00 5 . 0 % 1 .5 % Temp. R/W App. Exist. R/W Constr. Limits 832.1 M.E. 60.16' RT. +98.35 834.73 40.00' RT. +01.60 Line "PR-RL1" Range Line Rd. 117+00 Temp. R/W App. Exist. R/W 5 . 0 % 120+00 Line "PR-RL1" 112+00 1 . 5 % 1 . 5 % 8 ' - 0 " 0 . 5 % Range Line Rd. Temp. R/W Constr. Limits App. Exist. R/W 15 15 15 15 - For Curb Alignments, See Roundabout Alignment Plan. - All Dimensions Measured Along Edge of Pavement, Unless Otherwise Noted. - Drainage Structures Shown for Reference Only. - All Elevations Shown at Edge of Pavement, Unless Otherwise Noted. - All Stations and Offsets from Line "PR-RL1", Unless Otherwise Noted NOTES: Range Line Rd. Line "PR-RL1" App. Exist. R/W Constr. Limits 110+50 1 0 '-0 " 8'-0" 45.75' RT. +42.84 830.8 M.E. 833.03 835.00 32.00' RT. +05.13 834.70 32.00' RT. +97.13 833.18 36.03' RT. +75.00 830.96830.94831.0 M.E. 834.7 M.E. 60.50' RT. +54.92 833.7 M.E. 60.33' RT. +26.64 830.8 M.E. 45.78' RT. +29.92 830.8 M.E. 48.81' RT. +15.00 1 .5 % 1 .5 % 1 .5 % 1 .5 % 9 .5 % 1 0 . 5 % Constr. Limits 1 0 '- 0 " 1 0 '- 8 " 1 0 '-8 " 1 .5 % 821.8 M.E. 48.00' RT. +39.45 821.9 M.E. 48.00' RT. +35.75 822.15 5 .0 % 822.07 822.1910'-0"822.18 10'-0" 820.59 35.00' LT. +55.06 6 '-0 " 10'-0" 821.3 M.E. 821.21 1 .8 % 820.82 820.94 820.95 0 .2 % 3 .2 % 841.73 1 .5 % 1 .5 % 841.78 5 .0 % 842.1 M.E. 841.85 9'-9" 842.2 M.E. 45.00' RT. +62.33 841.90841.85 841.73 1 .5 % 1 .5 % 9 .1 % 9 .0 % 841.63 841.75 4'-11" 842.0 M.E. 842.1 M.E. 45.00' RT. +38.46 36.1 M.E.8 36.098 0 .4 % 4 .2 % 836.33 36.218 1 .5 % 36.558 8 '- 0 " 6 '-0 " 1 .5 % 0 .0 %36.818 36.908 1 .5 % 1 .2 % 836.92 837.04 1 .5 % 1 .5 % 837.12 1 . 5 % 37.298 837.41 2 .9 % 5 .2 % 1 .5 % 37.458 36.1 M.E.8 1 . 5 % 37.378 37.498 9 .3 % 1 3 . 5 % 1 .5 % 37.598 37.718 1 4 .4 % 1 .5 % 37.868 37.988 1 4 . 4 % 1 .5 %38.368 38.488 1 0 . 4 % 10'-0" 1 .5 % 1 .5 % 838.83 32.01' LT. +30.00 38.4 M.E.8 840.7 M.E. +35.00 841.2 M.E. +67.00 821.1 M.E. 838.71 838.6 M.E. +20.00 838.1 M.E. +00.0 837.5 M.E. +80.0 837.0 M.E. +60.0 836.3 M.E. +40.0 835.7 M.E. +22.2 836.55 837.33 838.75 838.5 M.E. 834.9 M.E. +05.1 833.8 M.E. +75.0 832.5 M.E. +42.8 831.5 M.E. +15.0 834.6 M.E. +97.1 0 .5 % 6.9% 6.9% 822.06 821.7 M.E. +35.0 821.8 M.E.821.6 M.E. +25.0 822.18 822.30 820.2 M.E. +35.00 820.1 M.E. +45.00 821.0 M.E. 110+69.71 "PR-RL1" Lt. "SIDEWALK TIE IN DETAIL" 118+34.52 "PR-RL1" Lt. "SIDEWALK TIE IN DETAIL" 119+72.29 "PR-RL1" Rt. "SIDEWALK TIE IN DETAIL" 112+39.45 "PR-RL1" Rt. "SIDEWALK TIE IN DETAL" 117+09.60 "PR-RL1" Rt. "SIDEWALK TIE IN DETAIL" 838.68 LEGEND Full Depth HMA Pavement (See Typical Sections) F1 K X T PCCP Truck Apron (See Typical Sections) C C1 F Sidewalk, Concrete, 4 In. (See Carmel Std. Dwg. 10-18) K1 HMA for Approaches (Full Depth Pavement) R 28A Mill 1.5 in. & Resurface R1 HMA Wedge & Level (See Typical Sections) 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D Roll Curb for Truck Apron (See City of Carmel Std. 10-25C) Widening with PCC Base, 6" (See Typical Sections) HMA For Structure Installation, Type C (Full Depth Pavement) Widening with HMA, Typc C (Full Depth Pavement) Raised Pedestrian Crossing (See Miscellaneous Details) PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on Subgrade Treatment Type II 14 Straight Concrete Curb, Modified Curb Ramp, Concrete (See Curb Ramp Details) Shared-Use Path (See Typical Sections) 17 Curb & Gutter, Concrete, Type III 4 Planting Areas (See Landscape Plans) WV PPST PPST PP S T PPST H B 836.08 48344 BRK 1" = 10' RJCJAB NRM NRM SPOT ELEVATION DETAILS N/A BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 44 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SPE.06.dgn5/24/2021 09:43:46 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 Temp. R/W R/W 4'- 0" R 2'-0" R 3'-0" R 3'-0"R 2'-0" 2'- 0" 1 8 ' - 6 " 35.53' RT. +63.43 2'-0" 57.17' RT. +60.80 823.6 M.E. 31.33' RT. +58.52 823.8 M.E. 24.95' RT. +60.59 823.4 M.E. 45.84' RT. +58.72 823.75 35.34' RT. +77.36 Constr. Limits Constr. Limits Temp. R/W 823.64 31.60' RT. +60.53 823.2 M.E. 60.34' RT. +58.91 823.46 53.88' RT. +77.62 823.30 54.07' RT. +63.76 823.0 M.E. 49.73' RT. +00.53 823.5 M.E. 30.07' RT. +00.59 823.5 M.E. 48.98' RT. +22.80 823.67 44.92' RT. +24.67 824.3 M.E. 27.71' RT. +26.09 823.6 M.E. 44.85' RT. +26.67 823.89 28.46' RT. +18.61 1.0% 823.55 45.10' RT. +19.17 A A A 13 131'-6" 2'-0" R 823.53 47.03' RT. +21.00 Medical Drive - All Dimensions Measured Along Edge of Pavement, Unless Otherwise Noted. - Drainage Structures Shown for Reference Only. - All Elevations Shown at Edge of Pavement, Unless Otherwise Noted. - All Stations and Offsets from Line "PR-S2A", Unless Otherwise Noted NOTES: P.G. EL. = 820.85 33+45.00 "PR-S1A" EL. = 820.9 M.E. 33+44.00 "PR-S1A" P.G. EL. = 820.85 33+45.00 "PR-S1A" EL. = 820.9 M.E. 33+44.00 "PR-S1A" 1.5% 8 2 1 .0 3 11 '-0" 7'-11" 10 '-0" 10'-0" 10'-0" 10'-0"10'-0" 2 .0 % 8 2 0 .9 1 2 .0 % 82 0 .74 2.0% 8 20 .56 Profile Grade Line "PR-S1A" 2 .0 % 82 0.38 2.0% 82 0 .21 2.0% 82 0 .09 2.0% 81 9 .88 P.G. EL. = 819.70 34+15.00 "PR-S1A" P.G. EL. = 819.70 34+15.00 "PR-S1A" EL. = 819.4 M.E. 34+15.00 "PR-S1A" EL. = 819.3 M.E. 34+15.00 "PR-S1A" 116th Street P.G. EL. = 820.67 P.G. EL. = 820.50 P.G. EL. = 819.97 P.G. EL. = 819.85 P.G. EL. = 820.14 P.G. EL. = 820.32 7'-0" 81 9 .78 2.0%10'-4" 10 '-0" 10 '-0" 2.0% 81 9 .63 P.G. EL. = 819.63 P.G. EL. = 819.53 P.G. EL. = 819.46 P.G. EL. = 819.40 819.52 LD H CC-TR 1" = 10'-0" N/A PARKING LOT DETAIL RJC NRMNRM JAB BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 45 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SPE.08.dgn5/24/2021 09:43:47 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 X1 X2 X3 13 F 15 13 15 F 10'-0" 10'-0 " 10'-0" 10'-0" 2' - 0 " 2'- 0 " 2'-0" 2'-0" 8'-6" 9' - 9 " 7' - 6 " 6'-10" Detectable Warning Surface (Typ.) 6'-0" 5'-0" 5'- 0 " 6'- 0 " 1. 5 % 1.2% 1. 0 % ROUNDABOUT AT WESTFIELD BLVD. & 116TH ST. CURB RAMP DETAILS X1, X2 & X3 0.6% 1.5% El. 819.23 5.02' LT. 106+72.34 "PR-RL1" El. 819.21 8.70' RT. 106+70.85 "PR-RL1" El. 818.65 34.50' RT. 106+59.55 "PR-RL1" ROUNDABOUT AT RANGE LINE RD. & 116TH ST. CURB RAMP DETAILS X4, X5 & X6 X4 X5 X6 2'-0" 2'- 0 " 2 '-0 " 7'- 1 1 " 6'-10 "5'-4" 5'- 7 " 13 13 15 15 10'-0" 10'-0" 10'-0" 10'-0" 2'- 0 " 0.5% 1. 3 % 1.5% 8 ' - 0 "F F1 12'-0" Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete F1 8'- 0 " ROUNDABOUT AT 116TH ST. & RANGE LINE RD. CURB RAMP DETAILS X7, X8 & X9 X7 X8 X9 Detectable Warning Surface (Typ.)10'-0" 10'-0" 10'- 0" 10'-0" 8' - 0 " 6' - 0 " 6'-0" 5'-0" 1.5% F 2'-0" 2'-0" 2' - 0 " 2' - 0 " 0.4% 1. 0 % 1.2% 0.6% 0.5% F1 Detectable Warning Surface (Typ.) Curb Ramp, Concrete 2'-0" 2'- 0 " 2'- 0 " F 5'- 0 " 6'- 0 " 1. 5 % F1 6 ' - 0 " 8 ' - 0 " 1.5% 1. 2 % 1.5% 10 '-0" 2'-0" 10'-0"Surface (Typ.) Detectable Warning 7'-4" 7'- 1 0 " 5'- 4 " 5'-5" 10'-0" 10'-0" 1.5% Curb Ramp, Concrete X10 X11 X12 ROUNDABOUT AT 116TH ST. & RANGE LINE RD. CURB RAMP DETAILS X10, X11 & X12 Westfield Blvd. Range Line Rd. 116th St. 116th St. El. 818.69 31.56' LT. 106+68.86 "PR-RL1" 818.75818.65 819.19 19.398 19.298 818.71 18.618 18.718 18.678 El. 819.40 7.19' RT. 34+96.36 "PR-S1A" El. 818.86 31.11' RT. 34+88.47 "PR-S1A" 18.828 18.908 18.868 El. 818.80 5.00' RT. 37+15.06 "PR-S1A" 18.408 818.36 El. 818.25 32.14' RT. 37+19.74 "PR-S1A" 18.218 El. 819.41 7.76' LT. 34+97.41 "PR-S1A" El. 818.85 34.38' LT. 34+91.55 "PR-S1A" El. 818.78 5.32' LT. 37+15.88 "PR-S1A" 818.93 819.46 El. 818.20 32.45' LT. 37+27.18 "PR-S1A" 18.358 818.64 818.79 818.31 818.16 18.868 19.048 19.478 819.56 El. 819.97 4.93' LT. 108+89.53 "PR-L1" 19.388 El. 819.43 30.13' LT. 108+99.26 "PR-L1" 819.93 819.29 819.28 19.398 819.34 20.2 M.E.8 820.07 19.938 El. 819.97 5.62' RT. 108+89.01 "PR-L1" 20.058 19.428 El. 819.47 29.88' RT. 108+94.03 "PR-L1" 819.38 819.43 6'- 0 " 818.90 819.29 819.45 818.95 819.34 818.86 818.81 1.5% 1 . 5 % 1 . 5 % 1 . 5 % 820.2 M.E. 54.73' LT. 108+87.28 "PR-RL1" Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete 20.2 M.E.8 820.28 6'-2" 820.20 820.5 M.E. 54.58' LT. 109+07.08 "PR-RL1" 820.19 819.13 8 % 819.09 8% 819.15 820.5 M.E. 44.62' LT. 109+05.68 "PR-RL1" 8% 1 0 '-0 " 820.03 8 % 819.86 819.91 8 % 8% 819.34 819.30 8% 818.69 8 % 818.84 For Additional Details, See INDOT Std. Dwg. E 604-SWCR-14. For Additional Details, See Construction Details. For Additional Details, See Spot Elevations. TOC = Top of Curb M.E. = Match Exist. NOTES: 14 '-1" 11 '-8" 18'R 9'-1" 9' - 9 " 7' - 6 " 8'-1" LEGEND (See Typical Sections) Full Depth HMA Pavement F1 K X T (See Typical Sections) PCCP Truck ApronC C1 F (See Carmel Std. Dwg. 10-18) Sidewalk, Concrete, 4 In. K1 (Full Depth Pavement) HMA for Approaches R 28A Mill 1.5 in. & Resurface R1 (See Typical Sections) HMA Wedge & Level 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D (See City of Carmel Std. 10-25C) Roll Curb for Truck Apron (See Typical Sections) Widening with PCC Base, 6" Type C (Full Depth Pavement) HMA For Structure Installation, (Full Depth Pavement) Widening with HMA, Typc C (See Miscellaneous Details) Raised Pedestrian Crossing Subgrade Treatment Type II PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on 14 Straight Concrete Curb, Modified (See Curb Ramp Details) Curb Ramp, Concrete (See Typical Sections) Shared-Use Path 17 Curb & Gutter, Concrete, Type III 4 (See Landscape Plans) Planting Areas JAB EAK NRM NRM CURB RAMP DETAILS 1"=10'-0" N/A BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 46 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.DS.01.dgn5/24/2021 09:43:48 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 X15 X14 X13 X16 X17 X18 X19 X20 X21 X22 X23 X24 6'-0"10'-0"6'-0" 6'-0"10'-0"6'-0" 6'-0" 10'-0" 6'-0" 6'-0"10'-0"6'-0" 6'-0"10'-0"6'-0" 6'-0"10'-0"6'-0" 6'-0"10'-0"6'-0" Range Line Rd.Range Line Rd. Medical Dr. Medical Dr. 28 28 28 28 28 28 28 28 F F F1 F1 F1 F1 F1 F F1 F1 F1 F1 2'- 0 " 2'-0 " 2 ' - 0 " 2'-0"2'- 0 " 2'- 0 " 2 '-0 " 2 '- 0 "2 ' - 0 " 7.6%1 . 5 % 4.2% 4.2% 1. 5 % 7.8% 2 . 2 % 4.2% 1.5%7.6% 0 . 6 % 7.5%1.5% 4.2 % 1.5% 1 .1 % 8'-0"6'-0" 6'-0" 10'- 11 " 11'-2" 6 '- 0 " 8 '- 0 " 6'-0" 8'-0" 6'-4" 1'-8" 6'-4" 6'-0"1'-11" 7'-6" 2 ' - 4 " 4'- 6 " 4' - 3 " 3 ' - 8 " 6'-0" 8'-0" 3' - 0 " 8' - 0 " 3'- 0 " 8'- 0 " ROUNDABOUT AT RANGE LINE RD. & MEDICAL DR. CURB RAMP DETAILS X13, X14 & X15 ROUNDABOUT AT RANGE LINE RD. & MEDICAL DR. CURB RAMP DETAILS X16, X17 & X18 ROUNDABOUT AT MEDICAL DR. & RANGE LINE RD. CURB RAMP DETAILS X19, X20 & X21 ROUNDABOUT AT MEDICAL DR. & RANGE LINE RD. CURB RAMP DETAILS X22, X23 & X24 El. 826.71 3.94' LT. 11+44.21 "PR-S2A" El. 826.64 2.19' RT. 11+44.58 "PR-S2A" El. 826.38 17.79' RT. 11+45.63 "PR-S2A" El. 826.45 18.86' LT. 13+09.44 "PR-S2A" El. 826.55 5.38' LT. 13+07.31 "PR-S2A" El. 826.20 3.38' RT. 13+05.89 "PR-S2A" El. 825.90 19.19' RT. 13+03.32 "PR-S2A" Surface (Typ.) Detectable Warning Surface (Typ.) Detectable Warning Surface (Typ.) Detectable Warning Surface (Typ.) Detectable Warning 2 '-0 " 6'-0" 8'-0" 6'-0" 8'-0" 3'-0"8 '- 0 " 3 '-0 "8'- 0 " 3'- 0 " 13 13 13 13 13 16 15 15 15 15 13 15 1315 13 15 15 15 13 15 13 15 15 13 15 15 13 13 15 15 1 0 ' - 4 " 3'-4" 3' - 1 " 3'-0" 2' - 9 " 3'-0"8'-0" 9 '-0 " 11 '-7" 7'-8" 9 '- 7 " 1 5 '-3 " 3 .3 % 1.5% 1 .5 % 2.7% 0.9% 5' - 0 " 3' - 0 " 11'-9" 29.118 29.118 El. 829.26 3.02' RT. 115+40.98 "PR-RL1 28.728 El. 828.87 25.50' RT. 115+43.58 "PR-RL1 28.698 El. 828.84 25.91' LT. 115+45.80 "PR-RL1 28.898 29.018 829.50 829.62 28.748 829.11 828.99 828.86 29.168 29.318 26.868 El. 826.95 17.68' LT. 11+43.43 "PR-S2A" 26.798 26.538 827.10 6'-0"10'-0"6'-0" 827.15 27.278 827.72 27.128 0 . 8 % 26.598 26.858 26.978 26.618 1. 0% 26.728 26.308 26.058 26.608 26.708 26.168 2.4% 827.10 El. 829.26 2.96' LT. 115+41.32 "PR-RL1 3 .9 % 24.858 El. 824.70 3.72' LT. 113+80.15 "PR-RL1 25.008 El. 824.85 3.00' RT. 113+81.32 "PR-RL1 El. 824.39 25.50' RT. 113+82.16 "PR-RL1 24.548 824.93 1 . 9 % El. 824.15 29.02' LT. 113+73.99 "PR-RL1 24.308 24.208 24.458 24.578 824.32 24.358 24.478 24.49824.748 824.86 24.618 24.648 24.768 828.78 828.93 824.80 For Additional Details, See INDOT Std. Dwg. E 604-SWCR-14. For Additional Details, See Raised Pedestrian Crossing Details. For Additional Details, See Construction Details. For Additional Details, See Spot Elevations. TOC = Top of Curb M.E. = Match Exist. NOTES: Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete Curb Ramp, Concrete 825.95 825.920.5% 825.85 826.03 826.14 826.30 826.26 10'-11" 6'-0" 826.14 825.09 824.97 825.37 825.25 1 % 1 % 827.60 826.95 5 . 3 % 7'-6" 17 'R 1 2 '-0 " 1 0 ' - 4 " Return Curb Req'd. Return Curb Req'd. Return Curb Req'd. Return Curb Req'd. Return Curb Req'd. LEGEND (See Typical Sections) Full Depth HMA Pavement F1 K X T (See Typical Sections) PCCP Truck ApronC C1 F (See Carmel Std. Dwg. 10-18) Sidewalk, Concrete, 4 In. K1 (Full Depth Pavement) HMA for Approaches R 28A Mill 1.5 in. & Resurface R1 (See Typical Sections) HMA Wedge & Level 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D (See City of Carmel Std. 10-25C) Roll Curb for Truck Apron (See Typical Sections) Widening with PCC Base, 6" Type C (Full Depth Pavement) HMA For Structure Installation, (Full Depth Pavement) Widening with HMA, Typc C (See Miscellaneous Details) Raised Pedestrian Crossing Subgrade Treatment Type II PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on 14 Straight Concrete Curb, Modified (See Curb Ramp Details) Curb Ramp, Concrete (See Typical Sections) Shared-Use Path 17 Curb & Gutter, Concrete, Type III 4 (See Landscape Plans) Planting Areas CURB RAMP DETAILS EAK NRMNRM JAB 1"=10'-0" N/A BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 47 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.DS.02.dgn5/24/2021 09:43:49 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 1 0 5 1 1 0 1 1 5 1 1 0 104+00.00 "PR-RL1" BEGIN PROJECT Westfield Blvd. Lin e "PR -S1 A" 1 1 6 t h S t. 3 5 + 0 0 Range Line Rd. Line "PR-RL1" Range Line Rd. Line "PR-RL1" Me d ic a l D r. P.T. 36+00.50 "PR-S1A" P.C. 107+90.28 "PR-RL1" = App. Exist. R/W App. Exist. R/W App. Exist. R/W A p p. P. L. Ap p . P .L. Ap p . Exist. R/ W App. Exist. R/W App. Exist. R/W Ap p . E xist. R/ W Ap p . E x is t . R/ W App. Exist. R/W App. Exist. R/W Ap p . P .L. Ap p . P .L. Ap p . P .L. App. Exist. R/W App. Exist. R/W Ap p . Exis t. R / W App. Exist. R/W App. P.L. & R/W App. Exist. R/W App. Exist. R/W App . P .L. Ap p . P.L. Ap p . P.L. Ap p . P .L. C ar m el C k. Fl o w 12" rcp 21" rcp 192 " cmp 1 2 " rcp 42" rcp 1 2 " r c p 4" pv c 42" rcp 42" rcp 6" vcp 8" vcp 2" pvc 6" pvc 3" pv c 42" rcp12" rcp 42" rcp 12" rcp 18 " rcp 12" rcp 12 " rcp 21 " rcp 30" rcp 8" pvc 12 " rcp 12" rcp 12" rcp 12" rcp 12" rcp 12" cpp 30" rcp 6" pvc 8 " p vc8" vcp 8" vcp 12" rcp 42" rcp 12 " rcp 12" rcp 12" rcp 12" rcp 12" rcp 12" cpp 30 " rcp 6" pvc 8" p v c8" vcp 8" vcp 12 " rcp 24" rcp 42" rcp 36" rcp to 12" cpp12" pvc12 " vcp 21" rcp 12" vcp 30 " rcp 12 " vcp 6" steel 36" rcp 36" rcp 12 " rcp 12 " rcp 8" cpp 12" rcp 12" rcp 42" rcp 36" rcp 12" rcp 12" rcp 24 " cpp 8" cpp 12 " cpp 12" rcp 12" rcp 36" rcp 12 " rcp 12 " rcp 12" rcp 18 " cpp 36" rcp R/W R/W R/W 1 2 " rcp R/W R/W Ap p . E xist. R/ W App. P.L. & R/W Ap p . P .L. & R /W App. Exist. R/W App. Exist. R/W App. Exist. R/W Temp. R/W Temp. R/W Temp. R/W Li n e " P R - S 2 A " Temp. R/W Temp. R/W Temp. R/W R/W Temp. R/W T e m p . R/ W Temp. R/W Temp. R/W Temp. R/W R/W Temp. R/W Temp. R/W Temp. R/W T e m p . R/ W Temp. R/W R/W R/W R/W R/ W Temp. R/W Temp. R/W 45' RT. +80 +93 44' RT. 59' RT. +07 R/W Temp. R/W LD LD E GM W W W WW W W W W W WW H H H H H H H H H CC -TR WV WV WV CC -TR T H WV C WV H WV H B H H T G P F LEGEND Temporary Inlet Protection Temporary Silt Fence Temporary Seed Mixture Notes: - All areas left undisturbed for more than 7 days shall be Temporary Seeded and Temporary Mulched, unless shown otherwise or as directed by the Engineer. - Inlet Filters shall be installed on all curb inlets (See Specifications) 8 0 7 808 808 8 0 9 809 8 0 9 810 8 1 0 8 1 0 810 8 1 0 811 811 811 811 811 81 1 812 8 1 2 8 1 2 813 813 814 815 815 815 815 816 816 817 817 817 8 1 7 817 818 8 1 8 818 8 1 8 8 1 8 819 81 9 8 1 9 819 8 1 9 8 1 9 819 819 8 1 9 8 1 9 8 1 9 820 820 820 8 2 0 820 8 2 0 8 2 0 8 2 0 8 2 1 8 2 1 8 2 1 821 819 81 9 8 2 0 8218 2 1 8 2 1 8 2 1 8 2 1 821 821 821 822 8 2 2 823 8 2 3 8 2 3 8 2 3 824 824 824 8 2 5 825 825 826 8 2 6 82 6 8 2 6 827 828 8 3 0 830 8 3 1 8 3 2 8 3 3 8 3 3 8 3 3 8 3 3 8 3 4 83 4 8 3 5 8 3 6 836 836 83 7 838838 8 3 8 839 840 841LD LD LD LD H H H T T H H H CC -TR C W M W V WV W V H B PZZ Z PZZ Z PZZZ PZZ Z PZZZ PZZ Z H H H H T WV LD H C WV G H B PZZ Z PZZZ 836.0848344BRK 1"=30' N/A RJC NRMNRM TJM EROSION CONTROL DETAILS LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 48 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.EC.01.dgn5/24/2021 09:43:51 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 1 2 5 Range Line Rd.Line "PR-RL1" C a rm e l D r. Ap p . P.L. Ap p . P .L. App. Exist. R/W Ap p . P .L. App. Exist. R/W App. Exist. R/W Ap p . P .L. Ap p . P.L. App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W App. Exist. R/W Ap p . E xis t. R/ W Ap p . Ex is t . R / W Ap p . P.L. App. Exist. R/W App. Exist. R/W 1 2" rcp 4" cpp 12" rcp 12 " rcp 36" rcp 12 " rcp 12 " rcp 1 2 " r c p 42 " rcp 12 " rcp 12" rcp 4" cpp 36" rcp 12 " rcp 12 " cmp 36" rcp 12 " rcp 36" rcp 1 2 " r c p 12 " rcp 30" rcp 36" rcp 30" rcp 12 " rcp 12 " rcp App. Exist. R/W App. Exist. R/W Temp. R/W Temp. R/W 122+12.93 "PR-RL1" INCIDENTAL CONSTRUCTION END PROJECT & BEGIN 124+63.91 "PR-RL1" END INCIDENTAL CONSTRUCTION 835 838 840 841 842 842 842 84 3 843844 844 84 4 8 4 5 845 8 4 5 8 4 5 8468 4 6 846 847 8 4 7847 847 847 848 848 848 8 4 8 848 848 8488 4 8 8 4 8 849 8 4 9 849 8 4 9 849 H C WV T C W M G G H H H T H H H H H H TR H WV WV WV WV LEGEND Temporary Inlet Protection Temporary Silt Fence Temporary Seed Mixture Notes: - All areas left undisturbed for more than 7 days shall be Temporary Seeded and Temporary Mulched, unless shown otherwise or as directed by the Engineer. - Inlet Filters shall be installed on all curb inlets (See Specifications) 1"=30' N/A RJC NRMNRM TJM EROSION CONTROL DETAILS LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 49 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.EC.02.dgn5/24/2021 09:43:52 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 116th Street 116th Street R a n g e Lin e Rd . Line "PR-S1A" Line "P R-RL1 " P.T. 36+00.50 "PR-S1A" P.C. 107+90.28 "PR-RL1" = 3 5 W e s tfie ld B lv d . 8" pvc 12" rcp 12" rcp 8" vcp 8" vcp3" pvc 8" pvc 4" pv c 6" pvc 12 " cpp 1 2 " c pp 12" cpp 12 " rcp 12 " rcp 12 " rcp 12" rcp 12 " rcp 12" rcp 18" rcp 6" vcp 21" rcp 8" vcp 4 2 " rc p 42 " rcp 1 2 " rcp 42 " rcp 42 " rcp 30 " rcp 8" pvc 12 " rcp 12" rcp 12" rcp 48" rcp 12" rcp 42" rcp 1 2" rc p 8" pv c 8" pvc 6" pvc3" pvc 2" pv c 12 " rcp 12" rcp 1 2 " cp p Ap p . P .L. Ap p . P . L. App. Exist. R/W App. Exist. R/W App. Exist. R/W Ap p . E x is t . R/ W Ap p . Ex is t . R / W Ap p . Ex is t . R / W App . P .L. App. Exist. R/W App. P.L. & R/W Ap p . Ex is t . R / W Ap p . P .L. & R/ W R/W R/W App. Exist. R/W Ap p . P .L. Ap p . P . L. Ap p . P .L. App. Exist. R/W App. Exist. R/W App. Exist. R/W 39+55.00 "PR-S1A" END CONSTRUCTION 32+80.00 "PR-S1A" BEGIN CONSTRUCTION Te m p . R / W Temp. R/W T e m p . R/ W App. Exist. R/W Temp. R/W R/W R/W 58' RT. +73 59' RT. +56 49' RT. +55 49' RT. +08+96 49' RT. 49' RT. +76 50' RT. +07 41' RT. +38 51' LT. +83 56' LT. +21 R/W A/C A/C A/C A/C LD LDLD LD LD EM EM EM EME GM W W W W W W W W W W W W W W T T T H H H H H H H H H CC-TR C WV WV WV WV WV CC-TR T H WV C WV H T H EM T T EM G H H H T G PF LEGEND Temporary Inlet Protection Temporary Silt Fence Temporary Seed Mixture Notes: - All areas left undisturbed for more than 7 days shall be Temporary Seeded and Temporary Mulched, unless shown otherwise or as directed by the Engineer. - Inlet Filters shall be installed on all curb inlets (See Specifications) 8 0 9 8 1 0 8 1 1 8 1 2 81 2 812 812 81 3 81 3813813 814 814 814 815 815 815 816 816 8 16 816 817 8 17 8 1 7 817 817 818 8 1 8 818 8 1 8 8 1 8 818818 8 1 8 818 818 818 8 1 9 819 819 819 81 9 819 819 819 8 1 9 81 9 819 8 1 9 819 819 819 820 8 20 8 2 0 820 82 0 820 8 2 0 820 820 8 2 0 820 820 821 821 821 82 1 821 822 822 822 822 822822 823 823 8 2 4 824 824 825 825 825 826 8 2 6 TJM TJM NRM NRM N/A 1" = 30' LINE "PR-S1A" EROSION CONTROL DETAILS BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 50 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.EC.03.dgn5/24/2021 09:43:52 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 JKHJKH EROSION CONTROL TABLE NONE N/A NRM NRM EROSION CONTROL TABLE FROM STATION TO STATION LO C AT I O N F E N C E T E M P . S I L T P R O T E C T I O N T E M P . I N L E T M I X T U R E T E M P . S E E D T E M P . M U LC H N O . 