Loading...
HomeMy WebLinkAboutC520 - Site Utility Plan - SAN, WTR, GAS, ELEC, COMM - SU1.2ATS SLDP ATS UP UP UP UP UP UP UP VE S T I B U L E B1 0 7 FI L M B1 0 8 EQ U I P . S T O R A G E B1 1 2 IC E R O O M B1 2 2 CL A S S R O O M B1 0 9 TA B L E S T O R A G E B1 2 6 ME E T I N G A R E A B1 0 1 HA L L W A Y A1 3 7 TR A I N I N G A1 2 9 VE S T I B U L E A1 2 7 FI R E P U M P A1 2 5 WO M E N ' S OF F I C I A L S / MA N A G E R S A1 2 6 CL A S S R O O M A1 2 2 CO R R I D O R A1 2 8 OF F I C E A1 3 8 IT / D A T A C L O S E T A1 3 5 EQ U I P M E N T A1 0 1 HA L L W A Y A1 0 5 CL A S S R O O M A1 0 6 CO A C H E S O F F I C E A1 0 7 LO C K E R S A1 0 9 BA T H R O O M A1 0 8 BA T H R O O M A1 1 2 SH O W E R S A1 1 3 EQ U I P M E N T A1 0 2 LA U N D R Y A1 0 3 LO C K E R R O O M A1 1 0 OF F I C E A1 1 7 VE S T I B U L E A1 1 1 WO M E N S / OF F I C I A L S A1 2 0 EL E C T R I C A L A1 1 4 CL I N I C A1 3 0 EL E V . E Q P T . A1 3 4 RE C O V E R Y A1 3 1 BA T H R O O M A1 3 9 BA T H R O O M A1 4 0 ST O . A1 2 1 CH A N G I N G R O O M A1 1 5 CO A C H E S A1 2 4 CO R R I D O R / HA L L W A Y A1 2 3 CO A C H E S ' LO C K E R B1 1 8 HE A D C O A C H OF F I C E B1 1 9 ?? WO M E N S / OF F I C I A L S BA T H R O O M A1 1 9 ST O R A G E B1 2 0 VE S T I B U L E B1 2 1 BA T H R O O M B1 1 6 CU S T O D I A L B1 2 3 SH O W E R S B1 1 5 HA L L W A Y B1 2 5 LO C K E R R O O M B1 1 4 ME C H A N I C A L B1 1 3 BA T H R O O M B1 1 0 BA T H R O O M B1 1 1 PA S S A G E B1 2 4 ME C H A N I C A L B1 0 2 FDC FDC DRY 4 ST-101 BMP W-1 27 18 19 16 14 3 1 37 27 2 2 3 8 6 8 5 8 5 20 32 33 3 2 3 31 5 21 7 17 12 23 18 23 11 36 35 13 30 34 35 22 ST-CO-2 ST-CO-1 ST-102 ST-103 ST-104-EX ST-202 ST-300 ST-301-EX ST-201 ST-203-EX ST-200 10 25 26 26 25 25 27 29 29 29 15 15 ST-TD1 UTILITY KEYNOTES 1.NEW 6" SANITARY BUILDING LATERAL INVERT ELEV. = 802.20'. COORDINATE PIPE LOCATION, SIZE AND MAERTIAL WITH SHEET P2.01. 2.160' OF 6" PVC SDR-35 PIPE @ 1.04% SLOPE 3.CLEANOUT, PER DETAIL D/SU2.1 4.CONNECT SANITARY LATERAL TO EXISTING MANHOLE @ INVERT ELEV. = 799.00'. SEE DETAIL A/SU2.1 5.NEW 4" PVC C900 DOMESTIC WATER SERVICE LATERAL @ -4' DEPTH (MIN.) TOP OF PIPE ELEV. = 805.00' 6.CONNECT NEW DOMESTIC WATER LINE LATERAL TO EXISTING DOMESTIC LATERAL - COORDINATE WITH MEP DRAWINGS 7.CONNECT NEW 4" DOMESTIC WATER LINE LATERAL TO EXISTING WATER SERVICE LINE AT THIS LOCATION. COORDINATE SHUT-OFF AT NEAREST VALVE. CAP EXISTING LINE TO THE NORTH. 8.PROVIDE PVC C900 FITTINGS WITH THRUST BLOCK AT THIS LOCATION 9.NOTE NOT USED 10.FIRE PROTECTION LATERAL POINT OF CONNECTION. FIELD VERIFY EXISTING PIPE LOCATION, PIPE SIZE, DEPTH AND MATERIAL. 11.FIRE PROTECTION RISER (6" DIP, T/PIPE ELEV. = 799.00') COORDINATE LOCATION AND DEPTH WITH SHEET P2.01 12.FIRE PROTECTION LATERAL, 42' OF 6" DIP. TOP OF PIPE ELEV. = 799.00'. 