HomeMy WebLinkAboutC530 - Site Utility Plan - SU1.3UP
7 8
9
6
5
6
7
1
3
2
7
7
6
4
6
8
10
9
9
8
ST-901
ST-902
ST-903
8
9
9
10
8
8
9
10
TD
-
V
3
TD
-
V
4
TD
-
V
1
TD
-
V
2
TD
-
V
4
TD
-
V
5
11
11
11
STORM STRUCTURE TABLE
STR.
NO.
TD1
W1
102
103
200
201
202
203-EX
300
301-EX
400
401-EX
STRUCTURE
K1-906
Aqua-Swirl XC-12
Type "C" Manhole
Type "C" Manhole
Inlet Type "A"
Inlet Type "A"
Inlet Type "A"
Existing
Inlet Type "A"
Existing
Type "C" Manhole
Existing
CASTING TYPE
TYPE 465D
Per. Man.
R-1772
R-1772
R-3405
R-3405
R-3405
Existing
R-3405
R-3405
R-3286-8V
Existing
RIM
806.04
808.85
809.68
808.99
806.26
805.75
806.01
805.36
806.21
805.76
813.30
813.46
INCOMING PIPE DATA
(DIRECTION) [FROM STR]
36" HDPE Pipe 802.27 (N) []
12" PVC Pipe 803.41 (E) [CO-2.]
12" RCP 802.73 (N) [102]
6" HDPE Pipe 801.67 (W) []
8" HDPE Pipe 801.67 (N) []
12" HDPE Pipe 801.41 (W) [200]
12" RCP 800.91 (W) [201]
12" RCP 800.39 (N) [202]
6" HDPE Pipe 800.39 (W) []
6" PVC Pipe 803.14 (N) [TD1]
8" HDPE Pipe 803.14 (W) []
12" HDPE Pipe 802.86 (W) [300]
12" RCP 808.44 (W) [400]
OUTGOING PIPE DATA
(DIRECTION) [TO STR]
6" PVC Pipe 803.20 (S) [300]
36" HDPE Pipe 802.27 (S) []
12" RCP 803.31 (S) [103]
15" RCP 802.63 (W) [104-EX]
12" HDPE Pipe 801.57 (E) [201]
12" RCP 801.31 (E) [202]
12" RCP 800.81 (S) [203-EX]
18" RCP 800.29 (E) []
12" HDPE Pipe 803.04 (E) [301-EX]
12" PVC Pipe 802.76 (E) []
12" RCP 808.58 (E) [401-EX]
12" RCP 808.33 (S) []
OUTGOING
PIPE L.F.
11'
8'
115'
48'
33'
53'
56'
3'
37'
2'
28'
3'
OUTGOING
PIPE SIZE
6"
36"
12"
15"
12"
12"
12"
18"
12"
12"
12"
12"
OUTGOING
GRADE
0.49%
0.16%
0.50%
0.55%
0.50%
0.75%
0.75%
0.00%
0.50%
0.00%
0.50%
0.00%
CONNECT TO
STR.
300
103
104-EX
201
202
203-EX
301-EX
401-EX
REMARKS
-
-
-
-
-
-
-
-
-
-
-
100% CONSTRUCTION DOCUMENTS
COPYRIGHT 2024 BY FANNING/HOWEY ASSOCIATES, INC.
WWW.FHAI.COM
ARCHITECT
CONSULTANT
KEY PLAN
BUILDING "A"
BUILDING "B"
A B
SOUTH
SUPPORT
BUILDING
GREYHOUND
ACTIVITIES
CENTER
5201 E Main Street, Carmel, IN 46033
317-844-9961
PROJECT NUMBER: 222154.00
PROJECT ISSUE DATE: 7.26.2024
DRAWN BY: ARS
317.848.0966
350 E NEW YORK ST. SUITE 300, INDIANAPOLIS IN 46204
PROJECT MANAGER: PMR
222154.00
CARMEL HIGH
SCHOOL STADIUM
GRANDSTAND
RENOVATION
PROJECT
CARMEL CLAY SCHOOLS
2390 E. SMOKY ROW (HOME SIDE)
2450 E. SMOKY ROW (VISITOR SIDE)
CARMEL, IN 46032
PLAN
NORTH
REV.
NO.DESCRIPTION DATE
19700317
No.
CITY SUBMITTAL 08-14-20241
20 6002040
INLETS, VALVES, AND MARKS MADE UPON THE GROUND BY
ALSO BE OTHER EXISTING UNDERGROUND UTILITIES FOR
WHICH THERE IS NO ABOVE GROUND EVIDENCE OR FOR
EXACT LOCATIONS OF EXISTING UNDERGROUND UTILITIES
SHALL BE VERIFIED BY CONTRACTOR PRIOR TO ANY AND
WHICH NO ABOVE GROUND EVIDENCE WAS OBSERVED. THE
OTHERS) AND ARE SPECULATIVE IN NATURE. THERE MAY
ALL CONSTRUCTION.