2 S T O N E G E O T E X T I L E S T E M P . I N L E T F I LT E R REMARKS LE F T M E D I A N R I G H T LFT EACH LBS TON TON SYS EACH 34+73 X 1 1 34+74 X 1 1 34+80 X 1 1 34+81 X 1 1 35+11 X 1 1 37+03 X 1 1 37+05 X 1 1 38+04 X 1 38+07 X 1 1 38+07 X 1 1 38+07 38+37 X 30 38+12 X 1 1 38+13 X 1 1 38+21 38+82 X 67 38+47 X 1 1 39+59 X 1 1 39+67 X 1 1 "Line PR-S2A"35 1 11+36 X 1 1 11+35 X 1 1 11+62 X 1 1 Totals 404 65 317 7 150 353 48 EROSION CONTROL TABLE FROM STATION TO STATION LO C AT I O N F E N C E T E M P . S I L T P R O T E C T I O N T E M P . I N L E T M I X T U R E T E M P . S E E D T E M P . M U LC H N O . 2 S T O N E G E O T E X T I L E S T E M P . I N L E T F I LT E R REMARKS LE F T M E D I A N R I G H T LFT EACH LBS TON TON SYS EACH "Line PR-RL1"211 5 103+92 106+08 X 216 104+57 X 1 1 104+99 X 1 1 105+81 X 1 1 106+45 X 1 106+79 X 1 1 106+86 X 1 1 108+80 X 1 1 108+98 X 1 1 110+32 X 1 1 110+35 X 1 1 110+36 X 1 110+61 X 1 110+65 X 1 1 111+22 X 1 112+65 X 1 113+92 X 1 1 113+98 X 1 1 114+01 X 1 1 114+06 X 1 1 114+11 X 1 87 FT TO THE RIGHT 114+94 X 1 1 115+36 X 1 115+53 X 1 1 115+54 X 1 1 115+59 X 1 1 115+61 X 1 1 116+06 X 1 116+52 X 1 117+28 X 1 117+84 X 1 117+89 X 1 118+00 X 1 1 118+20 X 1 118+70 X 1 1 120+35 X 1 1 120+36 X 1 1 121+26 X 1 121+33 X 1 121+50 X 1 123+58 X 1 1 123+73 X 1 1 124+21 X 1 1 124+31 X 1 1 "Line PR-S1A"71 1 32+75 X 1 1 32+75 X 1 1 32+76 32+96 X 20 33+07 33+74 71 34+20 X 1 1 34+21 X 1 1 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 51 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.EC.04.dgn5/24/2021 09:43:59 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 M edical D r. Rang e Line Rd. P.O.T. 12+32.76 "PR-S2A" P.O.T. 114+61.91 "PR-RL1"= Line "PR-RL1" Line "PR- S2A" 14+00 11 4 + 00 13+00 F1 F 8'-0" 5'-0" WALL SOIL PARAMETERS (See Special Provisions for Details) A pp. Exist. R/W R/W Tem p. R/W R/W R/W Temp. R/W 2'-0" PLAN Scale: 1"=10'-0"; Contours Intervals 1'-0" ELEVATION - F.F. WALL Scale: 1"=10'-0" Horizontal; 1"=10'-0" Vertical 830 820 810 810 820 830 840 88 .0' R 135'-7" 9'-0"35'-3"6'-9"4'-3"58'-8" Top of Wall LevelTop of Wall El. 825.33 Begin Retaining Wall Existing Ground Top of Wall El. 825.00 End Retaining Wall Pad El. 821.00 Top Leveling 8 2 3 .5 8 2 3 .3 8 2 3 .1 8 2 3 .6 8 2 3 .6 8 2 3 .6 8 2 3 .8 8 2 4 .0 8 2 4 .1 8 2 4 .3 Wall Turning Point Wall Turning PointWall Turning Point 55.51' RT. 12+75.26 "PR-S2A" Begin Retaining Wall 35.14' RT. 13+12.54 "PR-S2A" Turning Point 28.44' RT. 13+13.65 "PR-S2A" P.C. Turning Point 46°18'46" 42°54'13" 19°20'3" 84°45'57" 1°56'3" R.F. R et aining W all R.F. Retaining Wall F.F. Retaining Wall F.F. R etaining W all 56.82' RT. 12+84.17 "PR-S2A" Turning Point 26.02' RT. 14+02.03 "PR-S2A" End Retaining Wall 57.76' RT. +73.45 "PR-S2A" C on str. Limit s 13A Constr. Limits 13 A 6"1'-6" 6" 1'-6" P.C. Wall Turning Point 21'-8" (Rad.) P.T. Wall Point 823 823 824 824 825 825 825 8 25 826 826 827 828 829 83 0 824 825 El. 825.33 Top of Wall Top of Wall (Along R.F.) (Along R.F.) 15 1.5% 1.5 % 15 5'-0"2'-0" 4 1 Backfill Type 3Structure (Coarse Aggregate, No. 8)Aggregate for Drainage Fill 6"1'-0" H Top Leveling Pad El. Aggregate Leveling Pad (Slope to Drain)*6" Ø Perf. Pipe Block Cap* Modular F.F.R.F. Top of Wall El. Block Wall* Modular 1'-0" A Exist. Pavement * Per Block Wall Manufacturers Recommendations. NOTE: 13 3'-0" 8 2 5 .1 4 8 2 5 .2 8 8 2 5 .8 0 8 2 3 .3 8 2 5 .6 0 8 2 5 .4 4 8 2 4 .7 5 8 2 5 .6 1 8 2 5 .7 2 8 2 3 .6 8 2 5 .6 5 8 2 5 .4 7 8 2 5 .3 4 8 2 5 .0 6 El. 826.00 Top of Wall Top of Wall Level El. 826.00 Top of Wall Line El. Prop. Ground Pad El. 821.67 Top Leveling 14'-8"44'-0" 8 " No. 53 Base on Geotextiles 6" Compacted Aggregate Subgrade Treatment, Type IC 6" ( Min .) 2 '-0 " " = 1'-0"83Scale: B MODULAR BLOCK WALL SECTION B-B BA A 1.5% 4 1 Backfill Type 3Structure (Coarse Aggregate, No. 8) Aggregate for Drainage Fill 6"1'-0" H Top Leveling Pad El. Aggregate Leveling Pad (Slope to Drain)*6" Ø Perf. Pipe Block Cap* Modular F.F.R.F. Top of Wall El. Block Wall* Modular 1'-0" A F1 Exist. Pavement * Per Block Wall Manufacturers Recommendations. NOTE: 13 3'-0" No. 53 Base on Geotextiles 6" Compacted Aggregate Subgrade Treatment, Type IC Line El. Prop. Ground 6" ( M in . ) 2 '- 0 " " = 1'-0"8 3Scale: MODULAR BLOCK WALL SECTION A-A Varies8'-0" (12:1 Max.) Varies A pp. Exist. R/W App . Exist. R/W Tem p. R/W (1 2:1 Max.) Varies SLEEVE DETAIL Not to Scale Vertical Leg Struts Cantilever Base Rear Sleeve Half Lid Front Sleeve Half 12"Ø x 24" Deep (See Special Provisions for Details) 1.5% F 3 '-6 " ( M in . )1'-0"1'-0" 1/2" Expansion Joint Material Req'd. Btwn. Handrail Post 4" Conc. Sidewalk Req'd. Prop. Ground Line El. 12"Ø x 24" Deep Sleeve Filled with Class "A" Concrete 1'-0" 27.93' RT. 13+42.69 "PR-S2A" Turning Point 27.78' RT. 13+37.98 "PR-S2A" P.T. Wall Point 89 .0' R R.F. (Along � H and rail) (Post & Sleeve Spa.) 14 Spa. @ 6'-0" = 84'-0" 25.03' RT. +01.76 27.40' RT. +14.07 � Handrail, Decorative � H and r ail, D ecorative Dec orati ve � Han d rail For Additional Details, See Spot Elevation Details Range Line Road and Medical Drive. For Handrail, Decorative Details, See Landscape Details. NOTES: LD H CC - T R W V LEGEND Full Depth HMA Pavement (See Typical Sections) F1 K X T PCCP Truck Apron (See Typical Sections) C C1 F Sidewalk, Concrete, 4 In. (See Carmel Std. Dwg. 10-18) K1 HMA for Approaches (Full Depth Pavement) R 28A Mill 1.5 in. & Resurface R1 HMA Wedge & Level (See Typical Sections) 13 15 16 22Straight Concrete Curb Curb & Gutter, Concrete, Type II 26 Sodding, Nursery Center Curb, Type D Roll Curb for Truck Apron (See City of Carmel Std. 10-25C) Widening with PCC Base, 6" (See Typical Sections) HMA For Structure Installation, Type C (Full Depth Pavement) Widening with HMA, Typc C (Full Depth Pavement) Raised Pedestrian Crossing (See Miscellaneous Details) PCCP for Approaches, 9 in., on Subgrade Treatment Type II PCCP for Approaches, 6 in., on Subgrade Treatment Type II 14 Straight Concrete Curb, Modified Curb Ramp, Concrete (See Curb Ramp Details) Shared-Use Path (See Typical Sections) 17 Curb & Gutter, Concrete, Type III 4 Planting Areas (See Landscape Plans) TJM NRM RJC NRM RETAINING WALL NO. 1 DETAILS AS NOTED NONE, UNLESS NOTED BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 52 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.RET-1.01.dgn5/24/2021 09:44:00 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 116th Street R a n g e Lin e R d . Lin e "PR -S1A " Lin e "PR-RL1" 3 5 W e s t fie ld B lv d . App. Exist. R/W Ap p . Ex is t . R / W Ap p . Exis t. R / W Ap p . E xis t. R / W Ap p . Ex is t . R / W App. Exist. R/W App. Exist. R/W Ap p . P.L. App. Exist. R/W 106+95 "PR-RL1", 42.5' LT. Luminaire No. 3 106+50 "PR-RL1", 37.1' RT. Luminaire No. 5 36+95 "PR-S1A", 43.9' RT. Luminaire No. 6 37+52 "PR-S1A", 33.0' LT. Luminaire No. 7 37+23 "PR-S1A", 64.0' LT. Service Point, "A" Type II (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole (To Be Removed & Salvaged) Exist. Decorative Light Pole 34+65 "PR-S1A", 34.3' RT. Luminaire No. 2 R/W R/W & R / W Ap p . P . L. App. P.L. & R/W App. Exist. R/W R/W P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = R / W 37+34 "PR-S1A", 35.4' RT. Handhole, Type B the Property of The Carmel Street Department. All Removed Decorative Light Poles to remain NOTE: 109+23 "PR-RL1", 31.7' LT. Luminaire No. 10 109+65 "PR-RL1", 35.5' RT. Luminaire No. 11 105+92 "PR-RL1", 35.5' LT. Luminaire No. 4 105+90 "PR-RL1", 33.5' LT. Comm. Handhole, Type A 35+02 "PR-S1A", 39.2' RT. Comm. Handhole, Type A 36+92 "PR-S1A", 73.0' LT. Comm. Handhole, Type C Ap p . P .L. & R / W (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole (To Be Removed) Exist. Light Pole 35+05 "PR-S1A", 40.9' LT. Comm. Handhole, Type B 39+47 "PR-S1A", 43.0' LT. Comm. Handhole, Type A 33+20 "PR-S1A", 35.4' LT. Comm. Handhole, Type A 37+08 "PR-S1A", 40.0' RT. Comm. Handhole, Type B 108+64 "PR-RL1", 46.8' LT. Comm. Handhole, Type B Connect to Prop. Circuit) (To Remain in Place & Exist. Decorative Light Pole 107+01 "PR-RL1", 42.9' LT. Comm. Handhole, Type A 35+29 "PR-S1A", 56.6' RT. Handhole, Type B 33+51 "PR-S1A", 34.0' RT. Luminaire No. 1 35+24 "PR-S1A", 46.6' LT. Luminaire No. 8 108+67.6 "PR-RL1", 43.8' RT. (Exist. Traffic Pole Location) Luminaire No. 9 (To Remain) Exist. Light Pole R/W R/W R/W LD LDLD LD LD EM EME GM W W W W W W W W W W W W T T T H H H H H H H H H H CC-TR C WV WV CC-TR T H WV C WV H T H G H H H T G PF Lighting Circuit Number Service Point A-1 Controller Box (Lighting & Irrigation) (See Carmel Standard Drawings) Handhole (Type as Shown) LEGEND on New Pole w/ 8' Mast Arm and Deco Base (See Carmel Standard Drawings) Proposed 152 W LED Luminaire (2) 4-1C No. 4 CU Conductor in Plastic Duct in Trench (2) 4-1C No. 4 CU Conductor in 3" PVC Schedule 80 Conduit on New 15' Pole and Deco Base (See Carmel Standard Drawings) Proposed 70 W LED Luminaire 1x 4-in. Conduit, PVC, Schedule 40 & 1x 4-in. Conduit, PVC, Schedule 40 with Innerducts (See Carmel Standard Drawings) 1x 4-in. Conduit, PVC, Schedule 80 & 1x 4-in. Conduit, PVC, Schedule 80 with Innerducts (See Carmel Standard Drawings) EMS RJC HRS HRS 1" = 20' N/A 116th ST. AND RANGE LINE RD. LIGHTING DETAILS BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 53 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.LT.01.dgn5/24/2021 09:44:02 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF HA H S .R KIDRAH 11400180 Range Line Rd. Line "PR-RL1" 1 1 0 1 1 5 App. Exist. R/W App. Exist. R/W 113+62 "PR-RL1", 30.5' RT. Luminaire No. 17 App. Exist. R/W App. Exist. R/W App. Exist. R/W M e d ic a l D r . App. P.L. & R/W R/W Lin e "P R- S 2 A" Lin e "P R- S 2 A" 113+94 "PR-RL1", 48.0' LT. Luminaire No. 18 (To Be Removed) Exist. Light Pole 12+70 "PR-S2A", 37.1' RT. Luminaire No. 19 13+29 "PR-S2A", 19.6' RT. Handhole, Type A 13+28 "PR-S2A", 20.8' LT. Luminaire No. 21 11+66 "PR-S2A", 40.6' LT. Luminaire No. 22 115+69 "PR-RL1", 38.2' LT. Luminaire No. 24 (To Be Removed) Exist. Light Pole 111+20 "PR-RL1", 35.5' RT. Luminaire No. 13 111+62 "PR-RL1", 35.5' LT. Luminaire No. 14 111+27 "PR-RL1", 33.0' RT. Luminaire No. 15 112+78 "PR-RL1", 28.6' LT. Luminaire No. 16 115+16 "PR-RL1", 33.2' RT. Luminaire No. 23 116+12 "PR-RL1", 29.5' RT. Luminaire No. 25 110+13 "PR-RL1", 34.1' LT. Comm. Handhole, Type A 114+28 "PR-RL1", 38.4' RT. Comm. Handhole, Type A 11+24 "PR-S2A", 22.0' LT. Handhole, Type A 115+69 "PR-RL1", 32.4' RT. Handhole, Type B 13+41 "PR-S2A", 20.6' LT. Service Point, "B" Type II R/W R/ W R/W R/W App. Exist. R/W R/W Ap p . Ex is t . R / W (To Be Removed) Exist. Light Pole 11+20 "PR-S2A", 20.9' RT. Luminaire No. 20 111+41 "PR-RL1", 33.5' LT. Comm. Handhole, Type A 113+61 "PR-RL1", 29.0' LT. Comm. Handhole, Type A P.O.T. 12+32.76 "PR-S2A" P.O.T. 114+61.91 "PR-RL1"= 11+42 "PR-S2A", 23.0' RT. Comm. Handhole, Type A 11+40 "PR-S2A", 23.6' LT. Comm. Handhole, Type A 115+23 "PR-RL1", 34.5' LT. Comm. Handhole, Type B 115+27 "PR-RL1", 31.4' RT. Comm. Handhole, Type A 115+97 "PR-RL1", 27.2' LT. Comm. Handhole, Type A 12+81 "PR-S2A", 37.0' LT. Comm. Handhole, Type B 13+78 "PR-S2A", 22.9' LT. Comm. Handhole, Type A 110+19 "PR-RL1", 35.5' LT. Luminaire No. 12 Private Light, Relocate Private Light, Relocate LD LD LD LD H H H T T H H H CC-TR C W M W V W V W V W V W V H B H H H H F P Lighting Circuit Number Service Point A-1 Controller Box (Lighting & Irrigation) (See Carmel Standard Drawings) Handhole (Type as Shown) LEGEND on New Pole w/ 8' Mast Arm and Deco Base (See Carmel Standard Drawings) Proposed 152 W LED Luminaire (2) 4-1C No. 4 CU Conductor in Plastic Duct in Trench (2) 4-1C No. 4 CU Conductor in 3" PVC Schedule 80 Conduit on New 15' Pole and Deco Base (See Carmel Standard Drawings) Proposed 70 W LED Luminaire 1x 4-in. Conduit, PVC, Schedule 40 & 1x 4-in. Conduit, PVC, Schedule 40 with Innerducts (See Carmel Standard Drawings) 1x 4-in. Conduit, PVC, Schedule 80 & 1x 4-in. Conduit, PVC, Schedule 80 with Innerducts (See Carmel Standard Drawings) RJCEMS HRS HRS N/A 1"=20' LIGHTING DETAILS RANGE LINE ROAD No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF HA H S .R KIDRAH 11400180 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 54 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.LT.02.dgn5/24/2021 09:44:03 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 Range Line Rd. Line "PR-RL1" 1 2 0 App. Exist. R/W App. Exist. R/W App. Exist. R/WApp. Exist. R/W 117+48 "PR-RL1", 29.5' RT. Luminaire No. 27 117+17 "PR-RL1", 29.5' LT. Luminaire No. 26 120+73 "PR-RL1", 29.5' LT. Luminaire No. 32 122+12.93 "PR-RL1" END PROJECT App. Exist. R/W 118+66 "PR-RL1", 29.5' RT. Luminaire No. 29 118+23 "PR-RL1", 29.5' LT. Luminaire No. 28 119+48 "PR-RL1", 29.5' LT. Luminaire No. 30 119+71 "PR-RL1", 29.5' RT. Luminaire No. 31 121+79 "PR-RL1", 29.5' LT. Luminaire No. 34 121+02 "PR-RL1", 29.5' RT. Luminaire No. 33 122+38 "PR-RL1", 28.3' RT. Luminaire No. 35 119+25 "PR-RL1", 27.6' LT. Comm. Handhole, Type A 122+55 "PR-RL1", 31.0' LT. Comm. Handhole, Type A App . P .L. Ap p . P.L. Ap p . P.L. Ap p . P.L. App . P .L. Ap p . P.L. T WV H C WV T C W M G H B G H H 836.0848344BRK Lighting Circuit Number Service Point A-1 Controller Box (Lighting & Irrigation) (See Carmel Standard Drawings) Handhole (Type as Shown) LEGEND on New Pole w/ 8' Mast Arm and Deco Base (See Carmel Standard Drawings) Proposed 152 W LED Luminaire (2) 4-1C No. 4 CU Conductor in Plastic Duct in Trench (2) 4-1C No. 4 CU Conductor in 3" PVC Schedule 80 Conduit on New 15' Pole and Deco Base (See Carmel Standard Drawings) Proposed 70 W LED Luminaire 1x 4-in. Conduit, PVC, Schedule 40 & 1x 4-in. Conduit, PVC, Schedule 40 with Innerducts (See Carmel Standard Drawings) 1x 4-in. Conduit, PVC, Schedule 80 & 1x 4-in. Conduit, PVC, Schedule 80 with Innerducts (See Carmel Standard Drawings) RJCEMS HRS HRS N/A 1"=20' LIGHTING DETAILS RANGE LINE ROAD BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 55 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.LT.03.dgn5/24/2021 09:44:04 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF HA H S .R KIDRAH 11400180 Lin e " PR -RL1 " R a n g e Lin e R d . Ap p . E xist. R / W Ap p . E xist. R/ W 1 2 5 + 0 0 122+55 "PR-RL1", 31.0' LT. Comm. Handhole, Type A Carmel Dr. Carmel Dr. (To Remain in Place) Exist. Decorative Light Pole (To Remain in Place) Exist. Decorative Light Pole App. Exist. R/W See Carmel Std. Dwg. 10-43A 122+67 "PR-RL2", 42.2' Rt. (To Be Relocated on New Pole Foundation) Exist. Decorative Light Pole App. Exist. R/W App. Exist. R/W App. Exist. R/W Ap p . E xis t. R / W Ap p . Exis t. R / W POINT SERVICE TYPE BREAKER MAIN 100 AMP CIRCUIT BRANCH A II 30 AMP BREAKER CIRCUIT BRANCH DROPE (%) VOLTAGE MAX 60 AMP SERVICE POINT AMP TABLE (LIGHTING) A-1 (RECEPTACLE) A-2 B II 100 AMP (LIGHTING) B-1 (RECEPTACLE) B-2 30 AMP 60 AMP 5.58 7.42 1.55 3.77 8.50 7.92 1.02 3.35 (Black) AMPS COMPUTED (Red) AMPS COMPUTED 11.43 16.00 22.57 20.57 WV WV WV H H T H H H H TR T WV WV WV WV Lighting Circuit Number Service Point A-1 Controller Box (Lighting & Irrigation) (See Carmel Standard Drawings) Handhole (Type as Shown) LEGEND on New Pole w/ 8' Mast Arm and Deco Base (See Carmel Standard Drawings) Proposed 152 W LED Luminaire (2) 4-1C No. 4 CU Conductor in Plastic Duct in Trench (2) 4-1C No. 4 CU Conductor in 3" PVC Schedule 80 Conduit on New 15' Pole and Deco Base (See Carmel Standard Drawings) Proposed 70 W LED Luminaire 1x 4-in. Conduit, PVC, Schedule 40 & 1x 4-in. Conduit, PVC, Schedule 40 with Innerducts (See Carmel Standard Drawings) 1x 4-in. Conduit, PVC, Schedule 80 & 1x 4-in. Conduit, PVC, Schedule 80 with Innerducts (See Carmel Standard Drawings) RJCEMS HRS HRS N/A 1"=20' LIGHTING DETAILS RANGE LINE ROAD LUMINAIRE TABLE: SERVICE B LUMINAIRE NO.17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 LUMINAIRE TYPE (SEE LEGEND BELOW)LED LED LED LED LED LED LED LED POST POST POST POST POST POST POST POST POST POST POST FOUNDATION TYPE (SEE LEGEND BELOW)STD30 STD30 STD30 STD30 STD30 STD30 STD30 STD30 STD18 STD18 STD18 STD18 STD18 STD18 STD18 STD18 STD18 STD18 STD18 CIRCUIT NUMBER B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 B-1 CIRCUIT CONNECTION B B R R B B R R B B R R B B R R B B R RECEPTACLE YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES CONNECTOR TYPE (PER E807-LTWR-01)I I II II III II II III II II II II II II II II II I I MAST ARM LENGTH (FT)8'8'8'8'8'8'8'8'---------------------- ELEVATION (IN)0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 POLE SET BACK (FT)30.5' RT 48.0' LT 37.1' RT 21.0' RT 20.8' LT 40.6' LT 33.2' RT 38.2' LT 29.5' RT 29.5' LT 29.5' RT 29.5' LT 29.5' RT 29.5' LT 29.5' RT 29.5' LT 29.5' RT 29.2' LT 28.1' RT SHOULDER WIDTH (FT)-------------------------------------- LUMINAIRE E.M.H. (FT)30'30'30'30'30'30'30'30'15'15'15'15'15'15'15'15'15'15'15' NUMBER OF LUMINAIRES 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SET BACK FROM FACE OF CURB LINE "PR-RL1""PR-RL1""PR-S2A""PR-S2A""PR-S2A""PR-S2A""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1" RAMP SEE NOTES LED = 152W, TYPE III, 6000K, COLUMBIA LUMINAIRE STD18 = LIGHT STANDARD FOUNDATION, 18" X 72" WITH DECO WRAP BASE, WASHINGTON POST = 70W, TYPE III, 4000K, WASHINGTON LUMINAIRE STD30 = LIGHT STANDARD FOUNDATION, 30" X 96" WITH DECO WRAP BASE, WASHINGTON B = BLACK CIRCUIT SIG = REUSE EX SIGNAL FOUNDATION R = RED CIRCUIT Use E.M.H. as pole height LUMINAIRE TABLE: SERVICE A LUMINAIRE NO.1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 LUMINAIRE TYPE (SEE LEGEND BELOW)LED LED LED LED LED LED LED LED LED LED LED POST POST POST POST POST FOUNDATION TYPE (SEE LEGEND BELOW)STD30 STD30 STD30 STD30 STD30 STD30 STD30 STD30 STD30 STD30 STD 30 STD 18 STD18 STD18 STD18 STD18 CIRCUIT NUMBER A-1 A-1 A-1 A-1 A-1 A-1 A-1 A-1 A-1 A-1 A-1 A-1 A-1 A-1 A-1 A-1 CIRCUIT CONNECTION R B R B R B R B B R R B B R R B RECEPTACLE YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES CONNECTOR TYPE (PER E807-LTWR-01)I II III I I III III II II II II II II II I I MAST ARM LENGTH (FT)8'8'8'8'8'8'8'8'8'8'8'---------- ELEVATION (IN)0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.5 POLE SET BACK (FT)34.0' RT 34.3' RT 43.5' LT 35.5' LT 37.1' RT 43.9' RT 33.0' LT 46.6' LT 43.8' RT 31.7' LT 35.5' RT 35.5' LT 35.5' RT 35.9' LT 33.0' RT 28.6' LT SHOULDER WIDTH (FT)-------------------------------- LUMINAIRE E.M.H. (FT)30'30'30'30'30'30'30'30'30'30'30'15'15'15'15'15' NUMBER OF LUMINAIRES 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 SET BACK FROM FACE OF CURB LINE "PR-S1A""PR-S1A""PR-RL1""PR-RL1""PR-RL1""PR-S1A""PR-S1A""PR-S1A""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1""PR-RL1" RAMP SEE NOTES LED = 152W, TYPE III, 6000K, COLUMBIA LUMINAIRE STD18 = LIGHT STANDARD FOUNDATION, 18" X 72" WITH DECO WRAP BASE, WASHINGTON POST = 70W, TYPE III, 4000K, WASHINGTON LUMINAIRE STD30 = LIGHT STANDARD FOUNDATION, 30" X 96" WITH DECO WRAP BASE, WASHINGTON B = BLACK CIRCUIT SIG = REUSE EX SIGNAL FOUNDATION R = RED CIRCUIT Use E.M.H. as pole height No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF HA H S .R KIDRAH 11400180 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 56 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.LT.04.dgn5/24/2021 09:44:14 AMjhofman Ind ia na_ Sh a de .tbl Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 A/ C A/ C A/ C A/ C E M E M E M E M E M O N M O N M O N M O N M O N M O N M O N M O N W W W WW W W W W W W WW W W R B - 0 R B - 0 M O N FF E G M G M R B - 0 M B FF E C C - T R T C E M R B - 0 R B - 0 T BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129HARDSCAPE SHEETS WESTFIELD BLVD 1.6" WIDE INTEGRAL COLORED CONCRETE BAND. SEE HARDSCAPEDETAILS. 