13.FIRE PROTECTION LATERAL, 12' OF 6" DIP. TOP OF PIPE ELEV. = 799.00' AT NE END SLOPED UP TO 804.00' AT THE WEST END. (FIELD VERIFY EXISTING MAIN ELEVATION) 14.POST INDICATOR VALVE, PER DETAIL F/SU2.4 15.PROVIDE SECTION OF 36" DIA. HDPE AND MARMAC COUPLING FOR DISSIMILAR PIPES (RCP TO HDPE) 16.THRUST BLOCKS, PER DETAIL L/SU2.4 17.NEW FIRE DEPARTMENT CONNECTION (FDC), PER DETAIL J/SU2.4 18.45' OF NEW 4" STEEL FDC LINE. COORDINATE PIPE LOCATION AND DEPTH WITH SHEET P2.01. TOP OF PIPE ELEVATION = 799.00' AT THE BUILDING AND SOUTHWEST AT LOWER CONCOURSE ELEVATIONS. TOP OF PIPE AT THE FDC SHALL BE 805.00'. TOP OF PIPE SHALL HAVE A MINIMUM OF 5' OF COVER. 19.NEW FIRE HYDRANT ASSEMBLY. SEE DETAIL A/SU2.4 20.PROVIDE SECTIONAL VALVE. SEE DETAIL G/SU2.4 21.PROVIDE FLANGED CAP ON FIRE PROTECTION MAIN, 5' NORTH OF THE SECTIONAL VALVE. 22.NEW "DRY" FIRE DEPARTMENT CONNECTION (DRY-FDC), PER DETAIL K/SU2.4. 23.48' OF 4" STEEL "DRY" FDC LINE. COORDINATE PIPE LOCATION, SIZE AND DEPTH WITH SHEET P2.01. TOP OF PIPE ELEVATION = 799.00' AT THE BUILDING AND SOUTHWEST AT LOWER CONCOURSE. TOP OF PIPE ELEVATION AT FDC SHALL BE 805.00'. TOP OF PIPE SHALL HAVE A MINIMUM OF 5' OF COVER. 24.NOT USED 25.FIELD VERIFY LOCATION AND DEPTH OF EXISTING ELECTRICAL LINE. SUPPORT/SHORE DURING CONSTRUCTION OF NEW UTILITY AS REQUIRED. 26.FIELD VERIFY LOCATION AND DEPTH OF EXISTING TELECOMM LINE. SUPPORT/SHORE DURING CONSTRUCTION OF NEW UTILITY AS REQUIRED. 27.APPROXIMATE LOCATION OF EXISTING TELECOMMUNICATIONS LINE. FIELD VERIFY DEPTH OF CONDUIT IS AT -4'-0" BELOW EXISTING GRADES (APPROX. 804.50'±) 28.NOT USED 29.CONTRACTOR TO CLEAN GRAVEL AND DEBRIS FROM THIS STORM PIPE. 30.APPROXIMATE LOCATION OF PROPOSED GAS LINE (TOP OF PIPE ELEVATION SHALL BE AT -3', FIELD VERIFY ACTUAL (DEPTH). 31.CAP EXISTING GAS SERVICE LINE PER GAS COMPANY REQUIREMENTS. 32.TAP EXISTING GAS SERVICE LINE AT THIS LOCATION. (COORDINATE WITH GAS UTILITY COMPANY) 33.NEW GAS SERVICE LINE RE-ROUTED TO RELOCATED (NEW) METER TOP OF PIPE ELEV. = 807.00') 34.NEW GAS SERVICE LINE RE-ROUTED TO RELOCATED (NEW) METER TOP OF PIPE SLOPES FROM ELEV. = 807.00' AT SOUTHWEST TO ELEV. 803.00' AT NORTHEAST) 35.NEW GAS SERVICE LINE RE-ROUTED TO RELOCATED (NEW) METER TOP OF PIPE ELEV. = 803.00') 36.CONNECT NEW GAS METER AND SERVICE TO EXISTING GAS SERVICE LINE AT THIS LOCATION. COORDINATE WITH GAS UTILITY COMPANY. 