HomeMy WebLinkAboutC500 - Overall Utility Plan - SU1.0TBM#1 = 813.74
TBM#2 = 809.81
TBM#3 = 803.80
CO
M
M
O
N
A
R
E
A
"
N
"
COMMON AREA "L"
KE
Y
S
T
O
N
E
A
V
E
N
U
E
/
S
.
R
.
4
3
1
K
E
Y
S
T
O
N
E
A
V
E
N
U
E
/
S
.
R
.
4
3
1
K
E
Y
S
T
O
N
E
A
V
E
N
U
E
/
S
.
R
.
4
3
1
SMOKY ROW ROAD / E 136TH STREET
FDC
FDC
FDC
FDC
FDC
FDC
P
R
O
P
E
R
T
Y
L
I
N
E
P
R
O
P
E
R
T
Y
L
I
N
E
PROPERTY LINE
PROPERTY LINE
80' EXISTING EMERGENCY
SPILLWAY
ATS
SLDP
ATS
UP
UP
UP
UP
UP
UP
UP
VE
S
T
I
B
U
L
E
B1
0
7
FI
L
M
B1
0
8
EQ
U
I
P
.
S
T
O
R
A
G
E
B1
1
2
IC
E
R
O
O
M
B1
2
2
CL
A
S
S
R
O
O
M
B1
0
9
TA
B
L
E
S
T
O
R
A
G
E
B1
2
6
ME
E
T
I
N
G
A
R
E
A
B1
0
1
HA
L
L
W
A
Y
A1
3
7
TR
A
I
N
I
N
G
A1
2
9
VE
S
T
I
B
U
L
E
A1
2
7
FIR
E
P
U
M
P
A1
2
5
WO
M
E
N
'
S
OF
F
I
C
I
A
L
S
/
MA
N
A
G
E
R
S
A1
2
6
CL
A
S
S
R
O
O
M
A1
2
2
CO
R
R
I
D
O
R
A1
2
8
OF
F
I
C
E
A1
3
8
IT
/
D
A
T
A
C
L
O
S
E
T
A1
3
5
EQ
U
I
P
M
E
N
T
A1
0
1
HA
L
L
W
A
Y
A1
0
5
CL
A
S
S
R
O
O
M
A1
0
6
CO
A
C
H
E
S
O
F
F
I
C
E
A1
0
7
LO
C
K
E
R
S
A1
0
9
BA
T
H
R
O
O
M
A1
0
8
BA
T
H
R
O
O
M
A1
1
2
SH
O
W
E
R
S
A1
1
3
EQ
U
I
P
M
E
N
T
A1
0
2
LA
U
N
D
R
Y
A1
0
3
LO
C
K
E
R
R
O
O
M
A1
1
0
OF
F
I
C
E
A1
1
7
VE
S
T
I
B
U
L
E
A1
1
1
WO
M
E
N
S
/
OF
F
I
C
I
A
L
S
A1
2
0
EL
E
C
T
R
I
C
A
L
A1
1
4
CL
I
N
I
C
A1
3
0
EL
E
V
.
E
Q
P
T
.
A1
3
4
RE
C
O
V
E
R
Y
A1
3
1
BA
T
H
R
O
O
M
A1
3
9
BA
T
H
R
O
O
M
A1
4
0
ST
O
.
A1
2
1
CH
A
N
G
I
N
G
R
O
O
M
A1
1
5
CO
A
C
H
E
S
A1
2
4
CO
R
R
I
D
O
R
/
HA
L
L
W
A
Y
A1
2
3
CO
A
C
H
E
S
'
LO
C
K
E
R
B1
1
8
HE
A
D
C
O
A
C
H
OF
F
I
C
E
B1
1
9
??
WO
M
E
N
S
/
OF
F
I
C
I
A
L
S
BA
T
H
R
O
O
M
A1
1
9
ST
O
R
A
G
E
B1
2
0
VE
S
T
I
B
U
L
E
B1
2
1
BA
T
H
R
O
O
M
B1
1
6
CU
S
T
O
D
I
A
L
B1
2
3
SH
O
W
E
R
S
B1
1
5
HA
L
L
W
A
Y
B1
2
5
LO
C
K
E
R
R
O
O
M
B1
1
4
ME
C
H
A
N
I
C
A
L
B1
1
3
BA
T
H
R
O
O
M
B1
1
0
BA
T
H
R
O
O
M
B1
1
1
PA
S
S
A
G
E
B1
2
4
ME
C
H
A
N
I
C
A
L
B1
0
2
UP
ST-401-EX
ST-400
ST-CO-2
ST-CO-1
ST-102
ST-103
ST-104-EX ST-202
ST-300
ST-301-EX
ST-201
ST-203-EX
ST-104-EX
NEW STWQ
BMP W-1
PR
O
P
E
R
T
Y
L
I
N
E
EXISTING DRY DETENTION BASIN
EXISTING
CONDITIONS
DEVELOPED
CONDITIONS
TOTAL CONTRIBUTING AREA
BOTTOM OF POND ELEVATION
TOP OF BANK ELEVATION
10 YEAR ELEVATION
10 YEAR RELEASE RATE
10 YEAR STORAGE VOLUME
100 YEAR ELEVATION
100 YEAR RELEASE RATE
100 YEAR STORAGE VOLUME
45.26 ac.