THE LOCATIONS OF ALL EXISTING UNDERGROUND UTILITIES
EVIDENCE (INCLUDING, BUT NOT LIMITED TO, MANHOLES,
SHOWN ON THE PLAN ARE BASED UPON ABOVE GROUND
CAUTION !!
Know what's below.
before you dig.Call
R
Call 811 or 1-800-382-5544 Before You Begin Any Digging Project.
Call 48 hours or 2 working days before you dig.
It's Fast, It's Easy and It's the Law in the state of Indiana!
SU1.3
SITE UTILITY PLAN
LEGEND
UTILITY KEYNOTES
1.32'-6" OF TRENCH DRAIN "TD-V1", PER DETAIL D/G4.3 AND D/SU2.2.
2.32'-6" OF TRENCH DRAIN "TD-V2", PER DETAIL D/G4.3 AND D/SU2.2.
3.RAISE EXISTING STORM STRUCTURE "ST-902" T/RIM ELEV. FROM 805.70'
TO 806.27' WITH PRECAST ADJUSTING RINGS. REPLACE EXISTING
BEE-HIVE GRATE WITH NEENAH R-2540 (OR SIMILAR) FLAT GRATE (FIELD
VERIFY GRATE SIZE). CONNECT NEW 4" PVC PIPES AT INVERT ELEV.
805.00' (NORTH & SOUTH). CONNECT (CORE) NEW 6" DIA. HDPE
UNDERDRAIN AT INVERT ELEV. = 804.00' (EAST).
4.RAISE EXISTING STORM STRUCTURE "ST-901" T/RIM ELEV. FROM 805.80'
TO 806.27' WITH PRECAST ADJUSTING RINGS. REUSE EXISTING GRATE.
CONNECT NEW 6" SLOTTED DRAIN AT INVERT ELEV. 805.00' (NORTH &
SOUTH). CONNECT (CORE) NEW 6" DIA. HDPE UNDERDRAIN AT INVERT
ELEV. = 804.00' (EAST).
5.RAISE EXISTING STORM STRUCTURE "ST-903" T/RIM ELEV. FROM 805.36'
TO 806.27' WITH PRECAST ADJUSTING RINGS. REUSE EXISTING GRATE.
CONNECT (CORE) NEW 6" SLOTTED DRAIN DIA. AT INVERT ELEV. 805.00'
(NORTH & SOUTH). CONNECT (CORE) NEW 6" DIA. HDPE UNDERDRAIN AT
INVERT ELEV. = 804.00' (EAST).
6.25' OF 6" DIA. SLOTTED DRAIN, PER DETAILS B & D/G4.3 AND SHEET SU2.3
7.CLEANOUT, PER DETAIL J/SU2.2. INVERT ELEV. = 805.27'
8.CLEANOUT, PER DETAIL J/SU2.2. INVERT ELEV. = 804.14'
9.28' OF 6" DIA. PERFORATED HDPE UNDERDRAIN PIPE @ 0.50% SLOPE,
PER DETAILS D & E/G4.3
10.PROVIDE HDPE 6" x 6" x 6" TEE-FITTING AND CONNECT TO EXISTING
STORM STRUCTURE
11.CONTRACTOR TO CLEAN GRAVEL AND DEBRIS FROM THIS STORM PIPE.
EXISTING COMMUNICATION LINE
PROPOSED ELECTRICAL LINE
PROPOSED FIRE PROTECTION LINE
PROPOSED GAS LINE
PROPOSED SANITARY SEWER LINE
PROPOSED STORM SEWER LINE
PROPOSED WATER LINE
PROPOSED FIRE HYDRANT
PROPOSED FIRE DEPARTMENT
PROPOSED STORM STRUCTURE
UTILITY LEGEND
PROPOSED POST INDICATOR VALVE
SEE SURVEY FOR ADDITIONAL EXISTING LEGEND ITEMS
PROPOSED CLEANOUT
CONNECTION
APPROXIMATE LIMITS OF CONSTRUCTION
GAC
VISITOR
GRAND STAND
SSB
DETENTION
BASIN
1.SEE DRAWING GD0.1 FOR GENERAL NOTES AND ADDITIONAL LEGEND.