2. ASPHALT BLOCK PAVER ON CONCRETE BASE AND BITUMINOUSSETTING BED. PAVER TO BE HANOVER ARCHITECTURAL PRODUCTS 8"x8"x 3” ASPHALT BLOCK PAVER. SEE HARDSCAPE DETAILS FOR PAVERFINISH, COLOR AND PATTERN INFORMATION. 3. ASPHALT BLOCK PAVER CROSSING AT PRIVATE DRIVE. PAVER TO BEHANOVER ARCHITECTURAL PRODUCTS 8"X 8"X 3" ASPHALT BLOCKPAVER. SEE HARDSCAPE DETAILS FOR PAVER FINISH, COLOR ANDPATTERN INFORMATION. 4. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" PLANTINGSOIL MIX. SEE HARDSCAPE DETAILS. 5. CURB RAMP, WITH PAVERS. SEE HARDSCAPE DETAILS ANDENGINEERING PLANS. 6. PLANTING AREA TO RECEIVE 12" PLANTING SOIL MIX. SEE LANDSCAPEPLANS FOR PLANTS AND SOIL MIX DETAILS. 7. (NOT USED) 8. ASPHALT MULTI-USE TRAIL; SEE CARMEL STANDARD DRAWING 9. MANUFACTURER RECOMMENDED GRASS PAVER EDGE RESTRAINT. 10. CONCRETE CURB RAMP, SEE CURB RAMP DETAILS. 11. CONCRETE SIDEWALK, SEE CARMEL STANDARD DRAWING 10-18 12. DECORATIVE HAND RAIL KEYNOTES ALTERNATE BID 1 - SEE TECHNICAL SPECIFICATION FOR DETAILS* * * * * 10 10 10 10 10 R/W R/W R/W R/W R/W 11 11 11 11 R/W 6 6 6 6 6 6 11 11 11 44 57 E M E M G M R B - 0 T T R B - 0 T 58 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129 RANGE LINE ROAD 3 1.6" WIDE INTEGRAL COLORED CONCRETE BAND. SEE HARDSCAPEDETAILS. 2. ASPHALT BLOCK PAVER ON CONCRETE BASE AND BITUMINOUS SETTING BED. PAVER TO BE HANOVER ARCHITECTURAL PRODUCTS 8"x8"x 3” ASPHALT BLOCK PAVER. SEE HARDSCAPE DETAILS FOR PAVERFINISH, COLOR AND PATTERN INFORMATION. 3. ASPHALT BLOCK PAVER CROSSING AT PRIVATE DRIVE. PAVER TO BEHANOVER ARCHITECTURAL PRODUCTS 8"X 8"X 3" ASPHALT BLOCKPAVER. SEE HARDSCAPE DETAILS FOR PAVER FINISH, COLOR ANDPATTERN INFORMATION. 4. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" PLANTINGSOIL MIX. SEE HARDSCAPE DETAILS. 5. CURB RAMP, WITH PAVERS. SEE HARDSCAPE DETAILS ANDENGINEERING PLANS. 6. PLANTING AREA TO RECEIVE 12" PLANTING SOIL MIX. SEE LANDSCAPEPLANS FOR PLANTS AND SOIL MIX DETAILS. 7. (NOT USED) 8. ASPHALT MULTI-USE TRAIL; SEE CARMEL STANDARD DRAWING 9. MANUFACTURER RECOMMENDED GRASS PAVER EDGE RESTRAINT. 10. CONCRETE CURB RAMP, SEE CURB RAMP DETAILS. 11. CONCRETE SIDEWALK, SEE CARMEL STANDARD DRAWING 10-18 12. DECORATIVE HAND RAIL KEYNOTES ALTERNATE BID 1 - SEE TECHNICAL SPECIFICATION FOR DETAILS* * * * * 10 11 6 T H S T R E E T HARDSCAPE SHEETS 5 5 5 5 2 2 2 2 22 2 3 3 3 3 1 1 1 111 1 1 2 5 10 10 1 1 6 T H S T R E E T 4 6 6 6 6 6 6 6 6 6 6 4 4 4 4 4 4 6 6 6 10 11 2 11 1 1 6 11 1 1 EXISTING SIDEWALK TO BEPROTECTED AND PRESERVEDTHROUGH CONSTRUCTION T C C - T R C R B - 0 T C836.0848344BRK 59 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129 RANGE LINE ROAD 3 1.6" WIDE INTEGRAL COLORED CONCRETE BAND. SEE HARDSCAPEDETAILS. 2. ASPHALT BLOCK PAVER ON CONCRETE BASE AND BITUMINOUSSETTING BED. PAVER TO BE HANOVER ARCHITECTURAL PRODUCTS 8"x8"x 3” ASPHALT BLOCK PAVER. SEE HARDSCAPE DETAILS FOR PAVERFINISH, COLOR AND PATTERN INFORMATION. 3. ASPHALT BLOCK PAVER CROSSING AT PRIVATE DRIVE. PAVER TO BEHANOVER ARCHITECTURAL PRODUCTS 8"X 8"X 3" ASPHALT BLOCKPAVER. SEE HARDSCAPE DETAILS FOR PAVER FINISH, COLOR ANDPATTERN INFORMATION. 4. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" PLANTINGSOIL MIX. SEE HARDSCAPE DETAILS. 5. CURB RAMP, WITH PAVERS. SEE HARDSCAPE DETAILS ANDENGINEERING PLANS. 6. PLANTING AREA TO RECEIVE 12" PLANTING SOIL MIX. SEE LANDSCAPEPLANS FOR PLANTS AND SOIL MIX DETAILS. 7. (NOT USED) 8. ASPHALT MULTI-USE TRAIL; SEE CARMEL STANDARD DRAWING 9. MANUFACTURER RECOMMENDED GRASS PAVER EDGE RESTRAINT. 10. CONCRETE CURB RAMP, SEE CURB RAMP DETAILS. 11. CONCRETE SIDEWALK, SEE CARMEL STANDARD DRAWING 10-18 12. DECORATIVE HAND RAIL KEYNOTES ALTERNATE BID 1 - SEE TECHNICAL SPECIFICATION FOR DETAILS* * * * * 1 2 ME D I C A L D R I V E HARDSCAPE SHEETS 3 3 3 22 112 2 2 2 2 2 2 1 1 1 1 1 1 1 1 1 6 6 6 6 66 4 5 5 5 4 4 44 4 4 115 5 5 5 5 5 5 4 4 6 11 10 5 1 11 1 6 6 6 10 11 12 12 M O N T C W M T M O N F P H P P S T P P S T T R 60 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129 1.6" WIDE INTEGRAL COLORED CONCRETE BAND. SEE HARDSCAPEDETAILS. 2. ASPHALT BLOCK PAVER ON CONCRETE BASE AND BITUMINOUSSETTING BED. PAVER TO BE HANOVER ARCHITECTURAL PRODUCTS 8"x8"x 3” ASPHALT BLOCK PAVER. SEE HARDSCAPE DETAILS FOR PAVERFINISH, COLOR AND PATTERN INFORMATION. 3. ASPHALT BLOCK PAVER CROSSING AT PRIVATE DRIVE. PAVER TO BEHANOVER ARCHITECTURAL PRODUCTS 8"X 8"X 3" ASPHALT BLOCKPAVER. SEE HARDSCAPE DETAILS FOR PAVER FINISH, COLOR AND PATTERN INFORMATION. 4. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" PLANTINGSOIL MIX. SEE HARDSCAPE DETAILS. 5. CURB RAMP, WITH PAVERS. SEE HARDSCAPE DETAILS ANDENGINEERING PLANS. 6. PLANTING AREA TO RECEIVE 12" PLANTING SOIL MIX. SEE LANDSCAPEPLANS FOR PLANTS AND SOIL MIX DETAILS. 7. (NOT USED) 8. ASPHALT MULTI-USE TRAIL; SEE CARMEL STANDARD DRAWING 9. MANUFACTURER RECOMMENDED GRASS PAVER EDGE RESTRAINT. 10. CONCRETE CURB RAMP, SEE CURB RAMP DETAILS. 11. CONCRETE SIDEWALK, SEE CARMEL STANDARD DRAWING 10-18 12. DECORATIVE HAND RAIL KEYNOTES ALTERNATE BID 1 - SEE TECHNICAL SPECIFICATION FOR DETAILS* * * * * RANGE LINE ROAD 3 HARDSCAPE SHEETS 3 3 3 3333 33 2 22 2 2 2 2 2 2 2 2 11111 1 1 1 1 1 1 1 1 LINE ''PR-RL1'' 6 6 6 6 6 6 44 11 6 6 6 6 6 DECORATIVE TRAIL TO MATCH PHASE I AND PROSCENIUM IMPROVEMENTS EXISTING SIDEWALK TO BEPROTECTED AND PRESERVEDTHROUGH CONSTRUCTION MB C FFE C EM FFE EM EM EM EM EM BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129 1.6" WIDE INTEGRAL COLORED CONCRETE BAND. SEE HARDSCAPEDETAILS. 2. ASPHALT BLOCK PAVER ON CONCRETE BASE AND BITUMINOUSSETTING BED. PAVER TO BE HANOVER ARCHITECTURAL PRODUCTS 8"x8"x 3” ASPHALT BLOCK PAVER. SEE HARDSCAPE DETAILS FOR PAVERFINISH, COLOR AND PATTERN INFORMATION. 3. ASPHALT BLOCK PAVER CROSSING AT PRIVATE DRIVE. PAVER TO BEHANOVER ARCHITECTURAL PRODUCTS 8"X 8"X 3" ASPHALT BLOCKPAVER. SEE HARDSCAPE DETAILS FOR PAVER FINISH, COLOR ANDPATTERN INFORMATION. 4. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" PLANTINGSOIL MIX. SEE HARDSCAPE DETAILS. 5. CURB RAMP, WITH PAVERS. SEE HARDSCAPE DETAILS ANDENGINEERING PLANS. 6. PLANTING AREA TO RECEIVE 12" PLANTING SOIL MIX. SEE LANDSCAPEPLANS FOR PLANTS AND SOIL MIX DETAILS. 7. (NOT USED) 8. ASPHALT MULTI-USE TRAIL; SEE CARMEL STANDARD DRAWING 9. MANUFACTURER RECOMMENDED GRASS PAVER EDGE RESTRAINT. 10. CONCRETE CURB RAMP, SEE CURB RAMP DETAILS. 11. CONCRETE SIDEWALK, SEE CARMEL STANDARD DRAWING 10-18 12. DECORATIVE HAND RAIL KEYNOTES ALTERNATE BID 1 - SEE TECHNICAL SPECIFICATION FOR DETAILS* * * * * 116TH STREET 2 RA N G E L I N E R O A D 10 HARDSCAPE SHEETS 2 2 2 10 10 10 10 5 5 5 5 3 1 1 1 1 6 6 6 6 6 64 4 44 4 4 4 4 11 11 11 1 11 1 6 11 10 6 6 6 6 6 TIE INTO EXISTING ASPHALTTRAIL; INSTALL NEW PATH FLUSHWITH SMOOTH TRANSITION 8 8 61 A/C A/C A/C A/C GM MB BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129 116TH STREET RA N G E L I N E R O A D 5 HARDSCAPE SHEETS 2 2 2 2 10 10 10 10 10 5 55 3 3 1 1 11 1 4 4 4 4 4 4 6 6 6 6 6 11 11 11 11 6 6 6 4 1 2 10 11 1 8 8 EXISTING SIDEWALK TO BEPROTECTED AND PRESERVEDTHROUGH CONSTRUCTION EXISTING SIDEWALK TO BEPROTECTED AND PRESERVEDTHROUGH CONSTRUCTION EXISTING SIDEWALK TO BEPROTECTED AND PRESERVEDTHROUGH CONSTRUCTION 1.6" WIDE INTEGRAL COLORED CONCRETE BAND. SEE HARDSCAPEDETAILS. 2. ASPHALT BLOCK PAVER ON CONCRETE BASE AND BITUMINOUSSETTING BED. PAVER TO BE HANOVER ARCHITECTURAL PRODUCTS 8"x8"x 3” ASPHALT BLOCK PAVER. SEE HARDSCAPE DETAILS FOR PAVERFINISH, COLOR AND PATTERN INFORMATION. 3. ASPHALT BLOCK PAVER CROSSING AT PRIVATE DRIVE. PAVER TO BEHANOVER ARCHITECTURAL PRODUCTS 8"X 8"X 3" ASPHALT BLOCKPAVER. SEE HARDSCAPE DETAILS FOR PAVER FINISH, COLOR AND PATTERN INFORMATION. 4. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" PLANTINGSOIL MIX. SEE HARDSCAPE DETAILS. 5. CURB RAMP, WITH PAVERS. SEE HARDSCAPE DETAILS ANDENGINEERING PLANS. 6. PLANTING AREA TO RECEIVE 12" PLANTING SOIL MIX. SEE LANDSCAPEPLANS FOR PLANTS AND SOIL MIX DETAILS. 7. (NOT USED) 8. ASPHALT MULTI-USE TRAIL; SEE CARMEL STANDARD DRAWING 9. MANUFACTURER RECOMMENDED GRASS PAVER EDGE RESTRAINT. 10. CONCRETE CURB RAMP, SEE CURB RAMP DETAILS. 11. CONCRETE SIDEWALK, SEE CARMEL STANDARD DRAWING 10-18 12. DECORATIVE HAND RAIL KEYNOTES ALTERNATE BID 1 - SEE TECHNICAL SPECIFICATION FOR DETAILS* * * * * 62 DECORATIVE ASPHALT PAVERS. SEE PAVER PATTERN DETAIL FOR PAVER SIZE AND COLOR. SAND SWEPT 116" JOINTS THICK BITUMINOUS SETTING BED TAC COAT CONC. SLAB W/ 6"X6", 66 WWM 2" Ø CORE DRILLED WEEP HOLES @ 100 SF O.C. * FILL W/ 1/4:" CHIP AGGREGATE, NO FINES (TYP.) COMPACTED #53 COARSE AGGREGATE BASE COMPACTED SUBGRADE 3"3/4" 5" 4" 12" PREFORMED EXPANSION JOINT 34" DIAMETER X 16" SMOOTH DOWEL BAR @ 24" OC. 6" WIDE INTEGRALLY COLORED CONCRETE BAND. COLOR: LM SCOFIELD SG237-1 'SAND BUFF' OR APPROVED EQUAL. FINISH: BROOM PLACE CONCRETE SCORE JOINTS AT 15'-0" OC MAXIMUM. SEE DECORATIVE CONCRETE BAND DETAIL. 8"X8"X3" ASPHALT BLOCK PAVER. COLOR: HANOVER ARCHITECTURAL PRODUCTS #A80037 OR APPROVED EQUAL. FINISH: GROUND PATTERN: RUNNING BOND 8"X8"X3" ASPHALT BLOCK PAVER. COLOR: HANOVER ARCHITECTURAL PRODUCTS #A80013 OR APPROVED EQUAL. FINISH: GROUND PATTERN: RUNNING BOND 7'-4"2'-8"2'-8" C 3'- 6 " 3'- 6 " 6" 6" PAVER PATTERN GENERAL NOTES 1. CONTRACTOR SHALL PREPARE A FULL SIZE MOCK UP MEASURING 8' X 16' PRIOR TO CONSTRUCTION. CONTRACTOR SHALL SEEK OWNER APPROVAL OF MOCK UP PRIOR TO INSTALLATION OF CONCRETE BANDS AND PAVER PATHWAY. 2. DO NOT USE UNIT PAVERS WITH CHIPS, CRACKS, VOIDS, DISCOLORATIONS, AND OTHER DEFECTS THAT MIGHT BE VISIBLE IN FINISHED WORK. 3. TO PREPARE THE DOMINANT PAVER FIELD, MIX ASPHALT PAVERS FROM A MINIMUM OF THREE (3) BUNDLES SIMULTANEOUSLY DRAWING THE PAVER VERTICALLY RATHER THAN HORIZONTALLY, AS THEY ARE PLACED, TO PRODUCE UNIFORM BLEND OF COLORS AND TEXTURES. 4. PROVIDE ASPHALT PAVERS USING JOINT PATTERN AS INDICATED. ADJUST JOINT PATTERN AT PAVEMENT EDGES SUCH THAT CUTTING OF EDGE PAVERS IS MINIMIZED. CUT ALL PAVERS NO SMALLER THAN ONE-THIRD OF A WHOLE PAVER. 5. OVERALL PATTERN SHALL BE CENTERED ALONG THE HORIZONTAL LENGTH OF THE PATH. ACCENT PATTERN SHALL BE ADJUSTED ACCORDINGLY WHERE THE SHARED USE PATH CROSSES PRIVATE DRIVES OR PUBLIC ROADS. SEE HARDSCAPE DETAIL SHEETS FOR PATTERN INTENT. ADJACENT LAWN ADJACENT LAWN 6" WIDE INTEGRALLY COLORED CONCRETE BAND. COLOR: LM SCOFIELD SG237-1 'SAND BUFF' OR APPROVED EQUAL. FINISH: BROOM PLACE CONCRETE SCORE JOINTS AT 15'-0" OC MAXIMUM. SEE DECORATIVE CONCRETE BAND DETAIL. 8"X8"X3" ASPHALT BLOCK PAVER. COLOR: HANOVER ARCHITECTURAL PRODUCTS #A80037 OR APPROVED EQUAL. FINISH: GROUND PATTERN: RUNNING BOND 8"X8"X3" ASPHALT BLOCK PAVER. COLOR: HANOVER ARCHITECTURAL PRODUCTS #A80013 OR APPROVED EQUAL. FINISH: GROUND PATTERN: RUNNING BOND VARIES 2'-8"2'-8"2'-8"2'-8"2'-8"2'-8"2'-8"2'-8"2'-8"2'-8"2'-8"2'-8"2'-8"VARIES PAVER PATTERN GENERAL NOTES 1. CONTRACTOR SHALL PREPARE A FULL SIZE MOCK UP MEASURING 8' X 16' PRIOR TO CONSTRUCTION. CONTRACTOR SHALL SEEK OWNER APPROVAL OF MOCK UP PRIOR TO INSTALLATION OF CONCRETE BANDS AND PAVER PATHWAY. 2. DO NOT USE UNIT PAVERS WITH CHIPS, CRACKS, VOIDS, DISCOLORATIONS, AND OTHER DEFECTS THAT MIGHT BE VISIBLE IN FINISHED WORK. 3. TO PREPARE THE DOMINANT PAVER FIELD, MIX ASPHALT PAVERS FROM A MINIMUM OF THREE (3) BUNDLES SIMULTANEOUSLY DRAWING THE PAVER VERTICALLY RATHER THAN HORIZONTALLY, AS THEY ARE PLACED, TO PRODUCE UNIFORM BLEND OF COLORS AND TEXTURES. 4. PROVIDE ASPHALT PAVERS USING JOINT PATTERN AS INDICATED. ADJUST JOINT PATTERN AT PAVEMENT EDGES SUCH THAT CUTTING OF EDGE PAVERS IS MINIMIZED. CUT ALL PAVERS NO SMALLER THAN ONE-THIRD OF A WHOLE PAVER. 5. OVERALL PATTERN SHALL BE CENTERED ALONG THE HORIZONTAL LENGTH OF THE DRIVEWAY. PATTERN SHALL OCCUR IN REGULAR INTERVALS AS SHOWN ON THE PLAN BELOW. PATTERN SHALL BE ADJUSTED ACCORDINGLY WHERE THE SHARED USE PATH MEETS THE CROSSING PATTERN. SEE SHARED USE PATH PAVER PATTERN DETAIL CROSS WALK PATTERN SHALL ALWAYS END IN THE COLOR #A80013 SO THAT A COLOR DISTINCTION IS PROVIDED BETWEEN THE CROSSING AND THE SHARED USE PATH. THE END BAND WIDTH CAN VARY TO MINIMIZE PAVER CUTS, BUT SHALL BE NO SMALLER THAN 2'-8" IN WIDTH. PRIVATE DRIVEWAY VARIES 8 3 / 4 " M I N . 4. 0 0 0 FINISHED GRADE (OR PAVEMENT) 1/2" RADIUS BOTH SIDES 1/4" WASH 1/4" PREFORMED EXPANSION JOINT W/ BACKER ROD; SELF LEVELING SEALANT IN TOP 12" 34" DIAMETER X 16" SMOOTH DOWEL BAR @ 24" OC. COAT OR WRAP DOWEL TO PREVENT BONDING. 2" MIN. CLEAR, BOTH SIDES INTEGRAL COLORED CONCRETE BAND OR CURB COLOR: LM SCOFIELD #SG 237-1 'SAND BUFF' OR APPROVED EQUAL. FINISH: BROOM SEE PAVER PATTERN DETAIL FOR SCORING/ JOINTING INFORMATION. EQ EQ EQ.EQ. 3" 3' - 0 " 1 14" X 1 14" SOLID STEEL TUBING, POWDER COATED BLACK T.S. 2.1 X 1 14" X 1 14" SOLID STEEL TUBING, POWDER COATED BLACK T.S. 2.1 X 34"" X 34" SOLID STEEL TUBING, POWDER COATED BLACK. METAL PICKETS SHALL BE EQUALLY SPACED WITH AREA BUT SHOULD BE NO GREATER THAN 3' O.C. EMBED HANDRAIL INTO CONCRETE SLEEVE PER DETAILS ON ENGINEERING SHEETS. GENERAL GATE AND FENCING NOTES: 1. THE PANEL WIDTHS MAY VARY DEPENDING ON SITE LOCATION AND OVERALL MODULAR WALL LENGTH. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS PRIOR TO FABRICATION THAT SHOW THE FINAL MEASUREMENTS FOR EACH WALL LOCATION. 2. HANDRAIL PANELS SHALL BE ATTACHED TO MASONRY PIERS IN ACCORDANCE WITH ENGINEERING DETAILS AND CONTRACTOR RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE SHOP DRAWINGS FOR REVIEW AND APPROVAL FOR FENCE AND WALL ATTACHMENTS PRIOR TO INSTALLATION. 3. WHEN CUTTING/DRILLING RAILS OR POSTS ADHERE TO THE FOLLOWING STEPS TO SEAL THE EXPOSED STEEL SURFACES; ·REMOVE ALL METAL SHAVINGS FROM CUT AREA. ·APPLY ZINC-RICH PRIMER TO THOROUGHLY COVER CUT EDGE AND/OR DRILLED HOLE; LET DRY. ·APPLY 2 COATS OF CUSTOM FINISH PAINT MATCHING HANDRAIL COLOR. FAILURE TO SEAL EXPOSED SURFACES PER STEPS 1-3 ABOVE WILL NEGATE WARRANTY. MANUFACTURER RECOMMENDED SPRAY CANS OR PAINT PENS SHALL BE USED TO PRIME AND FINISH EXPOSED SURFACES; IT IS RECOMMENDED THAT PAINT PENS BE USED TO PREVENT OVERSPRAY. BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129HARDSCAPE DETAILS 63 1 DECORATIVE SHARED USE PATH DETAIL 2 INTEGRAL COLORED CONCRETE BAND DETAIL 4 DECORATIVE SHARED USE PATH PATTERN DETAIL 5 DECORATIVE SHARED USE PATH PATTERN AT DRIVEWAYS DETAIL 3 DECORATIVE METAL RAILING VARIES, SEE PLANS SHREDDED HARDWOOD MULCH PER SPECIAL PROVISIONS. KEEP MULCH OFF PLANT MATERIAL PLANTING SOIL MIX, SEE SPECIAL PROVISIONS. CONTRACTOR TO PLACE A MINIMUM OF 36" OF PLANTING SOIL IN MEDIAN. EXISTING SUBGRADE PAVEMENT BASE COURSEPAVEMENT BASE COURSE PAVEMENT GRADE PAVEMENT GRADE 3" 3' - 0 " CONTRACTOR SHALL REMOVE EXISTING SOIL WITHIN THE MEDIAN TO A MINIMUM DEPTH OF 36". MEDIAN SHALL BE FILLED WITH A PLANTING SOIL MIX COMPRISED OF 23 TOPSOIL, 13 MULCH AND SOIL CONDITIONER. PLANTING SOIL MIX SHALL BE FREE FROM SUBSOIL VEGETATION, WEEDS OR ANY EXTRANEOUS OR DELETERIOUS MATERIALS LARGER THAN 1". VARIES, SEE PLANS PLANTING SOIL MIX, SEE SPECIAL PROVISIONS. CONTRACTOR TO PLACE A MINIMUM OF 12" OF PLANTING SOIL IN DESIGNATED PLANTING AREAS. EXISTING SUBGRADE PAVEMENT BASE COURSEPAVEMENT BASE COURSE PAVEMENT GRADE PAVEMENT GRADE 3" 1'- 0 " CONTRACTOR SHALL REMOVE EXISTING SOIL IN DESIGNATED AREAS TO A MINIMUM DEPTH OF 12". MEDIAN SHALL BE FILLED WITH A PLANTING SOIL MIX COMPRISED OF 23 TOPSOIL, 13 MULCH AND SOIL CONDITIONER. PLANTING SOIL MIX SHALL BE FREE FROM SUBSOIL VEGETATION, WEEDS OR ANY EXTRANEOUS OR DELETERIOUS MATERIALS LARGER THAN 1". INSTALL TURF SO THAT FINISH GRADE IS 1-INCH TO 2-INCHES BELOW CURB 6" WIDE INTEGRALLY COLORED CONCRETE BAND. COLOR: LM SCOFIELD SG237-1 'SAND BUFF' OR APPROVED EQUAL. FINISH: BROOM PLACE CONCRETE SCORE JOINTS AT 15'-0" OC MAXIMUM. SEE DECORATIVE CONCRETE BAND DETAIL. CONCRETE CURB, SEE ENGINEERING PLANS AND DETAILS. 8"X8"X3" ASPHALT BLOCK PAVER. COLOR: HANOVER ARCHITECTURAL PRODUCTS #A80013 OR APPROVED EQUAL. FINISH: GROUND PATTERN: RUNNING BOND DETECTABLE WARNING ELEMENT, PAVERS, SEE ENGINEERING PLANS. REFER TO ENGINEERING PLANS AND DETAILS FOR LOCATIONS, DESIGN AND SPOT ELEVATIONS FOR ALL ACCESSIBLE RAMPS. 6" WIDE INTEGRALLY COLORED CONCRETE BAND. COLOR: LM SCOFIELD SG237-1 'SAND BUFF' OR APPROVED EQUAL. FINISH: BROOM PLACE CONCRETE SCORE JOINTS AT 15'-0" OC MAXIMUM. SEE DECORATIVE CONCRETE BAND DETAIL. CONCRETE CURB, SEE ENGINEERING PLANS AND DETAILS. 8"X8"X3" ASPHALT BLOCK PAVER. COLOR: HANOVER ARCHITECTURAL PRODUCTS #A80013 OR APPROVED EQUAL. FINISH: GROUND PATTERN: RUNNING BOND DETECTABLE WARNING ELEMENT, PAVERS, SEE ENGINEERING PLANS. BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129HARDSCAPE DETAILS 64 1 36" PLANTING SOIL DETAIL 2 12" PLANTING SOIL DETAIL 3 CONCRETE RAMPS ASPHALT 28 PS 6 HL66 LB 2 PA6 8 JP 76 LB 37 LB 35 L B 39 LB 35 L B 20 RG2 41 NW 23 LB 46 LB A/ C A/ C A/ C A/ C E M E M M A G M A G FF E G M G M FF E C E M M A G PZ Z Z T 28 PS 6 HL66 LB 2 PA6 8 JP 76 LB 37 LB 39 LB 35 L B 20 RG2 41 NW 23 LB 46 LB P P S T P P S T P P S T C T BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129LANDSCAPE PLANS LINE "PR-RL1" WESTFIELD BLVD 1.TURF GRASS SOD. SEE LANDSCAPE DETAILS FOR PLACEMENT AND MIXINFORMATION. 2. SPADE EDGE. SEE LANDSCAPE DETAILS. 3. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. 4. PLANTING AREA TO RECEIVE A MINIMUM OF 12" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. KEYNOTES LANDSCAPE LEGEND EXISTING SHADE TREE EVERGREEN TREE MULCH BED / TREE RING SHRUBS AND ORNAMENTAL GRASSES DECIDUOUS SHADE TREE MA T C H L I N E : S E E S H E E T 6 9 MATC H L I N E : S E E S H E E T 7 0 MA T C H L I N E : S E E S H E E T 6 9 SOD PERENNIALS 65 G M 10 JP 10 CK 20 HH 17 HH 19 PS 9 R3 8 HL 14 TD 8 CA 14 TD 8 HL 14 TD 8 CA 14 TD 8 HL 9 R3 4 PA6 6 JP 3 PA3 17 RG241 NW 53 LB 38 L B 32 LB 19 LB R B - 0 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129 RANGE LINE ROAD 11 6 T H S T R E E T KEYNOTES LANDSCAPE LEGEND EXISTING SHADE TREE EVERGREEN TREE DECIDUOUS SHADE TREE LANDSCAPE PLANS LINE "PR-RL1" MATCHLINE: SEE SHEET 70 MA T C H L I N E : S E E S H E E T 6 9 MA T C H L I N E : S H E E T 6 7 1. TURF GRASS SOD. SEE LANDSCAPE DETAILS FOR PLACEMENT AND MIXINFORMATION. 2. SPADE EDGE. SEE LANDSCAPE DETAILS. 3. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. 4. PLANTING AREA TO RECEIVE A MINIMUM OF 12" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. MULCH BED / TREE RING SHRUBS AND ORNAMENTAL GRASSES SOD PERENNIALS 66 MATCH L I N E : S E E S H E E T 6 9 5 PA3 3 PA3 18 PK 3 PA3 4 JP 4 JP 5 PA3 4 PA6 12 PS 3 CR11 HH 3 PS 10 LB 13 HH 29 LB 45 LB 9 LB 7 LB 18 HH 29 LB 8 LB 30 LB 25 HH15 PK 4 PK9 JP 17 LB 4 JP T C C - T R T 836.0848344BRK BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129 RANGE LINE ROAD ME D I C A L D R I V E LANDSCAPE PLANS LINE "PR-RL1" KEYNOTES LANDSCAPE LEGEND EXISTING SHADE TREE EVERGREEN TREE DECIDUOUS SHADE TREE MA T C H L I N E : S H E E T 6 8 MA T C H L I N E : S H E E T 6 6 1. TURF GRASS SOD. SEE LANDSCAPE DETAILS FOR PLACEMENT AND MIXINFORMATION. 2. SPADE EDGE. SEE LANDSCAPE DETAILS. 3. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. 4. PLANTING AREA TO RECEIVE A MINIMUM OF 12" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. MULCH BED / TREE RING SHRUBS AND ORNAMENTAL GRASSES SOD PERENNIALS 67 3 PA3 5 PA3 2 PA6 1 PA6 2 CR T C W M T F P H P P S T P P S T T R BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129 RANGE LINE ROAD LANDSCAPE PLANS LINE "PR-RL1" KEYNOTES LANDSCAPE LEGEND EXISTING SHADE TREE EVERGREEN TREE DECIDUOUS SHADE TREE MA T C H L I N E : S H E E T 6 7 1. TURF GRASS SOD. SEE LANDSCAPE DETAILS FOR PLACEMENT AND MIXINFORMATION. 2. SPADE EDGE. SEE LANDSCAPE DETAILS. 3. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. 4. PLANTING AREA TO RECEIVE A MINIMUM OF 12" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. MULCH BED / TREE RING SHRUBS AND ORNAMENTAL GRASSES SOD PERENNIALS 68 MB 19 P S 11 JP 1 GP 41 N W 38 LB 37 LB 35 LB 36 LB 41 N W 23 PK 54 NW 66 LB 29 RG2 PPST PPST W PPST BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129 116TH STREET WE S T F I E L D B L V D LANDSCAPE PLANS KEYNOTES LANDSCAPE LEGEND EXISTING SHADE TREE EVERGREEN TREE DECIDUOUS SHADE TREE MA T C H L I N E : S E E S H E E T 7 0 MATCHLINE: SEE SHEET 71____ MATCHLINE: SEE SHEET 65 1. TURF GRASS SOD. SEE LANDSCAPE DETAILS FOR PLACEMENT AND MIX INFORMATION. 2. SPADE EDGE. SEE LANDSCAPE DETAILS. 3. