Loading...
HomeMy WebLinkAboutC500 - Overall Utility Plan - SU1.0TBM#1 = 813.74 TBM#2 = 809.81 TBM#3 = 803.80 CO M M O N A R E A " N " COMMON AREA "L" KE Y S T O N E A V E N U E / S . R . 4 3 1 K E Y S T O N E A V E N U E / S . R . 4 3 1 K E Y S T O N E A V E N U E / S . R . 4 3 1 SMOKY ROW ROAD / E 136TH STREET FDC FDC FDC FDC FDC FDC P R O P E R T Y L I N E P R O P E R T Y L I N E PROPERTY LINE PROPERTY LINE 80' EXISTING EMERGENCY SPILLWAY ATS SLDP ATS UP UP UP UP UP UP UP VE S T I B U L E B1 0 7 FI L M B1 0 8 EQ U I P . S T O R A G E B1 1 2 IC E R O O M B1 2 2 CL A S S R O O M B1 0 9 TA B L E S T O R A G E B1 2 6 ME E T I N G A R E A B1 0 1 HA L L W A Y A1 3 7 TR A I N I N G A1 2 9 VE S T I B U L E A1 2 7 FIR E P U M P A1 2 5 WO M E N ' S OF F I C I A L S / MA N A G E R S A1 2 6 CL A S S R O O M A1 2 2 CO R R I D O R A1 2 8 OF F I C E A1 3 8 IT / D A T A C L O S E T A1 3 5 EQ U I P M E N T A1 0 1 HA L L W A Y A1 0 5 CL A S S R O O M A1 0 6 CO A C H E S O F F I C E A1 0 7 LO C K E R S A1 0 9 BA T H R O O M A1 0 8 BA T H R O O M A1 1 2 SH O W E R S A1 1 3 EQ U I P M E N T A1 0 2 LA U N D R Y A1 0 3 LO C K E R R O O M A1 1 0 OF F I C E A1 1 7 VE S T I B U L E A1 1 1 WO M E N S / OF F I C I A L S A1 2 0 EL E C T R I C A L A1 1 4 CL I N I C A1 3 0 EL E V . E Q P T . A1 3 4 RE C O V E R Y A1 3 1 BA T H R O O M A1 3 9 BA T H R O O M A1 4 0 ST O . A1 2 1 CH A N G I N G R O O M A1 1 5 CO A C H E S A1 2 4 CO R R I D O R / HA L L W A Y A1 2 3 CO A C H E S ' LO C K E R B1 1 8 HE A D C O A C H OF F I C E B1 1 9 ?? WO M E N S / OF F I C I A L S BA T H R O O M A1 1 9 ST O R A G E B1 2 0 VE S T I B U L E B1 2 1 BA T H R O O M B1 1 6 CU S T O D I A L B1 2 3 SH O W E R S B1 1 5 HA L L W A Y B1 2 5 LO C K E R R O O M B1 1 4 ME C H A N I C A L B1 1 3 BA T H R O O M B1 1 0 BA T H R O O M B1 1 1 PA S S A G E B1 2 4 ME C H A N I C A L B1 0 2 UP ST-401-EX ST-400 ST-CO-2 ST-CO-1 ST-102 ST-103 ST-104-EX ST-202 ST-300 ST-301-EX ST-201 ST-203-EX ST-104-EX NEW STWQ BMP W-1 PR O P E R T Y L I N E EXISTING DRY DETENTION BASIN EXISTING CONDITIONS DEVELOPED CONDITIONS TOTAL CONTRIBUTING AREA BOTTOM OF POND ELEVATION TOP OF BANK ELEVATION 10 YEAR ELEVATION 10 YEAR RELEASE RATE 10 YEAR STORAGE VOLUME 100 YEAR ELEVATION 100 YEAR RELEASE RATE 100 YEAR STORAGE VOLUME 45.26 ac. 797.83 804.65 801.50 4.49 cfs 4.65 ac./ft. 802.65 12.65 cfs 9.91 ac./ft. 45.26 ac. 797.83 ST-TD1 ST-200 100% CONSTRUCTION DOCUMENTS COPYRIGHT 2024 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT KEY PLAN BUILDING "A" BUILDING "B" A B SOUTH SUPPORT BUILDING GREYHOUND ACTIVITIES CENTER 5201 E Main Street, Carmel, IN 46033 317-844-9961 PROJECT NUMBER: 222154.00 PROJECT ISSUE DATE: 7.26.2024 DRAWN BY: ARS 317.848.0966 350 E NEW YORK ST. SUITE 300, INDIANAPOLIS IN 46204 PROJECT MANAGER: PMR 222154.00 CARMEL HIGH SCHOOL STADIUM GRANDSTAND RENOVATION PROJECT CARMEL CLAY SCHOOLS 2390 E. SMOKY ROW (HOME SIDE) 2450 E. SMOKY ROW (VISITOR SIDE) CARMEL, IN 46032 PLAN NORTH REV. NO.DESCRIPTION DATE 19700317 No. CITY SUBMITTAL 08-14-20241 50 150050100 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's below. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! SU1.0 OVERALL UTILITY PLAN SEE DWG SU1.1 UTILITY PLAN - HOME GRANDSTAND SEE DWG SU1.2 UTILITY PLAN - VISITOR GRANDSTAND HOME GRANDSTAND EXPANSION 1.SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2.TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY CEC CIVIL & ENVIRONMENTAL CONSULTANTS DATED MAY 17, 2022. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3.CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4.SEE SHEET SU1.1 FOR NEW STORM LATERALS. 5.SEE SHEET SU1.2 FOR NEW SANITARY SEWER LATERAL, FIRE PROTECTION, DOMESTIC WATER, GAS, ELECTRICAL/POWER AND TELECOMMUNICATION INFORMATION. GENERAL NOTES PROPOSED CHILLED WATER LINE PROPOSED COMMUNICATION LINE PROPOSED ELECTRICAL LINE PROPOSED OVERHEAD ELECTRICAL LINE PROPOSED UNDERGROUND ELECTRICAL LINE PROPOSED FIBER OPTIC LINE PROPOSED FIRE PROTECTION LINE PROPOSED SANITARY FORCE MAIN PROPOSED GAS LINE PROPOSED SANITARY SEWER LINE PROPOSED STEAM LINE PROPOSED STORM SEWER LINE PROPOSED DOWNSPOUT LINE PROPOSED TELEPHONE LINE PROPOSED WATER LINE PROPOSED FIRE HYDRANT PROPOSED FIRE DEPARTMENT CONNECTION PROPOSED STORM INLET PROPOSED STORM MANHOLE PROPOSED LIGHT POLE UTILITY LEGEND APPROXIMATE LIMITS OF CONSTRUCTION SEE DWG SU1.1 UTILITY PLAN - HOME STANDS VISITOR GRANDSTAND TAC COMMENTS 10-14-20242 TP TP TP TREE PROTECTION - PER DETAIL F/L1.2 TP TP TP TP TP TP TP TP TP TP TP TP TP TP TP TPTP TP TP TP TP TP