2.TOPOGRAPHIC CONDITIONS AND EXISTING UTILITIES SHOWN WERE
PROVIDED BY CEC CIVIL & ENVIRONMENTAL CONSULTANTS DATED MAY 17,
2022. THE ENGINEER MAKES NO GUARANTEES THAT THE UNDERGROUND
UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, EITHER IN
SERVICE OR ABANDONED.
3.CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS IN THE PROJECT
AREA INCLUDING UNDERGROUND UTILITY CONDITIONS, LOCATION AND
DEPTH PRIOR TO ANY OTHER SITE CONSTRUCTION. REPORT ANY
DISCREPANCIES TO THE ENGINEER.
4.SEE SHEET SU1.2 FOR NEW SANITARY SEWER LATERAL, FIRE PROTECTION,
DOMESTIC WATER, GAS, ELECTRICAL/POWER AND TELECOMMUNICATION
INFORMATION.
5.THE PROPOSED STORM SEWER SYSTEM FOR THIS PROJECT WILL BE
PRIVATE OWNED.
6.NO EARTH DISTURBING ACTIVITY MAY COMMENCE WITHOUT AN APPROVED
STORM WATER MANAGEMENT PERMIT.
8.UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE
RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS
REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH
PROPOSED DEVELOPMENT SHALL BE THE DEVELOPERS RESPONSIBILITY
TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE
RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE.
9.DAMAGE TO THE EXISTING RIGHT-OF-WAY SHALL RESTORED/REPAIRED TO
THE SATISFACTION OF THE CITY AT THE COMPLETION OF THE PROJECT.
THE CONTRACTOR IS ENCOURAGED TO INSPECT THE RIGHT-OF-WAY WITH
THE CITY PRIOR TO THE START OF CONSTRUCTION TO DOCUMENT THE
EXISTING CONDITION OF THE RIGHT-OF-WAY. SEE SHEET G0.1 FOR
ADDITIONAL INFORMATION ON THE CITY OF CARMEL'S PAVING AND CURB
POLICIES.
10.ALL PAVING WITHIN THE EXISTING AND PROPOSED CITY RIGHT -OF-WAY
SHALL CONFORM TO THE REQUIREMENTS OF THE DEPARTMENT OF
ENGINEERING. THE CONTRACTOR SHALL CONTACT THE DEPARTMENT OF
ENGINEERING TO SCHEDULE A PRE-CONSTRUCTION MEETING TO REVIEW
THE DEPARTMENT'S CONSTRUCTION REQUIREMENTS, STAFF
NOTIFICATION REQUIREMENTS, REQUIRED INSPECTIONS FOR CERTAIN
STAGES OF THE WORK AND TO REVIEW THE AUTHORITY OF THE
DEPARTMENT AS IT RELATES TO WORK WITHIN THE EXISTING AND
PROPOSED RIGHT-OF-WAY.
11.CONTRACTOR SHALL CALL CENTERPOINT ENERGY AT 1-800-990-1930 TO
CREATE A WORK ORDER TO RELOCATE GAS SERVICE AND METER.
GENERAL NOTES
NOTE:
1.DIRECTIONAL NOTES FOR PIPES ARE BASED ON TRUE NORTH.
2.ALL STORM SEWER CASTINGS (OPEN LIDS AND SOLID LIDS) SHALL HAVE AN ENVIRONMENTAL LOGO SUCH AS "DUMP NO
WASTE, DRAINS TO WATERWAYS" EMBOSSED (STAMPED) INTO CASTING. IN ADDITION, A SYMBOL OF A FISH SHALL
ALSO BE CAST WITH THE LETTERING. NO "ADD-ON" PLATES OR STICKERS (DECALS) WILL BE PERMITTED.
3.ALL STORM SEWER MANHOLE COVERS SHALL HAVE THE WORDS "STORM SEWER" CAST IN RECESSED LETTERS TWO
INCHES IN HEIGHT.
4.PIPE LENGTHS SHOWN IN THE TABLE ARE TO CENTER OF STRUCTURE.
5.CASTINGS AND FRAMES SHOWN IN TABLE REFER TO NEENAH FOUNDRY MODELS MAY BE SUBSTITUTED WITH AN
APPROVED EQUIVALENT CASTING ONLY WITH ENGINEER APPROVAL.
6.PVC PIPE LISTED IN THE STORM STRUCTURE TABLE SHALL BE SDR-35 UNLESS NOTED OTHERWISE.
STRUCTURE TABLE LEGEND
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
HDPE HIGH DENSITY POLYETHYLENE PIPE (N-12)
ADDENDUM NO. 2 08-23-20242
TAC COMMENTS 10-14-20243
TP
TP TP
TREE PROTECTION - PER DETAIL F/L1.2
TP
TP TP
TP
T
P
TP
TP
TP TP
TP
TP TP
TP
T
P
TP