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. 4. PLANTING AREA TO RECEIVE A MINIMUM OF 12" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. MULCH BED / TREE RING SHRUBS AND ORNAMENTAL GRASSES SOD PERENNIALS RA N G E L I N E R O A D 69 3 GP 10 PD 8 JP15 CK 8 JP80 LB 36 LB 12 PD 89 LB 32 L B 19 L B 14 NW 44 NW 35 LB 36 LB 32 LB 28 LB18 RG224 PK 7 JP A/C A/C A/C A/C MB MON MON MON MON TT PZZZ GM BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 12970 116TH STREET WE S T F I E L D B L V D LANDSCAPE PLANS KEYNOTES LANDSCAPE LEGEND EXISTING SHADE TREE EVERGREEN TREE DECIDUOUS SHADE TREE 1. TURF GRASS SOD. SEE LANDSCAPE DETAILS FOR PLACEMENT AND MIXINFORMATION. 2. SPADE EDGE. SEE LANDSCAPE DETAILS. 3. GRASS SEEDING IN DRIVEABLE GRASS PAVEMENT. SEE HARDSCAPE DETAILS. 4. MEDIAN PLANTING AREA TO RECEIVE A MINIMUM OF 36" OF PLANTING SOIL. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. 5. PLANTING AREA TO RECEIVE A MINIMUM OF 12" OF PLANTING SOIL.SEE SPECIFICATIONS. 6. PLANTING AREA TO RECEIVE A MINIMUM OF 36" OF STRUCTURAL SOIL.SEE HARDSCAPE DETAILS AND SPECIFICATIONS. 7. MANUFACTURER RECOMMENDED GRASS PAVER EDGE RESTRAINT. SEE HARDSCAPE DETAILS AND SPECIFICATIONS. MULCH BED / TREE RING SHRUBS AND ORNAMENTAL GRASSES SOD PERENNIALS RA N G E L I N E R O A D MA T C H L I N E : S E E S H E E T 6 9 M A T C H L I N E : S E E S H E E T 6 5 MAT C H L I N E : S E E S H E E T 6 6 4" 12 " CULTIVATED SOIL UNDISTURBED SOIL NOTE: BREAK THROUGH ANY EXISTING "HARD-PAN" AND REMOVE AS NECESSARY TO PROVIDE GOOD PERCOLATION AND POSITIVE DRAINAGE. 12" U.N.O. SLOPE 3" HARDWOOD MULCH LAYER PERENNIALS (PER PLAN) PLANTING SOIL MIX SPADE EDGE PLANTING PROCEDURE 1. LAYOUT BED AND OUTLINE WITH SPADE EDGE. PLACE SOIL FROM SPADE EDGE WITHIN BED. 2. ROTOTILL BED TO 12" DEPTH. SPREAD 4" MIN. LAYER OF PLANTING SOIL MIX OVER BED. ROTOTILL SOIL MIX INTO TOP OF BED. 3. INSTALL PLANTS, MULCH BEDS, AND WATER THOROUGHLY. DO NOT ALLOW AIR POCKETS TO FORM WHEN BACKFILLING. 4. DO NOT INSTALL PERENNIALS TOO CLOSE TO ADJACENT SHRUB PLANTINGS AND DO NOT PLANT WITHIN SPACING REQUIREMENTS OF THE ADJACENT SHRUBS AS IDENTIFIED IN PLANT SCHEDULE. (I.E. DO NOT PLANT PERENNIALS WITHIN 4' OF ADJACENT SHRUBS SPACED AT 4' O.C.) FINISH GRADE ROW SPACING (SEE GENERAL NOTES) 4" 12 " CULTIVATED SOIL UNDISTURBED SOIL NOTE: BREAK THROUGH ANY EXISTING "HARD-PAN" AND REMOVE AS NECESSARY TO PROVIDE GOOD PERCOLATION AND POSITIVE DRAINAGE. 12" U.N.O. SLOPE 3" HARDWOOD MULCH LAYER PERENNIALS (PER PLAN) PLANTING SOIL MIX SPADE EDGE PLANTING PROCEDURE 1. LAYOUT BED AND OUTLINE WITH SPADE EDGE. PLACE SOIL FROM SPADE EDGE WITHIN BED. 2. ROTOTILL BED TO 12" DEPTH. SPREAD 4" MIN. LAYER OF PLANTING SOIL MIX OVER BED. ROTOTILL SOIL MIX INTO TOP OF BED. 3. INSTALL PLANTS, MULCH BEDS, AND WATER THOROUGHLY. DO NOT ALLOW AIR POCKETS TO FORM WHEN BACKFILLING. 4. DO NOT INSTALL PERENNIALS TOO CLOSE TO ADJACENT SHRUB PLANTINGS AND DO NOT PLANT WITHIN SPACING REQUIREMENTS OF THE ADJACENT SHRUBS AS IDENTIFIED IN PLANT SCHEDULE. (I.E. DO NOT PLANT PERENNIALS WITHIN 4' OF ADJACENT SHRUBS SPACED AT 4' O.C.) FINISH GRADE ROW SPACING (SEE GENERAL NOTES) 4" 12 " CULTIVATED SOIL UNDISTURBED SOIL NOTE: BREAK THROUGH ANY EXISTING "HARD-PAN" AND REMOVE AS NECESSARY TO PROVIDE GOOD PERCOLATION AND POSITIVE DRAINAGE. 12" U.N.O. SLOPE 3" HARDWOOD MULCH LAYER PERENNIALS (PER PLAN) PLANTING SOIL MIX SPADE EDGE PLANTING PROCEDURE 1. LAYOUT BED AND OUTLINE WITH SPADE EDGE. PLACE SOIL FROM SPADE EDGE WITHIN BED. 2. ROTOTILL BED TO 12" DEPTH. SPREAD 4" MIN. LAYER OF PLANTING SOIL MIX OVER BED. ROTOTILL SOIL MIX INTO TOP OF BED. 3. INSTALL PLANTS, MULCH BEDS, AND WATER THOROUGHLY. DO NOT ALLOW AIR POCKETS TO FORM WHEN BACKFILLING. 4. DO NOT INSTALL PERENNIALS TOO CLOSE TO ADJACENT SHRUB PLANTINGS AND DO NOT PLANT WITHIN SPACING REQUIREMENTS OF THE ADJACENT SHRUBS AS IDENTIFIED IN PLANT SCHEDULE. (I.E. DO NOT PLANT PERENNIALS WITHIN 4' OF ADJACENT SHRUBS SPACED AT 4' O.C.) FINISH GRADE ROW SPACING (SEE GENERAL NOTES)TREES QTY BOTANICAL / COMMON NAME CONT CAL SIZE CR 5 Cercidiphyllum japonicum `Rotfuchs` / Red Fox Katsura Tree B & B 2" Cal.As shown GP 4 Ginkgo biloba `Princeton Sentry` / Princeton Sentry Ginkgo B & B 2.5" Cal.As shown PA3 27 Platanus x acerifolia `Exclamation` / London Plane Tree B & B 3"Cal As shown PA6 13 Platanus x acerifolia `Exclamation` / London Plane Tree B & B 6"Cal As shown SHRUBS QTY BOTANICAL / COMMON NAME CONT SIZE SPACING CA 16 Cornus stolonifera `Arctic Fire` / Arctic Fire Dogwood CONT.3 GAL.30" O.C. HL 30 Hydrangea paniculata `Limelight` TM / Limelight Hydrangea CONT.3 GAL.4` O.C. JP 79 Juniperus chinensis `Kallays Compact` / Kallay Compact Pfitzer Juniper CONT.3 GAL.4` O.C. PD 22 Perovskia atriplicifolia Denim `n Lace / Russian Sage CONT.3 GAL.24" O.C. R3 18 Rosa x `Meigalpio` / Red Drift Rose CONT.3 GAL.36" O.C. TD 56 Taxus x media `Densiformis` / Dense Yew CONT.3 GAL.4` O.C. GRASSES QTY BOTANICAL / COMMON NAME CONT SIZE SPACING CK 25 Calamagrostis x acutiflora `Karl Foerster` / Feather Reed Grass CONT.1 Gal.30" O.C. PS 62 Panicum virgatum `Shenandoah` / Switch Grass CONT.1 Gal.36" O.C. PK 84 Pennisetum orientale `Karley Rose` / Karley Rose Fountain Grass CONT.1 Gal.36" O.C. GROUND COVERS QTY BOTANICAL / COMMON NAME CONT SIZE SPACING LB 1,123 Liriope muscari `Big Blue` / Big Blue Lilyturf Cont.4" Pot 18" O.C. PERENNIALS QTY BOTANICAL / COMMON NAME CONT SIZE SPACING HH 104 Hemerocallis x `Happy Returns` / Happy Returns Daylily Cont.1 Gal.24" OC NW 194 Nepeta x faassenii `Walkers Low` / Walkers Low Catmint Cont.1 Gal.24" OC RG2 84 Rudbeckia fulgida sullivantii `Goldsturm` / Black-eyed Susan Cont.1 Gal.24" OC PLANT SCHEDULE BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK LANDSCAPE ARCHITECT DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 05/07/21RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER$P E N T B L S $ $P L T D R V S $ CITY OF CARMEL AEB 1"=20' AEB AEBAEB 16-ENG-70 129LANDSCAPE DETAILS 71 1. CONTRACTOR TO VERIFY ALL UTILITY LOCATIONS IN THE FIELD PRIOR TO BEGINNING WORK. CONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO UTILITIES ASSOCIATED WITH WORK. UTILITIES SHALL BE REPAIRED TO SATISFACTION OF THE UTILITY OWNER AND/OR OPERATING AUTHORITY AT NO ADDITIONAL COST. 2. SEE HARDSCAPE SHEETS FOR LIMITS OF PLANTING SOIL AND APPROPRIATE DEPTHS WITHIN MEDIANS. ALL OTHER PLANTING BEDS TO RECEIVE A MINIMUM OF 12" OF PLANTING SOIL PLANTING SOIL MIX TO CONSIST OF (23 TOPSOIL, 13 MULCH AND SOIL CONDITIONER) SHALL BE PLACED ON ALL AREAS TO BE SEEDED, SODDED AND PLANTED. PLANTING SOIL MIX SHALL BE FREE FROM SUBSOIL, VEGETATION, WEEDS OR ANY EXTRANEOUS OR DELETERIOUS MATERIALS LARGER THAN 1". REMOVE ANY UNSUITABLE AND EXCESS TOPSOIL, AS DETERMINED BY SOILS ENGINEER, FROM THE SITE. FURNISH ANY ADDITIONAL TOPSOIL NEEDED AT NO ADDITIONAL COST. ADDED TOPSOIL SHALL BE INCORPORATED INTO EXISTING SOIL. 3. IN CASE OF DISCREPANCIES BETWEEN THE PLAN AND THE PLANT LIST, THE PLAN SHALL DICTATE. IF IN QUESTION, CONTACT THE LANDSCAPE ARCHITECT. 4. ALL PLANTING BEDS SHALL HAVE A 3" THICK LAYER OF SHREDDED HARDWOOD BARK MULCH. NO UTILITY MULCH OR PROCESSED TREE TRIMMINGS WILL BE ALLOWED. ALL PLANTING BEDS SHALL HAVE PRE-EMERGENT HERBICIDE APPLIED AS PER MANUFACTURER'S RECOMMENDATION, AFTER INSTALLATION IS COMPLETE. 5. FINAL PLACEMENT OF PLANT MATERIALS, ETC. SHALL BE APPROVED BY LANDSCAPE ARCHITECT BEFORE PLANTING OPERATIONS ARE TO PROCEED. ALL TREE LOCATIONS SHALL BE MARKED WITH A WOODEN STAKE INDICATING VARIETY AND SIZE OF TREE. 6. NO SUBSTITUTIONS OF PLANT MATERIAL WILL BE ALLOWED. IF PLANTS ARE SHOWN TO BE UNAVAILABLE, THE CONTRACTOR SHALL NOTIFY LANDSCAPE ARCHITECT PRIOR TO BID DATE IN WRITING. ALL PLANTS SHALL BE INSPECTED AND TAGGED WITH PROJECT IDENTIFICATION AT NURSERY OR CONTRACTOR'S OPERATION PRIOR TO MOVING TO JOB SITE. PLANTS MAY ALSO BE INSPECTED AND APPROVED OR REJECTED ON THE JOB SITE. 7. ALL PLANTS ARE TO MEET OR EXCEED AMERICAN STANDARDS FOR NURSERY STOCK, 2004 EDITION, AS SET FORTH BY AMERICAN ASSOCIATION OF NURSERYMEN. 8. PLANTS AND ALL OTHER MATERIALS TO BE STORED ON SITE WILL BE PLACED WHERE THEY WILL NOT CONFLICT WITH CONSTRUCTION AND AS DIRECTED BY OWNER. 9. ALL NEW LANDSCAPE PLANTINGS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FOLLOWING FINAL INSPECTION BY LANDSCAPE ARCHITECT. AT END OF THIS PERIOD, PLANT MATERIAL TERMED DEAD OR UNSATISFACTORY BY LANDSCAPE ARCHITECT SHALL BE REPLACED AT NO ADDITIONAL CHARGE BY THE LANDSCAPE CONTRACTOR. 10. ALL DISTURBED LAWN AREAS SHALL BE HYDRO-SEEDED OR SODDED AS SHOWN PER THE LANDSCAPE AND EROSION CONTROL PLANS. 11. LAWN AND SOD AREAS ARE TO BE GRADED UNIFORMLY WITHOUT ANY UNDULATIONS OR IRREGULARITIES IN THE SURFACE PRIOR TO ANY HYDRO-SEED OR SOD WORK. 12. ALL LAWN IS TO BE A BLEND PER THE PLANT SCHEDULE. HYDRO-SEED AREAS ARE TO HAVE 0% NOXIOUS WEED AND FREE OF DISEASE. 13. PROTECT LAWN SEEDED AREAS WITH STRAW MULCH. SPREAD MULCH UNIFORMLY AT A MINIMUM RATE OF 2 TONS PER ACRE TO FORM A CONTINUOUS BLANKET 1 12 INCHES IN LOOSE THICKNESS OVER SEEDED AREAS. GENERAL NOTES: 1 TREE PLANTING DETAIL3SHRUB PLANTING DETAIL 2 PERENNIAL/ GROUND COVER PLANTING DETAIL W V FF E M B W V FF E W V W V 1" 1" 1" 1" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 2"SLV 3"SLV 3"SLV2"SLV 3"SLV2"SLV 3"SLV2"SLV 2"SLV 2"SLV2"SLV 3"SLV2"SLV 2"SLV2"SLV M B W V W V W V 1" 1" 1" 1" 1.5" 1.5" 1.5" 1.5" 2"SLV 3"SLV 3"SLV2"SLV 3"SLV2"SLV 3"SLV2"SLV 2"SLV 2"SLV2"SLV 66 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 07/31/17RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER $P E N T B L S $ $P L T D R V S $ CITY OF CARMEL 16-ENG-37 CEC CEC CEC CEC 1"=20' 125IRRIGATION PLANS LINE "PR-RL1" WESTFIELD BLVD LEGEND DESCRIPTION APPROVED MANUFACTURERS Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-PC**Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-FC** Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-EST/SST** Remote Control Valves Rain Bird 100 PGA Series Controllers (3) Rain Sensors (3) Backflow Preventers Meters (3)Size as needed Rain Bird 5RCQuick Couple Valve 1" 200 PSI SDR 21 PVC Lateral Pipe 1.25" 160 PSI SDR 26 PVC Lateral Pipe 1.5" 200 PSI SDR 21 PVC Mainline Pipe M CR (317) 585-0167www.irrigationdesignsource.com 116 SHADOWLAWN DRIVEFISHERS, IN 46038 ???GPM # OF ZONE VALVE SIZE ** Multi-Stream Rotors (12'-28') provide appropriate nozzle selection and adjustment to provide 100% coverage asthey exist on site. Hunter PROS-04-PRS40-CV Rotator-PC**Hunter PROS-04-PRS40-CV Rotator-FC** Hunter PROS-04-PRS40-CV Rotator LCS/RCS/SS** Hunter ICV 101G Series Hunter WSS-SEN Hunter HQ-5RC Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45 Rotator-PC** Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45Rotator-EST/SST** Weathermatic SL1600 Flow Bundle w/ modules, weather sensor, Smartlink aircard & service Weathermatic Wireless Hunter PROS-12-PRS40-CV Rotator PC** Hunter PROS-12-PRS40-CVRotator LCS/RCS/SS** Rain Bird 1812-SAM P45 Rotator-FC**Multi-Stream Shrub Rotor Hunter PROS-12-PRS40-CV Rotator FC** w/ Enclosures (3) Wilkins 975XL 1" RPZStrong Box SBBC-30AL Master Valves (3)Rain Bird PEB-PRS-Dial Flow Sensor Tees (3) 1'' Weathermatic Flow Sensor TeeF MA T C H L I N E : S H E E T 6 7 13778 LANDSCAPE ARCHITECT DATE 04/12/19 72 W V W V W V W V P.O.C. #1 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1"1" 1.25" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 3"SLV2"SLV 3"SLV2"SLV 3"SLV2"SLV 2"SLV 2"SLV2"SLV 3"SLV2"SLV 3"SLV2"SLV 2"SLV 2"SLV 3"SLV2"SLV 3"SLV 3"SLV 2"SLV3"SLV 2"SLV2"SLV 2"SLV3"SLV 2"SLV2"SLV 3"SLV 3"SLV2"SLV 2"SLV 3"SLV2"SLV 3"SLV2"SLV 2"SLV 2"SLV 2"SLV 2"SLV 2"SLV M C R F ADDITIONAL VALVE BOX WITH 3 ADDITIONAL WIRE W V W V 1" 1" 1" 1" 1"1" 1.25" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 3"SLV 3"SLV2"SLV 2"SLV 3"SLV2"SLV 3"SLV2"SLV 2"SLV 2"SLV 2"SLV 2"SLV 2"SLV C R F 67 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 07/31/17RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER $P E N T B L S $ $P L T D R V S $ CITY OF CARMEL 16-ENG-37 CEC CEC CEC CEC 1"=20' 125 RANGE LINE ROAD 11 6 T H S T R E E T MA T C H L I N E : S H E E T 6 8 IRRIGATION PLANS LINE "PR-RL1" LEGEND DESCRIPTION APPROVED MANUFACTURERS Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-PC** Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-FC** Multi-Stream Turf Rotor Rain Bird 1804-SAM P45Rotator-EST/SST** Remote Control Valves Rain Bird 100 PGA Series Controllers (3) Rain Sensors (3)Backflow Preventers Meters (3)Size as needed Rain Bird 5RCQuick Couple Valve 1" 200 PSI SDR 21 PVC Lateral Pipe 1.25" 160 PSI SDR 26 PVC Lateral Pipe 1.5" 200 PSI SDR 21 PVC Mainline Pipe M CR (317) 585-0167www.irrigationdesignsource.com 116 SHADOWLAWN DRIVEFISHERS, IN 46038 ???GPM # OF ZONE VALVE SIZE ** Multi-Stream Rotors (12'-28') provide appropriate nozzle selection and adjustment to provide 100% coverage as they exist on site. Hunter PROS-04-PRS40-CV Rotator-PC** Hunter PROS-04-PRS40-CV Rotator-FC** Hunter PROS-04-PRS40-CVRotator LCS/RCS/SS** Hunter ICV 101G Series Hunter WSS-SEN Hunter HQ-5RC Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45 Rotator-PC** Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45 Rotator-EST/SST** Weathermatic SL1600 Flow Bundle w/ modules, weather sensor, Smartlink aircard & service Weathermatic Wireless Hunter PROS-12-PRS40-CV Rotator PC** Hunter PROS-12-PRS40-CV Rotator LCS/RCS/SS** Rain Bird 1812-SAM P45 Rotator-FC**Multi-Stream Shrub Rotor Hunter PROS-12-PRS40-CV Rotator FC** w/ Enclosures (3) Wilkins 975XL 1" RPZ Strong Box SBBC-30AL Master Valves (3)Rain Bird PEB-PRS-Dial Flow Sensor Tees (3) 1'' Weathermatic Flow Sensor TeeF MA T C H L I N E : S H E E T 6 6 13779 LANDSCAPE ARCHITECT DATE 04/12/19 73 W V W V W V W V W V W V W V 836.0848344BRK P.O.C. #2 1" 1" 1" 1" 1" 1" 1" 1" 1.25" 1"1" 1.5" 1.5" 1.5" 1.5"1.5"1.5"1.5" 1.5" 1.5" 1.5" 1.5"1.5" 1.5" 1.5" 1.5" 1.5" 1.5" 3"SLV2"SLV 3"SLV2"SLV 3"SLV 3"SLV2"SLV2"SLV2"SLV3"SLV 2"SLV 2"SLV 2"SLV 2"SLV 2"SLV3"SLV 2"SLV 2"SLV2"SLV 2"SLV3''SLV 3"SLV 3"SLV2"SLV 3"SLV 3"SLV 3"SLV2"SLV 2"SLV3"SLV 2"SLV 2"SLV 2"SLV 2"SLV MC R F ADDITIONAL VALVE BOX WITH 3 ADDITIONAL WIRE 68 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 07/31/17RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER $P E N T B L S $ $P L T D R V S $ CITY OF CARMEL 16-ENG-37 CEC CEC CEC CEC 1"=20' 125 RANGE LINE ROAD ME D I C A L D R I V E MA T C H L I N E : S H E E T 6 9 MA T C H L I N E : S H E E T 6 7 IRRIGATION PLANS LINE "PR-RL1" LEGEND DESCRIPTION APPROVED MANUFACTURERS Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-PC** Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-FC**Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-EST/SST** Remote Control Valves Rain Bird 100 PGA Series Controllers (3)Rain Sensors (3) Backflow Preventers Meters (3)Size as needed Rain Bird 5RCQuick Couple Valve 1" 200 PSI SDR 21 PVC Lateral Pipe 1.25" 160 PSI SDR 26 PVC Lateral Pipe 1.5" 200 PSI SDR 21 PVC Mainline Pipe M C R (317) 585-0167www.irrigationdesignsource.com 116 SHADOWLAWN DRIVEFISHERS, IN 46038 ???GPM # OF ZONE VALVE SIZE ** Multi-Stream Rotors (12'-28') provide appropriate nozzle selection and adjustment to provide 100% coverage asthey exist on site. Hunter PROS-04-PRS40-CV Rotator-PC** Hunter PROS-04-PRS40-CV Rotator-FC** Hunter PROS-04-PRS40-CVRotator LCS/RCS/SS** Hunter ICV 101G Series Hunter WSS-SEN Hunter HQ-5RC Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45 Rotator-PC** Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45Rotator-EST/SST** Weathermatic SL1600 Flow Bundle w/ modules, weather sensor, Smartlink aircard & serviceWeathermatic Wireless Hunter PROS-12-PRS40-CV Rotator PC** Hunter PROS-12-PRS40-CVRotator LCS/RCS/SS** Rain Bird 1812-SAM P45 Rotator-FC**Multi-Stream Shrub Rotor Hunter PROS-12-PRS40-CV Rotator FC** w/ Enclosures (3) Wilkins 975XL 1" RPZStrong Box SBBC-30AL Master Valves (3)Rain Bird PEB-PRS-DialFlow Sensor Tees (3) 1'' Weathermatic Flow Sensor TeeF 13780 LANDSCAPE ARCHITECT DATE 04/12/19 74 W V F P P.O.C. #3 1" 1"1" 1" 1" 1.5" 1.5" 1.5"1.5"1.5" 1.5" 1.5" 2"SLV 2"SLV 2"SLV 2"SLV 2"SLV 2"SLV 3"SLV 2"SLV 2"SLV2"SLV 3"SLV2"SLV 3"SLV 3"SLV2"SLV 3"SLV M F BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 07/31/17RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER $P E N T B L S $ $P L T D R V S $ CITY OF CARMEL 16-ENG-37 CEC CEC CEC CEC 1"=20' 125 RANGE LINE ROAD MA T C H L I N E : S H E E T 6 8 MA T C H L I N E : S H E E T 7 0 IRRIGATION PLANS LINE "PR-RL1" 69 LEGEND DESCRIPTION APPROVED MANUFACTURERS Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-PC**Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-FC** Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-EST/SST** Remote Control Valves Rain Bird 100 PGA Series Controllers (3) Rain Sensors (3) Backflow Preventers Meters (3)Size as needed Rain Bird 5RCQuick Couple Valve 1" 200 PSI SDR 21 PVC Lateral Pipe 1.25" 160 PSI SDR 26 PVC Lateral Pipe 1.5" 200 PSI SDR 21 PVC Mainline Pipe M CR (317) 585-0167www.irrigationdesignsource.com 116 SHADOWLAWN DRIVEFISHERS, IN 46038 ???GPM # OF ZONE VALVE SIZE ** Multi-Stream Rotors (12'-28') provide appropriate nozzle selection and adjustment to provide 100% coverage asthey exist on site. Hunter PROS-04-PRS40-CV Rotator-PC**Hunter PROS-04-PRS40-CV Rotator-FC** Hunter PROS-04-PRS40-CV Rotator LCS/RCS/SS** Hunter ICV 101G Series Hunter WSS-SEN Hunter HQ-5RC Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45 Rotator-PC** Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45Rotator-EST/SST** Weathermatic SL1600 Flow Bundle w/ modules, weather sensor, Smartlink aircard & service Weathermatic Wireless Hunter PROS-12-PRS40-CV Rotator PC** Hunter PROS-12-PRS40-CVRotator LCS/RCS/SS** Rain Bird 1812-SAM P45 Rotator-FC**Multi-Stream Shrub Rotor Hunter PROS-12-PRS40-CV Rotator FC** w/ Enclosures (3) Wilkins 975XL 1" RPZStrong Box SBBC-30AL Master Valves (3)Rain Bird PEB-PRS-Dial Flow Sensor Tees (3) 1'' Weathermatic Flow Sensor TeeF 13781 LANDSCAPE ARCHITECT DATE 04/12/19 75 MB WV WV WV WV FFE WV WV FFE FFE P. O . C . # 1 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1. 2 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 3" S L V 3" S L V 2" S L V 3" S L V 2" S L V 3" S L V 2" S L V 2" S L V 2" S L V 2" S L V 3" S L V 2" S L V 2" S L V 2" S L V 3" S L V 3" S L V 2" S L V 3" S L V 2" S L V 2" S L V 2" S L V 2" S L V 3" S L V 2" S L V 2" S L V 3" S L V 3" S L V 2" S L V 2" S L V 3" S L V 2" S L V 3" S L V 2" S L V 2" S L V 2" S L V 2" S L V M C R F AD D I T I O N A L V A L V E BO X W I T H 3 AD D I T I O N A L W I R E WV WV WV 1" 1" 1"1" 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 3" S L V 2" S L V 3" S L V 2" S L V 2" S L V 2" S L V 2" S L V 3" S L V 2" S L V 2" S L V 3" S L V C R AD D I T I O N A L V A L V E BO X W I T H 3 AD D I T I O N A L W I R E 71 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 07/31/17RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER $P E N T B L S $ $P L T D R V S $ CITY OF CARMEL 16-ENG-37 CEC CEC CEC CEC 1"=20' 125 116TH STREET RA N G E L I N E R O A D MA T C H L I N E : 7 2 MATCHLINE: SHEET 67 MATCHLINE: SHEET 66 IRRIGATION PLANS LINE "PR-RL1" LEGEND DESCRIPTION APPROVED MANUFACTURERSMulti-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-PC** Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-FC** Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-EST/SST** Remote Control Valves Rain Bird 100 PGA Series Controllers (3) Rain Sensors (3) Backflow Preventers Meters (3)Size as neededRain Bird 5RCQuick Couple Valve 1" 200 PSI SDR 21 PVC Lateral Pipe 1.25" 160 PSI SDR 26 PVC Lateral Pipe 1.5" 200 PSI SDR 21 PVC Mainline Pipe M CR (317) 585-0167www.irrigationdesignsource.com 116 SHADOWLAWN DRIVEFISHERS, IN 46038 ???GPM # OF ZONE VALVE SIZE ** Multi-Stream Rotors (12'-28') provide appropriate nozzle selection and adjustment to provide 100% coverage asthey exist on site. Hunter PROS-04-PRS40-CV Rotator-PC** Hunter PROS-04-PRS40-CV Rotator-FC** Hunter PROS-04-PRS40-CV Rotator LCS/RCS/SS** Hunter ICV 101G Series Hunter WSS-SEN Hunter HQ-5RC Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45 Rotator-PC** Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45Rotator-EST/SST** Weathermatic SL1600 Flow Bundle w/ modules, weather sensor, Smartlink aircard & service Weathermatic Wireless Hunter PROS-12-PRS40-CV Rotator PC** Hunter PROS-12-PRS40-CVRotator LCS/RCS/SS** Rain Bird 1812-SAM P45 Rotator-FC**Multi-Stream Shrub Rotor Hunter PROS-12-PRS40-CV Rotator FC** w/ Enclosures (3) Wilkins 975XL 1" RPZStrong Box SBBC-30AL Master Valves (3)Rain Bird PEB-PRS-Dial Flow Sensor Tees (3) 1'' Weathermatic Flow Sensor TeeF 13783 LANDSCAPE ARCHITECT DATE 04/12/19 77 MB WV WV WV WV WV P. O . C . # 1 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1" 1. 