37.NEW GAS METER, PER GAS UTILITY COMPANY 100% CONSTRUCTION DOCUMENTS COPYRIGHT 2024 BY FANNING/HOWEY ASSOCIATES, INC. WWW.FHAI.COM ARCHITECT CONSULTANT KEY PLAN BUILDING "A" BUILDING "B" A B SOUTH SUPPORT BUILDING GREYHOUND ACTIVITIES CENTER 5201 E Main Street, Carmel, IN 46033 317-844-9961 PROJECT NUMBER: 222154.00 PROJECT ISSUE DATE: 7.26.2024 DRAWN BY: ARS 317.848.0966 350 E NEW YORK ST. SUITE 300, INDIANAPOLIS IN 46204 PROJECT MANAGER: PMR 222154.00 CARMEL HIGH SCHOOL STADIUM GRANDSTAND RENOVATION PROJECT CARMEL CLAY SCHOOLS 2390 E. SMOKY ROW (HOME SIDE) 2450 E. SMOKY ROW (VISITOR SIDE) CARMEL, IN 46032 PLAN NORTH REV. NO.DESCRIPTION DATE 19700317 No. CITY SUBMITTAL 08-14-20241 20 6002040 INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY ALL CONSTRUCTION. THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES, SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND CAUTION !! Know what's below. before you dig.Call R Call 811 or 1-800-382-5544 Before You Begin Any Digging Project. Call 48 hours or 2 working days before you dig. It's Fast, It's Easy and It's the Law in the state of Indiana! SU1.2LEGEND SITE UTILITY PLAN - SANITARY, WATER, GAS, ELECTRIC, COMM. EXISTING COMMUNICATION LINE PROPOSED ELECTRICAL LINE PROPOSED FIRE PROTECTION LINE PROPOSED GAS LINE PROPOSED SANITARY SEWER LINE PROPOSED STORM SEWER LINE PROPOSED WATER LINE PROPOSED FIRE HYDRANT PROPOSED FIRE DEPARTMENT PROPOSED STORM STRUCTURE UTILITY LEGEND PROPOSED POST INDICATOR VALVE SEE SURVEY FOR ADDITIONAL EXISTING LEGEND ITEMS PROPOSED CLEANOUT CONNECTION APPROXIMATE LIMITS OF CONSTRUCTION HOME GRAND STAND FACILITY FFE = 806.36' HOME GRAND STAND GAC SSB DETENTION BASIN 1.SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND. 2.TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE PROVIDED BY CEC CIVIL & ENVIRONMENTAL CONSULTANTS DATED MAY 17, 2022. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN SERVICE OR ABANDONED. 3.CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY DISCREPANCIES TO THE ENGINEER. 4.SEE SHEET SU1.2 FOR NEW SANITARY SEWER LATERAL, FIRE PROTECTION, DOMESTIC WATER, GAS, ELECTRICAL/POWER AND TELECOMMUNICATION INFORMATION. 5.THE PROPOSED STORM SEWER SYSTEM FOR THIS PROJECT WILL BE PRIVATE OWNED. 6.NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED STORM WATER MANAGEMENT PERMIT. 8.UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. 9.DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT. THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE EXISTING CONDITION OF THE RIGHT-OF-WAY. SEE SHEET G0.1 FOR ADDITIONAL INFORMATION ON THE CITY OF CARMEL'S PAVING AND CURB POLICIES. 10.ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF-WAY SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND PROPOSED RIGHT-OF-WAY. 11.CONTRACTOR SHALL CALL CENTERPOINT ENERGY AT 1-800-990-1930 TO CREATE A WORK ORDER TO RELOCATE GAS SERVICE AND METER. GENERAL NOTES ADDENDUM NO. 2 08.23.20242 TAC COMMENTS 10-14-20243 TP TP TP TP TP TP TP T P TP TP TP TP TREE PROTECTION - PER DETAIL F/L1.2