HomeMy WebLinkAboutA001 - FIRST FLOOR CODE PLAN BUILDING A - A0-01UP
UP
UP
UP UP 222 22
222222222 2
22 22
A101
AC
1
A102
AC
3
A106
EC
18
A107
B
3
A109
L
2
A114
AC
1
A121
AC
1
A115
L
2
A110
L
35
A103
AC
1
A120
L
4
A117
B
2
A118
AC
1
A124
B
9
B120
AC
1
B119
B
3
B114
L
56
B113
AC
1
B118
L
4
B109
EC
38
B123
AC
1
B102
AC
4
A135
AC
1
B101
A3
134
B122
AC
1
B112
AC
1
B108
ES
4
A122
EC
24
A129
EX
19 A130
B
2
A131
B
2
A126
B
2
A125
AC
1
A136
A2
32
A134
AC
1
A138
B
2
B126
AC
1A133
AC
1
CAP
ACT
430
126
CAPACT43026CAPACT43024CAP
ACT
430
193
CAP
ACT
430
1
CAP
ACT
430
1
CAP
ACT
215
38
CAP
ACT
430
1
B107
B110
B111
B124
B125
B116B115
B117
B121
A116
A123
A119
A111
A113
A112
A108
A104
A105
A128
A140A139
A137A127
STUDENT COMMONS
TEAM MEETING AERA
CIRCULATION CORRIDORCIRCULATION CORRIDOR
CAP
ACT
294
1 69
27
21
20
0 5
9
8
24
28
23
23
313255
0
126 193
12.9
AA
AC
12.1
1.1
1.9
BUILDING CODE INFORMATION
1. BUILDING DESCRIPTION:
2. APPLICABLE CODE:
3. BUILDING AREA AND HEIGHT
A. OCCUPANCY/USE GROUP:
B. CONSTRUCTION TYPE:
C. AREA LIMITATION:
D. HEIGHT LIMITATION:
1. HEIGHT MODIFICATIONS:
2. ACTUAL HEIGHT:
4. USE AND OCCUPANCY CLASSIFICATION INDIANA BUILDING CODE
CHAPTER 3:
E -EDUCATION, B -BUSINESS, A2/A3 -ASSEMBLY, A4 - ASSEMBLY
INCIDENTAL USE AREAS INDIANA BUILDING CODE SECTION AND
TABLE 508.2
SMOKE PARTITION & AUTO SPRINKLER SYSTEM
ACCESSORY USE AREAS INDIANA BUILDING CODE SECTION 508.3.1.
ACCESSORY OCCUPANCIES ARE THOSE OCCUPANCIES SUBSIDIARY
TO THE MAIN OCCUPANCY OF THE BUILDING OR PORTION THEREOF.
AGGREGATE ACCESSORY OCCUPANCIES SHALL NOT OCCUPY MORE
THAN 10% OF THE AREA OF THE STORY IN TABLE 503 WITHOUT
HEIGHT AND AREA INCREASES IN ACCORDANCE WITH SECTIONS 504
AND 506 FOR SUCH ACCESSORY OCCUPANCIES (2012
INTERNATIONAL BUILDING CODE)
AREA LIMITATION INDIANA BUILDING CODE SECTION 503
5. TYPE OF CONSTRUCTION INDIANA BUILDING CODE CHAPTER 6 (SEE
TABLE)
TYPE 11B
FIRE SEPARATION DISTANCES INDIANA BUILDING CODE TABLE 602:
REFER TO THE SITE PLAN DRAWINGS FOR LOCATION OF BUILDING(S)
ON SITE; DISTANCES TO CLOSEST INTERIOR LOT LINES; TO THE
CENTER OF A STREET, ALLEY OR PUBLIC WAY; OR TO AN IMAGINARY
LINE BETWEEN TWO BUILDINGS ON THE SAME LOT.
6. FIRE RESISTANCE RATED CONSTRUCTION INDIANA BUILDING CODE
CHAPTER 7:
REFER TO THE CODE PLANS FOR MAXIMUM AREAS OF EXTERIOR
OPENINGS BASED ON THE FIRE SEPARATION DISTANCES.
PENETRATIONS THROUGH FIRE-RESISTANCE-RATED ASSEMBLIES
SHALL BE PROVIDED WITH FIRESTOPPING PER PROJECT MANUAL.
CEILING AND FLOOR OPENINGS THROUGH NON-FIRE-RESISTANCE-
RATED ASSEMBLIES SHALL BE PROVIDED WITH FIREBLOCKING PER
PROJECT MANUAL.