2 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 1. 5 " 3" S L V 3" S L V 2" S L V 3" S L V 2" S L V 3" S L V 2" S L V 2" S L V 2" S L V 2" S L V 3" S L V 2" S L V 3" S L V 2" S L V 2" S L V 2" S L V 3" S L V 2" S L V 3" S L V 3" S L V 2" S L V 3" S L V 2" S L V 3" S L V 2" S L V 3" S L V 3" S L V 2" S L V 2" S L V 3" S L V 2" S L V 3" S L V 2" S L V 2" S L V 2" S L V 2" S L V M C R F AD D I T I O N A L V A L V E BO X W I T H 3 AD D I T I O N A L W I R E BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 07/31/17RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER $P E N T B L S $ $P L T D R V S $ CITY OF CARMEL 16-ENG-37 CEC CEC CEC CEC 1"=20' 125 116TH STREET RA N G E L I N E R O A D IRRIGATION PLANS LINE "PR-RL1" LEGEND DESCRIPTION APPROVED MANUFACTURERS Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-PC** Multi-Stream Turf Rotor Rain Bird 1804-SAM P45 Rotator-FC** Multi-Stream Turf Rotor Rain Bird 1804-SAM P45Rotator-EST/SST** Remote Control Valves Rain Bird 100 PGA Series Controllers (3) Rain Sensors (3)Backflow Preventers Meters (3)Size as needed Rain Bird 5RCQuick Couple Valve 1" 200 PSI SDR 21 PVC Lateral Pipe 1.25" 160 PSI SDR 26 PVC Lateral Pipe 1.5" 200 PSI SDR 21 PVC Mainline Pipe M C R (317) 585-0167www.irrigationdesignsource.com 116 SHADOWLAWN DRIVEFISHERS, IN 46038 ???GPM # OF ZONE VALVE SIZE ** Multi-Stream Rotors (12'-28') provide appropriate nozzle selection and adjustment to provide 100% coverage as they exist on site. Hunter PROS-04-PRS40-CV Rotator-PC** Hunter PROS-04-PRS40-CV Rotator-FC** Hunter PROS-04-PRS40-CVRotator LCS/RCS/SS** Hunter ICV 101G Series Hunter WSS-SEN Hunter HQ-5RC Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45 Rotator-PC** Multi-Stream Shrub Rotor Rain Bird 1812-SAM P45 Rotator-EST/SST** Weathermatic SL1600 Flow Bundle w/ modules, weather sensor, Smartlink aircard & serviceWeathermatic Wireless Hunter PROS-12-PRS40-CV Rotator PC** Hunter PROS-12-PRS40-CV Rotator LCS/RCS/SS** Rain Bird 1812-SAM P45 Rotator-FC**Multi-Stream Shrub Rotor Hunter PROS-12-PRS40-CV Rotator FC** w/ Enclosures (3) Wilkins 975XL 1" RPZ Strong Box SBBC-30AL Master Valves (3)Rain Bird PEB-PRS-Dial Flow Sensor Tees (3) 1'' Weathermatic Flow Sensor TeeF 72 MA T C H L I N E : S H E E T 7 1 MATCHLINE: SHEET 67 MATCHLINE: SHEET 66 13784 LANDSCAPE ARCHITECT DATE 04/12/19 78 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS N/A 07/31/17RECOMMENDEDFOR APPROVAL $FILEA$$DATE$$TIME$$USER $P E N T B L S $ $P L T D R V S $ CITY OF CARMEL 16-ENG-37 CEC CEC CEC CEC 1"=20' 125IRRIGATION DETAILS GENERAL IRRIGATION NOTES: 1. This irrigation design is diagrammatic. Actual layout of piping, sprinkler heads, valves, controllers and related equipment shall be determined on site. Minor field adjustments shall be made at no additional cost to the Owner. 2. It is the responsibility of the irrigation contractor to be familiar with all grades difference, locations of walls, structures and utilities and make the necessary adjustments to accommodate the irrigation system as designed. Do not willfully install the irrigation system as shown on the drawings when it is obvious in the field that unknown obstructions, grades or dimensions exist that might not have been considered in the engineering. Such obstructions or differences should be brought to the attention of the Owner's authorized representative. In the event that this notification is not performed, the irrigation contractor shall assume full responsibility for any revisions and cost necessary. 3. The irrigation system design is based on running irrigation zones at a minimum operating pressure of 65psi @ the point of connection (p.o.c.) and a maximum flow demand of 17gpm. The irrigation contractor shall verify water pressures prior to construction. Report differences between requirements and actual readings to the Owner's authorized representative. A booster pump may be necessary if the required pressure is not available. Additional costs shall be submitted to the Owner as a change order. The point of connection location is approximate. Verify exact location in the field with the Owner's representative. The flow demand for individual mainlines shall not exceed the following guidelines. 1.5" Class 200=29-35gpm 4. The Owner shall provide 120V-AC power source at the controller location. The irrigation contractor shall make the final connection from the electrical source to the controller. 5. A Rain Sensor shall be installed in the vicinity of the controller. Coordinate mounting location with the Owner. 6. Install all backflow prevention devices and all piping between the point of connection and the backflow preventer as per local codes. 7. Final location of the backflow preventer and the automatic controller shall be approved by the Owner's representative per local codes. 8. A quick coupling valve shall be located at the irrigation water supply point of connection to provide for a point of injection of compressed air to purge the system of retained water for winterization. 9. Pipe size shall conform to those shown on drawings. No substitutions of smaller pipe sizes shall be permitted, but substitutions for larger sizes may be approved. Minimum pipe shall be 1". 10.All pipe and communication wire under hard surfaces shall be placed in separate sleeving. All wire shall run, whenever possible with the mainline. 11.All lateral zones shall be connected to the mainline with PVC pipe and sized as follows: 1" Class 200=0-17gpm 1.25" Class 160=18-28gpm 12.All sprinkler heads shall be set perpendicular and flush to finish grade and with a clearance of 2" (min.) from the edge of any hardscape unless otherwise specified. 13.All sprinkler heads and valves shall be flushed and adjusted for optimum coverage with minimum over spray on hardscapes or buildings. 14.All irrigation equipment not otherwise detailed or specified shall be installed as per manufacturer's recommendations and specifications. 15.Refer to the specifications for additional detailed information. 73 N O R T H MULTI-STREAM TURF ROTOR PVC STREET ELL ORMALE BARBED ELBOW LATERAL LINE WITHPVC TEE OR ELL PVC STREET ELL ORMALE BARBED ELBOW PVC FLEX HOSE OR SWING PIPE SPRINKLER HEAD FINISH GRADE ROTARY NOZZLE FINISH GRADE MAINLINE PVC OR GALVANIZEDELL NOTE:INSTALL PERMANUFACTURER'S RECOMMENDATIONS INSULATE ASREQUIRED BRASS OR GALVANIZEDNIPPLES (AS REQUIRED) GALVANIZED BRASSUNION (AS REQUIRED) GALVANIZED ELL GALVANIZED ELL REDUCE PRESSUREASSEMBLY 12"MINIMUM 18"MINIMUM BACKFLOW PREVENTER-RP REMOTE CONTROL VALVE SNAP-TITE WIRECONNECTORS ANDEXPANSION COILS, 10WRAPS AROUND 1/2" PIPE DURABLE WEATHERRESISTANT PLASTIC VALVEWITH EXTENSIONS IFNECESSARY INSTALL VALVE BOX 1/2"ABOVE FINISH GRADE INTURF AND 2" IN SHRUBAREAS FINISH GRADE REMOTE CONTROL VALVESIZE PER SPECIFICATIONGLOBE/ANGLE CONFIG. PVC ELL 4" PEA GRAVEL BASE MAINLINE WITH PVC TEE OR ELL VALVE WIRE FROM CONTROLLER COMMON WIRE FROMCONTROLLER TO ELECTRICCONTROL VALVE AND ON TONEXT VALVE QUICK COUPLER VALVE 10" DURABLE WEATHERRESISTANT PLASTIC VALVEBOX WITH EXTENSIONS IFNECESSARY QUICK COUPLER VALVE INSTALL VALVE BOX 1/2" ABOVE FINISH GRADE IN TURF AND 2" IN SHRUBAREAS FINISH GRADE 1" PVC CLASS 200 SDR21PIPE 24" IN LENGTH 4" PEA GRAVEL BASE LASCO SNAP-LOK SWINGJOINT WITH MALE BRASSSTABILIZER ELBOW MAINLINE WITH PVC TEEOR ELL 3/8" REBAR IN STABILIZINGLUGS WR2WIRELESS SENSOR WIRELESS RAIN SENSOR CABLE HARNESS FOR CONTROLLERINTERFACE (30" MAXIMUM) SENSOR & BRACKETRAIN BIRD WR2 WIRELESSSENSOR CONTROLLER INTERFACE DRIPLINE TYPICAL LAYOUT MANUAL LINEFLUSHING VALVEPLUMBED TO PVC IN 6"VALVE BOX DRIPLINE STARTCONNECTION MALEADAPTER PVC HEADER PVC HEADER DRIPLINE STARTCONNECTION REMOTE CONTROLVALVE KIT IN VALVEBOX AREA PERIMETER DRIPLINE TUBING PERIMETER LATERALS2" TO 4" FROM EDGE 18" 18" F 3" MIN. ON OFF FINISH GRADE PVC SCH 40 ELL PVC SCH 80 NIPPLE (LENGTH AS REQUIRED, 1 OF 2) 30-INCH LINEAR LENGTH OFWIRE, COILED WATERPROOF CONNECTION ID TAG VALVE BOX WITH COVER PVC SCH 40 F ADAPTER LATERAL PIPE BRICK (1 OF 4) 3-INCH MINIMUM DEPTHOF 3/4-INCH WASHEDGRAVEL CONTROL ZONE KIT: RAIN BIRD XCZ-075-PRF ORRAIN BIRD XCZ-LF-100-PRF OR RAINBIRD XCZ-100-PRF AS REQUIRED BYGPM (INCLUDES VALVE ANDPRESSURE REG. FILTER PVC SCH 80 NIPPLE(2-INCH LENGTH,HIDDEN AND PVCSCH 40 ELL PVC SCH 40 TEE OR ELL PVC MAINLINE DRIP REMOTE CONTROL VALVE 13785 LANDSCAPE ARCHITECT DATE 04/12/19 79 1 0 5 1 1 0 1 1 5 1 1 0 104+00.00 "PR-RL1" BEGIN PROJECT Westfield Blvd. Line "PR-S1A" 1 1 6 t h S t. 3 5 + 0 0 Range Line Rd. Line "PR-RL1" Range Line Rd. Line "PR-RL1" Me d ic a l D r. P.O.T. 12+32.76 "PR-S2A" P.O.T. 114+61.91 "PR-RL2"= Line "PR-S2A" P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = 43 43 48 48 48 48 43 43 45 45 49 49 49 49 43 43 43 48 48 45 45 4854 54 53 47 47 47 47 47 47 47 47 ONEWAY YIELD YIELD YIELD YIELD MPH 15 116th St MPH 15 116th St YIELD YIELD Medical Dr MPH 15 YIELD YIELD MPH 15 Medical Dr 1 2 ' 12 ' 1 2 ' 1 2 ' 14'14' 14' 14' 14' 14' 14 ' 14 ' 1 0 ' 1 0 ' 1 0 ' 1 0 ' 1 0 ' 1 0 ' 1 0 ' 1 0 ' 1 0 ' 1 0 ' 1 0 ' 1 0 ' 15 ' 1 5 ' 15 ' 15 ' Pavement Marker, Blue Snowplowable Raised Pavement Marker, Blue Snowplowable Raised R4-7 (24" X 30") 105+93 W16-7P (24" X 12") W11-2 (30" X 30") 106+82 D1-1d (48" X 10") 107+02 R1-2 (36" X 36" X 36") 108+56 R1-2 (36" X 36" X 36") W16-7P (24" X 12") W11-2 (30" X 30") 109+07 R3-8 (30" X 30") 110+05 108+60 W16-7P (24" X 12") W11-2 (30" X 30") 108+81 D1-1d (48" X 10") 108+59 R1-2 (36" X 36" X 36") 107+04 R1-2 (36" X 36" X 36") 107+01 W16-7P (24" X 12") W11-2 (30" X 30") 106+53 R3-8 (30" X 30") 105+56 W13-1P (18" X 18) W16-8P (24" X 8") W2-6 (30" X 30") 104+56 W13-1P (18" X 18) W16-8P (24" X 8") W2-6 (30" X 30") 111+37 W16-7P (24" X 12") W11-2 (30" X 30") 113+89 R1-2 (36" X 36" X 36") 115+16 R1-2 (36" X 36" X 36") 115+13 W16-7P (24" X 12") W11-2 (30" X 30") 115+51 R3-8 (30" X 30") 116+51 W13-1P (18" X 18) W16-8P (30" X 8") W2-6 (30" X 30") 117+51 W16-7P (24" X 12") W11-2 (30" X 30") 115+28 R1-2 (36" X 36" X 36") 114+12 R1-2 (36" X 36" X 36") 114+08 W16-7P (24" X 12") W11-2 (30" X 30") 113+77 R3-8 (30" X 30") 112+82 W13-1P (18" X 18) W16-8P (30" X 8") W2-6 (30" X 30") 111+77 20.00' LT. +11.79 17.15' RT. +97.31 17.88' LT. +19.81 14.00' LT. +07.03 14.00' RT. +07.03 20.00' LT. +71.38 19.99' RT. +70.64 48 Pavement Marker, Blue Snowplowable Raised 56 56 56 56 Piano Key Cross Walk Lines Shall be Placed with Gaps in Vehicle Natural Wheel Path For Additional Details, see Roundabout Pavement Markings and Sign Details. All Stationing from Line "PR-RL1" Unless Otherwise Noted. NOTES: 100'-0" 152'-0" 20'-0" 20'-0" 48 STD. DWG. 10-38 4-RPM (Yellow) See Carmel 39 39 39 W4-2(R) (36" X 36") 105+75 38 WestfieldBlvd Range Line Rd LEGEND 41 Line, Thermoplastic, Dotted, White, 8 in. (2' Line, 2' Gap) 46 47 44 Line, Thermoplastic, Solid, White, 4 in. Line, Thermoplastic, Solid, Yellow, 4 in. 42 "Sharks Teeth", Yield Line, White, See Carmel Standard Drawing 10-25B 40 45 48 Line, Thermoplastic, Solid, White, 6 in. 49 43 54 Line, Thermoplastic, Solid, Yellow, 8" Pavement Message Marking, Thermoplastic, Lane Indication Arrow, White Pavement Message Marking, Thermoplastic, Lane Indication Arrow, "Fishhook", White Transverse Marking, Thermoplastic, Crosswalk Line, White, 6"50 Transverse Marking, Thermoplastic, Crosshatch Line, Yellow, 12"53 Transverse Marking, Multi-Component, Pedestrian Crossing Line, Thermoplastic, Dotted, White, 4 in (3' Line, 9' Gap) 56 Line, Thermoplastic, Dotted, White, 6 in. (2' Line, 4' Gap) 57 Transverse Marking, Thermoplastic, Crosswalk Line, White, 24 in. Line, Multi-Component, Broken, White, 6 in. (2' Line, 4' Gap) 39 Exist. Sign to Remain in Place Pavement Message Marking, Thermoplastic, Only58 38 Sign, Sheet, Relocate 1"=30' N/A RJC NRMNRM TJM PAVEMENT MARKINGS AND SIGN DETAILS - LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 79 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PM.01.dgn5/24/2021 10:28:55 AMtmckinney Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 1 2 5 Range Line Rd.Line "PR-RL1" C a r m e l D r . 122+12.93 "PR-RL1" INCIDENTAL CONSTRUCTION END PROJECT & BEGIN 47 47 43 43 1 0 ' 1 0 ' 1 0 ' 1 0 ' All Stationing from Line "PR-RL1" Unless Otherwise Noted. NOTE: 39 39 39 124+63.91 "PR-RL1" END INCIDENTAL CONSTRUCTION LEGEND 41 Line, Thermoplastic, Dotted, White, 8 in. (2' Line, 2' Gap) 46 47 44 Line, Thermoplastic, Solid, White, 4 in. Line, Thermoplastic, Solid, Yellow, 4 in. 42 "Sharks Teeth", Yield Line, White, See Carmel Standard Drawing 10-25B 40 45 48 Line, Thermoplastic, Solid, White, 6 in. 49 43 54 Line, Thermoplastic, Solid, Yellow, 8" Pavement Message Marking, Thermoplastic, Lane Indication Arrow, White Pavement Message Marking, Thermoplastic, Lane Indication Arrow, "Fishhook", White Transverse Marking, Thermoplastic, Crosswalk Line, White, 6"50 Transverse Marking, Thermoplastic, Crosshatch Line, Yellow, 12"53 Transverse Marking, Multi-Component, Pedestrian Crossing Line, Thermoplastic, Dotted, White, 4 in (3' Line, 9' Gap) 56 Line, Thermoplastic, Dotted, White, 6 in. (2' Line, 4' Gap) 57 Transverse Marking, Thermoplastic, Crosswalk Line, White, 24 in. Line, Multi-Component, Broken, White, 6 in. (2' Line, 4' Gap) 39 Exist. Sign to Remain in Place Pavement Message Marking, Thermoplastic, Only58 38 Sign, Sheet, Relocate 1"=30' N/A RJC NRMNRM TJM PAVEMENT MARKINGS AND SIGN DETAILS - LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 80 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PM.02.dgn5/24/2021 10:28:56 AMtmckinney Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 116th Street 116th Street R a n g e Lin e Rd . Line "PR-S1A" Line "PR-RL1 " 3 5 W e s t fie ld Blv d . 32+80.00 "PR-S1A" BEGIN CONSTRUCTION 39+55.00 "PR-S1A" END CONSTRUCTION P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = YIELD YIELD YIELD YIELD MPH 15 48 48 48 48 43 43 47 47 47 47 45 45 54 54 53 ONEWAY Range Line Rd For Additional Details, see Roundabout Pavement Markings and Sign Details. All Stationing from Line "PR-S1A" Unless Otherwise Noted. NOTES: W16-7P (24" X 12") W11-2 (30" X 30") 35+07 D1-1d (48" X 10") 35+28 R1-2 (36" X 36" X 36") 36+85 R1-2 (36" X 36" X 36") 36+85 R3-8 (30" X 30") 38+40 W13-1P (18" X 18") W16-8P (42" X 18") W2-6 (30" X 30") 39+54 W16-7P (24" X 12") W11-2 (30" X 30") 37+36 R4-7 (24" x 30") 38+78 18.00' RT. +67.27 18.00' LT. +80.28 W16-7P (24" X 12") W11-2 (30" X 30") 37+07 D1-1d (48" X 10") 36+86 R1-2 (36" X 36" X 36") 35+27 R1-2 (36" X 36" X 36") 35+26 W16-7P (24" X 12") W11-2 (30" X 30") 34+81 R3-8 (30" X 30") 34+07 MPH 15 Range Line Rd 7.90' LT. +03.97 DWG. 10-38 See Carmel STD. 4-RPM (Yellow) 38 38 38 38 38 38 48 40 47 43 43 5.64' LT. +52.86 W13-1P (18" X 18") W16-8P (42" X 18") W2-6 (30" X 30") 33+50 DWG. 10-38 See Carmel STD. 4-RPM (Yellow) R4-7 (24" x 30") 33+52 44 116TH ST 116TH ST LEGEND 41 Line, Thermoplastic, Dotted, White, 8 in. (2' Line, 2' Gap) 46 47 44 Line, Thermoplastic, Solid, White, 4 in. Line, Thermoplastic, Solid, Yellow, 4 in. 42 "Sharks Teeth", Yield Line, White, See Carmel Standard Drawing 10-25B 40 45 48 Line, Thermoplastic, Solid, White, 6 in. 49 43 54 Line, Thermoplastic, Solid, Yellow, 8" Pavement Message Marking, Thermoplastic, Lane Indication Arrow, White Pavement Message Marking, Thermoplastic, Lane Indication Arrow, "Fishhook", White Transverse Marking, Thermoplastic, Crosswalk Line, White, 6"50 Transverse Marking, Thermoplastic, Crosshatch Line, Yellow, 12"53 Transverse Marking, Multi-Component, Pedestrian Crossing Line, Thermoplastic, Dotted, White, 4 in (3' Line, 9' Gap) 56 Line, Thermoplastic, Dotted, White, 6 in. (2' Line, 4' Gap) 57 Transverse Marking, Thermoplastic, Crosswalk Line, White, 24 in. Line, Multi-Component, Broken, White, 6 in. (2' Line, 4' Gap) 39 Exist. Sign to Remain in Place Pavement Message Marking, Thermoplastic, Only58 38 Sign, Sheet, Relocate TJM TJM NRM NRM N/A 1" = 30' SIGN DETAILS - LINE "PR-S1A" PAVEMENT MARKINGS AND BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 81 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PM.03.dgn5/24/2021 10:28:57 AMtmckinney Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 116th Street R a n g e Lin e Rd . Line "PR-S1A" Line "PR-RL1" 3 5 W e s t fie ld B lv d . P.C./P.T. 36+00.51 "PR-S1A" = P.C. 107+90.28 "PR-RL1" = 42 42 42 42 41 41 41 41 40 40 40 40 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 47 47 47 47 47 47 4747 44 44 44 44 ONEWAY ONEWAY ONEWAY ONEWAY 5757 57 57 57 57 57 57 All Stationing from Line "PR-RL1" Unless Otherwise Noted. NOTE: 13.73' LT. +08.45 30.05' LT. +14.15 20.47' LT. +25.59 23.14' RT. +07.21 32.06' RT. +25.59 73.60' RT. +48.57 D1-1d (48" x 10") 36+86 79.34' RT. +65.87 62.32' RT. +57.68 76.11' RT. +08.72 57.20' RT. +14.08 32.21' RT. +48.85 23.81' RT. +38.10 16.39' RT. +53.6916.10' LT. +54.25 26.25' LT. +34.38 D1-1d (48" x 10") 35+28 49.09' LT. +54.05 67.03' LT. +62.75 51.77' LT. +97.86 67.55' LT. +90.28 63.49' LT. +08.84 116TH ST 116TH ST R6-1(R) (36" x 12") 107+62 R6-1(R) (36" x 12") 107+63 R6-1(R) (36" x 12") 107+99 R6-1(R) (36" x 12") 107+99 LEGEND 41 Line, Thermoplastic, Dotted, White, 8 in. (2' Line, 2' Gap) 46 47 44 Line, Thermoplastic, Solid, White, 4 in. Line, Thermoplastic, Solid, Yellow, 4 in. 42 "Sharks Teeth", Yield Line, White, See Carmel Standard Drawing 10-25B 40 45 48 Line, Thermoplastic, Solid, White, 6 in. 49 43 54 Line, Thermoplastic, Solid, Yellow, 8" Pavement Message Marking, Thermoplastic, Lane Indication Arrow, White Pavement Message Marking, Thermoplastic, Lane Indication Arrow, "Fishhook", White Transverse Marking, Thermoplastic, Crosswalk Line, White, 6"50 Transverse Marking, Thermoplastic, Crosshatch Line, Yellow, 12"53 Transverse Marking, Multi-Component, Pedestrian Crossing Line, Thermoplastic, Dotted, White, 4 in (3' Line, 9' Gap) 56 Line, Thermoplastic, Dotted, White, 6 in. (2' Line, 4' Gap) 57 Transverse Marking, Thermoplastic, Crosswalk Line, White, 24 in. Line, Multi-Component, Broken, White, 6 in. (2' Line, 4' Gap) 39 Exist. Sign to Remain in Place Pavement Message Marking, Thermoplastic, Only58 38 Sign, Sheet, Relocate TJM TJM NRM NRM 1" = 20' N/A SIGN DETAILS - 116th ST. & RANGELINE RD. ROUNDABOUT PAVEMENT MARKINGS AND BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 82 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PM.ROUNDABOUT.116.dgn5/24/2021 10:28:58 AMtmckinney Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 10+90.00 "PR-S2A" BEGIN CONSTRUCTION 14+06.00 "PR-S2A" END CONSTRUCTION P.O.T. 12+32.76 "PR-S2A" P.O.T. 114+61.91 "PR-RL1"= Lin e "P R -R L1 " Line "PR-S2A" 1 0 1 5 1 1 5 + 0 0 R a n g e Lin e R d . Medical Dr. 49 49 49 49 44 44 48 48 40 40 40 40 41 41 41 41 42 42 42 42 54 54 53 53 53 54 47 47 47 47 47 YIELD YIELD All Stationing from Line "PR-S2A" Unless Otherwise Noted. NOTE: 48.73' RT. +20.57 49.00' RT. +25.69 48.83' RT. +29.79 22.94' RT. +00.60 11.36' RT. +77.89 10.80' RT. +57.93 +72.88 13.18' RT. W16-7P (24" X 12") W11-2 (30" X 30") 12+85 W16-7P (24" X 12") W11-2 (30" X 30") 13+13 D1-1d (48" x 10") 12+88 R1-2 (36" X 36" X 36") 12+84 38.91' LT. +55.47 18.63' LT. +71.01 6.49' LT. +59.06 45.49' LT. +43.9047.58' LT. +13.98 6.97' LT. +92.41 15.73' LT. +79.26 W16-7P (24" X 12") W11-2 (30" X 30") 11+59 3.56' LT. +25.34 3.44' RT. +25.47 W16-7P (24" X 12") W11-2 (30" X 30") 11+39 R1-2 (36" X 36" X 36") 11+68 MPH 15 Range Line Rd R4-7 (24" X 30") 13+35 W13-1P (18" X 18") W16-8P (42" X 18") W2-6 (30" X 30") 14+20 48 48 48 48 48 48(Typ.)18'-0" (Typ.) MedicalDr LEGEND 41 Line, Thermoplastic, Dotted, White, 8 in. (2' Line, 2' Gap) 46 47 44 Line, Thermoplastic, Solid, White, 4 in. Line, Thermoplastic, Solid, Yellow, 4 in. 42 "Sharks Teeth", Yield Line, White, See Carmel Standard Drawing 10-25B 40 45 48 