797.83
804.65
801.50
4.49 cfs
4.65 ac./ft.
802.65
12.65 cfs
9.91 ac./ft.
45.26 ac.
797.83
ST-TD1
ST-200
100% CONSTRUCTION DOCUMENTS
COPYRIGHT 2024 BY FANNING/HOWEY ASSOCIATES, INC.
WWW.FHAI.COM
ARCHITECT
CONSULTANT
KEY PLAN
BUILDING "A"
BUILDING "B"
A B
SOUTH
SUPPORT
BUILDING
GREYHOUND
ACTIVITIES
CENTER
5201 E Main Street, Carmel, IN 46033
317-844-9961
PROJECT NUMBER: 222154.00
PROJECT ISSUE DATE: 7.26.2024
DRAWN BY: ARS
317.848.0966
350 E NEW YORK ST. SUITE 300, INDIANAPOLIS IN 46204
PROJECT MANAGER: PMR
222154.00
CARMEL HIGH
SCHOOL STADIUM
GRANDSTAND
RENOVATION
PROJECT
CARMEL CLAY SCHOOLS
2390 E. SMOKY ROW (HOME SIDE)
2450 E. SMOKY ROW (VISITOR SIDE)
CARMEL, IN 46032
PLAN
NORTH
REV.
NO.DESCRIPTION DATE
19700317
No.
CITY SUBMITTAL 08-14-20241
50 150050100
INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY
ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR
WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR
EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES
SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND
WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE
OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY
ALL CONSTRUCTION.
THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES,
SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND
CAUTION !!
Know what's below.
before you dig.Call
R
Call 811 or 1-800-382-5544 Before You Begin Any Digging Project.
Call 48 hours or 2 working days before you dig.
It's Fast, It's Easy and It's the Law in the state of Indiana!
SU1.0
OVERALL UTILITY PLAN
SEE DWG SU1.1
UTILITY PLAN -
HOME
GRANDSTAND SEE DWG SU1.2
UTILITY PLAN -
VISITOR
GRANDSTAND
HOME
GRANDSTAND
EXPANSION
1.SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND.
2.TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE
PROVIDED BY CEC CIVIL & ENVIRONMENTAL CONSULTANTS DATED MAY
17, 2022. THE ENGINEER MAKES NO GUARANTEES THAT THE
UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN
THE AREA, EITHER IN SERVICE OR ABANDONED.
3.CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE
PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS,
LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION.
REPORT ANY DISCREPANCIES TO THE ENGINEER.
4.SEE SHEET SU1.1 FOR NEW STORM LATERALS.
5.SEE SHEET SU1.2 FOR NEW SANITARY SEWER LATERAL, FIRE
PROTECTION, DOMESTIC WATER, GAS, ELECTRICAL/POWER AND
TELECOMMUNICATION INFORMATION.
GENERAL NOTES
PROPOSED CHILLED WATER LINE
PROPOSED COMMUNICATION LINE
PROPOSED ELECTRICAL LINE
PROPOSED OVERHEAD ELECTRICAL LINE
PROPOSED UNDERGROUND ELECTRICAL LINE
PROPOSED FIBER OPTIC LINE
PROPOSED FIRE PROTECTION LINE
PROPOSED SANITARY FORCE MAIN
PROPOSED GAS LINE
PROPOSED SANITARY SEWER LINE
PROPOSED STEAM LINE
PROPOSED STORM SEWER LINE
PROPOSED DOWNSPOUT LINE
PROPOSED TELEPHONE LINE
PROPOSED WATER LINE
PROPOSED FIRE HYDRANT
PROPOSED FIRE DEPARTMENT CONNECTION
PROPOSED STORM INLET
PROPOSED STORM MANHOLE
PROPOSED LIGHT POLE
UTILITY LEGEND
APPROXIMATE LIMITS OF CONSTRUCTION
SEE DWG SU1.1
UTILITY PLAN -
HOME STANDS
VISITOR
GRANDSTAND
TAC COMMENTS 10-14-20242
TP
TP
TP
TREE PROTECTION - PER DETAIL F/L1.2
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TP
TPTP
TP
TP
TP
TP
TP