7. INTERIOR FINISHES TO COMPLY WITH INDIANA BUILDING CODE
CHAPTER 8
8. FIRE PROTECTION SYSTEMS INDIANA BUILDING CODE CHAPTER 9:
THE ENTIRE BUILDING, INCLUDING PRESSBOX SHALL BE PROVIDED WITH AN
AUTOMATIC SPRINKLER SYSTEM. REFER TO FIRE PROTECTION DRAWINGS.
9. MEANS OF EGRESS INDIANA BUILDING CODE CHAPTER 10:
THE MEANS OF EGRESS REQUIREMENTS SHALL BE DETERMINED BY
THE ACTUAL OR COMPUTED NUMBER OF OCCUPANTS WHICHEVER
IS THE LARGEST NUMBER. REFER TO THE CODE PLANS FOR ROOM
OCCUPANT LOADS. AREAS OR ROOMS WITH 50 OR MORE
OCCUPANTS SHALL BE PROVIDED WITH TWO OR MORE MEANS OF
EGRESS; 500 OR MORE OCCUPANTS SHALL BE PROVIDED WITH
THREE OR MORE MEANS OF EGRESS; AND 1000 OR MORE
OCCUPANTS SHALL BE PROVIDED WITH FOUR OR MORE MEANS OF
EGRESS.
10.STRUCTURAL DESIGN LOADS:
REFER TO STRUCTURAL DRAWINGS FOR CODE REQUIREMENTS
EDUCATIONAL USED BY 9-12 SCHOOL
2012 INTERNATIONAL BUILDING CODE -
INDIANA BUILDING CODE, 2014 EDITION
(675 IAC 13-2.6)
2012 INTERNATIONAL FIRE CODE -
INDIANA FIRE CODE, 2014 EDITION (675
IAC 22-2)
2012 INTERNATIONAL MECHANICAL
CODE - INDIANA MECHANICAL CODE,
2014 EDITION (675 IAC 18-1.6)
2012 INTERNATIONAL PLUMBING CODE -
INDIANA PLUMBING CODE, 2012 EDITION
(675 IAC 16-1.4)
2012 INTERNATIONAL ELECTRICAL
CODE - INDIANA ELECTRICAL CODE, 2009
EDITION [NFPA 70-2008] (675 IAC 17-1.8)
INDIANA ENERGY CONSERVATION CODE
2010 [ASHRAE 90.1, 2007 AMENDED] (672
IAC 19-4)
2010 ADA STANDARDS FOR ACCESSIBLE
DESIGN
A2, COMMONS
A3, MEETING AREA
A5, GRANDSTAND
B, ADMINISTRATION
E NON SEPARATED
USES (302.1)
11B (601)
UNLIMITED NEW RENOVATION
4 STORY, 55'-0" (TABLE 503)
5 STORY, 75'-0" (504.2)
4 STORY, 72'-0"
STADIUM BUILDING DESIGNED FOR:
200 STUDENTS AND 30 STAFF
CALCULATED MAXIMUM OCCUPANT LOAD45
OCCUPANCY CLASS ABBREVIATIONAC
STADIUM SEATING: SEE A0.03 FOR CAPACITYOUTSIDE AIR FILM
ROOF MEMBRANE
AIR BARRIER
COVER BOARD
ROOF INSULATION
(2 LAYERS)
1 1/2" METAL DECK
INSIDE AIR FILM
TYPICAL LOW SLOPE ROOF ASSEMBLY
VAPOR RETARDER
R VALUE
0.17
0.50
0.45
22.50
0.00
0.00
0.68
R = 24.75
U = 1/R = 0.040
TYPICAL EXTERIOR WALL ASSEMBLY (6" METAL STUD / METAL
WALL PANEL)
EXACT COMPOSITION MAY VARY BASED ON AIR BARRIER/INSULATION SYSTEM
SELECTED
DASHED LINE INDICATES
AIR BARRIER
OUTSIDE AIR FILM
METAL WALL PANEL
PLYWOOD FACED FOAM
INSULATION/SHEATHING (3.1")
INSIDE AIR FILM
R VALUE
0.00
0.17
0.00
16.1
0.68
R = 17.35
U = 1/R = 0.058
5/8" GWB (WHERE
APPLICABLE)
0.00
5/8" GLASS MAT SHEATHING .40
TYPICAL EXTERIOR SOFFIT AND FLOOR ASSEMBLY
EXACT COMPOSITION MAY VARY BASED ON AIR BARRIER/INSULATION SYSTEM
SELECTED
OUTSIDE AIR FILM
DEFS
R VALUE
0.00
0.17
0.00
30.0
0.4