Line, Thermoplastic, Solid, White, 6 in. 49 43 54 Line, Thermoplastic, Solid, Yellow, 8" Pavement Message Marking, Thermoplastic, Lane Indication Arrow, White Pavement Message Marking, Thermoplastic, Lane Indication Arrow, "Fishhook", White Transverse Marking, Thermoplastic, Crosswalk Line, White, 6"50 Transverse Marking, Thermoplastic, Crosshatch Line, Yellow, 12"53 Transverse Marking, Multi-Component, Pedestrian Crossing Line, Thermoplastic, Dotted, White, 4 in (3' Line, 9' Gap) 56 Line, Thermoplastic, Dotted, White, 6 in. (2' Line, 4' Gap) 57 Transverse Marking, Thermoplastic, Crosswalk Line, White, 24 in. Line, Multi-Component, Broken, White, 6 in. (2' Line, 4' Gap) 39 Exist. Sign to Remain in Place Pavement Message Marking, Thermoplastic, Only58 38 Sign, Sheet, Relocate TJM NRM TJM NRM 1" = 20' N/A SIGN DETAILS - MEDICAL DR. & RANGELINE RD. ROUNDABOUT PAVEMENT MARKINGS AND BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 83 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.PM.ROUNDABOUT.MED.dgn5/24/2021 10:28:59 AMtmckinney Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 See Special Provisions. All Sheet Sign Posts Shall be Black Powdercoated. NOTE: TJMTJM NRM NRM NONE N/A SHEET SIGN AND POST SUMMARY SHEET SIGN & POST SUMMARY SIGN POST NO. / LINE PLAN SHEET SIGN LOCATION SIGN CODE IN) (IN x SIZE SIGN MOUNTED SIGN GROUND - ON PANEL MOUNTED U CHANNEL SQUARE ROUND 2 1/4" x 2 1/4" - 12 GA. (TYPE 1)3-IN. (OD) ALUMINUM TUBE, NON-FLUTED POST LENGTH POST LENGTH REINFORCED ANCHOR 0.080"0.100"0.125"0.080"1 2 POST LENGTH (FT)POST LENGTH (FT)POST LENGTH FT.FT.FT.1 2 1 TOTAL (FT) Line "PR-RL1" 104+56 RT.W2-6 30X30 6.25 12.5 12.5 W16-8P 24X 8 1.34 W13-1P 18X18 2.25 105+56 RT.R3-8 30X30 6.25 10.5 10.5 105+75 LT.W4-2 (R)36X36 9 11.0 11.0 105+93 CTR.R4-7 24X30 5 10.5 10.5 106+53 RT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 106+82 LT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 107+01 CTR.R1-2 36X36 3.9 10.5 10.5 107+02 CTR.D1-1d 48X10 3.34 9.0 Dec. Street Sign Assembly 107+04 RT.R1-2 36X36 3.9 8.0 8.0 107+62 CTR.R6-1(R.)36X12 3 6.0 6.0 107+63 CTR.R6-1(R.)36X12 3 6.0 6.0 107+99 CTR.R6-1(R.)36X12 3 6.0 6.0 107+99 CTR.R6-1(R.)36X12 3 6.0 6.0 108+56 LT.R1-2 36X36 3.9 10.5 10.5 108+59 RT.D1-1d 48X10 3.34 9.0 Dec. Street Sign Assembly 108+60 CTR.R1-2 36X36 3.9 10.5 10.5 108+81 RT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 109+07 LT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 110+05 LT.R3-8 30X30 6.25 10.5 10.5 111+37 LT.W2-6 30X30 6.25 12.5 12.5 W16-8P 24X 8 1.34 W13-1P 18X18 2.25 111+77 RT.W2-6 30X30 6.25 3.9 12.5 12.5 W16-8P 30X 8 1.67 W13-1P 18X18 2.25 112+82 RT.R3-8 30X30 6.25 10.5 10.5 113+77 RT.W11-2 30X30 6.25 3.9 11.5 11.5 W16-7P 24X12 2 113+89 LT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 114+08 CTR.R1-2 36X36 3.9 10.5 10.5 114+12 RT.R1-2 36X36 3.9 10.5 10.5 115+13 CTR.R1-2 36X36 3.9 10.5 10.5 115+16 LT.R1-2 36X36 3.9 10.5 10.5 115+28 RT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 SHEET SIGN & POST SUMMARY SIGN POST NO. / LINE PLAN SHEET SIGN LOCATION SIGN CODE IN) (IN x SIZE SIGN MOUNTED SIGN GROUND - ON PANEL MOUNTED U CHANNEL SQUARE ROUND 2 1/4" x 2 1/4" - 12 GA. (TYPE 1)3-IN. (OD) ALUMINUM TUBE, NON-FLUTED POST LENGTH POST LENGTH REINFORCED ANCHOR 0.080"0.100"0.125"0.080"1 2 POST LENGTH (FT)POST LENGTH (FT)POST LENGTH FT.FT.FT.1 2 1 TOTAL (FT) Line "PR-RL1" 115+51 LT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 116+51 LT.R3-8 30X30 6.25 10.5 10.5 117+51 LT.W2-6 30X30 6.25 12.5 12.5 W16-8P 30X 8 1.67 W13-1P 18X18 2.25 Line "PR-S1A" 33+50 RT.W2-6 30X30 6.25 12.5 12.5 W16-8P 42X 8 2.34 W13-1P 18X18 2.25 33+52 CTR.R4-7 24X30 5 10.5 10.5 34+07 RT.R3-8 30X30 6.25 10.5 10.5 34+81 RT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 35+07 LT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 35+26 CTR.R1-2 36X36 3.9 10.5 10.5 35+27 RT.R1-2 36X36 3.9 10.5 10.5 35+28 CTR.D1-1d 48X10 3.34 9 Dec. Street Sign Assembly 36+85 LT.R1-2 36X36 3.9 10.5 10.5 36+85 CTR.R1-2 36X36 3.9 10.5 10.5 36+86 CTR.D1-1d 48X10 3.34 10.5 10.5 9 Dec. Street Sign Assembly 37+07 RT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 37+36 LT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 38+40 LT.R3-8 30X30 6.25 10.5 10.5 38+78 CTR.R4-7 24X30 5 10.5 10.5 39+54 LT.W2-6 30X30 6.25 12.5 12.5 W16-8P 42X 8 2.34 W13-1P 18X18 2.25 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 84 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SS.01.dgn5/24/2021 10:28:59 AMtmckinney Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 2 6 2.1 14.3 3 9.3 3 5.4 2 6 2 5.8 3.1 2 2 1 0 48 1.0" Border, Black on White; [Range Line Rd] B specified length; Standard Arrow Custom 7.2" X 6.0" 46{; Table of letter and object lefts. R 2.1 a 5.0 n 8.0 g 10.9 e 13.8 L 19.4 i 22.0 n 23.3 e 26.2 R 31.7 d 34.6 39.1 Range Line Rd 2 6 2.8 22.7 6 5.9 2 6 2 5.8 2.8 2 2 1 0 48 1.0" Border, Black on White; [Medical Dr] B; Standard Arrow Custom 7.2" X 6.0" 46{; Table of letter and object lefts. M 2.8 e 7.2 d 10.7 i 14.9 c 17.0 a 20.6 l 24.8 D 31.5 r 35.5 39.4 Medical Dr 2 4 4.8 12.1 4 8.2 4 4.1 4.8 2 8 42 Identifier : W16-8P; 1.5" Radius, 0.4" Border, 0.4" Indent, Black on Yellow; [Range Line Rd] B; Table of letter and object lefts. R 4.8 a 7.2 n 10.0 g 12.6 e 15.2 L 20.9 i 23.2 n 24.8 e 27.4 R 33.1 d 35.5 Range Line Rd 2 4 3.5 9.4 4 3.6 3.5 2 8 24 Identifier : W16-8P; 1.5" Radius, 0.4" Border, 0.4" Indent, Black on Yellow; [116th St] B; Table of letter and object lefts. 1 3.5 1 5.0 6 6.6 t 9.0 h 11.2 S 16.9 t 19.2 116th St 2 4 3.4 15.2 4 4 3.4 2 8 30 Identifier : W16-8P; 1.5" Radius, 0.4" Border, 0.4" Indent, Black on Yellow; [Medical Dr] B; Table of letter and object lefts. M 3.4 e 6.4 d 8.7 i 11.5 c 12.9 a 15.3 l 18.1 D 22.6 r 25.3 Medical Dr 2 6 5.5 13.8 6 5.4 2 6 5 5.8 6.5 2 2 1 0 48 1.0" Border, Black on White; [116TH St] B; Standard Arrow Custom 7.2" X 6.0" 46{; Table of letter and object lefts. 1 5.5 1 7.8 6 10.2 T 13.6 H 16.8 S 25.3 t 28.7 35.7 116TH St 2 6 2.6 22.5 2.3 10.2 2 6 2 5.8 2.6 2 2 1 0 48 1.0" Border, Black on White; [Westfield Blvd] B specified length; Standard Arrow Custom 7.2" X 6.0" 46{; Table of letter and object lefts. W 2.6 e 6.7 s 9.6 t 12.5 f 14.8 i 17.0 e 18.2 l 21.3 d 22.5 B 27.4 l 30.5 v 31.7 d 35.1 39.6 Westfield Blvd See Special Provisions. All Sheet Sign Posts Shall be Black Powdercoated. NOTE: 3 .1 1 25 .0 3 2.78 24.24 2.98 1.8 6 30 30 R3-8LT_TR_30x30; 2.25" Radius, 0.88" Border, 0.63" Indent, Black on White; TJMTJM NRM NRM NONE N/A SHEET SIGN AND POST SUMMARY SHEET SIGN & POST SUMMARY SIGN POST NO. / LINE PLAN SHEET SIGN LOCATION SIGN CODE IN) (IN x SIZE SIGN MOUNTED SIGN GROUND - ON PANEL MOUNTED U CHANNEL SQUARE ROUND 2 1/4" x 2 1/4" - 12 GA. (TYPE 1)3-IN. (OD) ALUMINUM TUBE, NON-FLUTED POST LENGTH POST LENGTH REINFORCED ANCHOR 0.080"0.100"0.125"0.080"1 2 POST LENGTH (FT)POST LENGTH (FT)POST LENGTH FT.FT.FT.1 2 1 TOTAL (FT) Line "PR-S2A" 11+39 RT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 11+59 LT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 11+68 RT.R1-2 36X36 3.9 10.5 10.5 12+84 LT.R1-2 36X36 3.9 10.5 10.5 12+88 CTR.D1-1d 48x10 3.34 9 Dec Street Sign Assembly 12+85 RT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 13+13 LT.W11-2 30X30 6.25 11.5 11.5 W16-7P 24X12 2 13+35 LT.R4-7 24X30 5 10.5 10.5 14+20 LT.W2-6 30X30 6.25 13.5 13.5 W16-8P 42X18 5.25 W13-1P 18X18 2.25 TOTAL 256 94 17 568 45 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 85 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SS.02.dgn5/24/2021 10:29:00 AMtmckinney Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 TJMTJM NRM NRM NONE N/A SUMMARY OF QUANTITIES AND APPROACH TABLE SUMMARY OF QUANTITIES AND APPROACH TABLE (STATION) LOCATION CLASS) TYPE OR (APPROACH DESCRIPTION W I D T H LE N G T H R A D I I L I N E B E Y O N D R / W D I S T A N C E R/W LINE SURFACE BEYOND N U R S E R Y S O D D I N G , A S P H A LT M I L L I N G , A S P H A LT M I L L I N G , SHOWN) 10% NOT THAN (LESS GRADE HMA MATERIAL FOR ROADS: T Y P E C I N S T A L L AT I O N , S T R U C T U R E H M A F O R S I D E W A LK H M A F O R H M A , T Y P E C W I D E N I N G W I T H T A C K C O A T A S P H A L T F O R B A S E S E AL JOINT ADHESIVE S E A L A N T LI Q U I D A S P H A LT W I T H P C C B A S E W I D E N I N G T R E A T M E N T S U B G R A D E A P P R O A C H E S P C C P F O R N O . 5 3 A G G R E G A T E C O M P A C T E D N O . 5 3 A G G R E G A T E C O M P A C T E D T R U C K AP R O N P A V E M E N T , C O N C R E T E D E C O R A T I VE C O N C R E T E S I D E W A L K , REMARKS B A S E A G G R E G A T E C O M P A C T E D H M A C O N C R E T E SURFACE INTERM.BASE BASE INTERM. OG. TYPE C, 9.5 mm TYPE C, 19.0 mm TYPE C, 25.0 mm TYPE C, 19.0 mm TYPE C, 19.0 mm MAINLINE MAINLINE MAINLINE MAINLINE MAINLINE DEPTH DEPTH "W""L""R"1.5 IN.VAR. % 165 #/SYS 275 #/SYS 385 #/SYS 330 #/SYS 250 #/SYS SURFACE INTERM.6 IN.IC II 6 in.9 in.6 IN.10 IN.7 IN.4 IN. ft.ft.ft.ft.SYS.SYS.SYS.TON TON TON TON TON TON TON TON TON TON LFT LFT LFT SYS.SYS.SYS.SYS.SYS.TON TON SYS.SYS. Line "PR-RL1"4,663 5,532 706 933 684 756 673 564 92 452 7 5 4,629 1,951 4,629 939 7,327 624 197 352 729 105+16.44 Lt.Class III Drive 24 26.0 20 20 12.5 x 87 87 106+27.55 Rt.Class III Drive 33.5 12.3 20 10 x 55 55 109+26.60 Rt.Mod. Class III 54.1 18.5 7 5 2.7 x 85 85 109+99.00 Rt.Mod. Class III 35.7 18.7 30 15 0.5 x 68 68 110+91.10 Lt.Mod. Class III 35.6 16.8 30 30 3.9 x 94 94 110+93.30 Rt.Class III Drive 28 26.2 20 10 13.8 x -14%108 108 112+64.40 Rt.Class III Drive 25.4 26.2 20 10 3.4 x 71 71 117+22.60 Rt.Class III Drive 56.6 34.3 20 10 15.3 x -10.5%136 136 117+81.60 Rt.Class III Drive 37.2 31.1 20 10 12.1 x 120 120 118+61.10 Lt.Mod. Class III 25.2 27.4 30 30 8.4 x 118 118 119+02.00 Rt.Class III Drive 26.5 19.0 20 20 73 73 119+97.70 Rt.Mod. Class III 21.1 19.0 20 20 62 62 120+44.60 Lt.Mod. Class III 23.3 21.4 15 15 7.4 x 65 65 121+03.50 Lt.Mod. Class III 25.9 17.2 15 15 3.1 x 57 57 121+61.10 Rt.Mod. Class III 34.5 22.1 20 20 3.1 x 98 98 122+21.70 Lt.Mod. Class III 28.2 17.3 20 17 69 69 122+90.50 Lt.Mod. Class III 24.9 14.6 17 15 51 51 123+43.70 Lt.Class III Drive 31.3 13.5 10 20 56 56 123+48.30 Rt.Mod .Class III 24.7 17.4 20 20 63 63 124+19.10 Lt.Mod. Class III 33.8 18.7 15 10 89 89 Line "PR-S1A"1137.0 1303.0 250 216 302 268 235 31 33 2 2 1283 690 1283 108 2135 162 324 33+10.20 Rt.Class III Drive 26.5 11.8 15 20 x 43 43 33+83.30 Lt.Mod. Class III 27.5 40.8 30 30 158 158 37+95.40 Lt.Mod. Class III 44.6 36.4 20 30 9.0 x 185 185 38+52.53 Rt.Class III Drive 30.5 13.0 15 15 x 54 54 39+10.70 Lt.Mod. Class III 50.1 19.3 10 20 118 118 TOTALS 5,800 6,835 706 1,183 900 1,058 941 799 92 483 33 9 7 5,912 2,641 5,912 1,047 9,462 2,183 2,183 786 197 352 1,053 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 86 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.AP.01.dgn5/24/2021 11:34:07 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 JAB RJC NRM NRM UNDERDRAIN TABLE N/A N/A UNDERDRAIN TABLE UNDERDRAIN PIPE OUTLET PIPE OUTLET PROTECTORS REMARKS P IP E LI M IT S U N D ER D RAI N TYPE 4 PIPE U N D ER D R AI N S FO R GEO TE XT ILE S U N D ER D R AI N S AG R E G A T E FO R U N D ER D R AI N S H MA FO R S P E C IAL G RAD E LI M IT UN D ER D R AIN P IP E FLO W EL E VA TI O N @ R EQ U I RE D O U TL E T P I P E T O STR UC T UR E N O . UN D ER D R AIN P IP E CO N N E CT EL E VA T IO N S T RUCTU RE IN V E RT R EQ U I RED (1 O R 2 ) 4 5 D E G RE E E L BO W S P IP E 6 I N O U TL E T O U T L E T S T AT IO N O U T L E T E L E VA TI O N P R O T E C T O R N O . O U T L E T AT O U T L E T O U T L E T P R O TE CT O R EL E VA T IO N AT D ITCH FLO W LINE NO . P IP E T O S T R U CT U RE C O N N E C T O U T L E T EL E VA T IO N S T RUCTU RE IN V E RT BACKFI LL S T RU CT U RE B BO R R O W FO R UN D E RD R AIN H MA FO R N O . _ _ _ _ O U T L E T P R O TE CT O R TYP E O U T L E T P R O TE CT O R LOCATION 4 IN . 6 IN . LE F T O U TS I D E LE F T M ED I AN R IG H T M ED I AN R IG H T O U TS I D E FT.FT.SYS.CYS.TON (%)(Y/N)LFT.CYS.TONS LINE "PR-RL1" OUTSIDE LEFT 104+00.0 98.8 89 9 813.71 N Connect to 16-SW-85 Underdrain 104+98.8 814.09 N 104+98.8 187.2 168 17 814.16 N 301 106+86.0 815.68 N 106+86.0 117.1 105 11 815.68 N 306 815.50 34+80.0 "PR-S1A" Rt.815.73 N 346 814.20 35+11.0 "PR-S1A" Lt. 85.9 77 8 815.88 N 348 812.15 108+80.0 816.18 N 108+80.0 152.0 137 14 816.18 N 310 815.73 110+31.6 817.01 N 110+31.6 32.3 29 3 817.01 N 314 814.63 110+63.9 817.12 N 110+63.9 329.1 296 30 817.12 N 317 816.57 113+93.0 821.38 N 113+99.0 95.1 86 9 822.25 N 502 821.25 Modified Depth 11+36.0 "PR-S2A" Rt.823.51 N 519 823.00 Modified Depth 115+62.0 238.0 214 21 826.30 N 512 825.50 118+00.0 834.95 N 118+00.0 235.2 212 21 834.95 N 516 834.50 120+35.2 839.02 N 120+35.2 323.1 291 29 839.02 N 319 836.19 123+58.3 843.67 N 123+58.3 63.8 57 6 843.67 N 124+22.1 842.66 N 327 840.48 124+22.1 8.0 7 1 842.66 N 327 840.48 124+30.0 842.76 N Inlet perimeter drain, cap pipe end (see Misc. Details) LINE "PR-RL1" OUTSIDE RIGHT 104+00.0 56.6 51 5 813.94 N Connect to 16-SW-85 Underdrain 104+56.6 813.77 N 300 811.94 104+56.6 123.4 111 11 813.77 N 300 811.94 105+80.0 814.63 N 105+80.0 99.0 89 9 814.63 N 302 814.03 106+79.0 815.66 N 106+79.0 95.5 86 9 815.66 N 305 815.15 37+03.0 "PR-S1A" Rt.815.73 N 349 815.20 Modified Depth (2.88 Underdrain Elev. Drop) 37+06.0 "PR-S1A" Lt.111.3 100 10 815.38 N 350 814.53 108+98.0 816.38 N 108+98.0 133.9 121 12 816.38 N 312 815.68 110+34.0 816.91 N 110+34.0 367.0 330 33 816.91 N 315 814.90 114+01.0 821.58 N SUBTOTALS =2,952 2,656 268 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 87 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.UD.01.dgn5/24/2021 09:46:04 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 UNDERDRAIN TABLE JAB NRM NRM RJC N/A N/A UNDERDRAIN TABLE UNDERDRAIN PIPE OUTLET PIPE OUTLET PROTECTORS REMARKS P I P E LI MITS U N D E R D RAI N TYPE 4 PIPE U N D E R D RAI N S F O R G EO T E XTI LE S U N D E R D RAI N S AG REG A T E F O R U N D E R D RAI N S H M A F O R S P ECI AL GR AD E LIMI T U N D ER D RAI N P IP E FLO W E L E VA T I O N @ R E Q U IR ED O U T L E T P I P E T O S T R U CT U R E NO . U N D ER D RAI N P IP E CO N N ECT E L E VA TI O N STR U C T UR E I NV ER T R E Q U IR ED ( 1 O R 2 ) 4 5 D EG REE EL BO W S PI PE 6 I N O U T L E T O U TL E T S T ATI O N O U T L E T E L E VA T I O N P R O TE CT O R NO . O U T L E T AT O U T L E T O U T L E T P RO T E CTO R EL E VA T I O N AT DI T C H F LO W LI N E N O . P I P E TO S T RUCTURE CO N N ECT O U T L E T E L E VA TI O N STR U C T UR E I NV ER T BAC KF ILL S T R UCTUR E B BO RR O W F O R U N D ER D R AI N H M A F O R N O ._ _ _ _ O U T L E T P RO T E CTO R T YP E O U T L E T P RO T E CTO R LOCATION 4 I N . 6 I N . LE F T O U T SI D E LE F T M E D I AN R IGH T M E D I AN R IGH T O U T SI D E FT.FT.SYS.CYS.TON (%)(Y/N)LFT.CYS.TONS LINE "PR-RL1" OUTSIDE RIGHT 114+07.0 40.0 36 4 821.88 N 505 821.10 114+40.0 823.08 N High point 12+90.0 "PR-S2A" Lt.72.0 65 6 823.68 N 521 823.00 115+53.0 826.04 N 115+60.0 311.0 280 28 826.30 N 511 825.00 118+71.0 836.38 N 118+71.0 165.0 149 15 836.38 N 318A 832.52 120+36.0 838.97 N 120+36.0 333.3 300 30 838.97 N 320 837.99 123+73.7 843.08 N 123+73.7 58.3 52 5 843.08 N 124+32.0 842.85 N 328 841.82 LINE "PR-S1A" OUTSIDE LEFT 32+80.0 141.0 127 13 818.52 N Connect to existing underdrain 34+21.0 816.18 N 343 814.20 34+68.0 5.0 5 1 815.75 N Inlet perimeter drain, cap pipe end (see Misc. Details) 34+73.0 815.69 N 344 813.70 35+06.0 5.0 5 1 815.90 N Inlet perimeter drain, cap pipe end (see Misc. Details) 35+11.0 815.86 N 348 812.15 37+06.0 101.0 91 9 815.43 N 38+07.0 814.29 N 354 812.66 38+13.0 5.0 5 1 814.31 N 356 812.67 38+18.0 814.36 N Inlet perimeter drain, cap pipe end (see Misc. Details) 38+47.0 108.0 97 10 814.18 N 358 812.85 39+55.0 816.18 N Connect to existing underdrain LINE "PR-S1A" OUTSIDE RIGHT 32+80.0 136.7 123 12 818.55 N Connect to existing underdrain 34+20.0 816.05 N 342 814.50 34+69.0 5.0 5 1 815.77 N Inlet perimeter drain, cap pipe end (see Misc. Details) 34+74.0 815.72 N 345 814.25 37+03.0 104.0 94 9 815.48 N 38+07.0 814.24 N 355 812.60 38+13.0 35.0 32 3 814.24 N 357 812.62 38+48.0 814.38 N Do not disturb existing 48-in. culvert under 116th St. LINE "PR-S2A" OUTSIDE LEFT 12+90.0 116.0 104 10 823.68 N 14+06.0 821.38 N Connect to existing underdrain SUBTOTALS =1,741 1,570 158 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 88 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.UD.02.dgn5/24/2021 09:46:05 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 NRM RJCJAB NRM UNDERDRAIN TABLE N/A N/A UNDERDRAIN TABLE UNDERDRAIN PIPE OUTLET PIPE OUTLET PROTECTORS REMARKS PI PE LIMI T S UN D ERDR AIN TYPE 4 PIPE UN D ERDR AIN S FO R G E O T E XT I LE S UN D ERDR AIN S AG R EG A TE F O R UN D ERDR AIN S H MA FO R S P ECI AL G R AD E LIM I T UN D E RD R AIN PI PE F LO W EL E VA T IO N @ RE Q U IR ED O U T L E T P IP E TO S T RUCTU RE N O . UN D E RD R AIN PI PE C O N N EC T EL E VA T IO N S T R U CT U R E I N V E R T REQ U I R E D ( 1 O R 2 ) 4 5 D EGR EE EL BO W S P IP E 6 IN O U T L E T O U T L E T STATI O N O U TL E T EL E VA T IO N P RO T E CTO R N O . O U TL E T AT O U TL E T O U TL E T P R O T E C T O R E L E VA TI O N AT D I T CH FLO W LIN E N O . PI PE T O STR U C T UR E CO N N ECT O U TL E T EL E VA T IO N S T R U CT U R E I N V E R T B ACKFI LL STR U C T UR E B BO R R O W FO R U N D ER D RAI N H MA FO R NO ._ _ _ _ O U TL E T P R O T E C T O R T YPE O U TL E T P R O T E C T O R LOCATION 4 I N . 6 I N . LE FT O U T S ID E LE FT ME D IAN RI G H T ME D IAN RI G H T O U T S ID E FT.FT.SYS.CYS.TON (%)(Y/N)LFT.CYS.TONS LINE "PR-S2A" OUTSIDE RIGHT 10+90.0 46.0 41 4 824.34 N 11+36.0 823.51 N 519 823.00 Modified Depth 12+75.0 125.0 113 11 823.08 N 14+06.0 821.74 N Connect to existing underdrain SUBTOTALS =171 154 15 TOTALS =4,865 4,380 441 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 89 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.UD.03.dgn5/24/2021 09:46:06 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 TJMTJM NRM NRM NONE N/A STRUCTURE DATA TABLE STRUCTURE DATA NU MBER S T RUCTU RE LOCATION SIZE DESCRIPTION LE NG TH S KEW FLOW LINE SERVI CE LI FE DES I G N A T IO N S I T E p H M ET HO D B ACKFI LL B ACKFI LL S T R U C T U R E T YP E B ACKFI LL FLO W AB LE T YP E G E O T E XT I LE S R IP RAP R EVET MEN T SCOUR PROTECTION S T R UCTUR ES CLAS S A, FO R C O N CR ET E , INS P ECTI O N VID EO S E C T IO N P I P E E ND END SECTION GRATED BOX END SECTION SAFETY METAL N O . C O N N EC T T O S T R. REMARKS STATION LE F T R IG H T C R O S S O FF S E T R C P C LAS S SPECIALTY STRUCTURE AND TYPE MANHOLE, INLET, CATCH BASIN, OR CO V ER STREAM UP STREAM DOWN D EP T H S U M P E G EO T E XTI L R IP RAP FT IN LFT FT ELEV.ELEV.YR.CYS CYS SYS TON IN SYS TYPE TONS CYS LFT EA TYPE SLOPE EA TYPESLOPE EA Line PR-RL1 300 104+56.6 x Existing Inlet Adjust Casting to Grade 301 104+98.8 x Existing Inlet Casting, 13, Furnish and Adjust Casting to Grade 302 105+80.0 x 12 III Inlet J-10 5 1.9 814.03 814.00 75 N/A 7 1 1.6 2 303 303 105+80.0 x 40.5 42 III Manhole K-4 4 5.2 75 N/A 7 1 7.3 2 Flat Casting Req'd, Furnish and Adjust to Grade; Connect to Exist. Trunkline 303A 106+45.0 x 53.5 12 III Inlet J-10 43 1.0 815.63 815.50 75 N/A 7 1 8.9 2 306 304 106+48.3 x 43.5 Existing Manhole Flat Casting Req'd, Furnish and Adjust to Grade 305 106+79.0 x 12 III Manhole C-10 26 1.4 815.15 815.00 75 N/A 7 1 6.7 2 304 306 106+86.0 x 12 III Manhole C-10 74 1.3 815.50 815.15 75 N/A 7 1 18.4 2 305 307 107+67.0 x 42.3 Existing Manhole Reconstruct Manhole 2 LFT 308 108+24.7 x 7.2 Existing Manhole Reconstruct Manhole 2 LFT and Rotate Lid to be Out of Curb Line 309 108+73.1 x 6.5 Existing Manhole Adjust Casting to Grade 310 108+80.0 x 12 III Inlet J-10 41 1.8 815.73 815.50 75 N/A 7 1 12.8 2 309 311 INTENTIONALLY OMITTED 312 108+98.0 x 12 III Inlet R-13 32 1.8 815.68 815.50 75 N/A 7 1 10.0 2 309 313 INTENTIONALLY OMITTED 314 110+31.6 x Existing Inlet Adjust Casting to Grade 315 110+34.0 x Existing Inlet Adjust Casting to Grade 316 110+34.2 x 13.9 Existing Manhole To Remain As Is 317 110+63.9 x Existing Inlet Adjust Casting to Grade 317A 112+55.9 x 14.8 Existing Manhole To Remain As Is 318 118+70.9 x 18.6 Existing Manhole Adjust Casting to Grade 318A 118+71.0 x 12 III Inlet R-13 4 5.1 832.52 832.36 75 N/A 7 1 3.1 2 318 319 120+35.2 x Existing Inlet Adjust Casting to Grade 320 120+36.0 x Existing Inlet Adjust Casting to Grade 321 120+38.6 x 33.4 Existing Manhole Flat Casting Req'd, Furnish and Adjust to Grade 322 121+26.6 x 31.2 Existing Manhole Flat Casting Req'd, Furnish and Adjust to Grade 323 121+50.0 x 12 III Inlet E-7 24 1.0 841.12 841.00 75 N/A 7 1 5.1 2 322 324 123+57.9 x 40.4 Existing Manhole Flat Casting Req'd, Furnish and Adjust to Grade 325 123+58.3 x Existing Inlet Adjust Casting to Grade 326 123+73.7 x Existing Inlet Adjust Casting to Grade 327 124+22.1 x Existing Inlet Adjust Casting to Grade 328 124+32.0 x Existing Inlet Adjust Casting to Grade Line "PR-S1A" #N/A III Existing Inlet ###########N/A #N/A 75 N/A 7 1 16.6 2 328 341 34+14.9 x 12 III Pipe 6 2.0 815.03 815.00 75 N/A 7 1 2.0 2 343 342 34+20.0 x 12 III Inlet J-10 52 2.6 814.50 814.25 75 N/A 7 1 21.7 2 345 To Remain As Is BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 90 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SD.01.dgn5/24/2021 09:46:06 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 TJMTJM NRM NRM NONE N/A STRUCTURE DATA TABLE STRUCTURE DATA NU MBER S T RUCTU RE LOCATION SIZE DESCRIPTION LE NG TH S KEW FLOW LINE SERVI CE LI FE DES I G N A T IO N S I T E p H M ET HO D B ACKFI LL B ACKFI LL S T R U C T U R E T YP E B ACKFI LL FLO W AB LE T YP E G E O T E XT I LE S R IP RAP R EVET MEN T SCOUR PROTECTION S T R UCTUR ES CLAS S A, FO R C O N CR ET E , INS P ECTI O N VID EO S E C T IO N P I P E E ND END SECTION GRATED BOX END SECTION SAFETY METAL N O . C O N N EC T T O S T R. REMARKS STATION LE F T R IG H T C R O S S O FF S E T R C P C LAS S SPECIALTY STRUCTURE AND TYPE MANHOLE, INLET, CATCH BASIN, OR CO V ER STREAM UP STREAM DOWN D EP T H S U M P E G EO T E XTI L R IP RAP FT IN LFT FT ELEV.ELEV.YR.CYS CYS SYS TON IN SYS TYPE TONS CYS LFT EA TYPE SLOPE EA TYPESLOPE EA Line "PR-S1A" 343 34+21.0 x 12 III Manhole J-10 46 2.7 814.20 813.95 75 N/A 7 1 19.8 2 344 344 34+73.0 x 15 III Inlet M-10 3 3.1 813.70 813.68 75 N/A 7 1 1.6 2 347 345 34+74.0 x 12 III Inlet M-10 3 2.6 814.25 814.20 75 N/A 7 1 1.3 2 346 346 34+80.0 x 12 III Inlet M-10 46 2.6 814.20 813.95 75 N/A 7 1 19.2 2 348A 347 34+80.0 x 15 III Inlet M-10 26 3.1 813.68 813.55 75 N/A 7 1 14.0 2 348 348 35+11.0 x 18 III Manhole J-10 7 4.2 812.15 812.12 75 N/A 7 1 5.4 2 Connect to Exist. Trunkline 348A 35+17.5 x 12 III Manhole C-4 33 2.5 813.95 813.75 75 N/A 7 1 13.3 2 348 349 37+03.0 x 12 III Manhole C-10 63 1.7 815.20 814.90 75 N/A 7 1 18.9 2 307 350 37+06.0 x 12 III Inlet J-10 3 2.0 814.53 814.50 75 N/A 7 1 1.0 2 351 351 37+09.0 x 45.5 21 III Manhole C-4 4 4.8 75 N/A 7 1 3.8 2 Flat Casting Req'd, Furnish and Adjust to Grade; Connect to Exist. Trunkline 352 37+73.2 x 33.6 21 III Manhole K-4 2 4.5 75 N/A 7 1 1.8 2 Connect to Exist. Trunkline 353 38+04.0 x 67.5 12 III Inlet R-13 44 1.1 812.71 812.50 75 N/A 7 1 9.8 2 352 354 38+07.0 x 12 III Inlet R-13 32 2.4 812.66 812.50 75 N/A 7 1 12.5 2 352 355 38+07.0 x 15 III Inlet M-10 70 2.4 812.60 812.25 75 N/A 7 1 30.5 2 352 356 38+13.0 x 12 III Inlet R-13 3 2.7 812.67 812.66 75 N/A 7 1 1.3 2 354 357 38+13.0 x 12 III Inlet J-10 2 2.7 812.62 812.60 75 N/A 7 1 0.9 2 355 358 38+47.0 x 12 III Inlet J-10 33 2.6 812.85 812.67 75 N/A 7 1 13.8 2 356 Existing Sanitary "PR-RL1" 400 108+43.8 x 37.7 Existing Sanitary Manhole Reconstruct Manhole 2 LFT 401 110+30.6 x 36.7 Existing Sanitary Manhole Flat Casting Req'd, Furnish and Adjust to Grade 401A 112+45.9 x 33.0 Existing Sanitary Manhole Flat Casting Req'd, Furnish and Adjust to Grade 401B 114+60.1 x 32.6 Existing Sanitary Manhole Adjust Casting to Grade "PR-S1A" 402 37+07.7 x 13.5 Existing Sanitary Manhole Reconstruct Manhole 2 LFT Medical Dr. Line "PR-RL1" 501 113+93.0 x 12 III Inlet M-10 45 1.1 821.20 821.00 75 N/A 7 1 10.1 2 503 502 113+99.0 x 12 III Inlet M-10 3 1.1 821.25 821.20 75 N/A 7 1 0.7 2 501 503 114+01.0 x 15.5 36 III Manhole J-4 2 2.4 818.34 818.30 75 N/A 7 1 1.6 2 Connect to Exist. Trunkline. 2 LFT of 36" Pipe Req'd on Upstream Side As Well 504 114+01.0 x 12 III Inlet M-10 6 1.4 821.05 821.00 75 N/A 7 1 1.6 2 503 505 114+07.0 x 12 III Inlet J-10 2 1.4 821.10 821.05 75 N/A 7 1 0.5 2 504 506 115+17.1 x 16.2 Existing Manhole Adjust Casting to Grade 507 115+18.5 x 48.2 Existing Manhole Reconstruct Manhole 2 LFT and Flat Casting Req'd, Furnish and Adjust to Grade 508 115+53.0 x 12 III Inlet J-10 3 2.1 825.02 825.00 75 N/A 7 1 1.1 2 511 509 115+55.0 x 12 III Inlet J-10 3 1.6 825.52 825.50 75 N/A 7 1 0.9 2 512 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 91 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SD.02.dgn5/24/2021 09:46:46 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 TJMTJM NRM NRM NONE N/A STRUCTURE DATA TABLE STRUCTURE DATA NU MBER S T RUCTU RE LOCATION SIZE DESCRIPTION LE NG TH S KEW FLOW LINE SERVI CE LI FE DES I G N A T IO N S I T E p H M ET HO D B ACKFI LL B ACKFI LL S T R U C T U R E T YP E B ACKFI LL FLO W AB LE T YP E G E O T E XT I LE S R IP RAP R EVET MEN T SCOUR PROTECTION S T R UCTUR ES CLAS S A, FO R C O N CR ET E , INS P ECTI O N VID EO S E C T IO N P I P E E ND END SECTION GRATED BOX END SECTION SAFETY METAL N O . C O N N EC T T O S T R. REMARKS STATION LE F T R IG H T C R O S S O FF S E T R C P C LAS S SPECIALTY STRUCTURE AND TYPE MANHOLE, INLET, CATCH BASIN, OR CO V ER STREAM UP STREAM DOWN D EP T H S U M P E G EO T E XTI L R IP RAP FT IN LFT FT ELEV.ELEV.YR.CYS CYS SYS TON IN SYS TYPE TONS CYS LFT EA TYPE SLOPE EA TYPESLOPE EA Line "PR-RL1" 510 115+60.0 x 16.4 36 III Manhole J-4 2 4.2 822.32 822.25 75 N/A 7 1 1.3 2 Connect to Exist. Trunkline. 2 LFT of 36" Pipe Req'd on Upstream Side As Well 511 115+60.0 x 12 III Inlet M-10 5 3.3 825.00 824.97 75 N/A 7 1 2.6 2 510 512 115+62.0 x 12 III Inlet M-10 37 2.9 825.50 825.30 75 N/A 7 1 16.9 2 510 513 115+96.1 x 16.6 Existing Manhole To Remain As Is 514 116+04.9 x 31.4 Existing Inlet Adjust Casting to Grade 515 116+71.7 x 60.9 Existing Manhole To Remain As Is 516 118+00.0 x 12 III Inlet J-10 39 2.5 834.50 834.30 75 N/A 7 1 16.2 2 517 517 118+00.0 x 18.0 36 III Manhole J-4 2 5.7 829.70 829.65 75 N/A 7 1 1.9 2 Connect to Exist. Trunkline. 2 LFT of 36" Pipe Req'd on Upstream Side As Well Line "PR-S2A" 518 11+35.0 x 12 III Inlet M-10 25 2.6 822.90 822.75 75 N/A 7 1 11.6 2 520 519 11+36.0 x 12 III Inlet J-10 17 2.2 823.00 822.90 75 N/A 7 1 6.2 2 518 520 11+62.0 x 12 III Inlet M-10 89 2.3 822.75 821.25 75 N/A 7 1 33.6 2 502 521 12+90.0 x 12 III Inlet J-10 41 2.3 823.00 822.80 75 N/A 7 1 15.5 2 506 BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK DESIGN ENGINEER DATE CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 92 FOR APPROVAL RECOMMENDED P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.SD.03.dgn5/24/2021 09:47:23 AMjhofman Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 129 05/07/2021 No. ANAIDNI DERETSIGER REE NIGNE LANOIS S EFO R P STATE OF Y HPR U M .R SALOHCIN 11400799 A/ C A/ C A/ C A/ C M O N LD LDLD LD LD LD LD E M E M E M E M E G M P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T M A G M A G M O N M O N M O N M O N M O N M O N M O N M O N M O N M O N W W W WW W W W W W W WW W W W P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T R B - 0 R B - 0 TT T T H H H H H H H H H H H C C - T R C W V W V M O N M B W V P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T FF E P P S T C C - T R T H W V C W V H T H E M W V R B - 0 M A G R B - 0 PZ Z Z PZ Z Z PZ Z Z H H H (1 - s t y b r i c k 1 8 . 1 ' t a l l ) (g a s p u m p s ) (g a s p u m p s ) (g a s p u m p s ) (g a t e ) (b r i c k W a l g r e e n s ) (block car wash) (1 - s t y b l o c k g a s s t a t i o n ) 1 2 " r c p 4" p v c 42" rcp42" rcp 12 " r c p 12" rcp 12 " r c p 1 2 " r c p 12" rcp 8" pvc8" p v c 8" p v c 30" rcp 12" r c p 6" pv c 30 " r c p 12 " r c p 8" p v c 21" r c p 12" rcp 12" cpp 12 " c m p 21" rcp 12" cpp 12" cpp 12 " c p p 12" rcp 12" rcp 12" rcp 12" rcp 12" r c p 42" rcp 21 " r c p 6" vcp 2" pvc 6" p v c 8" vcp 8" p v c 8" v c p 8" vcp 12 " v c p 12 " v c p 12 " r c p 18 " r c p 42" rcp 12 " r c p 42" rcp 12 " r c p 12 " r c p 12 " r c p 12" rc p 12" cpp 12 " r c p T P P S T (2 - s t y s t o n e ) c o n c . conc. conc. c o n c . c o n c . c o n c . c o n c . conc. conc. conc. conc. conc. conc. conc. conc. conc. conc. conc. c o n c . c o n c . c o n c . c o n c . c o n c . conc. co n c . c o n c . conc. c o n c . c o n c . c o n c . c o n c . gr a s s gr a s s gra s s gr a s s gr a s s gra s s gr a s s grass grassgrass grass grassgrass grass grass grass gr a s s grass grass gra s s gr a s s grass gr a s s grass gr a s s gr a s s gr a s s gr a s s gr a s s gra s s gr a s s gr a s s wo o d s wo o d s as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t asphalt as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t ri p r a p ri p r a p planter planter pla n t e r pl a n t e r pla n t e r pla n t e r planter pl a n t e r pl a n t e r pla n t e r pla n t e r pla n t e r pl a n t e r pla n t e r planter pla n t e r planter pl a n t e r planter pla n t e r pla n t e r pla n t e r pla n t e r conc. bu s h e s 42" rcp 48" rcp 3" p v c - f o r c e m a i n 3" pvc - forcemain 3" p v c - f o r c e m a i n 3" pvc - forcemain W V 17 + 0 0 18 + 0 0 19 + 0 0 20 + 0 0 21 + 0 0 22 + 0 0 23 + 0 0 24 + 0 0 RANGELINE RD. 11 6 T H S T . RANGELINE RD. Line "PR-RL1" Temp. R/W Ap p . E x i s t . R / W R/W R / W T e m p . R / W Temp. R/W Temp. R/W Temp. R/W Temp. R/W Temp. R/W R/W R/W R/W App. Exist. R/W App. Exist. R/W CORNER ASSOCIATESLP CORNER ASSOCIATESLP KRG CENTRE LLC S MART REAL ESTATEINC SPEEDWAY LLC VCA REAL PROPERTYACQUISITIONCORPORATION KRG CENTRE LLC INSTALL NEW HYDRANT ASSEMBLY RETIRE HYDRANT ASSEMBLY AND VALVE 295 LFT OF 12" HDPE SDR11 VIA HDD RETIRE VALVE RETIRE HYDRANT ASSEMBLYAND VALVE 45° MJ BEND ADJUST VALVE TO GRADE MJ HARVEY ADAPTER WATER STOP 12"x12" MJ TEE (2) GATE VALVES 11 LFT OF 12" DI 12"x12" MJ TEE (2) GATE VALVES MJ HARVEY ADAPTER WATER STOP 243 LFT OF 12"HDPE SDR11 VIA HDD MJ HARVEY ADAPTER WATER STOP 45° MJ BEND 14 LFT OF 12" DI 12" CONNECTION 45° MJ BEND MJ HARVEY ADAPTER WATER STOP 425 LFT OF 12" HDPE SDR11 VIA HDD INSTALL NEW HYDRANT ASSEMBLY App. Exist. R/W RETIRE HYDRANT ASSEMBLY AND VALVE 6" ELECTRO FUSION SADDLE 6" GATE VALVE 31 LFT OF 12" DI (2) 45° MJ BENDs HARVEY ADAPTER WATER STOP 100 LFT OF 12" HDPE SDR11 VIA HDD6" ELECTRO FUSION SADDLE 6" GATE VALVE INSTALL NEW HYDRANT ASSEMBLY 50 LFT OF 6" RESTRAINED JOINT DI RETIRE VALVE PLUG AT TEE ADJUST VALVE TO GRADE 12" CONNECTION 12"x12" TAPPING SADDLE 12" TAP VALVE 59 LFT OF 12" DI 45° MJ BEND D.B. 16-ENG-37 . RECOMMENDEDFOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALE CITY OF CARMEL D.B. J.C.B. D.B. . . VERTICAL SCALE 129 N/A 1"=30' DI R E C T O R Y P A T H : R : \ A c t i v e \ C a r m e l U t i l i t i e s \ C a r m e l B o n d P r o j e c t s \ R a n g e l i n e & 1 1 6 t h \ C A D \ 1 1 6 t h R a n g e l i n e D e s i g n FI L E N A M E : W a t e r p l a n s . d w g DA T E / U S E R : 5 / 1 2 / 2 0 2 1 4 : 4 8 P M / C b e n n e t t WPO N TE E. SINTE E T R IN E N G EE R A NDNILONA O EF ISSI A STATE OF 19700381 RGE DE RRT P R CROSSROAD ENGINEERS, P.C. WATER PLANS LINE "PR-RL1" NOTES:1)SURVEY INFORMATION WAS PROVIDED BY STRUCTURE POINT. CROSSROAD ENGINEERS ISRESPONSIBLE FOR THE WATER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANYDISCREPANCIES WITH THE SURVEY, PLEASE CONTACT STRUCTURE POINT AT (317) 547-5580.2)ROAD PLAN INFORMATION WAS PROVIDED BY STRUCTURE POINT. CROSSROAD ENGINEERS ISRESPONSIBLE FOR THE WATER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANYDISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT STRUCTURE POINT AT (317) 547-5580. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFYALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORTANY DISCREPANCIES TO THE WATER MAIN DESIGNER.4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCEWITH INDOT, CEG, OR CWU STANDARDS AND SPECIFICATIONS.5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITHROAD PROJECT IMPROVEMENTS. PROPOSED LEGEND PROPOSED WATER MAIN COMPLETE HYDRANT ASSEMBLY SHORT SIDE SERVICE GATE VALVE TEE MJ PLUG MJ CAP THRUST BLOCK SS 11.25° MJ BEND 22.5° MJ BEND 45° MJ BEND NOTES 1. CONTRACTOR TO FIELD VERIFY EXISTING WATER MAIN FOR SIZE,TYPE & LOCATION AT ALLCONNECTION & DISCONNECT LOCATIONS. 2. VALVE KEY EXTENSIONS ARE TO BE USED FOR ANY VALVE KEY BELOW 4' FROM FINISHED GRADE. 3. CONTRACTOR TO DEFLECT PIPE AND USE MJ BENDS AS NECESSARY OR AS DIRECTED BY C.W.U. PERSONNEL TO STAY ON PROPOSED ALIGNMENT AND AVOID EXISTING AND PROPOSED STRUCTURES, PIPES AND UTILITIES. 4. CONTRACTOR TO FIELD VERIFY EXISTING/PROPOSED STORM SEWER & UTILITIES FOR DEPTH& ALIGNMENT OF PROPOSED WATER MAIN. 5. BOTTOM OF STORM PIPE ELEVATIONS ARE SHOWN SO THE WATER MAIN CAN BE INSTALLED WITH 18 INCHES OF SEPARATION FROM THE PROPOSED STORM PIPE CROSSINGS. MJ REDUCER MA T C H L I N E - 24 + 5 0 " P R - R L 1 " 93 LD LD H H H H P P S T P P S T M O N M O N M O N P P S T P P S T P P S T T H H C C - T R C W M W V W V W V W V W V R B - 0 PZ Z Z PZ Z Z PZ Z Z PZ Z Z H H (b r i c k C V S ) (A u t o z o n e ) M O N H P P S T P P S T T W V P P S T P P S T P P S T P P S T LD H C W V T C PZZ Z PZ Z Z 24 " r c p 12" p v c t o 1 2 " c p p (verif i e d ) 12" vcp 6" ste e l 12 " v c p 30 " r c p 12" rcp 1 2 " r c p 8" cpp 24 " c p p 12" rcp 12 " c p p 12" rcp12" rcp12 " r c p 8" c p p 12 " r c p 36" rcp 1 2 " r c p 36" rcp 36" rcp 12 " r c p 36" rcp 36" rcp 12 " r c p 12 " r c p 18 " c p p 12" r c p 12" rc p 36" rcp 12 " r c p 12 " r c p 12" rc p 4" cp p M O N M O N M O N P P S T M O N M O N P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T P P S T (2 - s t y b r i c k ) conc. conc. c o n c . conc. conc. conc. conc. c o n c . conc. conc. conc. conc. conc. c o n c . conc. conc. c o n c . conc. conc. conc. conc. conc. conc. conc. c o n c . c o n c . c o n c . c o n c . c o n c . c o n c . c o n c . c o n c . gr a s s gr a s s grass grass gr a s s gr a s s gr a s s gr a s s grass gr a s s grass grassgrass grass grass grass grass grass grass grass grass grassgrass grass grass gr a s s gr a s s st o n e as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t as p h a l t rip r a p pla n t e r pla n t e r pla n t e r pla n t e r pla n t e r pl a n t e r pl a n t e r planter planter planter planter pla n t e r planter pla n t e r pla n t e r pla n t e r pla n t e r planter planter (T B M # 5 2 ) pla n t e r br i c k bri c k 30 " r c p 30 " r c p 836.0848344BRK 25 + 0 0 26 + 0 0 27 + 0 0 28 + 0 0 29 + 0 0 30 + 0 0 31 + 0 0 32 + 0 0 RANGELINE RD. ME D I C A L D R . RANGELINE RD.Line "PR-RL1" Temp. R / W Temp. R/W Temp. R/W Temp. R/W Temp. R/W Te m p . R / W R/W R/ W App. Exist. R/W App. Exist. R/W Ap p . E x i s t . R / W App. Exist. R/W KRG CENTRE LLC AUTOZONE INC KRG CENTRE LLC BARNES INVESTMENTII CO BARNES INVESTMENTII CO D & W HOLDINGS LLC EMMERT, PATRICIA RREVOCABLE LIVINGTRUST W/LE TOPATRICIA R EMMERT BFS RETAIL &COMMERCIALOPERATIONS LLCKRG CENTRE LLC W 425 LFT OF 12" HDPE SDR11 VIA HDD NEW 1" SERVICE LINE FORRELOCATED METER PIT RETIRE METER PIT RETIRE VALVE RETIRE HYDRANT ASSEMBLYAND VALVE 12"x12" MJ TEE (3) GATE VALVES (3) HARVEY ADAPTERS (3) WATER STOPS 174 LFT OF 12"HDPE SDR11 VIA HDD HARVEY ADAPTOR WATER STOP 45° MJ BEND 19 LFT OF 12" DI 12" CONNECTION45° MJ BEND 414 LFT OF 12"HDPE SDR11 VIA HDD RETIRE HYDRANT ASSEMBLY AND VALVE 12"x6" MJ TEE6" GATE VALVE 45° MJ BEND 12" GATE VALVE 12"x6" MJ REDUCER INSTALL FIRE HYDRANT ASSEMBLY 18 LFT OF 6" DI 45° MJ BENDHARVEY ADAPTERWATER STOP 6" CONNECTION RETIRE VALVE 6" ELECTRO FUSION SADDLE 6" GATE VALVE INSTALL HYDRANT ASSEMBLY D.B. 16-ENG-37 . RECOMMENDEDFOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALE CITY OF CARMEL D.B. J.C.B. D.B. . . VERTICAL SCALE 129 N/A 1"=30' DI R E C T O R Y P A T H : R : \ A c t i v e \ C a r m e l U t i l i t i e s \ C a r m e l B o n d P r o j e c t s \ R a n g e l i n e & 1 1 6 t h \ C A D \ 1 1 6 t h R a n g e l i n e D e s i g n FI L E N A M E : W a t e r p l a n s . d w g DA T E / U S E R : 5 / 1 2 / 2 0 2 1 4 : 1 8 P M / C b e n n e t t WPO N TE E. SINTE E T R IN E N G EE R A NDNILONA O EF ISSI A STATE OF 19700381 RGE DE RRT P R CROSSROAD ENGINEERS, P.C. WATER PLANS LINE "PR-RL1" NOTES:1)SURVEY INFORMATION WAS PROVIDED BY STRUCTURE POINT . CROSSROAD ENGINEERS ISRESPONSIBLE FOR THE WATER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANYDISCREPANCIES WITH THE SURVEY, PLEASE CONTACT STRUCTURE POINT AT (317) 547-5580.2)ROAD PLAN INFORMATION WAS PROVIDED BY STRUCTURE POINT. CROSSROAD ENGINEERS ISRESPONSIBLE FOR THE WATER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANYDISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT STRUCTURE POINT AT (317) 547-5580. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFYALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORTANY DISCREPANCIES TO THE WATER MAIN DESIGNER.4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCEWITH INDOT, CEG, OR CWU STANDARDS AND SPECIFICATIONS.5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITHROAD PROJECT IMPROVEMENTS. PROPOSED LEGEND PROPOSED WATER MAIN COMPLETE HYDRANT ASSEMBLY SHORT SIDE SERVICE GATE VALVE TEE MJ PLUG MJ CAP THRUST BLOCK SS 11.25° MJ BEND 22.5° MJ BEND 45° MJ BEND NOTES 1. CONTRACTOR TO FIELD VERIFY EXISTING WATER MAIN FOR SIZE,TYPE & LOCATION AT ALLCONNECTION & DISCONNECT LOCATIONS. 2. VALVE KEY EXTENSIONS ARE TO BE USED FOR ANY VALVE KEY BELOW 4' FROM FINISHED GRADE. 3. CONTRACTOR TO DEFLECT PIPE AND USE MJ BENDS AS NECESSARY OR AS DIRECTED BY C.W.U. PERSONNEL TO STAY ON PROPOSED ALIGNMENT AND AVOID EXISTING AND PROPOSED STRUCTURES, PIPES AND UTILITIES. 4. CONTRACTOR TO FIELD VERIFY EXISTING/PROPOSED STORM SEWER & UTILITIES FOR DEPTH& ALIGNMENT OF PROPOSED WATER MAIN. 5. BOTTOM OF STORM PIPE ELEVATIONS ARE SHOWN SO THE WATER MAIN CAN BE INSTALLED WITH 18 INCHES OF SEPARATION FROM THE PROPOSED STORM PIPE CROSSINGS. MJ REDUCER MA T C H L I N E - 24 + 5 0 " P R - R L 1 " 94 A/C A/C A/C A/C MON LD LDLD LD LD EM EM EM EME GM PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST MAG MAG MAG MON MON MON MON MON MON W WW W W W W W W W W W W W PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST RB-0 TT T H H H H H H H H H CC-TR C WV WV WV WV WV PPST PPST PPST PPST PPST PPST FFE PPST CC-TRT H WV C WV H T H MON EM FFE PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST PPST TT EM MON PPST PPST PPST PPST PPST PPST PPST RB-0 MAG MAG PZZZ H H H (flowers)(1-sty brick 18.1' tall) (gas pumps) (gas pumps) (gate) (b l o c k c a r w a s h ) (1-sty block gas station) 12" rcp 4" pvc 42 " r c p 12" rcp 1 2 " r c p 1 2 " c p p 12 " r c p 12" rcp 12" rcp 12 " r c p 8" p v c 8" pvc8" pvc30 " r c p 12" r c p 1 2 " c p p 12 " c p p 12" cpp 12 " r c p 12" r c p 12" rcp 12 " r c p 12 " r c p 12 " r c p 12 " r c p 4 2 " r c p 12" rcp 21" rcp 6" v c p 2" p v c 6" pv c 8" v c p 4" p v c 8" p v c 3" pv c 6" pv c 8" v c p 8" v c p 12" rcp 18" rcp 42 " r c p 12" rcp 42" rcp T conc. conc. conc. conc. c o n c . conc. c o n c . conc. c o n c . c o n c . conc. conc. conc. c o n c . c o n c . c o n c . conc. c o n c . conc . conc. c o n c . conc. conc. conc. conc. conc. conc. conc. conc. grass grass grass grass grass grass grass grass grass grass grass gr a s s gr a s s gr a s s gr a s s gr a s s grass grass grass grass grass grass grass grass grass grass stone as p h a l t asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt asphalt as p h a l t riprap planter pl a n t e r pla n t e r pl a n t e r planter planter planter planter planter planter planter (TBM#50) c o n c . mulch riprap 48 " r c p 3" pvc - forcemain 3" p v c - f o r c e m a i n WV 116TH ST. Line "PR-RL1" Te m p . R / W App. Exist. R/W R/W R/W Temp. R/W Te m p . R / W T e m p . R / W Te m p . R / W R/ W R / W Ap p . E x i s t . R / W CORNER ASSOCIATESLP KRG CENTRE LLC S MART REAL ESTATEINC SPEEDWAY LLC WOODLAND SHOPPESA PARTNERSHIPLAZEROV I S &FRANCES COYOTE ENTERPRISESLLC LA MOUCHE LLC BROWN, CHARLES M &KAREN C TE KRG CENTRE LLC FAIRGREEN TRACEHOMEOWNERSASSOCIATION INC CORNER ASSOCIATESLP CARMEL CLAY PARKSBUILDINGCORPORATION 16 + 0 0 17 + 0 0 18 + 0 0 19 + 0 0 20 + 0 0 21 + 0 0 22 + 0 0 23 + 0 0 24 + 0 0 Line "PR-S1A" RA N G E L I N E R D . 