5/8" GLASS MAT SHEATHING .40
CONCRETE SLAB ON METAL DECK
INSIDE AIR FILM 0.68
R = 31.65
U = 1/R = 0.032
U MAX 0.038 Steel Joist Floor
u 0.064 MAX
u 0.048 MAX
TYPICAL EXTERIOR CAVITY WALL ASSEMBLY (8" CMU)
EXACT COMPOSITION MAY VARY BASED ON AIR BARRIER/INSULATION SYSTEM
SELECTED
DASHED LINE INDICATES
AIR BARRIER
OUTSIDE AIR FILM
4" BRICK VENEER
AIR SPACE
2 1/8" CAVITY WALL
INSULATION
8" CMU
INSIDE AIR FILM
R VALUE
0.00
0.17
0.44
1.14
12.0
1.11
0.68
R = 17.04
U = 1/R = 0.059
TYPICAL EXTERIOR WALL ASSEMBLY (6" METAL STUD / BRICK
WALL PANEL)
EXACT COMPOSITION MAY VARY BASED ON AIR BARRIER/INSULATION SYSTEM
SELECTED
DASHED LINE INDICATES
AIR BARRIER
OUTSIDE AIR FILM
INSIDE AIR FILM
R VALUE
0.00
0.17
0.68
R = 20.19
U = 1/R = 0.050
5/8" GWB
6" METAL STUDS 0.00
.56
5/8" GLASS MAT SHEATHING .40
4" BRICK VENEER
AIR SPACE
3" CAVITY WALL INSULATION
0.44
1.14
16.8
TYPICAL EXTERIOR WALL ASSEMBLY (8" CMU / METAL
WALL PANEL)
EXACT COMPOSITION MAY VARY BASED ON AIR BARRIER/INSULATION SYSTEM
SELECTED
DASHED LINE INDICATES
AIR BARRIER
OUTSIDE AIR FILM
12" CMU
INSIDE AIR FILM
R VALUE
0.00
0.17
1.23
0.68
R = 18.18
U = 1/R = 0.55
PLYWOOD FACED FOAM
INSULATION/SHEATHING (3.1")16.1
u 0.064 MAX
u 0.064 MAXu 0.064 MAX
METAL PANEL SIDING 0.00
BATT INSULATION ON TOP OF
FRAMING
VAPOR-PERMEABLE, FLUID-APPLIED
MEMBRANE AIR BARRIER
CODE PLAN LEGEND
FIRE WALLS TO EXTEND 30" ABOVE THE ROOF OR EXTEND TO THE BOTTOM OF A NON-COMBUSTIBLE ROOF DECK
INDICATES 2 HOUR FIRE-RESISTANT RATED FIRE WALL WITH 1-1/2 HOUR RATED OPENING
PROTECTIVES, SECTION 706
COPYRIGHT 2024 BY FANNING/HOWEY ASSOCIATES, INC.
KEY PLAN
WWW.FHAI.COM
ARCHITECT
BUILDING "A"
BUILDING "B"
A B
SOUTH
SUPPORT
BUILDING
GREYHOUND
ACTIVITIES
CENTER
5201 E Main Street, Carmel, IN 46033
317-844-9961
8/13/2024 9:34:04 AM\\data1\citrixprofiles$\tvaughn\my documents\2023_ARCH_222154.02_tpvaughn.rvtPROJECT NUMBER: 222154.00
222154.00
CARMEL HIGH
SCHOOL STADIUM
GRANDSTAND
RENOVATION
PROJECT
CARMEL CLAY SCHOOLS
2390 E. SMOKY ROW (HOME SIDE)
2450 E. SMOKY ROW (VISITOR SIDE)
CARMEL, IN 46032
FIRST FLOOR CODE PLAN BUILDING
A
A0.01
PROJECT ISSUE DATE: 8.13.2024
TAC SUBMITTAL
DRAWN BY: TPV / CJK
317.848.0966
350 E NEW YORK ST. SUITE 300, INDIANAPOLIS IN 46204
PROJECT MANAGER: MKS
ROOM LEGEND - FIRST FLOOR - UNIT A
ROOM NO. ROOM NAME AREA (SF)
A101 EQUIPMENT 256 SF
A102 EQUIPMENT 806 SF
A103 LAUNDRY 247 SF
A104 VESTIBULE 78 SF
A105 HALLWAY 237 SF
A106 CLASSROOM 358 SF
A107 COACHES OFFICE 277 SF
A108 RESTROOM 74 SF
A109 LOCKERS 88 SF
A110 LOCKER ROOM 1749 SF
A111 VESTIBULE 111 SF
A112 BOYS 270 SF
A113 SHOWERS 96 SF
A114 ELECTRICAL 239 SF