116TH ST. 295 LFT OF 12" HDPE SDR11 VIA HDD RETIRE VALVE RETIRE HYDRANT ASSEMBLYAND VALVE 45° MJ BEND ADJUST VALVE TO GRADE MJ HARVEY ADAPTERWATER STOP 12"x12" MJ TEE(2) GATE VALVES 11 LFT OF12" DI 12"x12" MJ TEE (2) GATE VALVES MJ HARVEY ADAPTERWATER STOP 243 LFT OF 12" HDPE SDR11 VIA HDD MJ HARVEY ADAPTER WATER STOP 45° MJ BEND 14 LFT OF 12" DI 12" CONNECTION45° MJ BEND MJ HARVEY ADAPTERWATER STOP 100 LFT OF 12" HDPE SDR11 VIA HDD 6" ELECTRO FUSION SADDLE 6" GATE VALVE INSTALL NEWHYDRANT ASSEMBLY 50 LFT OF 6" RESTRAINED JOINT DI RETIRE VALVE PLUG AT TEE ADJUST VALVE TO GRADE 12" CONNECTION ADJUST VALVES TO GRADE RETIRE FIRE HYDRANT INSTALL NEW HYDRANT ASSEMBLY 59 LFT OF 12" DI 45° MJ BEND D.B. 16-ENG-37 . RECOMMENDEDFOR APPROVAL DESIGN ENGINEER DATE DESIGNED: CHECKED: DRAWN: CHECKED: SURVEY BOOK CONTRACT DESIGNATION SHEETS of PROJECT BRIDGE FILEHORIZONTAL SCALE CITY OF CARMEL D.B. J.C.B. D.B. . . VERTICAL SCALE 129 N/A 1"=30' DI R E C T O R Y P A T H : R : \ A c t i v e \ C a r m e l U t i l i t i e s \ C a r m e l B o n d P r o j e c t s \ R a n g e l i n e & 1 1 6 t h \ C A D \ 1 1 6 t h R a n g e l i n e D e s i g n FI L E N A M E : W a t e r p l a n s 2 . d w g DA T E / U S E R : 5 / 1 2 / 2 0 2 1 4 : 4 8 P M / C b e n n e t t WPO N TE E. SINTE E T R IN E N G EE R A NDNILONA O EF ISSI A STATE OF 19700381 RGE DE RRT P R CROSSROAD ENGINEERS, P.C. WATER PLANS LINE "PR-S1A" PROPOSED LEGEND PROPOSED WATER MAIN COMPLETE HYDRANT ASSEMBLY SHORT SIDE SERVICE GATE VALVE TEE MJ PLUG MJ CAP THRUST BLOCK SS 11.25° MJ BEND 22.5° MJ BEND 45° MJ BEND NOTES 1. CONTRACTOR TO FIELD VERIFY EXISTING WATER MAIN FOR SIZE,TYPE & LOCATION AT ALLCONNECTION & DISCONNECT LOCATIONS. 2. VALVE KEY EXTENSIONS ARE TO BE USED FOR ANY VALVE KEY BELOW 4' FROM FINISHED GRADE. 3. CONTRACTOR TO DEFLECT PIPE AND USE MJ BENDS AS NECESSARY OR AS DIRECTED BY C.W.U. PERSONNEL TO STAY ON PROPOSED ALIGNMENT AND AVOID EXISTING AND PROPOSED STRUCTURES, PIPES AND UTILITIES. 4. CONTRACTOR TO FIELD VERIFY EXISTING/PROPOSED STORM SEWER & UTILITIES FOR DEPTH& ALIGNMENT OF PROPOSED WATER MAIN. 5. BOTTOM OF STORM PIPE ELEVATIONS ARE SHOWN SO THE WATER MAIN CAN BE INSTALLED WITH 18 INCHES OF SEPARATION FROM THE PROPOSED STORM PIPE CROSSINGS. MJ REDUCER 95 NOTES:1)SURVEY INFORMATION WAS PROVIDED BY STRUCTURE POINT . CROSSROAD ENGINEERS ISRESPONSIBLE FOR THE WATER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANYDISCREPANCIES WITH THE SURVEY, PLEASE CONTACT STRUCTURE POINT AT (317) 547-5580.2)ROAD PLAN INFORMATION WAS PROVIDED BY STRUCTURE POINT. CROSSROAD ENGINEERS ISRESPONSIBLE FOR THE WATER INSTALLATION PORTION OF THESE PLANS ONLY. IF THERE ARE ANYDISCREPANCIES WITH THE ROAD PLANS, PLEASE CONTACT STRUCTURE POINT AT (317) 547-5580. 3) UTILITIES SHOWN PER FIELD SURVEY (SEE NOTE 1). THE CONTRACTOR SHALL EXPOSE AND VERIFYALL WATER UTILITY CONNECTIONS AND CROSSINGS PRIOR TO ANY CONSTRUCTION, AND REPORTANY DISCREPANCIES TO THE WATER MAIN DESIGNER.4) ANY EXISTING WATER FACILITIES TO BE RETIRED OR REMOVED SHALL BE DONE SO IN ACCORDANCEWITH INDOT, CEG, OR CWU STANDARDS AND SPECIFICATIONS.5) CONTRACTOR TO VERIFY ELEVATIONS OF WATER MAIN RELOCATIONS, SO NOT TO CONFLICT WITHROAD PROJECT IMPROVEMENTS. 810 820 830 Ac = 1.6 Af = 40.5 Vc = 0 Vf = 0 810 820 830 Ac = 1.6 Af = 21.7 Vc = 3 Vf = 58 810 820 830 Ac = 1.8 Af = 13.5 Vc = 3 Vf = 33 R/W 104 00 Ex. R/W Ex. R/W 104+00.00 "PR-RL1" BEGIN PROJECT Temp. R/W 104 50 Ex. R/W Ex. R/W Temp. R/W 105 00 Ex. R/W Ex. R/W Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 96 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:25 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 810 820 830 Ac = 2.0 Af = 9.5 Vc = 4 Vf = 21 810 820 830 Ac = 3.1 Af = 30.1 Vc = 5 Vf = 37 810 820 830 L=26'-0" Class III Drive Req'd. 11'-0" 6.5% Temp. R/W Ex. R/W 105 16.44 1.5% 105 50 Ex. R/W Ex. R/W Temp. R/W 106 00 Ex. R/W Ex. R/W 8 1 8 .6 P .G. 8 1 8 . 7 0 8 1 8 . 7 0 P .G. 8 1 8 .6 105+80.0 Str. No. 302 Inv. = 809.64 Str. No. 303 105+80.0 Inv. = 814.03 Inv. = 814.00 Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 97 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:26 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 810 820 830 Ac = 7.2 Af = 65.1 Vc = 10 Vf = 88 820 830 Ac = 24.3 Af = 124.1 Vc = 29 Vf = 175 L=12'-4" Class III Drive Req'd. 1.3% Ex. R/W Temp. R/W 8 1 8 .6 P .G. 8 1 8 . 9 0 106 27.55 106 50 Ex. R/W Ex. R/W Inv. = 809.91 8 1 8 .7 P.G . 8 1 9 .0 5 8 1 8 .7 P.G . 8 1 9 .0 5 R/W Str. No. 304 106+48.3 Ex. BldgEx. Bldg Ex. Bldg Temp. R/W Inv. = 815.00Inv. = 815.63 106+45.0 Str. No. 303A 107 00 Ex. R/W Ex. R/WR/W 106+86.0 106+79.0 Inv. = 815.50 8 1 8 . 7 P . G . 8 1 9 . 4 0 P.G . 8 1 9 .4 0 81 8 .9Str. No. 306 Str. No. 305 Inv. = 815.15 Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 98 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:27 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 Ac = 24.8 Af = 125.0 Vc = 4 Vf = 22 820 830 Ac = 20.6 Af = 203.5 Vc = 38 Vf = 275 810 820 830 Ac = 0.0 Af = 323.7 Vc = 19 Vf = 488 107 04.86 Ex. R/W Ex. R/WR/W P .G. 8 1 9 . 4 3 8 1 8 .8 Temp. R/W 107 50 Ex. R/W Ex. R/W"PR-S1A" MATCH LINE "PR-S1A" MATCH LINE 108 00 "PR-S1A" MATCH LINE "PR-S1A" MATCH LINE LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 99 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:28 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 Ac = 10.3 Af = 45.9 Vc = 10 Vf = 342 820 830 Ac = 16.0 Af = 25.9 Vc = 3 Vf = 9 810 820 830 840 Ac = 26.3 Af = 24.8 Vc = 34 Vf = 40 108 50 Ex. R/W "PR-S1A" MATCH LINE "PR-S1A" MATCH LINE 108 Ex. R/W "PR-S1A" MATCH LINE "PR-S1A" MATCH LINE 56.87 Ex. 109 00 Ex. R/W Ex. R/W R/W 8 2 0 .0 P . G . 8 2 0 .0 0 8 2 0 . 0 0 P .G. 8 1 9 . 9 108+80.0 Str. No. 310 Inv. = 815.73 108+98.0 Str. No. 312 Inv. = 815.68Inv. = 815.50 Inv. = 815.50 Ex. Bldg 108+73.1 Str. No. 309 Temp. R/W Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 100 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:28 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 840 820 830 840 Ac = 4.1 Af = 26.7 Vc = 28 Vf = 48 820 830 840 Ac = 2.5 Af = 30.9 Vc = 6 Vf = 53 109 Ex.Ex. R/W 26.606.5%1.5% 8'-0"6'-0" 4.8% Temp. R/W R/W L=18'-6" Mod. Class III Drive Req'd. Ex. 109 50 Ex. R/W Ex. R/W 8 2 0 .3 P .G. 8 2 0 . 2 2 P .G. 8 2 0 .38 2 0 . 2 2 Ex. Bldg Temp. R/W R/WTemp. R/W Ex. 109 99 Ex. R/W Ex. R/W 0.5% 8'-0"6'-0" 6.5% Ex. Bldg Temp. R/W R/W 5.4% L=18'-6" Mod. Class III Drive Req'd. Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 101 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:34 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 840 Ac = 12.5 Af = 33.6 Vc = 14 Vf = 60 820 830 840 820 830 840 Ex. 110 50 Ex. R/W Ex. R/W R/W Temp. R/W 1.5% 110 91.1 8'-0"5'-0" 6.5%2.8% Ex. R/W Mod. Class III Drive Req'd. L=16'-10" Temp. R/W 6'-0"10'-0" L=26'-2" Class III Drive Req'd. 1.5%9.5% 110 93.36.5% 14% Ex. R/W 8'-0" R/W Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 102 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:35 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 840 Ac = 3.7 Af = 41.0 Vc = 15 Vf = 69 820 830 840 Ac = 18.4 Af = 33.6 Vc = 20 Vf = 69 111 00 Ex. R/W Ex. R/W R/W Temp. R/W Temp. R/W 111 50 Ex. R/W Ex. R/W Temp. R/WTemp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 103 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:36 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 840 Ac = 17.9 Af = 33.0 Vc = 12 Vf = 22 820 830 840 Ac = 16.7 Af = 28.1 Vc = 20 Vf = 36 111 68.11 Ex. R/W Temp. R/WTemp. R/W Ex. R/W 112 00 Ex. R/W Ex. Bldg Temp. R/WTemp. R/W Ex. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 104 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:37 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 840 Ac = 15.2 Af = 20.3 Vc = 30 Vf = 45 820 830 840 810 820 830 840 Ac = 15.6 Af = 12.4 Vc = 29 Vf = 30 112 50 Ex. R/W Ex. R/W Temp. R/WTemp. R/W 6'-10" L=26'-2" Class III Drive Req'd. 6'-0" 1.5%6.5% 8'-0" 6.5% Ex. R/W 112 64.4 Temp. R/W 113 00 Ex. R/W Ex. R/W Ex. Bldg Temp. R/WTemp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 105 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:37 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 810 820 830 840 Ac = 19.3 Af = 10.6 Vc = 32 Vf = 21 810 820 830 840 Ac = 54.0 Af = 25.7 Vc = 68 Vf = 34 820 830 840 Ac = 45.2 Af = 23.1 Vc = 21 Vf = 10 113 50 Ex. R/W Ex. R/W Ex. Bldg Temp. R/W Temp. R/W 114 00 Ex. R/W Ex. R/W Inv. = 821.05 114+01.0 Str. No. 504 Inv. = 821.00Ex. Inv. = 818.34 114+01.0 Str. No. 503 113+93.0 Str. No. 501 Inv. = 821.20 Inv. = 821.00 Temp. R/WTemp. R/W R/W "PR-S2A" Match Line Temp. R/W R/W R/W "PR-S2A" Match LineEx. R/W 114 11.4 LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 106 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:38 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 810 820 830 840 Ac = 22.9 Af = 34.7 Vc = 49 Vf = 41 830 840 Ac = 22.4 Af = 28.8 Vc = 42 Vf = 59 Ac = 19.9 Af = 34.1 Vc = 8 Vf = 12 114 50 Ex. R/W "PR-S2A" Match Line "PR-S2A" Match Line 115 00 Ex. R/W "PR-S2A" Match Line "PR-S2A" Match Line "PR-S2A" Match Line "PR-S2A" Match Line 115 10.4 LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 107 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:39 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 840 Ac = 12.7 Af = 11.7 Vc = 24 Vf = 34 830 840 Ac = 9.9 Af = 11.9 Vc = 21 Vf = 22 830 840 850 Ac = 8.5 Af = 16.5 Vc = 17 Vf = 26 115 50 Ex. R/W Ex. R/W 115+60.0 Str. No. 511 Inv. = 825.00 Ex. Inv. = 822.32 115+60.0 Str. No. 510 Inv. = 824.97 Inv. = 825.50 115+62.0 Str. No. 512 Inv. = 825.30 Ex. Bldg Temp. R/W 116 00 Ex. R/W Ex. Bldg Ex. R/W Temp. R/W 116 50 Ex. R/W Ex. R/W Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 108 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:40 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 830 840 850 Ac = 9.1 Af = 13.3 Vc = 16 Vf = 28 830 840 850 830 840 850 Ac = 10.6 Af = 18.4 Vc = 18 Vf = 29 117 00 Ex. R/W Ex. R/W Temp. R/W Temp. R/W 8'-0"10'-0" 1.5% 10.5% 9.5%117 22.6 L=34'-4" Class III Drive Req'd. 0.5% 6'-0" Ex. R/W Temp. R/W 117 50 Ex. R/W Ex. R/WEx. Bldg Temp. R/W Temp. R/W -1.5%-1.5% LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 109 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:40 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 830 840 850 830 840 850 Ac = 20.7 Af = 14.7 Vc = 29 Vf = 31 830 840 850 Ac = 9.7 Af = 11.8 Vc = 28 Vf = 25 6'-0" 1.5% 117 81.6 8'-0" 9.5% L=31'-1" Class III Drive Req'd. 6.5% Ex. R/W Temp. R/W Ex. Bldg 118 00 Ex. R/W Ex. R/W Temp. R/W Inv. = 834.30 Ex. Inv. = 829.70 Str. No. 517 Inv. = 834.50 Str. No. 516 Temp. R/W -1.5%7:1 118 50 Ex. R/W Ex. R/W Temp. R/W Inv. = 832.52 Str. No. 318A 118+71.0118+70.9 Str. No. 318 Inv. = 832.36 Exist. 12" RCP Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 110 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:41 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 840 850 860 Ac = 6.8 Af = 17.7 Vc = 15 Vf = 27 840 850 8'-0"6'-0" 1.5%6.8% 118 61.10.5% Ex. R/W L=27'-5" Mod. Class III Drive Req'd. Temp. R/W 119 00 Ex. R/W Ex. R/W Temp. R/W 6'-0"8'-0" Ex. R/W 1.5% 119 02.06.5% L=19'-0" Class III Drive Req'd. 3.5% LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 111 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:42 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 860 Ac = 23.3 Af = 11.7 Vc = 28 Vf = 27 850 860 840 850 860 Ac = 9.0 Af = 12.4 Vc = 30 Vf = 22 119 50 Ex. R/W Ex. R/W Ex. Bldg Temp. R/W Ex. R/W 0.7% 119 97.7 L=19'-0" Mod. Class III Drive Req'd. 120 00 Ex. R/W Ex. R/W Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 112 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:43 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 860 840 850 860 Ac = 15.1 Af = 15.2 Vc = 22 Vf = 26 8'-0"6'-0" Ex. R/W 1.5%9.5% 120 44.6 6.5% Temp. R/W L=21'-5" Mod. Class III Drive Req'd. 120 50 Ex. R/W Ex. R/W Temp. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 113 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:43 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 860 Ac = 16.6 Af = 14.1 Vc = 29 Vf = 27 840 850 860 121 00 Ex. R/W Temp. R/W Ex. R/W Ex. R/W 121 03.5 6'-0" 6.5% 11'-1" Temp. R/W 1.5% L=17'-2" Mod. Class III Drive Req'd. LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 114 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:44 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 860 Ac = 10.2 Af = 22.7 Vc = 25 Vf = 34 850 860 840 850 860 Ac = 16.7 Af = 13.6 Vc = 25 Vf = 34 121 50 Ex. R/W Inv.= 841.12 Str. No. 323 Temp. R/W Temp. R/W Ex. R/W 6'-0"8'-0" 1.5%9.5%6.5% 121 61.1 Temp. R/W L=22'-1" Mod. Class III Drive Req'd. Ex. R/W 122 00 Ex. R/W 122+12.93 "PR-RL1" INCIDENTAL CONSTRUCTION END PROJECT & BEGIN Ex. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 115 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:45 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 860 840 850 860 Ac = 16.7 Af = 11.2 Vc = 31 Vf = 23 Ex. R/W 1.7%6.5% 8'-0"5'-0" 122 21.74'-4" L=17'-4" Mod. Class III Drive Req'd. 1.5% Ex. R/WEx. R/W 122 50.0 LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 116 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:46 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 860 840 850 860 Ac = 14.1 Af = 6.2 Vc = 29 Vf = 16 8'-0" 6.5%2.3% 3'-7" Ex. R/W 122 90.53'-0" L=14'-7" Mod. Class III Drive Req'd. 1.5% Ex. R/W 123 00.0 Ex. R/W LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 117 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:46 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 860 850 860 840 850 860 Ac = 16.7 Af = 5.5 Vc = 29 Vf = 11 10'-6" 6.5%1.5% Ex. R/W L=13'-6" Class III Drive Req'd. 123 43.73'-0" 8'-0" 6.5%1.5% 5.7% 6'-5" Ex. R/W 123 48.3 L=17'-4" Mod. Class III Drive Req'd. Ex. R/W Ex. R/W 123 50.0 LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 118 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:47 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 860 Ac = 10.4 Af = 3.3 Vc = 25 Vf = 8 840 850 860 Ex. R/W Ex. R/W 124 00.0 8'-0" 6.5%1.5%8.5% Ex. R/W 7'-6" 124 19.13'-2" L=18'-8" Mod. Class III Drive Req'd. LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 119 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:48 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 840 850 860 Ac = 12.7 Af = 2.7 Vc = 21 Vf = 6 Ex. R/W Ex. R/W 124 50.0 LINE "PR-RL1" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 120 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PR-RL1.01.dgn5/24/2021 09:47:48 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 820 830 820 830 820 830 Vc = 0 Vf = 0 Vc = 9 Vf = 2 Af = 20.1 Ac = 11.2 Af = 3.2 Ac = 13.7 Af = 2.5 Ac = 10.5 Vc = 22 Vf = 21 32 80 Ex. Bldg Ex. R/W Ex. R/W 32+80.00 "PR-S1A" BEGIN CONSTRUCTION 33 00 Ex. R/W Ex. R/W 33 50 R/W Ex. R/W Ex. R/W Ex. R/W L=11'-9" Class III Drive Req'd. 1.5% R/W 33 10.20 LINE "PR-S1A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 121 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PRS1A.01.dgn5/24/2021 09:47:49 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 820 830 820 830 Ac = 9.8 Af = 25.1 Af = 27.9 Vc = 19 Vf = 42 Ac = 23.4 Vc = 31 Vf = 49 33 83.30 Ex. R/W 1.5%3.6% 26'-9"8'-0"6'-0" 0.3% L=40'-9" Mod. Class III Drive Req'd. 34 00 R/WEx. R/W Ex. R/W Temp. R/W 8 1 9 . 2 P .G. 8 1 9 . 4 1 34 50 Ex. Bldg Ex. BldgR/WEx. R/W Ex. R/W 8 1 9 . 4 1 P .G. 8 1 9 . 2 34+74.0 Str. No. 345 Inv. = 814.25 Str. No. 344 34+73.0 Inv. = 813.70 Temp. R/W LINE "PR-S1A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 122 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PRS1A.01.dgn5/24/2021 09:47:50 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 810 820 830 820 830 820 830 Af = 61.1 Af = 122.2 Ac = 4.8 Af = 194.7 Ac = 31.4 Vc = 51 Vf = 82 Ac = 28.8 Vc = 33 Vf = 101 Vc = 95 Vf = 899 8 1 8 . 9 P . G. 8 1 9 . 4 0 35 00 Ex. Bldg R/WEx. R/W Ex. R/W 8 1 8 . 9 P . G. 8 1 9 . 4 0 35+11.0 Str. No. 348 Inv. = 812.15 Temp. R/W Inv. = 814.20 34+80.0 Str. No. 346 Inv. = 813.95 35+17.5 Str. No. 348A Inv. = 813.75 35 29.87 Ex. Bldg R/WEx. R/W Ex. R/W 8 1 9 .6 0 P. G . 8 1 8 .6 Temp. R/W 36 83.04 Ex. R/W Ex. R/W Ex. R/WTemp. R/W LINE "PR-S1A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 123 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PRS1A.01.dgn5/24/2021 09:47:50 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 810 820 830 820 830 820 830 Ac = 5.3 Af = 184.8 Vc = 3 Ac = 5.7 Af = 135.5 Vf = 119 Vc = 10 Vf = 297 8 1 7 .3 P .G. 8 1 9 . 1 0 37 00 Ex. R/W Ex. Bldg Ex. R/W Ex. R/W P .G. 8 1 9 . 1 0 8 1 7 .3 Inv. = 815.20 Str. No. 349 37+03.0 Inv. = 814.53 Str. No. 350 37+06.0 37+09.0 Str. No. 351 Inv. = 814.50 Temp. R/W 81 6 .9 P.G . 8 1 8 .2 4 37 50 Ex. R/W Ex. R/W Ex. R/W P .G. 8 1 6 .98 1 8 . 2 4 Temp. R/W 37 95.40 Ex. R/W Ex. R/W 1.5% 22'-3"8'-2"6'-0" 8.0%6.5%P. G . 8 1 7 .18 1 7 .8 9 L=36'-5" Mod. Class III Drive Req'd. Temp. R/W LINE "PR-S1A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 124 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PRS1A.01.dgn5/24/2021 09:47:50 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 810 820 830 810 820 830 820 830 Ac = 4.0 Af = 54.4 Vc = 9 Ac = 1.5 Af = 55.5 Vc = 5 Ac = 1.2 Vc = 3 Vf = 176 Vf = 102 Af = 2.2 Vf = 53 820 810 8 1 7 . 1 P . G . 8 1 7 . 8 8 38 00 Ex. R/W Ex.R/W Ex. R/W Ex. R/W P . G . 8 1 7 . 18 1 7 . 8 8 Inv. = 812.60 Str. No. 355 38+07.0 Inv. = 812.66 Str. No. 354 38+07.0 Temp. R/W 8 1 7 .7 P . G . 8 1 8 .0 3 38 50 Ex. R/W Ex. R/W Ex. R/W 8 1 7 .7 P . G . 8 1 8 .0 3 Exist. 48" RCP Inv. = 812.85 Str. No. 358 38+47.0 39 00 Ex. R/W Ex. R/W L=13'-0" Class III Drive Req'd. 1.5% 38 52.53 Ex. R/W LINE "PR-S1A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 125 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PRS1A.01.dgn5/24/2021 09:47:51 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 820 830 820 830 820 830 Ac = 0.7 Vc = 2 Vf = 3 Ac = 1.3 Vc = 0 Vf = 0 Af = 0.9 Af = 0.4 39 10.70 Ex. R/W 0.2% L=19'-4" Mod. Class III Drive Req'd. 39 50 Ex. R/W Ex. R/W 39 55 Ex. R/W Ex. R/W 39+55.00 "PR-S1A" END CONSTRUCTION LINE "PR-S1A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 126 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PRS1A.01.dgn5/24/2021 09:47:51 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 830 830 830 830 840 Ac = 5.0 Vc = 0 Vf = 0 Ac = 5.0 Vc = 2 Vf = 1 Ac = 6.8 Af = 45.0 Af = 61.3 Af = 4.4 Af = 3.5 Vc = 11 Vf = 45 Ac = 48.4 Vc = 26 Vf = 51 10 90 10+90.00 "PR-S2A" BEGIN CONSTRUCTION Temp. R/WTemp. R/W 11 00 Temp. R/WTemp. R/W 11 50 11+35.0 Str. No. 518 Inv. = 822.90 Inv. = 823.00 11+36.0 Str. No. 519 R/W Temp. R/WTemp. R/W R/W 11 75.69 Ex. R/W Temp. R/WR/W LINE "PR-S2A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 127 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PRS2A.01.dgn5/24/2021 09:47:52 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 830 840 830 840 830 840 Af = 85.7 Af = 92.7 Ac = 21.0 Vc = 129 Vf = 272 Ac = 16.5 Vc = 17 Vf = 80 Ac = 13.2 Af = 5.8 Vc = 28 Vf = 91 12 75.69 Ex. R/W Temp. R/W R/W Ex. R/W 13 00 Ex. Bldg Inv. = 823.00 12+90.0 Str. No. 521 Temp. R/W R/W R/W Ex. R/W Ex. R/W 13 50 Ex. Bldg Temp. R/W R/W Ex. R/W Ex. R/W LINE "PR-S2A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 128 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PRS2A.01.dgn5/24/2021 09:47:52 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129 830 840 830 840 Vf = 8 Ac = 5.3 Vc = 2 Vf = 0 Ac = 12.3 Af = 3.3 Vc = 24 Af = 0.6 14 00 Ex. Bldg Ex. BldgTemp. R/W R/W Ex. R/WEx. R/W 14 06 14+06.00 "PR-S2A" END CONSTRUCTION Ex. Bldg Ex. Bldg Temp. R/W R/W Ex. R/W Ex. R/W LINE "PR-S2A" BRIDGE FILE DESIGNATION CONTRACT SURVEY BOOK CHECKED: DESIGNED:DRAWN: CHECKED: HORIZONTAL SCALE VERTICAL SCALE PROJECT of SHEETS 129 160 160 P:\2015\02101\D. Drawings\02 - 116th & Rangeline RAB\201502101.RD.CS.PRS2A.01.dgn5/24/2021 09:47:52 AMjhofman 40 30 0 2010 130 120140 20150 9080 100 1201104030507060 110 8070 90 110100302040605070608010090 130120 14050 150 1301009080110130120 150140507060 CUT 40 FILL Scale: 1 inch = 10 feet CROSS SECTIONS 150 140 103020 Ind ia n a_ Sh a de.t b l Ind y -Pdf.p lt cfg CITY OF CARMEL 16-ENG-37 1" = 10'-0" 1" = 10'-0" CROSS SECTIONSTJMTJM NRM NRM 129