A115 CHANGING ROOM 71 SF
A116 CORRIDOR 528 SF
A117 OFFICE 111 SF
A118 STORAGE 29 SF
A119 WOMEN 78 SF
A120 WOMENS/ OFFICIALS 124 SF
A121 STORAGE 122 SF
A122 CLASSROOM 477 SF
A123 CORRIDOR/ HALLWAY 528 SF
A124 COACHES 809 SF
A125 FIRE PUMP 160 SF
A126 WOMEN'S OFFICIALS/ MANAGERS 153 SF
A127 VESTIBULE 103 SF
A128 CORRIDOR 296 SF
A129 TRAINING 895 SF
A130 CLINIC 142 SF
A131 RECOVERY 163 SF
A133 STORAGE 102 SF
A134 ELEV. EQPT. 59 SF
A135 IT/DATA CLOSET 48 SF
A136 STUDENT COMMONS 796 SF
A137 HALLWAY 1507 SF
A138 OFFICE 163 SF
A139 RESTROOM 82 SF
A140 RESTROOM 82 SF
PLAN
NORTH
SCALE: 3/32" = 1'-0"
1 - FIRST FLOOR - CODE PLAN BUILDING A
ROOM LEGEND - FIRST FLOOR - UNIT B
ROOM NO. ROOM NAME AREA (SF)
B101 MEETING AREA 2377 SF
B102 MECHANICAL 966 SF
B107 VESTIBULE 75 SF
B108 FILM 191 SF
B109 CLASSROOM 744 SF
B110 RESTROOM 42 SF
B111 RESTROOM 42 SF
B112 EQUIP. STORAGE 159 SF
B113 MECHANICAL 285 SF
B114 LOCKER ROOM 2752 SF
B115 SHOWERS 95 SF
B116 RESTROOM 264 SF
B117 RESTROOM 101 SF
B118 COACHES' LOCKER 187 SF
B119 HEAD COACH OFFICE 230 SF
B120 STORAGE 109 SF
B121 VESTIBULE 111 SF
B122 ICE ROOM 93 SF
B123 CUSTODIAL 79 SF
B124 PASSAGE 50 SF
B125 HALLWAY 63 SF
B126 TABLE STORAGE 225 SF
FIRST FLOOR 24751 SF
SECOND FLOOR / CONCOURSE 6702 SF
PRESS BOX LEVEL 1 (NEW) 2034 SF
PRESS BOX LEVEL 2 (NEW) 2042 SF
SCALE: 3/4" = 1'-0"
A000 - ROOF/WALL ASSEMBLIES
OCCUPANCY CLASSIFICATION - KEY
Class
Abbreviation Classification Area Per Occupant
Occupancy Gross or
Net
A1 A1 - Assembly With Fixed Seats
A2 A2 - Assembly Without Fixed Seats - Unconcentrated (Tables and Chairs) 15 SF Net
A3 A3 - Assembly Without Fixed Seats - Concentrated (Chairs Only - Not Fixed) 7 SF Net
A4 A4 - Assembly Without Fixed Seats - Standing Space 5 SF Net
AC AC - Accessory Storage Areas, Mechanical Equipment Rooms 300 SF Gross
B B - Business Areas 100 SF Gross
CB CB - Concentrated Business Use Area 50 SF Gross
CR CR - Courtrooms - (Other than fixed seating area)40 SF Net
DC DC - Day Care 35 SF Net
EC EC - Educational - Classroom Areas 20 SF Net
ES ES - Educational - Shops and other Vocational Room Areas 50 SF Net
EX EX - Exercise Rooms 50 SF Gross
KIT KIT - Kitchens - commercial 200 SF Gross
L L - Locker Rooms 50 SF Gross
LR LR - Library - Reading Rooms 50 SF Net
LS LS - Library - Stack Areas 100 SF Gross
MBF MBF - Mercantile - Basement and grade Floor Areas 30 SF Gross
U U - Unoccupied - Corridors (Not Shown) 0 SF Gross
2034 0
2042 0
NOTE::
AT THE UNDERSIDE OF THE GRANDSTAND BLEACHERS
WE HAVE MAINTAINED THE 1 HOUR HORIZONTAL BARRIER
5106
1464510106
1596
REV.
NO.DESCRIPTION DATE